determination of titanium in titanium metal

2
VOLUME 27, NO. 7, JULY 1955 1175 methyl hydroperoxide but not with the dihydroxydimethyl peroxide, and furthermore that the complex with hydroxymethyl hydroperoxide may have a slightly greater absorbancy than that formed with hydrogen peroxide. There are several reasons for this conclusion: The dilution of a test sample for analysis will cause Reaction 1 to reverse. How- ever unless acid is also added, it can readily be shown from Zivailable kinetic data that the rate of this reverse reaction is so slow that,, for example, at the end of 2 hours in neutral solution the amount of free hydrogen peroxide present will have increased only about 10%. The intensity of the color developed initially in the unmodified procedure corresponds to slightly more than the amounts of hydrogen peroxide plus hydroxymethyl hydroperoxide calcu- lated to be present at equilibrium in the concentrated solution before dilution. In the unmodified procedure the color intensity at the end of 5 hours was about 105 to 110% of that expected if all the peroxide present were in the form of the titanium complex with hydrogen peroxide. Presumably practically all of the peroxide present is then in the form of hydrogen peroxide or hydroxymethyl hydro- peroxide and is complexed. In the case of acetaldehyde, the equilibrium data indicate that a far greater portion of the per- oxide will be in the form of hydrogen peroxide or the monohy- droxy hydroperoxide than is the case n-ith formaldehyde. There- fore no significant interference is noted in the unmodified pro- cedure in this case. One must be careful to distinguish between an ordinary organic hydroperoxide, RCH20011, and a hydroxyalkyl hydroperoxide, RCH(0H)OOH. The lat,t,eris a weak addition compound of an aldehyde and hydrogen peroxide which gives color formation with titanium. The former does not apparently complex with titanium to any appreciable extent as discussed previously. The titanium sulfate reagent is reported to hydrolyze to form a precipitate at a pH over 0.8 (3). In the unmodified procedure where the acidity in the colorimeter cell is approximately 0.55, it was observed that over the course of about 4 hours the abso- lute transmittance decreased by 5 to lo%, and a sIight opales- cence appeared. However the rate of development of turbidity was unaffected by the presence of formaldehyde or hydrogen peroxide, so the use of a blank, as was done in all tests reported here, eliminated errors from this source. ACKNOWLEDGRlEhT The authors wish to acknowledge the financial support of the Office of Saval Research, under Contract No. S5ori-OT819, SR-092-008. LITERATURE CITED (1) .Illsopp, C. B., Analyst, 66, 371 (1941). (2) Bendig, AI., and Hirschmuller, H., 2. anal. Chem.. 120, 385 (3) BonBt-llaury, P., Compt. rend., 218, 117 (1944). (4) Egerton, A. C., Everett, A. J., Slinkoff, G. J., Rudrakanchana, (5) Eisenberg, G. ll., ISD. ENG. CHEM., ASIL. ED., 15, 327 (1943). (6) Humpoletz, J. E., Australian J. Sci., 12, 111 (1949). (7) Klenk, Klepzig'a Texti2-Z., 42, 549 (1939). (8) lIacSevin, W. SI., and Urone, P. F., ANAL. CHEM., 25, 1760 (1940). S., and Salooja, K. C.. Anal. Chim. Acta, 10, 422 (1954). (1953). (9) Satterfield. C. S., Wilson. R. E., LeCiair, R. 11.. and Reid, R. C., Ibid., 26, 1792 (1964). RECLIVED for review November 12, 1954. -4ccepted February 1, 1955. Determination of Titanium in Titanium Metal ROLAND A. PAPUCCI F. C. boeman & Co., Cincinnati 70, Ohio The development of new titanium-base alloys, contain- ing iron, chromium, molybdenum, tin, manganese, aluminum, magnesium, nickel, cobalt, copper, silicon, tungsten, and vanadium has led to a search for faster, accurate methods for the direct determination of titanium. The method developed uses the Eberbach Dyna-Cath, high speed magnetic mercury cathode to separate titanium from the most common and interfer- ing elements associated in high-purity titanium metal and titanium alloys. Titanium is then determined colorimetrically as the yellow- pertitanic acid. A significant saving in time has been accomplished with less care necessary to obtain the accuracy comparable to other methods. 0 MEET the need of the expanding titanium industry and T new metallurgical advances, accurate and more rapid methods for the determination of impurities in titanium metal have been developed, especially since 1950. A method has been developed for the direct determination of titanium in high- purity titanium and titanium alloys, which combines speed with :tccuracv and without many painstaking conditions as in existing methods (1, 3, 7, 8). While the theoretical bases for the method are not new, the adaptation of the procedure to titanium and titanium alloys compares favorshly n-ith other existing methods (f. 7. 8, RIethods for the determination of titanium in titanium metal have been reported. Knecht and Hibbert (4) first employed a method using a standard solution of ferric salt for the determina- tion of titanium. It was modified later to include the use of thiocyanate added directly to the test solution instead of an out- side indicator (5, 6). Thompson (8) modified this method adapt- ing it to the determination of titanium in high-purity titanium metal. The method offers satisfactory results and reproduci- bility, hut it possesses certain disadvantages in that an approui- mate titration must be made before the actual determination in most cases, and the removal of impurities is tedious. The method described uses the Eberbach Dyna-Cath (a), high speed magnetic mercury cathode, to separate titanium from chromium, molybdenum, iron, tin, cobalt, nickel, copper, and manganese, the most common and interfering elements associated with titanium. Small amounts of aluminum, silicon, magnesium, oxygen, tungsten, and vanadium do not interfere with the colori- metric determination of titanium as the yellow or orange perti- tank acid. For most allow, the amount of tungsten and vanadium present is usually under 0.04yo and no interference has been observed while working with relatively small samples. * APPAR4TUS AND RE-IGENTS Apparatus. Dyna-Cath, Eberbach Corp., high speed mag- netic mercury cathode. Klett-Sdmmerson photoelectric colorimeter. Beckman quartz spectrophotometer, Model DL-. 1-olumetric flasks, 200-, loo-,

