DANFOSS - FCD 300 Configuration for Conveyor PNU # Display Text Parameter Description User-set value Operation and Display 001 LANGUAGE Language [0] ENGLISH 002 OPERATION SITE Local/Remote Operation [0] REMOTE 003 LOCAL REFERENCE Local reference 20.000 Hz 004 ACTIVE SETUP Active Setup [1] SETUP 1 005 EDIT SETUP Programming Setup [5] ACTIVE SETUP 006 SETUP COPY Setup copying [0] NO COPY 007 LCP COPY LCP copy [0] NO COPY 008 FREQUENCY SCALE Display scaling of output frequency 1.00 009 DISPLAY LINE 2 Large display readout [4] FREQUENCY [Hz] 010 DISPLAY LINE 1.1 Small display line 1.1 [1] REFERENCE [%] 011 DISPLAY LINE 1.2 Small display line 1.2 [6] MOTOR CURRENT [A] 012 DISPLAY LINE 1.3 Small display line 1.3 [8] POWER [kW] 013 LOC CTRL/CONFIG. Local Control [4] LOC+DIG CTRL/AS P100 014 LOCAL STOP Local Stop [1] ENABLE 015 LOCAL JOGGING Local Jog [0] DISABLE 016 LOCAL REVERSING Local reversing [0] DISABLE 017 LOCAL RESET Local reset of trip [1] ENABLE 018 DATA CHANGE LOCK Lock for data change [0] NOT LOCKED 019 POWER UP ACTION Operating mode at Power-up, local operation [1] LOCAL = STOP 020 HAND OPERATION DISABLE 024 USER QUICKMENU Userdefined Quick Menu [0] DISABLE 025 QUICK MENU SETUP Quick Menu setup [1] 000 026 LED STATUS LED Status [0] OVERLOAD Load and motor 100 CONFIG. MODE Configuration [0] SPEED OPEN LOOP 101 TORQUE CHARACT Torque characteristics [1] CONSTANT TORQUE 102 MOTOR POWER 1.10 kW 103 MOTOR VOLTAGE 400 V 104 MOTOR FREQUENCY 50 Hz 105 MOTOR CURRENT 2.80 A 106 MOTOR NOM. SPEED Rated Motor Speed 1420 RPM 107 AUTO MOTOR TUN. Automatic motor tuning, ATM [0] AMT OFF 108 STATOR RESISTAN 6.000 OHM 109 STATOR REACTANCE 180.00 OHM 117 RESONANCE DAMP. Resonance dampening 0% 119 HIGH START TORQ. High start torque OFF (0.0 sec) 120 START DELAY Start delay 0.0 sec 121 START FUNCTION Start function [2] COAST/DELAY TIME 122 FUNCTION AT STOP Function at stop [0] COAST 123 MIN.F. FUNC.STOP Min. frequency for activating of function at st 0.1 Hz 126 DC BRAKING TIME DC braking time 10 sec 127 DC BRAKE CUT-IN DC brake cut-in frequency 0.0 Hz (OFF) 128 MOT.THERM PROTECT Thermal motor protection [4] ETR TRIP 1 130 START FREQUENCY Start frequency 0.0 Hz 131 INITIAL VOLTAGE Initial voltage 0.0 Volt 132 DC BRAKE VOLTAGE DC brake voltage 0 % (OFF) 133 START VOLTAGE Start voltage 12.67 V 134 LOAD COMPENSATIO Load compensation 100% 135 U/F RATIO U/f-ratio 7.56 136 SLIP COMP. Slip compensation 100% 137 DC HOLD VOLTAGE DC hold voltage 0% 138 BRAKE CUT OUT Brake cut out value 3.0 Hz 139 BRAKE CUT IN Brake cut in frequency 3.0 Hz 140 CURRENT MIN VAL Current, minimum value 10% 142 LEAK. REACTANCE 18.000 OHM Motor Power PM,N Motor Voltage UM,N Motor Frequency fM,N Motor Current IM,N Stator resistance RS Stator reactance XS Leakage reactance XL

Upload: hieu-vo-quoc

Post on 27-Oct-2014

95 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Danfos - Fcd 300 Config

DANFOSS - FCD 300 Configuration for Conveyor M6 / Beer Filler

PNU # Display Text Parameter Description User-set valueOperation and Display

001 LANGUAGE Language [0] ENGLISH

002 OPERATION SITE Local/Remote Operation [0] REMOTE

003 LOCAL REFERENCE Local reference 20.000 Hz

004 ACTIVE SETUP Active Setup [1] SETUP 1

005 EDIT SETUP Programming Setup [5] ACTIVE SETUP

006 SETUP COPY Setup copying [0] NO COPY

007 LCP COPY LCP copy [0] NO COPY008 FREQUENCY SCALE Display scaling of output frequency 1.00

009 DISPLAY LINE 2 Large display readout [4] FREQUENCY [Hz]

010 DISPLAY LINE 1.1 Small display line 1.1 [1] REFERENCE [%]

011 DISPLAY LINE 1.2 Small display line 1.2 [6] MOTOR CURRENT [A]

012 DISPLAY LINE 1.3 Small display line 1.3 [8] POWER [kW]

013 LOC CTRL/CONFIG. Local Control [4] LOC+DIG CTRL/AS P100014 LOCAL STOP Local Stop [1] ENABLE

015 LOCAL JOGGING Local Jog [0] DISABLE

016 LOCAL REVERSING Local reversing [0] DISABLE

017 LOCAL RESET Local reset of trip [1] ENABLE

018 DATA CHANGE LOCK Lock for data change [0] NOT LOCKED

019 POWER UP ACTION Operating mode at Power-up, local operation [1] LOCAL = STOP

020 HAND OPERATION DISABLE

024 USER QUICKMENU Userdefined Quick Menu [0] DISABLE

025 QUICK MENU SETUP Quick Menu setup [1] 000

026 LED STATUS LED Status [0] OVERLOAD

Load and motor100 CONFIG. MODE Configuration [0] SPEED OPEN LOOP

101 TORQUE CHARACT Torque characteristics [1] CONSTANT TORQUE

102 MOTOR POWER 1.10 kW

103 MOTOR VOLTAGE 400 V

104 MOTOR FREQUENCY 50 Hz

105 MOTOR CURRENT 2.80 A

106 MOTOR NOM. SPEED Rated Motor Speed 1420 RPM

107 AUTO MOTOR TUN. Automatic motor tuning, ATM [0] AMT OFF

108 STATOR RESISTAN 6.000 OHM

109 STATOR REACTANCE 180.00 OHM

117 RESONANCE DAMP. Resonance dampening 0%

119 HIGH START TORQ. High start torque OFF (0.0 sec)

120 START DELAY Start delay 0.0 sec

121 START FUNCTION Start function [2] COAST/DELAY TIME

122 FUNCTION AT STOP Function at stop [0] COAST

123 MIN.F. FUNC.STOP Min. frequency for activating of function at stop 0.1 Hz

126 DC BRAKING TIME DC braking time 10 sec

127 DC BRAKE CUT-IN DC brake cut-in frequency 0.0 Hz (OFF)

128 MOT.THERM PROTECT Thermal motor protection [4] ETR TRIP 1

130 START FREQUENCY Start frequency 0.0 Hz

131 INITIAL VOLTAGE Initial voltage 0.0 Volt

132 DC BRAKE VOLTAGE DC brake voltage 0 % (OFF)

133 START VOLTAGE Start voltage 12.67 V

134 LOAD COMPENSATIO Load compensation 100%

135 U/F RATIO U/f-ratio 7.56

136 SLIP COMP. Slip compensation 100%

137 DC HOLD VOLTAGE DC hold voltage 0%

138 BRAKE CUT OUT Brake cut out value 3.0 Hz

139 BRAKE CUT IN Brake cut in frequency 3.0 Hz

140 CURRENT MIN VAL Current, minimum value 10%

142 LEAK. REACTANCE 18.000 OHM

Motor Power PM,N

Motor Voltage UM,N

Motor Frequency fM,N

Motor Current IM,N

Stator resistance RS

Stator reactance XS

Leakage reactance XL

Page 2: Danfos - Fcd 300 Config

144 GAIN AC BRAKE Gain AC brake 1.30

146 RESET VECTOR Reset voltage vector [0] OFF

148 MOTOR TYPE GENERAL

References and limits200 OUT FREQ RNG/ROT Output frequency range [0] 132 Hz CLOCK WISE

201 MIN. OUTPUT FREQ. 0.0 Hz

202 MAX, OUTPUT FREQ. 132.0 Hz

203 REFERENCE RANGE Reference range [0] MIN - MAX

204 MIN. REFERENCE 0.000 Hz205 MAX. REFERENCE 50.000 Hz

206 RAMP TYPE Ramp type [0] LINEAR207 RAMP UP TYPE 1 Ramp-up time 1 1.00 sec

208 RAMP DOWN TIME 1 Ramp-down time 1 0.50 sec209 RAMP UP TYPE 2 Ramp-up time 2 0.02 sec

210 RAMP DOWN TIME 2 Ramp-down time 2 0.02 sec211 JOG RAMP TIME Jog ramp time 3.00 sec

212 Q STOP RAMP TIME Quick stop ramp-down time 3.00 sec213 JOG FREQUENCY Jog frequency 10.0 Hz

214 REF FUNCTION Reference function [0] SUM215 PRESET REF. 1 Preset reference 1 0.00%

216 PRESET REF. 2 Preset reference 2 0.00%217 PRESET REF. 3 Preset reference 3 0.00%

218 PRESET REF. 4 Preset reference 4 0.00%219 CATCH UP/SLW DWN Catch up/slow down reference 0.00%221 CURRENT LIMIT 160%223 WARN. CURRENT LO 0.0 A

224 WARN. CURRENT HI 2.8 A225 WARN. FREQ. LOW 0.0 Hz

226 WARN. FREQ. HIGH 132.0 Hz227 WARN. FEEDB. LOW -4000.000%

228 WARN. FEEDB HIGH 4000.000%229 FREQ BYPASS B.W. Frequency bypass, bandwidth 0 Hz (OFF)

230 FREQ. BYPASS 1 Frequency bypass 1 0.0 Hz231 FREQ. BYPASS 2 Frequency bypass 2 0.0 Hz

Inputs and outputs302 DIGITAL INPUT 18 Terminal 18, input [0] NO OPERATION

303 DIGITAL INPUT 19 Terminal 19, input [0] NO OPERATION

304 DIGITAL INPUT 27 Terminal 27, input [0] NO OPERATION

305 DIGITAL INPUT 29 Terminal 29, input [0] NO OPERATION

307 DIGITAL INPUT 33 Terminal 33, input [0] NO OPERATION

308 AI [V] 53 FUNCT. Terminal 53, analogue input voltage [1] REFERENCE

309 AI 53 SCALE LOW Terminal 53, min. scaling 0.0 Volt

310 AI 53 SCALE HIGH Terminal 53, max. scaling 10.0 Volt

314 AI [MA] 60 FUNCT. Terminal 60, analogue input current [0] NO OPERATION

315 AI 60 SCALE LOW Terminal 60, min. scaling 0.0 mA

316 AI 60 SCALE HIGH Terminal 604, max. scaling 20.0 mA

317 LIVE ZERO TIME 0 Time out 10 sec

318 LIVE ZERO FUNCT. Function after time out [0] OFF

319 AO 42 FUNCT. Analogue output terminal 42 [7] 0 - IMAX = 0 - 20 mA

323 RELAY 1-3 FUNCT. Relay output 1-3 [0] NO OPERATION

327 PULSE MAX 33 Pulse Max. 33 5000 Hz

328 PULSE MAX 29 Pulse Max. 29 5000 Hz

341 DO 46 FUNCTION Digital output terminal 46 [1] UNIT READY

342 DO 46 MAX. PULS Terminal 46, max. pulse scaling 5000 Hz

343 PRECISE STOP Precise stop function [0] NORMAL

344 PULSE COUNT PRE Counter value 100000 pulses

349 SPEED COMP DELAY Speed comp delay OFF

Special functions400 BRAKE FUNCTION Brake function [0] OFF

405 RESET MODE Reset function [0] MANUAL RESET

406 AUTORESTART TIME Automatic restart time 5 sec

Output frequency low limit (FMIN)

Output frequency high limit (FMAX)

