daikin pcr0720 - super multi nx [small]
TRANSCRIPT
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
1/14
Multi-Split Type Air Conditioners D series
With DC Inverter and Swing Compressor
Cooling Only & Heat Pump [50/60 Hz]
The Comfort and Luxury You Deserve
PCR0720
All rights reservedPrinted in Japan 12/06/003 DN
c
DealerHead Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global/
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning Daikin Industries, Ltd.s products are manufactured for export to numerous countries throughout the
world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a
particular country. Prior to purchase, please therefore confirm with your local authorised importer,
distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for
use, in the region where the product will be used. This statement does not purport to exclude, restrict
or modify the application of any local legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Printed on 100% recycled paper with soy ink.Specifications, designs and other content appearing in this brochure are current as of December 2006 but subject to change without notice.
ISO 14001 is the standarddefined by theInternational Organization for Standardization
(ISO) relating to environmental managementsystems. Our group has been acknowledgedby an internationally accredited complianceorganisation as having an appropriateprogramme of environmental protectionprocedures and activities to meet therequirements of ISO 14001.
AboutIS O14001
ISO 9001 is a plant certification systemdefined by theInternational Organization for
Standardization (ISO) relating to qualityassurance. ISO 9001 certification coversqualityassuranceaspects related to the design, development, manufacture,installation, and supplementary service ofproducts manufactured at the plant.
AboutI SO9001
JMI-0107 JQA-1452
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
2/14
Contents
Air condition your entire home
with a single outdoor unit.
Air condition your entire home
with a single outdoor unit.
Concepts
Main features
Product lineup
Functions
Specifications
Options
Capacity tables
3
5
9
15
21
22
23
The Da ikin Super Multi NX lets you build a highly efficient multi room air
conditioning system by connecting up to four indoor units to a single outdoor unit.
The series incl udes a wide variety of indoor units, so it is easy to select a model that
blends in unobtrusively and allows you to create a dcor that matches your personality.
A single compact outdoor unit allows you to make more efficient use of available
space in the installation location, such as a balcony. The individual indoor units in
different roomsthe living room, study, and bedrooms, for examplecan be c ontrolled
independently to match your family s lifestyle. Super Multi NX makes your home
If you would like your conditioners
to match your personal dcor
Super Multi NX is the knowledgeable choice.
If you wish to make more effective use
of the space on your balcony
If you want your family to be
comfortable
1 2
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
3/14
Concepts Concepts
Key concepts for Super Multi NX
Enjoy the comfort and luxury of your dreams. I n1969, Daikindevelopedthefirst multi roomair conditioningsysteminJapanthatneededjust oneoutdoor unit. Over theensuing35years, Daikinhas built anenviable
reputationwith theconstant progress of its technology. S uper Multi N X requires only a
singleoutdoor unit tomaintainpleasant comfort inuptofour rooms. Whereoutdoor unit
installationspaceis limited, it is theideal choice. A ir conditioner settings for each room
canbecontrolledindividually tosuit thepreferenceof each person. Whileoptimisingpersonal comfort, Super Multi N X uses DC inverter technology toreduceenergy waste.
2MKD series 3MK(X)D series
Up to 3 indoor units can be connected.Up to 2 indoor units can be connected.
4MK(X)D series
Up to 4 indoor units can be connected.
The DC motor, swing compressor and other
advanced technologies make for energy-
effici ent operation that achiev es high CO Ps.
The quiet operation mode helps create a more
pleasant living environment. DC inverter
power control provides comfortable
The wide range of indoor unit options
provides ample choice. A single compact
outdoor unit reduces installation space
requirements, while long maximum piping
lengths provide flexibility for connections.
The indivi dual indoor units in different rooms
can be controlled independently. The priority-
room setting function lets you specify a room
to receive preference in air conditioning
Connect 4 indoor units to a single outdoor unit
Ne wDesign
Ne wDesign
Ne wDesign
3 4
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
4/14
5 6
1
2
3
Reluctance DC motor
Swing compressor
PAM control
1
2
3
What is COP?An air conditioner's COP (coefficient of performance) indicates howefficiently it uses energy. A high COP means high energy efficiency.
COP =Capacity (kW)
Power consumption (kW)
* During rated capacity operation of 4 indoor units
(2.5 + 2.5 + 2.5 + 6.0 kW class).
The reluctance DC motor is much more
efficient than conventional AC and DCmotors. Its advanced design has
improved low-capacity
operation by morethan 20%.
The swing compressor decreases friction
and vibration and also prevents theleakage of refrigerant gas
during compression.
This gives much quieterand more efficient
operation.
Pulse Amplitude Modulation (PAM) controlreduces energy loss by controlling the amount
of switching on/off of the converter.
Neodymium magnetThe reluctance DC motor employsneodymium magnets. These magnetsare approximately 10 times strongerthan ferrite magnets.
Neodymiummagnet Ferrite magnet
Energy efficiency is increased by reducingoperational friction and refrigerant gas leakage.
Swing bush
Integral piston of blade and roller
Refrigerant gas
500 30 60 90 120
60
70
80
90
Small load Large loadL ow c ap ac it y H ig h ca pa ci ty
Reluctance DC Motor
ConventionalDC motor
More than 20%
AC motor
Rotational speed (rps)
Motorefficiency(%)
Loss Loss
Powersupply
POWER
Powerfactor
Converterefficiency
Inverterefficiency
Main features Main features
High energy efficiency through advanced
technologies delivers high COP.
Convenient features to realise your
ideal environment
COP during cooling operation (4MXD80BVMA)
COP during heating operation (4MXD80BVMA) 4.00
3.32
ntelligent
technologies
deal
environment
High energy efficiency for high COP
Daikin energy-saving technologies
Indoor unit
Outdoor unit
Duringcooling operation
Settemp.
Temp.
Time
Starts
Too cool
Not cool
DC inverter power control uses its
full capacity at startup to cool/warm
quickly. As soon as the settemperature is reached, it carefully
adjusts current frequency to
prevent temperature fluctuation andenergy loss.
Non-inverter type
DC inverter type
DC inverter power control gives you greater comfort
25 dB
-20
-10
0
10
20
30
40
50
46CDB
15.5CWB
Outdoortemp.
Heatpumptype
Even during a cold season, a crowded party or a sudden change in the
indoor temperature can leave a room overheated. With SUPER MULTI NX,cooling operation is possible even during lower outdoor temperatures.
Note: This information is available for heat pump type.
Cooling
Heating
A quiet outdoor unit is essential for your comfort and peace in your neighbourhood. SUPER MULTI NXachieves a quiet sound level of 43 dB during Outdoor Unit Quiet Operation or Night Quiet Mode of the2/3MKD58D. The minimum outdoor unit sound level is 39 dB.*
* Achievable when:1. A single 2.5 kW class indoor unit is operating.2. Indoor Unit Quiet Operation is selected for all indoor units in operation.3. Outdoor Unit Quiet Operation is selected.Note: Capacity may decrease when quiet functions are selected.
A quiet indoor unit is important for your personal comfort. SUPERMULTI NX offers the quiet sound level of 25 dB during Indoor UnitQuiet Operation of the FTKD25D.Note: Capacity may decrease when quiet functions are selected.
Quiet operation
Comfortable temperature control
Wide operation range
Rustling of leaves Library
T ic ki ng of a w al l c lo ck T yp ic al of fi ce
25 dB is so quiet you can even hear whispers
50403020 (dB)
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
5/14
7 8
Only 240 mm is required above the ceiling forinstallation.
The ample maximum piping length of 70 m permits
more freedom in the placement of air conditioner unitsand facilitates the optimisation of interior space.
Max.pipinglength
Total
Between rooms 25 m
2MKD58
35 m
3MKD58
3MXD68
45 m
3MKD75
60 m
4MKD100
4MXD80
70 m
4MKD75
The stylish flat panel design of the wall-mounted type provides an excellent matchfor the most refined of interiors.
Model name
Stylish indoor units for elegant interiors
Compact outdoor units for a less obtrusive exterior look
Long piping lengths for installation flexibility
Needs just one outdoor unitkeep your home exterior beautiful!
The system requires only a singleoutdoor unit. The compact design
provides installation flexibility andtakes up less space, for a less
obtrusive exterior look.
When Inverter Powerful Operation is selected in the priority room, the indoor unit capacity in the priority room is
increased by shifting capacity from units in other rooms. After 20 minutes, all units automatically return to their
original settings.
Note: Capacity in other rooms may decrease slightly.
Priority-Room Setting also allows Outdoor Unit Quiet Operation to be selected by one command* from the
priority room.
* If Priority-Room Setting has not been s et, the Outdoor Unit Quiet Operation button must be pushed on thewireless remote controller of all indoor units oper ating at that time.
Convenient remote controllers
Preferential air conditioning
The operation mode (cooling/heating) of t he indoor unit in the priority room is given preference. When the
operation modes of the units in other rooms are different from the unit in the priority room, the units in the other
rooms wait on standby.
Note: Operation mode can not be changed from other rooms.
Livingroom
RoomC
RoomB
RoomA
Priorityroom
Livingroom
RoomC
RoomB
RoomAPower Up!
Priorityroom
5-roomcentralised controller(option)
Central remote controller(option)
Unifiedon/off controller(option)
Wireless remote controller
Initial settingrequired duringinstallation
Priority-Room Setting delivers priority capacity to a prioritised room when using multi-split air conditioners.
After a priority room is selected, it receives preferential air-conditioning plus priority control over the 3 functions below.
A variety of convenient controller systems permit individual control ofsettings such as temperature, airflow volume, and operation duration.