Upload: r-a

Post on 22-Feb-2017

217 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Determination of Titanium in Titanium Metal

V O L U M E 27, NO. 7, J U L Y 1 9 5 5 1175

methyl hydroperoxide but not with the dihydroxydimethyl peroxide, and furthermore that the complex with hydroxymethyl hydroperoxide may have a slightly greater absorbancy than that formed with hydrogen peroxide.

There are several reasons for this conclusion: The dilution of a test sample for analysis will cause Reaction 1 to reverse. How- ever unless acid is also added, it can readily be shown from Zivailable kinetic data that the rate of this reverse reaction is so slow that,, for example, a t the end of 2 hours in neutral solution the amount of free hydrogen peroxide present will have increased only about 10%.

The intensity of the color developed initially in the unmodified procedure corresponds t o slightly more than the amounts of hydrogen peroxide plus hydroxymethyl hydroperoxide calcu- lated to be present a t equilibrium in the concentrated solution before dilution.

In the unmodified procedure the color intensity a t the end of 5 hours was about 105 to 110% of that expected if all the peroxide present were in the form of the titanium complex with hydrogen peroxide. Presumably practically all of the peroxide present is then in the form of hydrogen peroxide or hydroxymethyl hydro- peroxide and is complexed. In the case of acetaldehyde, the equilibrium data indicate that a far greater portion of the per- oxide will be in the form of hydrogen peroxide or the monohy- droxy hydroperoxide than is the case n-ith formaldehyde. There- fore no significant interference is noted in the unmodified pro- cedure in this case.

One must be careful to distinguish between an ordinary organic hydroperoxide, RCH20011, and a hydroxyalkyl hydroperoxide, RCH(0H)OOH. The lat,t,er is a weak addition compound of an aldehyde and hydrogen peroxide which gives color formation

with titanium. The former does not apparently complex with titanium to any appreciable extent as discussed previously.

