DEVELOPMENT APPLICATION
PDPLANPMTD-2020/007990
APPLICANT: Assetsafe
PROPOSAL: Dwelling
LOCATION: 2 Boultbee Place, ROKEBY
RELEVANT PLANNING SCHEME: Clarence Interim Planning Scheme 2015
ADVERTISING EXPIRY DATE: 08 April 2020
In addition to the Application Form(s), Certificate of Title(s) and any associated
consent documents the following information is available on request:
• Nil
The relevant plans and documents can be inspected at the Council offices, 38 Bligh
Street, Rosny Park, during normal office hours until 08 April 2020.
Any person may make representations about the application to the General
Manager, by writing to PO Box 96, Rosny Park, 7018 or by electronic mail to
[email protected]. Representations must be received by Council on or before
08 April 2020.
To enable Council to contact you if necessary, would you please also include a day
time contact number in any correspondence you may forward.
Any personal information submitted is covered by Council’s privacy policy, available
at www.ccc.tas.gov.au or at the Council offices.
Client:
Project:
Title:
Scale:
COVER SHEET
N.T.S
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
A00
ENGINEERING DRAWINGS
PROPOSED RESIDENCE
For
HiVis BUILDING SERVICES
LOT 466 (No 2) BOULTBEE PLACE, ROKEBY
CONTENTS
PAGE DRAWING SCALE
A00 COVER PAGE N.T.S
A01 EXISTING SITE SURVEY PLAN 1:200
A02 SITE PLAN 1:200
A03 GROUND FLOOR PLAN 1:100
A04 FIRST FLOOR PLAN 1:100
A05 ROOF PLAN 1:100
A06 ELEVATIONS 1:100
A07 BUILDING SECTION A-A 1:50
A08 DOORS & WINDOWS SCHEDULE 1:100
A09 ELECTRICAL LIGHTING PLAN 1:100
A10 WET AREA DETAILS SHEET 1/2 N.T.S
A11 WET AREA DETAILS SHEET 2/2 N.T.S
A12 GENERAL SPECIFICATIONS N.T.S
H01 DRAINAGE PLAN 1:200
H02 SWMP PLAN 1:200
H03 SWMP DETAILS N.T.S
SITE ASSESSMENT:
Property ID No:
3593091
Title Reference: C.T. 175194-446
Land Area: 601 m
2
Proposed G/Floor Area: 83.00 m
2
Proposed F/Floor Area: 43.50 m
2
Proposed Garage Area: 21.77 m
2
Proposed outdoor Area: 30.00 m
2
Building Footprint: 141.60 m
2
Building External Area: 111.45 m²
Site Coverage: 18.54 %
Corrosion Environment Moderate
Alpine Area: N/A
Flood Hazard: None
Bushfire Hazard Level: Low
Unstable Land: None
Threaten Species: None
Cultural Heritage: None
Wind Classification: N2 (40 m/s) to AS4055
Soil Classification: Class M to AS2870
Climate Zone: 26
Energy Rating: TBC
1:100 DIAGRAMS SHADDOW SD1 SUN
Received 16.03.2020
24°56'20" 40.73
1
3
3
°
5
6
'
1
5
.
8
6
1
2
9
°
2
5
'
1
5
.
4
9
24°56'20" 39.44
C.T.175194-446
601m²
BM Nail in stormwater
manhole
R.L. 36.14 A.H.D.
Side entry pit
Comm. pit
3
8
3
7
3
7
3
6
.
2
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
B
O
U
L
T
B
E
E
P
L
A
C
E
CONC. CROSSING
EXISTING SURVEY PLAN
(James McEldowney Surveying)
SCALE 1:200
PHONE CONNECTION
SITE LEGEND:
WATER CONNECTION
SEWER CONNECTION I.V-35.66
SW CONNECTION I.V-35.43
Client:
Project:
Title:
Scale:
EXISTING SITE SURVEY PLAN
1:200
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
A01
Received 16.03.2020
24°56'20" 40.73
1
3
3
°
5
6
'
1
5
.
8
6
1
2
9
°
2
5
'
1
5
.
4
9
24°56'20" 39.44
C.T.175194-446
601m²
BM Nail in stormwater
manhole
R.L. 36.14 A.H.D.
Side entry pit
Comm. pit
3
8
3
7
3
7
3
6
.
2
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
B
O
U
L
T
B
E
E
P
L
A
C
E
PRINCIPLE PRIVATE
OPEN SPACE 24m²
MAX 1:10 GRADE
PHONE CONNECTION
SITE LEGEND:
WATER CONNECTION
SEWER CONNECTION I.V-35.66
SW CONNECTION I.V-35.43
AREA SCHEDULE:
SITE AREA : 601m²
BUILDING EXT. AREA : 116.21m²
SITE COVERAGE : 19.33%
GROUND FLOOR AREA : 83.00 m²
FIRST FLOOR AREA : 43.50 m²
GARAGE FLOOR AREA : 21.77 m²
POS AREA : 24m²
DRIVEWAY AREA : 45.50 m²
BUILDING FOOTPRINT : 139.00 m² (Including outdoor concrete area)
IMPERVIOUS AREA : 416.50 m² (69.30 %)
SITE PLAN
SCALE 1:200
1990
2500
18227
CONC. CROSSING
P R O P O S E D
R E S I D E N C E
FFL 37.40
P R O P O S E D
G A R A G E
FFL 37.40
CUT
1500
8
5
0
0
7
4
5
2
7
6
8
8
9
0
2
5
C
U
T
FILL
FILL
40°
B
O
U
N
D
A
R
Y
E
A
S
T
F
A
C
I
N
G
5
0
°
B85 Vehicle (8m min radius) (2004)
CONC. DRIVEWAY
CONC. DRIVEWAY
VEHICLE MANEUVERING PATH
SCALE 1:200
C
A
R
P
A
R
K
I
N
G
Client:
Project:
Title:
Scale:
SITE PLAN
1:200
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
A02
Received 16.03.2020
UP
GARAGE
DINING
Conc.
CH 2400
GD
3-2127
GD
1-2121
OUTDOOR
LIVING
Td.
OUTDOOR
LIVING
Conc.
CLOTH LINE
Conc.
CH 2400
CH 2400
CH 2400
KITCHEN
ENTRY
CSD820
CSD
820
LOUNGE
CH 2700
CH 2700
CH 2700
LDRY
STACK LINEN
LINEN
BATH
Cft.
ENS
Cft.
