delta ups product overview - energysa peruenergysaperu.com/pdf/ups/delta/presentacion - delta... ·...
TRANSCRIPT
1
Delta UPS Product Overview
15-Jun-12
2
Product Application Matrix
Agilon Amplon
Hestia - 0.6 kVA
(line interactive) VX- 0,6 kVA
(line interactive)
RT Series
5-10 kVA
(online)
N Series
1-3 kVA
(online)
N Series
6, 12 kVA
(online)
GAIA Series
1-3 kVA
(online)
GAIA Series
5-11kVA
(online)
R Series
1-3 kVA
(online)
Configuration 1:1 X X X X X X X X
Configuration 3:1
Configuration 3:3
Rack mountable X X X X
Stand alone X X X X X X X X
Isolation Transformer X
Backup ’ S S S,L S,L S,L S S,L S,L
Home and office * X X X X
Small enterprise, IT and medical
** X X X X X X
Medium enterprice, telecom, IT,
media *** X X X
Heavy i ndustry, telecom, IT,
defence, industry and building
automation ****
’ Small back up time is 5~30mins.----- Long back up time is 0.5~24hrs
* PCs, laptops, modems, printers, hifi and audio equipment
** Computers, servers, networking, medical control and diagnostics, education, banking, info kiosks, industrial automation
*** telecom base stations, , data centers, backbone networks, broadcasting, projection systems
**** telecom centers, data centers, medical equipment at hospitals, government use, automatic control, oil, gas and power utilities, industrial
equipment, automation and control
3
Product Application Matrix
Ultron Modulon
H Series
15-30kVA
(online)
NT Series
20-500kVA
(online)
DPS Series
160-1600kVA
(online)
NH Series
20-80kVA
(online)
NH Plus Series
20-120kVA
(online)
Configuration 1:1
Configuration 3:1 X X
Configuration 3:3 X X X X X
Rack mountable
Stand alone X X X X X
Isolation Transformer X
Backup ’ S,L S,L S,L S,L S,L
Home and office *
Small enterprise, IT and medical **
Medium enterprice, telecom, IT, media *** X X X X
Heavy i ndustry, telecom, IT, defence,
industry and building automation **** X X X X X
’ Small back up time is 5~30mins.----- Long back up time is 0.5~24hrs
* PCs, laptops, modems, printers, hifi and audio equipment
** Computers, servers, networking, medical control and diagnostics, education, banking, info kiosks, industrial automation
*** telecom base stations, , data centers, backbone networks, broadcasting, projection systems
**** telecom centers, data centers, medical equipment at hospitals, government use, automatic control, oil, gas and power utilities, industrial
equipment, automation and control
4
Delta UPS Product Overview
• Delta UPS fall in four categories according to power level:
– : Data Center, Facility & Industrial
• H Series 15-30 kVA (3-phase, on-line)
• NT Series 20-500 kVA (3-phase, on-line)
• DPS Series 160-1600kVA (3-phase, on-line)
– : PC & Peripherals
• Hestia 600 VA (1-phase, line-interactive)
• VX 600 VA (1-phase, line-interactive)
– : Server & Networking
• GAIA Series 1-3 kVA (1-phase, on-line)
• N Series 1-3 kVA (1-phase, on-line)
• N Series 6-12 kVA (1-phase, on-line)
• R Series 1-3 kVA (1-phase, on-line)
• RT Series 5-10 kVA (1-phase, on-line)
– : Modular
• NH Series 20-80 kVA (3-phase, on-line)
• NH Plus Series 20-120 kVA (3-phase, on-line)
5
• True on-line double conversion technology.
• Wide input voltage range.
• High input power factor and low iTHD.
• Compact dimension.
• Smart cards available for customize capability.
• Delta’s powerful monitoring software for easy
UPS remote management.
• Available for long backup application.
Applications
– Offices
– Networking
– Medical
– Banking
– Security
Delta Single Phase UPS
6
• True on-line double conversion technology.
• Wide input range.
• High efficiency.
• High input power factor and low iTHD.
• Delta’s powerful monitoring software for easy UPS
remote management.