Minimum reference, RefMIN

Maximum reference, RefMAX

Current limit. ILIM

Warning: Low current, ILOW

Warning: High current, IHIGH

Warning: Low frequency, fLOW

Warning: High frequency, fHIGH

Warning: Low feedback, FBLOW

Warning: High feedback, FBHIGH

Page 3: Danfos - Fcd 300 Config

409 TRIP DELAY CUR. OFF (61 sec.)

411 SWITCH FREQ. Switching frequency 4.5 kHz

413 OVERMODULLATION Overmodulation function [1] ON

414 MIN. FEEDBACK 0.000

415 MAX. FEEDBACK 1500.000

416 REF/FEEDB. UNIT Process units [0] NO UNIT

445 FLYING START Flying start [0] DISABLE

456 BRAKE VOL REDUCE Brake voltage reduce 0

Serial communication500 BUS ADDRESS Address 1

501 BAUDRATE Baudrate [5] 9600 BAUD

502 COASTING SELECT Coasting [3] LOGIC OR

503 Q STOP SELECT Quick-stop [3] LOGIC OR

504 DC BRAKE SELECT DC-brake [3] LOGIC OR

505 START SELECT Start [3] LOGIC OR

506 REVERSING SELECT Reversing [3] LOGIC OR

507 SETUP SELECT Selection of Setup [3] LOGIC OR

508 PRES.REF. SELECT Selection of speed [0] DIGITAL INPUT

509 BUS JOG 1 FREQ. Bus jog 1 10.0 Hz

510 BUS JOG 2 FREQ. Bus jog 2 10.0 Hz

512 TELEGRAM PROFILE Telegram profile FC PROFILE

513 BUS TIMEOUT TIME Bus time interval 1 sec

514 BUS TIMEOUT FUNC Bus time interval function [0] OFF

535 BUS FEEDBACK 1 0

Technical functions600 OPERATING HOURS Operating hours 444.6 h

601 RUNNING HOURS Hours run 229.8 h

602 KWH COUNTER kWh counter 31.2 kWh

603 POWER UP's No. of cut-ins 64

604 OVER TEMP's No. of overtemps 0

605 OVER VOLTS No. of overvoltages 0

615 F.LOG: ERROR COD Fault log : Error code [1] 0

616 F.LOG: TIME Fault log : Time [1] 0

617 F.LOG: VALUE Fault log : Value [1] 0

618 RESET KWH COUNT Reset of kWh counter [0] DO NOT RESET

619 RESET RUN. HOUR Reset of hours-run counter [0] DO NOT RESET

620 OPERATION MODE Operating mode [0] NORMAL OPERATION

621 VLT TYPE VLT Type FCD 311 380 V - 480 V

624 SOFTWARE VERSION Software version number V 1.44 / 2.00

625 LCP ID NO LCP identification number ID 2.00 2 Kb

626 PARAM DB ID Database identification number ID 1.07

627 POWER UNIT DB ID Power section identification number ID 1.50

628 APP. OPTION Application option type NONE

630 COM. OPTION Communication option type DEVICENET

632 BMC software identification ID 2.06

634 Unit identification for communication ID 007.099.176

635 Software parts no. NOT USED

640 Software version 1.44

641 BMC software identification 2.06

642 Power card identification 1.5

643 UPDATE VLT NO

645 COMM OPTION SW 0.00

646 APPL OPTION SW 0.00

678 Configure Control Card CANBUS

800 PROTOCOL SELECT Protocol select [2] DEVICENET

801 BAUD RATE SELECT Baud rate select [20] 125 KBAUD

803 BUS TIME OUT Bus time out 10 s

804 TIME OUT FUNCT. Bus time out function [2] STOP

805 BIT 10 FUNCTION Bit 10 function BIT 10 = 1 > CTW ACT

Trip delay overcurrent. ILIM

Minimum feedback, FBMIN

Maximum feedback, FBMAX

Page 4: Danfos - Fcd 300 Config

832 BUS OFF INT. BEH. Bus Off Interrupt Behavior [0] HOLD CAN

833 FIELDBUS ENABLE Fieldbus enable [1] ENABLE

834 COS FILTER 1 Filter Mask for status word FFFF hex

835 COS FILTER 2 Filter Mask for main actual value FFFF hex

836 COS FILTER 3 Filter Mask PCD 1 FFFF hex

837 COS FILTER 4 Filter Mask PCD 2 FFFF hex

838 EDS DATA TYPES EDS Data Types [1] ERRATA 2

850 TRANSMIT ERROR C Readout Transmit Error Counter 000000000

851 RECEIVE ERROR C Readout Receive Error Counter 000000000

852 BUS OFF ERROR C Readout Bus Off Counter 000000000

904 PPO TYPE SELECT PPO Selection [13] INSTANCE 101 / 151

915 PCD CONFIG WRITE PCD write configuration [1] 000

916 PCD CONFIG READ PCD read configuration [1] 528

918 STATION ADDRESS Station address/MAC ID 006

970 EDIT SETUP SELECT Parameter setup selection [5] ACTIVE SETUP

971 STORE DATA VALUE Save data values [0] OFF

980 DEFINED PARAM. 1 Defined parameter 1 [1] 001

981 DEFINED PARAM. 2 Defined parameter 2 [1] 415

982 DEFINED PARAM. 3 Defined parameter 3 [1] 904

990 MODIFI. PARAM. 1 Modified parameter 1 [1] 003

991 MODIFI. PARAM. 2 Modified parameter 2 [1] 000

992 MODIFI. PARAM. 3 Modified parameter 3 [1] 000

Page 5: Danfos - Fcd 300 Config

DANFOSS - FCD 300 Configuration for Conveyor M6 / Beer Filler

Note (Setting range)Operation and Display

Remote control

Value : 0.01 - 100.00

Remote-operated control as parameter 100

Active

Not active

Not active

Active

Forced stop, use saved ref.

Not active

Value : [index 1 - 20] Value : 0 - 999

Overload

Load and motorSpeed control, open loop

Constant torque

Value : 0.18 - 4 kW

Value : 50 - 999 V

Value : 24 - 1000 Hz

Optimisation off

Value : 0.000 - x.xxx Ohm

Value : 0.00 - x.xx Ohm

Value : 0 - 100 %

Value : 0.0 - 0.5 sec.

Value : 0.0 - 10.0 sec.

Coasting during start delay time

Coasting

Value : 0.1 - 10 Hz

Value : 0 - 60 sec.

Value : 0.0 (OFF) - parameter 202

ETR trip 1

Value : 0.0 - 10.0 Hz

Value : 0.0 - 200.0 V

Value : 0 - 100 % of max. DC brake voltage

Value : 0.0 - 100.00 V

Value : 0.0 - 300.0 %

Value : 0.00 - 20.00 V/Hz

Value : -500 - +500% of rated slip compensation

Value : 0 - 100% of max. DC hold voltage

Value : 0.5 - 132.0/1000.0 Hz

Value : 0.5 - 132.0/1000.0 Hz

Value : 0 % of Inom - 100 % of Inom

Value : 0.000 - xxx,xxx Ohm

Value : 0.01 - IMAX

Value : 100 - fM,N x 60 (max. 60000 rpm)

Page 6: Danfos - Fcd 300 Config

Value : 1.00 - 1.50

Off

References and limitsOnly clockwise, 0-132 Hz

Value : Min. reference - Max. reference

Linear

Value : 0.02 - 3600.00 sec.

Value : 0.02 - 3600.00 sec.

Value : 0.02 - 3600.00 sec.

Value : 0.02 - 3600.00 sec.

Value : 0.02 - 3600.00 sec.

Value : 0.02 - 3600.00 sec.

Value : 0.0 - par. 202

Value : -100.00 % - +100.00 %

Value : -100.00 % - +100.00 %

Value : -100.00 % - +100.00 %

Value : -100.00 % - +100.00 %

Value : 0.00 - 100 % of the given reference

Value : 0 - xxx.x % of par. 105

Value : 0.0 - par. 224

Value : 0.0 - par. 226

Value : par. 225 - 132 Hz

Value : -100,000.000 - par. 228

Value : par. 227 - 100,000.000

Value : 0 (OFF) - 100 Hz

Value : 0 - 1000 Hz

Value : 0 - 1000 Hz

Inputs and outputsNo function

No function

No function

No function

No function

Reference

Value : 0.0 - 10.0 Volt

Value : 0.0 - 10.0 Volt

No function

Value : 0.0 - 20.0 mA

Value : 0.0 - 20.0 mA

Value : 0 - 99 sec.

No operation

No function

Value : 150 - 67600 Hz

Value : 150 - 67600 Hz

Drive ready

Value : 150 - 10000 Hz

Normal ramp stop

Value : 1 - 999999

Value : 0 ms - 100 ms

Special functionsOff

Manual reset

Value : 0 - 10 sec.

Value : 0.0 - fMAX

Value : fMIN - 132/1000 Hz (parameter 200)

Value : -100,000.000 - par. 205 RefMAX

Value : par. 204 ReMIN - 100,000.000

Value : par. 223 - IMAX

Output current 0 - IMAX 0 - 20 mA

Page 7: Danfos - Fcd 300 Config

Value : 0 - 60 sec. (61 = OFF)

Value : 3000 - 14000 Hz

Off

Value : 0 - 50 V

Serial communicationValue : 1 - 126

9600 Baud

Logic or

Logic or

Logic or

Logic or

Digital input

Logic or

Logic or

Value : 0.0 - nparameter 202

Value : 0.0 - nparameter 202

Value : 1 - 99 sec.

Off

Technical functionsRange : 0 - 130,000.0

Range : 0 - 130,000.0

Range : 0 - 9999

Range : 0 - 9999

Range : 0 - 9999

Range : 0 - 9999

Value : [Index 1 - 10] Error code 0 - 44

Value : [Index 1 - 10]

Value : [Index 1 - 10]

No reset

No reset

Normal Operation

Devicenet

125 kbps

Value : 1 - 99 sec.

Stop with auto restart

This parameter is read only

Value : -100,000.000 - Par. 415 FBMAX

Value : Par. 414 FBMIN - 100,000.000

Page 8: Danfos - Fcd 300 Config

Ho;d the device in bus-off state

Value : 0000 - FFFF Hex

Value : 0000 - FFFF Hex

Value : 0000 - FFFF Hex

Value : 0000 - FFFF Hex

Errata 2

Value : 0 - 63

Active set up

Not active

Read only

Read only

Read only

Read only

Read only

Read only

Value : Sub index 1 (PCD 1) [Par. Number] Sub index 2 (PCD 2) [Par. Number]

Value : Sub index 1 (PCD 1) [Par. Number] Sub index 2 (PCD 2) [Par. Number]

Page 9: Danfos - Fcd 300 Config

DANFOSS - FCD 300 Configuration for Input Conveyors M1, M2, M3, M4, M5, M6 / Beer Filler

PNU # Display Text Parameter Description M1 M2 M3 M4 M5 User-set value M6KEYB. & DISPLAY

001 LANGUAGE Language [0] ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH

002 OPERATION SITE Local/Remote Operation [0] REMOTE REMOTE REMOTE REMOTE REMOTE REMOTE

003 LOCAL REFERENCE Local reference 20.000 Hz 20.000 Hz 20.000 Hz 20.000 Hz 20.000 Hz 20.000 Hz

004 ACTIVE SETUP Active Setup [1] SETUP 1 SETUP 1 SETUP 1 SETUP 1 SETUP 1 SETUP 1

005 EDIT SETUP Programming Setup [5] ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP

006 SETUP COPY Setup copying [0] NO COPY NO COPY NO COPY NO COPY NO COPY NO COPY

007 LCP COPY LCP copy [0] NO COPY NO COPY NO COPY NO COPY NO COPY NO COPY008 FREQUENCY SCALE Display scaling of output frequency 1.00 1.00 1.00 1.00 1.00 1.00

009 DISPLAY LINE 2 Large display readout [4] FREQUENCY [Hz] FREQUENCY [Hz] FREQUENCY [Hz] FREQUENCY [Hz] FREQUENCY [Hz] FREQUENCY [Hz]

010 DISPLAY LINE 1.1 Small display line 1.1 [1] REFERENCE [%] REFERENCE [%] REFERENCE [%] REFERENCE [%] REFERENCE [%] REFERENCE [%]

011 DISPLAY LINE 1.2 Small display line 1.2 [6] MOTOR CURRENT [A] MOTOR CURRENT [A] MOTOR CURRENT [A] MOTOR CURRENT [A] MOTOR CURRENT [A] MOTOR CURRENT [A]

012 DISPLAY LINE 1.3 Small display line 1.3 [8] POWER [kW] POWER [kW] POWER [kW] POWER [kW] POWER [kW] POWER [kW]

013 LOC CTRL/CONFIG. Local Control [4] LOC+DIG CTRL/AS P100 LOC+DIG CTRL/AS P100 LOC+DIG CTRL/AS P100 LOC+DIG CTRL/AS P100 LOC+DIG CTRL/AS P100 LOC+DIG CTRL/AS P100014 LOCAL STOP Local Stop [1] ENABLE ENABLE ENABLE ENABLE ENABLE ENABLE

015 LOCAL JOGGING Local Jog [0] DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE

016 LOCAL REVERSING Local reversing [0] DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE

017 LOCAL RESET Local reset of trip [1] ENABLE ENABLE ENABLE ENABLE ENABLE ENABLE

018 DATA CHANGE LOCK Lock for data change [0] NOT LOCKED NOT LOCKED NOT LOCKED NOT LOCKED NOT LOCKED NOT LOCKED

019 POWER UP ACTION Operating mode at Power-up, local operation [1] LOCAL = STOP LOCAL = STOP LOCAL = STOP LOCAL = STOP LOCAL = STOP LOCAL = STOP

020 HAND OPERATION DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE

024 USER QUICKMENU Userdefined Quick Menu [0] DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE

025 QUICK MENU SETUP Quick Menu setup [1] 000 [1] 000 [1] 000 [1] 000 [1] 000 [1] 000

026 LED STATUS LED Status [0] OVERLOAD OVERLOAD OVERLOAD OVERLOAD OVERLOAD OVERLOAD

Load and motor100 CONFIG. MODE Configuration [0] SPEED OPEN LOOP SPEED OPEN LOOP SPEED OPEN LOOP SPEED OPEN LOOP SPEED OPEN LOOP SPEED OPEN LOOP

101 TORQUE CHARACT Torque characteristics [1] CONSTANT TORQUE CONSTANT TORQUE CONSTANT TORQUE CONSTANT TORQUE CONSTANT TORQUE CONSTANT TORQUE

102 MOTOR POWER 1.10 kW 1.10 kW 1.10 kW 1.10 kW 1.10 kW 1.10 kW

103 MOTOR VOLTAGE 400 V 400 V 400 V 400 V 400 V 400 V

104 MOTOR FREQUENCY 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz

105 MOTOR CURRENT 2.80 A 2.80 A 2.80 A 2.80 A 2.80 A 2.80 A

106 MOTOR NOM. SPEED Rated Motor Speed 1420 RPM 1420 RPM 1420 RPM 1420 RPM 1420 RPM 1420 RPM

107 AUTO MOTOR TUN. Automatic motor tuning, ATM [0] AMT OFF AMT OFF AMT OFF AMT OFF AMT OFF AMT OFF

108 STATOR RESISTAN 6.000 OHM 6.000 OHM 6.000 OHM 6.000 OHM 6.000 OHM 6.000 OHM

109 STATOR REACTANCE 180.00 OHM 180.00 OHM 180.00 OHM 180.00 OHM 180.00 OHM 180.00 OHM

117 RESONANCE DAMP. Resonance dampening 0% 0% 0% 0% 0% 0%

119 HIGH START TORQ. High start torque OFF (0.0 sec) OFF (0.0 sec) OFF (0.0 sec) OFF (0.0 sec) OFF (0.0 sec) OFF (0.0 sec)

120 START DELAY Start delay 0.0 sec 0.0 sec 0.0 sec 0.0 sec 0.0 sec 0.0 sec

121 START FUNCTION Start function [2] COAST/DELAY TIME COAST/DELAY TIME COAST/DELAY TIME COAST/DELAY TIME COAST/DELAY TIME COAST/DELAY TIME

