detentions in port of koper in the year 2005 - … · detentions in port of koper in the year 2005...

51
DETENTIONS IN PORT OF KOPER IN THE YEAR 2005 1 Date & Place of Detention 2 Vessel Name, Type, IMO No & GT 3 Flag 4 Owners Operator Charterers 5 Classification Society 6 P D 7 Summary 03/01/2005 Koper SERENADE General cargo 7116860 4255 Italy Monteverde Navigazione Napoli Italy RINA Detained for 9 days. 26 recorded deficiencies. Wheelhouse bulkhead corroded through. Both accommodation air vent on monkey bridge corroded through. Accommodation air vent damper sized. On 2 nd officer cabin window frame detached. Several self ignition lights inoperative. Funnel corroded through. Acetylene pipes connection improper. Gasket holder on store door corroded through. Galley door corroded through. Anchor ball improper size. Ropes made fast on warping drums. PS stopper inoperative. Improper gauges on all DO tanks. ON WT4 tank air pipe temporary repaired. On steering gear limit switch missing. In ER STB one frame bent and one frame holed. Several DO pipes leaking. QCV on three tanks inoperative. CO2 room bulkhead corroded through. Front bridge bulkhead corroded through. ER air vent corroded through. Emergency fire pump inoperative. Limit switches on davits inoperative. Galley air vent damper sized. Abandon drill failed. Emergency preparedness failed. 04/01/2005 Koper CATA General cargo Georgia Uni Marine Management International Register of Shipping Detained for 3 days. 23 recorded deficiencies.

Upload: vudien

Post on 21-Jun-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

DETENTIONS IN PORT OF KOPER IN THE YEAR 2005

1

Date & Place of Detention

2

Vessel Name, Type, IMO No & GT

3

Flag

4

Owners Operator

Charterers

5

Classification Society

6 PD

7

Summary

03/01/2005 Koper

SERENADE General cargo 7116860 4255

Italy Monteverde Navigazione Napoli Italy

RINA Detained for 9 days. 26 recorded deficiencies. Wheelhouse bulkhead corroded through. Both accommodation air vent on monkey bridge corroded through. Accommodation air vent damper sized. On 2

nd

officer cabin window frame detached. Several self ignition lights inoperative. Funnel corroded through. Acetylene pipes connection improper. Gasket holder on store door corroded through. Galley door corroded through. Anchor ball improper size. Ropes made fast on warping drums. PS stopper inoperative. Improper gauges on all DO tanks. ON WT4 tank air pipe temporary repaired. On steering gear limit switch missing. In ER STB one frame bent and one frame holed. Several DO pipes leaking. QCV on three tanks inoperative. CO2 room bulkhead corroded through. Front bridge bulkhead corroded through. ER air vent corroded through. Emergency fire pump inoperative. Limit switches on davits inoperative. Galley air vent damper sized. Abandon drill failed. Emergency preparedness failed.

04/01/2005 Koper

CATA

General cargo

Georgia Uni Marine Management

International Register of Shipping

Detained for 3 days. 23 recorded deficiencies.

7214234 2756

Tarous Syria

Rudder back piece cracked. ORB entries not in accordance with instructions. Two wipers in wheelhouse inoperative. Glass in wheelhouse made of plexiglass. Funnel damper inoperative. Wheelhouse bulkhead corroded through and repaired with silicon. Accommodation bulkhead corroded through. Accommodation air vent corroded through. Monkey deck cracked and temporary repaired with canvas. PS lifeboat with some cracks. On lifeboat deck outside emergency lights missing. Front bridge bulkhead corroded through. On hold 2 hatch covers some frames cracked. FCSL air vent corroded through. Anchor washing line temporary repaired. QCV on emergency generator fuel tank inoperative. In hold 1 one deck girder corroded through. Sewage tank repaired with silicon. Oil pipe for stern tube made of rubber. Two QCV on fuel tank inoperative. OWS inoperative. ISM preparedness failed.

07/01/2005 Koper

EUROCARRIER Bulk carrier 7366128 15.627

Cambodia Diamond Marine Enterprises Piraeus Greece

Phoenix Register of Shipping

Detained for 6 days. 41 recorded deficiencies. Wheelhouse bulkhead corroded through. Pilot cabin bulkhead corroded through. Glasses on navigational lights not in accordance with colreg 72. Wire on horn for manual activation torn. Accommodation air vent corroded through. Both funnel dampers do not close completely. Funnel door corroded through. Galley air vent

damper sized. ER air vent corroded through. Skylight corroded through. On air condition room air vent damper sized. On AB cabin bulkhead corroded through. Glass on accommodation door crashed. 3

rd engineer

cabin bulkhead corroded through. Deck generator fuel tank without gauge and with improper fuel pipe connection. Self igniting lights inoperative. Tally room bulkhead corroded through. Electric bondage on cable line disconnected. Three bilge sounding pipes corroded through. Watch room bulkhead corroded through. Store bulkhead corroded through. DB 3C air pipe corroded through. Middle mast house bulkhead corroded through. On hold 2 PS three hatch coaming frames cracked. FP air pipe corroded through. On hold 3 hatchcoaming four frames cracked. QCV on service DO tank leaking. Fuel pipe for caterpillar DG improper. QCV on DO settling tank inoperative. DO5 air pipe corroded through. DO4 air pipe corroded through. Emergency DG not as required. On all fuel tanks spring return valves on sight glasses blocked with wire. On ME cylinder 1 cooling water leaking. ER bilge has to be dried and cleaned. Bilge tank with improper piping arrangements, which require the tank cover to be open. Synchronisation between DG 1 an3 and DG 1 and 2 impossible. Meat room temperature

–10 °C. Abandon ship drill failed. ISM failed.

10/01/2005 Koper

KHALIFEH LIVESTOCK Livestock 7026871 3.356

Honduras Sea Shipping & Chartering Beirut Lebanon

Croatian Register of Shipping

Detained for 3 days. 12 recorded deficiencies. Both wheelhouse wipers inoperative. Funnel damper sized. In FCSL STB two frames damaged. Air vent covers sized. Injector cooling water pipe made of rubber. Compressor cooling water pipe made of rubber. ER STB 3 frames bent. DG cooling water pump not fixed on the base. ER fire alarms inoperative. Life boat engine inoperative. QCV on fuel tank inoperative.

14/01/2005 Koper

REENVI General cargo 7111860 1596

Albania Zotaj Shipping Durres Albania

Albanian Register of Shipping

Detained for XX days. 16 recorded deficiencies. Saloon window glass cracked. Saloon window out of hinges. Main magnetic compass missing. Gyrocompass inoperative. Charts not up to date. Rudder cracked. All ER air vent corroded through. Deck DG piping improper. Steering gear room entrance cover corroded through. Hatch covers on hold 2 corroded through. Hatch covers on hold 1 corroded through. On hold 1 more than 20 frames damaged, detached from hull or girders. On hold 1 several deck beams detached. Wheelhouse deck corroded through.

20/01/2005 Koper

ATHOS

Bulk carrier 7617319 40.670

Panama Golden Port Shipmanagement Athens Greece

Lloyd Register of Shipping

Detained for 3 days. 25 recorded deficiencies. ER air vent STB corroded through. ER air vent STB corroded through. ER air vent PS corroded through. Skylight corroded through. Accommodation bulkhead on captain

deck corroded through. Radio room bulkhead corroded through. ER air vent remote dampers sized. Accommodation bulkhead on bridge deck corroded through. Galley store bulkhead corroded through. Smoke room air vent corroded through. Store room air vent corroded through. Oil spill room bulkhead corroded through. DG air vent corroded through. Lower stern light glass cracked. All navigational lights with improper glasses. Ball protection on FOT 5 air pipe corroded through. Ball protection on DO serv air pipe corroded through. Welding cracked on hatch cover on hold 2. Bulkhead in paint locker not air tight. Antistatic carpet in control room missing. Drain cooler leaking. Lead lamps on all ER fire sensors inoperative. OWS 15 ppm not adjusted. Abandon drill failed. ISM maintenance failed.

24/01/2005 Koper

EUROFEEDER

Ro – ro ship 7946394 8.428

Malta Valiant Shipping Athens Greece

Registro Italiano Navale

Detained for 6 days. 35 recorded deficiencies. Wheelhouse bulkhead corroded through. 2 green side lights glasses cracked. 2 red side lights glasses cracked. Stern navigational light missing. Magnetic compass with air bubbles. ER air fan bulkhead corroded through. ER air vent corroded through. ER fan switch detached. Accommodation door corroded through. DG room bulkhead corroded through. Two DG air vent doors corroded through. Store cover corroded through.

Washing tank air pipe corroded through. Sopep room door corroded through. Cofferdam air pipe corroded through. AP air pipe ball missing. WBT 5 air pipe corroded through. FP air pipe ball protection corroded through. ART air pipe corroded through. FW air pipe corroded through. Galley water pipe not as required. High pressure double skin pipes on ME disconnected. On all 3 DG high pressure double skin lines not properly fitted. Aux engine bilge to be dried and cleaned. Water line for purifiers made of rubber. Hydrophore piping not as required. Boil filling water pipe not as required. AE bilge pipe PS leaking. High pressure pump on DG1 leaking. Return pipe from expansion tank not as required. Antistatic carpet missing. Day FO tank QCV inoperative. STB lifeboat engine inoperative. Abandon drill failed. ISM maintenance failed.

