MANUAL BALL VALVES
Tag Nº: BV-101 P&ID: PWT PID Line No.:
Non-Flashing Flashing Erosive Corrosive With Solids Liquid Gas Steam
1. Fluid Crude oil Service: Crude oil
Units Maximum Normal Minimum
2. Flow Rate BFPD 2,435 2,000.0 -
3. Inlet Pressure Psig 300 Psig 150 Psig 50 Psig
4. Outlet Pressure Psig 300 Psig 150 Psig 50 Psig
5. Inlet Temperature DegF 300 200 100
6. Specific Gravity 0.834 0.834 0.834
7. Viscosity cP 0.58 0.58 0.58
Specific heat ratio Cp/Cv (gamma) NA NA NA
8. bar(a) NA NA NA
Compressibility factor z 0.898 0.898 0.898
Critical pressure Pc bar(a) NA NA NA
9. Travel % NA NA NA
10. C.V. C.V. NA NA NA
11. Noise level dBA NA MA NA
13. Size-Inches & IN 3" SCH80 53. Type Manual
14. Schedule OUT 3" SCH80 54. Mfr & Model NA
15. Pipe line Insulation NONE 55. Size NA Eff Area NA
16. Type TRUNNION BALL VALVE 56. On/Off Modulating
17. FULL BORE 57. Spring Action Open Close Maintain Last Position
18. Size REFER LIST ATTACHED 58. Max Allowable Pressure NA
19. Mfr & Model Vendor to advice 59. Min Required Pressure NA
20. Body/Bonnet Matl ASTM A216 60. Available Air Supply Pressure: Max NA
21. Liner Yes No Matl 61. Min. NA
22. End. In 3" ANSI 300# RF FLANGE 62. Bench Range NA
23. Conn. Out 3" ANSI 300# RF FLANGE 63. Actuator Orientation STD Other VERTICAL STEM
24. Flg Face Finish Vendor to advice 64. Handwheel Yes No Type NA
25. End Ext. Yes No Matl 65. Air Failure Valve Yes No Set at NA
26. Flow Direction BI-DIRECTIONAL 66. Max. Diff. pressure valve should withstand NA
27. Type of Bonnet STANDARD 67. Input Signal NA
28. Lub & Iso Valve Yes No 68. Type NA
Lube 69. Mfr & Model NA
29. Packing Material VITON 70. On Incr Signal Output Incr Decr
30. Packing Type O - RING 71. Gauges By-pass
32. Type FULL BORE BALL 72. Cam Characteristic EL Conn. NA
33. Size (mm) FULL Rated Travel 90 DEG. 73. Explosion protection NA
34. Characteristic ON / OFF 74. Type Qty
35. Seats 1 2 Balanced Unbal 75. Mfr & Model
36. Rated Cv NA NA -- 76. Contacts/Rating
37. Ball Matl. SS 316 77. Actuation Points Valve open Valve Shut
38. Seat Material PTFE 78.
Soft Seat Yes No Matl 79. Mfr & Model NA
39. Cage/Guide Material NA 80. Set Pressure NA
40. Stem/Shaft Material SS 316 81. Filter Gauges NA
SPECIALS/ACCESSORIES 83. Hydro Pressure YES
43. Area classification: NA 84. ANSI/FCI Leakage Class :
Explosion proof Four Five Six (Bubble Tight)
Notes: 1 VALVES ARE TWO PIECES BOLTED BODY OF FORGED LF2 MATERIAL
2 TRUNNION MOUNTED BALL WITH SELF RELIEVING SEATS
3 FULL BORE DESIGN AND CONSTRUCTION IN ACCORDANCE WITH API 6D SPECIFICATIONS
4 FIRESAFE DESIGN TO API 607
5 BODY STUD / STUD NUTS MATERIAL: ASTM A193-B7M / A194-2HM
6 SEAT SPRING MATERIAL: INCONEL X750
DR DATE TITLE: SHT. NO.
MANUAL BALL VALVE
CHK DATE PROJECT NAME:
B For Consruction METERING SYSTEM JAVA MANIS CONT'D
A For Approval APP DATE DOC. NO. SHT. NO.
