digital cameras by soft imaging system f-viewii

2
Digital Solutions for Imaging and Microscopy Soft Imaging System Digital Solutions for Imaging and Microscopy Soft Imaging System Digital Solutions for Imaging and Microscopy Soft Imaging System Specifications resolution: 1376 x 1032 binning: 2x, 4x, 8x cell size: 6.45 x 6.45 m 2 effective area: 8.9 x 6.7 mm 2 pixel clock rate: 20 MHz dynamic range: 12 bit exposure time: 100 s to 160 s frame rate*: > 22 frames/sec @ 2x binning cooling element: Peltier-Cooling, 10 °C @ 25 °C ambient temperature monitor: CCD chip & housing temperature stabilized: Yes, ± 0.5°C readout noise: < 2 counts non linearity: < 0.6% anti-blooming: > 300 dimensions: 100 x 85 x 50 mm 3 weight: 570 g camera mount: standard C-mount firmware: Flash EEPROM PC interface: FireWire™ (IEEE 1394) Optional: Depending on options, analySIS ® expansion level and camera: Real-time automatic contrast control Real-time shading correction Real-time sharpness monitor Real-time histogram display Real-time FFT computation and display * Camera test conducted on a typical dual CPU PC configuration. The camera resolution setting and the speed of the PC used will directly affect the frame rate. Digital cameras by Soft Imaging System The F-View II is a 12-bit CCD monochrome camera. It is ideal for applications that require extremely high sensitivity, low noise, high-resolution and quantifiable images. The F-View II is Peltier-cooled, powered by FireWire technology™ (IEEE 1394) and is specially designed for FISH or fluorescence applications which require multiple exposures with single band-pass filters. The F-View II is fully integrated into the analySIS ® image analytical software. A growing family! Digital cameras by Soft Imaging System. Observatory for the microcosmos! FVII_11_1_4_3 Take advantage of F-View II's full integration into analySIS ® Real-time functions F-View II is fast. Put this in combination with the high speed of today's CPU's, and you've got an attractively broad range of real-time functions within analySIS ® available to you. These include automatic contrast control, sharpness monitoring and histogram display. Analyzing images A vast library of text, graphic and editing functions is available for labeling images. Special filters and professional particle analysis assist in more extensive investigation of images. All this makes it simple to obtain reliable and reproducible results quickly. No more darkroom Photo-quality printouts can be obtained following acquisition without any need for a darkroom nor its developing chemicals. And these photo-quality printouts are in your hands in minutes. F-View II and analySIS ® Giving you the tools from tomorrow for the tasks of today! Automatic report generation Now you can produce multi-page reports quickly and efficiently. Select multiple images in the image database and insert them all into the report via a single command. In addition to the images themselves, you can have information from any database field automatically included in reports. Automatic scaling, detail zooms, and more – all available to optimize the way you work with images. All documents generated using the analySIS ® software can be inserted into reports. Use the report generator to print out images, related measurement sheets, and diagrams – all on the same page. This report generator provides you with the utmost flexibility for page layout and design. You set up your own templates exactly the way you want them to be. Templates need to be created just once. Templates are what your reports are based on and ensure that the appearance of your documents is uniform. Use the RTF Export function to export your reports to MS Word for continued editing. Archiving analySIS ® offers you a powerful, fully network-able, image-archiving system that handles all the images and data generated during the process of image acquisition and documentation. Images can be stored along with text, sheets and other graphics as records for complete documentation of tasks and processing steps. Input, display and query masks can be defined independently. © 2002, Soft Imaging System GmbH. We are constantly improving our products, thus all specifications are subject to change without notice. The analySIS ® logo is a trademark of Soft Imaging System GmbH. Windows 95, Windows 98, Windows NT, Windows 2000 and Windows XP are trademarks of Microsoft Corp. Europe Soft Imaging System GmbH Johann-Krane-Weg 39 D-48149 Münster Germany Phone: +49 (251) 79800-0 Fax: +49 (251) 79800-99 North America Soft Imaging System Corp. 12596 W. Bayaud Ave.- Suite 300 Lakewood, CO 80228, USA Phone: +1 (303) 234-9270 and (888) FIND SIS Fax: +1 (303) 234-9271 Asia / Pacific Soft Imaging System Sdn Bhd Jalan Usahawan S10E, 2nd Floor, 2320 Century Square 63000 Cyberjaya, Malaysia Phone: +60 (3) 8318-1400 Fax: +60 (3) 8318-1411 Online e-mail: [email protected] Website www.soft-imaging.net a) Her2 gene (Spectrum Orange), b) DNA (DAPI), c) Chromosome (Spectrum Green), d) Combination with mFip Specimen: Norbert Wey, University Zürich, Department of Pathology, Switzerland d c a b FireWire™ fluorescence camera F-View II F-View II