Priority setting with Inverter Powerful Operation1
Priority setting with operation mode2
Priority setting with Outdoor Unit Quiet Operation3
Wide array of choices to matchyour interior
Individual control for each room to matchyour familys lifestyle
Main features Main features
nterior &
exteriorflexibility
ndividual
control
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
6/14
9 10
Outdoor units
Indoor units
Connectable toup to2 indoor units
Wall -mountedtype
Connectable toup to4 indoor units
7.1 kW6.0 kW5.0 kW3.5 kW2.5 kW
Cooling only
Heat pump
FTKD35DVM
FTXE35BVMA
FTKD25DVM
FTXE25BVMA
Cooling only
Heat pump
FTKD71FVM
FTXD71FVM
FTKD60FVM
FTXD60FVM
FTKD50FVM
FTXD50FVM
Model nameModel Capacity c lass M ax. piping length M ax. height difference
Cooling only
Heat pump
CDKD35EAVM
CDXD35EAVMA
CDKD25EAVM
CDXD25EAVMA
Cooling only
Heat pump
CDKD60CVM
CDXD60CVMA
CDKD50CVM
CDXD50CVMA
CDKD35CVM
CDXD35CVMA
CDKD25CVM
CDXD25CVMA
Cooling only
Heat pump
FLK60AVMA
FLX60AVMA
FLK50AVMA
FLX50AVMA
FLK35AVMA
FLX35AVMA
FLK25AVMA
FLX25AVMA
Cooling only 4MKD100DVM 10 kW 70 m 15 m
Heat pump 4MXD80BVMA 8.0 kW 70 m 15 m
Cooling only 4MKD75DVM 7.5 kW 60 m 15 m
Cooling only3MKD75DVM 7.5 kW 60 m 15 m
Heat pump 3MXD68BVMA 6.8 kW 45 m 15 m
3MKD58DVM 5.8 kW 45 m 15 m
Cooling only 2MKD58DVM 5.8 kW 35 m 15 m
Duct-connectedtype
Floor/cei ling-s uspendeddual type
700 mm width
900/1,100mm width
Coolingonly type
Possible combinations for indoor and outdoor units
Heatpumptype
ModelCapacity class
Model Capacity class
7.1 kW6.0 kW5.0 kW3.5 kW2.5 kW2.0 kW
3MKD58D
3MKD75D
4MKD75D
3MXD68B
4MXD80B
2MKD58D
4MKD100D
Connectable toup to3 indoor units
Ne wDesign
Wall-mounted type
An attractive match for large rooms with refined interiors is providedby the stylish flat panel design.
Duct-connected type
Fits in shallow ceiling recesses only 240 mm deep thanks to the newslim and compact design.
Floor/ceiling-suspended dual type
Chose either ceiling-suspended or floor-level installation for thisattractive model with a beautiful, rounded design.
Product lineup Product lineup
A wide range of models to choose from that deliver excellent comfort and
convenience
An array of indoor unit models with innovative and attractive designs make
it easy to find the ideal match for each room in your home.
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
7/14
11 12
W all-Mounted Type Indoor Units
Heat pump
2.5 kW class
FTKD25DVM
3.5 kW class
FTKD35DVM
2.5 kW class
FTXE25BVMA
3.5 kW class
FTXE35BVMA
Cooling only
GOODDESIGNAWARD2004
INJAPAN
Flat panel can be cleanedwith just a single pass of a
cloth across its smooth
surface.
FTKD25D
37/28/25 dB
FTKD35D
39/29/26 dB
(H/L/SL)
Wall-mounted type indoor units achieve quiet sound
levels of 25 dB during Indoor Unit Quiet Operation.
Models in the CDK(X)D-EA series are only 700 mm in widthand 21 kg in weight, so are easily installed in limited spaces.
Just 200 mm in height, all models can be installed in roomswith as little as 240 mm depth between the drop ceiling and
ceiling slab, making them ideal for even shallow ceilings.
Quiet operation sound level of only 29 dB is
achieved for 2.5 and 3.5 kW class models.
* Locally obtained parts
1. To prevent an increase in operation noise, avoid installing the air suctiongrille directly below the suction chamber.
2. Grilles, piping connections, ducts, and installation parts should beobtained locally.Duct-connected types do not have drain-up pumps.
3. The signal receiver unit must be located near the air suction inlet,because the unit includes a sensor that detects room temperature.
Suction grille (KDGF19A45)
OptionSignals from the wireless remote controllerare transmitted to the signal receiver.
240 mm
200 mmOnly 700 mm
Morecompact
Dimensions (Hx W x D)
Weight
Airflow rate (H)
External static pressure
200 x 700 x 620mm
21kg
8.7 m3/min
30Pa
200 x 900 x 620 mm
25kg
40Pa
CDK(X)D25EA CDK(X)D35EA CDK(X)D25C CDK(X)D35C
9.5 m3/min 10 m
3/min
Notes:
AIR
AIR
Air suction
grille*Signalreceiver
Air dischargeduct*
Suspension bolt*
Air dischargegrille*
Signal receiver wireLength = 1,900 mm
Chamber
Air filter*
700 mm width type
900/1,100 mm width type
CDK(X)D-EA
2.5 kWclass 3.5 kWclass 5.0 kWclass 6.0 kWclass
Coolingonly
Heatpump
CDKD25EAVM
CDXD25EAVMA
CDKD35EAVM
CDXD35EAVMA
Coolingonly
Heatpump
CDKD25CVM
CDXD25CVMA
CDKD35CVM
CDXD35CVMA
CDKD50CVM
CDXD50CVMA
CDKD60CVM
CDXD60CVMA
Product lineup Product lineup
Duct-Connected Type Indoor Units
Uses a Titanium Apatite Photocatalytic Air-Purifying
Filter. Titanium apatite is a photocatalytic material
with high adsorption power. It effectively adsorbsand removes bacteria and viruses along with mould
and odours. This filter is available for
FTK(X)D50/60/71F.6.0 kW class
FTKD60FVM
FTXD60FVM
5.0 kW class
FTKD50FVM
FTXD50FVM
7.1 kW class
FTKD71FVM
FTXD71FVM
Cooling only
Heat pump
Clean air
Slim and compact design
Quiet operationEasy cleaning
Quiet operation
NewDesign
Titanium ApatitePhotocatalyticAir-purifying Filter
Air filterCatches dust
NewFunction
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
8/1413 14
FLK25A
37/31/28 dB
FLK35A
38/32/29 dB
FLK50A
47/39/36 dB
FLK60A
48/41/38 dB
(H/L/SL)
The FLK25A achieves the quiet sound level of28 dB. Indoor Unit Quiet Operation decreases the
operation sound by 2 or 3 dB from the low setting
fan speed.
The rounded design of these slim and lightweight units
makes them the perfect choice for rooms without falseceilings. Ceiling-suspended installation frees up floor and
wall space, and floor-level installation is possible without
loss of warm air.
Heatpump
2.5 kW class
FLK25AVMA
FLX25AVMA
3.5 kW class
FLK35AVMA
FLX35AVMA
5.0 kW class
FLK50AVMA
FLX50AVMA
6.0 kW class
FLK60AVMA
FLX60AVMA
Coolingonly
Floor/Ceiling-Suspended Dual Type Indoor Units
Product lineup Functions
Two-way installation
Vertical Auto-Swing and Wide-Angle Louvres realise a
comfortable airflow spreading throughout a large room, air-
conditioning the whole room evenly.
Comfortable airflow
Quiet operation
Ceiling-Suspended Installation
Floor-Level Installation
Power-AirflowDual Flaps
ComfortableAirflo
w
Wide-Angle Louvres
3-DAirflow
ComfortControl
Indoor UnitQuietOperation
Outdoor Unit QuietOperation
NightQuiet Mode
Inverter PowerfulOperation
Lifestyle
Convenience
Priority-Room Setting
Home LeaveOperation
Indoor UnitOn/OffSwitch
Cleanliness
24-Hour On/Off Timer
Timers
NightS etMode
Auto-Restart afterPower Failure
Self-Diagnosis withDigital Display
Mould-Proof Air Fi lter
AnticorrosionT reatmentofOutdoor HeatExchanger Fi ns
Intelligent Eye
Automatic Operation
AutoFan Speed
Programme Dry
Function
Horizontal Auto-Swing(leftandright)
Vertical Auto-Swing(upand down)
WorryFree
Wipe-CleanFlat Panel
Air-Purifying Filter
PhotocatalyticDeodorising Filter
TitaniumApatitePhotocatalyticAir-Purifying Filter
Functions
ModelsDuct-connectedtype
Floor/ceiling-suspended
dual type
Outdoor unitsIndoor units
Wall -mountedtype
CDK(X)D25/35EACDK(X)D25/35/50/60CFTXE25/35BFTKD25/35D FTK(X)D50/60/71F FLK(X)25/35/50/60A
(Heat pump type only)
EconoMode
Mould-ProofOperation
Ne w
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
9/1415 16
30Unit: minutes
Time
Cooling
Heating
60
Set temp. before
Off timer beginsto operate
Off timer t urns on Off timer s tops ai r cond it ioner
Heating: the flaps descend to blowwarm air directly down to the floor toquickly warm the whole room.
Cooling: the flaps flatten out duringoperation so that cool air slides offto reach the farthest corners of theroom.
When you are in the room
When you go out
Intelligent Eye with its infrared sensorautomatically controls air conditioner operationaccording to human movement in a room. Whenthere is no movement, it adjusts the temperature
by 2C for energy savings of up to 20% for coolingoperation and 30% for heating operation. Intelligent Eye isavailable for all wall-mounted models.
