decra estimating sheet shake xd direct to...

2
Colors: Antique Chestnut and Pinnacle Grey *CONSULT LOCAL BUILDING CODES. **HIGH WIND AREAS REQUIRE ADDITIONAL FASTENERS. COPPER AND LEAD ACCESSORIES ARE NOT TO BE USED DUE TO DISSIMILAR METAL REACTION. This estimate is provided in good faith and should not be assumed to reflect the exact components required to roof this plan. DECRA Roofing Systems will not be held liable for the accuracy of this estimate. Project Name: Date: 98090188 – 05/12 Description Profile Color Calculations Total (A) DECRA Shake XD ® 23.4 panels per square 12-3/8” exposure – min pitch 3:12 Squares x 23.4 = Panels (10-15% Waste Factor) DECRA Shake XD ® Panel Vent Ventilation Calculator available at www.decra.com (B) Shake/XD ® Hip & Ridge As needed for hip and ridge 12-5/8” exposure Linear Feet x 12 ÷ 12.5 = Pieces Needed Shake/XD ® End Cap As needed for closure at hip & ridge DECRA Ridge Vent (2) 20’ rolls / package (2) 2-1/2” W x 1” H x 20’ L Linear Feet Ridge ÷ 20 (2) = Rolls Needed Ventilation Calculator available at www.decra.com (C) XD ® Starter Clip with Drip Edge 6’6” Length n/a Linear Feet of Eave ÷ 6.4 = Pieces Needed (Allow for 1” Overlap) (D) XD ® Short Course Clip 6’6” Length n/a Use with standard drip edge & allow for 1” overlap if using as alternative starter. Linear Feet of Eave ÷ 6.4 = Pieces Needed (E) XD ® Rake/Gable Channel For use along rakes/gables 6’6” Length Linear Feet Rake/Gable ÷ 6 = Pieces Needed (Includes 6” Overlap) (F) XD ® Channel For use at roof to side walls, along hips (both sides) (x2) 6’6” Length n/a Linear Feet ÷ 6 = Pieces Needed (x1) for sidewalls, including skylights and chimneys (x2) for hips (Includes 6” overlap) (G) DECRA High-Profile Debris Guard For use along rakes/gables, hips & valleys as needed (2) 1-1/2” W x 1” H x 50’ L n/a Linear Feet Rake/Gable ÷ 50 = Rolls Needed Linear Feet Hips/Valleys ÷ 50 (2) = Rolls Needed (H) XD ® Valley & XD ® Valley Cap 6’6” Length Linear Feet of Valley ÷ 6 = Pieces Needed (Includes 6” Overlap) (I) Shingle/XD ® Underpan Panel Width x 30” (Use with Non-Lead Pipe Jacks) n/a 1 per Roof Penetration Side Flashing For use to counter flash side wall 6’6” Length Linear Feet ÷ 6 = Pieces Needed (Includes 6” Overlap) Flat Sheet 16” x 54” Corrosion Resistant Screws #9 Hex (1/4” diameter) x 1-1/2” long 2,000 / box Use fasteners of sufficient length to penetrate through the sheathing (deck) by at least 1/2” n/a 1 Box (2,000 pcs) per 15 Squares Color Coordinated Corrosion Resistant Screws #9 Hex (1/4” diameter) x 1-1/2” long 500 pc / bag 4 bags / box As needed for Hip & Ridge attachment 1x2 and or 2x2 Timber Battens (Non-Treated) Stacked 2x2s / 1x2s at hips and ridge as needed n/a Touch-Up Kit Use at penetrations, transitions & panels Bag of stone chip & bottle of acrylic base coat DECRA Estimating Sheet Shake XD ® Direct to Deck

Upload: others

Post on 11-Jan-2020

17 views

Category:

Documents


0 download

TRANSCRIPT

Colors: Antique Chestnut and Pinnacle Grey*CONSULT LOCAL BUILDING CODES. **HIGH WIND AREAS REQUIRE ADDITIONAL FASTENERS. COPPER AND LEAD ACCESSORIES ARE NOT TO BE USED DUE TO DISSIMILAR METAL REACTION.

This estimate is provided in good faith and should not be assumed to reflect the exact components required to roof this plan. DECRA Roofing Systems will not be held liable for the accuracy of this estimate.

Project Name: Date:

98090188 – 05/12

Description Profile Color Calculations Total(A) DECRA Shake XD®

23.4 panels per square12-3/8” exposure – min pitch 3:12

Squares x 23.4 = Panels(10-15% Waste Factor)

DECRA Shake XD® Panel Vent Ventilation Calculatoravailable at www.decra.com

(B)Shake/XD® Hip & RidgeAs needed for hip and ridge

12-5/8” exposure

Linear Feet x 12 ÷ 12.5 = Pieces Needed

Shake/XD® End CapAs needed for closure at hip & ridge

DECRA Ridge Vent(2) 20’ rolls / package (2) 2-1/2” W x 1” H x 20’ L

Linear Feet Ridge ÷ 20 (2) = Rolls NeededVentilation Calculator

available at www.decra.com(C)

XD® Starter Clip with Drip Edge

6’6” Lengthn/a

Linear Feet of Eave ÷ 6.4 = Pieces Needed(Allow for 1” Overlap)

(D)XD® Short Course Clip

6’6” Lengthn/a

Use with standard drip edge & allow for 1” overlap if using as alternative starter.