The titanium sulfate reagent is reported to hydrolyze to form a precipitate a t a pH over 0.8 (3). I n the unmodified procedure where the acidity in the colorimeter cell is approximately 0.55, it was observed that over the course of about 4 hours the abso- lute transmittance decreased by 5 to lo%, and a sIight opales- cence appeared. However the rate of development of turbidity was unaffected by the presence of formaldehyde or hydrogen peroxide, so the use of a blank, as was done in all tests reported here, eliminated errors from this source.

ACKNOWLEDGRlEhT

The authors wish to acknowledge the financial support of the Office of Saval Research, under Contract No. S5ori-OT819, SR-092-008.

LITERATURE CITED

(1) .Illsopp, C. B., Analys t , 66, 371 (1941). (2) Bendig, AI. , and Hirschmuller, H., 2. anal. Chem.. 120, 385

(3) BonBt-llaury, P., Compt. rend., 218, 117 (1944). (4) Egerton, A. C., Everett, A. J., Slinkoff, G. J., Rudrakanchana,

(5 ) Eisenberg, G. ll., ISD. ENG. CHEM., ASIL. ED., 15, 327 (1943). (6) Humpoletz, J. E., Australian J . Sci., 12, 111 (1949). (7) Klenk, Klepzig'a Texti2-Z., 42, 549 (1939). (8) l IacSevin, W. SI., and Urone, P. F., ANAL. CHEM., 25, 1760

(1940).

S., and Salooja, K. C.. Anal. Chim. Acta , 10, 422 (1954).

(1953). (9) Satterfield. C. S., Wilson. R. E., LeCiair, R. 11.. and Reid, R. C.,

Ibid., 26, 1792 (1964).

RECLIVED for review November 12 , 1954. -4ccepted February 1, 1955.

Determination of Titanium in Titanium Metal R O L A N D A. PAPUCCI F. C. boeman & Co., Cincinnati 70, Ohio

The development of new titanium-base alloys, contain- ing iron, chromium, molybdenum, tin, manganese, aluminum, magnesium, nickel, cobalt, copper, silicon, tungsten, and vanadium has led to a search for faster, accurate methods for the direct determination of titanium. The method developed uses the Eberbach Dyna-Cath, high speed magnetic mercury cathode to separate titanium from the most common and interfer- ing elements associated in high-purity titanium metal and titanium alloys. Titanium is then determined colorimetrically as the yellow- pertitanic acid. A significant saving in time has been accomplished with less care necessary to obtain the accuracy comparable to other methods.

0 MEET the need of the expanding titanium industry and T new metallurgical advances, accurate and more rapid methods for the determination of impurities in titanium metal have been developed, especially since 1950. A method has been developed for the direct determination of titanium in high- purity titanium and titanium alloys, which combines speed with :tccuracv and without many painstaking conditions as in existing methods (1, 3, 7 , 8). While the theoretical bases for the method are not new, the adaptation of the procedure to titanium and titanium alloys compares favorshly n-ith other existing methods ( f . 7 . 8,

RIethods for the determination of titanium in titanium metal have been reported. Knecht and Hibbert ( 4 ) first employed a method using a standard solution of ferric salt for the determina- tion of titanium. I t was modified later to include the use of thiocyanate added directly to the test solution instead of an out- side indicator (5 , 6). Thompson (8) modified this method adapt- ing it to the determination of titanium in high-purity titanium metal. The method offers satisfactory results and reproduci- bility, hut it possesses certain disadvantages in that an approui- mate titration must be made before the actual determination in most cases, and the removal of impurities is tedious.

The method described uses the Eberbach Dyna-Cath (a), high speed magnetic mercury cathode, to separate titanium from chromium, molybdenum, iron, tin, cobalt, nickel, copper, and manganese, the most common and interfering elements associated with titanium. Small amounts of aluminum, silicon, magnesium, oxygen, tungsten, and vanadium do not interfere with the colori- metric determination of titanium as the yellow or orange perti- tank acid. For most allow, the amount of tungsten and vanadium present is usually under 0.04yo and no interference has been observed while working with relatively small samples.

