dassault falcon 000dx-ex-electrical power

Upload: carlos-armando

Post on 21-Jul-2015

48 views

Category:

Documents


0 download

TRANSCRIPT

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERTABLE OF CONTENTS

02-24-00 PAGE 1 / 2 ISSUE 3

02-24 ATA 24 ELECTRICAL POWER 02-24-00 TABLE OF CONTENTS 02-24-05 GENERAL Introduction Sources Equipment location 02-24-10 DESCRIPTION Generation Distribution Operation 02-24-15 CONTROL AND INDICATION Control Indication 02-24-20 SYSTEM PROTECTION Introduction Batteries Generators and APU Circuit breakers 02-24-25 NORMAL OPERATION Introduction Ground operation with GPU plugged (MINI LOAD MASTER ON) Ground operation with APU operating (LH AV, RH AV and MINI LOAD MASTER ON) Normal flight operation 02-24-30 ABNORMAL OPERATION Introduction BUS tieding and untieding policy Erroneous indication Battery 1 overheat GEN 2 failure CAS messages

DASSAULT AVIATION Proprietary Data

02-24-00 PAGE 2 / 2 ISSUE 3

ATA 24 ELECTRICAL POWERTABLE OF CONTENTS

F2000EX EASY CODDE 1 DGT94085

INTENTIONALLY LEFT BLANK

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERGENERAL

02-24-05 PAGE 1 / 4 ISSUE 3

INTRODUCTION The F2000EX EASy uses DC power for control, operation and indication of the various systems installed in the airplane. The electrical power supply system consists of a 28 VDC on-board generation system designed to minimize electrical fluctuation and power interruption. It supplies, controls and distributes DC power to the on-board electrical equipment through three main buses (LH, ESS and RH buses). Most of the avionics equipment is master switched on these respective buses: LH AV MASTER, MINI LOAD MASTER and RH AV MASTER. The Median (MD) bus is used for liaison purpose. The system is powered by two engine-driven generators and two batteries. It can also be supplied by an Auxiliary Power Unit (APU) driven generator. On ground, it can be supplied by an external DC Ground Power Unit (GPU).

DASSAULT AVIATION Proprietary Data

02-24-05 PAGE 2 / 4 ISSUE 3

ATA 24 ELECTRICAL POWERGENERAL

F2000EX EASY CODDE 1 DGT94085

Master switches Circuit breakers overhead panel

DC supply overhead panel CAS windows

ELEC, STAT and TEST synoptics

FIGURE 02-24-05-00 FLIGHT DECK OVERVIEW

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERGENERAL

02-24-05 PAGE 3 / 4 ISSUE 3

SOURCES DC SOURCES-

AC SOURCES-

two 36 Ah batteries two 12 generators kW engine-driven

equipment requiring alternating current is equipped with built-in inverters passenger convenience items can be powered by inverters on a dedicated network

-

one 9 kW (300 A) APU-driven starter generator 1 Secondary Flight Display (SFD) battery: HORIZ BAT 1 auxiliary battery: AUX BAT (option) 3 batteries for the emergency lighting system 4 buffer batteries for LH DU, UP DU, MAU1 and MAU2. 4 NIC batteries, one batterie per NIC/PROC module of each channel of MAU. Ground Power Unit (GPU)

-

-

-

INTERNAL-

-

-

EXTERNAL

-

DASSAULT AVIATION Proprietary Data

02-24-05 PAGE 4 / 4 ISSUE 3

ATA 24 ELECTRICAL POWERGENERAL

F2000EX EASY CODDE 1 DGT94085

EQUIPMENT LOCATION

FIGURE 02-24-05-01 EQUIPMENT LOCATION

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERDESCRIPTION

02-24-10 PAGE 1 / 10 ISSUE 3

GENERATION MAIN BATTERIES On ground, two 24 V (36 Ah) Ni-Cad batteries provide the primary source of DC power to the entire distribution system prior to APU starting. The BAT 1 supplies electrical power for starting the APU. As soon as one generator is connected, batteries are reloading and flatten generator electrical spikes. They are also capable of an emergency in-flight source of power for a limited period if all engine-driven generators fail. In that case, battery autonomy would be around 78 min (including 5 troubleshooting minutes) with maximum load shedding. The batteries are located in the forward servicing compartment accessible through the forward servicing compartment door. The batteries are ventilated, on the ground, by a battery-powered blower and by aerodynamic air flow in flight. During ground operation, the battery blower is operational when the BAT 1 switch is on. NOTE Very low-charged batteries cannot be connected to the buses, as their contactors need at least 18 VDC to close.