Inverter Powerful Operation boosts cooling/heatingperformance for a 20-minute period. This isconvenient both when you first turn on your airconditioner and when you want to quickly change
the temperature during operation.
A uniform temperature is
achieved throughout the
entire room.
Vertical Auto-Swing automaticallymoves the flaps up and down andHorizontal Auto-Swingautomatically moves the louvres
to the left and right. 3-D Airflow combines Vertical andHorizontal Auto-Swing to circulate air to every part ofa room for uniform cooling/heating of even large spaces.
Power-Airflow Dual Flaps and Wide-AngleLouvres work in tandem to precisely controlboth vertical and horizontal airflow for evendistribution of air.
The unit can be convenientlystarted manually in the eventthe wireless remote controlleris misplaced or the wireless
remote controller batteries are notcharged.
Cooling operation: Room temperature is raised by 0.5Cafter 60 minutes, while minimum outdoor unit sound levelsare maintained. If the outdoor temperature is below 27C,room temperature is raised by a further 0.5C after 90minutes except for FTKD25/35D.Heating operation: Room temperature is lowered by 2Cafter 60 minutes.
Pressing the Off timer button automatically selectsthe Night Set Mode. This function prevents anysudden change in room temperature by gentlyraising/lowering the temperature before the air
conditioner stops, so you can sleep comfortably.
Power-Airflow Dual Flaps
Home Leave Operation prevents large rises or fallsin the indoor temperature by continuing operation*while you are sleeping or out of your home. Thismeans that an air-conditioned welcome awaits
when you wake or return. It also means that the indoortemperature can quickly return to your favourite comfortsetting.
* Home Leave Operation can be selected for any temperature from 18 to32C for cooling operation and 10 to 30C for heating operation.
Start Home Leave Operation simply bypushing its button on the remote controller.
When you are out of your home, your air conditioner prevents large risesin the indoor temperature by continuing to operate using Home LeaveOperation settings.
When you return, you will be greeted by anair-conditioned room. Just push the HOME
LEAVE button again to return to yourprevious settings.
During cooling operation, 23C for the room temperature s etting,and 28C for the home leave sett ing.
23C
Wide-Angle Louvres
The louvres can beadjusted by hand for theFTKD25/35D, FTXE25/50Band FLK(X)25/35/50/60A.The louvres can beadjusted with the wirelessremote controller for theFTK(X)D50/60/71F.
28C
23C
Entirely coversa spacious room
From a cornerto the centre
Refer to page 14 to check the functions offered by individual models.
Functions Functions
+1C+0.5C
2C
Energy savings plus quick return to favourite comfort setting levels Uniform cooling/heating of the whole living room
Econo Mode
Econo Mode is a function that reduces the maximum
running current and the maximum power consumption of
the outdoor unit to the rated values. This mode is useful for
preventing circuit breakers from being overloaded by the
use of multiple air conditioners and other electrical
devices. The function is easily activated from the remote
controller by pushing the ECONO button. Econo Mode is
available for the FTKD25/35D.
From start up until settemperature is reached
Maximum
Rated
This diagram is a representation for illustrative purposes only.
Maximum capacity decreases during Econo Mode, requiring
more time to reach the set temperature.
Maximum duringnormal operation
Running current andpower consumption
Time
Normaloperation
EconoMode
Maximum duringEcono Mode
One push!!
Push again!!
Indoor Unit On/Off Switch
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
10/1417 18
FTKD/25/35D
FTK(X)D50/60/71F
Titanium apatite is a photocatalytic material with
high adsorption power. Besides mould and odours,
titanium apatite also effectively adsorbs and
decomposes bacteria and viruses across its entiresurface. The photocatalyst is activated simply by
exposure to natural light. This filter is installed in allwall-mounted units.
Bacteria Removal Test
Testing method: dropping method
Result certificate: No. 012553-1 and 012553-2
Testing organisation: Japan Spinners Inspecting Foundation
Titanium Apatite Photocatalytic Air-Purifying Filter
SUPER MULTI NX indoor units offer a range of features,including advanced photocatalytic air-purifying filters, to help
keep indoor air clean. As well as decomposing unpleasant
odours, these advanced filters are able to remove bacteriaand viruses.
Outdoor Unit Quiet Operation
Intelligent Eye
Cancels On/Off Timer
24-Hour On Timer
24-Hour Off Timerand Night Set Mode
Sets timer
Displays time
On/Off Switch
Home Leave Operation
Inverter Powerful Operation
Sets room temperature
Horizontal Auto-Swing(left andri ght)
Vertical Auto-Swing
(upand down)
Selects fan speedandIndoor Unit Quiet Operation
Selects mode: cooling,dry, fan-only operation
Outdoor Unit Quiet Operation
Intelligent Eye
Cancels On/Off Timer
24-Hour On Timer
24-Hour Off Timerand Night Set Mode
Sets timer
Displays time
On/Off Switch
Econo Mode
Inverter Powerful Operation
Sets room temperature
Mould-Proof Operation
Selects mode: automatic, cooling,heating, dry, fan-only operation
Vertical Auto-Swing(upand down)
Selects fan speedandIndoor Unit Quiet Operation
When cooling or dry operation is stopped, fan-onlyoperation runs automatically for one hour. This
airflow dries the inside of the indoor unit to reduce
the generation of mould and the odours caused bymould.
Mould-Proof Operation
Refer to page 14 to check the functions offered by individual models.
FTKD25/35D, FTXE25/35B and FLK(X)25/35/50/60A
The filter removes bacteria and viruses, and
impurities such as dust, pollen and cigarettesmoke from the air. Its r emoval rate for bacteria
and viruses has been measured and verified by
the Japan Food Research Laboratories.
Bacteria Removal Test
Testing method: dropping methodResult certificate: No.298051308-001
Virus Removal Test
Testing method: washout method
Result certificate: No.298051308-002
Testing organisation: Japan Food Research Laboratories
This filter decomposes odours and even removes
bacteria and viruses. This power is maintainedsimply by exposing the filter to sunlight once every
6 months.
Bacteria Removal Test
Testing method: dropping method
Result certificate: No. 298081197-003
Virus Removal Test
Testing method: washout method
Result certificate: No. 298081197-004
Testing organisation: Japan Food Research Laboratories
Air-Purifying Filter
Photocatalytic Deodorising Filter
FTK(X)D50/60/71F
Functions Functions
Clean air with less dust or odours Easy-to-use wireless remote controller
FTKD25/35D, FTXE25/35B andF LK(X) 25/35/50/60A
Air-purifyingfilter
Filter type Photocatalyticdeodorisingfilter
FTK(X)D50/60/71F
Titanium apatitephotocatalyticair-purifying filter
UnnecessaryMaintenance Expose to sunlightfor 6 hours onceevery 6 months
Soak in watercontaining detergentonce every 6 months
3 monthsReplacement Unnecessary3 years
1 pieceNumber 1 piece2 pieces
Titanium ApatitePhotocatalyticAir-purifying Filter
Air filterCatches dust
NewFunction
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
11/1419 20
See page 16
See page 15
See page 16
See page 8
See page 16
Comfortable Airflow
Comfort Control
Lifestyle Convenience
Cleanliness
Timers
Worry Free
Others
The microprocessor automatically controls fan speed toadjust the room temperature to the set temperature.
This function automatically reduces the level of humiditywhile maintaining the preset room temperature.
This function automatically selects cooling or heatingoperation mode based on the room temperature at startup.
This function is convenient for boosting cooling/heatingperformance for a 20-minute period both when you firstturn on your air conditioner and want to quickly changethe room temperature.
See page 15
Econo Mode reduces the maximum running current andthe maximum power consumption of the outdoor unit tothe rated values. This is useful when using multiple air
conditioners and other electrical devices at the sametime.
When this function is set, it is convenient for selecting Inverter
Powerful Operation, Outdoor Unit Quiet Operation andoperation mode. Initial setting is required during installation.
Home Leave Operation continues operation to preventa room from becoming too hot or cold while you aresleeping or out of your home. Select any temperaturefrom 18 to 32C for cooling operation and 10 to 30C forheating operation.
There is a second On/Off switch on the body of the indoorunit to prevent any problems if the wireless remotecontroller is misplaced.
This timer can be preset to start and stop at any timewithin a 24-hour period. The air conditioner is started/stopped simply by pressing the On/Off timer button onthe wireless remote controller.
Pressing the Off timer button automatically selects theNight Set Mode. This function prevents any suddenchange in room temperature by g ently raising/loweringthe temperature before the air conditioner stops, so youcan sleep comfortably.
Refer to page 14 to check the functions offered by individual models.
The air conditioner memorises the settings for mode,airflow, temperature, etc., and automatically returns tothem when power is restored after a power failure.
Malfunction codes for each indoor unit are shown on thedigital display panel of the wireless remote controller forfast and easy maintenance.
The outdoor units heat exchanger fins are processedusing a special anticorrosion treatment. The surface iscovered with a thin acrylic resin layer to enhance the finsresistance to acid rain and salt corrosion.
Charging with additional refrigerant is not required even forlong runs of piping. Available for cooling only type.
The wall-mounted type indoor unit is designed so that drainpiping can be connected to either the left or right side.
The owner can lock the operation mode to prevent it from beingchanged in individual rooms. This is convenient in small hotels.
Microcomputer checking and diagnosis of wiring errors duringinstallation prevents any problems.
After defrosting or when starting heating operation, air ispreheated before discharge to prevent uncomfortable colddrafts.
During low outdoor temperatures, this function preheats thecompressor to shorten the time required to discharge warm air.
Before starting heating operation, a sensor checks for frost inthe outdoor unit and performs automatic defrosting if necessaryso that only warm air is discharged.