122 FUNCTION AT STOP Function at stop [0] COAST COAST COAST COAST COAST COAST

123 MIN.F. FUNC.STOP Min. frequency for activating of function at stop 0.1 Hz 0.1 Hz 0.1 Hz 0.1 Hz 0.1 Hz 0.1 Hz

126 DC BRAKING TIME DC braking time 10 sec 10 sec 10 sec 10 sec 10 sec 10 sec

127 DC BRAKE CUT-IN DC brake cut-in frequency 0.0 Hz (OFF) 0.0 Hz (OFF) 0.0 Hz (OFF) 0.0 Hz (OFF) 0.0 Hz (OFF) 0.0 Hz (OFF)

128 MOT.THERM PROTECT Thermal motor protection [4] ETR TRIP 1 ETR TRIP 1 ETR TRIP 1 ETR TRIP 1 ETR TRIP 1 ETR TRIP 1

130 START FREQUENCY Start frequency 0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz

131 INITIAL VOLTAGE Initial voltage 0.0 Volt 0.0 Volt 0.0 Volt 0.0 Volt 0.0 Volt 0.0 Volt

132 DC BRAKE VOLTAGE DC brake voltage 0 % (OFF) 0 % (OFF) 0 % (OFF) 0 % (OFF) 0 % (OFF) 0 % (OFF)

133 START VOLTAGE Start voltage 12.67 V 12.67 V 12.67 V 12.67 V 12.67 V 12.67 V

134 LOAD COMPENSATIO Load compensation 100% 100% 100% 100% 100% 100%

135 U/F RATIO U/f-ratio 7.56 7.56 7.56 7.56 7.56 7.56

136 SLIP COMP. Slip compensation 100% 100% 100% 100% 100% 100%

137 DC HOLD VOLTAGE DC hold voltage 0% 0% 0% 0% 0% 0%

Motor Power PM,N

Motor Voltage UM,N

Motor Frequency fM,N

Motor Current IM,N

Stator resistance RS

Stator reactance XS

Page 10: Danfos - Fcd 300 Config

DANFOSS - FCD 300 Configuration for Input Conveyors M1, M2, M3, M4, M5, M6 / Beer Filler

PNU # Display Text Parameter Description M1 M2 M3 M4 M5 User-set value M6138 BRAKE CUT OUT Brake cut out value 3.0 Hz 3.0 Hz 3.0 Hz 3.0 Hz 3.0 Hz 3.0 Hz

139 BRAKE CUT IN Brake cut in frequency 3.0 Hz 3.0 Hz 3.0 Hz 3.0 Hz 3.0 Hz 3.0 Hz

140 CURRENT MIN VAL Current, minimum value 10% 10% 10% 10% 10% 10%

142 LEAK. REACTANCE 18.000 OHM 18.000 OHM 18.000 OHM 18.000 OHM 18.000 OHM 18.000 OHM

144 GAIN AC BRAKE Gain AC brake 1.30 1.30 1.30 1.30 1.30 1.30

146 RESET VECTOR Reset voltage vector [0] OFF OFF OFF OFF OFF OFF

148 MOTOR TYPE GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL

References and limits200 OUT FREQ RNG/ROT Output frequency range [0] 132 Hz CLOCK WISE 132 Hz CLOCK WISE 132 Hz CLOCK WISE 132 Hz CLOCK WISE 132 Hz CLOCK WISE 132 Hz CLOCK WISE

201 MIN. OUTPUT FREQ. 0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz

202 MAX, OUTPUT FREQ. 132.0 Hz 132.0 Hz 132.0 Hz 132.0 Hz 132.0 Hz 132.0 Hz

203 REFERENCE RANGE Reference range [0] MIN - MAX MIN - MAX MIN - MAX MIN - MAX MIN - MAX MIN - MAX

204 MIN. REFERENCE 0.000 Hz 0.000 Hz 0.000 Hz 0.000 Hz 0.000 Hz 0.000 Hz205 MAX. REFERENCE 60.000 Hz 60.000 Hz 60.000 Hz 85.000 Hz 60.000 Hz 50.000 Hz

206 RAMP TYPE Ramp type [0] LINEAR LINEAR LINEAR LINEAR LINEAR LINEAR207 RAMP UP TYPE 1 Ramp-up time 1 0.02 sec 0.50 sec 1.00 sec 1.00 sec 1.00 sec 1.00 sec

208 RAMP DOWN TIME 1 Ramp-down time 1 0.02 sec 0.50 sec 1.00 sec 1.00 sec 1.00 sec 0.50 sec209 RAMP UP TYPE 2 Ramp-up time 2 0.02 sec 0.02 sec 0.02 sec 0.02 sec 0.02 sec 0.02 sec

210 RAMP DOWN TIME 2 Ramp-down time 2 0.02 sec 0.02 sec 0.02 sec 0.02 sec 0.02 sec 0.02 sec211 JOG RAMP TIME Jog ramp time 3.00 sec 3.00 sec 3.00 sec 3.00 sec 3.00 sec 3.00 sec

212 Q STOP RAMP TIME Quick stop ramp-down time 3.00 sec 3.00 sec 3.00 sec 3.00 sec 3.00 sec 3.00 sec213 JOG FREQUENCY Jog frequency 10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz

214 REF FUNCTION Reference function [0] SUM SUM SUM SUM SUM SUM215 PRESET REF. 1 Preset reference 1 0.00% 0.00% 0.00% 0.00% 0.00% 0.00%

216 PRESET REF. 2 Preset reference 2 0.00% 0.00% 0.00% 0.00% 0.00% 0.00%217 PRESET REF. 3 Preset reference 3 0.00% 0.00% 0.00% 0.00% 0.00% 0.00%

218 PRESET REF. 4 Preset reference 4 0.00% 0.00% 0.00% 0.00% 0.00% 0.00%219 CATCH UP/SLW DWN Catch up/slow down reference 0.00% 0.00% 0.00% 0.00% 0.00% 0.00%221 CURRENT LIMIT 160.0% 160.0% 160.0% 160.0% 160.0% 160.0%223 WARN. CURRENT LO 0.0 A 0.0 A 0.0 A 0.0 A 0.0 A 0.0 A

224 WARN. CURRENT HI 2.8 A 2.8 A 2.8 A 2.8 A 2.8 A 2.8 A225 WARN. FREQ. LOW 0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz

226 WARN. FREQ. HIGH 132.0 Hz 132.0 Hz 132.0 Hz 132.0 Hz 132.0 Hz 132.0 Hz227 WARN. FEEDB. LOW -4000.000% -4000.000% -4000.000% -4000.000% -4000.000% -4000.000%

228 WARN. FEEDB HIGH 4000.000% 4000.000% 4000.000% 4000.000% 4000.000% 4000.000%229 FREQ BYPASS B.W. Frequency bypass, bandwidth OFF OFF OFF OFF OFF OFF

230 FREQ. BYPASS 1 Frequency bypass 1 OFF OFF OFF OFF OFF OFF231 FREQ. BYPASS 2 Frequency bypass 2 OFF OFF OFF OFF OFF OFF

Inputs and outputs302 DIGITAL INPUT 18 Terminal 18, input [0] NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION

303 DIGITAL INPUT 19 Terminal 19, input [0] NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION

304 DIGITAL INPUT 27 Terminal 27, input [0] NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION

305 DIGITAL INPUT 29 Terminal 29, input [0] NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION

307 DIGITAL INPUT 33 Terminal 33, input [0] NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION

308 AI [V] 53 FUNCT. Terminal 53, analogue input voltage [1] REFERENCE REFERENCE REFERENCE REFERENCE REFERENCE REFERENCE

309 AI 53 SCALE LOW Terminal 53, min. scaling 0.0 Volt 0.0 Volt 0.0 Volt 0.0 Volt 0.0 Volt 0.0 Volt

310 AI 53 SCALE HIGH Terminal 53, max. scaling 10.0 Volt 10.0 Volt 10.0 Volt 10.0 Volt 10.0 Volt 10.0 Volt

314 AI [MA] 60 FUNCT. Terminal 60, analogue input current [0] NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION

315 AI 60 SCALE LOW Terminal 60, min. scaling 0.0 mA 0.0 mA 0.0 mA 0.0 mA 0.0 mA 0.0 mA

316 AI 60 SCALE HIGH Terminal 604, max. scaling 20.0 mA 20.0 mA 20.0 mA 20.0 mA 20.0 mA 20.0 mA

317 LIVE ZERO TIME 0 Time out 10 sec 10 sec 10 sec 10 sec 10 sec 10 sec

318 LIVE ZERO FUNCT. Function after time out [0] OFF OFF OFF OFF OFF OFF

319 AO 42 FUNCT. Analogue output terminal 42 [7] 0 - IMAX = 0 - 20 mA 0 - IMAX = 0 - 20 mA 0 - IMAX = 0 - 20 mA 0 - IMAX = 0 - 20 mA 0 - IMAX = 0 - 20 mA 0 - IMAX = 0 - 20 mA

Leakage reactance XL

Output frequency low limit (FMIN)

Output frequency high limit (FMAX)

Minimum reference, RefMIN

Maximum reference, RefMAX

Current limit. ILIM

Warning: Low current, ILOW

Warning: High current, IHIGH

Warning: Low frequency, fLOW

Warning: High frequency, fHIGH

Warning: Low feedback, FBLOW

Warning: High feedback, FBHIGH

Page 11: Danfos - Fcd 300 Config

DANFOSS - FCD 300 Configuration for Input Conveyors M1, M2, M3, M4, M5, M6 / Beer Filler

PNU # Display Text Parameter Description M1 M2 M3 M4 M5 User-set value M6323 RELAY 1-3 FUNCT. Relay output 1-3 [0] NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION

327 PULSE MAX 33 Pulse Max. 33 5000 Hz 5000 Hz 5000 Hz 5000 Hz 5000 Hz 5000 Hz

328 PULSE MAX 29 Pulse Max. 29 5000 Hz 5000 Hz 5000 Hz 5000 Hz 5000 Hz 5000 Hz

341 DO 46 FUNCTION Digital output terminal 46 [1] NO OPERATION NO OPERATION NO OPERATION NO OPERATION NO OPERATION UNIT READY

342 DO 46 MAX. PULS Terminal 46, max. pulse scaling 5000 Hz 5000 Hz 5000 Hz 5000 Hz 5000 Hz 5000 Hz

343 PRECISE STOP Precise stop function [0] NORMAL NORMAL NORMAL NORMAL NORMAL NORMAL

344 PULSE COUNT PRE Counter value 100000 100000 100000 100000 100000 100000

349 SPEED COMP DELAY Speed comp delay OFF OFF OFF OFF OFF OFF

Special functions400 BRAKE FUNCTION Brake function [0] OFF OFF OFF OFF OFF OFF

405 RESET MODE Reset function [0] MANUAL RESET MANUAL RESET MANUAL RESET MANUAL RESET MANUAL RESET MANUAL RESET

406 AUTORESTART TIME Automatic restart time 5 sec 5 sec 5 sec 5 sec 5 sec 5 sec

409 TRIP DELAY CUR. OFF OFF OFF OFF OFF OFF

411 SWITCH FREQ. Switching frequency 4500 Hz 4500 Hz 4500 Hz 4500 Hz 4500 Hz 4500 Hz

413 OVERMODULLATION Overmodulation function [1] ON ON ON ON ON ON

414 MIN. FEEDBACK 0.000 0.000 0.000 0.000 0.000 0.000

415 MAX. FEEDBACK 1500.000 1500.000 1500.000 1500.000 1500.000 1500.000

416 REF/FEEDB. UNIT Process units [0] NO UNIT NO UNIT NO UNIT NO UNIT NO UNIT NO UNIT

445 FLYING START Flying start [0] DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE

456 BRAKE VOL REDUCE Brake voltage reduce 0 0 0 0 0 0

Serial communication500 BUS ADDRESS Address 1 1 1 1 1 1

501 BAUDRATE Baudrate [5] 9600 BAUD 9600 BAUD 9600 BAUD 9600 BAUD 9600 BAUD 9600 BAUD

502 COASTING SELECT Coasting [3] LOGIC OR LOGIC OR LOGIC OR LOGIC OR LOGIC OR LOGIC OR

503 Q STOP SELECT Quick-stop [3] LOGIC OR LOGIC OR LOGIC OR LOGIC OR LOGIC OR LOGIC OR

504 DC BRAKE SELECT DC-brake [3] LOGIC OR LOGIC OR LOGIC OR LOGIC OR LOGIC OR LOGIC OR

505 START SELECT Start [3] LOGIC OR LOGIC OR LOGIC OR LOGIC OR LOGIC OR LOGIC OR

506 REVERSING SELECT Reversing [3] LOGIC OR LOGIC OR LOGIC OR LOGIC OR LOGIC OR LOGIC OR

507 SETUP SELECT Selection of Setup [3] LOGIC OR LOGIC OR LOGIC OR LOGIC OR LOGIC OR LOGIC OR

508 PRES.REF. SELECT Selection of speed [0] DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT

509 BUS JOG 1 FREQ. Bus jog 1 10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz

510 BUS JOG 2 FREQ. Bus jog 2 10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz

512 TELEGRAM PROFILE Telegram profile FC PROFILE FC PROFILE FC PROFILE FC PROFILE FC PROFILE FC PROFILE

513 BUS TIMEOUT TIME Bus time interval 1 sec 1 sec 1 sec 1 sec 1 sec 1 sec

514 BUS TIMEOUT FUNC Bus time interval function [0] OFF OFF OFF OFF OFF OFF

535 BUS FEEDBACK 1 0 0 0 0 0 0

Technical functions600 OPERATING HOURS Operating hours 492.1 h 492.9 h 492.5 h 486.3 h 489.1 h 444.6 h