OTHER BATTERIES Three batteries supply the emergency lights. One HORIZ BAT battery supplies Secondary Flight Display (SFD) in case of loss of LH bus for approximately 2 h 40 min. One AUX BAT battery when installed, may supply dedicated equipment. Four MAU-DU BAT buffer batteries supply the LH DU, UP DU, MAU1 and MAU2 so as to prevent them from dimming when the APU starts due to voltage drop . One of these supplies the Centralized Maintenance Computer (CMC) during shutdown. Four NIC batteries supply the NIC/PROC module of each chanel of MAU. Except for the batteries of emergency lights and NIC/PROC module, all battery voltages are monitored and indicated in the TEST synoptic page. The batteries of emergency lights can be checked by a three-position OFF-ON-ARM EMERG LIGHTS switch located on the overhead panel.

DASSAULT AVIATION Proprietary Data

02-24-10 PAGE 2 / 10 ISSUE 3

ATA 24 ELECTRICAL POWERDESCRIPTION

F2000EX EASY CODDE 1 DGT94085

ENGINE-DRIVEN GENERATORS Engine-driven rectifier alternators are driven by the accessory gear box of each engine. A shear shaft in the generator prevents damages to the accessory gearbox in case of generator seizure. A damper in the generator shaft prevents from vibrations. They are rated at 12 kW and regulated at 28.5 VDC by their associated Generator Control Unit (GCU). APU GENERATOR The Auxiliary Power Unit (APU) is equipped with a starter-generator. On ground, it is capable of power the entire DC electrical system, in addition to charging batteries. It is rated at 9 kW and regulated at 28.5 VDC by its associated GCU. ENGINE-DRIVEN GCU The two Generator Control Units (GCU) provide current and voltage control and protection for their associated generator: - Control: the GCU regulates the voltage at 28.5 VDC. It monitors the output current in order to comply with peak power protection (above 400 A). It also provides generator output control in order to balance the voltage between several generators, when connected in parallel. - Protection: the GCU automatically disconnects its associated generator after debounce when the electric load limit is reached or overvoltage. APU-DRIVEN GCU The APU Generator Control Units (GCU) provides current and voltage control and protection for its associated generator: - Control: the GCU regulates the voltage at 28.5 VDC and monitors the output current to 300 A, with a maximum of 350 A for one minute. It also provides generator output control in order to balance the voltage between several generators, when connected in parallel. - Protection: the GCU automatically disconnects the generator when the electric load limit is reached or overvoltage. It also controls APU start sequence.

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERDESCRIPTION

02-24-10 PAGE 3 / 10 ISSUE 3

GPU An approved 28 VDC Ground Power Unit (GPU) may be used for prolonged periods to power the DC system in order to facilitate maintenance and servicing. The GPU may also be used for APU starting (recommended power is 1,000 A). When the GPU is connected and operating, generators and batteries are automatically disconnected from buses. If the airplane is equipped by the option charging batteries by GPU then it is possible to connect batteries to the buses when GPU is connected.

FIGURE 02-24-10-00 GPU RECEPTACLE LOCATION

DASSAULT AVIATION Proprietary Data

02-24-10 PAGE 4 / 10 ISSUE 3

ATA 24 ELECTRICAL POWERDESCRIPTION

F2000EX EASY CODDE 1 DGT94085

DISTRIBUTION GENERAL DC power distribution is separated into three independent buses, allowing redundantly powered systems to continue to safely operate if one bus fails. The distribution system consists of 5 distinct buses: - battery bus, - ESSential bus (A5, ESS), - MD bus (connects battery 2 to RH or ESS buses), - LH bus (A1, A2, A3, CABIN), - RH bus (B1, B2, B3, GALLEY).

FIGURE 02-24-10-01 ELECTRICAL SYSTEM DIAGRAM

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERDESCRIPTION

02-24-10 PAGE 5 / 10 ISSUE 3

The battery bus is powered as soon as the battery 1 is installed and plugged in. Regardless of battery switch position, the battery bus provides electrical power directly to: - the fueling panel, - the emergency slat control circuit, - the APU starter circuit, - the engine FIRE extinguishers secondary discharge, - the fuel shut-off valves, - LIGHT 1 and LIGHT 2, main access door, available if at least one of the five trip magnetic switches is selected to on. Most of the avionics equipment is connected to the main buses through master-switches located on the overhead panel:

FIGURE 02-24-10-02 OVERHEAD PANEL

DASSAULT AVIATION Proprietary Data

02-24-10 PAGE 6 / 10 ISSUE 3

ATA 24 ELECTRICAL POWERDESCRIPTION

F2000EX EASY CODDE 1 DGT94085

LH BUS

ESS BUS

RH BUS

-

ACP 3 Data loader LSS (option) RAD ALT 1 TCAS Weather Radar

-

ADF 1 ADM 1 ATC 1 CCD LH (one channel) CCD RH (one channel) DME 1 GP LH LH DU MAU 2 channel B MKB LH UP DU VOR 1

-

ADF 2 ADM 2 ATC 2 AFCS channels A+B AP servomotors CCD LH (one channel) CCD RH (one channel) DME 2 GP RH LW DU MAU 1 channel B MAU 2 channel A MKB RH RAD ALT 2 RH DU VHF 3 (option) VOR 2 Yaw Damper