See page 16
Power-Airflow Dual Flaps can flatten out during coolingoperation to deliver cool air to the corners ofa room. The flaps can d irect warm air straight down tothe floor during heating operation.
Power-Airflow Dual Flaps
See page 16
Smoothly curved Wide-Angle Louvres provide wideairflow coverage for effective cooling/heating no matterwhere the indoor unit is placed in a room.
Wide-Angle Louvres
See page 16
This function combines Vertical and HorizontalAuto-Swing to circulate a cloud of cool/warm air right
to the corners of even lar ge spaces.
3-D Airflow
Auto Fan Speed
Programme Dry Function
Automatic Operation
Inverter Powerful Operation
Priority-Room Setting
Home Leave Operation
Indoor Unit On/Off S witch
24-Hour On/Off T imer
Night Set Mode
Auto-Restart After Power Failure
Self-Diagnosis with Digital Display
Chargeless
Flexibility
Either Side Drain (left or right)
Anticorrosion Treatmentof Outdoor Heat Exchanger Fins
See page 15
Intelligent Eye with its infrared sensor automaticallycontrols air conditioner operation according to humanmovement in a room. When there is no movement, itadjusts the temperature by 2C for energy savings ofup to 20% for cooling operation and 30% for heatingoperation.
Intelligent Eye
See page 16
Horizontal Auto-Swing automatically moves the louvresto the left and right to cover a room with cool/warm air.
Horizontal Auto-Swing (left and right)
See page 16
Vertical Auto-Swing automatically moves the flaps up anddown to provide an even distribution of air throughout a room.
Vertical Auto-Swing (up and down)
See page 6
Outdoor unit operating sound levels are decreased by 3 dBfrom the rated operation sound using the wireless remotecontroller.
Outdoor Unit Quiet Operation
Outdoor unit operating sound levels are automaticallydecreased by 3 dB from the rated operation sound whenthe outdoor temperature has dropped by 6C from themaximum temperature recorded during the daytime.Initial setting is required during installation.
Night Quiet Mode
Worry FreeCooling/Heating Mode L ock
Wiring Error Check
Hot-Start Function
Quick Warming FunctionComfort Control
Automatic DefrostingThe air filter net is impregnated with a safe, odourlessmould preventative to make the filter virtually immune to
mould.
Mould-Proof Air Filter
See page 11
The flat panel models can be cleaned with only the singlepass of a cloth across their smooth surface. The flat panelcan also be easily removed for more thorough cleaning.
Wipe-Clean Flat Panel
The filter removes bacteria and viruses, and impuritiessuch as dust, pollen and cigarette smoke from the air.
Air-Purifying Filter
This filter decomposes odours and even removesbacteria and viruses. This power is maintained simply byexposing the filter to sunlight once every 6 months.
Photocatalytic Deodorising Filter
Econo Mode
See page 17
Mould-Proof Operation automatically runs fan-onlyoperation for 1 hour when cooling or dry operation isstopped. This airflow prevents the generation of mouldand mould odours inside the indoor unit.
Mould-Proof Operation
See page 6
Indoor Unit Quiet OperationIndoor unit operating sound levels are decreased by 2 or3 dB from the low setting fan speed using the wirelessremote controller.
See page 17
See page 17
See page 17
This filter combines the Air-Purifying Filter and
Titanium Apatite Photocatalytic Deodorising Filter
in a single highly effective unit. The filter traps
microscopic particles, decomposes odours and
even removes bacteria and viruses. It lasts for 3
years without replacement if washed about once
every 6 months.
Titanium Apatite PhotocatalyticAir-Purifying Filter
Functions Functions
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
12/1421 22
Specifications Specifications and Options
SpecificationsOutdoor units
Indoor units
Duct-connected type
1 phase, 220-240 V, 50 Hz/1 phase, 220-230 V, 60 Hz
Hermetically sealed swing type
25 (for each room)
15 (between indoor and outdoor units)
Ivory white
2MKD58DVM
35 (total)
Cooling only Heat pump
Cooling
Heating
Cooling
Heating
dB (A)
mm
kg
CDB
CWB
m
g/mm
4MKD100DVM
Pale ivory
770 x 900 x 320
56
70 (total)
4MKD75DVM
48/45 *1
4MXD80BVMA
Pale ivory
908 x 900 x 320
73
70 (total)
20(for40mormore)*2
46/43 *1
55
3MKD75DVM
10 to 46
Chargeless
3MXD68BVMA
Ivory white
735 x 936 x 300
59
45 (total)
20(for30mormore)*2
735 x 936 x 300
Notes:*1. Rated sound level/sound level when using outdoor unit quiet operation. *2. Additional charging of 20 g/m is required for the 3MXD68BVMA when the piping length is 30 m or more and for the 4MXD80BVMA when the piping length is 40 m or more.
60 (total)
58
FTKD50FVM
16.8 (593)
44/35/32
FTKD35DVM
9.0 (318)
39/29/26
FTKD60FVM
17.5 (618)
45/36/33
FTKD71FVM
18.3 (646)
46/37/34
9.5
FTXE25BVMA
7.8 (275)
37/30/27
37/30/27
9.5
FTXE35BVMA
7.7 (272)
38/32/29
38/31/28
FTXD50FVM
16.8 (593)
17.5 (618)
44/35/32
42/33/30
FTXD60FVM
17.5 (618)
18.7 (660)
45/36/33
44/35/32
FTXD71FVM
18.3 (646)
19.8 (699)
46/37/34
46/37/34
9.5
FTKD25DVM
8.9 (314)
37/28/25
9.5
Cooling only Heat pump
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
m3/min(cfm)
dB (A)
mm
kg
mm
6.4
12.7
6.4
12.7
283 x 800 x 195
9
290 x 1,050 x 238
12
273 x 784 x 195
7.5
290 x 1,050 x 238
12
15.9 15.9
Wall-mounted type
CDKD50CVM
12.0 (424)
37/33/31
CDKD35CVM
10.0 (353)
CDKD60CVM
16.0 (565)
38/34/32
15.9
CDXD25CVMA
9.5 (335)
9.5 (335)
9.5
CDXD35CVMA
10.0 (353)
10.0 (353)
CDXD50CVMA
12.0 (424)
12.0 (424)
37/33/31
37/33/31
CDXD60CVMA
16.0 (565)
16.0 (565)
38/34/32
38/34/32
15.9
CDKD25CVM
9.5 (335)
9.5
Cooling only Heat pump
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
m3/min(cfm)
dB (A)
mm
kg
mm
Pa
12.7 12.7
27 30 27 30
35/31/29
35/31/29
25
35/31/29
25
8.1 (286)
Model name
Power supply
Casing colour
Compressor type
Sound levels
Dimensions (H x W x D)
Machine weight
Operationrange
Max. piping length
Necessity of additional chargeMax. installation height difference
1 phase, 220-240 V, 50 Hz/1 phase, 220-230 V, 60 Hz
White
5 steps, quiet and automatic
Microcomputer control
18.0
Both liquid and gas pipes
Model name
Power supply
Front panel colour
Airflow rates (H)
Sound levels (H/L/SL)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Pipingconnections
Heat insulation
1 phase, 220-240 V, 50 Hz/1 phase, 220-230 V, 60 Hz
5 steps, quiet and automatic
Microcomputer control
6.4
VP20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
Model name
Power supply
Airflow rates (H)
Sound levels (H/L/SL)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Pipingconnections
Heat insulation
External static pressure
3MKD58DVM
45 (total)
48/45 *1
49/46 *1
10 to 46
15 to 15.5
40
*
200 x 900 x 620 200 x 1,100 x 620 200 x 900 x 620 200 x 1,100 x 620
Duct-connected type Cooling only Heat pump
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
m3/min(cfm)
dB(A)
mm
kg
mm
Pa
Figures are subject to change.
Model name
Power supply
Airflow rates (H)
Sound levels (H/L/SL)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Pipingconnections
Heat insulation
External static pressure
*
CDKD25EAVM
9.5
CDKD35EAVM
12.7
CDXD25EAVMA
9.5
8.7 (307)
35/31/29
CDXD35EAVMA
12.7
1 phase, 220-240 V, 50 Hz/1 phase, 220-230 V, 60 Hz
8.7 (307)
35/31/29
5 steps, quiet and automatic
Microcomputer control
200 x 700 x 620
21
6.4
VP20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
35
Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 35 Pa for CDK(X)D-EA and 40 Pa for CDK(X)D-C.Sound level values for bottom-suction operation can be obtained by adding 6 dB for CDK(X)D-EA and 5 dB for CDK(X)D-C.
Figures are subject to change.
Floor/ceiling-suspended dual type
Measurement conditions1. Cooling operation data is based on the following conditions: indoor temp.27CDB,19CWB; outdoor temp.35CDB; piping length 7.5 m.2. Heating operation data is based on the following conditions: indoor temp.20CDB,19CWB; outdoor temp.7CDB, 6CWB; piping length 7.5 m.3. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
FLX25AVMA
7.6 (268)
9.2 (325)
37/31/28
37/31/28
9.5
FLX35AVMA
8.7 (307)
10.0 (353)
38/32/29
39/33/30
FLX50AVMA
11.4 (402)
12.1 (427)
47/39/36
46/35/32
FLX60AVMA
12.0 (424)
12.8 (452)
48/41/38
47/37/34
15.9
Heat pump
FLK25AVMA
7.6 (268)
37/31/28
9.5
FLK35AVMA
8.7 (307)
38/32/29
FLK50AVMA
11.4 (402)
47/39/36
FLK60AVMA
12.0 (424)
48/41/38
15.9
Cooling only
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
m3/min(cfm)
dB (A)
mm
kg
mm 12.712.7
16 1716 17
1 phase, 220-240 V, 50 Hz/1 phase, 220-230 V, 60 Hz
Almond white
5 steps, quiet and automatic
Microcomputer control
490 x 1,050 x 200
6.4
18.0
Both liquid and gas pipes
Model name
Power supply
Front grille colour
Airflow rates (H)
Sound levels (H/L/SL)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Pipingconnections
Heat insulation
OptionsOutdoor units
No.