601 RUNNING HOURS Hours run 229.8 h 222.9 h 226.5 h 227.5 h 229.7 h 229.8 h

602 KWH COUNTER kWh counter 15.9 kWh 12.0 kWh 30.6 h 74.1 kWh 31.2 kWh 31.2 kWh

603 POWER UP's No. of cut-ins 56 56 59 55 65 64

604 OVER TEMP's No. of overtemps 0 0 0 0 0 0

605 OVER VOLTS No. of overvoltages 0 0 0 0 0 0

615 F.LOG: ERROR COD Fault log : Error code [1] 0 [1] 0 [1] 13 [1] 13 [1] 13 [1] 0

616 F.LOG: TIME Fault log : Time [1] 0 [1] 0 [1] 988 [1] 1182 [1] 988 [1] 0

617 F.LOG: VALUE Fault log : Value [1] 0 [1] 0 [1] 0 [1] 0 [1] 0 [1] 0

618 RESET KWH COUNT Reset of kWh counter [0] DO NOT RESET DO NOT RESET DO NOT RESET DO NOT RESET DO NOT RESET DO NOT RESET

619 RESET RUN. HOUR Reset of hours-run counter [0] DO NOT RESET DO NOT RESET DO NOT RESET DO NOT RESET DO NOT RESET DO NOT RESET

620 OPERATION MODE Operating mode [0] NORMAL OPERATION NORMAL OPERATION NORMAL OPERATION NORMAL OPERATION NORMAL OPERATION NORMAL OPERATION

621 VLT TYPE VLT Type FCD 311 380 V - 480 V FCD 311 380 V - 480 V FCD 311 380 V - 480 V FCD 311 380 V - 480 V FCD 311 380 V - 480 V FCD 311 380 V - 480 V

624 SOFTWARE VERSION Software version number V 1.44 / 2.00 V 1.44 / 2.00 V 1.44 / 2.00 V 1.44 / 2.00 V 1.44 / 2.00 V 1.44 / 2.00

625 LCP ID NO LCP identification number ID 2.00 2 Kb ID 2.00 2 Kb ID 2.00 2 Kb ID 2.00 2 Kb ID 2.00 2 Kb ID 2.00 2 Kb

626 PARAM DB ID Database identification number ID 1.07 ID 1.07 ID 1.07 ID 1.07 ID 1.07 ID 1.07

Trip delay overcurrent. ILIM

Minimum feedback, FBMIN

Maximum feedback, FBMAX

Page 12: Danfos - Fcd 300 Config

DANFOSS - FCD 300 Configuration for Input Conveyors M1, M2, M3, M4, M5, M6 / Beer Filler

PNU # Display Text Parameter Description M1 M2 M3 M4 M5 User-set value M6627 POWER UNIT DB ID Power section identification number ID 1.50 ID 1.50 ID 1.50 ID 1.50 ID 1.50 ID 1.50

628 APP. OPTION Application option type NONE NONE NONE NONE NONE NONE

630 COM. OPTION Communication option type DEVICENET DEVICENET DEVICENET DEVICENET DEVICENET DEVICENET

632 BMC-SOFTWARE ID BMC software identification ID 2.06 ID 2.06 ID 2.06 ID 2.06 ID 2.06 ID 2.06

634 UNIT ID Unit identification for communication ID 007.099.187 ID 007.099.171 ID 007.099.173 ID 007.038.252 ID 007.099.164 ID 007.099.176

635 SW. PART NO. Software parts no. NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED

640 SOFTWARE VERSION Software version 1.44 1.44 1.44 1.44 1.44 1.44

641 BMC2 ID BMC software identification 2.06 2.06 2.06 2.06 2.06 2.06

642 POWER ID Power card identification 1.50 1.50 1.50 1.50 1.50 1.50

643 UPDATE VLT NO NO NO NO NO NO

645 COMM OPTION SW 0.00 0.00 0.00 0.00 0.00 0.00

646 APPL OPTION SW 0.00 0.00 0.00 0.00 0.00 0.00

678 CONFIG CTRL CARD Configure Control Card CANBUS CANBUS CANBUS CANBUS CANBUS CANBUS

800 PROTOCOL SELECT Protocol select [2] DEVICENET DEVICENET DEVICENET DEVICENET DEVICENET DEVICENET

801 BAUD RATE SELECT Baud rate select [20] 125 KBAUD 125 KBAUD 125 KBAUD 125 KBAUD 125 KBAUD 125 KBAUD

803 BUS TIME OUT Bus time out 10 s 10 s 10 s 10 s 10 s 10 s

804 TIME OUT FUNCT. Bus time out function [2] STOP STOP STOP STOP STOP STOP

805 BIT 10 FUNCTION Bit 10 function BIT 10 = 1 > CTW ACT BIT 10 = 1 > CTW ACT BIT 10 = 1 > CTW ACT BIT 10 = 1 > CTW ACT BIT 10 = 1 > CTW ACT BIT 10 = 1 > CTW ACT

832 BUS OFF INT. BEH. Bus Off Interrupt Behavior [0] HOLD CAN HOLD CAN HOLD CAN HOLD CAN HOLD CAN HOLD CAN

833 FIELDBUS ENABLE Fieldbus enable [1] ENABLE ENABLE ENABLE ENABLE ENABLE ENABLE

834 COS FILTER 1 Filter Mask for status word FFFF hex FFFF hex FFFF hex FFFF hex FFFF hex FFFF hex

835 COS FILTER 2 Filter Mask for main actual value FFFF hex FFFF hex FFFF hex FFFF hex FFFF hex FFFF hex

836 COS FILTER 3 Filter Mask PCD 1 FFFF hex FFFF hex FFFF hex FFFF hex FFFF hex FFFF hex

837 COS FILTER 4 Filter Mask PCD 2 FFFF hex FFFF hex FFFF hex FFFF hex FFFF hex FFFF hex

838 EDS DATA TYPES EDS Data Types [1] ERRATA 2 ERRATA 2 ERRATA 2 ERRATA 2 ERRATA 2 ERRATA 2

850 TRANSMIT ERROR C Readout Transmit Error Counter 000000000 000000000 000000000 000000000 000000000 000000000

851 RECEIVE ERROR C Readout Receive Error Counter 000000000 000000000 000000000 000000000 000000000 000000000

852 BUS OFF ERROR C Readout Bus Off Counter 000000000 000000000 000000000 000000000 000000000 000000000

904 PPO TYPE SELECT PPO Selection [13] INSTANCE 101 / 151 INSTANCE 101 / 151 INSTANCE 101 / 151 INSTANCE 101 / 151 INSTANCE 101 / 151 INSTANCE 101 / 151

915 PCD CONFIG WRITE PCD write configuration [1] 000 [1] 000 [1] 000 [1] 000 [1] 000 [1] 000

916 PCD CONFIG READ PCD read configuration [1] 528 [1] 528 [1] 528 [1] 528 [1] 528 [1] 528

918 STATION ADDRESS Station address/MAC ID 001 002 003 004 005 006

970 EDIT SETUP SELECT Parameter setup selection [5] ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP

971 STORE DATA VALUE Save data values [0] NO ACTION NO ACTION NO ACTION NO ACTION NO ACTION NO ACTION

980 DEFINED PARAM. 1 Defined parameter 1 [1] 001 [1] 001 [1] 001 [1] 001 [1] 001 [1] 001

981 DEFINED PARAM. 2 Defined parameter 2 [1] 415 [1] 415 [1] 415 [1] 415 [1] 415 [1] 415

982 DEFINED PARAM. 3 Defined parameter 3 [1] 904 [1] 904 [1] 904 [1] 904 [1] 904 [1] 904

990 MODIFI. PARAM. 1 Modified parameter 1 [1] 003 [1] 003 [1] 003 [1] 003 [1] 003 [1] 003

991 MODIFI. PARAM. 2 Modified parameter 2 [1] 000 [1] 000 [1] 000 [1] 000 [1] 000 [1] 000

992 MODIFI. PARAM. 3 Modified parameter 3 [1] 000 [1] 000 [1] 000 [1] 000 [1] 000 [1] 000

Page 13: Danfos - Fcd 300 Config

PNU # Display Text Parameter Description M8 M9 M10Operation and Display

001 LANGUAGE Language [0] ENGLISH ENGLISH ENGLISH

002 OPERATION SITE Local/Remote Operation [0] REMOTE REMOTE REMOTE

003 LOCAL REFERENCE Local reference 20.000 Hz 20.000 Hz 20.000 Hz

004 ACTIVE SETUP Active Setup [1] SETUP 1 SETUP 1 SETUP 1

005 EDIT SETUP Programming Setup [5] ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP

006 SETUP COPY Setup copying [0] NO COPY NO COPY NO COPY

007 LCP COPY LCP copy [0] NO COPY NO COPY NO COPY008 FREQUENCY SCALE Display scaling of output frequency 1.00 1.00 1.00

009 DISPLAY LINE 2 Large display readout [4] FREQUENCY [Hz] FREQUENCY [Hz] FREQUENCY [Hz]

010 DISPLAY LINE 1.1 Small display line 1.1 [1] REFERENCE [%] REFERENCE [%] REFERENCE [%]

011 DISPLAY LINE 1.2 Small display line 1.2 [6] MOTOR CURRENT [A] MOTOR CURRENT [A] MOTOR CURRENT [A]

012 DISPLAY LINE 1.3 Small display line 1.3 [8] POWER [kW] POWER [kW] POWER [kW]

013 LOC CTRL/CONFIG. Local Control [4] LOC+DIG CTRL/AS P100 LOC+DIG CTRL/AS P100 LOC+DIG CTRL/AS P100014 LOCAL STOP Local Stop [1] ENABLE ENABLE ENABLE

015 LOCAL JOGGING Local Jog [0] DISABLE DISABLE DISABLE

016 LOCAL REVERSING Local reversing [0] DISABLE DISABLE DISABLE

017 LOCAL RESET Local reset of trip [1] ENABLE ENABLE ENABLE

018 DATA CHANGE LOCK Lock for data change [0] NOT LOCKED NOT LOCKED NOT LOCKED

019 POWER UP ACTION Operating mode at Power-up, local operation [1] LOCAL = STOP LOCAL = STOP LOCAL = STOP

020 HAND OPERATION DISABLE DISABLE DISABLE

024 USER QUICKMENU Userdefined Quick Menu [0] DISABLE DISABLE DISABLE

025 QUICK MENU SETUP Quick Menu setup [1] 000 [1] 000 [1] 000

026 LED STATUS LED Status [0] OVERLOAD OVERLOAD OVERLOAD

Load and motor100 CONFIG. MODE Configuration [0] SPEED OPEN LOOP SPEED OPEN LOOP SPEED OPEN LOOP

101 TORQUE CHARACT Torque characteristics [1] CONSTANT TORQUE CONSTANT TORQUE CONSTANT TORQUE

102 MOTOR POWER 1.10 kW 1.10 kW 1.10 kW

103 MOTOR VOLTAGE 400 V 400 V 400 V

104 MOTOR FREQUENCY 50 Hz 50 Hz 50 Hz

105 MOTOR CURRENT 2.80 A 2.80 A 2.80 A

106 MOTOR NOM. SPEED Rated Motor Speed 1420 RPM 1420 RPM 1420 RPM

107 AUTO MOTOR TUN. Automatic motor tuning, ATM [0] AMT OFF AMT OFF AMT OFF

108 STATOR RESISTAN 6.000 OHM 6.000 OHM 6.000 OHM

109 STATOR REACTANCE 180.00 OHM 180.00 OHM 180.00 OHM

117 RESONANCE DAMP. Resonance dampening 0% 0% 0%

119 HIGH START TORQ. High start torque OFF (0.0 sec) OFF (0.0 sec) OFF (0.0 sec)

120 START DELAY Start delay 0.0 sec 0.0 sec 0.0 sec

121 START FUNCTION Start function [2] COAST/DELAY TIME COAST/DELAY TIME COAST/DELAY TIME

122 FUNCTION AT STOP Function at stop [0] COAST COAST COAST

123 MIN.F. FUNC.STOP Min. frequency for activating of function at stop 0.1 Hz 0.1 Hz 0.1 Hz

126 DC BRAKING TIME DC braking time 10 sec 10 sec 10 sec

127 DC BRAKE CUT-IN DC brake cut-in frequency 0.0 Hz (OFF) 0.0 Hz (OFF) 0.0 Hz (OFF)

DANFOSS - FCD 300 Configuration for Outlet Conveyors M7, M8, M9, M10 / Beer Filler

Motor Power PM,N

Motor Voltage UM,N

Motor Frequency fM,N

Motor Current IM,N

Stator resistance RS

Stator reactance XS

Page 14: Danfos - Fcd 300 Config

PNU # Display Text Parameter Description M8 M9 M10

DANFOSS - FCD 300 Configuration for Outlet Conveyors M7, M8, M9, M10 / Beer Filler

128 MOT.THERM PROTECT Thermal motor protection [4] ETR TRIP 1 ETR TRIP 1 ETR TRIP 1

130 START FREQUENCY Start frequency 0.0 Hz 0.0 Hz 0.0 Hz

131 INITIAL VOLTAGE Initial voltage 0.0 Volt 0.0 Volt 0.0 Volt

132 DC BRAKE VOLTAGE DC brake voltage 0 % (OFF) 0 % (OFF) 0 % (OFF)

133 START VOLTAGE Start voltage 12.67 V 12.67 V 12.67 V

134 LOAD COMPENSATIO Load compensation 100% 100% 100%

135 U/F RATIO U/f-ratio 7.56 7.56 7.56

136 SLIP COMP. Slip compensation 100% 100% 100%

137 DC HOLD VOLTAGE DC hold voltage 0% 0% 0%

138 BRAKE CUT OUT Brake cut out value 3.0 Hz 3.0 Hz 3.0 Hz

139 BRAKE CUT IN Brake cut in frequency 3.0 Hz 3.0 Hz 3.0 Hz

140 CURRENT MIN VAL Current, minimum value 10% 10% 10%

142 LEAK. REACTANCE 18.000 OHM 18.000 OHM 18.000 OHM

144 GAIN AC BRAKE Gain AC brake 1.30 1.30 1.30

146 RESET VECTOR Reset voltage vector [0] OFF OFF OFF

148 MOTOR TYPE GENERAL GENERAL GENERAL

References and limits200 OUT FREQ RNG/ROT Output frequency range [0] 132 Hz CLOCK WISE 132 Hz CLOCK WISE 132 Hz CLOCK WISE