BED 3
BED 2
SD
820
SD820
SD770
LIN
E O
F FLO
OR O
VER
GD2-21092
GD4-
21082
14
13
12
11
10
09
0807060504030201
15
16
5900 90 3700 90 1790
250 5900 250 5420 250
900
90
1000
90
1620
2800 250 700
3690
90
4000
250
2870
250
3690
250
4090
2870
250
6400 5670
4190
4090
3120
200
250 1050 250 1930 250 4500 90 3500 250
1300 2180
12070
85903480
12070
510
700
11600
3680
3680
3640
510
3180
90
2020
90
1890
90
3140
250
250
900
90
900
820
600
11000
11510
GW
2-AW
0909
GW1-
AW1804
GW1-
AW1804
GD
1-2121
SD820
GW6-AW2012
LOF
Cft.
fw
fw
fw
LOF
LOF
LOF
GW5-FW0610
Td.
DP.
LOF
Cft.
Conc.
Laminated overlay flooring.
Ceramic floor tiles.
Concrete floor finish
Timber decking: 136 x 25 Spotted Gum
Downpipe
Internal Walls: 90mm stud walls with
10mm plasterboard lining throughout.
(Wet area plasterboard to Bathroom,
Ensuite and Laundry walls)
New levels
LEGEND & NOTES
Rendered EASY LAP Wall Cladding
(3600H x 1200W x 8.5mm)
90mm stud frame internal
10mm plasterboard lining throughout.
(Wet area plasterboard to Bathroom,
Ensuite and Laundry walls)
RH.Rainwater Head
GROUND FLOOR PLAN
SCALE 1:100
3.0m WIDE ELECTRIC
AWNING ROOF OVER
250mm BRICK VENEER WALLS
90mm stud frame internal
10mm plasterboard lining throughout.
(Wet area plasterboard to Bathroom,
Ensuite and Laundry walls)
fwFloor waste
Cj.
Control Joint
28101000
GW
2-
AW
0909
GW
3-
AW
0606
700
GW
4-
AW
1812
Wall Line
N
o
r
t
h
F
a
c
i
n
g
GW
1 &
G
W6
Window
Facing
WINDOW POSITION
(10.4.4 - A1)
3
0
°
6
5
°
Client:
Project:
Title:
Scale:
GROUND FLOOR PLAN
1:100
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
A03
Received 16.03.2020
MASTER
BEDROOM
WIR
LOUNGE
ENSUITE
Cft.
FW
4-FW
2130
FW
1-FW
0630
FW2-FW2012
FW1-FW0630
CH 2400
CH 2400
CH 2400
SD820
CSD
820
CSD
820
FW3-FW0909 FW2-FW2012
3° Roof Fall
DN
14
13
12
11
10
09
0807060504030201
15
16
3° Roof Fall
120
3700 90 1700 90 1400 90 3790
120
6980 90 2110
90
900
90
600
11100
10860
6400 5670
12070
4000
120
120
4240
2975
90
935
4090
3960
3110
250
11510
900
90
1660
1350
4000
120
120
510
3680
3680
3640
11510
870 11200
LOF
LOF
LOF
FIRST FLOOR PLAN
SCALE 1:100
300W Box Gutter
300W Box Gutter
300W Box Gutter
12070
120 120
COLORBOND CAPPING
THROUGHOUT TO PARAPET WALL
fw
Td.
DP.
LOF
Cft.
Conc.
Laminated overlay flooring.
Ceramic floor tiles.
Concrete floor finish
Timber decking: 136 x 25 Spotted Gum
Downpipe
Internal Walls: 90mm stud walls with
10mm plasterboard lining throughout.
(Wet area plasterboard to Bathroom,
Ensuite and Laundry walls)
New levels
LEGEND & NOTES
Rendered EASY LAP Wall Cladding
(3600H x 1200W x 8.5mm)
90mm stud frame internal
10mm plasterboard lining throughout.
(Wet area plasterboard to Bathroom,
Ensuite and Laundry walls)
RH.Rainwater Head
250mm BRICK VENEER WALLS
90mm stud frame internal
10mm plasterboard lining throughout.
(Wet area plasterboard to Bathroom,
Ensuite and Laundry walls)
fwFloor waste
Cj.
Control Joint
RH
RH
RH
RH
RH
RAINWATER HEAD
WITH OVERFLOW OUTLET
+ 100x50 DOWNPIPE WITH
SPREADER FOR
ROOF DISCHARGE
ONTO TO LOWER ROOF
(TYPICAL)
Wall Line
N
o
r
t
h
F
a
c
i
n
g
FW1 Window Facing
3
0
°
1.0M HIGH STUD WALL
AS BALUSTRADE
AROUND STAIR
2
5
°
WINDOW POSITION
(10.4.4 - A1)
Client:
Project:
Title:
Scale:
FIRST FLOOR PLAN
1:100
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
A04
GUTTERING AND DOWN PIPES:
All guttering and down pipes shall be designed and
installed in accordance with AS/NZS 3500.3.2- storm
water drainage, AS 2179 Metal rainwater Goods, the BCA
and the relevant manufacturers instructions. All gutters
must be installed with a fall of not less than 1:500 for
eaves, gutters and 1:200 for boxed gutters. Eave gutters
must be supported by brackets @ max 1200mm crts
METAL ROOFING AND FLASHING:
Colourbond corrugated metal roof sheetingto be
installed to AS 1562 & part 3.5.1 of the NCC and
manufacturers specifications with fixings every 2nd rib
end spans and every 3rd rib elsewhere
Received 16.03.2020
SELECTED COLORBOND
ROOF CLADDING.
ROOF PITCH: 3° FALL THROUGHOUT
OVERALL ROOF AREA: 116.15m²
ROOF PLAN
SCALE 1:100
FABRICATED ROOF TRUSSES:
1. ALL ROOF FRAMING SHALL BE FABRICATED ROOF
TRUSSES AT 900MM C/C.
2. TRUSS FABRICATOR SHALL PROVIDE FORM 55 FOR
ALL TIMBER TRUSS WORK.
3. ALL ROOF FRAMING SHALL BE IN ACCORDANCE
WITH AS1684.2.
4. ALL TRUSS TIE-DOWNS SHALL BE 30X0.8 GI LOOPED
STRAP WITH 4/2.8 FH GALV NAILS.
TIMBER FRAMING NOTES:
1. ALL TIMBER LINTELS SHALL BE HYSPAN OR F17.
2. ALL STEEL LINTELS SHALL BE GALVANISED WITH A
MINIMUM OF 150MM BEARING.
3. WEEP HOLES SHALL BE PROVIDED ABOVE ALL
EXTERNAL BRICKWORK OVER LINTELS.
4. ALL DAMP PROOFING OVER WINDOWS SHALL BE
PROVIDED IN ACCORDANCE WITH BCA AND AS3700.