1
2
Item
Air direction adjustment grille
Drain plug
KPW945A4
Notes:*1. One set includes 5 pieces for 5 units. *2. One set includes 1 piece for 1 unit.
Air directionadjustmentgrill eKPW945A4
DrainplugKKP937A4
2MKD58D 3MKD58D 3MKD75D 3MXD68B 4MKD75D 4MKD100D 4MXD80B
KKP937A4 *1 KKP945A4 *2
Indoor units
No.1
2
3
4
5
6
7
8
9
10
5-room centralised controller*1
Wiring adaptor for time clock/remote controller*2(Normal open pulse contact/normal open contact)
Titanium apatite photocatalytic air-purifying filter*3
Photocatalytic deodorising filter with frame*4
Photocatalytic deodorising filter without frame*4
Air-purifying filter with frame*5
Air-purifying filter without frame*5
Remote controller loss prevention chain
Suction grille
Insulation kit for high humidity
Notes:*1. A wiring adaptor (KRP413A1S) is also required for each indoor unit. *2. Time clock and other devices should be obtained locally. *3. Filter is a standard accessory. It should be replaced after approximately 3 years. *4. The photocatalytic deodorising filter is a standard accessory. It can be reused indefinitely if it is exposed to direct sunlight once every 6 months.
This accessory is only required if the original filter is damaged or lost, etc. *5. The air-purifying filter is a standard accessory. It should be replaced approximately once every 3 months. This accessory is required for the replacement of filters.
Wal l-mounted type Duct-connected type Floor/ceiling-
suspendeddualtypeItem
5-roomcentralisedcontrollerKRC72
Air-purifyingfilter withoutframeKAF970A42
Remote controller l osspreventionchainKKF917A4
System configurations
No.
1
2
3
4
Item
Central remote controller*
Unified on/off controller*
Schedule timer*
Interface adaptor for DIII-NET use
DCS302CA61
DCS301BA61
DST301BA61
KRP928B2S
Note: * A wiring adaptor (KRP928B2S) is also required for each indoor unit.
Wall-mounted type Duct-connected type Floor/ceiling-suspended dual type
Central remote controllerDCS302CA61
Unified on/off controllerDCS301BA61
Schedule timerDST301BA61
FTKD25/35D
KAZ970A42
KAF970A42
FTXE25/35B
KAZ917B41
KAZ917B42
KAF925B41
KAF925B42
FTK(X)D50/60/71F
KAF952B42
CDK(X)D25/35/50C
KDGF19A45
KDT25N50
CDK(X)D25/35EAKRC72
KRP413A1S
KKF917A4
KDT25N32
CDK(X)D60C
KDT25N63
KAZ917B41
KAZ917B42
KAF925B41
KAF925B42
Titaniumapatite photocatalyticair-purifyingfil terKAF952B42
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
13/1423 24
Capacity tables Capacity tables
3MKD58DVM
3MKD75DVM
4MKD75DVM
4MKD100DVM
Combinationsof indoor units
Outdoorunit
Total capacity (kW)Rated (Min._Max.)
Total power consumption (W)Rated (Min._Max.)
Total current (A)Rated (Min._Max.)
Capacity of each indoor unit (kW)
A room B room C room D roomA room B room C room D room
4MKD75DVM
2MKD58DVM
Combinations
of indoor units
Outdoor
unit
Total capacity (kW)Rated (Min._Max.)
Total power consumption (W)Rated (Min._Max.)
Total current (A)Rated (Min._Max.)
Capacity of each indoor unit (kW)
Cooling only type 220 V, 50/60 Hz
25
35
50
25+25
25+35
25+50
35+35
35+50
50+50
25+25+25
25+25+35
25+25+50
25+35+35
2.50 (1.523.34)
3.50 (1.614.14)
5.00 (1.685.70)
5.00 (1.686.30)
5.80 (1.816.61)
5.80 (2.006.71)
5.80 (1.936.69)
5.80 (2.156.79)
5.80 (2.376.90)
5.79 (2.006.75)
5.80 (2.156.80)
5.80 (2.376.90)
5.80 (2.306.86)
810 (4501,090)
1,240 (4701,570)
1,710 (5402,140)
1,600 (4802,290)
2,050 (5002,390)
1,840 (5702,340)
2,010 (5402,390)
1,810 (6202,350)
1,620 (6202,120)
1,700 (5302,170)
1,690 (5802,170)
1,530 (5901,960)
1,670 (6202,190)
4.1 (2.2 5.4)
5.9 (2.3 7.6)
7.9 (2.5 9.9)
7.4 (2.210.6)
9.4 (2.311.1)
8.5 (2.610.8)
9.3 (2.511.1)
8.3 (2.910.9)
7.5 (2.9 9.8)
7.8 (2.410.0)
7.8 (2.710.1)
7.1 (2.7 9.0)
7.7 (2.910.1)
25
35
50
25+25
25+35
25+50
35+35
35+50
50+50
2.50 (1.523.34)
3.50 (1.614.14)
5.00 (1.685.70)
5.00 (1.686.30)
5.80 (1.816.61)
5.80 (2.006.71)
5.80 (1.936.69)
5.80 (2.156.79)
5.80 (2.376.90)
810 (4501,090)
1,240 (4701,570)
1,710 (5402,140)
1,600 (4802,290)
2,050 (5002,390)
1,840 (5702,340)
2,010 (5402,390)
1,810 (6202,350)
1,620 (6202,120)
4.1 (2.2 5.4)
5.9 (2.3 7.6)
7.9 (2.5 9.9)
7.4 (2.210.6)
9.4 (2.311.1)
8.5 (2.610.8)
9.3 (2.511.1)
8.3 (2.910.9)
7.5 (2.9 9.8)
25
35
50
60
71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+60
35+71
50+50
50+60
50+71
60+60
60+71
25+25+25
25+25+35
25+25+50
25+25+60
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
35+35+35
35+35+50
35+35+60
35+50+50
2.50 (1.603.35)
3.50 (1.694.15)
5.00 (1.775.80)
6.00 (1.906.45)
7.10 (2.057.19)
5.00 (1.776.30)
6.00 (1.906.70)
7.10 (2.117.28)
7.20 (2.267.62)
7.50 (2.437.98)
7.00 (2.037.20)
7.20 (2.267.70)
7.50 (2.427.93)
7.50 (2.598.23)
7.50 (2.498.08)
7.50 (2.668.31)
7.50 (2.878.49)
7.50 (2.858.47)
7.50 (3.068.57)
6.90 (2.117.61)
7.20 (2.267.77)
7.50 (2.498.18)
7.50 (2.668.32)
7.50 (2.878.52)
7.50 (2.427.99)
7.50 (2.668.32)
7.50 (2.858.50)
7.50 (3.068.70)
7.50 (2.948.60)
7.50 (3.148.75)
7.50 (2.588.25)
7.50 (2.858.51)
7.50 (3.048.65)
7.50 (3.148.75)
780 (4701,100)
1,260 (4901,530)
1,680 (5702,040)
2,280 (5902,560)
2,910 (6203,000)
1,590 (5002,370)
2,180 (5202,620)
2,550 (6002,710)
2,570 (6402,960)
2,740 (6803,150)
2,760 (5702,950)
2,570 (6503,020)
2,760 (6803,060)
2,730 (7403,260)
2,590 (6503,090)
2,560 (6803,150)
2,540 (7503,430)
2,550 (7503,380)
2,520 (8003,490)
2,210 (5702,670)
2,390 (6102,810)
2,440 (6202,870)
2,410 (6602,950)
2,400 (7203,110)
2,490 (6502,980)
2,410 (6602,990)
2,400 (7003,050)
2,360 (7603,260)
2,380 (6702,970)
2,310 (7303,080)
2,510 (7003,110)
2,400 (7303,140)
2,370 (7603,260)
2,270 (7303,030)
3.9 (2.4 5.5)
6.0 (2.4 7.4)
7.8 (2.6 9.4)
10.5 (2.711.8)
13.4 (2.913.8)
7.4 (2.410.9)
10.1 (2.412.0)
11.8 (2.812.5)
11.8 (3.013.6)
12.6 (3.114.5)
12.7 (2.613.6)
11.8 (3.013.9)
12.7 (3.114.1)
12.6 (3.515.0)
11.9 (3.014.3)
11.8 (3.114.5)
11.7 (3.515.8)
11.8 (3.515.6)
11.6 (3.716.1)
10.3 (2.612.3)
11.0 (2.813.0)
11.3 (2.913.2)
11.1 (3.013.6)
11.1 (3.414.4)
11.5 (3.013.7)