201 MIN. OUTPUT FREQ. 0.0 Hz 0.0 Hz 0.0 Hz

202 MAX, OUTPUT FREQ. 132.0 Hz 132.0 Hz 132.0 Hz

203 REFERENCE RANGE Reference range [0] MIN - MAX MIN - MAX MIN - MAX

204 MIN. REFERENCE 0.000 Hz 0.000 Hz 0.000 Hz205 MAX. REFERENCE 60.000 Hz 60.000 Hz 60.000 Hz

206 RAMP TYPE Ramp type [0] LINEAR LINEAR LINEAR207 RAMP UP TYPE 1 Ramp-up time 1 3.00 sec 3.00 sec 3.00 sec

208 RAMP DOWN TIME 1 Ramp-down time 1 3.00 sec 3.00 sec 3.00 sec209 RAMP UP TYPE 2 Ramp-up time 2 3.00 sec 3.00 sec 3.00 sec

210 RAMP DOWN TIME 2 Ramp-down time 2 3.00 sec 3.00 sec 3.00 sec211 JOG RAMP TIME Jog ramp time 3.00 sec 3.00 sec 3.00 sec

212 Q STOP RAMP TIME Quick stop ramp-down time 3.00 sec 3.00 sec 3.00 sec213 JOG FREQUENCY Jog frequency 10.0 Hz 10.0 Hz 10.0 Hz

214 REF FUNCTION Reference function [0] SUM SUM SUM215 PRESET REF. 1 Preset reference 1 0.00% 0.00% 0.00%

216 PRESET REF. 2 Preset reference 2 0.00% 0.00% 0.00%217 PRESET REF. 3 Preset reference 3 0.00% 0.00% 0.00%

218 PRESET REF. 4 Preset reference 4 0.00% 0.00% 0.00%219 CATCH UP/SLW DWN Catch up/slow down reference 0.00% 0.00% 0.00%221 CURRENT LIMIT 160% 160% 160%223 WARN. CURRENT LO 0.0 A 0.0 A 0.0 A

224 WARN. CURRENT HI 2.8 A 2.8 A 2.8 A225 WARN. FREQ. LOW 0.0 Hz 0.0 Hz 0.0 Hz

226 WARN. FREQ. HIGH 132.0 Hz 132.0 Hz 132.0 Hz227 WARN. FEEDB. LOW -4000.000% -4000.000% -4000.000%

228 WARN. FEEDB HIGH 4000.000% 4000.000% 4000.000%

Leakage reactance XL

Output frequency low limit (FMIN)

Output frequency high limit (FMAX)

Minimum reference, RefMIN

Maximum reference, RefMAX

Current limit. ILIM

Warning: Low current, ILOW

Warning: High current, IHIGH

Warning: Low frequency, fLOW

Warning: High frequency, fHIGH

Warning: Low feedback, FBLOW

Warning: High feedback, FBHIGH

Page 15: Danfos - Fcd 300 Config

PNU # Display Text Parameter Description M8 M9 M10

DANFOSS - FCD 300 Configuration for Outlet Conveyors M7, M8, M9, M10 / Beer Filler

229 FREQ BYPASS B.W. Frequency bypass, bandwidth 0 Hz (OFF) 0 Hz (OFF) 0 Hz (OFF)

230 FREQ. BYPASS 1 Frequency bypass 1 0.0 Hz 0.0 Hz 0.0 Hz231 FREQ. BYPASS 2 Frequency bypass 2 0.0 Hz 0.0 Hz 0.0 Hz

Inputs and outputs302 DIGITAL INPUT 18 Terminal 18, input [0] NO OPERATION NO OPERATION NO OPERATION

303 DIGITAL INPUT 19 Terminal 19, input [0] NO OPERATION NO OPERATION NO OPERATION

304 DIGITAL INPUT 27 Terminal 27, input [0] NO OPERATION NO OPERATION NO OPERATION

305 DIGITAL INPUT 29 Terminal 29, input [0] NO OPERATION NO OPERATION NO OPERATION

307 DIGITAL INPUT 33 Terminal 33, input [0] NO OPERATION NO OPERATION NO OPERATION

308 AI [V] 53 FUNCT. Terminal 53, analogue input voltage [1] REFERENCE REFERENCE REFERENCE

309 AI 53 SCALE LOW Terminal 53, min. scaling 0.0 Volt 0.0 Volt 0.0 Volt

310 AI 53 SCALE HIGH Terminal 53, max. scaling 10.0 Volt 10.0 Volt 10.0 Volt

314 AI [MA] 60 FUNCT. Terminal 60, analogue input current [0] NO OPERATION NO OPERATION NO OPERATION

315 AI 60 SCALE LOW Terminal 60, min. scaling 0.0 mA 0.0 mA 0.0 mA

316 AI 60 SCALE HIGH Terminal 604, max. scaling 20.0 mA 20.0 mA 20.0 mA

317 LIVE ZERO TIME 0 Time out 10 sec 10 sec 10 sec

318 LIVE ZERO FUNCT. Function after time out [0] OFF OFF OFF

319 AO 42 FUNCT. Analogue output terminal 42 [7] 0 - IMAX = 0 - 20 mA 0 - IMAX = 0 - 20 mA 0 - IMAX = 0 - 20 mA

323 RELAY 1-3 FUNCT. Relay output 1-3 [0] NO OPERATION NO OPERATION NO OPERATION

327 PULSE MAX 33 Pulse Max. 33 5000 Hz 5000 Hz 5000 Hz

328 PULSE MAX 29 Pulse Max. 29 5000 Hz 5000 Hz 5000 Hz

341 DO 46 FUNCTION Digital output terminal 46 [1] NO OPERATION NO OPERATION NO OPERATION

342 DO 46 MAX. PULS Terminal 46, max. pulse scaling 5000 Hz 5000 Hz 5000 Hz

343 PRECISE STOP Precise stop function [0] NORMAL NORMAL NORMAL

344 PULSE COUNT PRE Counter value 100000 pulses 100000 pulses 100000 pulses

349 SPEED COMP DELAY Speed comp delay OFF OFF OFF

Special functions400 BRAKE FUNCTION Brake function [0] OFF OFF OFF

405 RESET MODE Reset function [0] MANUAL RESET MANUAL RESET MANUAL RESET

406 AUTORESTART TIME Automatic restart time 5 sec 5 sec 5 sec

409 TRIP DELAY CUR. OFF (61 sec.) OFF (61 sec.) OFF (61 sec.)

411 SWITCH FREQ. Switching frequency 4.5 kHz 4.5 kHz 4.5 kHz

413 OVERMODULLATION Overmodulation function [1] ON ON ON

414 MIN. FEEDBACK 0.000 0.000 0.000

415 MAX. FEEDBACK 1500.000 1500.000 1500.000

416 REF/FEEDB. UNIT Process units [0] NO UNIT NO UNIT NO UNIT

445 FLYING START Flying start [0] DISABLE DISABLE DISABLE

456 BRAKE VOL REDUCE Brake voltage reduce 0 0 0

Serial communication500 BUS ADDRESS Address 1 1 1

501 BAUDRATE Baudrate [5] 9600 BAUD 9600 BAUD 9600 BAUD

502 COASTING SELECT Coasting [3] LOGIC OR LOGIC OR LOGIC OR

503 Q STOP SELECT Quick-stop [3] LOGIC OR LOGIC OR LOGIC OR

504 DC BRAKE SELECT DC-brake [3] LOGIC OR LOGIC OR LOGIC OR

Trip delay overcurrent. ILIM

Minimum feedback, FBMIN

Maximum feedback, FBMAX

Page 16: Danfos - Fcd 300 Config

PNU # Display Text Parameter Description M8 M9 M10

DANFOSS - FCD 300 Configuration for Outlet Conveyors M7, M8, M9, M10 / Beer Filler

505 START SELECT Start [3] LOGIC OR LOGIC OR LOGIC OR

506 REVERSING SELECT Reversing [3] LOGIC OR LOGIC OR LOGIC OR

507 SETUP SELECT Selection of Setup [3] LOGIC OR LOGIC OR LOGIC OR

508 PRES.REF. SELECT Selection of speed [0] DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT

509 BUS JOG 1 FREQ. Bus jog 1 10.0 Hz 10.0 Hz 10.0 Hz

510 BUS JOG 2 FREQ. Bus jog 2 10.0 Hz 10.0 Hz 10.0 Hz

512 TELEGRAM PROFILE Telegram profile FC PROFILE FC PROFILE FC PROFILE

513 BUS TIMEOUT TIME Bus time interval 1 sec 1 sec 1 sec

514 BUS TIMEOUT FUNC Bus time interval function [0] OFF OFF OFF

535 BUS FEEDBACK 1 0 0 0

Technical functions600 OPERATING HOURS Operating hours 489.5 h 489.6 h 488.5 h

601 RUNNING HOURS Hours run 223.4 h 218.7 h 215.4 h

602 KWH COUNTER kWh counter 46.2 kWh 54.2 kWh 50.2 kWh

603 POWER UP's No. of cut-ins 63 67 69

604 OVER TEMP's No. of overtemps 0 0 0

605 OVER VOLTS No. of overvoltages 0 0 0

615 F.LOG: ERROR COD Fault log : Error code [1] 0 [1] 0 [1] 0

616 F.LOG: TIME Fault log : Time [1] 0 [1] 0 [1] 0

617 F.LOG: VALUE Fault log : Value [1] 0 [1] 0 [1] 0

618 RESET KWH COUNT Reset of kWh counter [0] DO NOT RESET DO NOT RESET DO NOT RESET

619 RESET RUN. HOUR Reset of hours-run counter [0] DO NOT RESET DO NOT RESET DO NOT RESET

620 OPERATION MODE Operating mode [0] NORMAL OPERATION NORMAL OPERATION NORMAL OPERATION

621 VLT TYPE VLT Type FCD 315 380 V - 480 V FCD 311 380 V - 480 V FCD 311 380 V - 480 V

624 SOFTWARE VERSION Software version number V 1.44 / 2.00 V 1.44 / 2.00 V 1.44 / 2.00

625 LCP ID NO LCP identification number ID 2.00 2 Kb ID 2.00 2 Kb ID 2.00 2 Kb

626 PARAM DB ID Database identification number ID 1.07 ID 1.07 ID 1.07

627 POWER UNIT DB ID Power section identification number ID 1.50 ID 1.50 ID 1.50

628 APP. OPTION Application option type NONE NONE NONE

630 COM. OPTION Communication option type DEVICENET DEVICENET DEVICENET

632 BMC software identification ID 2.06 ID 2.06 ID 2.06

634 Unit identification for communication ID 007.099.203 ID 007.099.168 ID 007.099.167

635 Software parts no. NOT USED NOT USED NOT USED

640 Software version 1.44 1.44 1.44

641 BMC software identification 2.06 2.06 2.06

642 Power card identification 1.50 1.50 1.50

643 UPDATE VLT NO NO NO

645 COMM OPTION SW 0.00 0.00 0.00

646 APPL OPTION SW 0.00 0.00 0.00

678 Configure Control Card CANBUS CANBUS CANBUS

800 PROTOCOL SELECT Protocol select [2] DEVICENET DEVICENET DEVICENET

801 BAUD RATE SELECT Baud rate select [20] 125 KBAUD 125 KBAUD 125 KBAUD

Page 17: Danfos - Fcd 300 Config

PNU # Display Text Parameter Description M8 M9 M10

DANFOSS - FCD 300 Configuration for Outlet Conveyors M7, M8, M9, M10 / Beer Filler

803 BUS TIME OUT Bus time out 10 s 10 s 10 s

804 TIME OUT FUNCT. Bus time out function [2] STOP STOP STOP

805 BIT 10 FUNCTION Bit 10 function BIT 10 = 1 > CTW ACT BIT 10 = 1 > CTW ACT BIT 10 = 1 > CTW ACT

832 BUS OFF INT. BEH. Bus Off Interrupt Behavior [0] HOLD CAN HOLD CAN HOLD CAN

833 FIELDBUS ENABLE Fieldbus enable [1] ENABLE ENABLE ENABLE

834 COS FILTER 1 Filter Mask for status word FFFF hex FFFF hex FFFF hex

835 COS FILTER 2 Filter Mask for main actual value FFFF hex FFFF hex FFFF hex

836 COS FILTER 3 Filter Mask PCD 1 FFFF hex FFFF hex FFFF hex

837 COS FILTER 4 Filter Mask PCD 2 FFFF hex FFFF hex FFFF hex

838 EDS DATA TYPES EDS Data Types [1] ERRATA 2 ERRATA 2 ERRATA 2

850 TRANSMIT ERROR C Readout Transmit Error Counter 000000000 000000000 000000000

851 RECEIVE ERROR C Readout Receive Error Counter 000000000 000000000 000000000

852 BUS OFF ERROR C Readout Bus Off Counter 000000000 000000000 000000000

904 PPO TYPE SELECT PPO Selection [13] INSTANCE 101 / 151 INSTANCE 101 / 151 INSTANCE 101 / 151

915 PCD CONFIG WRITE PCD write configuration [1] 000 [1] 000 [1] 000

916 PCD CONFIG READ PCD read configuration [1] 528 [1] 528 [1] 528

918 STATION ADDRESS Station address/MAC ID 008 009 010

970 EDIT SETUP SELECT Parameter setup selection [5] ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP

971 STORE DATA VALUE Save data values [0] NO ACTION NO ACTION NO ACTION

980 DEFINED PARAM. 1 Defined parameter 1 [1] 001 [1] 001 [1] 001

981 DEFINED PARAM. 2 Defined parameter 2 [1] 415 [1] 415 [1] 415

982 DEFINED PARAM. 3 Defined parameter 3 [1] 904 [1] 904 [1] 904

990 MODIFI. PARAM. 1 Modified parameter 1 [1] 003 [1] 003 [1] 003

991 MODIFI. PARAM. 2 Modified parameter 2 [1] 000 [1] 000 [1] 000

992 MODIFI. PARAM. 3 Modified parameter 3 [1] 000 [1] 000 [1] 000

Page 18: Danfos - Fcd 300 Config

DANFOSS - FCD 300 Configuration for Conveyor M1, M2, M3, M4, M5, M6, M8, M9, M10 / Beer Filler