Upload: others

Post on 03-Feb-2022

35 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Digital cameras by Soft Imaging System F-ViewII

Digital Solutions for Imaging and Microscopy

Soft Imaging System

Digital Solutions for Imaging and Microscopy

Soft Imaging SystemDigital Solutions for Imaging and Microscopy

Soft Imaging System

Specificationsresolution: 1376 x 1032binning: 2x, 4x, 8xcell size: 6.45 x 6.45 µm2

effective area: 8.9 x 6.7 mm2

pixel clock rate: 20 MHzdynamic range: 12 bitexposure time: 100 µs to 160 sframe rate*: > 22 frames/sec @ 2x binningcooling element: Peltier-Cooling, 10 °C @ 25 °C ambienttemperature monitor: CCD chip & housingtemperature stabilized: Yes, ± 0.5°Creadout noise: < 2 countsnon linearity: < 0.6%anti-blooming: > 300dimensions: 100 x 85 x 50 mm3

weight: 570 gcamera mount: standard C-mountfirmware: Flash EEPROMPC interface: FireWire™ (IEEE 1394)

Optional:Depending on options, analySIS® expansion level and camera:

Real-time automatic contrast controlReal-time shading correctionReal-time sharpness monitorReal-time histogram displayReal-time FFT computation and display

* Camera test conducted on a typical dual CPU PC configuration. The camera resolution setting and the speedof the PC used will directly affect the frame rate.

Digital cameras by Soft Imaging System

The F-View II is a 12-bit CCD monochrome camera.It is ideal for applications that require extremelyhigh sensitivity, low noise, high-resolution andquantifiable images. The F-View II is Peltier-cooled,powered by FireWire technology™ (IEEE 1394) andis specially designed for FISH or fluorescenceapplications which require multiple exposures withsingle band-pass filters.

The F-View II is fully integrated into the analySIS®

image analytical software.

A growing family!Digital cameras by Soft Imaging System.

Observatory for the microcosmos!

FVII_

11_1

_4_3

Take advantage of F-View II's full integrationinto analySIS®

Real-time functions

F-View II is fast. Put this in combination with the highspeed of today's CPU's, and you've got an attractively broadrange of real-time functions within analySIS® available toyou. These include automatic contrast control, sharpnessmonitoring and histogram display.

Analyzing images

A vast library of text, graphic and editing functions isavailable for labeling images. Special filters and professionalparticle analysis assist in more extensive investigation of

images. All this makes it simple to obtain reliable andreproducible results quickly.

No more darkroom

Photo-quality printouts can be obtained following acquisitionwithout any need for a darkroom nor its developingchemicals. And these photo-quality printouts are in yourhands in minutes.

F-View II and analySIS® –Giving you the tools from tomorrow for the tasksof today!

Automatic report generation

Now you can produce multi-page reports quickly and efficiently. Select multiple imagesin the image database and insert them all into the report via a single command. In additionto the images themselves, you can have information from any database field automaticallyincluded in reports. Automatic scaling, detail zooms, and more – all available to optimizethe way you work with images. All documents generated using the analySIS® softwarecan be inserted into reports. Use the report generator to print out images, relatedmeasurement sheets, and diagrams – all on the same page. This report generator providesyou with the utmost flexibility for page layout and design. You set up your own templatesexactly the way you want them to be. Templates need to be created just once. Templatesare what your reports are based on and ensure that the appearance of your documentsis uniform. Use the RTF Export function to export your reports to MS Word for continuedediting.

Archiving

analySIS® offers you a powerful, fully network-able, image-archivingsystem that handles all the images and data generated during theprocess of image acquisition and documentation. Images can bestored along with text, sheets and other graphics as records forcomplete documentation of tasks and processing steps. Input,display and query masks can be defined independently.

