dcim smartzone monitoring and management solutions...
TRANSCRIPT
10/8/2014
DCIM
SmartZone™
Monitoring and Management Solutions:
Portfolio Overview
[08-09-2014]
Alistair Hunt
1
SmartZone Value proposition
Gateways
Power Monitoring
PDU’s
Inline & Clamp Meters
Environmental Monitoring
Access control and Security
Asset & Connectivity Management
Professional Services
DELIVERABLE
DRIVERS
Risk Mitigation
Resilience
Sustainability
Bench mark and regain Capacity
Plan for the future
Optimise, reduce OPEX
Cost Management
Legislation & CSR
REQUIREMENTS
Granular Monitoring
Link Power and Environmental monitoring relationships
Physical Security and Access control
Real time ‘Out of Norm’ exception reporting
Historical analysis reporting
Centralised data collection
Non-Invasive technology [Legacy Data Centres]
Cross department stakeholder reporting
Integration of IT and FM management architectures
Asset Management
Connectivity Management
SmartZone
2
10/8/2014
Mapping to the 6 Zone™ Methodology
6 Zone is a logical, step-by-step methodology of assessing simplified,
individual zones of the data center facility to holistically monitor,
manage, and optimize each zone with greater control.
3
6 Zone™ Methodology
A Holistic Approach to Data Center Management
6 Zone Methodology addresses power, environmental, asset, and connectivity needs
individually by zone or collectively across the entire infrastructure.
1
Zone 1: Fiscal Utility Meters
2
Zone 2: Main Switchboard
Distribution Circuits.
3
Zone 3: Plant Equipment
4 Zone 4: Branch Circuit PDU
6
Zone 6: Device Level
Monitoring
5 Zone 5: Rack & Cabinet
Level Monitoring
4
SmartZone™
Solutions Software
SmartZone™ Solutions Portfolio
Services
Hardware
5
SmartZone™ Hardware
SmartZone™
Solutions Services Software
SmartZone™ Gateway-
Enabled Rack PDUs
SmartZone™ Inline
Meters
SmartZone™ Gateways
SmartZone™ Network-
Enabled Rack PDUs
(and Sensors)
Hardware
Gateway-Enabled Hardware Network-Enabled
Hardware
PViQ Intelligent Patch
Panels (Connectivity
Network-Enabled
Hardware
SmartZone™
Environmental Sensors
SmartZone™
Access and Control
6
IP
Network
SmartZone™ Hardware
World-Class Breadth of Power Monitoring
Network-
Enabled Rack
PDU
Gateway-
Enabled Rack
PDU
Clamp Meter Inline Meters
Applications:
• Typical power
deployment, each
PDU requires an
IP address and
direct connection
to network
• Addresses
standard
requirements of
power and
environmental
monitoring, up to
2 sensors per
PDU
• Do not connect to
gateway
Applications:
• Advanced
environmental
monitoring up to
12+ sensors per
cabinet
• Access control
and beacons
• Switch port
conservation via
connection to
gateway
Applications:
• Non-invasive
power monitoring
for existing single
phase in-cabinet
power
infrastructure
• Utilize gateway
for network
connection
Applications:
• Power
monitoring for
existing in-
cabinet power
infrastructure
• Requires
disconnection
of existing
power to install
between feed
to cabinet and
existing PDU
• Utilize for 3rd
party cabinets
(eg EMC storage
cabinet)
7
SmartZone™ Hardware
Gateway-Enabled Architecture
• Centralizes Device Management
Consolidates multiple devices into a 1RU
gateway through RJ45 ports to simplify
connection and expansion of devices
• Primary/Secondary Network
Interface Design Simplifies the network architectures and
lowers overall power consumption by
retaining all non-essential intelligence,
electronics, and provides DC power
monitoring supply within the gateway
• Utilizes a single IP Address Reduces number of physical IP ports
required, reducing the allocation of capital IP
costs and management overhead
8
SmartZone™ Hardware
Environmental Sensors
Temperature Sensors Detect the air or surface temperature of equipment in and around a rack, cabinet or room in a data center.
Humidity Sensors Measure relative humidity of air and abnormal conditions to ensure the environment does not get too moist or dry, thus preventing damage to equipment.
Airflow Sensors
Measure air velocity in and around a rack, cabinet, ceiling or wall.
PIR Sensors Passive infrared receivers, which constantly monitor the infrared energy levels around a room and recognize change caused by entry of an intruder.
Smoke Sensors Enable immediate data capture and alerting of potentially fatal smoke or fire conditions at different IT and facility domain points, in either new or retrofit installations.
Examples of the types of sensors we carry include
9
SmartZone™ Hardware
Cabinet Access and Controls
Keypad + Electronic
Swing Handle Lock
HID Card Reader +
Electronic Swing
Handle Lock
Gateway
The SmartZone™ EPA064 and EPA126 Gateways are capable of supporting a physical
access control solution for cabinets. There are two options:
10
Third-Party Hardware
Third-Party Power Meters
ZONE 2: Main Switchboard
Distribution
Circuits
ZO
NE
3:
Pla
nt E
qu
ipm
en
t
• Power Meters
• Northern Design MultiCube
• Socomec Diris A20
• Socomec Diris A40/A41
• Schneider PowerMeter PM710
• Schneider PowerMeter PM810
• Schneider PowerLogic ION6200
• Schneider 7550
• IME Nemo 72-L 10781401
• Energy Meters EM21
• Autometers IC-970
• UPS with Modbus Cards or SNMP
• Socomec Green Power Delphys
• Socomec MX/MP Elite
The listed third-party meters above can be read by SmartZone™
Software today to supplement customer solutions.