3° Roof Fall 3° Roof Fall
300W
Box G
utter
300W
Box G
utter
3° Roof Fall
3° Roof Fall
120
120
11100
10860
6400 5670
12070
4000
120
120
4240
4090
3960
3110
250
11510
120
120
510
3680
3680
3640
11510
870 11200
300W Box Gutter
300W Box Gutter
300W Box Gutter
12070
COLORBOND CAPPING
THROUGHOUT TO PARAPET WALL
4000
RH
RH
RH
RHRH
RAINWATER HEAD
WITH OVERFLOW OUTLET
+ 100x50 DOWNPIPE WITH
SPREADER FOR
ROOF DISCHARGE
ONTO TO LOWER ROOF
(TYPICAL)
300W x 150D BOX GUTTER
WITH OVERFLOW.
19mm PLYWOOD BOARD ON
70 x VARIABLE Ht. MGP10 FRAMING
TO ACHIEVE FALL TO DOWNPIPE
OR PROPRIETARY GUTTER STRAPS
ALLOWANCE TO BE MADE FOR
TRUSS BOTTOM CHORD TO
SUPPORT BOX GUTTER
TYPICAL RAINWATER HEAD
SECTION DETAIL
SCALE 1:20
RAINWATER HEAD
WITH OVERFLOW
3° FALL
OVERFLOW OUTLET
DOWNPIPE
GUTTER OUTLET
BRICKWORK
WHERE
APPLICABLE
PARAPET WALL
Client:
Project:
Title:
Scale:
ROOF PLAN
1:100
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
A05
Received 16.03.2020
LEGEND:
RENDERED EASY LAP WALL CLADDING
(3600H x 1200W x 8.5mm)
SELECTED BRICK CLADDING
NORTH-EAST ELEVATION
SCALE 1:100
O/A
B
UILD
IN
G H
T. 6000
2400
2700
300
2400
600
FFL 37.40
CL 39.80
CL 40.10
FFL 40.40
CL 42.80
RL 43.40
SOUTH-WEST ELEVATION
SCALE 1:100
SOUTH-EAST ELEVATION
SCALE 1:100
NORTH-WEST ELEVATION
SCALE 1:100
18
00
FFL 37.40
O/A
B
UILD
IN
G H
T. 6000
2400
2700
2400
600
O/A
B
UILD
IN
G H
T. 6000
2400
2700
2400
600
O/A
B
UILD
IN
G H
T. 6000
2400
2700
2400
600
2400
FFL 37.40
CL 39.80
CL 40.10
FFL 40.40
CL 42.80
RL 43.40
FFL 37.40
BO
UN
DARY
1500
3000
3000
BO
UN
DARY
3000
4
5
°
4
5
°
4
5
°
4
5
°
PD4 BUILDING
ENVELOPE
PD4 BUILDING
ENVELOPE
2500
1500
NGL
NGL
NGL
NGL
1800
FFL 37.40
CL 39.80
CL 40.10
FFL 40.40
CL 42.80
RL 43.40
CL 39.80
CL 40.10
FFL 40.40
CL 42.80
RL 43.40
EXTERNAL CLADDING NOTE:
EXTERNAL LIGHTWEIGHT CLADDING INSTALLATION
AND ARTICULATION JOINTS IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS.
1900
3.0m WIDE ELECTRIC
AWNING ROOF OVER
350Sq BRICK PIER
AROUND STEEL POST
COLORBOND CAPPING
THROUGHOUT TO
PARAPET WALL
COLORBOND CAPPING
THROUGHOUT TO
PARAPET WALL
COLORBOND CAPPING
THROUGHOUT TO
PARAPET WALL
COLORBOND CAPPING
THROUGHOUT TO
PARAPET WALL
COLORBOND CAPPING
THROUGHOUT TO
PARAPET WALL
COLORBOND CAPPING
THROUGHOUT TO
PARAPET WALL
1900
RH
100x50Dp
RH
100x50Dp
RH
RH
RH
RH
RH RH
Client:
Project:
Title:
Scale:
ELEVATIONS
1:100
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
A06
Received 16.03.2020
BUILDING SECTION A-A
SCALE 1:50
The primeter insulation should not block
off air flow coming through the eaves to
the roof ridge capping reduce Insulation
thickness for 600mm from external wall
Bulk insulation directly above ceiling. Minimum
100mm distance from top of uncompressed
insulation to roof sarking at the lowest point
Ventilated Roof Space
590
01
02
03
04
05
06
07
08
10
11
12
13
14
15
16
800 MAX
OVERHANG
STORAGE BELOW
STAIRS
Continuous gap in sarking at ridge
is at least 5mm for all roof pitches.
09
3
7
.
4
0
4
0
.
4
0
FFL 37.40
CL 40.10
FFL 40.40
CL 42.80
RL 43.40
600 MAX
OVERHANG
2700
300
2400
600
100mm THICK CONCRETE PAVING SLAB WITH SL72 TOP MESH 30mm
COVER 25MPa CONCRETE ON PREPARED COMPACTED 100mm FCR BASE.
PROVIDE TOOL JOINT AT 3m x 3m GRID
86
3
7
.
3
1
4
fall
Client:
Project:
Title:
Scale:
BUILDING SECTION A-A
1:50
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
A07
ROOF BATTENS:
75 x 38 F17 HW BATTENS SPACING FOR 0.42
CORRUGATED IRON:
950MM MAX END SPAN- FIXING EVERY SECOND RIB
1200mm INTERNAL SPAN MAX- FIXING EVERY THIRD RIB
TIMBER FRAMING:
90 x 35 mgp10 pine studs 450 crts 90 x 45 mgp10 plates 90 x 19 ribbon plate around
exterior wall double studs at window openings greater than 1500 wide
INTERNAL LININGS WALL:
Wet areas are to be lined with WR Board or villaboard. All other walls to be lined with
10mm plaster-board and installed in accordance with AS/NZS 2589 / 2007
CEILING:
All internal ceilings to be lined with 10mm plaster-board and installed in accordance
with AS / NZS 2589/ 2007
SARKING:
Foil types of vapour permeable roof sarking to be installed as a minimum to all roof
areas and 40mm max sag . Sarking to be layed with a min of 1 5 0mm end lap over
the lower sheet and extend to discharge neatly into roof guttering.
