Battery-Supercapacitor Hybrid System
Design Team TenFinal Presentation
ECE 480 FS08
![Page 2: Design Team Ten Final Presentation ECE 480 FS08](https://reader036.vdocuments.mx/reader036/viewer/2022062409/56649d2d5503460f94a0403b/html5/thumbnails/2.jpg)
![Page 3: Design Team Ten Final Presentation ECE 480 FS08](https://reader036.vdocuments.mx/reader036/viewer/2022062409/56649d2d5503460f94a0403b/html5/thumbnails/3.jpg)
Evolution of the Battery/Supercapacitor Hybrid System
System 2
System 1 System 3 System 4
- 51.8 Volts
- 5 x 165F Modules
- 905 Farads Total
- 51.8 Volts
- 56 Li-Po Cells
- 4 PCMs
- 51.8 Volts
- 28 Li-Po Cells
- 2 PCMs
- 2 x 165 F Modules
- 330 Farads Total
- 51.8 Volts
- 14 Li-Po Cells
- 1 PCM
- 85 Farads Total
- 3 Solid-State Relays
- 1 Digital Relay Controller
![Page 4: Design Team Ten Final Presentation ECE 480 FS08](https://reader036.vdocuments.mx/reader036/viewer/2022062409/56649d2d5503460f94a0403b/html5/thumbnails/4.jpg)
Comparing Systems SystemSystem 2System 1 System 3 System 4
Limitations:- Excessive Weight- High Cost- Low Energy
Estimated Cost:
$9000
Limitations:- Excessive Weight- Low Power- Limited Cycle Life
Estimated Cost:
$5900
Limitations:- Relatively High Cost- Performance Limited by
Voltage Dependency
Estimated Cost:
$7400
Limitations:
- None
Estimated Cost:
$4200
![Page 5: Design Team Ten Final Presentation ECE 480 FS08](https://reader036.vdocuments.mx/reader036/viewer/2022062409/56649d2d5503460f94a0403b/html5/thumbnails/5.jpg)
Our Prototype Battery/Supercapacitor Hybrid System
![Page 6: Design Team Ten Final Presentation ECE 480 FS08](https://reader036.vdocuments.mx/reader036/viewer/2022062409/56649d2d5503460f94a0403b/html5/thumbnails/6.jpg)
Battery Components
Cells:- Rechargeable Lithium Polymer- 3.7 V Per Cell- 21 Amp/Hours
Protection Circuit Module: - Protects Cells from Overcharge & Overdischarge - Balances Voltages Between Cells- Short Circuit & Reversed Polarity Protection
![Page 7: Design Team Ten Final Presentation ECE 480 FS08](https://reader036.vdocuments.mx/reader036/viewer/2022062409/56649d2d5503460f94a0403b/html5/thumbnails/7.jpg)
Battery Specifications
- 14 Cells- 51.8 Volts- Integrated PCM
![Page 8: Design Team Ten Final Presentation ECE 480 FS08](https://reader036.vdocuments.mx/reader036/viewer/2022062409/56649d2d5503460f94a0403b/html5/thumbnails/8.jpg)
Super Capacitor Array
- 165 Farads- 48.6 Volts Nominal- Internal Monitoring Circuitry- Cell Balancing Function- High Power Density- 31 lbs
![Page 9: Design Team Ten Final Presentation ECE 480 FS08](https://reader036.vdocuments.mx/reader036/viewer/2022062409/56649d2d5503460f94a0403b/html5/thumbnails/9.jpg)
Control System
Solid-State Relays:- Remote Operated Switch- No Moving Parts- Use N-Channel MOSFETS- Rated at 40 Amps & 200
Volts
Programmable Relay Controller:- Controls Timing & Activation of the
Relays- 24 V- Controls Up To 16 Relays
![Page 10: Design Team Ten Final Presentation ECE 480 FS08](https://reader036.vdocuments.mx/reader036/viewer/2022062409/56649d2d5503460f94a0403b/html5/thumbnails/10.jpg)
System Schematic
![Page 11: Design Team Ten Final Presentation ECE 480 FS08](https://reader036.vdocuments.mx/reader036/viewer/2022062409/56649d2d5503460f94a0403b/html5/thumbnails/11.jpg)
1 Kilowatt Load Specifications
- Two 5Ω Resistors
- 1 kW Rated Each
- Connected In Parallel
- 2.5Ω Circuit
- 6’ x 9” Heatsink