*

APPAR4TUS AND RE-IGENTS

Apparatus. Dyna-Cath, Eberbach Corp., high speed mag- netic mercury cathode.

Klett-Sdmmerson photoelectric colorimeter. Beckman quartz spectrophotometer, Model DL-. 1-olumetric flasks, 200-, loo-,

Page 2: Determination of Titanium in Titanium Metal

1176 A N A L Y T I C A L C H E M I S T R Y

and 10-ml. capacity. Erlenmeyer flasks, 500-ml. capacity. Flask tongs. Beakers and covers.

Reagents. Potassium bisulfate, fused, pure. Sulfuric acid (1 to 3), ( 1 to 5), and ( 1 to 9). Hydrogen per-

oxide, c.P., 3%. National Bureau of Standards standard samples, Kos. 154 and

121b. Standard titanium sulfate solution (1 ml. = 0.0001 gram of

titanium). Preparation. Fuse 0.34 gram of titanium dioxide (sample 154)

in a platinum dish with approximately 10 grams of potassium acid sulfate and dissolve the cold melt in 200 ml. of hot sulfuric acid (1 to 9). Cool to room temperature and dilute to 2 liters in a volumetric flask with sulfuric acid (1 to 9).

PROCEDURE FOR DETERMINATION OF TITANIUM

Weigh accurately 0.20 gram of the sample and transfer to a 500- ml. Erlenmeyer flask. Add 100 ml. of sulfuric acid 1 to 5) and

tion requires approximately 15 minutes. Remove from the hot plate and cool. Metallic tungsten is insoluble in the nonoxidizing acid (7 , 9) and minute black particles of metallic tungsten may separate in the solution. Since the amount of tungsten actually present in most titanium alloys is small, it may not be visible to the naked eye. If such a residue is present or suspected, remove by filtration on a KO. 40 Whatman filter paper. Vana- dium (1, 7 , 9), also in minute quantity if present, for the most part accompanie? the tungsten and is removed with it.

heat over a hot plate until completely dissolved. (I. his opera-

50 1 0.5 030 035 040

P€ffC€NTAGGE 7 / T A N / U M

Figure 1. Titanium in titanium-base alloy*

Add 50 ml. of 3% hydrogen peroxide to the filtrate; the solu- tion changes from a greenish blue to a yellol\- orange. Evapo- rate the solution until the yellow color disappears, then to fumes of sulfur trioxide. Do not fume strongly. Cool, add 75 nil. of distilled water, and boil for 5 minutes. Cool, and place the solution, washing well the sides of the flask, in the Dyna-Cath cell beaker, containing approximately 1.5 pounds of clean mer- cury. Cover the cell beaker and electrolyze the electrolyte for approximately 15 minutes a t 10 to 15 amperes, to remove chro- mium, molybdenum, tin, cobalt, nickel, copper, zinc, iron, and most of the manganese from the electrolyte. For total alloy contents of less than lo%, the solution may assume the yellow color of pertitanic acid. Interrupt the electrolysis when this occurs and remove the electrolyte from the cell, washing well the inside of the cell and cathode Fvith small quantities of dis- tilled water. The electrolyte may be clear or yellorvish in color. If the volume of the solution is more than 200 ml., place the contents on the hot plate in a 500-ml. heakrr and evaporate to

approximate volume. Cool, make up to volume in a 200-ml. volumetric flask, and pipet 2 ml. of the homogeneous solution in a 100-ml. volumetric flask. Add 20 ml. of sulfuric acid (1 to 3) and 50 ml. of distilled water. 4dd 5 ml. of 3% hydrogen per- oxide and make up to volume. Compare the color reading against known values of the standard titanium sulfate solution or compare reading, using blue filter No. 42 on the Klett-Summerson, to the calibration curve, Figure 1, determined by using Bureau of Standards standard samples 121b and 154. Percentage reading X 250 = % titanium in sample, when a 0.20-gram sample is taken.