METAL ROOFING AND FLASHING:
Colorbond corrugated metal roof sheeting to be installed to AS 1562 & part 3.5.1 of
the NCC and manufacturers specifications with fixings every 2nd rib end spans and
every 3rd rib elsewhere
INSULATION:
THE FOLLOWING ARE MINIMUM REQUIREMENTS - ROOF R4.1 WALLS R2.5 TIMBER
FLOORS R2.5 FRAMING PART 3.4 NCC all timber framing, fixings and bracing shall
comply with as 1684 and the requirements of BCA part 3.4.3. manufactured sizes
must not be undersized to those specified. for all timber sizes, stress grades, spacings
and wall bracing refer to engineers details. tie-down details shall comply with the
requirements of tables 3.4.3.8 and 3.4.3.9
FIXINGS:
All fixings in treated pine to be galvanized or stainless steel.
VERANDAHS, DECKS AND RAMPS
Any ramps, decks or verandah's greater than 1000mm in height above natural
ground level must have a 1000mm high handrail with suitable balustrade. The
maximum gap between balustrade shall be 125mm. (refer NCC 3.9.2).
STAIR NOTES:
Stairs must be designed and constructed in accordance with the NCC , part 3.9.1.
Each flight of stairs must have no more than 18 and no less than 2 risers each stair
flight.
GUTTERING AND DOWN PIPES:
All guttering and down pipes shall be designed and installed in accordance with
AS/NZS 3500.3.2- storm water drainage, AS 2179 Metal rainwater Goods, the BCA and
the relevant manufacturers instructions. All gutters must be installed with a fall of not
less than 1:500 for eaves, gutters and 1:2 00 for boxed gutters. Eave gutters must be
supported by brackets @ max 1200mm crts
RISERS:
The maximum riser height allowed is 190mm. The vertical measurement of an open
riser must not exceed 125mm. (refer NCC 3.9.1.3)
TREADS:
The Min tread width is 240mm. Treads must have a non-slip resistant finish or a
suitable non-skid strip, grooves near the edge of the nosing's.
LANDINGS:
Where a flight of stairs greater than 3 risers in height (or a max of 570mm in height)
services a doorway a landing must be provided. A landing must be no less than
750mm in length, measured at right angles to the sill of the doorway. Where a
threshold is more than 190mm above the adjoining landing it must incorporate steps
designed in accordance with NCC requirements. A landings gradient must be no
more than 1;50.
BALUSTRADE NOTES:
Balustrade must be designed to take loading forces in accordance with AS 1170.1 or
AS/AZS 1170.1 and be designed and constructed in accordance with all relevant NCC
requirements. Wire balustrade must be constructed in accordance with the NCC Part
3.9.2.3 and its relative tables.
A glass balustrade must comply with AS 1288. A barrier must also be designed to take
loading forces in accordance with AS/NZS 1170.1
ENGINEERED ROOF TRUSSES DESIGNED AND CERTIFIED BY
TRUSS MANUFACTURER- TIE DOWN TO BE CERTIFIED BY TRUSS
MANUFACTURER AFTER DESIGNING TRUSS SYSTEM
CONCENTRATED LOADS:
To support concentrated loads (e.g. girder truss), as a minimum,
a double stud is required in the wall frame.
4.5mm thick Hardiflex eaves
lining fixed to 70 x 35 F5
trimmers. Or Equivalent
approved Paint finish.
CSR Bradford (or equivalent)
poly eave vents @ 1800mm
centres installed as per
manufacturer's
recommendations
WIR JOINERY SHOWN ARE
ILLUSTRATIVE PURPOSE
ONLY. BUILDER TO CONFIRM.
PLASTER CEILING BATTENS:
16 MM NAIL UP BATTENS FIXED TO UNDERSIDE
OF TRUSSES FOR PLASTER INSTALLATION
FOOTING AND FLOOR FRAMING
DESIGN - SEE ENGINEERING DETAILS
REFER ENGINEERING DETAILS
300W x 150D
BOX GUTTER
1000
300W x 150D
BOX GUTTER
250
typ.
176
typ.
Received 16.03.2020
TYPE
GLAZING
U-VALUE
SHGC
FRAME MATERIAL
WIDTH
HEIGHT
No off 2
ID
GROUND FLOOR WINDOW SCHEDULE
GLASS TYPE
GW2
ALUMINIUM
DOOR LIST - EXTERNAL
TYPE
GLAZING
U-VALUE
SHGC
FRAME MATERIAL
WIDTH
HEIGHT
HEAD HEIGHT
ELEVATION
No off
ID
DOOR SCHEDULE
2
DOUBLE GLAZED
1800
ALUMINIUM
400
AWNING/FIXED
GW1
ALUMINIUM
DOUBLE GLAZED
REFER ENERGY EFFICIENCY REPORT
2
FW1
DOUBLE GLAZED
900
900
REFER ENERGY EFFICIENCY REPORT
2
FW2
ALUMINIUM
DOUBLE GLAZED
2000
1200
CLEAR
900
900
ELEVATION
2
GD1
2100
2100
2100
ALUMINIUM
DOUBLE GLAZED
600
3000
1
2100
2100
2700
ROLLER DOOR
ALUMINIUM
1
SWINGING
2100
820
2100
ALUMINIUM
SINGLE GLAZED (FROSTED)
FIRST FLOOR WINDOW SCHEDULE
AWNING AWNING/FIXED
ALUMINIUM
FROSTED
1
FW1
DOUBLE GLAZED
AWNING
ALUMINIUM
1
FW4
DOUBLE GLAZED
CLEAR
2100
3000
AWNING
GD4GD3
SLIDING
CLEARCLEAR FROSTED
GW3
AWNING
1
DOUBLE GLAZED
1800
ALUMINIUM
1200
AWNING/FIXED
GW5
CLEAR
GW4
1
ALUMINIUM
DOUBLE GLAZED
600
600
CLEAR
AWNING
1
DOUBLE GLAZED
600
ALUMINIUM
1000
FIXED
GW6
1
DOUBLE GLAZED
2000
ALUMINIUM
1200
AWNING/FIXED
CLEAR
1
SWINGING
2100
920
2100
TIMBER
NA
GD2
NA
CLEAR
Client:
Project:
Title:
Scale:
DOORS & WINDOWS SCHEDULE
1:100
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
A08
Received 16.03.2020
SD
SD
FIRST FLOOR ELECTRICAL
LIGHTING PLAN
SCALE 1:100
GROUND FLOOR ELECTRICAL
LIGHTING PLAN
SCALE 1:100
LIGHTING PANEL
DOUBLE POWER POINTS
RECESSED LED DOWN LIGHTS (11W) SEALED TYPE
LED UP/DOWN EXTERIOR WALL LIGHT (16W) MOUNTED AT 1800MM AFL.
EXTRACTOR FAN -VENTED TO EXTERIOR-DAMPER
SD
SMOKE ALARM MUST BE INTERLINKED & HARD WIRED
WITH BATTERY BACKUP.