• Multi-Language user-friendly graphic LCD display
and LED indicators.
• Parallel redundancy installation for reliability
enhancement.
• Parallel expansion for flexibility and initial
investment savings.
• Modular design for easy commissioning.
Applications
– Networking
– Data Center
– Telecommunication
– Medical
– Banking
– Industry
Delta Three Phase UPS
7
Delta UPS - Up to 12 kVA on-line UPS
GAIA Series 1-3 kVA (on-line)
N Series 1-3 kVA (on-line)
N Series 6-12 kVA (on-line)
R Series 1-3kVA (on-line)
RT Series 5-10kVA (on-line)
8
• Standard 19 inches rack / tower configuration(2U).
• Reduced battery discharge probability – extended
battery lifetime.
• RS232 and USB connectivity with Vista
compatible power management software.
• Built-in data line surge protector for phone / fax /
network.
• Output receptacles programmable for efficient
energy usage.
• Smart slot for mission critical applications.
• Extended battery cabinet available. Applications
– Server Rack
– ATM
– Security
– Audio/Video
GAIA Series 1-3kVA
9
1 kVA / 0.8kW 2 kVA / 1.6 kW 3 kVA / 2.1kW
Model GA1000R GA2000R GA3000R
Voltage 200 / 208 / 220 / 230 / 240Vac, single phase
Input Voltage Range 160 ~ 275 (full load)130 ~ 160 (linearly de-rating between 70% ~ 100% loading)
Input Connection Power cord
Output Receptacle IEC320 C13 x 3 x2 IEC320 C13 x 3 x 2; IEC320 C19 x 1
Internal Battery 12V/9Ah x 2 12V/9Ah x 4 12V/9Ah x 6
Backup Time > 12 minutes (half load)
> 4 minutes (full load)
> 14 minutes (half load)
> 5 minutes (full load)
> 15 minutes (half load)
> 5 minutes (full load)
EBC* Model GA1000RB GA2000RB GA3000RB
EBC Rating 9Ah x 2 x 2 9Ah x 4 x 2 9Ah x 6 x 2
Interface RS232 x 1, USB x 1, SNMP slot x 1
Data Line Surge Protector Built-in (RJ11/RJ45, 1-to-1)
Tower Stand Kit Included
Rack Rail Kit Optional
Extended Battery Cabinet Optional. The connection cable to UPS is attached.
Connector is non-standard type.
WxDxH (mm), same for UPS
and EBC 440x335x89 440x432x89 440x610x89
UPS Weight (kg) 13 21 31
Battery Cabinet (kg) 16 29 43
* EBC : Extended Battery Cabinet.
GAIA Series 1-3kVA Spec.
10
• Reduced battery discharge probability –
extended battery lifetime.
• Compact size. Savings in the installation space.
• Smart slot for mission critical applications.
• RS232 connectivity with Vista compatible power
management software.
• Long backup model available.
• Extended battery cabinet available.
Applications
– PC, Workstation
– POS
– ATM
– Security
N Series 1-3kVA
11
1 kVA / 0.7kW 2 kVA / 1.4 kW 3 kVA / 2.1kW
Model GES102N200035 GES202N200035 GES302N200035
Voltage 200 / 208 / 220 / 230 / 240Vac, single phase
Input Voltage Range 80~280Vac. Lower range 80~176Vac is acceptable under 50~100% loading condition.
Input Connection Power cord
Output Receptacle IEC320 C13 x 4 IEC320 C13 x 8
Internal Battery 12V/7Ah x 3 12V/7Ah x 6 12V/9Ah x 6
Backup Time > 14 minutes (half load)
> 5 minutes (full load)
EBC* Rating 12V/7Ah x 6 12V/9Ah x 6
Interface RS232x1 RS232x1, SNMP slot x 1
Data Line Surge Protector Optional (RJ11/RJ45, 1-to-1)
Extended Battery Cabinet Optional. Connection is by Delta standard battery cable.
UPS WxDxH (mm) 140x366x242 140x425x373
EBC WxDxH (mm) 140x366x242 (Same as 1KVA)
UPS Weight (kg) 14 30.5
EBC Weight (kg) 20
* EBC : Extended Battery Cabinet.