31/01/2005 Koper

MEDITERRANEAN STAR Chemical tanker 7320370 1.533

Panama Soysay Co. Istanbul Turkey

International Register of Shipping

2 Detained for 3 days. 9 recorded deficiencies. Radio officer cabin bulkhead corroded through. Workshop air vent corroded through. CO2 air vent corroded through. FW tank air pipe corroded through. Bell missing. ME cooling pipe made of rubber. AE cooler pipe made of rubber. EM lighting inoperative. AIS inoperative.

02/02/2005 Koper

HILDA General cargo 8230259

Russian Federation

Dedezdha Shipping management

Russian Maritime Register of Shipping

Detained for 4 days. 26 recorded deficiencies. On wheelhouse both wipers inoperative. Three glasses on

2.516 wheelhouse windows cracked. Charts not up to date. ER skylight corroded through. Welding room air vent corroded through. Battery room bulkhead corroded through. Rescue boat engine without fuel. Bridge bulkhead corroded through. On hold 3 hatch coaming cracked. On hold 3 bulkhead frames bent. On hold 1 bulkhead frames bent and detached. DB1 tank air pipe corroded through. DB1 STB air pipe corroded through. On FCSL hawser pipe cracked. In FCSL one frame heavy bent. Both ER air vent corroded through. Sanitary piping temporary repaired. Fresh water pipe made of rubber. EM fire pump insufficient pressure. In both lifeboats pumps inoperative. High pressure pump casing leaking. AE cooling water leaking. On ME double skin connection lines leaking. On ME 2 double skin alarm iniperatiove. Low pressure flanged joint shields missing. Doubler under stern anchor cracked.

07/02/2005 Koper

EUROGALAXY General cargo 8861668 1.719

Georgia European Corporation Athens Greece

International Register of Shipping

Detained for 3 days. 9 recorded deficiencies. ER fire sensors inoperative. Sky light glass cracked. Stern navigational light glass cracked. Accommodation heating poor. Publications missing. EBED expired. Immersion suits lights missing. Filter on galley hood missing. Internal insulations poor.

10/02/2005 Koper

MODISK General cargo

Russian Federation

Adnan Saigun Istanbul

Russian Maritime Register of Shipping

Detained for 2 days. 17 recorded deficiencies. Charts not up to date.

8031392 1680

Turkey Wheelhouse wipers inoperative. Accommodation air vent corroded through. BWT 3 air pipe corroded through. BWT 2 air pipe corroded through. BWT 5 air pipe corroded through. BWT 4 air pipe corroded through. BWT 7 air pipe corroded through. ME cylinder 3 cooling water leaking. ME cylinder no 8 cooling water leaking. Cooling water on cylinder No 2 leaking. QCV on fuel tanks inoperative. Fresh water line in ER temporary repaired. DG3 cooling water leaking. Bilge water pipe made of rubber. On DG 1 cooling water leaking. DG 2 can not be synchronised.

14/02/2005 Koper

MARMARA – M General cargo 7413945 1943

Georgia Uni Marine Management Tarous Syria

International Register of Shipping

Detained for 2 days. 18 recorded deficiencies. Charts not up to date. Gyro repeaters inoperative. Wheelhouse bulkhead corroded through. Galley skylight corroded through. Funnel corroded through. Limit switches on davits inoperative. Emergency lightning on boat deck sized. DO C2 air pipe corroded through. In FCSL 4 frames bent. On hold 1 bottom plate of hatch covers corroded through, one frame detached. FP air pipe corroded through. DT air pipe corroded through. BW T4 fore and aft air pipes corroded through. Jacketed line connection not protected. Rubber pipe connection between settling tank and sludge tank with cover open. ER bilge dirty. ER fire sensors inoperative. Crew not using personal

protective equipment.

23/02/2005 Koper

SORMOVSKIY – 3006

General cargo 8035166 2491

Russia Volga Don Shipping Rostov on Don Russia

Russian Maritime Register of Shipping

Detained for 4 days. 7 recorded deficiencies. Skylight corroded through. Funnel dampers corroded through. Deck on generator room corroded through. ON PS aft hull corroded through in two places. OWS not calibrated on 15 ppm. Low pressure flanged joints shields missing.

24/02/2005 Koper

ASK

Cement carrier 5189136 836

Panama Trajekt d.o.o. Split Croatia

Bureau Veritas

Detained for 2 days. 10 recorded deficiencies. AIS not installed. Wheelhouse bulkhead corroded through. Magnetic compass with big bubbles. AP air pipe ball protection detached. Under cable lifter hawser pipe plate detached. Hawser openings plates missing. Cargo pump room cover corroded through. Cargo compressor no 2 inoperative. Sludge tank gauge pipe not as required. Fuel pipe for DG 2 made of rubber.

25/02/2005 Koper

LINZ General cargo 7023805 4216

St. Vincent & Grenadines

Argo Maritime Varna Bulgaria

Bulgarski Koraben Registar

Detained for 2 days. 26 recorded deficiencies. Gasket holder on hatch covers bad. Bulkhead between hold 1 and fire pump room corroded through. Hold air vent corroded through. Bridge air vent corroded through. Boat swain store window made of Plexiglas. Galley hood dirty. On service tank improper valve. QCV on service tank disconnected. Gauge on service tank improper. ER bilge dirty. ME dirty. Funnel dampers corroded through. Skylight holed. Wheelhouse bulkhead corroded through. Accommodation air vent

corroded through. Accommodation bulkhead corroded through. Bridge PS air vent corroded through. ER door corroded through. DB4 air pipe corroded through. WT3 air pipe corroded through. WT1 air pipes corroded through. Scuttle glass on front bridge missing. Low pressure flange joints missing. Abandon drill failed. FF appliances not as required. ISM failed.

04/03/2005 Koper

KRIS

General cargo 7232652 1510

Comoros Glas Trading Piraeus Greece

International Naval Surveys Bureau

Detained for 4 days. 33 recorded deficiencies Wheelhouse bulkhead corroded through. Accommodation air vent dampers sized. Magnetic compass with air bubbles. Horn inoperative. Two red lights for ship not under command with improper glass. ER skylight corroded through. Fast rescue boat deflated. One stern light missing. On life rafts weak links missing. Steering gear room air vent corroded through. On hold 2 hatch covers frames corroded through. Captain and chief engineers air conditions installed out of class condition. Front bridge bulkhead corroded through. Cargo opening on hatch covers not bolted. Delivery fuel line for emergency fire pump made of rubber. Both hawser pipes cracked. Windlass bad plate corroded through. On FCSL anchor light missing. QCV on fuel tank for emergency fire pump sized. On hold 1 FWD entrance cover corroded through. DB1 STB air pipe corroded through. Captain cabin bulkhead corroded

through. Hydrophore gauges not as required. Bilge pump leaking. On both DGs guards missing. OWS with rubber pipe connections. Alleged illegal discharge pipe installed to open bilge tank. On low pressure line flanged joints shields missing. Deck over hidrophore and hatch covers hydraulic pumps corroded through with water leaking on hydraulic pumps. Insufficient quantity of food on board. Crew do not wear personal protective equipment. STB gangway damaged- unusable. ISM maintenance failed.

10/03/2005 Koper

NEJLA 1 General cargo 7321283 2569

Georgia Harmanda Shipping Istanbul Turkey

International Register of Shipping

Detained for 4 days. 26 recorded deficiencies Charts not up to date. Steering magnetic compass with air bubbles. EPIRB inoperative. On alleyway door glass cracked. Galley air vent corroded through. Delivery fuel pipe for deck generator made of rubber. Self ignition lights inoperative. Galley sky light holed. Stern light casing damaged. ER air vent damper sized. On hold 1 winch brake handle not as required. Gauge on emergency generator fuel tank not as required. In paint room 3 frames bent. On FO 3 DB tank bulkhead corroded through, tank communicate with ballast tank 3 PS. PS hawser pipe temporary repaired. FP air pipe corroded through. FP manhole cover not bolted. Emergency fire pump insufficient pressure. ER fire sensors inoperative. Pipes on bilge pump

temporary repaired. DG 2 inoperative. DG 1 and deck generator can not be synchronised. Cooling water on cylinder 3 leaking. Low pressure flanged joints shields missing on ME and DGs. When filling DB3 ballast tank minor pollution occurred. ISM maintenance failed.

11/03/2005 Koper

EDARTE

General cargo 7397971 1628

Albania Zotaj Shipping Durres Albania

Albanian Register of Shipping

Detained for 5 days. 18 recorded deficiencies Crew without medical examination. Emergency fire pump inoperative. Insulation in steering gear room wetted. ER bilge dirty. Heating inoperative. Nautical publications expired. Fire hoses leaking. Life boat engine inoperative. Lifeboat not properly maintained. Tracking pendants missing. Self igniting lights inoperative. Galley filters missing. Galley dirty. Sanitary facilities dirty. Rubber gaskets in bad condition. Fire boxes in bad condition. ISM maintenance failed.