TO AS 3786 AND PART 3.7.2 OF CURRENT BCA.
COMBINATION LIGHT, FAN & HEAT LAMP UNIT (4 LAMP).
4x275W HEAT LAMPS (NOT INCLUDED IN CALCULATION)
1x15W FLUORESCENT GLOBE
Fan
EXTERNAL WEATHER PROOF GPO, 300mm MIN FROM GL
TV OUTLET
ELECTRICAL LEGEND:
NOTE:
INTERNAL ARTIFICIAL LIGHTING TO NOT EXCEED 5W/m²
EXTERNAL ARTIFICIAL LIGHTING TO NOT EXCEED 4W/m²
SURFACE MOUNTED 1 x 28W FLUORESCENT FITTING
Client:
Project:
Title:
Scale:
ELECTRICAL LIGHTING PLAN
1:100
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
A09
Received 16.03.2020
Client:
Project:
Title:
Scale:
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
A10
WET AREA SHEET 1
N.T.S
Received 16.03.2020
TABLE 1
VESSELS OR AREA WHERE
ThE FIXTURE IS INSTALLED
Shower area
Bathrooms
DESIGN AND INSTALLATION CRITERIA FOR WET AREA WATERPROOFING (Table 2.1 AS3740-2004)
DESIGN AND INSTALLATION CRITERIA
Walls
LEVEL OF
RISk
High
Medium
Floor
Waterproofed
and drained.
Concrete and compressed
fibre cement sheet
flooring.
Timber floors including
particleboard plywood
and other materials.
Waterproof
Areas adjacent to baths and
spas (applies to all rooms
in which a bath or spa
is installed).
Medium Concrete and compressed
fibre cement sheet
flooring.
Timber floors including
particleboard, plywood
and other materials.
Walls adjoining other vessels
(e.g. sink, basin or laundry tubs).
Low
Waterproof
N/A
Horizontal surface
waterproof*
Vertical surface
water-resistant.
Horizontal surface
waterproof*
Vertical surface
water-resistant.
Water-resistant
Waterproof
Horizontal surface
waterproof*
Vertical surface
water-resistant.
Laundries and WCs
Bathrooms and laundries
requiring a floor waste in
accordance with Volume one
of the BCA.
Low
High Waterproofed
and drained.
N/A
N/A
Water-resistant†
Waterproof†
N/A
Waterproof where
through the floor,
otherwise, N/A.
N/A Waterproof† N/A
Junctions
Water- resistant
Waterproof
N/A Waterproof†
Penetrations
Waterproof*
N/A
TABLE 2
GENERAL REQUIREMENTS FOR EXTENT OF APPLICATION (Table 4.1 AS3740-2004)
Shower area
Enclosed and hobbed
REQUIREMENTS FOR ELEMENTS
Floors and horizontal
surfaces
Waterproof entire enclosed
shower area, including hob
(see Figure 4.3 (a), AS 3740)
Walls
Waterproof to 150mm min. above
the shower floor finished tiled floor
level or 25mm min. above the
maximum retained water level and
the remainder to be water resistant
to a height of 1800mm min. from
finished floor level.
Enclosed and hobless Waterproof entire enclosed
shower area including
water stop.
Enclosed and stepped
down
Waterproof entire enclosed
shower area including the
stepdown.
Waterproof to 150mm min. above
the shower finished tiled floor level
and the remainder to be water
resistant to a height of 1800mm
min. from finished floor level.
Waterproof to 150mm min. above
the shower finished tiled floor
level or 25mm min. above the
maximum retained water resistant
to a height of 1800mm min. from
finished floor level.
Enclosed and preformed
shower base
N/A Water resistant to a height of
1800mm min. from finished floor
level.
Waterproof internal and external
corners and horizontal joints to
a minimum height of 1800mm
above the floor level with a
minimum width of 40mm either
side of junction.
Unenclosed Waterproof entire shower
area.
Waterproof to 150mm min. above
the shower finished tiled floor level
or 25mm min. above the maximum
retained water level and the re-
mainder to be water resistant to a
height of 1800mm min. from
finished floor level.
Areas outside the shower
area for concrete and
compressed fibre cement
sheet flooring.
Areas outside the shower
area for timber floors
including particleboard,
plywood and other flooring
materials.
Areas adjacent to baths
and spas *† for concrete
and compressed fibre
cement sheet flooring.
Water resistant to entire
floor.
Waterproof entire floor.
N/A
Waterproof internal and external
corners and horizontal joints to
a minimum height of 1800mm
above the floor level with a
minimum width of 40mm either
side of junction.
Waterproof all wall to floor
junctions, where a flashing is
used the horizontal leg shall be
a minimum of 50mm.
N/A Waterproof all wall to floor
junctions, where a flashing is
used the horizontal leg shall be
a minimum of 50mm.
Water resistant to entire
floor.
Water resistant to a height of
150mm min. above vessel and
exposed surfaces below vessel
lip to floor level*
Seal edges for extent of vessel
and junction of bath enclosure
with floor. Where the lip of the
bath is supported by a
horizontal surface this area shall
be waterproof for showers over
bath and water resistant for all
other cases.
Areas adjacent to baths
and spas *† for timber
floors including
particleboard, plywood and
other flooring materials
Waterproof entire floor Water resistant to a height of
150mm min. above vessel and
exposed surfaces below vessel
lip to floor level*
Seal edges for extent of vessel
and junction of bath enclosure
with floor. Where the lip of the
bath is supported by a
horizontal surface this area shall
be waterproof for showers over
bath and water resistant for all
other cases.
Waterproof
penetrations
Wall junctions
and joints
Waterproof internal and external
corners and horizontal joints
within a minimum height of
1800mm above the floor level
width of 40mm either side of
junction.
Penetrations
Waterproof
penetrations
Waterproof
penetrations
N/A
N/A
Waterproof tap and
spout penetrations
where they occur in a
horizontal surface.
Waterproof tap and
spout penetrations
where they occur in a
horizontal surface.
TablE 2 CONTINUED
GENERAL REQUIREMENTS FOR EXTENT OF APPLICATION (TABLE 4.1 AS3740)
VESSELS OR AREA
WHERE THE FIXTURE
IS INSTALLED
Insert baths
REQUIREMENTS FOR ELEMENTS
Floor and horizontal
surfaces
N/A for floor under the bath.
Waterproof entire shelf area,
incorporating a waterstop
under the bath lip and
project a minimum of 5mm
above the tile surface.
Walls adjointing other
vessels (e.g. sink, basin
or laundry tub)
N/A
Walls
N/A for wall under the bath.