Vapor Pressure Pv
FL XT
TR
IMV
ALV
E B
OD
Y /
BO
NN
ET
LIN
ES
ER
VIC
E C
ON
DIT
ION
S
{
AC
TU
AT
OR
TE
ST
AIR
SE
TS
WIT
CH
ES
PO
SIT
ION
ER
REV DATE DESCRIPTION REV BY CHK BY
MANUAL BALL VALVESLIST OF TAG NUMBERS
QTY Tag Nº: Service Size8 HV 104 NATURAL GAS 6" ANSI RF 300#
HV 105
Notes:
DR DATE TITLE: SHT. NO.
MANUAL BALL VALVE
CHK DATE PROJECT NAME:
B For Consruction METERING SYSTEM JAVA MANIS CONT'D
A For Approval APP DATE DOC. NO. SHT. NO.
REV DATE DESCRIPTION REV BY CHK BY
MANUAL BALL VALVES
Tag Nº: HV - 101 - 102 - 103 P&ID: Line No.:
Non-Flashing Flashing Erosive Corrosive With Solids Liquid
1. Fluid NATURAL GAS Service: NATURAL GAS
Units Maximum Normal
2. Flow Rate MMSCFD 3,5 2.5
3. Inlet Pressure Psig 300 Psig 150 Psig
4. Outlet Pressure Psig 100 Psig 75 Psig
5. Inlet Temperature DegC 90 82
6. Specific Gravity 0.69498 0.69498
7. Viscosity cP 0.01251 0.01251
Specific heat ratio Cp/Cv (gamma) 1.2894 1.2894
8. bar(a) NA NA
Compressibility factor z 0.981025 0.981025
Critical pressure Pc bar(a) NA NA
9. Travel % NA NA
10. C.V. C.V. NA NA
11. Noise level dBA NA MA
13. Size-Inches & IN 3" SCH40 53. Type LEVER
14. Schedule OUT 3" SCH40 54. Mfr & Model Crane
15. Pipe line Insulation NONE 55. Size NA
16. Type TRUNNION BALL VALVE 56. On/Off Modulating
17. FULL BORE 57. Spring Action Open Close
18. Size REFER LIST ATTACHED 58. Max Allowable Pressure19. Mfr & Model KTM 59. Min Required Pressure20. Body/Bonnet Matl ASTM A105N 60. Available Air Supply Pressure:21. Liner Yes No Matl 61.