16/03/2005 Koper

MIDLAND 201

General cargo 8846761 2554

Malta Midland Shipping Toronto Canada

Russian Maritime Register of Shipping

Detained for 2 days. 10 recorded deficiencies Funnels corroded through. Wheelhouse door corroded through. Master cabin bulkhead corroded through. Ch. Eng. Cabin bulkhead corroded through. Mess room bulkhead corroded through. Magnetic compass gimble arrangement sized. Rubber pipe for cleaning installed on DO tank. Grey water pipe made of rubber. Water pipe for hot water partially made of rubber.

23/03/2005 Koper

ADAL

General cargo 8883654

Albania Mema Osman Durres Albania

Albanian Register of Shipping

Detained for 27 days. 47 recorded deficiencies Charts not up to date. Electric power supply to Navtex not available. Electric power supply to

437 AIS not available. Main magnetic compass missing. Steering magnetic compass inoperative. Rudder indicator missing. Radar inoperative. Two red lights for ship not under command missing. All navigational lights with improper glass. Whistle inoperative. On FCSL bell missing. Both MOB expired. Captain cabin window cracked. Mess room scuttle window glass cracked. In officers saloon 2 windows glasses cracked. In FCSL scuttle glass crashed. Accommodation door corroded through. On all doors gaskets missing. On hold 2 air vent damper missing. On hold 1 air vent cut. On all hatch covers gaskets missing. On hold 1 hatch covers corroded through. On hold 2 hatch covers corroded through. On hold 2 hatch entrance cover corroded through. Bulwark corroded through on several places. Inn FCSL STB hull holed. Toilet bulkhead corroded through. Front bridge bulkhead corroded through. FCSL bulkhead corroded through. On FCSL deck corroded through in two places. Emergency lighting inoperative. All portable extinguishers empty. Double skin fuel line on ME missing. Radar transponder missing. MMSI missing. GMDSS radio equipment power supply not available. Ropes in bad condition. Windlass base corroded through. DG 1 inoperative. DG 2 inoperative. Port DG

inoperative. Air compressor insufficient pressure. Steering gear not working properly. Fuel line leaking. Antistatic carpet missing. Captain cabin bulkhead corroded through. Aft bridge bulkhead corroded through.

24/03/2005 Koper

ANNA

General cargo 7620457 2431

Comoros PE Svetoch Odessa Ukraine

Lloyd’s Register of Shipping

Detained for 4 days. 30 recorded deficiencies OWS in dispute. Wheelhouse window glass cracked. On wheelhouse 1 window made of Plexiglas. Rest room window glass cracked. Whistle wire improper. Magnetic compass gimble arrangement sized. STB funnel corroded through. Wheelhouse bulkhead corroded through in several places. Accommodation bulkhead corroded through. Accommodation air vent cover corroded through. Em.gen.room air vent corroded through. Accommodation bulkhead on poop corroded through. Air condition installed out of class conditions. Windlass hydraulic pump leaking. In FCSL 4 frames bent. FCSL door inner gasket holder corroded through. Accommodation door inner gasket holder corroded through. On FCSL bell missing. PS hawser pipe opening holed. Hatch cover fastener missing. AP tank cover not bolted. EM generator room deck corroded through. Emergency fire pump insufficient pressure. Grey water pipes made of rubber. Galley grey water pipe connected with sewage pipe with

rubber pipe. ER bilge dirty. OWS with rubber pipe connection. Under gangway safety net missing. ISM maintenance failed. Main fire line leaking on expansion joint.

04/04/2005 Koper

EMELIE

General cargo 7358688 1859

Georgia Erada Shipping Agency Vlora Albania

International Register of Shipping

Detained for 2 days. 33 recorded deficiencies Charts not up to date. Wheelhouse bulkhead corroded through. STB funnel corroded through. Battery room air vent corroded through. Accommodation air vent corroded through. 2

nd

eng. Cabin window glass crashed. On 2

nd

eng cabin window frame corroded through. On CO2 installation rubber pipes twisted and compressed. CO2 room door corroded through. Food store bulkhead on poop deck corroded through. Main fire line temporary repaired. On hold 1 & 2 PS air vent dampers sized. Hatch covers on hold 1 corroded through. On hold 1 several frames bent. Manhole cover on FP tank not bolted. Hold 1 entrance door corroded through. FCSL door corroded through. On windlass oil leaking. On hold 2 STB air vent holed. In ER PS 2 frames bent. Gauges on sewage tank improper. Grey water pipe temporary repaired with rubber. Antistatic carpet missing. Battery for DG1 inoperative. On DO service tank improper gauges. On ME cylinder No 8 cooling water leaking. ER bilge has to be dried and cleaned. On pumps guards missing. ER fire sensors inoperative. Low pressure flange joints shields missing. Crew

do not use protective personal equipment. Maintenance of ship and equipment failed.

06/04/2005 Koper

MORNING AUTO

Car carrier 7924437 31.587

Panama Seiwa Navigation Tokyo Japan

American Bureau of shipping

Detained for 4 days. 29 recorded deficiencies On wheelhouse air condition installed not par class condition. On captain’s cabin bulkhead air condition installed out of class conditions. On galley skylight glass crashed. On converter room door inner gasket holder corroded through. CO2 safety valve sized. FW air vent STB 1-2 corroded through. FW air vent STB 5-6 corroded through. Spare cabin bulkhead corroded through. STB bridge deck longitudinal corroded through. Accommodation air vent corroded through. Funnel top corroded through. Funnel door corroded through. Deck on acetylene room corroded through. Deck on entrance house on main deck corroded through on several places. STB ER air vent damper sized. STB ramp winch base corroded through. Air vent NV12 damper sized. On deck 1 FW pipe leaking. FP air pipe ball protection corroded through. PS windlass save all corroded through. Deck 4 air vent corroded through. Toilet deck in ER corroded through with water leaking. LO gravity tank with rubber connection. Antistatic carpet missing. FO settling tank gauge blocked. Crew do not wear protective personal equipment. Bilge pump leaking. ME seawater pump leaking. Cooling water on cylinder 1 and 8 leaking.

08/04/2005 Koper

ROSA General cargo 8324282 5317

Panama Kantoh Kaiun Tokyo Japan

Nippon Kaiji Kyokai

Detained for 5 days. 18 recorded deficiencies Emergency fire pump inoperative. OWS inoperative. Handle on aft winch corroded through. Lifeboat not properly maintained. Air vent corroded. Doors corroded through. Galley dirty. Sanitary facilities not hygienic. Crew mess room dirty. Hospital not hygienic. Medical equipment missing. Rubber gasket on ship’s opening bad. Publications missing. Draft not readable. Crew Medical certifications expired. ISM failed.

12/04/2005 Koper

LAND WIND

Ro-ro 7615309 6.172

D.P.R. Korea

TMB Shipping Tripoli Lebanon

Turkish Lloyd Detained for 11 days. 32 recorded deficiencies Monkey bridge deck corroded through. Magnetic compass with air bubbles. Smaller ship whistle inoperative. Two red lights for ship not under command with improper glass. All navigational lights with improper corrugated glasses. On hold air vent door No11 inner gasket holder corroded through. PS hold air vent cover bent. Em. Gen room air vent cover missing. Aft garage air vent cover bent. STB funnel corroded through. STB air vent on upper deck corroded through. Guards on auxiliary boiler hot water pumps missing. ER air vent cut. Hydraulic pipes for ramp temporary repaired. Antistatic carpet missing. Crew do not wear protective personal equipment. On DG3 fuel leaking on high pressure pumps. On day and settling fuel tanks improper gauges. On settling tank gauge blocked with wood. Trimming pump leaking.

Pipes on sludge pump made of rubber. Turbocharger on ME inoperative. Cooling water pipe on compressor made of rubber. Double skin fuel line on ME not as required. Ballast line temporary repaired. Accommodation bulkhead corroded through. FP pipe ball protection missing. Air vent cover on boatswain store corroded through. Rope store cover corroded through. Bridge bulkhead on FCSL deck corroded through. Bulkhead on main garage corroded through. ISM maintenance failed.

13/04/2005 Koper

SMARAGDI General cargo 6718142 1197

St. Vincent & Grenadin.

Kyriakopoulos K&D Eleusis Greece

Hellenic Register of Shipping

Detained for 3 days. 17 recorded deficiencies Charts not up to date. Wheelhouse bulkhead corroded through. Two red lights for ship not under command with improper glass. Magnetic compass with big bubbles. ER skylight corroded through. Funnel doors can not be tightly closed. Steering gear room air vent corroded through. AP air pipe corroded through. In hold 1 several frames bent, corroded through, frames plates bent, frames holed, frame corners corroded through. In hold 1 PS reinforcement plates between frames corroded through. In FCSL PS 7 frames bent. In FSCL bow stem bent. Bulkhead on FCSL corroded through. Frame on FSCL deck corroded through. On rail fence rails missing. Crew do not wear personal protective equipment. ISM maintenance of ship and

equipment failed.

20/04/2005 Koper

BAKI AKAR Oil tanker 8705981 29.998

Turkey Akar Deniz Istanbul Turkey

Det Norske Veritas

Detained for 2 days. 16 recorded deficiencies Accommodation bulkhead on B deck corroded through. STB ER air vent on damper gasket missing. Funnel door corroded through. On gas free fan air vent cover inner gasket holder corroded through. Lower stern light plastic glass melted. Air condition room door corroded through. Accommodation bulkhead on boat deck corroded through. Toilet FW pipe temporary repaired. Galley grey water pipe temporary repaired. Bath grey water pipe temporary repaired. Lub oil tank pipe temporary repaired. FO settling tank and service tank gauges blocked. Cylinder No 6 cooling water leaking. Cooling water connections on ME temporary repaired. Bilge pipe with rubber connection. Abandon drill failed.