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085 LH BUS-

ATA 24 ELECTRICAL POWERDESCRIPTION

02-24-10 PAGE 7 / 10 ISSUE 3

ESS BUS-

RH BUS

a1 AOA HEAT (LH) BOOST 1 CAB LAV MASTER CABIN PRESS COND'G CABIN ENG 1 EDU EXT LIGHTS (LH) FLAP A/B INDIC FUEL 2 SHUT OFF HUD HGS (option) HUD OHU (option) HYDR 1 INDIC INSTR BAT (ST BY) L/G CONTROL LANDING LH LO FUEL NAV NOSE WHL 1 O2 BOX LH OIL LH PITOT HEAT (LH) READING CKPT (LH) REVERSE 1 ARM REVERSE 1 DEPLOY STATIC HEAT (LH) TRIM AILERON WSHLD FRONT LH

ADF 2 - ADM 2 - AOA HEAT (RH) - AFT SIDE WINDOW - AIL FEEL - ATC 2 - AUTO SLAT (RH) - BAG COMPT - BOOST 2 (ST BY) - BRAKE CMPTR 2 - CAB AC MASTER - CCD LH (one channel) - CCD RH (one channel) - COND'G CREW - CREW CALL - ENG 2 - ENG 2 EDU - ENG VIBR - EXTING 1 - FADEC A RH - FLIGHT RECORDER - FUEL CMPTR (RH) - GP RH - IRS2 - L/G INDIC - MAU 1 CH B - MAU 2 BAT - MKB RH - OIL RH - OVERHEAD RH - READING CKPT (RH) - STAB NORMAL - STROBE - TAXI - TCU RH - VALANCE - WARN B AUDIO - WARN B EXT - WARN RH ESS/B (*) - WIPER RH (*) backup powered breakers (red extension on circuit breakers panel)-

ESS A/B CONTROL ADF 1 ADM 1 ANTICOL FIN APU APU DETECT APU EXTING ATC 1 BLEED HP 1 BLEED HP 2 BLEED MONIT (ST BY) BOOST 2 BRAKE CMPTR 1 CCD LH (one channel) CCD RH (one channel) COND'G MAN DETECT 1 DETECT 2 DME 1 DU LH DU UP FADEC A LH FLAP CONTROL FUEL CMPTR (LH) GP LH HYDR ISOL ICS LH ICS RH (ST BY) IGNITION 1 A IGNITION 2 A IRS 1 L/G EMERG MAU 1 CH A MKB LH MRC 1 NIM O2 BOX RH OVERHEAD LH /

b1

DASSAULT AVIATION Proprietary Data

02-24-10 PAGE 8 / 10 ISSUE 3 LH BUS-

ATA 24 ELECTRICAL POWERDESCRIPTION

F2000EX EASY CODDE 1 DGT94085

ESS BUS-

RH BUS-

a2 AUTO SLAT (LH) AV MASTER (LH) BELTS NO SMK'G BRAKE 2 ST BY DU BAT (LH) DU BAT (UP) DV WINDOW ENG1 ENTRY/CEILING EXTING 2 FADEC B LH FLIGHT RECORDER (ST BY) HF 1 ICS 3 IGNITION 1 B IRS 3 MAU 1 BAT PRV1 RAD ALT 1 REV PANEL SHIELD TCAS TEMP PROBE WARN A

ESS (cont'd) PITCH FEEL PITOT (ST BY) PRESS MONIT PUMP (ST BY) STAB EMERG START 1 START 2 TCU LH TRANSFER TRIM RUDDER VDR 1 VHF 1 VOICE RECORDER WARN ESS AUDIO WARN ESS EXT WARN LH ESS/B* WINGS WIPER LH XBP

b2 AFCS CH A AFCS CH B ANTICOL BELLY AP TRIM AP SERVO AV MASTER (RH) BLEED MONIT BOOST 1 (ST BY) CREW SEATS DRAIN HEAT DU RH EMERG LIGHT (*) EXT LIGHTS (RH) FADEC B RH FLASH LIGHT FUEL 1 SHUT OFF FUEL APU SHUT OFF GALLEY MASTER HF 2 HYDR 2 INDIC ICS RH IGNITION 2 B INSTR LANDING RH MAU 2 CH A ML MASTER (RH) MRC 2 NIM NOSE CONE FAN NOSE WHL 2 PITOT HEAT (RH) PRESSURE FUELING PRINTER PRV 2 RAD ALT 2 REVERSE 2 ARM REVERSE 2 DEPLOY ROLL EMERG STATIC HEAT (RH) VHF 2 WSHLD FRONT RH YD

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085 LH BUS

ATA 24 ELECTRICAL POWERDESCRIPTION

02-24-10 PAGE 9 / 10 ISSUE 3

ESS BUS

RH BUS

a3-

a5-

b3-

WINDSHIELD (LH) a4

ST-BY PUMP

WINDSHIELD (RH)

-

AC SYSTEM (option) No breakers are connected to MD bus.