22. End. In 3" ANSI 300# RF FLANGE 62. Bench Range
23. Conn. Out 3" ANSI 300# RF FLANGE 63. Actuator Orientation STD
24. Flg Face Finish SERRATED RA 3.2 64. Handwheel Yes No
25. End Ext. Yes No Matl 65. Air Failure Valve Yes No
26. Flow Direction BI-DIRECTIONAL 66. Max. Diff. pressure valve should withstand
27. Type of Bonnet STANDARD 67. Input Signal NA
28. Lub & Iso Valve Yes No 68. Type NA
Lube 69. Mfr & Model NA
29. Packing Material VITON 70. On Incr Signal Output
30. Packing Type O - RING 71. Gauges
32. Type FULL BORE BALL 72. Cam Characteristic
33. Size (mm) FULL Rated Travel 90 DEG. 73. Explosion protection NA
34. Characteristic ON / OFF 74. Type Qty
35. Seats 1 2 Balanced Unbal 75. Mfr & Model
36. Rated Cv NA NA -- 76. Contacts/Rating
37. Ball Matl. SS 316 77. Actuation Points Valve open
38. Seat Material R - PTFE 78.
Soft Seat Yes No Matl 79. Mfr & Model NA
39. Cage/Guide Material NA 80. Set Pressure NA
40. Stem/Shaft Material SS 316 81. Filter Gauges
SPECIALS/ACCESSORIES 83. Hydro Pressure YES
43. Area classification: NA 84. ANSI/FCI Leakage Class :
Explosion proof Four Five
Vapor Pressure Pv
FL XT
TR
IMV
ALV
E B
OD
Y /
BO
NN
ET
LIN
ES
ER
VIC
E C
ON
DIT
ION
S
{
AC
TU
AT
OR
TE
ST
AIR
SE
TS
WIT
CH
ES
PO
SIT
ION
ER
Notes: 1 VALVES ARE THREE PIECES BOLTED BODY OF FORGED LF2 MATERIAL
2 TRUNNION MOUNTED BALL WITH SELF RELIEVING SEATS
3 FULL BORE DESIGN AND CONSTRUCTION IN ACCORDANCE WITH API 6D SPECIFICATIONS
4 FIRESAFE DESIGN TO API 607
5 FINAL TEST AND INSPECTION IN ACCORDANCE WITH API 6D SPECIFICATIONS
6 BODY STUD / STUD NUTS MATERIAL: ASTM A193-B7M / A194-2HM
7 SEAT SPRING MATERIAL: INCONEL X750
DR DATE TITLE:
MANUAL BALL VALVE
CHK DATE PROJECT NAME:
B For Consruction METERING SYSTEM JAVA MANIS
A For Approval APP DATE DOC. NO.
REV DATE DESCRIPTION REV BY CHK BY
MANUAL BALL VALVESLIST OF TAG NUMBERS
QTY Tag Nº: Service8 HV 101 NATURAL GAS
HV 102
HV 103
Notes:
DR DATE TITLE:
MANUAL BALL VALVE
CHK DATE PROJECT NAME:
B For Consruction METERING SYSTEM JAVA MANIS
A For Approval APP DATE DOC. NO.
REV DATE DESCRIPTION REV BY CHK BY
MANUAL BALL VALVES
Gas Steam
Normal Minimum
2.5 0.5
150 Psig 50 Psig
75 Psig 50 Psig
82 77
0.69498 0.69498
0.01251 0.01251
1.2894 1.2894
NA NA
0.981025 0.981025
NA NA
NA NA
NA NA
MA NA
LEVER
Crane
Eff Area NA
Maintain Last Position
NA
NA
Max NA
Min. NA
NA
Other VERTICAL STEM
Type NA
Set at NA
NA
NA
NA
NA
Incr Decr
By-pass
EL Conn. NA
NA
Valve Shut
NA
NA
Gauges NA
YES
Six (Bubble Tight)
VALVES ARE THREE PIECES BOLTED BODY OF FORGED LF2 MATERIAL
TRUNNION MOUNTED BALL WITH SELF RELIEVING SEATS
FULL BORE DESIGN AND CONSTRUCTION IN ACCORDANCE WITH API 6D SPECIFICATIONS
FIRESAFE DESIGN TO API 607
FINAL TEST AND INSPECTION IN ACCORDANCE WITH API 6D SPECIFICATIONS
BODY STUD / STUD NUTS MATERIAL: ASTM A193-B7M / A194-2HM
SEAT SPRING MATERIAL: INCONEL X750
SHT. NO.
MANUAL BALL VALVE
METERING SYSTEM JAVA MANIS CONT'D
SHT. NO.
MANUAL BALL VALVESLIST OF TAG NUMBERS
Size3" ANSI RF 300#
SHT. NO.
MANUAL BALL VALVE
METERING SYSTEM JAVA MANIS CONT'D
SHT. NO.
MANUAL BALL VALVES
Tag Nº: HV - 106 - 107 P&ID: Line No.:
Non-Flashing Flashing Erosive Corrosive With Solids Liquid
1. Fluid NATURAL GAS Service: NATURAL GAS
Units Maximum Normal
2. Flow Rate MMSCFD 3,5 2.5
3. Inlet Pressure Psig 300 Psig 150 Psig
4. Outlet Pressure Psig 100 Psig 75 Psig
5. Inlet Temperature DegC 90 82
6. Specific Gravity 0.69498 0.69498
7. Viscosity cP 0.01251 0.01251
Specific heat ratio Cp/Cv (gamma) 1.2894 1.2894
8. bar(a) NA NA
Compressibility factor z 0.981025 0.981025
Critical pressure Pc bar(a) NA NA
9. Travel % NA NA
10. C.V. C.V. NA NA
11. Noise level dBA NA MA
13. Size-Inches & IN 4" SCH40 53. Type LEVER
14. Schedule OUT 4" SCH40 54. Mfr & Model Crane
15. Pipe line Insulation NONE 55. Size NA
16. Type TRUNNION BALL VALVE 56. On/Off Modulating
17. FULL BORE 57. Spring Action Open Close
18. Size REFER LIST ATTACHED 58. Max Allowable Pressure19. Mfr & Model KTM 59. Min Required Pressure20. Body/Bonnet Matl ASTM A105N 60. Available Air Supply Pressure:21. Liner Yes No Matl 61.