N Series 1-3kVA Specification *Version 120Vac
12
• Reduced battery discharge probability – extended
battery lifetime.
• High input power factor(pf>0.98), savings in
installation costs.
• Built-in isolation transformer and dual output voltage.
• Built-in manual bypass switch for maintenance.
• High recharging capability: Up to 8Amp with optional
extra charger.
• Remote emergency power off function.
• Extended battery cabinet available.
Applications
– IT Room
– Medium Office
– Banking
N Series 6,12kVA
13
6 kVA / 4.2kW 12 kVA / 8.4kW
Model GES602N500135 GES123N500135
Voltage 120/220Vac , single phase
Input Voltage Range 120~280Vac. Lower range 120~176Vac is acceptable under 70~100% loading condition.
Input/Output Connection Hard wire (Terminal block)
Internal Battery 12V/7Ah x 20 12V/7Ah x 20
EBC* Rating 12V/7Ah or 9Ah, maximum 60pcs
Battery Charging 0.7A 1.3A
Optional Charger Board Max. 7A (external installation)
Internal Battery None! Customer can connect to their own battery source based on correct rating.
Interface RS232x1, SNMP slotx1, Dry contatx1
Maintenance Bypass
Switch Built-in
UPS WxDxH (mm) 280x581x784
EBC WxDxH (mm) 280x581x784
UPS Weight (kg) 133 165
EBC Weight (kg)
* EBC : Extended Battery Cabinet.
N Series 6,12kVA Spec.
14
• Standard 19 inches rack / tower configuration(2U).
• Reduced battery discharge probability – extended
battery lifetime.
• Battery independent function to fulfill backup time
by customized battery source. Specially for long
backup application.
• High recharging capability: built-in 4.5-5Amp and
optional 4.5-5Amp extra charger.
• Smart slot for mission critical applications.
• RS232 connectivity with Vista compatible power
management software.
• Extended battery cabinet available(Only for 1kVA
model).
Applications
– Server Rack
– ATM
– Security
– Long Backup
Time
R Series 1-3kVA
15
1 kVA / 0.7kW 2 kVA / 1.4 kW 3 kVA / 2.1kW
Model GES102R202035 GES202R202035 GES302R202035
Voltage 230Vac , single phase
Input Voltage Range 80~280Vac. Lower range 80~176Vac is acceptable under 50~100% loading condition.
Input Connection Power cord
Output Receptacle IEC C13x4 IEC C13x8 ; IEC C19x1
Battery Source Rating 36Vdc 72Vdc
Battery Charging Max. 5A Max. 4.5A
Optional Charger Board* Max. 5A Max. 4.5A
Internal Battery None! Customer can connect to their own battery source based on correct rating.
Interface RS232x1, SNMP slotx1
Tower Stand Kit Optional
Rack Rail Kit Included
Data Line Surge Protector Optional
EBC** Optional. Connection is by Delta standard battery cable.
WxDxH (mm) 440x450x89
Weight (kg) 6.7 9.2
* Extra charger board is installed inside UPS.
** EBC : Extended Battery Cabinet.
R Series 1-3kVA Specification *Version 120Vac
16
• Standard 19 inches rack / tower configuration.
• High output power factor 0.9
• 1+1 parallel redundancy to increase the reliability
and flexibility.
• High input power factor (pf > 0.99) and low
harmonic distortion (iTHD < 5%).
• High recharging capability: built-in 4Amp and
optional 4Amp extra charger.
• Two smart slots for mission critical applications.
• Multi-language LCD display and status LED.
• Optional maintenance bypass box for parallel
redundancy with manual bypass switch.
• Extended battery cabinet available.
• Extended charger box available.