OPERATION ON GROUND When GPU is connected, all buses are automatically tied. RH and LH buses could be untied by selecting LH or RH ISOL pushbutton. NORMAL FLIGHT The bus tied rotary switch is in vertical position, ESS and MD buses are untied. RH and LH ISOL pushbuttons are set to tied (status light unlighted), LH bus is tied to ESS bus, RH buses tied to MD bus. ABNORMAL CONDITIONS In case of one generator failure, the battery supplies that bus.

DASSAULT AVIATION Proprietary Data

02-24-10 PAGE 10 / 10 ISSUE 3

ATA 24 ELECTRICAL POWERDESCRIPTION

F2000EX EASY CODDE 1 DGT94085

INTENTIONALLY LEFT BLANK

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERCONTROL AND INDICATION

02-24-15 PAGE 1 / 12 ISSUE 3

CONTROL

FIGURE 02-24-15-00 OVERHEAD PANEL DURING NORMAL FLIGHT CONFIGURATION

SYNTHETIC TABLE CONTROL-

FUNCTION GEN 1 connects generator 1 to the LH bus GEN 2 connects generator 2 to the RH bus trip automatically to down position when the GCU detects an anomaly (over voltage, over current) act as reset switches when the fault is cleared (only one reset attempt is allowed)

TO ACTIVATE TO DEACTIVATE

SYNOPTIC

On: contactor is closed

-

two-position trip magnetic switch-

Connected

Off: contactor is open and engine stopped or GPU is On Abnormal situation: contactor is open and engine is running and there is no GPU

two-position trip magnetic switch

-

Disconnected

GEN1

DASSAULT AVIATION Proprietary Data

02-24-15 PAGE 2 / 12 ISSUE 3

ATA 24 ELECTRICAL POWERCONTROL AND INDICATION

F2000EX EASY CODDE 1 DGT94085

CONTROL

FUNCTION

TO ACTIVATE TO DEACTIVATE

SYNOPTIC Contactor closed and GPU is off (except GPUpowered APU starting) Contactor open and GPU is on (except during APU starting) Abnormal situation: contactor open without GPU Abnormal situation: contactor is closed and GPU is on

-

BAT 1 connects battery 1 to the ESS bus

BAT1

NOTE Battery 1 supplies the battery bus whatever battery switch position-

two-position trip magnetic switch

Connected

BAT 2 connects battery 2 to the MD bus

-

trip automatically to down position when the system detects an anomaly (high reverse current) act as reset switches when the fault is cleared Disconnected

-

two-position trip magnetic switch

Abnormal situation: overheating

BAT1

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERCONTROL AND INDICATION

02-24-15 PAGE 3 / 12 ISSUE 3

CONTROL

FUNCTION

TO ACTIVATE TO DEACTIVATE

SYNOPTIC contactor closed (below 35,500 ft)

-

connects the APU generator to the ESS bus trips automatically to down position when the GCU detects an overvoltage, acts as a reset switch when the fault is cleared (only one reset attempt is allowed)

Connected

contactor closed (above 35,500 ft)

-

two-position trip magnetic switch

-

contactor open (APU stopped or GPU is on)

Disconnected

Abnormal situation: contactor open with APU running and no GPU

ON GROUND ONLY:-

disconnects the batteries from their respective buses, independently from BAT magnetic switch position ties up all buses whatever BUS TIED rotary switch position allows GPU to supply all buses

On: airplane powered by GPU on ground Push On

light pushbutton

-

-

Off: airplane not powered by GPU Push Off

DASSAULT AVIATION Proprietary Data

02-24-15 PAGE 4 / 12 ISSUE 3

ATA 24 ELECTRICAL POWERCONTROL AND INDICATION

F2000EX EASY CODDE 1 DGT94085

CONTROL

FUNCTION

TO ACTIVATE TO DEACTIVATE

SYNOPTIC Contactor normally tied

Turn horizontally-

Abnormally untied (rotary switch horizontal or EXT POWER pushed on)

ties up ESS (left side) and MD (right side) buses

BUS TIED rotary switch Contactor normally untied Turn vertically Abnormally tied (rotary switch vertical with no GPU) Contactor closed

-

isolates LH bus from ESS bus or RH bus from MD bus

Push on

Contactor abnormally isolated

Contactor normally isolated

Push off

Contactor abnormally closed

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERCONTROL AND INDICATION

02-24-15 PAGE 5 / 12 ISSUE 3

CONTROL

FUNCTION

TO ACTIVATE TO DEACTIVATE Push on (connected)

SYNOPTIC

-

sheds cabin optional equipment load from the LH bus Push off (shed)

