dc pinhole/holiday detectors - buckleysinternational.com...dc pinhole/holiday detectors a...
TRANSCRIPT
-
DC Pinhole/Holiday Detectors
tes t fo r defects in coat ings & l in ings over conduct ive mater ia ls
MANUFACTURERS OF SPECIALIST TEST EQUIPMENT
-
DC Pinhole/Holiday DetectorsA high-voltage DC holiday detector is a quick and effective means of locating defects and faults in non-conductive coatings over conductive materials. The detector unit is used in conjunction with a suitable electrode and passed over the entire coating area. Weak spots, faults and pinholes are located by the completion of an electrical circuit through the defect to the conductive material beneath; triggering the detector unit’s alarm.
DC pinhole/holiday detectors have a wide range of applications accross numerous industries; from locating leaks in flat roofs to integrity-testing corrosion resistant coatings on pipelines; from testing cable insulation to locating faults on waterproof bridge-deck coatings.
Buckleys manufacture a wide range of electrodes and accessories for our detectors; designed to make the testing process as effective and as quick as possible. In addition to this, we offer a range of kits which have been created with a specific purpose in mind and include a combination of accessories which are optimised for that application; such as our PD40S and PD30S kits.
We also manufacture electrodes to customers’ specifications as well as offering innovative solutions to unique testing situations or environments.
-
PHD rangeBuckleys PHD1-20 and PHD2-40 tried-and-tested pinhole/holiday detectors are a firm favourite in several industries. Having been in production for a number of years, the PHD range has proven to be dependable and reliable.
The PHD1-20 and PHD2-40 detectors are suitable for checking coating thicknesses of between 20µm-6.5mm and 60µm-25.6mm respectively and are widely used in the petro- chemical, aerospace, pipeline construction and plastic fabrication industries.
PD rangeBuckleys PD6, PD1-30 and PD2-40 pinhole/holiday detectors offer unsurpassed accuracy and reliability in a compact, battery-powered portable unit.
The highly-versatile PD range is available in three outputs; a 0.5kV-6kV version - the PD6 - ideal for testing thinner coatings of between 4µm and 570µm, while the PD1-30 can test coatings thicknesses up to 14.4mm and the PD2-40 is capable of testing thicknesses of up to 25.6mm.
• Lightweight & portable• Quick to set-up and easy to use• Audible & visual fault indicator alarms• Clear backlit LCD• Automatic voltage selector• Accurate sensitivity control
• Displays electrode DC current• Alarm volume control• Power limiter to avoid coating damage• Membrane keypad operation• Wide range of accessories & electrodes available• Existing PHD accessories can be used
• Clear 3½ digit LCD display of test voltage• Audible and visual alarm fault indicators• Safety switch incorporated in handle• Built-in charger unit• Variable sensitivity
• Power limited output for operator safety• Full range of electrodes available• One year ‘back-to-base’ warranty• CE approved
Features
Features
• Housed in a robust metal case• Easy adjustment of test voltage• Clearly readable kV meter• Resettable high-speed counter• Variable alarm and sensitivity
• Visual and audible alarms
• Suitable for low or high speed testing
• Conforms to DC testing of cables BS EN 62230:2007
Features
DCCT rangeThe DCCT is designed to be a static, mains-powered pinhole/holiday detector; ideal for use in automated testing facilities and production lines.
The DCCT’s casing is designed to fit industry-standard mounting racks and is available in four outputs - 1-7.5kV, 2-15kV, 4-30kV and 5-40kV. All variants are available with a test probe handle for manual use or without; for connection to production-line electrodes.
-
Specifications
Also availableWe are able to make a wide variety of electrodes to suit our clients’ requirements and we can offer innovative solutions to simplify the testing process.
We designed and manufactured this bespoke electrode system to test internal coatings on large-diamteter sections of pipework. The electrode system is connected to a DC pinhole/holiday detector and drawn through pipework. It’s stabiliser mechanism ensures 100% contact with the coating through 360°; ensuring all faults are detected.
For more information on Buckleys products, call our sales team on +44 (0)1303 278888, email [email protected] or visit: www.buckleysinternational.com
Buckleys House, Unit G, Concept Court, Shearway Business Park Shearway Road, Folkestone, Kent CT19 4RG, UK
Tel: +44 (0)1303 278888 Fax: +44 (0)1303 274331 Email: [email protected]
www.buckleysinternational.com DCBR/
0716
/CC
Accessories
A103 Interconnecting Lead (PD30/40)
6005-0003
A108 Carry Case(PD range)
6005-0041
A4 Spark Tester
Adaptor 6005-0080
A25 High-Voltage Lead (DCCT)
6005-0071
E0004Gauze Mesh
Electrode 128mm(See Data Sheet E3)
A102High-Capacity D-Cell Battery
6005-0002
E912 Drum Brush Electrode6005-0237
E308 Curved
Phosphor-Bronze Brush Electrodes
6005-0146
A7/A7A/A8 Insulated
Extension Rods6005-0089/-0273/-0090
E920Flexible Probe
Electrode6005-0239
E104Phosphor Bronze
Electrodes(See Data Sheet E1)
A50 Test Voltage Calculator
6005-0083
A26 5m Earth
Lead6005-0073
A38PD/PHD Trailing
Earth Lead6005-0079
A12 Rolling Spring
Electrode Shoe6005-0058
A51 Trim Tool
PHD range66005-0084
Specifications DC voltage Sensitivity Testable Battery Weight Dimensions range range thicknesses life*
PD6 0.5-6kV 10-450µA 4µm-576µm 18 hours* 1.6kg 16cm x 6cm x 20cm
PD1-30 1kV-30kV 10-450µA 16µm-14.4mm 10 hours* 2.0kg 16cm x 6cm x 20cm
PD2-40 2kV-40kV 0-500 µA 64µm-25.6mm 10 hours* 2.0kg 16cm x 6cm x 20cm
PHD1-20 1kV-20kV 0-500 µA 20µm-6.5mm 10 hours** 6.4kg 26cm x 30cm x 22cm
PHD2-40 2kV-40kV 0-500 µA 60µm-25.6mm 7 hours** 6.4kg 26cm x 30cm x 22cm
DCCT 1-7.5kV 1-7.5kV 0-600 µA 16µm-900µm n/aŧ 17kg 50cm x 30cm x 33cm
DCCT 2-15kV 2-15kV 0-600 µA 64µm-3.6mm n/aŧ 17kg 50cm x 30cm x 33cm
DCCT 4-30kV 4-30kV 0-600 µA 256µm-14.4mm n/aŧ 17kg 50cm x 30cm x 33cm
DCCT 5-40kV 5-40kV 0-600 µA 400µm-25.6mm n/aŧ 17kg 50cm x 30cm x 33cmŧDCCT is powered by a mains AC supply. *Tested as BSEN-50356 @ max. output with 10000mAh NiMH cells. **Observed average battery life. Test voltage formula: NACE SP 0274.