Applications
– IT Room
– Security
– Banking
– Long Backup Time
RT Series 5-10kVA
17
5 kVA / 4.5kW 6 kVA / 5.4 kW 10 kVA / 9kW
Model RT5K RT6K RT10K
Voltage 200/208/220/230/240Vac , single phase
Input Voltage Range 100~300Vac
Input/Output Connection Hard wire (Terminal block)
EBC* Rating 12V/5Ah x 16 12V/9Ah or 12V/34W x 20
Battery Charging Max. 4A
Optional Charger Board** Max. 4A
Internal Battery None! Customer can connect to their own battery source based on correct rating.
Interface RS232x1, SNMP slotx1, Smart slotx1
Rack Rail Kit Optional (But tower stand kit is included)
Parallel Redundancy 1+1
Maintenance Bypass Box Optional
UPS WxDxH (mm) 440x671x89 440x623x131
EBC WxDxH (mm) 440x638x89 440x595x131
UPS Weight (kg) 15.5 21.3
EBC Weight (kg) 37 66
* EBC : Extended Battery Cabinet.
** Extra charger board is installed inside UPS.
RT Series 5-10kVA Spec.
18
Delta UPS - Up to 4000 kVA online UPS
H Series 15-30 kVA (on-line)
NT Series 20-500 kVA (on-line)
DPS Series 160-1600kVA (on-line)
19
• Reduced battery discharge probability – extended
battery lifetime.
• High input power factor, savings in installation costs.
• Hot-standby installation is feasible to increase the
reliability.
• Built-in manual bypass switch for maintenance.
• Extended battery cabinet available.
• Local and remote emergency power off function.
Applications
– Small Data Center
– Banking
– IT Room
H Series 15-30kVA
20
15 kVA / 12kW 20 kVA / 16 kW 30 kVA / 24 kW
Model GES153H GES203H GES303H
Voltage 220/380 , 230/400 , 240/415 (3phase, 4-wire plus ground)
Input Voltage Range 156 ~ 280 / 270 ~ 485 Vac
Input/Output Connection Hard wire (Terminal block)
Output Voltage 3/3 model : 220/380 , 230/400 , 240/415 (3phase)
3/1 model : 220/230/240 (single phase)
220/380 , 230/400 , 240/415
(3phase)
Battery Source Rating 240Vdc
Battery Charging 2.6A 5.2A
Optional Charger Board Max. 5A (external installation)
Internal Battery None
Interface RS232x1, SNMP slotx1, AS400x1, Dry contactx1
Maintenance Bypass Switch Built-in
EBC* Optional (Two type : 26Ah or 40Ah)
Connection is by Delta standard battery cable.
WxDxH (mm) 380x650x860 (UPS and EBC are the same)
UPS Weight (kg) 108
EBC Weight (kg) 26Ah: 270kg ; 40Ah: 370kg
* EBC : Extended Battery Cabinet.
H Series 15-30kVA Spec. *Version 120Vac (20kva y 30kva)
21
• N+X parallel reduncancy (up to 8 cabinets) for reliability
and flexibility, w/o extra hardware.
• Economic mode for energy and operation cost savings.
• Built-in manual bypass switch for maintenance.
• Built-in SRAM, recording maximum 500 real-time event
logs.
• Compatible with gnerator installation.
• 6 configurable UPS status dry contact outputs.
• Optional 12-pulse rectifier or filter for lower harmonic
distortion.
• Possibility for shared battery source enabling cost savings.
• Custom order voltage rating.
• Extended battery cabinet available.
Applications
– Networking
– Data centers
– Telecommunications
– Medical
– Banking
– Industrial
NT Series 20-500kVA
22
100-120 kVA 20-80 kVA 160-200 kVA
260-400 kVA 500 kVA
NT Series Product Family
23
20
kVA
30
kVA
40
kVA
50
kVA
60
kVA
80
kVA
100
kVA
120
kVA
160
kVA
200
kVA
260
kVA
320
kVA
400
kVA
500
kVA
W x D x
H (m) 0.6 x 0.8 x 1.4
0.8 x 0.83 x
1.7 1.2 x 0.83 x 1.7 1.6 x 0.995 x 1.95
1.9 x
0.995 x
1.95
Weight
(kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2400
NT-series general specification
Voltage 120 / 208, 220 / 380, 230 / 400, 240 / 415, 277 / 480Vac,
three phase, 4 wire plus ground
Voltage Range ±20 %
Interface RS232 x 1, RS485 x 1, SNMP slot x 1, Status output x 6
Parallel Redundancy Maximum 8 units
Input Harmonic Improvement Optional 12-Pulse rectifier or filter
SRAM Event Log Maximum 500 records
Battery Start Yes
* Above table is based on 220/380Vac rating.