23/04/2005 Koper

BSLE EXPRESS

General cargo 7708900 18.792

Cyprus Cyprus Maritime Co. Limassol Cyprus

Bureau Veritas

Detained for 11 days. 14 recorded deficiencies Funnel corroded through. ER skylight corroded through. Em. Generator room door corroded through. Ball protection on air pipe of fuel tank for emergency generator corroded through. Deck outside CO2 room corroded through. Stern navigational light glass cracked. 2

nd engineer

cabin window frame corroded through. Door on hold 3 air vent corroded through. In hold 3 top tank holed in 3 places. TD hatchway damaged. Lead lamps on ER fire sensors

inoperative. Meat room temperature –10°C. Both chain pipes corroded through. SC certificate not valid.

26/04/2005 Koper

STELLA QUARTA

General cargo 7435474 13.661

Panama Lemissoler Ship Management Limassol Cyprus

American Bureau of Shipping

Detained for 4 days. 30 recorded deficiencies Ship security plan not approved. Wheelhouse bulkhead corroded through. Funnel corroded through on several places. Magnetic compass impeded in movements. Hospital bulkhead corroded through. Bridge toilet bulkhead corroded through. On alleyways door glass cracked. Crew mess room bulkhead corroded through. Officers mess room bulkhead corroded through. ER air vents PS&STB corroded through. On master’s and chief engineer cabin bulkheads air condition improperly installed. Mast house entrance cover corroded through. Both chain pipes corroded through. On FCSL bell missing. On PS windlass bed plate corroded through. Main collision bulkhead holed. In FCSL main deck cut with cutting machine. FP valve rod cut and removed. Stem frame corner corroded through. Emergency FP exhaust air vent cover inner gasket holder corroded through, dogs missing. ER exhaust air vent cover inner gasket holder corroded through. ER bulkhead corroded through. Steam pipe for FO heating leaking. ER emergency exit obstructed. Drainage pipes from separators room made of rubber. In steering gear room hull dented. QCV on FO day and service tanks

inoperative. Steering gear room hatchway corroded through. ER fire dampers wires disconnected. ISM maintenance failed.

29/04/2005 Koper

KAIROS

General cargo 6908864 1798

St. Vincent & Grenadines

Split Ship Management Split Croatia

International Naval Survey Bureau

Detained for 5 days. 33 recorded deficiencies Bulwark frames cracked. PS bridge bulkhead holed. On wheelhouse windows wipers missing. Monkey bridge deck temporary repaired not under class supervision. Two red lights for ship not under command with improper glasses. Magnetic compass with big air bubble. ER store bulkhead corroded through. On PS lifeboat line backeted round the outside boat missing. ON PS lifeboat stern cover to be fixed. Steering gear room air vent damper sized. Deck on gangway buckled. In steering gear room one frame heavy bent. OWS with illegal piping. OWS out board pipe connection with additional valve. On FO tank gauges blocked with wires and with rubber connections. ME Cooling water on Cylinder no6 leaking. Poop store hatchways covers corroded through. Longitudinal frame on poop deck corroded through. FW air pipe head missing. On entrance bulkhead flanged pipe installed. Sludge tank air pipe corroded through. On both sludge tank air pipes nets corroded through. Hatch cover hydraulic cylinder heavy leaking. 11 hatch coaming drainage boxes corroded through. In hold 2 PS 9 frame corners detached. In hold 2 front longitudinal

bulkhead corroded through. In hold 3 sixteen frame corners detached. In FCSL hull dented. IN FCSL 3 frames bent. All holds air vents fans inoperative. Hold 3 door bent. ISM Maintenance of ship and equipment failed.

06/05/2005 Koper

BLUE MOON I

Ro – ro 7407037 5186

Panama Marine Conquest Piraeus Greece

Polski Rejstr Statkow

Detained for 2 days. 7 recorded deficiencies. On FCSL bell missing. Emergency fire pump inoperative. QCV on fuel tank for emergency fire pump inoperative. STB lower hold 2 frames bent 1 frame corner completely cracked. FO settling tank with rubber pipe connection. Outlet piping on OWS improperly installed.

17/05/2005 Koper

ANAMARIA I

General cargo 8507482 4708

St. Vincent & Grenadines

Bandic Split Croatia

Lloyd Register of Shipping

Detained for 7 days. 13 recorded deficiencies ISM audit. Main fire line leaking. OWS inoperative. Air vent corroded through. ER fire detectors inoperative Hatch covers corroded through. Self ignition lights inoperative. Catwalks corroded through. Hydraulic on winches leaking. Hydraulic of hatch covers leaking. Fire hoses leaking. ER bilge dirty. Life boat stern post corroded through.

30/05/2005 Koper

THERESE

General cargo 7206756 3015

Panama Split Ship Management Split Croatia

Lloyd Register of Shipping

Detained for 5 days. 32 recorded deficiencies ORB not properly filed. In wheelhouse one wiper inoperative. Stern anchor light with improper glass. Casing on accommodation air vent corroded through. Master cabin bulkhead corroded through. Master cabin air vent corroded through. Chief officer cabin bulkhead corroded through. Front bridge bulkhead corroded through. In

FCSL one frame holed. FP tank cover not bolted. Gauge on port generator fuel tank improper. Fuel tank for fire pump generator half full. In hold 1 several frame plates bent and holed. In hold 2 longitudinals corroded through. In hold 1 beams corroded through. In hold 1 two frames plates cracked. Frames on hatch covers on hold 1 cracked. PS chain pipe corroded through. In hold 2 several frame plates bent and holed. In hold 2 three frames detached from top tank. In hold 2 two frame plates cracked. On aft hold 2 entrance one bracket corroded through. On hold 2 all hatch covers frames corroded through. In steering gear room one frame bent. In steering gear room hull dented. Antistatic carpet missing. FO alarm system for ME improperly installed. Low pressure flanged joints shield missing. Improper outlet discharge for OFE fitted. Tunnel fire hydrant temporary repaired. Reductor cooling water pipe made of rubber. Food quantity insufficient.

07/06/2005 Koper

EGYPTIAN PRIDE Ro - ro 8708622 7363

Egypt Norna Shipping Alexandria Egypt

Registro Italiano Navale

Detained for 1 day. 14 recorded deficiencies 2 crew members with expired medical examinations. In wheelhouse 1 window wiper inoperative. Galley hood dirty. Crew do not wear personal protective equipment. Cargo securing manual incomplete. ER bilge dirty. Bilge under auxiliary engines dirty. Under sewage machine

alleged hull leaking. Sewage non return valve temporary repaired. On OWS outlet illegally flange fitted. On low pressure line flange joints shields missing. In ER sanitary pipe disconnected. In ER antistatic carpet missing. Piping on auxiliary boiler leaking.

08/06/2005 Koper

MED WIND

General cargo 7711517 1842

Panama Nikolakis Shipping Athens Greece

Hellenic Register of Shipping

Detained for 9 days. 35 recorded deficiencies Wire for ER fire damper torn. Bulkhead on air condition room corroded through on several places. Funnel door corroded through. Wheelhouse bulkhead corroded through. Magnetic compass with air bubbles. Paint room bulkhead corroded through. Bow stem bent. In FCSL one gusset plate between frames bent. In FCSL anchor washing pipe made of rubber. In FCSL air pipe corroded through. In FCSL 1 frame bent. In hold FWD all gusset plates between frames corroded through. Several frames cut off. In hold FWD 2 frames cracked PS. In hold PS 3 frames corroded through. In hold FWD STB 3 frames corroded through. Beams bent and detached. Diagonal longitudinal with frame corner detached. Beam under hatch coaming cracked. In FCSL air vent holed. In FCSL PS air vent corroded through. On FCSL ship’s bell to small. Crew do not wear personal protective equipment. Emergency fire pump insufficient pressure. Air vent on DG room corroded through. In ER bulkhead corroded through. Fuel pipe made

of rubber. FW pipes on pumps made of rubber. OWS on pump made of rubber. In ER 2 frames corroded through. OWS outlet pipe improperly installed. In ER STB 2 frames bent. DG1 cooling water pipe temporary repaired. In ER main fire line temporary repaired. Galley hood dirty. ISM failed.

17/06/2005 Koper

FALAK G

General cargo 7208522 1454

Slovakia Sea Cristal Navigation Piraeus Greece

Bulgarian Register of Shipping

Detained for 7 days. 27 recorded deficiencies Both wheelhouse wipers inoperative. Wheelhouse bulkhead corroded through. Both side navigational lights with glass cracked and emergency lights missing. One red light for ship not under command damaged. PS boat deck corroded through. Front bridge bulkhead corroded through. Inner side of save all corroded through. On fuel air pipes ball and ball protection missing. Hydraulic line temporary repaired in several places. In hold top tank poorly temporary repaired in several places. In hold several frames damaged. In hold several frames detached from top tank. In hold several frames corroded through. Hatch coaming corroded through. Hatch coaming damaged. Web frame corroded through. Bulkhead on WB tank 4 temporary repaired with concrete. In hold sounding pipe holed. Hold air vent dampers holed. PS chain pipe heavily cracked. Emergency fire pump insufficient pressure. DG cooling water leaking. Fire hose used for

cooling water pipe. QCV on service tank inoperative. OWS inoperative. ER emergency light inoperative. ISM maintenance failed.