11
SmartZone™ Hardware
PViQ™ Intelligent Patch Panels (Asset and Connectivity Monitoring)
Industry-first connectivity
management system
that provides:
• Intelligent monitoring of
patch field connectivity
• A zero RU
intelligence module
• A removable
interface unit
• Elimination of individual
active equipment panels
and controllers
PViQ™ Patch Panels
PViQ™ Intelligence Modules
PViQ™ Fiber Trays
12
SmartZone™ Rack Energy Kits
SmartZone™ Rack Energy Kits help small data
centers realize the benefits of DCIM with
specifically designed kits to provide cost-
effective power and environmental monitoring
for small data center environments.
• A simple “out of the box” solution that
includes power and environmental
monitoring hardware and software, to
optimize energy costs and maintain
optimal uptime.
• Designed for small data centers and
telecom closets with 30 or fewer cabinets
or racks (Max of 60 power devices).
INCLUDED IN THE BOX • SmartZone™ Rack Monitoring Software • SmartZone™ Gateway EP042 • SmartZone™ Power Monitoring Device(s)
• Four different kit options • Two Temperature Sensors • One Set of Patch Cords
13
SmartZone™ Rack Energy Kits
Multiple Monitoring Options
SmartZone™ Rack Energy Kit with Rack PDUs An ideal solution for new (greenfield) builds looking to quickly and cost-effectively build in power and environmental monitoring capabilities.
SmartZone™ Rack Energy Kit with Clamp Meters An ideal solution for small data centers looking to quickly add power and environmental monitoring without the hassle or concern of powering down equipment.
SmartZone™ Rack Energy Kit with Zero-RU Inline Meters An ideal solution for small data centers looking to quickly add power and environmental monitoring by cost-effectively upgrading or maximizing current data center resources.
SmartZone™ Rack Energy Kit with 1RU Inline Meter An ideal solution for small data centers looking to quickly and cost-effectively add or build in power and environmental monitoring capabilities for cabinets that require one or more direct power feeds, (such as large servers, disk storage arrays, blade server enclosures, and network switches).
14
How do SmartZone™ Rack Energy Kits Work?
SmartZone™ DCIM Software
SmartZone™
Solutions Services
Hardware
Software
• Rack Monitoring Software
• DCiQ
• PIM
16
SmartZone™ DCIM Software
SmartZone™ Rack Monitoring Software
Included with SmartZone™ Rack Energy Kits, the
SmartZone™ Rack Monitoring Software (formerly ENV-U3)
provides live and historical views of current, temperature
and humidity data readings, coupled with simple trending
information of the parameters monitored.
• Simple desktop application
• Standard SNMP protocol
• Supports up to 60 power devices
• Polls devices and creates and logs
SNMP traps as alerts
• Live and historical view of data
• Simple trending information and management reports
SmartZone™ Rack Monitoring Software is a simple power and environmental software platform
for small data centers or telecom closets with 30 or fewer cabinets
17
SmartZone™ DCIM Software
DCIQ™ Software Platform
As part of the SmartZone™ Software Suite, the DCIQ™
Software Platform is a power and environmental monitoring
and management solution that provides centralized visibility
of energy, cooling, and capacity via networked DCIM
instrumentation.
• World-class scalable data collection engine
• Highly customizable dashboards and
analytics
• Power and environmental real-time
monitoring
• Event management and alarms
• Power control
• Cabinet access control
DCIQ™ is a power and environmental software platform
18
19
Real time reporting and Alarming dashboard
20
Alarm Status report
Reporting Examples, Real time Alerting
21
Reporting Examples, Visual enhancement 22
Report Examples, Zone 6 Device Level
23
Tailored monthly summary report
24
2
Rack power capacity
25
SmartZone™ Software
Panduit Physical Infrastructure Manager™ (PIM™) Software Platform
As part of the SmartZone™ Software Suite, the PIM™
Software Platform is asset and connectivity monitoring
and management solution that tracks the allocation and
utilization of critical IT assets and networking resources,
within your data center and remote sites, while providing
strong visualization and analytics.
• Monitors IT asset information
• Automates connectivity documentation
• Integrates with asset management and
network management platforms
• NEW PIM v5.1 Features include “Best Fit
Capacity” and “Stranded Capacity”
PIM™ is our available asset and connectivity software platform
26
SmartZone™ Solutions Portfolio
Available Today
Implementation Services that provide full-
scale implementation, training, and support
for software and hardware projects:
• Leverage Panduit’s proven
methodologies and industry
best practices
• Provide dedicated training
• Augment your team so that they
can focus on more critical data
center operations.
• Single source of technical
support
SmartZone™
Solutions Services
Hardware
Software
27
Applying SmartZone™ Solutions
Solution Use Cases and Applications
SmartZone™ Solutions help data centers address challenges and opportunities across
physical infrastructure capacity, efficiency (energy and operational) and uptime. Some
examples of challenges that SmartZone™ helps to resolve include:
• Stranded Capacity in Data Centers
o Power
o Cooling
o Space
o Connectivity
• Thermal Performance Optimization
• Remote Management
• Power Distribution Choices and Intelligent
Monitoring
What Are Your Challenges?
28
Questions?
29
building a smarter, unified business foundation
30