No specific indication on the ELEC synoptic

Push on (connected)-

supplies power to LH AV equipment Push off (shed)

No specific indication on the ELEC synoptic

Push on (connected)-

supplies power to MINI LOAD equipment Push off (shed)

No specific indication on the ELEC synoptic

Push on (connected)-

supplies power to RH AV equipment Push off (shed)

No specific indication on the ELEC synoptic

DASSAULT AVIATION Proprietary Data

02-24-15 PAGE 6 / 12 ISSUE 3

ATA 24 ELECTRICAL POWERCONTROL AND INDICATION

F2000EX EASY CODDE 1 DGT94085

CONTROL

FUNCTION

TO ACTIVATE TO DEACTIVATE Push on (connected)

SYNOPTIC

-

sheds galley equipment load from the RH bus Push off (shed) Switch ARM (in flight normal position)

No specific indication on the ELEC synoptic

-

ON: Illuminates EMERG lights and checks their three batteries

Switch ON (test position) Switch OFF No specific indication on the ELEC synoptic

switch

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERCONTROL AND INDICATION

02-24-15 PAGE 7 / 12 ISSUE 3

INDICATION Electrical system indications are displayed on two pages on the MDU:-

ELEC synoptic, STAT synoptic.

FIGURE 02-24-15-01 ELECTRICAL SYNOPTIC

DASSAULT AVIATION Proprietary Data

02-24-15 PAGE 8 / 12 ISSUE 3

ATA 24 ELECTRICAL POWERCONTROL AND INDICATION

F2000EX EASY CODDE 1 DGT94085

EXAMPLES OF BATTERY TEMPERATURE INDICATION

Warm temperature: indication displayed on amber background

Hot temperature: indication displayed on red background

Invalid data

FIGURE 02-24-15-02 BATTERY TEMPERATURE INDICATION

For each battery, temperature indication is given by the pointer position on an analog scale and by digital readout. When the airplane is not equipped with temperature control (lead acid batteries), none of the above symbols and indication are displayed (option). The scale is colored in white below 49C, in amber between 49C and 71C and in red above 71C. EXAMPLES OF BATTERY AMMETER

Normal values displayed in green

Abnormal values displayed in amber

Invalid data

FIGURE 02-24-15-03 BATTERY AMMETER

For each battery, current indication is given by the pointer position on an analog scale and by digital readout. The scale is colored in amber below 300 A and, when APU is not starting, above + 45 A ; otherwise in white. NOTE A negative current designates a charging current.

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERCONTROL AND INDICATION

02-24-15 PAGE 9 / 12 ISSUE 3

EXAMPLES OF DC GENERATOR AMMETER

Normal values displayed in green

Abnormal values displayed in amber

Invalid data

FIGURE 02-24-15-04 DC GENERATOR AMMETER

NOTE For any generator or battery, 0 A is displayed on synoptic ammeters when actual current is between - 10 A and + 10 A. Current indication is displayed by the pointer position on an analog scale and by digital readout. For both engine-driven generators, indication is permanent and the scale is colored in amber: - on ground, above 300 A, - in flight, above 400 A. For the APU generator, the ammeter is displayed in grey when the APU MASTER pushbutton is ON. Then, above 99% APU N1, the colored indication is displayed. Amber limitations are displayed: - up to 10,000 ft, above 300 A, - between 10,000 ft and 25,000 ft, above 250 A, - above 25,000 ft, above 200 A.

DASSAULT AVIATION Proprietary Data

02-24-15 PAGE 10 / 12 ISSUE 3

ATA 24 ELECTRICAL POWERCONTROL AND INDICATION

F2000EX EASY CODDE 1 DGT94085

EXTERNAL POWER AMMETER

Normal values displayed in green

Abnormal values displayed in amber

Invalid data

FIGURE 02-24-15-05 DC EXTERNAL POWER AMMETER

For the external power ammeter, current indication is displayed on a digital readout when, on ground, EXT POWER light pushbutton is pushed on. The green display turns amber if current exceeds 300 A, except during GPU-powered APU starting (thresholds are modified with GPU batteries charging option).

STARTING PHASE White START is placed under the APU ammeter during APU start. Amber START is placed under the APU in case of abnormal electric power supply.

FIGURE 02-24-15-06 STARTING PHASE

During the APU starting phase, the battery color code of the ELEC synoptic is specific:

-

, BAT 1 contactor opens during APU start, whenever another electrical power is connected to buses (though contactor is open, ammeter deviates during APU start) and GPU is not connected. The symbol turns amber to indicate abnormal closed contactor.

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERCONTROL AND INDICATION

02-24-15 PAGE 11 / 12 ISSUE 3

-

BAT1

, BAT 1 contactor closes if none electrical power is connected or during GPU

assisted APU start. The symbol turns amber to indicate abnormal open contactor.

-

, BAT 2 contactor opens during APU start. The symbol turns amber to indicate abnormal closed contactor.