17/06/2005 Koper

BLUE MOON I

Ro –ro 7407037 5186

Panama Marine Conquest Piraeus Greece

Polski Rejestr Statkow

Detained for 1 day Ship alleged for pollution in port of Koper

17/06/2005 Koper

MSC ANASTASIA

Container ship 7020542 16670

Panama Mediterranean Shipping Italy

Germanischer Lloyd

Detained for 1 day Ship alleged for pollution in port of Koper.

21/06/2005 Koper

MEX

General cargo 7915591 2981

Comoros Medway Shipping Piraeus Greece

Polski Rejestr Statkow

Detained for 4 days. 31 recorded deficiencies Minimum manning certificate not properly filled. Iopp certificate not properly filled. Charts not up to date. Funnel corroded through. Wheelhouse bulkhead corroded through. Boat deck corroded through. Stern light with improper glass. Fire hose leaking. Emergency fire pump insufficient pressure. Five cargo winches with base construction corroded through. In hold 2 three frames corroded through. Web frame corroded through. Air vent trunk corroded through. Hatch entrance corroded through. FCSL door corroded through. Chain pipe in FCSL corroded through. Paint locker with no ventilation. IFCSL last frame corroded through. The last but one frame in FCSL corroded through. In FCSL two gusset plates corroded through. Fore peak valve sized. On bulwark 3 frames corroded through. In steering gear

room 2 illegal flange outlet installed. Auxiliary port generator exhaust pipe not insulated. All fire extinguishers expired. All life rafts expired. Class certificate improperly filled. ISM maintenance failed.

22/06/2005 Koper

AL KARIM

General cargo 7427611 1949

Georgia Tarous Shipping Tartous Syria

Rusian Maritime Register of Shipping

Detained for 3 days. 14 recorded deficiencies Crew not use personal protective equipment. Wheelhouse bulkhead corroded through. Navigational lights alarm inoperative. Funnel CO2 extinguisher empty. ER air vent corroded through. ER air vent cover corroded through. Front bridge bulkhead corroded through. Chain pipe corroded through. In FCSL 12 frames bent. Hatchway cover corroded through. QCV on emergency fire pump fuel tank inoperative. Fuel tank improper gauge. ER fire sensors inoperative. In ER several frames bent.

27/06/2005 Koper

WAEL F

General cargo 7638959 3898

Syria Mudalal Navigation Latakia Syria

Bureau Veritas

Detained for 4 days. 26 recorded deficiencies Crew do not wear personal protective equipment. Charts not up to date. Battery room air vent corroded through. Two-accommodation air vent on monkey bridge corroded through. ER air vent corroded through. ER skylight corroded through. Battery room door corroded through. Chart room bulkhead corroded through. Both block plates corroded through. Three lifeboat davits corroded through. Captain cabin bulkhead improperly pierced. Air condition room bulkhead corroded through. BW tank no 3 air pipe corroded through. On mast house two DO air

pipes corroded through. Hydraulic pipes on mast house and FCSL leaking. Anchor ball improper size. In FCSL drain pipe corroded through. In hold 1 STB eleven frame corners detached. In hold 1 PS seventeen frame corners detached. In hold 1 four frame corners cracked. In hold 2 six-frame corners detached. Gauge on lub oil tank improper. OWS inoperative. Bilge piping not as required. Meat room temperature – 6 °C. ISM maintenance failed.

11/07/2005 Koper

MURVET ANA

General cargo 8202939 5962

Turkey Bayktar Gemi Istanbul Turkey

American Bureau of Shipping

Detained for 2 days. 13 recorded deficiencies Funnel corroded through. On second mast house hydraulic leaking. Air vent non hold 2 corroded through. PS air vent on hold 1 not bolted. Spilled DO on DG room. Fuel tank for emergency generator leaking. Gauge on sewage tank improper. DO return pipe on DG made of rubber. QCV on FO settling tank inoperative. Two gusset plates in hold 1 damaged. FO drain pipes connected to bilge. Bilge and sludge piping not as required. OWS inoperative.

14/07/2005 Koper

HAN

General cargo 7634044 2453

Panama

Genta Genel Istanbul Turkey

Lloyd register of Shipping

Detained for XX days. 33 recorded deficiencies Both wipers in wheelhouse inoperative. Green side navigational light glass cracked. Red side navigational light glass cracked, Stern navigational light glass cracked. Mainmast navigational light glass cracked. Two red lights for ship not under command with improper glass. All navigational lights with improper

glass. Magnetic compass with air bubbles. CO2 room and alleyway doors inner gasket holder corroded through. ER air vent PS and STB corroded through. Galley air vent cover inner gasket holder corroded through. Crew mess room air vent cover inner gasket holder corroded through. Aft hatch entrance covers corroded through. Rope store cover corroded through. Paint room air vent missing. Both anchor stoppers bar missing. On fuel tank for emergency fire pump QCV missing. Emergency fire pump insufficient pressure. In FWD hold six longitudinal reinforcements corroded through. On PS longitudinal cracked in two places. PS frame corners corroded through, one frame damaged. STB three frame reinforcement corroded through. STB one frame corroded through, two frames bent. Top tank no 28 corroded through. ON FWD bulkhead corroded through. Hatch covers corroded through, inside frames and corners corroded through. FWD lower part of hatch coaming cracked. Frame 1 and 2 damaged, hull indented. In lower alleyway lighting inoperative. Alleged illegal pipe connection on bilge and OWS outlet fitted. ER fire sensor inoperative. ISM maintenance failed.

18/07/2005 Koper

OLA

General cargo

Russia Morincaps Moscow

Russian Maritime Register of Shipping

Detained for 2 days. 12 recorded deficiencies No emergency navigational lights fitted.

6919100 2478

Russia ER skylight corroded through. In wheelhouse wipers inoperative. Wheelhouse bulkhead corroded through. Stern light with improper glass. Anchor lights with improper glasses. Front bridge bulkhead corroded through. Fuel lines failure alarm on both engines inoperative. Grey water pipe temporary repaired. ER and galley fire sensors inoperative. Emergency fire pump room cover corroded through. Local start of emergency fire pump inoperative.

25/07/2005 Koper

NORDIC BAY

Reefer 7909803 7142

St Vincent & Grenadines

Ost-West Handel Bremen Germany

Russian Maritime Register of Shipping

Detained for 3 days. 28 recorded deficiencies Accommodation bulkhead corroded through. Both ER air vent corroded through. PS ER air vent damper sized. ER skylight cover corroded through. PS accommodation door inner gasket holder corroded through. Gen exhaust fan cover twisted on hinge. PS lifeboat bilge pump inoperative. Chillier fuel pipe improper. Mast house bulkhead corroded through. Mess room bulkhead corroded through. DBT 1 air pipe ball protection corroded through. FCSL store room air vent corroded through. CO2 room bulkhead corroded through. DO day tank QCV inoperative. Crew do not use personal protective equipment. ER fire sensors inoperative. Steam cooling pipe leaking. Auxiliary engines 2 & 3 cooling water leaking. Emergency fire pump inoperative. ME piston cooling pumps inoperative. ER bilge

dirty. Sewage pipe connected to bilge. Stuffing boxes on ME leaking. Stuffing box connected with rubber pipe to oil filter tank. Fuel leaks alarm on ME inoperative. Abandon drill failed. ISM maintenance failed. ISM preparedness failed.

08/08/2005 Koper

NIKA

General cargo 7411600 2.570

St. Vincent & Grenadines

Nika Shipping Co. Rijeka Croatia

International Naval Survey Bureau

Detained for 5 days. 2 recorded deficiencies. Cracked twin deck. ISM

02/09/2005 Koper

ROSSEL CURRENT General cargo 7819931 16.992

St. Vincent & Grenadines

Navalmar Lanka Ratmalana Sri Lanka

Det Norske Veritas

Detained for 5 days. 28 recorded deficiencies On PS scuttle window glass missing. On wheelhouse one wiper inoperative. Magnetic compass with air bubble. Funnel door corroded through. ER deck PS and STB corroded through. STB ER air vent corroded through. Accommodation bulkhead corroded through. STB life boat repaired with pour pen, interior holed and cracked. On chief mate window illegal installation of air condition pipe. On 2

nd

mate cabin window bulkhead holed. Throttle valve on lifeboat engine inoperative. Wooden wedges on lifeboat davits cracked. Frame of the accommodation air vent cover cracked. FW air pipe cover detached. Frame on DG room air vent cover detached. On DG fuel tank QCV missing. Aft ER air vent casing corroded through. Steward cabin bulkhead corroded through. FO sounding pipe cap holed. Two FO sounding pipes with wooden stopple. Front

bridge bulkhead cracked. Hold air vent CC4 corroded through. Hold air vent C5 corroded through. Hold air vent CC2 corroded through. In hold one STB 5 frame corners bent on Ps 2 frame corners bent. In hold one FWD on PS & STB severe hull corrosion. In hold one STB 4 frames plates bent. On FCSL bell’s clapper missing.