22. End. In 4" ANSI 300# RF FLANGE 62. Bench Range
23. Conn. Out 4" ANSI 300# RF FLANGE 63. Actuator Orientation STD
24. Flg Face Finish SERRATED RA 3.2 64. Handwheel Yes No
25. End Ext. Yes No Matl 65. Air Failure Valve Yes No
26. Flow Direction BI-DIRECTIONAL 66. Max. Diff. pressure valve should withstand
27. Type of Bonnet STANDARD 67. Input Signal NA
28. Lub & Iso Valve Yes No 68. Type NA
Lube 69. Mfr & Model NA
29. Packing Material VITON 70. On Incr Signal Output
30. Packing Type O - RING 71. Gauges
32. Type FULL BORE BALL 72. Cam Characteristic
33. Size (mm) FULL Rated Travel 90 DEG. 73. Explosion protection NA
34. Characteristic ON / OFF 74. Type Qty
35. Seats 1 2 Balanced Unbal 75. Mfr & Model
36. Rated Cv NA NA -- 76. Contacts/Rating
37. Ball Matl. SS 316 77. Actuation Points Valve open
38. Seat Material R - PTFE 78.
Soft Seat Yes No Matl 79. Mfr & Model NA
39. Cage/Guide Material NA 80. Set Pressure NA
40. Stem/Shaft Material SS 316 81. Filter Gauges
SPECIALS/ACCESSORIES 83. Hydro Pressure YES
43. Area classification: NA 84. ANSI/FCI Leakage Class :
Explosion proof Four Five
Vapor Pressure Pv
FL XT
TR
IMV
ALV
E B
OD
Y /
BO
NN
ET
LIN
ES
ER
VIC
E C
ON
DIT
ION
S
{
AC
TU
AT
OR
TE
ST
AIR
SE
TS
WIT
CH
ES
PO
SIT
ION
ER
Notes: 1 VALVES ARE THREE PIECES BOLTED BODY OF FORGED LF2 MATERIAL
2 TRUNNION MOUNTED BALL WITH SELF RELIEVING SEATS
3 FULL BORE DESIGN AND CONSTRUCTION IN ACCORDANCE WITH API 6D SPECIFICATIONS
4 FIRESAFE DESIGN TO API 607
5 FINAL TEST AND INSPECTION IN ACCORDANCE WITH API 6D SPECIFICATIONS
6 BODY STUD / STUD NUTS MATERIAL: ASTM A193-B7M / A194-2HM
7 SEAT SPRING MATERIAL: INCONEL X750
DR DATE TITLE:
MANUAL BALL VALVE
CHK DATE PROJECT NAME:
B For Consruction METERING SYSTEM JAVA MANIS
A For Approval APP DATE DOC. NO.
REV DATE DESCRIPTION REV BY CHK BY
MANUAL BALL VALVESLIST OF TAG NUMBERS
QTY Tag Nº: Service8 HV 106 NATURAL GAS
HV 107
Notes:
DR DATE TITLE:
MANUAL BALL VALVE
CHK DATE PROJECT NAME:
B For Consruction METERING SYSTEM JAVA MANIS
A For Approval APP DATE DOC. NO.