Linear Feet of Eave ÷ 6.4 = Pieces Needed

(E) XD® Rake/Gable ChannelFor use along rakes/gables 6’6” Length

Linear Feet Rake/Gable ÷ 6 = Pieces Needed (Includes 6” Overlap)

(F) XD® ChannelFor use at roof to side walls, along hips

(both sides) (x2) 6’6” Lengthn/a

Linear Feet ÷ 6 = Pieces Needed (x1) for sidewalls, including skylights and chimneys

(x2) for hips (Includes 6” overlap)

(G) DECRA High-Profile Debris GuardFor use along rakes/gables, hips & valleys as needed (2) 1-1/2” W x 1” H x 50’ L n/a

Linear Feet Rake/Gable ÷ 50 = Rolls NeededLinear Feet Hips/Valleys ÷ 50 (2) = Rolls Needed

(H)XD® Valley & XD® Valley Cap

6’6” Length

Linear Feet of Valley ÷ 6 = Pieces Needed(Includes 6” Overlap)

(I) Shingle/XD® UnderpanPanel Width x 30”

(Use with Non-Lead Pipe Jacks)n/a

1 per Roof Penetration

Side FlashingFor use to counter flash side wall

6’6” Length

Linear Feet ÷ 6 = Pieces Needed(Includes 6” Overlap)

Flat Sheet16” x 54”

Corrosion Resistant Screws#9 Hex (1/4” diameter) x 1-1/2” long

2,000 / boxUse fasteners of sufficient length to penetrate through the sheathing (deck) by at least 1/2”

n/a1 Box (2,000 pcs) per 15 Squares

Color Coordinated CorrosionResistant Screws

#9 Hex (1/4” diameter) x 1-1/2” long500 pc / bag4 bags / box

As needed for Hip & Ridge attachment

1x2 and or 2x2 Timber Battens(Non-Treated) Stacked 2x2s / 1x2s at hips and ridge as needed n/a

Touch-Up KitUse at penetrations, transitions & panels Bag of stone chip & bottle of acrylic base coat

DECRA Estimating Sheet Shake XD® Direct to Deck

For Installation Questions Call DECRA Roofing Systems at 800-258-9740

aTin Snips aTape Measure aTable Saw

aCircular Saw aScrew Gun aSpray Paint

aPolyurethane Sealant aHand Seamer aGalvanized Pipe Jacks (No Lead)

aFollow Local Code

aUse 2 x 2s and 1 x 2s as needed to secure Hip & Ridge Pieces along hips and ridges. (should equal the same linear footage as total Hip & Ridge Pieces; each Hip & Ridge Piece equals 12-5/8”)

Above 12:12 pitch use two 2 x 2sBelow 12:12 pitch use one 1 x 2 stacked on one 2 x 2

aClosure strip or tape is recommended in areas where required by code or warranted by weather conditions.

(A) Shake XD® Field Panels (10-15% waste) 23.4 panels per square

(B) Shake/XD® Hip & Ridge (along hip and ridge) Shake/XD® Hip & Ridge Pieces 12-5/8” exposure

(C) XD® Starter Clip with Drip Edge (along eave for starter) 10’ Lengths

(D) XD® Short Course Clip (short course or as alternative to Starter Clip along eave) 10’ Lengths

(E) XD® Rake/Gable Channel (along rake/gable) 6’6” Lengths

(F) XD® Channel (roof-to-wall and along both sides of the hip) 10’ Lengths

(G) XD® Valley 6’6” Lengths

(H) XD® Valley Cap 6’6” Lengths

(I) Shingle/XD® Underpan Panel Width x 30”

Hip & Ridge (B)

XD® Short Course Clip (D)

Lower Roof

ChimneyXD

® Channel (F)

egdi R & pi H) B(

XD® Starter Clip w/Drip Edge (C)

Hip & Ridge (B)

WallGable

Field Panels (A)

XD® Starter Clip w/Drip Edge (C)

Shingle/XD® Underpan (I)

Slope

Slope

Slope

Slope

XD® Starter Clip w/Drip Edge (C)

XD® Rake/Gable Channel (E)

WallField Panels (A)

Field Panels (A)

Field Panels (A)

Field Panels (A) Field Panels (A)

Field Panels (A)

XD® Channel (F)

XD® St

arter

Clip

w/D

rip E

dge (

C)

XD® Ra

ke/G

able

Chan

nel (E

) ) E( XD

® Rake

/Gab

le Ch

anne

lXD

® Star

ter C

lip w

/Drip

Edg

e (C)

XD® Valley (G) & Cap (H) XD ® Valley (G) & Cap (H)

XD® Starter Clip w/Drip Edge (C)

XD® Channel (F) Hip & Ridge (B)

XD® Channel (F)

XD ® Channel (F)

Hip & Ridge (B)

XD ® Channel (F)

XD® Channel (F)

XD® Ra

ke/G

able

Chan

nel (E

)XD

® Rake

/Gab

le Ch

anne

l (E)

98090188 – 05/12

DECRA Estimating Sheet Shake XD® Direct to Deckwww.decra.com