digimatic atex approved, capacitance level sensor · datasheet no:-d5230a atex & iecex...

2
Datasheet No:-D5230A ATEX & IECEx Approved, Auto-calibrating, Fixed Point Level sensor DIGIMATIC DML4AI II 1 (1)D Ex ta[ia] IIIC T100°C Da IP65 Tamb= -20°C to +50°C DIGIMATIC ATEX Approved, Capacitance Level sensor Walsall Road, Norton Canes, Cannock, Staffordshire, England. WS11 9TB Tel: (01543) 277003 Fax: (01543) 271217 Web: www.synatel.co.uk e-mail: sales@ synatel.co.uk ® DIMENSIONS A certified, automatic calibration level control for use in liquids, solids and powders. TRAC11ATEX11268X IECEx TRC 12.0016X II 1 (1)D Ex tD[iaD] A20 IIIB T100°C Da IP65 Tamb= -20°C to +50°C The Digimatic incorporates a microprocessor which automatically calibrates the unit to suit both the vessel and range of material in which it is used. Automatic calibration is carried out simply by pressing one button with the probe uncovered and a second when covered. The unit can be recalibrated as required. In the manual mode, the same buttons are used to raise or lower the sensitiv- ity. A 4 digit LED displays shows set values of uncovered, covered and trip ATEX & IECEx approved for Dust Hazard Area use. Membrane keypad for calibration purposes. Automatic or manual calibration "Power shield" material build up compensation Adjustable time delay P Power Shield 110/230V ac 240V ac 3A 100 Conduit entry tapped 20mm External ground connection Blind conduit entry tapped 20mm. Drill out to use. 1" BSP taper mounting thread Power shield cover must protrude into container as far as possible, and at least 6mm. 144 ? 4x Stainless steel captive fixing screws SYNATEL 132 DIGIMATIC A Automatic 24V dc settings, during calibration, and measured values during normal use. The display is also used to show any time interval which may have been programmed. The Digimatic incorporates a "power shield" to overcome the effects of sticky or viscous materials adhering to the probe allowing it to respond only to a genuine covered condition. A range of probe rods are available in solid stainless steel or wire rope in lengths up to 10 metres The Digimatic is suitable for both top or side entry and operation is from 110/230V AC or 24V dc supplies. SYNATEL

Upload: others

Post on 06-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DIGIMATIC ATEX Approved, Capacitance Level sensor · Datasheet No:-D5230A ATEX & IECEx Approved, Auto-calibrating, Fixed Point Level sensor DIGIMATIC DML4AI II 1 (1)D Ex ta[ia] IIIC

Datasheet No:-D5230A

ATEX & IECEx Approved,Auto-calibrating, Fixed Point

Level sensorDIGIMATIC DML4AI

II 1 (1)D Ex ta[ia] IIICT100°C Da IP65 Tamb= -20°C to +50°C

DIGIMATIC ATEX Approved, Capacitance Level sensor

Walsall Road, Norton Canes, Cannock,Staffordshire, England. WS11 9TBTel: (01543) 277003 Fax: (01543) 271217

Web: www.synatel.co.uke-mail: sales@ synatel.co.uk

®

DIMENSIONS

A certified, automatic calibrationlevel control for use in liquids,solids and powders.TRAC11ATEX11268X IECEx TRC 12.0016X

II 1 (1)D Ex tD[iaD] A20 IIIB T100°CDa IP65 Tamb= -20°C to +50°C

The Digimatic incorporates amicroprocessor which automaticallycalibrates the unit to suit both thevessel and range of material inwhich it is used.

Automatic calibration is carried outsimply by pressing one button withthe probe uncovered and a secondwhen covered. The unit can berecalibrated as required. In themanual mode, the same buttons areused to raise or lower the sensitiv-ity.

A 4 digit LED displays shows setvalues of uncovered, covered and trip

ATEX & IECEx approved for DustHazard Area use.

Membrane keypad forcalibration purposes.

Automatic or manual calibration

"Power shield" material buildup compensation

Adjustable time delay

PPower Shield

110/230V ac 240V ac 3A

100

Conduit entry tapped 20mm

External ground connection

Blind conduit entry tapped 20mm.Drill out to use.

1" BSP taper mounting thread

Power shield cover must protrude intocontainer as far as possible, and at least 6mm.

144?

4x Stainless steel captive fixing screws

SYNATEL

132

DIGIMATIC

AAutomatic24V dc

settings, during calibration, andmeasured values during normal use.The display is also used to show anytime interval which may have beenprogrammed.

The Digimatic incorporates a"power shield" to overcome theeffects of sticky or viscous materialsadhering to the probe allowing it torespond only to a genuine coveredcondition.

A range of probe rods are availablein solid stainless steel or wire ropein lengths up to 10 metres

The Digimatic is suitable for bothtop or side entry and operation isfrom 110/230V AC or 24V dcsupplies.

SYNATEL

Page 2: DIGIMATIC ATEX Approved, Capacitance Level sensor · Datasheet No:-D5230A ATEX & IECEx Approved, Auto-calibrating, Fixed Point Level sensor DIGIMATIC DML4AI II 1 (1)D Ex ta[ia] IIIC

xxx-xxx >:D5230(A)E.A.O.E.SYNATEL©:We reserve the right to alter specifications without prior notification.

SPECIFICATION

CONNECTIONS

CLASSIFICATION II 1 (1)D Ex ta[iaD] IIIC T100°C Da IP65 Tamb= -20°C to +50°C

SUPPLY 115/230 V ac 50/60Hz.and 24V dc (stabilised).

DC SUPPLY TOLERANCE -6.0%.to+2%.

SUPPLY CABLE SIZE Min: 1 sq.mm Max: 4 sq.mm

SUPPLY CABLE FUSE/Cct BREAKER(max rating): 5A

LOAD 1.5VA. max ac, 50mA max dc.

AMBIENT TEMPERATURE -10°C to +50°C.

SENSITIVITY 0.5 picofarad.

OUTPUT 1 set of volt free relay change-over contacts rated at 2.5A 240 V ac non-inductive.

OUTPUT MODE High or low level, selected by a switch.

CALIBRATION Automatic or manual calibration using independent push buttons for covered anduncovered conditions.

DISPLAY LED display used for calibration purpose and timer setting.

TIME DELAY Adjustable via single pushbutton, 0-128 seconds delay on material arriving and leaving.

INDICATORS LEDs show power, probe covered and calibrating.

BUILD -UP Power shield automatic compensation for material build-up on the probe.

CABLE ENTRY 20mm conduit entry.

MOUNTING Via 1" B.S.P Parallel thread.

CONNECTIONS Screw terminal block.

PROBE Stainless steel. In 10cm, 1m, 2m rod or 10m wire rope.

ENCLOSURE Flame retardant, glass filled nylon enclosure. (Modified polyamide 66).

PROTECTION IP65.

WEIGHT DML4AI 2Kg

10cm rod 250g1 metre rod 1.5Kg2 metre rod 3Kg10 metre wire rope 1.25Kg

Probe Description Order Code

822-006

822-003

HOW TO ORDER:-1. Order Digimatic DML4AI.2. Order probe required (see chart)

10cm StainlessSteel Rod

1 metre StainlessSteel Rod

2 metre StainlessSteel Rod

10 metre StainlessSteel Wire Rope

822-004

823-004

DUST HAZARD APPROVAL:ATEX, Category 1, Dust,

Temperature T100°C.

EarthBond

EN

110v

24v0v230v

NOTE: A SUPPLY EARTH IS ESSENTIAL & MUST BE BONDED TO CONTAINER METAL WORK!