Data Center Measurement - Building An ROI Baseline Establishing a baseline measurement of your data center is an important first step in developing a meaningful ROI for any data center project. The cost of energy has recently exceeded the cost of IT equipment; understanding your energy footprint in terms of power consumption and cooling demand has become an important management tool. to view the recorded webinar presentation, please visit http://www.42u.com/measurement-techniques-webinar.htm

TRANSCRIPT

Page 1: Data Center Measurement

42U Confidential ©2008 42U All rights reserved Slide 1

Data Center Measurement – Building An ROI Baseline

August 22, 2008

________________________________

Page 2: Data Center Measurement

Overview

• Big Picture– Why Measure– What to Measure– How To Measure

• Visualization Primer• Case Study• Summary• Q&A

42U Confidential ©2008 42U All rights reserved Slide 2

Page 3: Data Center Measurement

Why Measure

• Service Level Agreement (SLA)• Information Technology

Infrastructure Library (ITIL)• Total Cost of Ownership (TCO)• Actual Versus Designed• Stranded Capacity• “Can’t Manage What You Can’t

Measure”

42U Confidential ©2008 42U All rights reserved Slide 3

Page 4: Data Center Measurement

Energy Cost Projection

42U Confidential ©2008 42U All rights reserved Slide 4

Source: Aperture, Greener Pastures for Your Data Center

Page 5: Data Center Measurement

Energy Benchmark

• Established Benchmark

• Enables Comparison

42U Confidential ©2008 42U All rights reserved Slide 5

Source: The Green Grid

Page 6: Data Center Measurement

Energy Consumers

• 70% of Power Consumption Goes to the Infrastructure

• Over Twice that of the IT Equipment

42U Confidential ©2008 42U All rights reserved Slide 6

Source: The Green Grid, Guidelines for Energy-Efficient Datacenters

Page 7: Data Center Measurement

What To Measure

• Power

• Temperature

• Air Pressure

• Humidity

• Water Flow & Temperature

42U Confidential ©2008 42U All rights reserved Slide 7

Page 8: Data Center Measurement

Best Practice Opportunities

• Chilled Water

• Fans

42U Confidential ©2008 42U All rights reserved Slide 8

Source: Accenture Data Center Energy Forecast Report, July11, 2008

Page 9: Data Center Measurement

How To Measure

• Level of Precision

• Alternatives– Point In Time– Ongoing– Real-Time

• Modeling Tool Requirements

42U Confidential ©2008 42U All rights reserved Slide 9

Page 10: Data Center Measurement

Visualization Tools

• System Admins

• Network Admins

• Data Center Managers

42U Confidential ©2008 42U All rights reserved Slide 10

Page 11: Data Center Measurement

Real-Time Imaging

42U Confidential ©2008 42U All rights reserved Slide 11

Page 12: Data Center Measurement

Real-Time Imaging

42U Confidential ©2008 42U All rights reserved Slide 12

Page 13: Data Center Measurement

CFD Visualization

Computational Fluid Dynamics (CFD)

42U Confidential ©2008 42U All rights reserved Slide 13

Page 14: Data Center Measurement

Case Study

• Lawrence Berkeley National Lab– Continued Increase in Demand– Data Center Capacity ~2011– Strategic Imperative on Efficiency

• Study Results– Improve Airflow– Virtualization– Water Cooling

42U Confidential ©2008 42U All rights reserved Slide 14

Page 15: Data Center Measurement

Efficiency MeasurementLife-CycleTM

42U Confidential ©2008 42U All rights reserved Slide 15

Reconfiguration

• Measurement Points• Measurement Object Database• Security

• Hardware Configuration & Testing• Network Configuration & Testing• Sensor Installation• Software Installation• Network Verification

• Data Collection• Analysis• System Management

• Facilities Data• IT Infrastructure Data• IT Equipment Data• Integration Requirements

Survey

Planning

Installation

Measurement

Page 16: Data Center Measurement

Wireless Sensor Network

42U Confidential ©2008 42U All rights reserved Slide 16

Page 17: Data Center Measurement

Confirmation of Fundamentals

• Impact of a Single Blanking Panel

• Consistent Results For– Floor Leaks– Tile

Arrangement

Top of rack

Middle of rack

42U Confidential ©2008 42U All rights reserved Slide 17

Page 18: Data Center Measurement

Floor Tile Tuning

• One Day Time Investment– 24 Converted

from Perforated to Solid

– 6 Converted from High- to Low- Flow

– 4 Converted from Low- to High- Flow

Before

After

42U Confidential ©2008 42U All rights reserved Slide 18

Page 19: Data Center Measurement

Results of Tuning

• Real-Time Verification

• Eliminates Guesswork

Under-Floor Pressure

Rack-Top Temperatures

42U Confidential ©2008 42U All rights reserved Slide 19

Page 20: Data Center Measurement

Air Flow Tuning

42U Confidential ©2008 42U All rights reserved Slide 20

Page 21: Data Center Measurement

Measureable Correlations

• Real-Time Feedback

• Enhanced Knowledge of Data Center Redundancy Characteristics

Under-Floor Pressure

Rack-Top Temperatures

42U Confidential ©2008 42U All rights reserved Slide 21

Page 22: Data Center Measurement

Summary

• Planning– What To Measure– How To Measure

• Interpreting Results

• Efficiency Improvement Plan– Rank By ROI

42U Confidential ©2008 42U All rights reserved Slide 22

Page 23: Data Center Measurement

Q&A

42U Confidential ©2008 42U All rights reserved Slide 23