11.1 (3.013.7)
11.1 (3.214.1)
10.9 (3.615.0)
11.0 (3.113.7)
10.7 (3.414.2)
11.6 (3.214.4)
11.1 (3.414.5)
10.9 (3.615.0)
10.5 (3.414.0)25
35
50
60
71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+60
35+71
50+50
50+60
50+71
60+60
60+71
25+25+25
25+25+35
25+25+50
25+25+60
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
35+35+35
35+35+50
35+35+60
35+50+50
25+25+25+25
25+25+25+35
25+25+25+50
25+25+25+60
25+25+35+35
25+25+35+50
25+35+35+35
2.50 (1.603.35)
3.50 (1.694.15)
5.00 (1.775.80)
6.00 (1.906.45)
7.10 (2.057.19)
5.00 (1.776.30)
6.00 (1.906.70)
7.10 (2.117.28)
7.20 (2.267.62)
7.50 (2.437.98)
7.00 (2.037.20)
7.20 (2.267.70)
7.50 (2.427.93)
7.50 (2.598.23)
7.50 (2.498.08)
7.50 (2.668.31)
7.50 (2.878.49)
7.50 (2.858.47)
7.50 (3.068.57)
6.90 (2.11 7.61)
7.20 (2.26 7.77)
7.50 (2.49 8.18)
7.50 (2.66 8.32)
7.50 (2.87 8.52)
7.50 (2.42 7.99)
7.50 (2.66 8.32)
7.50 (2.85 8.50)
7.50 (3.06 8.70)
7.50 (2.94 8.60)
7.50 (3.14 8.75)
7.50 (2.58 8.25)
7.50 (2.85 8.51)
7.50 (3.04 8.65)
7.50 (3.14 8.75)
7.48 (2.49 8.34)
7.50 (2.66 8.50)
7.50 (2.94 8.69)
7.50 (3.14 8.80)
7.50 (2.85 8.62)
7.50 (3.14 8.80)
7.50 (3.04 8.75)
780 (4701,100)
1,260 (4901,530)
1,680 (5702,040)
2,280 (5902,560)
2,910 (6203,000)
1,590 (5002,370)
2,180 (5202,620)
2,550 (6002,710)
2,570 (6402,960)
2,740 (6803,150)
2,760 (5702,950)
2,570 (6503,020)
2,760 (6803,060)
2,730 (7403,260)
2,590 (6503,090)
2,560 (6803,150)
2,540 (7503,430)
2,550 (7503,380)
2,520 (8003,490)
2,210 (5702,670)
2,390 (6102,810)
2,440 (6202,870)
2,410 (6602,950)
2,400 (7203,110)
2,490 (6502,980)
2,410 (6602,990)
2,400 (7003,050)
2,360 (7603,260)
2,380 (6702,970)
2,310 (7303,080)
2,510 (7003,110)
2,400 (7303,140)
2,370 (7603,260)
2,270 (7303,030)
2,290 (5902,930)
2,270 (6303,080)
2,240 (6503,110)
2,220 (6903,220)
2,250 (6703,180)
2,230 (6903,220)
2,240 (7303,290)
3.9 (2.4 5.5)
6.0 (2.4 7.4)
7.8 (2.6 9.4)
10.5 (2.711.8)
13.4 (2.913.8)
7.4 (2.410.9)
10.1 (2.412.0)
11.8 (2.812.5)
11.8 (3.013.6)
12.6 (3.114.5)
12.7 (2.613.6)
11.8 (3.013.9)
12.7 (3.114.1)
12.6 (3.515.0)
11.9 (3.014.3)
11.8 (3.114.5)
11.7 (3.515.8)
11.8 (3.515.6)
11.6 (3.716.1)
10.3 (2.612.3)
11.0 (2.813.0)
11.3 (2.913.2)
11.1 (3.013.6)
11.1 (3.414.4)
11.5 (3.013.7)
11.1 (3.013.7)
11.1 (3.214.1)
10.9 (3.615.0)
11.0 (3.113.7)
10.7 (3.414.2)
11.6 (3.214.4)
11.1 (3.414.5)
10.9 (3.615.0)
10.5 (3.414.0)
10.6 (2.713.5)
10.5 (2.914.2)
10.3 (3.014.4)
10.2 (3.214.8)
10.4 (3.114.7)
10.3 (3.214.8)
10.3 (3.415.1)
2.50
3.50
5.00
2.50
2.50
2.37
2.12
1.95
3.50
2.96
2.76
2.48
3.75
3.41
3.10
2.30
2.12
1.88
1.70
1.55
1.98
1.70
1.56
1.43
1.50
1.39
2.50
2.19
2.02
1.94
1.87
1.70
1.50
1.39
1.56
1.39
1.44
2.50
3.50
4.73
3.50
4.24
3.75
2.30
2.12
1.88
1.70
1.55
2.76
2.39
2.19
2.00
3.00
2.78
2.50
2.19
2.02
2.78
1.87
1.70
1.50
1.39
1.56
1.39
2.02
6.00
7.10
5.08
5.55
4.74
5.02
4.09
4.40
3.75
3.44
2.30
2.96
3.74
4.10
4.40
2.76
3.41
3.75
4.07
3.00
3.33
2.50
3.12
3.46
2.78
1.87
1.70
1.50
1.39
2.19
1.94
2.02
3.75
4.06
1.87
2.40
3.00
3.33
2.19
2.78
2.02
2.50
3.50
5.00
2.50
2.42
1.93
2.90
2.39
2.90
2.50
3.38
3.87
2.90
3.41
2.90
2.50
3.505.00
2.50
2.42
1.93
2.90
2.39
2.90
1.93
1.71
1.45
1.52
2.50
3.38
3.87
2.90
3.41
2.90
1.93
1.71
1.45
2.14
1.93
2.38
2.90
2.14
2.50
3.50
5.00
2.50
2.50
2.37
2.12
1.95
3.50
2.96
2.76
2.48
3.75
3.41
3.10
2.30
2.12
1.88
1.70
1.55
1.98
1.70
1.56
1.43
1.50
1.39
2.50
2.19
2.02
1.94
6.00
7.10
2.50
3.50
4.73
5.08
5.55
3.50
4.24
4.74
5.02
3.75
4.09
4.40
3.75
3.44
2.30
2.12
1.88
1.70
1.55
2.76
2.39
2.19
2.00
3.00
2.78
2.50
2.19
2.02
2.78
3.75
4.06
2.30
2.96
3.74
4.10
4.40
2.76
3.41
3.75
4.07
3.00
3.33
2.50
3.12
3.46
2.78
25
35
50
60
71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+60
35+71
50+50
50+60
50+71
60+60
60+71
71+71
25+25+25
25+25+35
25+25+50
25+25+60
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
25+50+71
25+60+60
25+60+7135+35+35
35+35+50
35+35+60
35+35+71
35+50+50
35+50+60
35+50+71
35+60+60
50+50+50
2.50 (1.95 3.60)
3.50 (2.05 4.50)
5.00 (2.20 6.20)
6.00 (2.30 6.70)
7.10 (2.41 7.20)
5.00 (2.20 6.70)
6.00 (2.30 7.00)
7.50 (2.45 8.20)
7.60 (2.55 8.60)
7.63 (2.66 8.80)
7.00 (2.40 7.70)
7.55 (2.55 8.50)
7.65 (2.65 8.70)
8.04 (2.76 9.25)
7.78 (2.70 9.00)
8.22 (2.80 9.50)
8.71 (2.91 9.60)
8.68 (2.90 9.70)
9.16 (3.01 9.80)
9.64 (3.12 9.90)
7.50 (2.45 8.40)
7.60 (2.55 8.60)
7.78 (2.70 9.20)
8.22 (2.80 9.70)
8.71 (2.91 9.75)
7.90 (2.65 9.00)
8.22 (2.80 9.70)
8.67 (2.90 9.75)
9.16 (3.01 9.95)
8.89 (2.95 9.80)
9.33 (3.0510.00)
9.82 (3.1610.35)
9.78 (3.1510.30)
10.00 (3.2610.45)8.10 (2.75 9.30)
8.67 (2.90 9.75)
9.11 (3.00 9.95)
9.60 (3.1110.30)
9.33 (3.0510.20)
9.78 (3.1510.30)
10.00 (3.2610.45)
10.00 (3.2510.40)
9.96 (3.2010.35)
660 (5101,050)
1,050 (5401,530)
1,660 (5402,490)
1,950 (5302,310)
2,700 (5602,760)
1,470 (5202,510)
2,090 (5402,820)
2,920 (5503,460)
2,800 (5403,070)
2,470 (5703,270)
3,080 (5703,790)
3,180 (5703,900)
2,420 (5603,170)
2,800 (5903,810)
2,660 (5803,640)
2,580 (5803,440)
2,960 (6003,540)
2,620 (5803,190)
2,980 (6003,280)
3,250 (6303,370)
2,520 (5303,100)
2,800 (5503,320)
2,380 (5603,340)
2,400 (5603,300)
2,720 (5903,350)
2,860 (5803,820)
2,700 (5903,920)
2,700 (5803,350)
3,080 (6103,550)
2,910 (6003,470)
3,010 (6003,330)
3,310 (6303,470)
3,340 (6103,540)
3,490 (6403,700)2,960 (6003,820)
3,090 (6103,980)
3,040 (6103,550)
3,500 (6303,940)
3,300 (6203,910)
3,410 (6303,820)
3,580 (6503,780)
3,470 (6403,750)
3,450 (6403,760)
3.1 (2.4 5.0)
5.0 (2.6 7.2)
7.9 (2.611.8)
9.2 (2.510.9)
12.4 (2.612.7)
6.7 (2.411.5)
9.6 (2.512.9)
13.4 (2.515.9)
12.9 (2.514.1)
11.3 (2.615.0)
14.1 (2.617.4)
14.6 (2.617.9)
11.1 (2.614.6)
12.9 (2.717.5)
12.2 (2.716.7)
11.8 (2.715.8)
13.6 (2.816.3)
12.0 (2.714.6)
13.7 (2.815.1)
14.9 (2.915.5)
11.6 (2.414.2)
12.9 (2.515.2)
10.9 (2.615.3)
11.0 (2.615.2)
12.5 (2.715.4)
13.1 (2.717.5)
12.4 (2.718.0)
12.4 (2.715.4)
14.1 (2.816.3)
13.4 (2.815.9)
13.8 (2.815.3)
15.2 (2.915.9)
15.3 (2.816.3)
16.0 (2.917.0)13.6 (2.817.5)
