dhc sizing guide and technical datamodel 1 dhc 3-1 dhc 3-2 dhc 4-2 dhc 4-3 dhc 5-2 dhc 6-2 dhc 8-2...

2
Simply the Best DHC Sizing Guide and Technical Data Simply the Best 17 West St., W. Hatfield, MA 01088 | 800.582.8423 | 413.247.3380 | fax 413.247.3369 | info @ stiebel-eltron-usa.com | www.stiebel-eltron-usa.com 1.0 -2.0 DHC Tankless Electric Water Heater Sizing Guide DHC MODEL Std. Std. High High Non- DHC 3-1 DHC 3-2 DHC 4-2 LAVATORY SINK 0.5 0.5 1.0 1.0 2.0 Flow GPM DHC 4-3 code 2.0 Low Low Std. 1.0 1.0 2.0 Std. 2.0 1.0 -2.0 KITCHEN SINK Utility / Janitor’s Sink DHC 6-2 DHC 8-2 DHC 9-3 DHC 10-2 DHC 5-2 HI AK MB ON QC PE NS NH VT MA CT RI NJ DE MD NB ME NY PA WV VA NC KY TN SC GA MS AL MO AR LA TX FL OH IN IL ID OR WA NE MT WY UT AZ CA NM CO IA MN ND SD NE KS OK MI WI AB SK Cool (Northern) Climate Warm (Southern) Climate BC Inlet water 45°F - 55°F Inlet water 55°F - 70°F These recommendations are for units installed with 240 V service. Increase one model size if unit will be installed with 208 V service. Call Stiebel Eltron at 800.582.8423 if you have any sizing questions, or if you have high flow showers, or another out-of-the-ordinary situation. Stiebel Eltron service representatives can make recommendations on sizing, or provide assistance with our water heaters, to both homeowners and professional installers.

Upload: others

Post on 24-Jan-2021

27 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DHC Sizing Guide and Technical DataModel 1 DHC 3-1 DHC 3-2 DHC 4-2 DHC 4-3 DHC 5-2 DHC 6-2 DHC 8-2 DHC 9-3 DHC 10-2 Item no. 074050 074052 074053 074051 074054 231546 074424 232204

Simply the Best

DHC Sizing Guide and Technical Data

Simply the Best 17 West St., W. Hatfield, MA 01088 | 800.582.8423 | 413.247.3380 | fax 413.247.3369 | [email protected] | www.stiebel-eltron-usa.com

1.0 -2.0

DHC Tankless Electric Water Heater Sizing GuideD H C M O D E L

Std.Std.HighHighNon-

DHC 3-1 DHC 3-2 DHC 4-2

LAV

ATO

RY

SIN

K 0.50.51.01.02.0

Flow GPM DHC 4-3

code 2.0

LowLowStd.

1.01.02.0

Std. 2.0

1.0 -2.0

KIT

CHEN

SIN

K

Utility /Janitor’sSink

DHC 6-2 DHC 8-2 DHC 9-3 DHC 10-2DHC 5-2

HI

AK

MBON QC

PE

NS

NHVT

MA

CTRI

NJDE

MD

NB

ME

NY

PA

WV VA

NCKY

TNSC

GAMS AL

MO

AR

LATX

FL

OHINIL

IDOR

WA

NE

MT

WY

UT

AZ

CA

NM

CO

IA

MN

ND

SD

NE

KS

OK

MIWI

ABSK

Cool (Northern) Climate

Warm (Southern) Climate

BC

Inlet water45°F - 55°F

Inlet water55°F - 70°F

These recommendations are for units installed with 240 V service.Increase one model size if unit will be installed with 208 V service.

Call Stiebel Eltron at 800.582.8423 if you have any sizing questions, or if you have high flow showers, or another out-of-the-ordinary situation. Stiebel Eltron service representatives can make recommendations on sizing, or provide assistance with our water heaters, to both homeowners and professional installers.

1.0 -2.0

DHC Tankless Electric Water Heater Sizing GuideD H C M O D E L

Std.Std.HighHighNon-

DHC 3-1 DHC 3-2 DHC 4-2

LAV

ATO

RY

SIN

K 0.50.51.01.02.0

Flow GPM DHC 4-3

code 2.0

LowLowStd.