PNU # Display Text Parameter Description M1Operation and Display

001 LANGUAGE Language ENGLISH

002 OPERATION SITE Local/Remote Operation REMOTE

003 LOCAL REFERENCE Local reference 20.000 Hz

004 ACTIVE SETUP Active Setup SETUP 1

005 EDIT SETUP Programming Setup ACTIVE SETUP

006 SETUP COPY Setup copying NO COPY

007 LCP COPY LCP copy NO COPY008 FREQUENCY SCALE Display scaling of output frequency 1.00

009 DISPLAY LINE 2 Large display readout FREQUENCY [Hz]

010 DISPLAY LINE 1.1 Small display line 1.1 REFERENCE [%]

011 DISPLAY LINE 1.2 Small display line 1.2 MOTOR CURRENT [A]

012 DISPLAY LINE 1.3 Small display line 1.3 POWER [kW]

013 LOC CTRL/CONFIG. Local Control LOC+DIG CTRL/AS P100014 LOCAL STOP Local Stop ENABLE

015 LOCAL JOGGING Local Jog DISABLE

016 LOCAL REVERSING Local reversing DISABLE

017 LOCAL RESET Local reset of trip ENABLE

018 DATA CHANGE LOCK Lock for data change NOT LOCKED

019 POWER UP ACTION Operating mode at Power-up, local operation LOCAL = STOP

020 HAND OPERATION DISABLE

024 USER QUICKMENU Userdefined Quick Menu DISABLE

025 QUICK MENU SETUP Quick Menu setup [1] 000

026 LED STATUS LED Status OVERLOAD

Load and motor100 CONFIG. MODE Configuration SPEED OPEN LOOP

101 TORQUE CHARACT Torque characteristics CONSTANT TORQUE

102 MOTOR POWER 1.10 kW

103 MOTOR VOLTAGE 400 V

104 MOTOR FREQUENCY 50 Hz

105 MOTOR CURRENT 2.80 A

106 MOTOR NOM. SPEED Rated Motor Speed 1420 RPM

107 AUTO MOTOR TUN. Automatic motor tuning, ATM AMT OFF

108 STATOR RESISTAN 6.000 OHM

109 STATOR REACTANCE 180.00 OHM

117 RESONANCE DAMP. Resonance dampening 0%

119 HIGH START TORQ. High start torque OFF (0.0 sec)

120 START DELAY Start delay 0.0 sec

121 START FUNCTION Start function COAST/DELAY TIME

122 FUNCTION AT STOP Function at stop COAST

123 MIN.F. FUNC.STOP Min. frequency for activating of function at stop 0.1 Hz

126 DC BRAKING TIME DC braking time 10 sec

127 DC BRAKE CUT-IN DC brake cut-in frequency 0.0 Hz (OFF)

128 MOT.THERM PROTECT Thermal motor protection ETR TRIP 1

130 START FREQUENCY Start frequency 0.0 Hz

131 INITIAL VOLTAGE Initial voltage 0.0 Volt

132 DC BRAKE VOLTAGE DC brake voltage 0 % (OFF)

133 START VOLTAGE Start voltage 12.67 V

134 LOAD COMPENSATIO Load compensation 100%

135 U/F RATIO U/f-ratio 7.56

136 SLIP COMP. Slip compensation 100%

137 DC HOLD VOLTAGE DC hold voltage 0%

138 BRAKE CUT OUT Brake cut out value 3.0 Hz

139 BRAKE CUT IN Brake cut in frequency 3.0 Hz

140 CURRENT MIN VAL Current, minimum value 10%

142 LEAK. REACTANCE 18.000 OHM

Motor Power PM,N

Motor Voltage UM,N

Motor Frequency fM,N

Motor Current IM,N

Stator resistance RS

Stator reactance XS

Leakage reactance XL

Page 19: Danfos - Fcd 300 Config

144 GAIN AC BRAKE Gain AC brake 1.30

146 RESET VECTOR Reset voltage vector OFF

148 MOTOR TYPE GENERAL

References and limits200 OUT FREQ RNG/ROT Output frequency range 132 Hz CLOCK WISE

201 MIN. OUTPUT FREQ. 0.0 Hz

202 MAX, OUTPUT FREQ. 132.0 Hz

203 REFERENCE RANGE Reference range MIN - MAX

204 MIN. REFERENCE 0.000 Hz205 MAX. REFERENCE 60.000 Hz

206 RAMP TYPE Ramp type LINEAR207 RAMP UP TYPE 1 Ramp-up time 1 0.02 sec

208 RAMP DOWN TIME 1 Ramp-down time 1 0.02 sec209 RAMP UP TYPE 2 Ramp-up time 2 0.02 sec

210 RAMP DOWN TIME 2 Ramp-down time 2 0.02 sec211 JOG RAMP TIME Jog ramp time 3.00 sec

212 Q STOP RAMP TIME Quick stop ramp-down time 3.00 sec213 JOG FREQUENCY Jog frequency 10.0 Hz

214 REF FUNCTION Reference function SUM215 PRESET REF. 1 Preset reference 1 0.00%

216 PRESET REF. 2 Preset reference 2 0.00%217 PRESET REF. 3 Preset reference 3 0.00%

218 PRESET REF. 4 Preset reference 4 0.00%219 CATCH UP/SLW DWN Catch up/slow down reference 0.00%221 CURRENT LIMIT 160.0%223 WARN. CURRENT LO 0.0 A

224 WARN. CURRENT HI 2.8 A225 WARN. FREQ. LOW 0.0 Hz

226 WARN. FREQ. HIGH 132.0 Hz227 WARN. FEEDB. LOW -4000.000%

228 WARN. FEEDB HIGH 4000.000%229 FREQ BYPASS B.W. Frequency bypass, bandwidth OFF

230 FREQ. BYPASS 1 Frequency bypass 1 OFF231 FREQ. BYPASS 2 Frequency bypass 2 OFF

Inputs and outputs302 DIGITAL INPUT 18 Terminal 18, input NO OPERATION

303 DIGITAL INPUT 19 Terminal 19, input NO OPERATION

304 DIGITAL INPUT 27 Terminal 27, input NO OPERATION

305 DIGITAL INPUT 29 Terminal 29, input NO OPERATION

307 DIGITAL INPUT 33 Terminal 33, input NO OPERATION

308 AI [V] 53 FUNCT. Terminal 53, analogue input voltage REFERENCE

309 AI 53 SCALE LOW Terminal 53, min. scaling 0.0 Volt

310 AI 53 SCALE HIGH Terminal 53, max. scaling 10.0 Volt

314 AI [MA] 60 FUNCT. Terminal 60, analogue input current NO OPERATION

315 AI 60 SCALE LOW Terminal 60, min. scaling 0.0 mA

316 AI 60 SCALE HIGH Terminal 604, max. scaling 20.0 mA

317 LIVE ZERO TIME 0 Time out 10 sec

318 LIVE ZERO FUNCT. Function after time out OFF

319 AO 42 FUNCT. Analogue output terminal 42 0 - IMAX = 0 - 20 mA

323 RELAY 1-3 FUNCT. Relay output 1-3 NO OPERATION

327 PULSE MAX 33 Pulse Max. 33 5000 Hz

328 PULSE MAX 29 Pulse Max. 29 5000 Hz

341 DO 46 FUNCTION Digital output terminal 46 NO OPERATION

342 DO 46 MAX. PULS Terminal 46, max. pulse scaling 5000 Hz

343 PRECISE STOP Precise stop function NORMAL

344 PULSE COUNT PRE Counter value 100000

349 SPEED COMP DELAY Speed comp delay OFF

Special functions400 BRAKE FUNCTION Brake function OFF

405 RESET MODE Reset function MANUAL RESET

406 AUTORESTART TIME Automatic restart time 5 sec

Output frequency low limit (FMIN)

Output frequency high limit (FMAX)

Minimum reference, RefMIN

Maximum reference, RefMAX

Current limit. ILIM

Warning: Low current, ILOW

Warning: High current, IHIGH

Warning: Low frequency, fLOW

Warning: High frequency, fHIGH

Warning: Low feedback, FBLOW

Warning: High feedback, FBHIGH

Page 20: Danfos - Fcd 300 Config

409 TRIP DELAY CUR. OFF

411 SWITCH FREQ. Switching frequency 4500 Hz

413 OVERMODULLATION Overmodulation function ON

414 MIN. FEEDBACK 0.000

415 MAX. FEEDBACK 1500.000

416 REF/FEEDB. UNIT Process units NO UNIT

445 FLYING START Flying start DISABLE

456 BRAKE VOL REDUCE Brake voltage reduce 0

Serial communication500 BUS ADDRESS Address 1

501 BAUDRATE Baudrate 9600 BAUD

502 COASTING SELECT Coasting LOGIC OR

503 Q STOP SELECT Quick-stop LOGIC OR

504 DC BRAKE SELECT DC-brake LOGIC OR

505 START SELECT Start LOGIC OR

506 REVERSING SELECT Reversing LOGIC OR

507 SETUP SELECT Selection of Setup LOGIC OR

508 PRES.REF. SELECT Selection of speed DIGITAL INPUT

509 BUS JOG 1 FREQ. Bus jog 1 10.0 Hz

510 BUS JOG 2 FREQ. Bus jog 2 10.0 Hz

512 TELEGRAM PROFILE Telegram profile FC PROFILE

513 BUS TIMEOUT TIME Bus time interval 1 sec

514 BUS TIMEOUT FUNC Bus time interval function OFF

535 BUS FEEDBACK 1 0

Technical functions600 OPERATING HOURS Operating hours 492.1 h

601 RUNNING HOURS Hours run 229.8 h

602 KWH COUNTER kWh counter 15.9 kWh

603 POWER UP's No. of cut-ins 56

604 OVER TEMP's No. of overtemps 0

605 OVER VOLTS No. of overvoltages 0

615 F.LOG: ERROR COD Fault log : Error code [1] 0

616 F.LOG: TIME Fault log : Time [1] 0

617 F.LOG: VALUE Fault log : Value [1] 0

618 RESET KWH COUNT Reset of kWh counter DO NOT RESET

619 RESET RUN. HOUR Reset of hours-run counter DO NOT RESET

620 OPERATION MODE Operating mode NORMAL OPERATION

621 VLT TYPE VLT Type FCD 311 380 V - 480 V

624 SOFTWARE VERSION Software version number V 1.44 / 2.00

625 LCP ID NO LCP identification number ID 2.00 2 Kb

626 PARAM DB ID Database identification number ID 1.07

627 POWER UNIT DB ID Power section identification number ID 1.50

628 APP. OPTION Application option type NONE

630 COM. OPTION Communication option type DEVICENET

632 BMC-SOFTWARE ID BMC software identification ID 2.06

634 UNIT ID Unit identification for communication ID 007.099.187

635 SW. PART NO. Software parts no. NOT USED

640 SOFTWARE VERSION Software version 1.44

641 BMC2 ID BMC software identification 2.06

642 POWER ID Power card identification 1.50

643 UPDATE VLT NO

645 COMM OPTION SW 0.00

646 APPL OPTION SW 0.00

678 CONFIG CTRL CARD Configure Control Card CANBUS

800 PROTOCOL SELECT Protocol select DEVICENET

801 BAUD RATE SELECT Baud rate select 125 KBAUD

803 BUS TIME OUT Bus time out 10 s

804 TIME OUT FUNCT. Bus time out function STOP

805 BIT 10 FUNCTION Bit 10 function BIT 10 = 1 > CTW ACT

Trip delay overcurrent. ILIM

Minimum feedback, FBMIN

Maximum feedback, FBMAX

Page 21: Danfos - Fcd 300 Config

832 BUS OFF INT. BEH. Bus Off Interrupt Behavior HOLD CAN

833 FIELDBUS ENABLE Fieldbus enable ENABLE

834 COS FILTER 1 Filter Mask for status word FFFF hex

835 COS FILTER 2 Filter Mask for main actual value FFFF hex

836 COS FILTER 3 Filter Mask PCD 1 FFFF hex

837 COS FILTER 4 Filter Mask PCD 2 FFFF hex

838 EDS DATA TYPES EDS Data Types ERRATA 2

850 TRANSMIT ERROR C Readout Transmit Error Counter 000000000

851 RECEIVE ERROR C Readout Receive Error Counter 000000000

852 BUS OFF ERROR C Readout Bus Off Counter 000000000

904 PPO TYPE SELECT PPO Selection INSTANCE 101 / 151

915 PCD CONFIG WRITE PCD write configuration [1] 000

916 PCD CONFIG READ PCD read configuration [1] 528

918 STATION ADDRESS Station address/MAC ID 001

970 EDIT SETUP SELECT Parameter setup selection ACTIVE SETUP

971 STORE DATA VALUE Save data values NO ACTION

980 DEFINED PARAM. 1 Defined parameter 1 [1] 001

981 DEFINED PARAM. 2 Defined parameter 2 [1] 415

982 DEFINED PARAM. 3 Defined parameter 3 [1] 904

990 MODIFI. PARAM. 1 Modified parameter 1 [1] 003

991 MODIFI. PARAM. 2 Modified parameter 2 [1] 000

992 MODIFI. PARAM. 3 Modified parameter 3 [1] 000

Page 22: Danfos - Fcd 300 Config

DANFOSS - FCD 300 Configuration for Conveyor M1, M2, M3, M4, M5, M6, M8, M9, M10 / Beer Filler

M2 M3 M4 M5Operation and Display

ENGLISH ENGLISH ENGLISH ENGLISH

REMOTE REMOTE REMOTE REMOTE

20.000 Hz 20.000 Hz 20.000 Hz 20.000 Hz

SETUP 1 SETUP 1 SETUP 1 SETUP 1

ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP

NO COPY NO COPY NO COPY NO COPY

NO COPY NO COPY NO COPY NO COPY1.00 1.00 1.00 1.00

FREQUENCY [Hz] FREQUENCY [Hz] FREQUENCY [Hz] FREQUENCY [Hz]

REFERENCE [%] REFERENCE [%] REFERENCE [%] REFERENCE [%]

MOTOR CURRENT [A] MOTOR CURRENT [A] MOTOR CURRENT [A] MOTOR CURRENT [A]

POWER [kW] POWER [kW] POWER [kW] POWER [kW]

