dibujos compresores 2010 (2)
DESCRIPTION
manual de instalacionTRANSCRIPT
-
DO NOTSCALE PRINT
FRIST USED ON
OR
MATL.SIZE
CSCALE WT.
DWG. NO.
WP 1907
REV.
E
TITLE DIAGRAM. WIRING. I I . A . T . KIT
NAME DATE
DR. CARLEY 3/97
3/97
CX.
APPD. CARLEY
DATEISSUED_________________________________
APPD.BY_____________________________________
SHEET 1 OF 2
UNLESS OTHERWISE SPECIFIED
COLTE INDUSTRIES
TOLERANCE ON ANGLES________TOLERANCE ON 2 PLACE DMS___TOLERANCE ON 3 PLACE DMS___FINISH ON MANCHED BUFACES____________________
FINISH
DUINCY COMPRESSORDIVISION
1361
NOTES: 1) ALL WIRES ARE RED UNLESS OTHERWISESPECIFIED.
2) DASHED LINES REPRESENT WIRES FOR REMOTE DEVICESAND WIRE SUPPLIED BY OTHERS.
A B C D FE
1
4
7
A B
9
6
3
TO H . A . TPROBE
CONECTION DIAGRAM
BA C D E F
CR CR
CR
START
TO II.A.T PROBE
120 VAC CONTROLPOWER SUPPLY
CR
WP 1739
THE MATERIAL IS CERTIFIQUED AND CONTAINS INFORMATION AND OTHER RIGHTS WICHT ARE THE BOLI AND EXCLUSIVE PROPIERTY OF DUINCY COMPRESOR DIVISION OF COLLEC INDUSTRIE POSETION OF THIS MATERIAL DOES NOT DUINCY COMPRESOR DIVISION ANY RIGHTSTHERE TO AND ANY PRODUCTION LINE COPY AND OFICER OF DUINCY COMPRESOR DIVISION.
INFORMATION OF CITIES INDUSTRIALES INC
-
CAUTION: INSTALLATION NOTES
1) AT INSTALLATION. THE CUSTOMER IS TO PROVIDE DISCONNECT AND BRANCH CIRCUITOVERCURRENT PROTECTION IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODEAND/OR ANY LOCAL CODES HAVING PRECEDENCE.2) GROUNDING: AT INSTALLTION, THE ELECTRICAL CONTROL ENCLOSURE IN ACCORDANCE WITHTHE NATIONAL ELECTRICAL CODE AND/ OR ANY LOCAL CODES HAVING PRECEDENCE.3)FOR CONTROLS OPTIONS SEE SHEET 2 OF 2.4) DASHED LINES REPRESENT WIRES FOR REMOTE DEVICES OR WIRES SUPPLIED BY OTHERS.5) PRESURE SWITCHES MAY BE MOUNTED INSIDE ENCLOSURE.6) ALL WIRES ARE RED UNLEES OTHERWISE SPECIFIED.
DO NOTSCALE PRINT
FRIST USED ON
QRD-25
MATL.SIZE
D
SCALE WT.
DWG. NO.
WP 1907
REV.
E
TITLE
DIAGRAM. WIRING. 3 PHASE. ALTERNATING. DUPLEX
NAME DATE
DR. CARLEY 3/97
3/97
CX.
APPD. CARLEY
DATEISSUED__________________
APPD.BY______________________
SHEET 1 OF 2
UNLESS OTHERWISE SPECIFIED
COLTE INDUSTRIES
TOLERANCE ON ANGLES___TOLERANCE ON 2 PLACE DMS___________________TOLERANCE ON 3 PLACE DMS___________________FINISH ON MANCHED BUFACES________________
FINISH
DUINCY COMPRESSORDIVISION
1361CON.