14.2 (2.818.3)
14.0 (2.816.3)
16.1 (2.918.1)
15.2 (2.818.0)
15.7 (2.917.5)
16.4 (3.017.4)
15.9 (2.917.2)
15.8 (2.917.3)
2.50
3.50
5.00
2.50
2.50
2.50
2.24
1.99
3.50
3.11
2.82
2.66
3.89
3.74
3.60
2.50
2.23
1.95
1.87
2.18
2.08
1.87
1.81
1.74
1.77
1.74
1.68
1.70
1.602.70
2.53
2.46
2.38
2.43
2.36
2.10
2.26
3.32
2.50
3.50
5.00
5.36
5.64
3.50
4.44
4.83
5.38
3.89
4.48
5.11
4.34
4.19
4.82
2.50
2.23
1.95
1.87
2.18
2.91
2.62
2.53
2.45
3.56
3.45
3.37
4.04
3.602.70
2.53
2.46
2.38
3.45
3.38
3.00
3.87
3.32
6.00
7.10
4.34
4.97
4.82
2.50
3.14
3.88
4.48
4.35
2.91
3.73
4.33
4.97
3.56
4.14
4.77
4.04
4.802.70
3.61
4.19
4.84
3.45
4.04
4.90
3.87
3.3225+25+25+25
25+25+25+35
25+25+25+50
25+25+25+60
25+25+25+71
25+25+35+35
25+25+35+50
25+25+35+60
25+25+35+71
25+25+50+50
7.80 (2.70 9.45)
8.22 (2.80 9.70)
8.89 (2.9510.10)
9.33 (3.0510.20)
9.82 (3.1610.30)
8.66 (2.90 9.90)
9.34 (3.0510.25)
9.77 (3.1510.40)
10.00 (3.2610.50)
9.96 (3.2010.45)
2,210 (5503,220)
2,480 (5703,460)
2,740 (5903,510)
2,950 (6003,540)
3,370 (6203,740)
2,800 (5903,460)
3,080 (6103,760)
3,340 (6203,790)
3,330 (6403,740)
3,470 (6303,760)
10.1 (2.514.8)
11.4 (2.615.9)
12.6 (2.716.1)
13.5 (2.816.3)
15.5 (2.817.2)
12.9 (2.715.9)
14.1 (2.817.3)
15.3 (2.817.4)
15.3 (2.917.2)
15.9 (2.917.3)
1.95
1.86
1.78
1.73
1.68
1.80
1.73
1.68
1.70
1.66
1.95
1.86
1.78
1.73
1.68
1.80
1.73
1.68
1.70
1.66
1.95
1.86
1.78
1.73
1.68
2.53
2.42
2.36
2.30
3.32
1.95
2.64
3.55
4.14
4.78
2.53
3.46
4.05
4.30
3.32
-
8/2/2019 Daikin PCR0720 - Super Multi NX [Small]
14/1425 26
Capacity tables Capacity tables
3MXD68BVMA
Coolingcapacity
4MXD80BVMA
Coolingcapacity
Combinationsof indoor units
Outdoorunit
A r oo m B r oo m C r oom
Total capacity (kW)Rated (Min._Max.)
Total power consumption (W)Rated (Min._Max.)
Total current (A)Rated (Min._Max.)
Capacity of each indoor unit (kW)
3MXD68BVMA
Heatingcapacity
D room
Heat pump type 220 V, 50/60 Hz
25
35
50
60
25+25
25+35
25+50
25+60
35+35
35+50
35+60
50+50
50+60
25+25+25
25+25+35
25+25+50
25+25+60
25+35+35
25+35+50
35+35+35
2.50
3.50
5.00
2.50
2.42
2.08
1.88
3.00
2.64
2.42
3.32
3.09
2.08
1.88
1.66
1.55
1.78
1.55
2.26
2.50
3.38
4.16
3.00
3.76
3.32
2.08
1.88
1.66
1.55
2.51
2.16
2.26
6.00
4.52
4.14
3.71
2.08
2.64
3.32
3.70
2.51
3.09
2.26
2.50 (1.583.02)
3.50 (1.673.92)
5.00 (1.755.22)
6.00 (1.886.16)
5.00 (1.755.31)
5.80 (1.886.24)
6.24 (2.096.64)
6.40 (2.246.78)
6.00 (2.016.45)
6.40 (2.246.78)
6.56 (2.407.05)
6.64 (2.477.21)
6.80 (2.637.27)
6.24 (2.096.94)
6.40 (2.246.99)
6.64 (2.477.26)
6.80 (2.637.41)
6.80 (2.407.23)
6.80 (2.637.41)
6.78 (2.557.38)
830 (4401,150)
1,250 (4601,530)
1,810 (5301,920)
2,700 (5602,970)
1,710 (4701,940)
2,290 (5002,720)
2,090 (5602,380)
2,220 (6002,520)
2,430 (5302,720)
2,260 (6102,560)
2,390 (6402,760)
2,100 (6102,380)
2,190 (6402,380)
1,860 (5302,360)
1,980 (5702,410)
1,940 (5802,360)
2,110 (6202,610)
2,170 (6102,680)
2,110 (6202,610)
2,150 (6602,780)
3.9 (2.1 5.4)
5.8 (2.1 7.1)
8.3 (2.4 8.8)
12.4 (2.613.6)
7.9 (2.2 8.9)
10.5 (2.312.5)
9.6 (2.610.9)
10.2 (2.811.6)
11.2 (2.412.5)
10.4 (2.811.8)
11.0 (2.912.7)
9.6 (2.810.9)
10.1 (2.910.9)
8.5 (2.410.8)
9.1 (2.611.1)
8.9 (2.710.8)
9.7 (2.812.0)
10.0 (2.812.3)
9.7 (2.812.0)
9.9 (3.012.8)
2535
50
60
71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+60
35+71
50+50
50+60
50+71
60+60
60+71
25+25+25
2.50
2.50
2.50
2.40
2.18
1.98
3.50
3.06
2.40
3.50
5.00
2.50
3.50
4.79
3.50
4.36
2.77
2.52
3.79
3.64
3.31
2.40
6.00
7.10
5.24
5.62
4.75
5.10
3.79
4.36
4.69
4.00
3.66
2.40
4.00
4.34
2.50 (1.583.30)3.50 (1.674.11)
5.00 (1.755.87)
6.00 (1.886.43)
7.10 (2.037.14)
5.00 (1.756.16)
6.00 (1.886.59)
7.19 (2.097.29)
7.42 (2.237.82)
7.60 (2.408.04)
7.00 (2.017.19)
7.42 (2.237.82)
7.52 (2.398.02)
7.62 (2.578.32)
7.58 (2.478.31)
8.00 (2.648.41)
8.00 (2.848.44)
8.00 (2.828.49)
8.00 (3.038.46)
7.20 (2.097.53)
750 (4501,040)1,210 (4701,480)
1,640 (5402,190)
2,240 (5602,600)
2,800 (5903,160)
1,560 (4802,260)
2,140 (5002,690)
2,460 (5702,730)
2,590 (6003,140)
2,740 (6503,470)
2,530 (5403,060)
2,550 (6103,300)
2,660 (6503,310)
2,830 (7003,600)
2,630 (6203,240)
2,850 (6603,230)
2,670 (7103,420)
2,680 (7103,310)
2,650 (7603,410)
2,600 (5402,760)
3.9 (2.4 5.4)5.8 (2.2 7.1)
7.6 (2.510.2)
10.4 (2.612.1)
12.9 (2.714.5)
7.2 (2.210.5)
10.0 (2.312.6)
11.3 (2.612.5)
11.9 (2.814.4)
12.6 (3.015.9)
11.6 (2.514.0)
11.7 (2.815.2)
12.2 (3.015.2)
13.0 (3.216.5)
12.1 (2.814.9)
13.1 (3.014.8)
12.3 (3.315.7)
12.3 (3.315.2)
12.2 (3.515.7)
11.9 (2.512.7)
25
35
50
60
25+25
25+35
25+50
25+60
35+35
35+50
35+60
50+50
50+60
25+25+25
25+25+35
25+25+50
25+25+60
25+35+35
25+35+50
35+35+35
3.86
4.42
6.13
3.55
3.18
2.83
2.53
4.00
3.54
3.17
4.30
3.91
2.86
2.53
2.15
1.95
2.26
1.95
2.86
3.55
4.45
5.67
4.00
5.06
4.30
2.86
2.53
2.15
1.95
3.17
2.74
2.86
7.32
6.07
5.43
4.69
2.86
3.54
4.30
4.70
3.17
3.91
2.86
3.86 (1.464.75)
4.42 (1.615.40)
6.13 (1.847.40)
7.32 (2.008.35)
7.10 (2.147.95)
7.63 (2.268.40)
8.50 (2.448.87)
8.60 (2.559.15)
8.00 (2.388.55)
8.60 (2.559.15)
8.60 (2.689.25)
8.60 (2.749.45)
8.60 (2.869.55)
8.58 (2.809.40)
8.60 (2.959.41)
8.60 (3.189.55)
8.60 (3.339.60)
8.60 (3.109.45)
8.60 (3.339.60)
8.58 (3.259.55)
1,340 (4801,730)
1,630 (5402,130)
2,050 (4602,820)
2,650 (4803,320)
2,340 (5203,030)
2,610 (5503,330)
2,830 (5403,060)
2,840 (5603,110)
2,830 (5703,240)
2,870 (5603,150)
2,790 (5803,130)
2,460 (5502,880)
2,400 (5702,870)
2,760 (6203,170)
2,610 (6503,170)
2,430 (6402,850)
2,410 (6702,820)
2,520 (6803,170)
2,380 (6702,860)
2,410 (7303,070)
6.2 (2.2 8.0)
7.5 (2.5 9.8)
9.4 (2.112.9)
12.2 (2.215.2)
10.7 (2.413.9)
12.0 (2.515.3)
13.0 (2.514.0)
13.0 (2.614.3)
13.0 (2.614.9)
13.2 (2.614.5)
12.8 (2.714.4)
11.3 (2.513.2)
11.0 (2.613.2)
12.7 (2.814.6)
12.0 (3.014.6)
11.2 (2.913.1)
11.1 (3.112.9)
11.6 (3.114.6)
10.9 (3.113.1)
11.1 (3.414.1)
A room B room C room D room
4MKD100DVM
Combinationsof indoor units
Outdoorunit
Total capacity (kW)Rated (Min._Max.)