LOC+DIG CTRL/AS P100 LOC+DIG CTRL/AS P100 LOC+DIG CTRL/AS P100 LOC+DIG CTRL/AS P100ENABLE ENABLE ENABLE ENABLE

DISABLE DISABLE DISABLE DISABLE

DISABLE DISABLE DISABLE DISABLE

ENABLE ENABLE ENABLE ENABLE

NOT LOCKED NOT LOCKED NOT LOCKED NOT LOCKED

LOCAL = STOP LOCAL = STOP LOCAL = STOP LOCAL = STOP

DISABLE DISABLE DISABLE DISABLE

DISABLE DISABLE DISABLE DISABLE

[1] 000 [1] 000 [1] 000 [1] 000

OVERLOAD OVERLOAD OVERLOAD OVERLOAD

Load and motorSPEED OPEN LOOP SPEED OPEN LOOP SPEED OPEN LOOP SPEED OPEN LOOP

CONSTANT TORQUE CONSTANT TORQUE CONSTANT TORQUE CONSTANT TORQUE

1.10 kW 1.10 kW 1.10 kW 1.10 kW

400 V 400 V 400 V 400 V

50 Hz 50 Hz 50 Hz 50 Hz

2.80 A 2.80 A 2.80 A 2.80 A

1420 RPM 1420 RPM 1420 RPM 1420 RPM

AMT OFF AMT OFF AMT OFF AMT OFF

6.000 OHM 6.000 OHM 6.000 OHM 6.000 OHM

180.00 OHM 180.00 OHM 180.00 OHM 180.00 OHM

0% 0% 0% 0%

OFF (0.0 sec) OFF (0.0 sec) OFF (0.0 sec) OFF (0.0 sec)

0.0 sec 0.0 sec 0.0 sec 0.0 sec

COAST/DELAY TIME COAST/DELAY TIME COAST/DELAY TIME COAST/DELAY TIME

COAST COAST COAST COAST

0.1 Hz 0.1 Hz 0.1 Hz 0.1 Hz

10 sec 10 sec 10 sec 10 sec

0.0 Hz (OFF) 0.0 Hz (OFF) 0.0 Hz (OFF) 0.0 Hz (OFF)

ETR TRIP 1 ETR TRIP 1 ETR TRIP 1 ETR TRIP 1

0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz

0.0 Volt 0.0 Volt 0.0 Volt 0.0 Volt

0 % (OFF) 0 % (OFF) 0 % (OFF) 0 % (OFF)

12.67 V 12.67 V 12.67 V 12.67 V

100% 100% 100% 100%

7.56 7.56 7.56 7.56

100% 100% 100% 100%

0% 0% 0% 0%

3.0 Hz 3.0 Hz 3.0 Hz 3.0 Hz

3.0 Hz 3.0 Hz 3.0 Hz 3.0 Hz

10% 10% 10% 10%

18.000 OHM 18.000 OHM 18.000 OHM 18.000 OHM

Page 23: Danfos - Fcd 300 Config

1.30 1.30 1.30 1.30

OFF OFF OFF OFF

GENERAL GENERAL GENERAL GENERAL

References and limits132 Hz CLOCK WISE 132 Hz CLOCK WISE 132 Hz CLOCK WISE 132 Hz CLOCK WISE

0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz

132.0 Hz 132.0 Hz 132.0 Hz 132.0 Hz

MIN - MAX MIN - MAX MIN - MAX MIN - MAX

0.000 Hz 0.000 Hz 0.000 Hz 0.000 Hz

60.000 Hz 60.000 Hz 85.000 Hz 60.000 Hz

LINEAR LINEAR LINEAR LINEAR

0.50 sec 1.00 sec 1.00 sec 1.00 sec

0.50 sec 1.00 sec 1.00 sec 1.00 sec

0.02 sec 0.02 sec 0.02 sec 0.02 sec

0.02 sec 0.02 sec 0.02 sec 0.02 sec

3.00 sec 3.00 sec 3.00 sec 3.00 sec

3.00 sec 3.00 sec 3.00 sec 3.00 sec

10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz

SUM SUM SUM SUM

0.00% 0.00% 0.00% 0.00%

0.00% 0.00% 0.00% 0.00%

0.00% 0.00% 0.00% 0.00%

0.00% 0.00% 0.00% 0.00%

0.00% 0.00% 0.00% 0.00%

160.0% 160.0% 160.0% 160.0%

0.0 A 0.0 A 0.0 A 0.0 A

2.8 A 2.8 A 2.8 A 2.8 A

0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz

132.0 Hz 132.0 Hz 132.0 Hz 132.0 Hz

-4000.000% -4000.000 -4000.000 -4000.000

4000.000% 4000.000 4000.000 4000.000

OFF OFF OFF OFF

OFF OFF OFF OFF

OFF OFF OFF OFF

Inputs and outputsNO OPERATION NO OPERATION NO OPERATION NO OPERATION

NO OPERATION NO OPERATION NO OPERATION NO OPERATION

NO OPERATION NO OPERATION NO OPERATION NO OPERATION

NO OPERATION NO OPERATION NO OPERATION NO OPERATION

NO OPERATION NO OPERATION NO OPERATION NO OPERATION

REFERENCE REFERENCE REFERENCE REFERENCE

0.0 Volt 0.0 Volt 0.0 Volt 0.0 Volt

10.0 Volt 10.0 Volt 10.0 Volt 10.0 Volt

NO OPERATION NO OPERATION NO OPERATION NO OPERATION

0.0 mA 0.0 mA 0.0 mA 0.0 mA

20.0 mA 20.0 mA 20.0 mA 20.0 mA

10 sec 10 sec 10 sec 10 sec

OFF OFF OFF OFF

0 - IMAX = 0 - 20 mA 0 - IMAX = 0 - 20 mA 0 - IMAX = 0 - 20 mA 0 - IMAX = 0 - 20 mA

NO OPERATION NO OPERATION NO OPERATION NO OPERATION

5000 Hz 5000 Hz 5000 Hz 5000 Hz

5000 Hz 5000 Hz 5000 Hz 5000 Hz

NO OPERATION NO OPERATION NO OPERATION NO OPERATION

5000 Hz 5000 Hz 5000 Hz 5000 Hz

NORMAL NORMAL NORMAL NORMAL

100000 100000 100000 100000

OFF OFF OFF OFF

Special functionsOFF OFF OFF OFF

MANUAL RESET MANUAL RESET MANUAL RESET MANUAL RESET

5 sec 5 sec 5 sec 5 sec

Page 24: Danfos - Fcd 300 Config

OFF OFF OFF OFF

4500 Hz 4500 Hz 4500 Hz 4500 Hz

ON ON ON ON

0.000 0.000 0.000 0.000

1500.000 1500.000 1500.000 1500.000

NO UNIT NO UNIT NO UNIT NO UNIT

DISABLE DISABLE DISABLE DISABLE

0 0 0 0

Serial communication1 1 1 1

9600 BAUD 9600 BAUD 9600 BAUD 9600 BAUD

LOGIC OR LOGIC OR LOGIC OR LOGIC OR

LOGIC OR LOGIC OR LOGIC OR LOGIC OR

LOGIC OR LOGIC OR LOGIC OR LOGIC OR

LOGIC OR LOGIC OR LOGIC OR LOGIC OR

LOGIC OR LOGIC OR LOGIC OR LOGIC OR

LOGIC OR LOGIC OR LOGIC OR LOGIC OR

DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT

10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz

10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz

FC PROFILE FC PROFILE FC PROFILE FC PROFILE

1 sec 1 sec 1 sec 1 sec

OFF OFF OFF OFF

0 0 0 0

Technical functions492.9 h 492.5 h 486.3 h 489.1 h

222.9 h 226.5 h 227.5 h 229.7 h

12.0 kWh 30.6 h 74.1 kWh 31.2 kWh

56 59 55 65

0 0 0 0

0 0 0 0

[1] 0 [1] 13 [1] 13 [1] 13

[1] 0 [1] 988 [1] 1182 [1] 988

[1] 0 [1] 0 [1] 0 [1] 0

DO NOT RESET DO NOT RESET DO NOT RESET DO NOT RESET

DO NOT RESET DO NOT RESET DO NOT RESET DO NOT RESET

NORMAL OPERATION NORMAL OPERATION NORMAL OPERATION NORMAL OPERATION

FCD 311 380 V - 480 V FCD 311 380 V - 480 V FCD 311 380 V - 480 V FCD 311 380 V - 480 V

V 1.44 / 2.00 V 1.44 / 2.00 V 1.44 / 2.00 V 1.44 / 2.00

ID 2.00 2 Kb ID 2.00 2 Kb ID 2.00 2 Kb ID 2.00 2 Kb

ID 1.07 ID 1.07 ID 1.07 ID 1.07

ID 1.50 ID 1.50 ID 1.50 ID 1.50

NONE NONE NONE NONE

DEVICENET DEVICENET DEVICENET DEVICENET

ID 2.06 ID 2.06 ID 2.06 ID 2.06

ID 007.099.171 ID 007.099.173 ID 007.038.252 ID 007.099.164

NOT USED NOT USED NOT USED NOT USED

1.44 1.44 1.44 1.44

2.06 2.06 2.06 2.06

1.50 1.50 1.50 1.50

NO NO NO NO

0.00 0.00 0.00 0.00

0.00 0.00 0.00 0.00

CANBUS CANBUS CANBUS CANBUS

DEVICENET DEVICENET DEVICENET DEVICENET

125 KBAUD 125 KBAUD 125 KBAUD 125 KBAUD

10 s 10 s 10 s 10 s

STOP STOP STOP STOP

BIT 10 = 1 > CTW ACT BIT 10 = 1 > CTW ACT BIT 10 = 1 > CTW ACT BIT 10 = 1 > CTW ACT

Page 25: Danfos - Fcd 300 Config

HOLD CAN HOLD CAN HOLD CAN HOLD CAN

ENABLE ENABLE ENABLE ENABLE

FFFF hex FFFF hex FFFF hex FFFF hex

FFFF hex FFFF hex FFFF hex FFFF hex

FFFF hex FFFF hex FFFF hex FFFF hex

FFFF hex FFFF hex FFFF hex FFFF hex

ERRATA 2 ERRATA 2 ERRATA 2 ERRATA 2

000000000 000000000 000000000 000000000

000000000 000000000 000000000 000000000

000000000 000000000 000000000 000000000

INSTANCE 101 / 151 INSTANCE 101 / 151 INSTANCE 101 / 151 INSTANCE 101 / 151

[1] 000 [1] 000 [1] 000 [1] 000

[1] 528 [1] 528 [1] 528 [1] 528

002 003 004 005

ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP

NO ACTION NO ACTION NO ACTION NO ACTION

[1] 001 [1] 001 [1] 001 [1] 001

[1] 415 [1] 415 [1] 415 [1] 415

[1] 904 [1] 904 [1] 904 [1] 904

[1] 003 [1] 003 [1] 003 [1] 003

[1] 000 [1] 000 [1] 000 [1] 000

[1] 000 [1] 000 [1] 000 [1] 000

Page 26: Danfos - Fcd 300 Config

DANFOSS - FCD 300 Configuration for Conveyor M1, M2, M3, M4, M5, M6, M8, M9, M10 / Beer Filler

M6 M8 M9 M10Operation and Display

ENGLISH ENGLISH ENGLISH ENGLISH

REMOTE REMOTE REMOTE REMOTE

20.000 Hz 20.000 Hz 20.000 Hz 20.000 Hz

SETUP 1 SETUP 1 SETUP 1 SETUP 1

ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP

NO COPY NO COPY NO COPY NO COPY

NO COPY NO COPY NO COPY NO COPY1.00 1.00 1.00 1.00

FREQUENCY [Hz] FREQUENCY [Hz] FREQUENCY [Hz] FREQUENCY [Hz]

REFERENCE [%] REFERENCE [%] REFERENCE [%] REFERENCE [%]

MOTOR CURRENT [A] MOTOR CURRENT [A] MOTOR CURRENT [A] MOTOR CURRENT [A]

POWER [kW] POWER [kW] POWER [kW] POWER [kW]

LOC+DIG CTRL/AS P100 LOC+DIG CTRL/AS P100 LOC+DIG CTRL/AS P100 LOC+DIG CTRL/AS P100ENABLE ENABLE ENABLE ENABLE

DISABLE DISABLE DISABLE DISABLE

DISABLE DISABLE DISABLE DISABLE

ENABLE ENABLE ENABLE ENABLE

NOT LOCKED NOT LOCKED NOT LOCKED NOT LOCKED

LOCAL = STOP LOCAL = STOP LOCAL = STOP LOCAL = STOP

DISABLE DISABLE DISABLE DISABLE

DISABLE DISABLE DISABLE DISABLE

[1] 000 [1] 000 [1] 000 [1] 000

OVERLOAD OVERLOAD OVERLOAD OVERLOAD

Load and motorSPEED OPEN LOOP SPEED OPEN LOOP SPEED OPEN LOOP SPEED OPEN LOOP

CONSTANT TORQUE CONSTANT TORQUE CONSTANT TORQUE CONSTANT TORQUE

1.10 kW 1.10 kW 1.10 kW 1.10 kW

400 V 400 V 400 V 400 V

50 Hz 50 Hz 50 Hz 50 Hz

2.80 A 2.80 A 2.80 A 2.80 A

1420 RPM 1420 RPM 1420 RPM 1420 RPM

AMT OFF AMT OFF AMT OFF AMT OFF

6.000 OHM 6.000 OHM 6.000 OHM 6.000 OHM

180.00 OHM 180.00 OHM 180.00 OHM 180.00 OHM

0% 0% 0% 0%

OFF (0.0 sec) OFF (0.0 sec) OFF (0.0 sec) OFF (0.0 sec)

0.0 sec 0.0 sec 0.0 sec 0.0 sec

COAST/DELAY TIME COAST/DELAY TIME COAST/DELAY TIME COAST/DELAY TIME

COAST COAST COAST COAST

0.1 Hz 0.1 Hz 0.1 Hz 0.1 Hz

10 sec 10 sec 10 sec 10 sec

0.0 Hz (OFF) 0.0 Hz (OFF) 0.0 Hz (OFF) 0.0 Hz (OFF)

ETR TRIP 1 ETR TRIP 1 ETR TRIP 1 ETR TRIP 1

0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz

0.0 Volt 0.0 Volt 0.0 Volt 0.0 Volt

0 % (OFF) 0 % (OFF) 0 % (OFF) 0 % (OFF)