POS. NO.1 NO.2 AUTO
X O O
O XO
A
B
CONTROLS POWER SUPPLY
120V WITH CONTROLTRANSFORMERS
FU5
FU4
FU2
FU1 FU3
FU3
L3
L2
L1
L3
L2
L1
CPT 2
M1
CPT1
YEL
YEL
YEL
YEL
M2
12
11
1
2
GRN
GRN
COMPRESORMOTOR NO. 1
L1
L2
L3
T3
T2
T1
BLK BLK BLK
OL1
M1
MOTOR CIRCUITOVERCURRENTPROTECTION
SEE NOTE 1 + 2
POWER SUPPLY COMPRESSOR NO. 1
L1
L2
L3
T3
T2
T1
BLK BLK BLK
OL2
M2
MOTOR CIRCUITOVERCURRENTPROTECTION
SEE NOTE 1 + 2
POWER SUPPLY COMPRESSOR NO. 2
COMPRESORMOTOR NO. 2
2
CONTROLS POWER SUPPLY
88 A B
CR1
1
CR2BA 1
1
9M1
13 14
2
2
NO. 1- NO. 2 -AUTO
SSI
77
J5
2
3 4 5 6
6
A2
M1
18
A1 A2
11
1161514
12
12
PS2-B4
13
1413
12M2
J7
12
62
1713
13
6162
M1CR1
PS1-A13 14J3 J4
16
M2
11
JB
9695
OL2
CONTROLS POWER SUPPLY
PS2-A
PS1-A
M2
62615354
M2
2
2
2CR1
5 3
10
2 6
7CR2
11
96
OL1
A1
95
4J1 J2
2
54 53
M1
3
A
B
J6
A
B
C
D1
D2
E
E1
E2 HAT WIRE 6 WAS 5
HAT WIRE 5 WAS 6
SEE SHEET 2 OF 2
ON SHEET I
ADD H . A .T . /. O . L .
SHEETS I AND 2
REVISE WIRE NO . ON
ORIGININAL RELASE
ZONE BTM DESCRIPTION
5045-74 3 /97 PMC
PMC
PMC
PMC
PMC
PMC
PMC
PMC
5044-03
5044-54
5044-54
5044-03
5044-03
5 /97
5 /97
8/87
12/97
12/97
8/87
8/87
5044-54
5043-13
5043-13
5043-13
WP
19
07
THE MATERIAL IS CERTIFIQUED AND CONTAINS INFORMATION AND OTHER RIGHTS WICHT ARE THE BOLI AND EXCLUSIVE PROPIERTY OF DUINCY COMPRESOR DIVISION OF COLLEC INDUSTRIE POSETION OF THIS MATERIAL DOES NOT DUINCY COMPRESOR DIVISION ANY RIGHTSTHERE TO AND ANY PRODUCTION LINE COPY AND OFICER OF DUINCY COMPRESOR DIVISION.
INFORMATION OF CITIES INDUSTRIALES INC
-
2 1 6 5 12 11 16 15
E FDCA B
H.A.T. AND L.O.L SHUTDOWN KITS
NOTE: REMOVE JUMPERS J2 & J4 FROM DUPLEX CONTROL PANEL.
DUPLEX CONTROL PANEL
H.A.T. KIT COMPRESSOR NO. 1TO.H.A.T.PROBE
E FDCA B
H.A.T. KIT COMPRESSOR NO. 2TO.H.A.T.PROBE
CR
CR
START
CR CRCR CR
CR
CR
START
FS1WHT
FS2WHT
BKL BKL6 16
H.A.T. SHUTDOWN KITS
NOTE: REMOVE JUMPER J2 & J4 FROM DUPLEX CONTROL PANEL.DUPLEX CONTROL PANEL
2 61 5
FEDCA B FEDCA B
1611 1512
CR
CR
START
CR
CR
START
H.A.T. KIT COMPRESSOR NO. 2 H.A.T. KIT COMPRESSOR NO. 2TO.H.A.T.PROBE TO.H.A.T.PROBE
CR CRCR CR
1 6 52 12 11 16 15
NOTE: 1 ALL WIRES ARE RED UNLEES OTHERWISE SPECIFIED
DUPLEX CONTROL PANEL
J2 J45 6 1 15 16 11
LOW OIL PRESUSURE SWITCHESNOTE: REMOVE JUMPERS J2 & J4 FROM DUPLEX CONTROL PANEL.
L.OP. SWICTH COMPRESSOR NO.1
2 L M 120
L.OP. SWICTH COMPRESSOR NO.2
2 L M 120
NOTE: REMOVE JUMPERS J2 & J4 FROM DUPLEX CONTROL PANEL.