12/09/2005 Koper

BOSPHORUS PRODIGY

General cargo 8415158 3.062

Antigua & Barbuda

Iskomarine Shipping and Trading Istanbul Turkey

Germanischer Lloyd

Detained for 3 days 10 recorded deficiencies Crew do not use personal protective equipment. ER bilge dirty. Magnetic compass with air bubble. PS hatchway cover corroded through. Bell missing. ME jacketed pipes missing. OWS inoperative. OWS improper return pipe. ER fire detectors inoperative. ER emergency lights inoperative.

15/09/2005 Koper

LADY RASHA

General cargo 7223041 1.777

Korea DPR

Quality Ship management Banias Syria

Dromon Bureau of Shipping

Detained for 3 days. 20 recorded deficiencies Charts not up to date. Red side light glass cracked. Spare red side light inoperative. Spare side green light not properly fixed. Wheelhouse bulkhead corroded through. Bridge toilet bulkhead corroded through. Funnel corroded through. Funnel air vent covers sized. Magnetic compass with air bubbles. Captain toilet bulkhead corroded through. Pilot cabin door corroded through. Pilot cabin bulkhead corroded through. Captain cabin bulkhead corroded through. In hold 1 PS one frame corroded through. In hold 1 one frame plate detached. In hold 1 PS one frame

plate cracked. FWD hold 1 air vent damper holed. Main fire line holed. Safety valve on main fire line not tested. Maintenance of ship and equipment failed.

16/09/2005 Koper

VOLGO BALT 242

General cargo 8230560 2.516

Russia Gloria Co. Odessa Ukraine

Russian Maritime Register of Shipping

Detained for 5 days. 26 recorded deficiencies Chart room deck corroded through. Battery room air vent cover missing. Funnel deck corroded through. Skylight casing corroded through. Chart room bulkhead corroded through. DG deck corroded through. Computer room bulkhead corroded through. Ch. eng cabin bulkhead corroded through. Master cabin bulkhead corroded through. Front bridge bulkhead corroded through. Three deck supports corroded through. Hull corroded through. ER air vent corroded through. On hold 2 hatch cover cracked. In hold 2 aft all gusset plates damaged. In hold 2 on aft bulkhead all frames detached and bent. In hold 2 STB hatch coaming reinforcement cracked. Both chain pipes damaged. In hold 4 FWD hatch coaming holed. All connection lines to alarm tank on both ME detached. FW pipe connection between pump and tank made of rubber. Paralel synchronisation of DG inoperative. Crew do not use personal protective equipment. ER fire sensors inoperative. ISM maintenance failed.

19/09/2005 Koper

ALKOR

General cargo 7516709

Namibia VEMA Shipping Co. Athens

Bulgarski Koraben Registar

Deatined for xx days. 28 recorded deficiencies Cabin side scuttle glass cracked. Crew do not use personal protective

3.604 Greece equipment. IOPP supplement entries missing. Wheelhouse bulkhead corroded through. In wheelhouse one wiper inoperative. Two red lights for ship not under command with improper glasses. Funnel corroded through. Chart room bulkhead corroded through. Bridge deck over ER corroded through. Boat deck corroded through in several places. Stern light with improper glass. Port DG filling fuel line temporary repaired. WBT 1 air pipe corroded through. DT air pipe corroded through. Anchor light glass cracked. Both chain pipes cracked. DO7 air pipe corroded through. Galley bulkhead corroded through. Sanitary without water taps. Sewage pipe temporary repaired with wooden plug. On DG No1 generator missing. Parallel synchronisation between DGs inoperative. Settling tank drain pipe connected to the bilge. High and low suction chest pipes not as required. There are several outboard valves with flanges, which can be used for illegal discharge. Outlet pipe on ME alarm fuel tank leaking. ISM maintenance of ship and equipment failed.

23/09/2005 Koper

DORIAN STAR General cargo 7632981 15.464

Cyprus Hellenic Star Shipping Athens Greece

Russian Register of Shipping

Detained for 3 days. 18 recorded deficiencies Sanitary air vent corroded through. Wheelhouse bulkhead corroded through. Wheelhouse window frame corroded through. ER air vent corroded through. Funnel deck corroded through. Mess

boy cabin bulkhead corroded through. Galley window cracked. Accommodation air vent trunks PS&STB corroded through. Hatch cover on hold 4 corroded through. Hatch covers on hold 3 corroded through. Hatch covers on hold 2 corroded through. FOT 2S air pipe corroded through. FCSL bulkhead corroded through. Package holder on main deck accommodation door corroded through. On all DGs fuel alarm tanks connected with rubber pipes. Fuel alarm on DG inoperative. Antistatic carpet missing.

03/10/2005 Koper

HEIDI II Bulk carrier 7614147 9.029

Georgia Qawareb Ship Management Dubai U.A.E.

International Register of Shipping

2 Detained for XX days. 82 recorded deficiencies Hull corroded through. Ship using tank not recorded in IOPP. Captain cabin window cracked. In wheelhouse both screen wipers inoperative. Both VHF/DSC inoperative. One radar transponder inoperative. MF/HF radio installation inoperative. Reserve source of energy inoperative. Side and stern navigational lights inoperative. All emergency navigational lights inoperative. All navigational lights with improper corrugated glasses. Magnetic compass with big bauble. Deck in battery room corroded through. Wheelhouse bulkhead corroded through. Funnel door corroded through. Funnel corroded through in several places. ER skylight frame missing, glass cracked. Several bulbs missing, accommodation and

outside lighting poor. Elevator tunnel cover corroded through. Captain cabin bulkhead corroded through. Wheelhouse deck corroded through. Emergency DG room air vent covers missing. Galley store air vent damaged. Entertainment rooms bulkhead corroded through. Mess room bulkhead corroded through. Mess room deck corroded through. Emergency DG inoperative. Electrician cabin bulkhead corroded through. AB cabin bulkhead corroded through. On several sounding pipes caps missing. Stores air vent corroded through. Front and side bridge temporary repaired with tape. STB door on main deck corroded through. Tank FO 10 STB air pipe corroded through. Tank 9 S Top air pipe corroded through. Tank 8S top air pipe corroded through. Tanks 7P DB air pipes corroded through. Tank 6 DB top air pipes corroded through. Tank 9 P air pipe corroded through. Tank 5 DB air pipe corroded through. Tank 10 S top air pipe corroded through. Tank 3S top air pipe corroded through. Tank 3C FO air pipe corroded through. On main deck several scuppers blocked. Main fire line temporary repaired in two places. Tank 6S top air pipe corroded through. Boatswain store door corroded through. Boatswain store room bulkhead corroded through. Paint room door corroded through. FCSL door corroded

through. FCSL deck corroded through. On FCSL bell missing. Bulwark cracked. On hold 5 hatch coaming one frame corroded through. ER bulkhead in accommodation alleyway corroded through. Two FW pumps inoperative. Substituted FW pump improperly installed with rubber pipes. OWS with improper pipes installation. Illegal outboard discharge installed. Safety valve on auxiliary boiler inoperative. Several pumps in ER leaking. ER alarm in bilge inoperative. Hydrophore deck cracked. ER dirty. One air compressor inoperative. Oil filling pipe for ME made of rubber. ON ME jacketed high pressure lines missing. On all DG jacketed high pressure lines missing. On DG 1 fuel leaking. DG 3 inoperative. DG 2 can not be synchronised with other DG. Emergency light inoperative. DO Tk 22 drain improper. DO Tk 29 high level alarm inoperative. QCV on all fuel tanks inoperative. Steering gear room dirty. Emergency fire pump with no pressure. Life boat engine can not start manually. Bilge pump in lifeboat inoperative. Boat drill failed. ISM maintenance of ship failed. Emergency preparedness failed.

10/10/2005 Koper

TERRA General cargo 7366025 3.681

Slovakia Caspi Cargo Lines Haifa Israel

Lloyd Register of Shipping

Detained for 3 days. 6 recorded deficiencies. One of red lights for ship not under command glass cracked. Stern anchor light with improper glass. Steering

gear air vent corroded through. Both chain pipes corroded through. On OWS illegal discharge fitted. On ME collecting of leakage tank with no alarm.

11/10/2005 Koper

KRIOS General cargo 7434729 1.637

Panama Nagina Shipping & Trading Piraeus Greece

Hellenic Register of Shipping

Detained for 4 days. 35 recorded deficiencies Entries of sludge operations missing. Charts for north Adriatic not up to date. MF/HF and Inmarsat installed but not recorded in Record of equipment form (R). Battery for portable VHF expired. ER air vent corroded through. Funnel air vent cover corroded through. Funnel holed. Front railing on monkey bridge detached. Limit switch not properly installed. On STB lifeboat shackle on aft tackle to weak. Captain cabin bulkhead corroded through. Office bulkhead corroded through. Cover on aft rope store hatchway not possible to close. Galley bulkhead corroded through. Galley window cracked. FW air pipe net missing. Hatch covers corroded through. On FCSL anchor light glass cracked. Side anchor lights with improper glass. Three dogs on FCSL rope store cover heavy bent. PS chain pipe temporary repaired with concrete. Paint not stowed in paint room. On emergency DG guard missing. Emergency fire pump insufficient pressure. Battery box for DG improper. Antistatic carpet missing. In hold FWD one longitudinal corner plate detached. OWS inoperative. Illegal fresh water pipe to oil content meter installed. In steering gear room

illegal discharge installed. ER fire sensors inoperative. In ER hull indented, one frame damaged. Abandon ship drill failed. ISM maintenance of ship and equipment failed. Emergency preparedness failed.