1.01.02.0

Std. 2.0

1.0 -2.0

KIT

CHEN

SIN

K

Utility /Janitor’sSink

DHC 6-2 DHC 8-2 DHC 9-3 DHC 10-2DHC 5-2

HI

AK

MBON QC

PE

NS

NHVT

MA

CTRI

NJDE

MD

NB

ME

NY

PA

WV VA

NCKY

TNSC

GAMS AL

MO

AR

LATX

FL

OHINIL

IDOR

WA

NE

MT

WY

UT

AZ

CA

NM

CO

IA

MN

ND

SD

NE

KS

OK

MIWI

ABSK

Cool (Northern) Climate

Warm (Southern) Climate

BC

Inlet water45°F - 55°F

Inlet water55°F - 70°F

These recommendations are for units installed with 240 V service.Increase one model size if unit will be installed with 208 V service.

Call Stiebel Eltron at 800.582.8423 if you have any sizing questions, or if you have high flow showers, or another out-of-the-ordinary situation. Stiebel Eltron service representatives can make recommendations on sizing, or provide assistance with our water heaters, to both homeowners and professional installers.

Page 2: DHC Sizing Guide and Technical DataModel 1 DHC 3-1 DHC 3-2 DHC 4-2 DHC 4-3 DHC 5-2 DHC 6-2 DHC 8-2 DHC 9-3 DHC 10-2 Item no. 074050 074052 074053 074051 074054 231546 074424 232204

Simply the Best

DHC Sizing Guide and Technical Data

Simply the Best 17 West St., W. Hatfield, MA 01088 | 800.582.8423 | 413.247.3380 | fax 413.247.3369 | [email protected] | www.stiebel-eltron-usa.com

Model 1 DHC 3-1 DHC 3-2 DHC 4-2 DHC 4-3 DHC 5-2 DHC 6-2 DHC 8-2 DHC 9-3 DHC 10-2

Item no. 074050 074052 074053 074051 074054 231546 074424 232204 074056

Phase - 60/50 Hz 1

Voltage 120 V 208 V 240 V 208 V 240 V 277 V 208 V 240 V 208 V 240 V 208 V 240 V 277 V 208 V 240 V

Wattage 3.0 kW 2.5 kW 3.3 kW 2.9 kW 3.8 kW 4.5 kW 3.6 kW 4.8 kW 4.5 kW 6.0 kW 5.4 kW 7.2 kW 9.6 kW 7.2 kW 9.6 kW

Amperage 25 A 12 A 14 A 14 A 16 A 17 A 18 A 20 A 22 A 25 A 26 A 30 A 32.5 A 35 A 40 A

Min. required circuit breaker size 2

30 A 15 A 20 A 20 A 20 A 20 A 30 A 30 A 30 A 30 A 40 A 40 A 40 A 40 A 50 A

Recommended wire size 3 10 AWG 14 AWG 12 AWG 12 AWG 12 AWG 12 AWG 10 AWG 10 AWG 10 AWG 10 AWG 8 AWG 8 AWG 8 AWG 8 AWG 8 AWG

Minimum water flow to activate unit

0.32 GPM1.2 l/min

0.32 GPM1.2 l/min

0.42 GPM1.6 l/min

0.42 GPM 1.6 l/min

0.42 GPM 1.6 l/min

0.47 GPM 1.8 l/min

0.69 GPM2.6 l/min

0.79 GPM 3.0 l/min

0.79 GPM 3.0 l/min

Weight 4.6 lb / 2.1 kg 5.3 lb / 2.4 kg 5.3 lb / 2.4 kg 4.6 lb / 2.1 kg 4.6 lb / 2.1 kg 4.6 lb / 2.1 kg 5.3 lb / 2.4 kg 5.3 lb / 2.4 kg 5.3 lb / 2.4 kg

Dimensions (H x W x D) 143/16� / 360 mm x 77/8� / 200 mm x 41/8� / 104 mm

Nominal water volume 0.13 gal / 0.5 l

Working pressure 150 psi / 10 BAR

Tested to pressure 300 psi / 20 BAR

Water connections ½� NPT

Technical Data

Gallons/minute .5 41 F° 82 F° — 90 F° 92 F° 108 F°1 20 F° 41 F° 49 F° 49 F° 65 F° 82 F°

1.5 14 F° 28 F° 33 F° 33 F° 44 F° 55 F°Liter/minute 2 22 C° 43 C° — 52 C° 69 C° 86 C°

3 14 C° 29 C° 34 C° 34 C° 46 C° 57 C°5 9 C° 17 C° 21 C° 21 C° 28 C° 34 C°

DHC Tankless Electric Water Heaters

1 Suitable for supply with cold water only.2 This is our recommendation as the manufacturer. Check local codes for compliance if necessary. Tankless water heaters are considered a non-continuous load.3 Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.

The DHC series is tested and certifi ed by WQA against NSF/ANSI 372 for lead free compliance.

Temperature Rise versus Flow RateMaximum temperature rise above ambient water temperature

TempRise°F

Flow Rate GPM