dew point

2
Z-102 Z 160 150 140 130 120 110 100 90 80 70 60 50 40 32 10 20 30 40 50 60 70 80 90 100 110120130140150160 DEWPOINT TEMPERATURE (°F) AIR TEMPERATURTE (°F) 2 5 10 20 30 90 50 40 100 80 60 70 % HUMIDITY 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 DEWPOINT TEMPERATURE (°C) AIR TEMPERATURE (°C) 2 5 10 20 30 40 50 60 70 80 90 100 % HUMIDITY To determine the dewpoint temperature: After measuring the air temperature and relative humidity, use the graph by drawing a horizontal line from the air temperature (Y-axis) to the appropriate relative humidity line. Then draw a vertical line from that intersection down to the dewpoint temperature (X-axis). Dew Point ® Charts based on: t d - t a 17.5 ––––––––– (t d + 240.97) H =100« where H = relative humidity (%) t d = dewpoint temperature (°C) t a = air temperature (°C)

Upload: avi-miled-manosalva-rincon

Post on 07-Sep-2015

217 views

Category:

Documents


4 download

DESCRIPTION

Punto de rocio

TRANSCRIPT

  • Z-102

    Z

    160

    150

    140

    130

    120

    110

    100

    90

    80

    70

    60

    50

    40

    32

    10 20 30 40 50 60 70 80 90 100 110120130140150160

    DEWPOINT TEMPERATURE (F)

    AIR

    TEM

    PER

    ATUR

    TE (

    F)

    2 5 10 2030 9050

    40 100806070

    % HUMIDITY

    70

    65

    60

    55

    50

    45

    40

    35

    30

    25

    20

    15

    10

    5

    0

    -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70DEWPOINT TEMPERATURE (C)

    AIR

    TEM

    PER

    ATUR

    E (C

    )

    25

    1020

    30 40 50 6070

    8090

    100

    % HUMIDITY

    To determine the dewpointtemperature: After measuring the airtemperature and relative humidity, usethe graph by drawing a horizontal linefrom the air temperature (Y-axis) to theappropriate relative humidity line. Thendraw a vertical line from thatintersection down to the dewpointtemperature (X-axis).

    Dew Point

    Charts based on:

    td - ta17.5 (td + 240.97)H =100

    where H = relative humidity (%)td = dewpoint temperature (C)ta = air temperature (C)

  • One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | [email protected] www.omega.com

    More than 100,000 Products Available!

    CANADAwww.omega.caLaval(Quebec)

    1-800-TC-OMEGA

    UNITED KINGDOMwww. omega.co.uk

    Manchester, England0800-488-488

    GERMANYwww.omega.de

    Deckenpfronn, Germany0800-8266342

    FRANCEwww.omega.fr

    Guyancourt, France088-466-342

    BENELUXwww.omega.nl

    Amstelveen, NL0800-099-33-44

    UNITED STATESwww.omega.com

    1-800-TC-OMEGAStamford, CT.

    CZECH REPUBLICwww.omegaeng.cz

    Karvin, Czech Republic596-311-899

    TemperatureCalibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire

    Pressure, Strain and ForceDisplacement Transducers, Dynamic MeasurementForce Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves

    pH and ConductivityConductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation

    HeatersBand Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters

    Flow and LevelAir Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters,Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters

    Data AcquisitionAuto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data LoggersPlug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers

    click here to go to the omega.com home page

    WebMasterText BoxEPG05