18/10/2005 Koper

MARTINA M General cargo 8414283 2.831

St. Vincent & Grenadines

Bandic d.o.o. Split Croatia

Croatian Register of Shipping

Detained for 2 days. 8 recorded deficiencies. Emergency fire pump inoperative. Life rafts expired. Lifebuoy not as required. Line throwing appliance expired. EPIRB not properly installed. Echo sounder inoperative. Charts not up to date. Hydraulic pipes leaking.

25/10/2005 Koper

HILL General cargo 6828686 14.385

Liberia Aptera Maritime Piraeus Greece

Lloyd’s Register of Shipping

Detained for 5 days. 23 recorded deficiencies Sludge tank to be emptied before departure. Radio room deck corroded through. All around the old bridge bulkhead corroded through. Galley air vent corroded through. Air vent cover A-28 sized. On air condition room door gasket holder corroded through. On galley window improper vent installed. Air vent frame on galley bulkhead corroded through. FO 5 STB air pipe ball protection corroded through. DB 4 air pipe corroded through. DB 4/5 air pipe corroded through. On FCSL bell missing. In hold 4 entrance inner bulkhead corroded through. Two frames on bulkhead in aft rope store corroded through. Severe wastage of AP top tank deck. Grey water pipe from toilet made of rubber. Emergency fire pump insufficient pressure. Crew do not use personal protective

equipment. Four illegal discharges fitted. Half funnel deck, 100% of old bridge deck and boat deck temporary repaired with concrete. In STB lifeboat hand bilge pump inoperative. Abandon ship drill failed. ISM emergency preparedness failed.

28/10/2005 Koper

MARA General cargo 7015509 1.090

DPR Korea

El- Amira Ravenna Italy

Dromon Bureau of Shipping

Detained for 5 days. 28 recorded deficiencies Crew do not use personal protective equipment. Steering gear room entrance cover gasket holder corroded through. Bilge holding tank installed on deck. Improper oil water discharge pipe installed. Head of air vent for pump room missing. On hatch 2 package holders on hatch covers corroded through. On hatch 2 frames on hatch covers corroded through. Ball protection on air pipe BW 4 PS corroded through. On hatch one hatch covers frames corroded through. On hatch one hatch covers corroded through one cracked. On hatch two both FWD hatch coaming reinforcement corners corroded through. Both chain pipes corroded through. In former CO2 room five frames heavy bent. In former CO2 room hull indented. All bridge infrastructure bulkhead bad connected with deck. Last frame PS detached. STB hawser pipe connected with rubber pipe for anchor washing. In former CO2 room entrance beam corroded through. Hatch way entrance in former CO2 room corroded through. Boatswain store entrance cover corroded

through. Paint room without air vent. Ball protection on WB 1 air pipe corroded through. Possible illegal discharge installed on STB hull before ER entrance. Provision quantity insufficient. Sea water supply pipe made of rubber. Fresh water pipe for ME made of rubber. ISM maintenance of ship failed.

03/11/2005 Koper

NIKA General cargo 7411600 2.570

St Vincent & Grenadines

Nika Shipping Co. Rijeka Croatia

International Naval Survey Bureau

Detained for 3 days. 13 recorded deficiencies MF/HF radio installation inoperative. Two artificial holes in funnel. Ball protection on PW air pipe corroded through. On Ps FCSL on hull insert with no class approval. STB chain pipe damaged. Gauges on tank blocked. Three illegal discharges fitted. On tank 12 manhole cover illegal pipe with valve installed. On sewage tank illegal pipe installed. On cylinder No5 cooling water leaking. Ballast pump gland leaking. OWS inoperative. On OWS additional pipe fitted.

04/11/2005 Koper

SOL TRADER General cargo 7504184 1.583

St Vincent& Grenadines

Alpex Rijeka Rijeka Croatia

Bureau Veritas

Detained for 2 days. 23 recorded deficiencies Crew number not in compliance with minimum safe manning certificate. Radio record of equipment missing. Supplement of IOPP missing. Navtex inoperative. ER air vent corroded through. Quadrants correctors not fixed. On AP FW air pipe net missing. In FCSL STB last frame cracked. In EDG room 5 consecutive frames and corners bent. Nozzle and hose not of same size. On fuel tank for EDG gauge missing. Batteries for EDG not in

place. On FCSL bell missing. Ball protection on aste tank corroded through. In ER five grey water pipes made of rubber. In steering gear room fire sensor covered. Emergency fire pump insufficient pressure. OWS inoperative, pipes improperly connected to outlet. Pump for sewage plant missing. Sea chest air exhaust made of rubber. Fuel filters connected with service tank with rubber pipe. Escavator fuel pump in ER improper installed. Hatch covers corroded through.

08/11/2005 Koper

ANAMARIA I General cargo 8507482 4.708

St. Vincent & Grenadines

Bandic d.o.o. Split Croatia

Lloyd’s Register of Shipping

Detained for 3 days. 36 recorded deficiencies Original of SMC not on board. Original of ISSC not on board. Two black ball for ship not under command improper size. Monkey bridge deck corroded through. Two air vents on radio room corroded through. Wheelhouse air vent corroded through. Captain cabin bulkhead corroded through. Funnel corroded through. ER working opening not protected. ER working opening not protected. Hydraulic pipes on monkey bridge deck temporary repaired with concrete. Empty cabin bulkhead corroded through. On funnel illegal air vent made of half drum. Stern light cables not fixed. On several air pipes covers rubber gasket missing. On poop STB rail holed. On officers window glass cracked. Hold 2 air vent corroded through. On sludge discharge pipe international shore connection fitted. On stb ballast pipe detached.

DB3 STB & PS air pipes ball protections corroded through. Hatch covers frames corroded through. Hold drainage improper. DO tank air pipe corroded through. On main entrance over head deck corroded through. Place over steering gear room oily and slippery. Three illegal discharge fitted in ER. ME lub oil tank made from drum and rubber pipes. DG no 3 dirty with oil leakage. On compressor sea cooling water pipes made of rubber. Compressor outlet pipe not as required. On ballast tank manhole valve with rubber pipe installed. OWS pipes made of rubber. ER fire sensors inoperative. In washing room air pipe temporary repaired with concrete. ISM maintenance failed.

15/11/2005 Koper

FRAU NANCY General cargo 7128057 1.887

Korea DPR

Dream Maritime Alexandria Egypt

Dromon Piraeus

Detained for 43 days. 57 recorded deficiencies One VHF/DSC inoperative. CSR and record of equipment missing. Original of SCM not on board. Original of IOPP not on board. Original of ISSC not on board. Original of LL not on board. Original of sage manning not on board. On STB one side scuttle window without glass. Chart No 1471 missing. On STB two heavy hull indention. Funnel corroded through. Side green light cracked. All glasses on ER skylight crashed. Funnel air vent cover corroded through. Back wheelhouse bulkhead corroded through. Galley skylight corroded through. Alleyway door threshold corroded through. Bridge wing deck

corroded through. Fuel save all on boat deck holed. Air condition bulkhead corroded through. Air vent cover on air condition room corroded through. Steering gear room hatchway cover corroded through. Provision room air vent cover corroded through. On FCSL rope store cover corroded through. STB chain pipe corroded through. Windlass base frame corroded through. Emergency DG inoperative. Emergency fire pump inoperative. EDG deck oily and slippery. Seven hatch coaming frames on hold 1 corroded through. Aft derrick on hold 1 damaged. Plates on derrick lower block corroded through. Seven hatch coaming frames on hold 2 corroded through. FWD hatch coaming on hold 2 damaged. In hold 2 PS ten frames corroded through and detached. Stern bulkhead in hold 2 five frames bent. In hold 2 STB nine consecutive frames heavy bent. FWD beam brackets corroded through. FWD two longitudinal corroded through. Bulkhead between hold 1 & 2 holed. Food compressor inoperative. Suction valve for FP cracked. AP air pipe corroded through. In paint room hull corroded through. Fuel tanks gauges blocked with wire. In ER several steel pipes temporary substituted with rubber pipes. On fuel oil tank QCV inoperative. DG No 2 inoperative. Cooling water on ME cylinder No

2 leaking. Fuel leaking alarm not installed. Bilge pump inoperative. Several drainage rubber pipes connected to open manhole of tank No 5. ER fire sensors inoperative. ER and ER bilge not clean. Illegal discharge fitted on OWS outlet pipe. Crew does not wear personal protective equipment. ISM maintenance of ship failed.

17/11/2005 Koper

DEHNI – T Ro-ro ship 7615309 6.172

Korea DPR

TMB Shipping Tripoli Lebanon

Register of Shipping

Detained for 2 days. 4 recorded deficiencies. Illegal discharge fitted. ER bilge full. Crew with no medical examinations. Charts missing.