Waterproof to 150mm min. above
the lip of the bath*.
Wall junctions
and joints
Penetrations
N/A for wall under the bath*.
Waterproof tap and spout penetrations
where they occur in a
horizontal surface.
Water resistant to a height of
150mm min. above vessel if the
vessel is within 75mm min. of the
wall
Laundries and WCs Water resistant to entire
floor.
Bathrooms and laundries
requiring a floor waste in
accordance with Volume
one of the BCA.
LEGEND:
N/A = Not applicable
* If a shower is included in a bath refer to the requirements for shower
area walls and penetrations.
† Does not apply to joinery fittings such as vanities.
Waterproof and drain entire
floor.
Seal all wall to floor junctions with
a skirting or flashing to 25mm min.
above the finished floor level,
sealed to the floor.
N/A
Where the vessel is fixed to a
wall, seal edges for extent of
vessel.
Waterproof all wall to floor
junctions, where a flashing is
used the horizontal leg shall be
a minimum of 50mm.
Seal all wall to floor junctions
with a skirting or flashing to
25mm min. above the finished
floor level, sealed to the floor.
Waterproof tap and
spout penetrations
where they occur in a
horizontal surface.
N/A
Waterproof penetra-
tions where they occur
through the floor.
VESSELS OR AREA
WHERE THE FIXTURE
IS INSTALLED
Water-resistant†
Water-resistant†
Waterproof
Water-resistant†
Waterproof
Water-resistant†
Water-resistant†
Water-resistant†
Client:
Project:
Title:
Scale:
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
CA11
WET AREA SHEET 2
N.T.S
Received 16.03.2020
SPECIFICATIONS TO THE BCA AND AS STANDARDS
To be read in conjunction with notations on drawings
3.1-SITE PREPARATION
All filling and excavations to be in accordance with Part 3.1.1.1 NCC and table 3.1.1.1
NCC
For slab on ground buildings the finished slab height shall be generally 150mm above
the external finished surface levels in accordance with Part 3.1.2.3 NCC where
applicable
Grade surface levels under timber/suspended floors to obviate ponding
3.2 Footings and Slabs
Excavations for slabs to be in accordance with Part 3.2.2.1 NCC
Filling and compaction under slabs to be in accordance with Part 3.2.2.2 NCC
Site classification and wind speed as per geo-technical report. Drawings certified by
consulting engineer and details to be used in construction.
All stump footings to be in accordance with Part 3.2.5.6 NCC
3.3 Masonry
External walls to be in accordance with Part 3.3.1.0 NCC internal walls to be in
accordance with Part 3.3.1.0 NCC and isolated piers to Part 3.3.1.4. NCC
Vertical articulation joints are to be provided in un reinforced masonry walls for all site
classifications except A & S. Joint width not to be less than 15mm and provided in
accordance with Part 3.3.1.8 NCC( at 6m crts for Straight continuous walls)
Reinforced masonry to be in accordance with Part 3.3.2.2 NCC and associated tables
Wall ties to be provided in accordance with Part 3.3.3.2 NCC
Steel lintels to be provided as required in accordance with Part 3.3.3.4 NCC
Provide open perpends (weepholes) at 1200 ctrs above DPC or Flashing. Flashings to
Part 3.3.4.6 NCC, weather proofing to single skin masonry walls in accordance with Part
3.3.4.7 NCC
3.4 Framing
Sub floor ventilation to Part 3.4.1.2 NCC. At the rate of 6000mm2 per metre of wall
length. Maintain 150mm minimum clearance under timber to ground. This may be
reduced if CCA or equivalent timber is used and passed by the Building Surveyor.
Steel framing in accordance with Part 3.4.2.1 NCC and be protected and earthed in
accordance with part 3.4.2.2 NCC
All timber framing to AS 1684 and stress graded in accordance with Part 3.4.3.2 NCC
Trussed roofs to be certified by manufacturer and a certificate to be provided to the
Building Surveyor.
Tie down and connections to AS 1684, Bracing to be provided as shown on drawings.
Structural steel members in accordance with Part 3.4.4 NCC
3.5 Roof and Wall Cladding
Roof tiling to be in accordance with part 3.5.1.2 NCC to a maximum pitch of 35 degrees
Metal sheet roofing to be in accordance with part 3.5.1.3 and wall cladding to part 3.5.3
3.6 Glazing
All glazing to AS 1288 and AS 2047
All windows, doors and glass panels to the above Aus Standards and written evidence to be provided.
3.7 Fire Safety
Smoke alarms are to be installed and located in accordance with part 3.7.2 NCC
Heating appliances to be installed in accordance with part 3.7.3 NCC and AS 2918 certificate to be provided
for installation
3.7.4 Bushfire Areas
Construction of buildings in bushfire prone areas must comply with AS3959-2009
3.8 Health and Amenity
All wet areas including showers, baths and wall fixtures to be waterproofed to AS 3740 and in accordance with
part 3.8.1.5 to 3.8.1.6
All wall substrates to be MR board or similar. Splash backs to be provided to a height of 1800 above shower
bases, 150 above baths, handbasins and other fixtures including washing machines.
Shower recesses to comply with part 3.8.1.5 to 3.8.1.9 NCC
Room heights to be in accordance with part 3.8.2.2 NCC
Facilities to be provided in accordance with part 3.8.3.1 to 3.8.3.3 NCC
Doors to sanitary compartments to be in accordance with part 3.8.3.3 NCC and clearance of 1200 mm to be
maintained between pan and nearest part of doorway. Where this is insufficient the door is to open out, sliding
or lift off hinges is to be used.
3.9 Safe Movement and Access
Stair construction in accordance with part 3.9.1 NCC with a maximum rise of 190mm and a minimum tread
width of 240mm.
Balustrades to be in accordance with part 3.9.2 NCC. All balustrades to be a minimum height of 1000mm and
have a maximum aperture of 125mm. Loading forces on balustrades to comply with AS 1170.1
Balustrades on stairs to be 865mm above stair nosing and in accordance with part 3.9.2.3
3.12 Energy Efficiency
Meet the requirements of the energy provisions- in particular
Provide added insulation to ceilings dependant on roof colour to a maximum R value 4.1
Provide R2.5 added insulation to walls
Provide R2.5 under timber floors
Provide Building Sealing in accordance with Part 3.12.3 NCC
3.12.5 Services
Services to comply with NCC 3.12.5
Stormwater and Drainage
All stormwater and drainage to be in accordance with AS 3500.