EXAMPLES OF LH AND RH BUSES VOLTMETER

Normal values displayed in green

Abnormal values displayed in amber

Invalid data

FIGURE 02-24-15-07 BUSES VOLTMETER

LH and RH buses are permanently monitored through two voltmeters displayed in the synoptic page. The ESS bus voltmeter is displayed when essential and LH buses are untied. The MD bus voltmeter is displayed when MD bus (and its battery 2) is isolated from both ESS and RH buses. When a generator supplies the bus, the range of the analog scale is colored in amber below 25 V and above 30 V. This range is different in case of other electric configuration (bus supplied by batteries only, APU starting, ). NOTE Electrical information is also available on the STAT synoptic.

DASSAULT AVIATION Proprietary Data

02-24-15 PAGE 12 / 12 ISSUE 3

ATA 24 ELECTRICAL POWERCONTROL AND INDICATION

F2000EX EASY CODDE 1 DGT94085

STATUS SYNOPTICSystem failure area Failure consequence area

Buses voltage and generators current indications

FIGURE 02-24-15-08 STATUS SYNOPTIC

TEST SYNOPTIC

FIGURE 02-24-15-09 TEST SYNOPTIC

To check MAU / DU BAT or HORIZ BAT, ..., place the CCD cursor on the respective soft key and keep the button pressed to have indications displayed. Normal values appear in green while too low or too high values appear in amber.

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERSYSTEM PROTECTION

02-24-20 PAGE 1 / 4 ISSUE 3

INTRODUCTION Feeder cables are protected by current fuses located inside the two main electrical boxes. Circuit protection is provided by conventional trip-free circuit breakers located on the circuit breakers panel. The circuit breakers panel is divided into different sections. Each section, delimited by different colored frames, corresponds to airplane major systems. In case of failure of one engine-driven generator, certain items, not essential for the flight, are automatically load-shed. The auto load-shed system is disabled when the airplane is on the ground, allowing normal operation of all cabin facilities. The BUS TIED rotary switch normal flight position is vertical, isolating left side buses from right ones. In case of overvoltage or short-circuit on one side, the other side is not affected. The ESS and MD buses can be temporary tied, for ground operations with no engine-driven generator assistance for example. When ESS and MD buses are tied, the contactor provides protection between them in case of overload on one side.

BATTERIES The batteries are protected against excessive load by a trip magnetic switch, which opens and disconnects the battery when the charging (reverse) current exceeds 330 A for more than 3 sec. The BAT magnetic switch trips off and BAT .. CAS message appears.

NOTE Only two reset attempts permitted. Batteries are ventilated on ground and in flight to protect them (hydrogen accumulation, heating). On ground, the ventilation by an electrical blower is operational when the BAT 1 trip magnetic switch is up and the position of the EXT POWER pushbutton is off. In flight, ventilation is provided by the effect of dynamic air flowing through a venting duct and blowing on the batteries.

DASSAULT AVIATION Proprietary Data

02-24-20 PAGE 2 / 4 ISSUE 3

ATA 24 ELECTRICAL POWERSYSTEM PROTECTION

F2000EX EASY CODDE 1 DGT94085

GENERATORS AND APU The engine-driven generators and the APU are each monitored by a GCU. Main protections are:-

voltage control (at 28.5 VDC) and protection, electric load protection, reverse current, ...

The magnetic switch may trip off the corresponding generator. GEN .. CAS message will appear.

CIRCUIT BREAKERS

FIGURE 02-24-20-00 CIRCUIT BREAKERS PANEL

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERSYSTEM PROTECTION

02-24-20 PAGE 3 / 4 ISSUE 3

CIRCUIT BREAKER COLOR CODE

ESS BUS

A1 and A2 BUS

B1 and B2 BUS EMERG LIGHTS WARNING RH ESS / B WARNING LH ESS / B To be pulled if all generators fail

NOTE Red breakers are backup powered by another bus.

DASSAULT AVIATION Proprietary Data

02-24-20 PAGE 4 / 4 ISSUE 3

ATA 24 ELECTRICAL POWERSYSTEM PROTECTION

F2000EX EASY CODDE 1 DGT94085

INTENTIONALLY LEFT BLANK

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERNORMAL OPERATION

02-24-25 PAGE 1 / 6 ISSUE 3

INTRODUCTION In the following, typical ground and in-flight situations have been selected to help the crew to understand the symbols provided in the various panels and displays.

DASSAULT AVIATION Proprietary Data

02-24-25 PAGE 2 / 6 ISSUE 3

ATA 24 ELECTRICAL POWERNORMAL OPERATION

F2000EX EASY CODDE 1 DGT94085

GROUND OPERATION WITH GPU PLUGGED (MINI LOAD MASTER ON)

FIGURE 02-24-25-00 OVERHEAD PANEL DURING GPU OPERATION

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERNORMAL OPERATION

02-24-25 PAGE 3 / 6 ISSUE 3

FIGURE 02-24-25-01 ELECTRICAL SYNOPTIC DURING GPU OPERATION

ACTION

RESULT

Plug in the GPU which is not running.