Table I . Determination of Titanium in Titanium Metal

Nominal Compn. of Alloy, %

Fe 0.50, N 0.03, C 0.04, 0 0.50, M n 0.05, W 0.03

Ti-15OA Fe 1.30, Cr 2.50, 0

0.30, C 0.02, N 0.025, W 0.04

Ti-175A Fe 1.75, Cr 3.00, 0 0.50, N & M n 0.04, C 0.03, W 0.02

Fe 2.00, Cr 2.00. h.10 2.00. C 0.04, 0 0.40, N & w 0.02

Titanium Determined, % Thompson’s Klett- method (8) Summerson Beckman

95.89 9 5 , 9 2 95 .86 95 .86 95 .84 95 .86

9 5 . 8 9 95 .96 95 .89 95 .91 95 .89 95.87

9 5 , 9 4 95 .94 95 .90 95 .92 95 .92 95 .89

9 4 , 0 3 94 .01 9 4 . 0 4 94 .02 9 4 , 0 5 9 4 . 0 6 93 .96 9 3 , 9 8 9 4 . 0 2 93 .98 93 .98 94 .02

9 3 . 6 7 93 .76 93 .78 93 .70 93.74 93 .75 9 3 , 6 6 9 3 . 7 2 9 3 . 7 4

Fe 2.00, Cr 2.00, Mo 9 2 . 8 0 92 .80 92 .82 2.00, C 0.04, 0 0.40, 9 2 . 7 6 92.81 9 2 . 8 0 N & W 0.02 92 .72 9 2 , 7 5 92 .80

RC-130B hfn 4.00, A1 4.00, 0

0.30, N 0.05. C 0.06

92.08 92 31 92 .38 92 .12 92.31 92 .31 9 2 . 1 8 9 2 . 3 0 92 .28 9 2 . 1 8 92 .26 92 .28 92 .20 92 .30 92 .30

Ti-15OB 85.80 85.87 85 .90 Cr 5.00, Mo 5.00. Fe 85.84 8 5 , 8 7 85 .92

5.00, 0 0.30, N 0.03, 8 5 . 7 8 8.5,88 85.90 C 0.04

A similar curve for the Beckman spectrophotometer may be determined using the same standards and measuring the per- centage of absorbance or transmittance a t 425 mp on the Beck- man. The results appear in Table I.

DISCUSSION

The results obtained were found to be equally as accurate as those obtained by Thompson. The results obtained on the Beck- man spectrophotometer can be considered more precise than the results obtained on the Klett-Summerson. The time involved in the two methods was in favor of the direct determination with an average time of 80 minutes. Less care is necessary to obtain the same accuracy.

LITERATURE CITED

(1) Am. SOC. Testing Materials, “Methods for Chemical Analysis

(2) Center, E. J., Overbeck, R. C., and Chaxe, D. L., ANAL. CHEM.,

(3) Hillebrand, W. F., and Lundell, G. E. F., “Applied Inorganic

(4) Knecht, E., and Hibbert, E., Ber., 36, 1549 (1903). (5) Knecht, E., and Hibbert, E., “Xew Reduction Methods in

Volumetric Analysis,” pp. 11, 51, Longinans, Green, London, 1918.

of Metals,” ASThl Designation E 30-45 (1945).

23, 1134 (1951).

Analysis,” Wiley, iYew York, 1929.

(6 ) Ib id . , pp. 10, 70, 1925. (7) Scott, TV. W., “Standard hlethods of Chemical Analysis,” 5th

(8) Thompson, J. AI., A N ~ L . CHEM., 24, 1632 (1952). (9) Willard, H. H., and Diehl, H., “Advanced Quantitative

ed., Van Sostrand, New York. 1939.

bnalysis,” 5th ed., Van Nostrand, New York, 1950.

RECEIVED for review July 12, 1954. Accepted January 28, 1955.