REV DATE DESCRIPTION REV BY CHK BY
MANUAL BALL VALVES
Gas Steam
Normal Minimum
2.5 0.5
150 Psig 50 Psig
75 Psig 50 Psig
82 77
0.69498 0.69498
0.01251 0.01251
1.2894 1.2894
NA NA
0.981025 0.981025
NA NA
NA NA
NA NA
MA NA
LEVER
Crane
Eff Area NA
Maintain Last Position
NA
NA
Max NA
Min. NA
NA
Other VERTICAL STEM
Type NA
Set at NA
NA
NA
NA
NA
Incr Decr
By-pass
EL Conn. NA
NA
Valve Shut
NA
NA
Gauges NA
YES
Six (Bubble Tight)
VALVES ARE THREE PIECES BOLTED BODY OF FORGED LF2 MATERIAL
TRUNNION MOUNTED BALL WITH SELF RELIEVING SEATS
FULL BORE DESIGN AND CONSTRUCTION IN ACCORDANCE WITH API 6D SPECIFICATIONS
FIRESAFE DESIGN TO API 607
FINAL TEST AND INSPECTION IN ACCORDANCE WITH API 6D SPECIFICATIONS
BODY STUD / STUD NUTS MATERIAL: ASTM A193-B7M / A194-2HM
SEAT SPRING MATERIAL: INCONEL X750
SHT. NO.
MANUAL BALL VALVE
METERING SYSTEM JAVA MANIS CONT'D
SHT. NO.
MANUAL BALL VALVESLIST OF TAG NUMBERS
Size4" ANSI RF 300#
SHT. NO.
MANUAL BALL VALVE
METERING SYSTEM JAVA MANIS CONT'D
SHT. NO.
BAK SEPTIC TANK
Dimensi Bak Septic Tank
Jumlah = 1 unit #VALUE! #VALUE! hariVolume = #VALUE! m3 40.5Panjang = 9.00 mLebar = 4.50 mTinggi = 3.70 mFree board 0.30 m
Unit tambahan untuk proses di Bak Septic Tank
Pompa tran*Jumlah 2 unit*Jenis Submersible pump*Kapasitas/ 15 liter/min #VALUE!*Head 6 m Aqua
BAK ANAEROBIC
Dimensi Bak Anaerobic
Jumlah = 2 unitVolume = 104.77 m3 55 #VALUE! hari Panjang = 7.4 m 37.4Lebar = 2.4 m 17.8Tinggi = 2.8 mFree board 0.7 m
Unit tambahan untuk proses di Bak Anaerob
Packing *Jumlah*Jenis Batu split*Ukuran 40 mm x 80 mm
SAND FILTER
Jumlah = 2 unitVolume = 50.97 m3 67.07 66.89Panjang = 11.60 m 67.28 #VALUE! hariLebar = 5.80 mTinggi = 0.76 m
Silica sand*Jumlah 63713 kg*Ukuran
*Jumlah 2 unit*Jenis Submersible pump*Kapasitas 15 liter/min*Head 18 m Aqua
No. Prosp : General D : Limbah c 15.12 m3/hariDate :
BAK SEPTIC TANK
Dimensi Bak Septic Tank
Jumlah = 1 unit 40.9 10 hariVolume = 151.20 m3 40.5Panjang = 9.00 mLebar = 4.50 mTinggi = 3.70 mFree board 0.30 m
Unit tambahan untuk proses di Bak Septic Tank
Pompa tran*Jumlah 2 unit*Jenis Submersible pump*Kapasitas/ 15 liter/min 11*Head 6 m Aqua
BAK ANAEROBIC
Dimensi Bak Anaerobic
Jumlah = 2 unitVolume = 104.77 m3 55 6.93 hari Panjang = 7.4 m 37.4Lebar = 2.4 m 17.8Tinggi = 2.8 mFree board 0.7 m
Unit tambahan untuk proses di Bak Anaerob
Packing *Jumlah*Jenis Batu split*Ukuran 40 mm x 80 mm
SAND FILTER
Jumlah = 2 unitVolume = 50.97 m3 67.07 66.89Panjang = 11.60 m 67.28 3.37 hariLebar = 5.80 mTinggi = 0.76 m
Silica sand*Jumlah 63713 kg*Ukuran
*Jumlah 2 unit*Jenis Submersible pump*Kapasitas 15 liter/min*Head 18 m Aqua