No result

Turn on GPU (at 28 VDC) Push on EXT PWR light pushbutton

-

green light on all MASTER: OFF lights on MINI LOAD MASTER: OFF light off GPU ON: BUS TIED CAS message

-

Push on MINI LOAD MASTER

-

symbol all GEN and BAT isolated (grey synoptic symbols) BUS TIED amber indication LH and RH buses voltage indications

-

DASSAULT AVIATION Proprietary Data

02-24-25 PAGE 4 / 6 ISSUE 3

ATA 24 ELECTRICAL POWERNORMAL OPERATION

F2000EX EASY CODDE 1 DGT94085

GROUND OPERATION WITH APU OPERATING (LH AV, RH AV AND MINI LOAD MASTER ON)

FIGURE 02-24-25-02 OVERHEAD PANEL DURING APU OPERATION

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERNORMAL OPERATION

02-24-25 PAGE 5 / 6 ISSUE 3

FIGURE 02-24-25-03 ELECTRICAL SYNOPTIC DURING APU OPERATION

ACTION BAT overhead panel trip magnetic switches up position

RESULT

No result-

BAT symbols in green LH and RH buses voltage indications GEN in stand-by + symbol in grey BUS TIED contactor symbol in green, closed BUS TIED amber indication on the ELEC synoptic APU synoptic symbol in green when connected to ESS bus

MINI LOAD MASTER overhead panel pushbutton pushed on

-

BUS TIED rotary switch in horizontal position

-

APU starting procedure

-

LH and RH AV MASTER overhead panel pushbuttons pushed on

-

LH and RH AV MASTER: OFF lights off

DASSAULT AVIATION Proprietary Data

02-24-25 PAGE 6 / 6 ISSUE 3

ATA 24 ELECTRICAL POWERNORMAL OPERATION

F2000EX EASY CODDE 1 DGT94085

NORMAL FLIGHT OPERATION

FIGURE 02-24-25-04 OVERHEAD PANEL DURING NORMAL FLIGHT OPERATION

FIGURE 02-24-25-05 ELECTRICAL SYNOPTIC DURING NORMAL FLIGHT OPERATION

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERABNORMAL OPERATION

02-24-30 PAGE 1 / 10 ISSUE 3

INTRODUCTION In the following, typical abnormal situations have been selected to help the crew to understand the symbols provided in the various panels and displays.

BUS TIEDING AND UNTIEDING POLICY NORMAL FLIGHT CONDITION

FIGURE 02-24-30-00 NORMAL FLIGHT CONDITION-

GEN 1 and BAT 1 supply LH and ESS coupled buses, GEN 2 and BAT 2 supply RH and MD coupled buses.

GENERATOR FAILURE-

At GEN 1 failure (or engine 1), LH bus is maintained coupled to ESS bus, All the equipment supplied by LH bus and ESS bus are available.

FIGURE 02-24-30-01 GENERATOR FAILURE WITH SLATS EXTENDED

the ESS and MD buses must be tied via the bus tied rotary switch.

FIGURE 02-24-30-02 BUS TIED-

GEN 2, BAT 1 and BAT 2 (eventually APU as required) supply the four buses.

DASSAULT AVIATION Proprietary Data

02-24-30 PAGE 2 / 10 ISSUE 3

ATA 24 ELECTRICAL POWERABNORMAL OPERATION

F2000EX EASY CODDE 1 DGT94085

SECOND GENERATOR FAILURE

FIGURE 02-24-30-03 ONE GEN FAILED

At second generator failure : - LH bus is automatically isolated from ESS bus, : o LH ISOL status light displayed, - RH bus is automatically isolated from MD bus: o RH ISOL status light displayed.

FIGURE 02-24-30-04 SECOND GENERATOR FAILURE

BAT 1 and BAT 2 (eventually APU as required) supply ESS and MD buses.

BATTERY 1 OVERHEAT ABNORMAL STATUS

FIGURE 02-24-30-05 OVERHEAD PANEL DURING BAT 1 OVERHEAT

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERABNORMAL OPERATION

02-24-30 PAGE 3 / 10 ISSUE 3

FIGURE 02-24-30-06 ELECTRICAL SYNOPTIC DURING BAT 1 OVERHEAT

CONTEXT

RESULT

-

HOT BAT 1

CAS message

Battery temperature > 71.1C (160F)-

Battery 1 overheat

MASTER

-

WARNING

light on

-

ELEC synoptic: BAT 1 symbol in red + BAT 1 temperature indication in red

DASSAULT AVIATION Proprietary Data

02-24-30 PAGE 4 / 10 ISSUE 3

ATA 24 ELECTRICAL POWERABNORMAL OPERATION

F2000EX EASY CODDE 1 DGT94085

AFTER PROCEDURE COMPLETE

FIGURE 02-24-30-07 OVERHEAD PANEL AFTER BAT 1 SWITCHED OFF

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERABNORMAL OPERATION

02-24-30 PAGE 5 / 10 ISSUE 3

FIGURE 02-24-30-18 ELECTRICAL SYNOPTIC AFTER BAT 1 SWITCHED OFF

ACTION

RESULT

-

BAT 1 isolated BAT 1 Wait until HOT BAT 1 CAS message disappears (battery temperature < 71C) WARM BAT 1 CAS message CAS message

