What you wantis what you get.independence.innovation.iFillTM.
Don’t wait while lifeis passing you byOxygen patients like you can now enjoy greaterindependence to leave home on the spur of themoment thanks to the innovative iFill PersonalOxygen Station from DeVilbiss.You’ll never bedependent on home cylinder delivery schedules orfear running out of oxygen again – two big reasonswhy you may have been reluctant to leave home.
You decidewhen to filland when to goiFill makes it easy and convenient for you to fillportable oxygen cylinders right in your home to giveyou greater freedom to come and go on your terms.
• iFill gives you the flexibility to fill a wide rangeof cylinders from the M4 and M6, popular fortraveling, to back-up E cylinders.
• Select a cylinder size that best suits yourout-of-home experience. For example, lightweightM6 cylinders provide up to 4 hours of portableoxygen, giving you the option to leave homewithout an oxygen cart. An M6 cylinder, andothers, can be comfortably carried by shoulderstrap or around the waist.
• All cylinders can be refilled as often as you need.
932183 Rev. B
Specifications (continued)Oxygen DurationNOTE-All ambulatory ranges are calculated assuminga breath rate of 20 BPM in PulseDose mode.
UseTimes (Shown In Hours)Flow Rate: 1 1.5 2 2.5 3 4 5 6M4PulseDose 5.7 3.8 2.9 2.3 1.9 1.4 1.1 .9Continuous Flow 1.9 1.3 .9 .7 .6 .5 .4 .3M6PulseDose 8.3 5.5 4.1 3.3 2.8 2.1 1.7 1.4Continuous Flow 2.7 1.8 1.4 1.1 .9 .7 .6 .4ML6PulseDose 8.6 5.7 4.3 3.4 2.9 2.1 1.7 1.4Continuous Flow 2.8 1.9 1.4 1.1 .9 .7 .6 .5CPulseDose 12.1 8.1 6.1 4.9 4.0 3.0 2.4 2.0Continuous Flow 4.0 2.7 2.0 1.6 1.3 1.0 .8 .7DPulseDose 21.0 14.0 10.5 8.4 7.0 5.2 4.2 3.5Continuous Flow 6.9 4.6 3.5 2.8 2.3 1.7 1.4 1.2EPulseDose 34.4 23.0 17.2 13.8 11.5 8.6 6.9 5.8Continuous Flow 11.4 7.6 5.7 4.6 3.8 2.8 2.3 1.9
This chart is intended to be used only as a guide.
DeVilbiss Healthcare100 DeVilbiss Drive
Somerset, PA 15501 USA800.338.1988814.443.4881
www.DeVilbissHealthcare.com
932183 RevB_ConsumerBroch.qxp:14-106-11800brochure1 12/16/08 5:47 PM Page 1
![Page 2: DeVilbiss-iFill-Brochure1](https://reader031.vdocuments.mx/reader031/viewer/2022020519/577cc64d1a28aba7119dfa8f/html5/thumbnails/2.jpg)
iFill puts you in controlThe DeVilbiss iFill Personal Oxygen Stationrepresents the latest in portable oxygenconvenience, providing unmatched flexibilityand ease of use.The iFill unit extracts purifiedoxygen from room air using standard oxygenconcentrator technology.*
• Existing oxygen patient? Don’t worry—iFill can be used with any manufacturer’sconcentrator…even yours.
• Connectors on the cylinder and iFill unit simplyclick into place. Control panel lights indicate whenthe cylinder is filling and when the cylinder is full.
• An M6 iFill cylinder can be filled in just a littleover an hour — not the two hours it can takewith other in-home oxygen filling units. Shorterfill times save energy costs.
* The unit is designed to fill oxygen cylinders only and cannot be used for direct
oxygen inspiration.
Get out and liveResearch findings confirm thatactive patients on ContinuousOxygen Therapy (COT) havea significantly higher survivalrate than inactive patients onNocturnal Oxygen Therapy (NOT).
Source: Petty TL, Bliss PL,AmbulatoryOxygen Therapy, Exercise, and Survivalwith Advanced Chronic ObstructivePulmonary Disease (The NocturnalOxygen Therapy Trial Revisited)Respiratory Care 2000:Vol 45(2) :208.
• iFill can be placed and usedvirtually anywhere in thehome—minimizing the noiseand disruption to daily life.
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00
Surv
ivor
Frac
tion
Years in Study
NOTT Study(Nocturnal Oxygen Therapy Trial)
COT=Continuous Oxygen TherapyNOT=Nocturnal Oxygen Therapy
Low Walk NOT
High Walk NOT
Low Walk COT
High Walk COT
NOTE-All specifications are subject to change without notice.
Choice of cylinders• DeVilbiss PD1000A PulseDose®Oxygen Conserving Cylinder is widelyrecognized as the gold standard of conservingtechnology, offering true 3.5:1savings.The PD1000A is designedto minimize discomfort associated with oxygen therapy.Patients report decreased drying and irritation of the nose.
• Quickly delivers a 16.5 ml bolus of oxygen (per liter setting)deep into your lungs.The volume of oxygen is consistentregardless of your breathing rate, eliminating the need toadjust settings during exertion.
• Intuitive click-stop prescription control knob lets you easilychoose among eight common prescription settings.
• Rugged, impact-resistant GE LEXAN® case.
• Single lumen cannula
• Two standard AA alkaline or NIMH batteries provideapproximately 50 days of operation (2 lpm prescription setting;20 bpm, 4 hours/day) Continuous flow mode requires no batteries.
• 870 PostValve• Allows you to use most manufacturers’
oxygen conserving devices.
• Standard Regulator• Pneumatic continuous flow regulator
• Provides . 5 – 6 lpm continuous flow
• Single lumen cannula
• Brass fittings
LEXAN is a registered trademark of General Electric Company.
DeVilbiss iFill PersonalOxygen Station
M4 60 minutesM6 75 minutesML6 90 minutesC 130 minutesD 215 minutesE 350 minutes
Cylinder Fill TimesNOTE-All filling times are approximate and may varydepending on environmental conditions, such as altitude.Typical cylinder fill time to 2,000 ± 100 psig are as follows:
M4 3.5 lbs.M6 4.1 lbs.ML6 4.8 lbs.C 5.6 lbs.D 7.2 lbs.E 9.8 lbs.
PD1000A Series Cylinder Weights
Specifications
Specifications continued on back cover.
Output 93% 02 ± 3%Width 12.25 inchesHeight 28.5 inchesDepth 22.5 inchesWeight 66 lbs.Warranty 3 years or 8000 hours —