Disability AS 1428.1
All works for Disabled provisions are to be carried out in accordance with AS 1428.1
Client:
Project:
Title:
Scale:
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
CA12
GENERAL SPECIFICATIONS
N.T.S
Received 16.03.2020
DRAINAGE PLAN
SCALE 1:200
F/FLOOR DRAINAGE PLAN
SCALE 1:200
STACK BELOW
+ VENT TO AIR
SS
SH
B
WC
VP
SS
S S S S S
S
S
S
S
S
S
S
S
S
Sk
SS
B
LT
ORG
fw
fw
WC
SH
Bth
B
SH
WC
DP
DP
DP
fw
within 500mm of the connection to central water
LEGEND & NOTES
Thermal insulation for heated water piping must:
a) be protected against the effects of weather and
sunlight; and
b) be able to withstand the temperatures within the
piping; and
c) use thermal insulation in accordance with AS/NZS
4859.1
Heated water piping that is not within a conditioned
space must be thermally insulated as follows:
1. Internal piping
a) All flow and return internal piping that is -
i) within an unventilated wall space
ii) within an internal floor between storeys; or
iii) between ceiling insulation and a ceiling
Must have a minimum R-Value of 0.2 (ie 9mm of closed cell
polymer insulation)
2. Piping located within a ventilated wall space,
an enclosed building subfloor or a roof space
a) All flow and return piping
b) Cold water supply piping and Relief valve piping-
Must have a minimum R-Value of 0.45 (ie 19mm of closed
heating system
cell polymer insulation)
unenclosed building sub-floor or roof space
3. Piping located outside the building or in an
heating system
a) All flow and return piping
b) Cold water supply piping and Relief valve piping-
within 500mm of the connection to central water
Piping within an insulated timber framed wall, such as
Must have a minimum R-Value of 0.6 (ie 25mm of closed
cell polymer insulation)
that passing through a wall stud, is considered to
comply with the above insulation requirements.
Wet areas shown hatched. Refer to
Stormwater line (100mm UPVC)
Sewer line (100mm UPVC)
notes for waterproofing information.
levelled pad prior to commencing footing excavation.
Install inspection openings at major bends for
stormwater and all low points of downpipes.
All plumbing & drainage to be in accordance with local
Council requirements.
Provide surface drain to back of bulk excavation to drain
Plumbing Code of Australia.
Services
The heated water system must be designed and
installed with Part B2 of NCC Volume Three -
SW
S
S
W
S
W
S
W
S
W
S
W
S
W
S
W
S
W
S
W
S
W
S
W
S
W
S
W
SW
VP
VENT TO AIR
S
DN100 STORMWATER LINE TO
LOT CONNECTION POINT
DN100 SEWER LINE TO
LOT CONNECTION POINT
EX. STORMWATER LOT CONNECTION POINT
EX. SEWER LOT CONNECTION POINT
CONC. DRIVEWAY
P R O P O S E D
R E S I D E N C E
FFL 37.40
P R O P O S E D
G A R A G E
FFL 37.40
DN100
D
N
1
0
0
D
N
1
0
0
Ag PIPE
STACK FROM
ABOVE
fw
A
g
P
I
P
E
RH
RH
RH
RH
RH
RAINWATER HEAD
WITH OVERFLOW OUTLET
+ 100x50 DOWNPIPE WITH
SPREADER FOR ROOF DISCHARGE
ONTO TO LOWER ROOF (TYPICAL)
VENT TO AIR
SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW
S
W
S
W
S
W
S
W
S
W
S
W
I.O
GRATED
TREN
CH
300Sq PIT + DN100 OUTLET
100 HIGH KERB
300Sq PIT + DN100 OUTLET
24°56'20" 40.73
1
3
3
°
5
6
'
1
5
.
8
6
1
2
9
°
2
5
'
1
5
.
4
9
24°56'20" 39.44
C.T.175194-446
601m²
BM Nail in stormwater
manhole
R.L. 36.14 A.H.D.
Side entry pit
Comm. pit
3
8
3
7
3
7
3
6
.
2
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
B
O
U
L
T
B
E
E
P
L
A
C
E
Client:
Project:
Title:
Scale:
DRAINAGE PLAN
1:200
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
H01
Received 16.03.2020
24°56'20" 40.73
1
3
3
°
5
6
'
1
5
.
8
6
1
2
9
°
2
5
'
1
5
.
4
9
24°56'20" 39.44
C.T.175194-446
601m²
BM Nail in stormwater
manhole
R.L. 36.14 A.H.D.
Side entry pit
Comm. pit
3
8
3
7
3
7
3
6
.
2
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
B
O
U
L
T
B
E
E
P
L
A
C
E
SOIL MANAGEMENT PLAN
SCALE 1:200
NOTE:
· SEDIMENT AND KERB TURF TO BE CHECKED DAILY
WHILE WORKING ON SITE.
· STORMWATER TO BE CONNECTED AS POSSIBLE TO
STOP EROSION.
P R O P O S E D
R E S I D E N C E
FFL 37.40
P R O P O S E D
G A R A G E
FFL 37.40
KERB TURF
SEDIMENT FENCE
MATERIAL STORAGE AREA
CONC. DRIVEWAY
Client:
Project:
Title:
Scale:
SWMP PLAN
1:200
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
H02
Received 16.03.2020
Client:
Project:
Title:
Scale:
SWMP PLAN
N.T.S
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
H03
IT IS THE DEVELOPOERS/CONTRACTORS
RESPONSIBILITY TO VERIFY THE LOCATION OF ALL
UNDERGROUND SERVICES, INCLUDING BUT NOT LIMITED TO;
GAS, WATER, SEWER, STORM WATER, ELECTRICITY, TELECOMMUNICATIONS
REFERENCED SWMP DRAWINGS
SWMP CONSTRUCTION DETAILS CAN BE OBTAINED FROM
"GUIDELINES FOR SOIL AND WATER MANAGEMENT"
BY THE DEPARTMENT OF PRIMARY
INDUSTRIES WATER AND ENVIRONMENT - JUNE 1999
ENDORSED BY BRIGHTON,
CLARENCE, GLENORCHY, HOBART AND KINGBOROUGH
CITY AND MUNICIPAL COUNCILS.
REVEGITATION & LONG TERM
EROSION CONTROLS:
ONLY REMOVE VEGETATION AS
REQUIRED DURING
CONSTRUCTION.
TREAT HEAVILY CLAYED SOILS
WITH GYPSUM OR LIME AT A RATE
OF 10t/ha TO STABILISE CLAY
PARTICLES.
TEMPORARY STABILISATION CAN
BE GAINED BY SOWING
RYECORN/OATS AT 40kg/ha AND
RYEGRASS CONCORDE AT 10kg/ha
OR SIMILAR FAST ROOTING
GRASSES/CROPS (WITH ADVICE
FROM AGRONOMIST) TO HOLD
TOGETHER TOP SOIL.