BAT 1 overhead panel trip magnetic switch set to down position

-

When HOT BAT 1 disappears,-

ELEC synoptic: BAT 1 symbol in amber BAT 1 temperature indication in amber, decreasing

DASSAULT AVIATION Proprietary Data

02-24-30 PAGE 6 / 10 ISSUE 3

ATA 24 ELECTRICAL POWERABNORMAL OPERATION

F2000EX EASY CODDE 1 DGT94085

GEN 2 FAILURE ABNORMAL STATUS

FIGURE 02-24-30-08 OVERHEAD PANEL DURING GEN 2 FAILURE

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERABNORMAL OPERATION

02-24-30 PAGE 7 / 10 ISSUE 3

FIGURE 02-24-30-09 ELECTRICAL SYNOPTIC DURING GEN 2 FAILURE

CONTEXT

RESULT

-

GEN 2

CAS message

-

GEN 2 failure detected

-

light on ELEC synoptic: GEN 2 symbol in amber

DASSAULT AVIATION Proprietary Data

02-24-30 PAGE 8 / 10 ISSUE 3

ATA 24 ELECTRICAL POWERABNORMAL OPERATION

F2000EX EASY CODDE 1 DGT94085

AFTER PROCEDURE COMPLETE

FIGURE 02-24-30-10 OVERHEAD PANEL WITH GEN 2 SWITCHED OFF AND BUS TIED

DASSAULT AVIATION Proprietary Data

F2000EX EASY CODDE 1 DGT94085

ATA 24 ELECTRICAL POWERABNORMAL OPERATION

02-24-30 PAGE 9 / 10 ISSUE 3

FIGURE 02-24-30-11 ELECTRICAL SYNOPTIC WITH GEN 2 SWITCH TRIPPED OFF AND BUS TIED ON

ACTION-

RESULT

GEN 2 overhead panel trip magnetic switch set to down position

-

BUS TIED rotary switch set to tied position (horizontal position)

-

symbol on ELEC synoptic

-

symbol on ELEC synoptic RH ISOL status light off BUS RH TIED and GEN 2 CAS messages

RH ISOL pushbutton depressed

-

DASSAULT AVIATION Proprietary Data

02-24-30 PAGE 10 / 10 ISSUE 3

ATA 24 ELECTRICAL POWERABNORMAL OPERATION

F2000EX EASY CODDE 1 DGT94085

CAS MESSAGES CAS MESSAGE 2 GENS FAIL HOT BAT .. APU GEN BAT .. BAT .. TEMP INOP BUS ESSENTIAL LOW VOLTAGE BUS ESSENTIAL OVERVOLTAGE BUS XX ISOL BUS XX LOW VOLTAGE BUS XX OVERVOLTAGE BUS RH TIED GEN .. OVHD BACKUP PWR LH+RH FAIL STARTER APU WARM BAT .. APU GEN FAIL BAT .. TEMP INOP BUS RH TIED GEN .. FAIL GPU ON: BUS TIED OVHD BACKUP PWR XX FAIL DEFINITION The two electrical generator connections have failed and at least one engine is running Temperature of one battery above 71C (160F) APU generator not connected with APU running Battery (1/2) contactor open (except during APU starting or GPU power supply) Battery (1/2) temperature probe inoperative (on ground) Low voltage on essential bus Overvoltage on essential bus (LH/RH) ISOL bus contactor is open (LH/RH) bus voltage lower than 24 V with one generator connected (LH/RH) bus voltage above 32 V BUS TIED contactor is tied while rotary switch is turned to untied, without GPU, RH ISOL is not pushed to ISOL One generator failed to connect though its engine is running, without GPU (LH/RH) backup power supply in overhead panel not operative on ground APU on and its starter still active Battery (1/2) temperature between 49C (120F) and 71C On ground, APU contactor failed to open Battery (1/2) temperature measurement invalid BUS TIED contactor is tied with rotary switch turned to tied, without GPU, RH ISOL is not pushed to ISOL On ground, GEN (1/2) contactor failed to open without engine running or with GPU on Airplane powered by GPU and bus tied is automatically tied. (LH/RH) backup power supply for overhead panel fails

DASSAULT AVIATION Proprietary Data