18/11/2005 Koper

JAREF General cargo 8606111 8.195

Libya General National Transport Tripoli Lybia

Nippon Kaiji Kyokai

Detained for 4 days. 12 recorded deficiencies No original IOPP certificate on board. Sanitary air vent corroded through. Radio room air vent corroded through. ER air vent corroded through. Standard discharge connection with additional pipes fitted. Fuel leaking alarm on DG 1 inoperative. On DG1, DG2 and DG 3 fuel leaking directly to bilge. OWS inoperative. OWS pump used to pump sludge and bilge water. Illegal discharge connection fitted on OQS outboard line. Crew does not wear personal protective equipment. Emergency fire pump with insufficient pressure.

21/11/2005 Koper

OANA

General cargo 8222408 5.931

Romania Cosena Constanta Romania

Lloyd’s Register of Shipping

Detained for 2 days. 12 recorded deficiencies Chart room bulkhead corroded through. Al four ER air vent corroded through. Front bridge bulkhead corroded through. Possible illegal discharge fitted on outboard pipe. In

steering gear room possible illegal discharge fitted. Additional filling pipe fitted on ballast line. Shields on fuel pipes slack. ME sump tank filling pipe made of rubber. Filling pipe for emergency fire pump tank made of rubber. Crew do not wear personal protective equipment.

29/11/2005 Koper

MR LULU

General cargo 7226627 1.432

Georgia ISM Group Tartous Syria

International Register of Shipping

Detained for 2 days. 21 recorded deficiencies Chart No 1471 missing. Wheelhouse window cracked. Captain cabin and wheelhouse bulkheads perforated by air condition cables. Magnetic compass gible blocked because is to large. Funnel corroded through. Threshold entrance bulkhead corroded through. Electric cable for freezer box improper. Both standard discharge connections with additional valves and pipes fitted. Anchor ball improper size and shape. On FCSL bell missing. Hold 1 & 2 air vent dampers sized. PS anchor washing line damaged and detached. Air vent cover on boatswain store missing. Air vent cover on STB FWD hold 1 missing. On hold 1 air vent corroded through. Former fuel tank bottom corroded through, frames heavy corroded and detached. In ER one frame heavy bent. ER fire sensor inoperative. DO fuel tank with improper gauge. Emergency fire pump with insufficient pressure. Hoses’ coupling not properly fixed.

01/12/2005 ASALAH II Korea Khalid Hijazi Register of Detained for 7 days.

Koper

Live stock 6421581 498

DPR Amman Jordan

Shipping 30 recorded deficiencies In wheelhouse both wipers inoperative. Charts missing. Captain cabin window glass cracked. Monkey deck temporary repaired with concrete. Magnetic compass with improper gible. Binacle not fixed on deck. Two red lights for ship not under command with improper glasses. Navigational lights with improper corrugated glasses. ER skylight corroded through. Accommodation air vent corroded through. All hold air dampers sized. Galley door corroded through. Frame on saloon window corroded through. FW filling pipe temporary repaired. In tween deck three frames bent. In TD 10 frames corroded through. Gusset plates between frames corroded through. TD PS 10 frames corroded through. LH 10 frames corroded through. FCSL deck corroded through. Both FCSL air vents corroded through. QCV on EDG inoperative. EDG inoperative. PS hawser pipe cracked and holed. QCV on settling tank inoperative. ER overhead deck corroded through. DG cooling water pipes made of rubber. Compressor outlet pipe made of rubber. On ME double skin pipes missing. Emergency lightning inoperative.

01/12/2005 Koper

HIZIR KARAER

General cargo 8139302 856

Turkey Marmara Adasi Istanbul Turkey

Turkish Lloyd Detained for 2 days. 12 recorded deficiencies Notice of mariners missing. On ballast tanks air pipe covers missing. Bulkhead frames in LH cracked and bent. In LH 20

frames cracked. Winches base corroded. Hatch coaming cracked. Bulwark frames cracked. Hull indented. Stairs corroded through. SMS maintenance failed. Shedder plates bents. Hold stairs bent.

05/12/2005 Koper

KOPER

General cargo 7035937 1639

Georgia Ladjarstvo pomorstvo Koper Koper Slovenia

Russina Maritime Register of Shipping

Detained for 3 days. 25 recorded deficiencies Steering gear room air vent corroded through. Sewage pump with rubber pipes. Drain Do pipe to transfer pipe made of rubber. Hydrophore pipes made of rubber. QCV on settling tanks inoperative. On ME No1 jacketed lines detached. On ME No 2 leaking alarm inoperative. On both MEs improper piping from leakage alarms to tanks. On compressor safety guard missing. ER overhead deck corroded through. Illegal discharge fitted over FW tank. Hoses in ER not fitted with double purpose nozzles. OWS inoperative. On OWS line illegal discharge fitted. OWS with rubber pipes. FW air pipe corroded through. ER air vent corroded through. Front bridge bulkhead FP air pipe corroded through. In paint room ventilation missing. Bilge suction pipe in paint room to short. In hold 1 three frames corroded through. In hold 1 three longitudinas corroded through. Standard discharge connection not as required. In steering gear room two illegal discharges fitted.

19/12/2005 Koper

K BURAT

General cargo 8323549

Comoros Sea Crystal Navigation Piraeus

Bulgarski Koraben Registar

Detained for 5 days. 29 recorded deficiencies FW air pipe corroded through. Both ER air vents corroded through.

5.654 Greece ER air vents dampers sized. Whistle wire torn. PS funnel damper wire torn. Deck generator fuel pipes made of rubber. DG not working in parallel. Fuel tank for deck generator not as required. Boatswain store air vent corroded through. Steering gear room air vent corroded through. STB side mess room bulkhead corroded through. FW air pipe corroded through. Chief eng. Cabin bulkhead corroded through. Boat deck corroded through. Sounding pipe of ballast tank No3 corroded through. FP air pipe corroded through. Boatswain store air vent corroded through. On FCSL bell missing. Anchor ball missing. Tank No 1 air pipe corroded through. Tank No 2 air pipe corroded through. QCV inoperative. Generator 1 and 2 not working in parallel. LO pipes for filling sump tank made of rubber. Hot well leaking. FO and DO drain pipes made of rubber. Transfer bilge piping made of rubber. Jacketed high pressure lines missing. ER bilge dirty.

21/12/2005 Koper

GINA R

General cargo 7125225 1.773

Georgia Sprante Shiffarts Brunsbuttel Germany

Bulgarski Koraben Registar

Detained for 3 days. 3 recorded deficiencies. On ME jacketed high pressure lines missing. ER fire sensors inoperative. EFP insufficient pressure.

23/12/2005 Koper

AL KARIM

General cargo 7427611 1.949

Georgia Tartous Shipping Tartous Syria

Russian Maritime Register of Shipping

Detained for 3 days. 3 recorded deficiencies. Chart not up to date. EPIRB certificate expired. ER fire sensors inoperative.

23/12/2005 Koper

BARS

Bulk carrier

Cambodia Bulcom Ltd. Sofia

Inclamar Detained for 2 days. 33 recorded deficiencies In wheelhouse 3 window

7358080 23.427

Bolgaria glasses cracked. Radio room bulkhead corroded through. Funnel corroded through. Magnetic compass with almost no liquid. Alleyway bulkhead corroded through. ER sky light corroded through. Galley air vent corroded through. Hospital bulkhead corroded through. Air condition installed without class approval. Davits frames on both lifeboats corroded through. Store window glass cracked. ER air vent corroded through. ER air vent dampers sized. Four galley windows frames corroded through. Four front bridge windows frames corroded through. Poop deck corroded through. Hatch covers on hold 7 corroded through. Both main entrance doors package holders corroded through. TS 2 tank entrance cover corroded through. Emergency fire pump entrance cover corroded through. Main fire line temporary repaired. DB2 sounding pipe holed. In steering gear room possible illegal discharge fitted. Bilge tank gauge improper. T connection pipe of doubt use fitted on sludge tank piping. Sewage pipe temporary repaired. On several FO tanks QCV inoperative. In ER several rubber pipes used for connection and transferring. Crew does not use personal protective equipment. Cylinder No 4 on DG 3 cooling water leaking. OWS inoperative. Illegal discharge fitted on OWS outboard pipe. ISM

maintenance of ship and equipment failed.

28/12/2005 Koper

RMS ARAMON

General cargo 7719480 1307

DPR Korea

Amir S.A. Shipping Delaware USA

INCLAMAR Detained for 4 days. 23 recorded deficiencies One side scuttle glass cracked. ER sky light cover corroded through. VHF DSC inoperative. PS&STB DB5 air pipes corroded through. STB BD4 air pipe corroded through. PS&STB DB 3 air pipes corroded through. STB DB2 air pipe corroded through. PS&STB DB 1 air pipes corroded through. IN FCSL two frames bent. Starting batteries for all DG in bad condition. Navigational lights alarm inoperative. DG room dirty. Hydraulic pipes for windlass leaking. On FCSL bell missing. DO filling pipe for DG made of rubber and penetrating the holed FCSL deck. QCV for DG fuel tank sized. In ER QCV on all fuel tanks inoperative. OWS inoperative. Fire alarm panel on bridge inoperative. ER air vent corroded through. ER general alarm panel malfunctioning. ME leaking tank alarm inoperative. Crew does not use personal protective equipment.