12.67 V 12.67 V 12.67 V 12.67 V

100% 100% 100% 100%

7.56 7.56 7.56 7.56

100% 100% 100% 100%

0% 0% 0% 0%

3.0 Hz 3.0 Hz 3.0 Hz 3.0 Hz

3.0 Hz 3.0 Hz 3.0 Hz 3.0 Hz

10% 10% 10% 10%

18.000 OHM 18.000 OHM 18.000 OHM 18.000 OHM

Page 27: Danfos - Fcd 300 Config

1.30 1.30 1.30 1.30

OFF OFF OFF OFF

GENERAL GENERAL GENERAL GENERAL

References and limits132 Hz CLOCK WISE 132 Hz CLOCK WISE 132 Hz CLOCK WISE 132 Hz CLOCK WISE

0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz

132.0 Hz 132.0 Hz 132.0 Hz 132.0 Hz

MIN - MAX MIN - MAX MIN - MAX MIN - MAX

0.000 Hz 0.000 Hz 0.000 Hz 0.000 Hz

50.000 Hz 60.000 Hz 60.000 Hz 60.000 Hz

LINEAR LINEAR LINEAR LINEAR

1.00 sec 3.00 sec 3.00 sec 3.00 sec

0.50 sec 3.00 sec 3.00 sec 3.00 sec

0.02 sec 3.00 sec 3.00 sec 3.00 sec

0.02 sec 3.00 sec 3.00 sec 3.00 sec

3.00 sec 3.00 sec 3.00 sec 3.00 sec

3.00 sec 3.00 sec 3.00 sec 3.00 sec

10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz

SUM SUM SUM SUM

0.00% 0.00% 0.00% 0.00%

0.00% 0.00% 0.00% 0.00%

0.00% 0.00% 0.00% 0.00%

0.00% 0.00% 0.00% 0.00%

0.00% 0.00% 0.00% 0.00%

160.0% 160% 160% 160%

0.0 A 0.0 A 0.0 A 0.0 A

2.8 A 2.8 A 2.8 A 2.8 A

0.0 Hz 0.0 Hz 0.0 Hz 0.0 Hz

132.0 Hz 132.0 Hz 132.0 Hz 132.0 Hz

-4000.000 -4000.000 -4000.000 -4000.000

4000.000 4000.000 4000.000 4000.000

OFF 0 Hz (OFF) 0 Hz (OFF) 0 Hz (OFF)

OFF 0.0 Hz 0.0 Hz 0.0 Hz

OFF 0.0 Hz 0.0 Hz 0.0 Hz

Inputs and outputsNO OPERATION NO OPERATION NO OPERATION NO OPERATION

NO OPERATION NO OPERATION NO OPERATION NO OPERATION

NO OPERATION NO OPERATION NO OPERATION NO OPERATION

NO OPERATION NO OPERATION NO OPERATION NO OPERATION

NO OPERATION NO OPERATION NO OPERATION NO OPERATION

REFERENCE REFERENCE REFERENCE REFERENCE

0.0 Volt 0.0 Volt 0.0 Volt 0.0 Volt

10.0 Volt 10.0 Volt 10.0 Volt 10.0 Volt

NO OPERATION NO OPERATION NO OPERATION NO OPERATION

0.0 mA 0.0 mA 0.0 mA 0.0 mA

20.0 mA 20.0 mA 20.0 mA 20.0 mA

10 sec 10 sec 10 sec 10 sec

OFF OFF OFF OFF

0 - IMAX = 0 - 20 mA 0 - IMAX = 0 - 20 mA 0 - IMAX = 0 - 20 mA 0 - IMAX = 0 - 20 mA

NO OPERATION NO OPERATION NO OPERATION NO OPERATION

5000 Hz 5000 Hz 5000 Hz 5000 Hz

5000 Hz 5000 Hz 5000 Hz 5000 Hz

UNIT READY NO OPERATION NO OPERATION NO OPERATION

5000 Hz 5000 Hz 5000 Hz 5000 Hz

NORMAL NORMAL NORMAL NORMAL

100000 100000 100000 100000

OFF OFF OFF OFF

Special functionsOFF OFF OFF OFF

MANUAL RESET MANUAL RESET MANUAL RESET MANUAL RESET

5 sec 5 sec 5 sec 5 sec

Page 28: Danfos - Fcd 300 Config

OFF OFF (61 sec.) OFF (61 sec.) OFF (61 sec.)

4500 Hz 4500 Hz 4500 Hz 4500 Hz

ON ON ON ON

0.000 0.000 0.000 0.000

1500.000 1500.000 1500.000 1500.000

NO UNIT NO UNIT NO UNIT NO UNIT

DISABLE DISABLE DISABLE DISABLE

0 0 0 0

Serial communication1 1 1 1

9600 BAUD 9600 BAUD 9600 BAUD 9600 BAUD

LOGIC OR LOGIC OR LOGIC OR LOGIC OR

LOGIC OR LOGIC OR LOGIC OR LOGIC OR

LOGIC OR LOGIC OR LOGIC OR LOGIC OR

LOGIC OR LOGIC OR LOGIC OR LOGIC OR

LOGIC OR LOGIC OR LOGIC OR LOGIC OR

LOGIC OR LOGIC OR LOGIC OR LOGIC OR

DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT

10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz

10.0 Hz 10.0 Hz 10.0 Hz 10.0 Hz

FC PROFILE FC PROFILE FC PROFILE FC PROFILE

1 sec 1 sec 1 sec 1 sec

OFF OFF OFF OFF

0 0 0 0

Technical functions444.6 h 489.5 h 489.6 h 488.5 h

229.8 h 223.4 h 218.7 h 215.4 h

31.2 kWh 46.2 kWh 54.2 kWh 50.2 kWh

64 63 67 69

0 0 0 0

0 0 0 0

[1] 0 [1] 0 [1] 0 [1] 0

[1] 0 [1] 0 [1] 0 [1] 0

[1] 0 [1] 0 [1] 0 [1] 0

DO NOT RESET DO NOT RESET DO NOT RESET DO NOT RESET

DO NOT RESET DO NOT RESET DO NOT RESET DO NOT RESET

NORMAL OPERATION NORMAL OPERATION NORMAL OPERATION NORMAL OPERATION

FCD 311 380 V - 480 V FCD 315 380 V - 480 V FCD 311 380 V - 480 V FCD 311 380 V - 480 V

V 1.44 / 2.00 V 1.44 / 2.00 V 1.44 / 2.00 V 1.44 / 2.00

ID 2.00 2 Kb ID 2.00 2 Kb ID 2.00 2 Kb ID 2.00 2 Kb

ID 1.07 ID 1.07 ID 1.07 ID 1.07

ID 1.50 ID 1.50 ID 1.50 ID 1.50

NONE NONE NONE NONE

DEVICENET DEVICENET DEVICENET DEVICENET

ID 2.06 ID 2.06 ID 2.06 ID 2.06

ID 007.099.176 ID 007.099.203 ID 007.099.168 ID 007.099.167

NOT USED NOT USED NOT USED NOT USED

1.44 1.44 1.44 1.44

2.06 2.06 2.06 2.06

1.50 1.50 1.50 1.50

NO NO NO NO

0.00 0.00 0.00 0.00

0.00 0.00 0.00 0.00

CANBUS CANBUS CANBUS CANBUS

DEVICENET DEVICENET DEVICENET DEVICENET

125 KBAUD 125 KBAUD 125 KBAUD 125 KBAUD

10 s 10 s 10 s 10 s

STOP STOP STOP STOP

BIT 10 = 1 > CTW ACT BIT 10 = 1 > CTW ACT BIT 10 = 1 > CTW ACT BIT 10 = 1 > CTW ACT

Page 29: Danfos - Fcd 300 Config

HOLD CAN HOLD CAN HOLD CAN HOLD CAN

ENABLE ENABLE ENABLE ENABLE

FFFF hex FFFF hex FFFF hex FFFF hex

FFFF hex FFFF hex FFFF hex FFFF hex

FFFF hex FFFF hex FFFF hex FFFF hex

FFFF hex FFFF hex FFFF hex FFFF hex

ERRATA 2 ERRATA 2 ERRATA 2 ERRATA 2

000000000 000000000 000000000 000000000

000000000 000000000 000000000 000000000

000000000 000000000 000000000 000000000

INSTANCE 101 / 151 INSTANCE 101 / 151 INSTANCE 101 / 151 INSTANCE 101 / 151

[1] 000 [1] 000 [1] 000 [1] 000

[1] 528 [1] 528 [1] 528 [1] 528

006 008 009 010

ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP ACTIVE SETUP

NO ACTION NO ACTION NO ACTION NO ACTION

[1] 001 [1] 001 [1] 001 [1] 001

[1] 415 [1] 415 [1] 415 [1] 415

[1] 904 [1] 904 [1] 904 [1] 904

[1] 003 [1] 003 [1] 003 [1] 003

[1] 000 [1] 000 [1] 000 [1] 000

[1] 000 [1] 000 [1] 000 [1] 000

Page 30: Danfos - Fcd 300 Config

Note (Setting range)Operation and Display

Remote control

Value : 0.01 - 100.00

Remote-operated control as parameter 100

Active

Not active

Not active

Active

Forced stop, use saved ref.

Not active

Value : [index 1 - 20] Value : 0 - 999

Overload

Load and motorSpeed control, open loop

Constant torque

Value : 0.18 - 4 kW

Value : 50 - 999 V

Value : 24 - 1000 Hz

Optimisation off

Value : 0.000 - x.xxx Ohm

Value : 0.00 - x.xx Ohm

Value : 0 - 100 %

Value : 0.0 - 0.5 sec.

Value : 0.0 - 10.0 sec.

Coasting during start delay time

Coasting

Value : 0.1 - 10 Hz

Value : 0 - 60 sec.

Value : 0.0 (OFF) - parameter 202

ETR trip 1

Value : 0.0 - 10.0 Hz

Value : 0.0 - 200.0 V

Value : 0 - 100 % of max. DC brake voltage

Value : 0.0 - 100.00 V

Value : 0.0 - 300.0 %

Value : 0.00 - 20.00 V/Hz

Value : -500 - +500% of rated slip compensation

Value : 0 - 100% of max. DC hold voltage

Value : 0.5 - 132.0/1000.0 Hz

Value : 0.5 - 132.0/1000.0 Hz

Value : 0 % of Inom - 100 % of Inom

Value : 0.000 - xxx,xxx Ohm

Value : 0.01 - IMAX

Value : 100 - fM,N x 60 (max. 60000 rpm)

Page 31: Danfos - Fcd 300 Config

Value : 1.00 - 1.50

Off

References and limitsOnly clockwise, 0-132 Hz

Value : Min. reference - Max. reference

Linear

Value : 0.02 - 3600.00 sec.

Value : 0.02 - 3600.00 sec.

Value : 0.02 - 3600.00 sec.

Value : 0.02 - 3600.00 sec.

Value : 0.02 - 3600.00 sec.

Value : 0.02 - 3600.00 sec.

Value : 0.0 - par. 202

Value : -100.00 % - +100.00 %

Value : -100.00 % - +100.00 %

Value : -100.00 % - +100.00 %

Value : -100.00 % - +100.00 %

Value : 0.00 - 100 % of the given reference

Value : 0 - xxx.x % of par. 105

Value : 0.0 - par. 224

Value : 0.0 - par. 226

Value : par. 225 - 132 Hz

Value : -100,000.000 - par. 228

Value : par. 227 - 100,000.000

Value : 0 (OFF) - 100 Hz

Value : 0 - 1000 Hz

Value : 0 - 1000 Hz

Inputs and outputsNo function

No function

No function

No function

No function

Reference

Value : 0.0 - 10.0 Volt

Value : 0.0 - 10.0 Volt

No function

Value : 0.0 - 20.0 mA

Value : 0.0 - 20.0 mA

Value : 0 - 99 sec.

No operation

No function

Value : 150 - 67600 Hz

Value : 150 - 67600 Hz

Drive ready

Value : 150 - 10000 Hz

Normal ramp stop

Value : 1 - 999999

Value : 0 ms - 100 ms

Special functionsOff

Manual reset

Value : 0 - 10 sec.

Value : 0.0 - fMAX

Value : fMIN - 132/1000 Hz (parameter 200)

Value : -100,000.000 - par. 205 RefMAX

Value : par. 204 ReMIN - 100,000.000

Value : par. 223 - IMAX

Output current 0 - IMAX 0 - 20 mA

Page 32: Danfos - Fcd 300 Config

Value : 0 - 60 sec. (61 = OFF)

Value : 3000 - 14000 Hz

Off

Value : 0 - 50 V

Serial communicationValue : 1 - 126

9600 Baud

Logic or

Logic or

Logic or

Logic or

Digital input

Logic or

Logic or

Value : 0.0 - nparameter 202

Value : 0.0 - nparameter 202

Value : 1 - 99 sec.

Off

Technical functionsRange : 0 - 130,000.0

Range : 0 - 130,000.0

Range : 0 - 9999

Range : 0 - 9999

Range : 0 - 9999

Range : 0 - 9999

Value : [Index 1 - 10] Error code 0 - 44

Value : [Index 1 - 10]

Value : [Index 1 - 10]

No reset

No reset

Normal Operation

Devicenet

125 kbps

Value : 1 - 99 sec.

Stop with auto restart

This parameter is read only

Value : -100,000.000 - Par. 415 FBMAX

Value : Par. 414 FBMIN - 100,000.000

Page 33: Danfos - Fcd 300 Config

Ho;d the device in bus-off state

Value : 0000 - FFFF Hex

Value : 0000 - FFFF Hex

Value : 0000 - FFFF Hex

Value : 0000 - FFFF Hex

Errata 2

Value : 0 - 63

Active set up

Not active

Read only

Read only

Read only

Read only

Read only

Read only

Value : Sub index 1 (PCD 1) [Par. Number] Sub index 2 (PCD 2) [Par. Number]

Value : Sub index 1 (PCD 1) [Par. Number] Sub index 2 (PCD 2) [Par. Number]