** 500KVA model is assembled by two cabinets: Inverter (width=1100mm, 1700kg) and Rectifier (width=800mm, 700kg).
NT Series Specification
24
• Rating: 160/200kVA, double conversion 3phase UPS
• 0.9 high output power factor delivers more real power
• IGBT-based rectifier and transformer-less architecture
• Novel 3 Phase PFC Topology (3 Phase 4 Switch)
• Three-Level Inverter Topology
• Energy efficiency up to 95% (on-line mode)
• Fully digital control guarantees higher reliability
• Wide Input voltage range (-40% ~ 20%)
• Parallel link up to 8 units
• Mimic LCD display with multi-language selection
• Front access for easy maintenance
• Compact design
DPS Series 160 – 200kVA
25
DPS Series 160 – 200kVA
26
Delta UPS - Up to 480 kVA online UPS
NH Series 20-80 kVA (on-line)
NH Plus Series 20-120 kVA (on-line)
27
• N+X parallel reduncancy (up to 4 cabinets, total max.
=320kVA) for reliability and flexibility, w/o extra
hardware.
• High input power factor (pf > 0.99) and low harmonic
distortion (iTHD < 3%).
• Over 94 % high efficiency.
• Modular design for easy maintenance.
• Built-in manual and static bypass switch for
maintenance.
• Built-in SRAM, recording maximum 500 real-time
event logs.
• Multi-language LCD display and status LED
indicators.
• Compatible with gnerator installation.
• 6 configurable UPS status dry contact outputs.
• Optional kit for monitoring battery cabinet
temperature.
• Customized voltage rating.
Applications
– Networking
– Data centers
– Telecommunications
– Medical
– Banking
– Industrial
NH Series 20-80kVA
28
20KVA 40KVA 60KVA 80KVA
Modular design enables:
•Easy expansion of the system
•Easy spare parts management
•Easy maintainability in the field
NH Series Modular UPS
29
Battery
Cabinet UPS
Battery
Cabinet UPS
Custom Order Type
I/P & O/P : Custom order voltage
Capacity : 20/40/60/80kVA
Standard Type
I/P & O/P : 380/220V
Capacity : 20/40/60/80kVA
NH Series – Available Type
30
20 kVA / 16 kW 40kVA / 32kW 60kVA / 48kW 80kVA / 64kW
Voltage 380/220 , 400/230 , 415/240 (3Phase, 4-wire plus ground)
Input Voltage Range 208~477 / 120~276 (380/220 rating).
Lower range 208~300 / 120~173Vac is acceptable under 70~100% loading condition.
Input Power Factor > 0.99
Input Current
Harmonic Distortion < 3% (full load)
Output Voltage 380/220 , 400/230 , 415/240 (3Phase, 4-wire plus ground)
Other rating is available in another cabinet (I/P and O/P transformer is included)
Connection Hard wire (Terminal block)
Interface RS232 x 1, Smart Slot x 2, Dry contact output x 6, Contact input x 2, Parallel port x 1,
Battery cabinet temperature x 4
Parallel Link Up to 4 cabinets. Total maximum = 320kVA
Extended Battery
Cabinet Optional
WxDxH (mm) 520 x 850 x 1165
Weight (kg) 125 175 210 244
NH Series Specification
31
Applications
– Networking
– Data centers
– Telecommunications
– Medical
– Banking
– Industrial
• Hot-swappable function to provide uninterruptible
power during module replacement.
• N+X parallel reduncancy(up to 4 cabinets, total max.
=480kVA) for reliability and flexibility, w/o extra
hardware.
• High input power factor (pf > 0.99) and low harmonic
distortion (iTHD < 3%).
• Over 94 % high efficiency.
• Built-in manual and static bypass switch for
maintenance.
