deploying and managing new cell sites with ftta · cable & antenna analysis rf-in sfp port 2...

21
Telecom Infra Event March 2015 Ulrich Müller [email protected] Deploying and managing new cell sites with FTTA - RFoFiber Interference Test

Upload: others

Post on 27-Mar-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

Telecom Infra Event March 2015

Ulrich Müller

[email protected]

Deploying and managing new

cell sites with FTTA- RFoFiber Interference Test

Page 2: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 2

Introduction to Distributed Cell Sites

RFoCPRITM Technology Overview

Topics

Page 3: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 3

Radio

Coaxial

Feeder

Antennas

Base Band Unit

BBU

Fiber

Feeder

(CPRI)

Antennas

Remote

Radio Head

RRH

BackhaulBackhaul

Distributed Cell SitesIntroduction to Distributed Cell Sites (CPRI/Fiber)

Conventional Cell Site Distributed Cell Site

Cell Sites with coaxial

feeders:

Advantages: + RF access from the radio

for interference analysis

and conformance testing

Disadvantages:- High Loss

- Signal Reflections

- Passive Intermodulation

(PIM)

Cell Sites with fiber

feeders:

Advantages: + Minimal signal loss

+ Minimal signal reflections

+ Minimal passive

intermodulation (PIM)

Disadvantages:- RF access from the RRH

Page 4: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 4

Distributed Cell SiteInterference Analysis

RF access at Remote Radio Heads

Long Resolution Time (Tower Climb)

High Maintenance Cost

Safety Concerns

Spectrum Analysis

Remote Radio Head

Page 5: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 5

CPRI Topology Scenarios

Distributed Cell SitesTopologies

Chain

Tree

RRU

BBU Bank

𝐶𝑃𝑅𝐼

𝐹𝑖𝑏𝑒𝑟

RRURRU

RRU

RRU RRU

C-Ran

RRU

RRU

RRU

RRU RRU RRU

RRU RRU

BBU Bank

𝐶𝑃𝑅𝐼

𝐹𝑖𝑏𝑒𝑟

DAS

Span

Page 6: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 6

Introduction to Distributed Cell Sites

RFoCPRITM Technology Overview

Topics

Page 7: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 7

CPRI is an industry cooperation defining a specification for the interface between the Radio Equipment Control (REC) or BBU and the Radio Equipment (RE) or RRU.

• Three different information flows (User Plane data, Control and Management Plane data, and Synchronization Plane data) are multiplexed over the interface.

CPRI Technology OverviewInformation Flows

Control and Management Plane: The control data flow used for call processing and management data is for the operation, administration and maintenance of the CPRI link and its nodes.

Synchronization Plane: Data flow which transfers frame and time alignment information between nodes.

User Plane: user plane data is transported in the form of IQ data flows which reflects the data of one antenna for one carrier, the so-called antenna-carrier (AxC).

Radio Equipment Control

(REC)

Radio Equipment

(RE)

LAYER 2

LAYER 1

LAYER 2

LAYER 1

CPRICTRL & MGMT

PLANE

SYNC

PLANE

USER

PLANE

CTRL & MGMT

PLANE

SYNC

PLANE

USER

PLANE

BackhaulAntennas

BBU RRU

Backhaul

Page 8: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 8

BBU

Channel coding, interleaving and

modulation.

MIMO processing.

Tx power control.

Slot and frame generation.

RRU

Digital/Analog conversion.

Frequency up-conversion.

Carrier multiplexing.

Power amplification.

RF filtering.

LTE Downlink Signal Processing

CPRI Technology OverviewLTE Downlink Signal Processing of BBU and RRU

Power

Frequency0 Hz

Power

Frequency751 MHz

AmplificationFiltering

CPRI

Page 9: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 9

RRU

Frequency down-conversion.

Automatic gain control.

Carrier de-multiplexing.

RF filtering.

Analog/Digital conversion.

BBU

Channel decoding, de-

interleaving, demodulation.

MIMO processing.

Transmit power control.

Signal distribution for processing.

LTE Uplink Signal Processing

CPRI Technology OverviewLTE Uplink Signal Processing of BBU and RRU

Power

Frequency782 MHz

Power

Frequency0 Hz

Amplification Filtering

CPRI

Page 10: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 10

RFoCPRI Technology OverviewArchitecture

SFP-A

SFP-BEthernet

Cable &

Antenna

Analysis

RF-InSFP

Port 2 SFP

Port-1

RFoCPRITM Option Board

I/O Interface

ClientHost

DC 12–19V

Cable and Antenna Analyzer

+25dBm MAX, 50VDC MAX

RF In 50Ω

Spectrum Analyzer

Reflection /

RF Out 50ΩRF In 50Ω

USB

LAN Port 2

+25dBm MAX

50VDC MAX

GPS Trigger Ref

External In10/100/1000 Port 1

Cable & Antenna

Analysis

Amplifier/Filter

Insertion G/L

GPS Positioning

Sync & Timing

Fiber Inspection

I/O Interface

RFoCPRI

Page 11: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 11

Optical power level > -20dBm

RFoCPRI Technology Optical Power and Fiber Inspection

Page 12: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 12

RFoCPRI TechnologyCPRI Monitoring

BBUBBU

α β γ

α β γ

(Sectors)