PERMANENT GROUND
STABILISATION CAN BE ACHIEVED
USING TURF OR OTHER GRASS
MIXES OF FINE LEAF RYES,
FESCUSES, POA, CLOVERS, ETC.
GARDEN AREAS TO BE MULCHED
WITH WATER EFFICIENT
PLANTINGS THAT HAVE QUICK
ESTABLISHMENT TIMES TO BE
USED IN INITIAL GARDEN BEDS.
WHERE TUNNEL EROSION IS A
EVIDENT THE TUNNELED AREA
MUST BE COMPLETELY BROKEN
UP AND RECONSOLIDATED TO
INTERRUPT CHANNELED FLOWS
OF WATER AND THEN
STABILISED WITH VEGETATION.
DEEP RIP ACROSS THE SLOPE
MAKING SURE THAT THESE RIP
LINES ARE DEEPER THAN THE
BOTTOM OF THE TUNNELS.
COMPACT USING RUBBER
WHEELED TRACTOR ON AREAS
OF SHALLOW TUNNELING.
TUNNELS DEEPER THAN THE
RIPPERS ARE BEST EXCAVATED
AND REPACKED.
SWMP NOTES:
SOLID WASTE MATERIAL TO BE
STORED AND REMOVED FROM
SITE REGULARLY.
REMOVABLE WC TO BE INSTALLED
ON SITE DURING CONSTURCTION
UPTO THE POINT WHERE MAIN
SEWER LINE IS CONNECTED.
STOCK PILES TO BE STABILISED
AS SHOWN ON DETAIL SD9.
VEHICLES/MACHINERY
ACCESSING THE SITE TO USE
HARDENED ACCESS POINT AND
TO BE THOROUGHLY WASHED
(HIGH PRESSURE) TO REMOVE
SOIL AND PLANT MATERIAL
BEFORE LEAVING SITE.
REMOVE ANY SOIL, CONCRETE,
PAINT OR OTHER POTENTIAL
POLLUTANTS FROM ANY AREA
NOT WITHIN THE SITE
BOUNDARY, TO MINIMISE
POLLUTION THROUGH RUN OFF IN
THE RETICULATED STORMWATER
SYSTEM.
RETICULATED WATER MAINS AND
ELECTRICAL CONNECTION
TRENCHED TOGETHER.
NOTES AS
PER SEWER AND STORMWATER
TRENCHING ABOVE.
WATER DIVERSION BARRIER
(DIVERSION OF
UPSLOPE WATER) CONSTRUCTED
FROM SAND OR GRAVEL FILLED
BAGS IN ACCORDANCE WITH
DRAWING SD1.
SILT TRAP/STORM WATER PIT
PROVIDE FILTRATION BARRIER AS
PER DETAIL SD10.
Received 16.03.2020
24°56'20" 40.73
1
3
3
°
5
6
'
1
5
.
8
6
1
2
9
°
2
5
'
1
5
.
4
9
24°56'20" 39.44
C.T.175194-446
601m²
BM Nail in stormwater
manhole
R.L. 36.14 A.H.D.
Side entry pit
Comm. pit
3
8
3
7
3
7
3
6
.
2
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
B
O
U
L
T
B
E
E
P
L
A
C
E
7
:
4
4
A
M
4
:
4
1
P
M
1
2
:
0
0
P
M
2
1
J
u
n
e
N
E
S
W
7
:
4
4
A
M
4
:
4
1
P
M
3
:
0
0
P
M
2
1
J
u
n
e
N
E
S
W
POS SUN % SCHEDULE:
TOTAL AREA : 24m²
AREA RECEIVING SUNLIGHT AT 9am : 0m² = 0%
N
E
S
W
7
:
4
4
A
M
4
:
4
1
P
M
9
:
0
0
A
M
2
1
J
u
n
e
24°56'20" 40.73
1
3
3
°
5
6
'
1
5
.
8
6
1
2
9
°
2
5
'
1
5
.
4
9
24°56'20" 39.44
C.T.175194-446
601m²
BM Nail in stormwater
manhole
R.L. 36.14 A.H.D.
Side entry pit
Comm. pit
3
8
3
7
3
7
3
6
.
2
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
B
O
U
L
T
B
E
E
P
L
A
C
E
24°56'20" 40.73
1
3
3
°
5
6
'
1
5
.
8
6
1
2
9
°
2
5
'
1
5
.
4
9
24°56'20" 39.44
C.T.175194-446
601m²
BM Nail in stormwater
manhole
R.L. 36.14 A.H.D.
Side entry pit
Comm. pit
3
8
3
7
3
7
3
6
.
2
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
S
t
a
k
e
B
O
U
L
T
B
E
E
P
L
A
C
E
POS SUN % SCHEDULE:
TOTAL AREA : 24m²
AREA RECEIVING SUNLIGHT AT 12pm : 16.5m² = 68.75%
POS SUN % SCHEDULE:
TOTAL AREA : 24m²
AREA RECEIVING SUNLIGHT AT 3pm : 21.45m² = 89.37%
Client:
Project:
Title:
Scale:
SUN SHADOW DIAGRAM
1:200
Date Rev. DescriptionBy
Drawn :
Designed :
Checked :
Checked :
Date :
Date :
Rev :Drawing :Job No :
Building Practitioners Board
Tasmania Reg: CC1822J
Mr George Severini
MIE Aust CPEng (Civil/Strucural)
Signature......................................Date.08/02/2020
G. Severini
19129 E
G. Severini
G. Severini
G. Severini
10/10/2019
10/10/2019
ENGINEERS
AUSTRALIA
Reg No: 412110
AssetSAFE
AHS Developments pty Ltd
ABN: 47 111 958 608
GPO Box 1855
Hobart Tas, 7001
M: 0413 272 057
W: assetsafe.com.au
© AHS Developments Pty Ltd
This document is and shall remain the property of AHS Developments. This document may only be used for the purposes for which it was commisioned and in
accordance with the Terms of Engagement for the commission. Unauthorised use of this document in any form whatsoever is prohibited.
19/11/2019A GS
HiVis BUILDING SERVICES P/L
LOT 446 (2) BOULTBEE PLACE, ROKEBY
28.02.2020E DRIVEWAY REVISED FOR BUILDING APPROVAL GS
08/12/2019B DRAWINGS AMENDED FOR MASONRY REQUIREMENTS GS
ISSUED FOR COUNCIL APPROVAL
02/02/2020 C GENERAL AMENDMENTS GS
08/02/2020D GSISSUED FOR BUILDING APPROVAL
SD1