• Built-in SRAM, recording maximum 500 real-time
event logs.
• Multi-language LCD display and status LED
indicators.
• Compatible with gnerator installation.
• 6 configurable UPS status dry contact outputs.
• Optional kit for monitoring battery cabinet
temperature.
NH Plus Series 20-120kVA
32
20kVA / 16kW 40kVA / 32kW 60kVA / 48kW 80kVA / 64kW 100kVA/80kW 120kVA/96kW
Voltage 380/220 , 400/230 , 415/240 (3Phase, 4-wire plus ground)
Input Voltage
Range
208~477 / 120~276 (380/220 rating).
Lower range 208~300 / 120~173Vac is acceptable under 70~100% loading condition.
Input Power
Factor > 0.99
Input Current
Harmonic
Distortion
< 3% (full load)
Output Voltage 380/220 , 400/230 , 415/240 (3Phase, 4-wire plus ground)
Other rating is available in another cabinet (I/P and O/P transformer is included)
Connection Hard wire (Terminal block)
Interface RS232 x 1, Smart Slot x 2, Dry contact output x 6, Contact input x 2, Parallel port x 1,
Battery cabinet temperature x 4
Parallel Link Up to 4 cabinets, total maximum = 480kVA
Extended
Battery Cabinet Optional
WxDxH (mm) 520 x 910 x 1165 520 x 975 x 1695
Weight (kg) 170 200 230 260 320 350
NH Plus Series Specification
33
Delta Power Management Software
UPSentry Smart 2000
InsightPower Manager
InsightPower Client
Shutdown Agent
Management software Line condition monitoring
• Real-time UPS status
Management software Dashboard
Display
• Real-time monitoring.
• Multiple views formats: Meters and gauges
Management software Real-time notification
• SMS (Short Message)
• Pager
• SNMP trap
• Network broadcast
• Audible alarm
• External command file
• Receptacle control
…
Management software Scheduling task
• Shutdown/Restart
• Quick test, deep battery test
• Outlet bank control
• Manage remote and local UPS in real-time
• Shutdown/wakeup multiple servers in various operating systems
• Shutdown unattended operating systems and save files
• Provide multi-lingual (English, French, German, Spanish, Portuguese,
Russian, Italian, Polish, Chinese and Japanese)
• Support Windows hibernation feature
• Be compatible with RS232 and USB protocols
• Support SNMP get, set and trap commands
• Equip a built-in mini Web server
• Microsoft platform:
Windows 9x, Me, NT4, 2000, XP, 2003, Vista, Windows 7
• Unix/Linux platform:
- Linux
- IBM AIX
- HP-UX
- Sun Sparc and x86
- FreeBSD
- SCO OpenServer
• Mac OSX
Network
Serial
Master
Slave
Slave
Slave
UPS
HUB
Download Site:
http://59.125.232.140
Management software – UPSentry in a nutshell
Operating Systems supported
Advantages
39
UPS Connectivity
40
SNMP Card ModBus Card
SNMP+5 Ports Switching Hub
This is a special SNMP device with hub
function. It is connected to UPS RS232 port.
Relay I/O Card
EnviroProbe
Real-time temperature/humidity
and other environmental condition
monitoring.
(must combine with SNMP card)
Smart cards are inserted into UPS SNMP slot.
Smart Cards
41
Mini SNMP Card Mini USB Card Mini TVSS Card Mini Relay I/O Card
• Mini Cards are specially designed for UPS equipped with “Mini Slot”.
• For present model, only has such slot.
- E-series
- Gaia-series (5-11 kVA)
Mini Cards
Mini ModBus Card
42
Power range from 0.6-500 kVA
• Delta UPS fall in four categories:
– -
– -
Both single and three phase configurations
• On-line and line-interactive series
Wide range of applications
– PC & Peripherals
– Sever & Networking
– Data Center, Facility & Industrial
– Modular
Delta UPS provide
– Full range of uninterruptible power protection.
– High efficiency for operation cost savings.
– High reliability and performance.
– ISO14001, RoHS compliance.
– World wide service.
Summary