(Sectors)

Optical Coupler

α β γ (Sectors)

Coupled

CPRI link

RFoCPRITM

Standard Cell Site Deployment Cell Site with CPRI Monitoring

Page 13: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 13

RFoCPRI Technology OverviewFiber Connection

In Service

ClientHost

18 VDC

Cable and Antenna Analyzer

+25dBm MAX, 50VDC MAX

RF In 50Ω

Spectrum Analyzer

Reflection /

RF Out 50ΩRF In 50Ω

Port 2

SFP/SFP+

+25dBm MAX

50VDC MAX

GPS Trigger Ref

External In

10/100/1000

Port 1

SFP/SFP+

RXTXRE

TXRXREC UL

CouplingDL

Coupling

Three-Channel Optical nTAP

Out of Service

ClientHost

18 VDC

Cable and Antenna Analyzer

+25dBm MAX, 50VDC MAX

RF In 50Ω

Spectrum Analyzer

Reflection /

RF Out 50ΩRF In 50Ω

Port 2

SFP/SFP+

+25dBm MAX

50VDC MAX

GPS Trigger Ref

External In

10/100/1000

Port 1

SFP/SFP+

RXTXRRH

TX RX

Three-Channel Optical nTAP

Page 14: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 14

RFoCPRITM Spectrum Analysis LTE Uplink 10 MHz

Spectrogram Spectrum Replay

RFoCPRI Technology OverviewLTE Uplink Signal Processing of BBU and RRU

Page 15: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 15

RfoCPRI Technology Overview

RFoCPRITM Spectrum Analysis LTE Uplink 10 MHz

Spectrogram Spectrum Replay

Page 16: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 16

RFoCPRI Technology Overview

Dual Spectrum Measurement screen

• Monitor Antenna0 and Antenna1 simultaneously.

* Two spectrum should be in the same CPRI link

Page 17: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 17

RFoCPRI Technology Overview

Dual Spectrogram Measurement screen

• Monitor Ant0 and Ant1 (MIMO) simultaneously.

* Two spectrum should be in the same CPRI link

Page 18: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 18

RFoCPRI Technology Overview

RF Source with RFoCPRI

Mode

RFoFiber

RFoCPRI

RFoOBSAI

Layer 2 Monitoring

Layer 2 Term

Interference Analyzer

PIM Detection

Measure

Spectrum

Spectrogram

RSSI

Spectrum Replayer

Fronthaul

RF/Coaxial

RRH

IQ Spectrum

CW Signal Injection

Application• Uplink noise floor calibration at a given point• Uplink gain / dynamic range check• AxC configuration checkMeasurement modes that

support RF source function

Page 19: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 19

RFoCPRI Technology OverviewUplink PIM Detection

CellAdvisor JD785B

RFoCPRI

Copper

Fiber

Optical

Splitter

FIBER RX

Uplink Spectrogram

RRU

BBU

Phase Line Rate

Mbps

Word Size

bits

CPRI

Frames

1228.8 16 2

2457.6 32 4

3072.0 40 5

4915.2 64 8

6144.0 80 10

9830.4 128 16

IQ UPLINK DEMAPPER

ELECTRICAL

IQ

VE

ND

OR

ET

H

TDM

HD

LC

L1

Inband

USER

PLANE

CONTROL

PLANESYNC

OPTICAL

Page 20: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

© 2014 JDS Uniphase Corporation | JDSU CONFIDENTIAL AND PROPRIETARY INFORMATION 20

RFoCPRI Technology OverviewPassive Intermodulation

Spectrum (Ant. 1 & 2) Spectrogram (Ant.1)

Page 21: Deploying and managing new cell sites with FTTA · Cable & Antenna Analysis RF-In SFP Port 2 SFP Port-1 RFoCPRITM Option Board I/O Interface Host Client DC 12² 19V Cable and Ant

Thank you!More info at:

Fomax Test & Connectivity B.V.

Versterkerstraat 3b

1322 AN Almere

036-7601023

06-55894451

[email protected]:1. Common Public Radio Interface (CPRI); Interface

Specification V6.

2. Remote Radio Unit Description by Ericsson.

3. JDSU CellAdvisor JD785B.