1 6 5 12 11 16 15
DUPLEX CONTROL PANEL
LOW OIL LEVEL SWITCHES
NOTE: REMOVE JUMPERS J2 & J4 FROM DUPLEX CONTROL PANEL.
5 6 15 6
DUPLEX CONTROL PANEL
BKLWHT
FS1 FS2
WHT BKL
CR6 7
A BPS1
21 LOWPS2
3 4
C D E F
5
8 9 9 10
CR CR
CR
6 7
A BPS1
21 LOWPS2
3 4
C D E F
5
8 9 9 10
CR CR
2
2 1 6 5 12 11 16 15
LOW OIL LEVEL SWICTH COMP. NO. 1 LOW OIL LEVEL SWICTH COMP. NO. 2
ETM 1
6 18
M1OLI 1
6
ETM 2
16 19
M2OLI 2
16
6 18
M1OLI 1
6
16 19
M2OLI 2
16
COMPRESOR ON PILOT LIGHTS
COMPRESSOR ELAPED TIME METERES
R
R
COMP. NO 1ON
COMP. NO 2ON
NOTES: 1) ALL WIRES ARE RED UNLESS OTHERWISE SPECIFIED. 2) DASHED LINES REPRESENT WIRES FOR REMPOTE DEVICES OR WIRES SUPPLIED BY OTHERS.
POWER ON PILOT LIGHTS
COMP. NO . 1POWER ON
G
2 1
2 1
COMP. NO . 2POWER ON
G
2 1
12 11
(REMOVE JUMPERS JI & J31)
14 15
1215
1514
12
4
4
2
25
5
J3
J1
NOTE: FOR USE ONLY WITH UNITS THAT HAVE DUAL- CONTROL.
HAND-OFF-AUTO SWITCHCOMP. NO. 1
HAND- OFF-AUTO
154
4
J1
ON OFF SWITCHES
OFF ON
514
14 5
J3
OFF ON
(REMOVE JUMPERS J1&J3 )
POS.
CONT.
TEST OFF AUTO
X
O
O
O
O
X
X
O
O
O
O
X
C
B
D
TEST-OFF-AUTO SWICHES
COMP. NO 1TEST OFF AUTO
2
4 5
52
4 5JI
COMP. NO 2TEST OFF AUTO
12
14 15
1512
14 15J3
C
B
A
D
(REMOVE JUMPERS JI & J31)
14 15
1215
1514
12
4
4
2
25
5
J3
J1
HAND-OFF-AUTO SWITCHCOMP. NO. 1
HAND- OFF-AUTO
NOTE: FOR USE ONLY WITH UNITS THAT HAVE DUAL- CONTROL.
COMP. NO. 2HAND- OFF-AUTO
DO NOTSCALE PRINT
FRIST USED ON
QRD-25
MATL. SIZE
DSCALE WT.
DWG. NO.
WP 1907
REV.
E
TITLE
DIAGRAM. WIRING. 3 PHASE. ALTERNATING. DUPLEX
NAME DATE
DR. CARLEY 3/97
3/97
CX.
APPD. CARLEY
DATEISSUED
APPD.BY
SHEET 1 OF 2
UNLESS OTHERWISE SPECIFIED
COLTE INDUSTRIES
TOLERANCE ON ANGLES ___TOLERANCE ON 2 PLACE DMS___________________TOLERANCE ON 3 PLACE DMS___________________FINISH ON MANCHED BUFACES________________
FINISH
DUINCY COMPRESSORDIVISION
1361
A
THE MATERIAL IS CERTIFIQUED AND CONTAINS INFORMATION AND OTHER RIGHTS WICHT ARE THE BOLI AND EXCLUSIVE PROPIERTY OF DUINCY COMPRESOR DIVISION OF COLLEC INDUSTRIE POSETION OF THIS MATERIAL DOES NOT DUINCY COMPRESOR DIVISION ANY RIGHTSTHERE TO AND ANY PRODUCTION LINE COPY AND OFICER OF DUINCY COMPRESOR DIVISION.
INFORMATION OF CITIES INDUSTRIALES INC
DIBUJOS COMPRESORES 2010 (2).vsdPgina-1Pgina-2Pgina-3