© 2002, Soft Imaging System GmbH. We are constantly improving our products, thus all specifications are subject to change without notice.The analySIS® logo is a trademark of Soft Imaging System GmbH. Windows 95, Windows 98, Windows NT, Windows 2000 and Windows XP are trademarks of Microsoft Corp.

EuropeSoft Imaging System GmbHJohann-Krane-Weg 39D-48149 MünsterGermanyPhone: +49 (251) 79800-0Fax: +49 (251) 79800-99

North AmericaSoft Imaging System Corp.12596 W. Bayaud Ave.- Suite 300Lakewood, CO 80228, USAPhone: +1 (303) 234-9270and (888) FIND SISFax: +1 (303) 234-9271

Asia / PacificSoft Imaging System Sdn BhdJalan UsahawanS10E, 2nd Floor,2320 Century Square63000 Cyberjaya, MalaysiaPhone: +60 (3) 8318-1400Fax: +60 (3) 8318-1411

Onlinee-mail:[email protected]

Websitewww.soft-imaging.net

a) Her2 gene (Spectrum Orange),b) DNA (DAPI),c) Chromosome (Spectrum Green),d) Combination with mFip

Specimen: Norbert Wey, University Zürich,Department of Pathology, Switzerland

d

c

a

b

FireWire™ fluorescence cameraF-ViewIIF-ViewII

Page 2: Digital cameras by Soft Imaging System F-ViewII

Digital Solutions for Imaging and Microscopy

Soft Imaging System

F-View II's integration into analySIS® provides all thecapabilities and advantages of state-of-the-art digitalimage processing and analysis, ranging from imagelabeling, archiving, report generation and e-mailing,as well as photo-realistic printouts without thedarkroom.

Soft Imaging System's digital cameras are designedto meet the steadily rising demands on digital imageacquisition for all areas of microscopy. And so is thenewly developed 12-bit, cooled CCD color cameraF-View II, our latest 12-bit, Peltier-cooled, FireWire™-driven solution for fluorescence microscopy.

All camera functions are fully controlled by the analySIS®

image-processing software. Real-time functions enablethe use of the entire dynamic range under all conditionsand guarantee the best contrast.

High Resolution

The CCD chip of the F-View II has 1376 x 1032 pixelresolution. The 12-bit dynamic range means that evenacquisition of images with very bright and faint regionsis dynamically optimal.

High sensitivity

CCD elements are so sensitive that they have no troubledetecting even the weakest of signals. The electronicshutter offers variable exposure times ranging from100 µs to 160 s.

High frame rate

The high speed ADC (Analog-Digital Converter) workingat a clock rate of 20 MHz in full 12-bit dynamic rangeis able to perform double sampling even at a readout

rate of 20 MHz. Various frame rates are supported bythis camera. For example, the camera can be set toacquire at a high frame rate of more than 22 fps atTV resolution using 2x binning. View your zoomed-insample, locate the area of interest and focus – allconveniently onscreen. No longer are you forced totrade off speed for quality. For acquisition the systemswitches automatically into the high-resolution mode.This avoids bleaching of your fluorescence specimenand offers optimal performance when settingparameters.

FireWire™ Interface (IEEE 1394)

FireWire™ technology guarantees that the F-View IIinstallation is easy on any PC or laptop equipped witha FireWire™ port. The days when you were limited to

a frame grabber and just a single camera are history.FireWire™ technology enables you to use multiplecameras on the same PC.

Peltier-Cooling

Image noise is generally the result of the CCD chip notbeing cooled to a low enough temperature (“darkcurrent”). For the F-View II, thermal noise is not aproblem because the CCD chip is Peltier-cooled andstabilized at 10°C. Noise is further suppressed by theapplication of a highly efficient readout techniqueknown as Correlated Double Sampling (CDS).

Compact design

With its elegantly compact, newly designed housing,the F-View II can be mounted onto all light microscopeswith a C-mount adaptor. No other interfaces or adaptorsare necessary. Plus, you only need one cable for gettingdata and power to the PC's FireWire™ port. No moreclutter and no 'octopus' of cables getting in your way.

Digital Solutions - Developed to be exceptional!

FireWire™ fluorescence cameraF-ViewIIF-ViewII

DAPI, PE, APC, PerCP & FITC image acquisitionsof stem cells: combined acquisitions done via the mFipanalySIS® module

source: Dr. Hans WesselsUniversity Clinic for Children, Tübingen, Germany

characterization of CCD chip used