Total power consumption (W)Rated (Min._Max.)
Total current (A)Rated (Min._Max.)
Capacity of each indoor unit (kW)
25+35+35+35
25+35+35+50
25+35+35+60
35+35+35+35
35+35+35+50
9.10 (3.0010.00)
9.78 (3.1510.30)
10.00 (3.2510.40)
9.56 (3.1010.10)
10.00 (3.2510.40)
3,170 (6103,670)
3,490 (6303,710)
3,450 (6403,750)
3,630 (6403,900)
3,640 (6503,820)
14.6 (2.816.9)
16.0 (2.917.0)
15.8 (2.917.2)
16.7 (2.917.9)
16.7 (3.017.5)
1.75
1.68
1.61
2.39
2.26
2.45
2.36
2.26
2.39
2.26
2.45
2.36
2.26
2.39
2.26
2.45
3.38
3.87
2.39
3.22
Notes:1. Data is based on the following conditions: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB. 2. Total capacity of connected indoor units is: up to 10.0 kW to the 2/3MKD58D; up to 13.5 kW to the 3/4MKD75D; up to 15.6 kW to the 4MKD100D.
4MXD80BVMA
Coolingcapacity
Combinationsof indoor units
Outdoorunit
A r oo m B r oo m C r oom
Total capacity (kW)Rated (Min._Max.)
Total power consumption (W)Rated (Min._Max.)
Total current (A)Rated (Min._Max.)
Capacity of each indoor unit (kW)
D room
Heat pump type 220 V, 50/60 Hz
25+25+35
25+25+50
25+25+60
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
35+35+35
35+35+50
35+35+60
35+50+50
2.18
1.94
1.82
1.65
2.01
1.82
1.67
1.53
1.60
1.48
2.63
2.34
2.15
2.08
2.18
1.94
1.82
1.65
2.82
2.55
2.33
2.14
3.20
2.96
2.63
2.33
2.15
2.96
3.06
3.89
4.36
4.70
2.82
3.63
4.00
4.33
3.20
3.56
2.63
3.33
3.70
2.96
7.42 (2.237.92)
7.77 (2.478.17)
8.00 (2.648.61)
8.00 (2.848.66)
7.65 (2.398.02)
8.00 (2.648.61)
8.00 (2.828.64)
8.00 (3.038.73)
8.00 (2.918.67)
8.00 (3.118.85)
7.89 (2.568.22)
8.00 (2.828.64)
8.00 (3.018.82)
8.00 (3.119.10)
2,610 (5803,060)
2,640 (5902,950)
2,800 (6303,170)
2,640 (6803,340)
2,670 (6203,130)
2,730 (6303,170)
2,660 (6703,160)
2,590 (7203,400)
2,550 (6403,220)
2,490 (6903,220)
2,740 (6703,230)
2,650 (6803,240)
2,610 (7203,240)
2,510 (6903,290)
12.0 (2.714.0)
12.1 (2.713.5)
12.9 (2.914.6)
12.1 (3.115.3)
12.3 (2.814.4)
12.5 (2.914.6)
12.2 (3.114.5)
11.9 (3.315.6)
11.7 (2.914.8)
11.4 (3.214.8)
12.6 (3.114.8)
12.2 (3.114.9)
12.0 (3.314.9)
11.5 (3.215.1)
4MXD80BVMA
Heatingcapacity
25+25+25+25
25+25+25+35
25+25+25+50
25+25+25+60
25+25+35+35
25+25+35+50
25+35+35+35
1.94
1.82
1.60
1.48
1.67
1.48
1.55
1.94
1.82
1.60
1.48
1.67
1.48
2.15
1.94
1.82
1.60
1.48
2.33
2.07
2.15
1.94
2.54
3.20
3.56
2.33
2.97
2.15
7.76 (2.478.41)
8.00 (2.648.61)
8.00 (2.919.10)
8.00 (3.119.19)
8.00 (2.828.90)
8.00 (3.119.19)
8.00 (3.019.14)
2,630 (5602,910)
2,780 (6003,080)
2,560 (6203,220)
2,410 (6603,270)
2,580 (6403,370)
2,420 (6603,290)
2,470 (6903,460)
12.1 (2.613.4)
12.8 (2.814.1)
11.9 (2.914.9)
11.2 (3.115.2)
11.8 (2.915.5)
11.1 (3.015.1)
11.3 (3.215.9)
25
35
50
60
71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+6035+71
50+50
50+60
50+71
60+60
60+71
25+25+25
25+25+35
25+25+50
25+25+60
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
35+35+35
35+35+50
35+35+60
35+50+50
25+25+25+2525+25+25+35
25+25+25+50
25+25+25+60
25+25+35+35
25+25+35+50
25+35+35+35
3.86
3.55
3.18
2.88
2.62
2.40
4.13
3.66
2.88
2.62
2.33
2.18
1.98
2.52
2.18
2.00
1.83
1.92
1.78
3.16
2.80
2.58
2.48
2.332.18
1.92
1.78
2.00
1.78
1.86
4.42
6.13
3.55
4.45
5.75
4.13
5.24
3.393.13
4.67
4.36
3.97
2.88
2.62
2.33
2.18
1.98
3.38
3.05
2.80
2.56
3.84
3.56
3.16
2.80
2.58
3.56
2.332.18
1.92
1.78
2.00
1.78
2.58
7.32
8.31
6.28
6.82
5.806.36
4.67
5.24
5.63
4.80
4.40
2.88
3.96
4.66
5.24
5.64
3.38
4.37
4.80
5.21
3.84
4.26
3.16
4.00
4.44
3.56
2.332.18
1.92
1.78
2.80
2.49
2.58
4.80
5.20
2.333.06
3.84
4.26
2.80
3.55
2.58
3.86 (1.47 4.81)
4.42 (1.63 5.00)
6.13 (1.86 8.19)
7.32 (2.02 8.79)
8.31 (2.19 9.45)
7.10 (2.16 9.40)
7.63 (2.28 9.58)
8.63 (2.4610.35)
8.90 (2.5810.39)
9.22 (2.7210.44)
8.26 (2.40 9.81)
8.90 (2.5810.39)
9.19 (2.7110.43)9.49 (2.8410.48)
9.34 (2.7710.47)
9.60 (2.8910.49)
9.60 (3.0210.54)
9.60 (3.0110.52)
9.60 (3.1410.58)
8.64 (2.8310.40)
8.90 (2.9810.47)
9.32 (3.2110.56)
9.60 (3.3610.63)
9.60 (3.5210.70)
9.18 (3.1310.53)
9.60 (3.3610.63)
9.60 (3.5110.69)
9.60 (3.6710.76)
9.60 (3.5810.73)
9.60 (3.7310.79)
9.47 (3.2810.60)
9.60 (3.5110.69)
9.60 (3.6610.76)
9.60 (3.7310.79)
9.31 (3.5410.57)9.60 (3.7210.63)
9.60 (4.0010.73)
9.60 (4.1910.79)
9.60 (3.9110.70)
9.60 (4.1910.80)
9.60 (4.0910.76)
1,320 (4401,990)
1,590 (4902,110)
1,620 (4202,930)
2,170 (4403,290)
2,740 (4803,660)
1,900 (4703,440)
2,160 (5003,470)
2,470 (4903,470)
2,600 (5103,460)
2,620 (5303,280)
2,530 (5203,590)
2,600 (5103,480)
2,610 (5303,270)2,630 (5503,160)
2,620 (5003,310)
2,640 (5203,170)
2,590 (5403,120)
2,590 (5403,110)
2,550 (5603,110)
2,410 (5603,430)
2,590 (5903,470)
2,590 (5803,340)
2,600 (6103,140)
2,540 (6303,130)
2,590 (6203,320)
2,600 (6103,160)
2,550 (6303,100)
2,470 (6702,990)
2,510 (6003,150)
2,450 (6203,040)
2,600 (6603,160)
2,550 (6403,110)
2,490 (6703,010)
2,450 (6303,010)
2,410 (6403,130)2,460 (6803,020)
2,420 (6703,060)
2,400 (7103,010)
2,430 (7203,000)
2,400 (7102,980)
2,410 (7602,990)
6.2 (2.1 9.3)
7.4 (2.3 9.8)
7.4 (1.913.5)
10.0 (2.015.1)
12.6 (2.216.8)
8.7 (2.215.8)
9.9 (2.315.9)
11.3 (2.215.9)
11.9 (2.315.9)
12.0 (2.415.1)
11.6 (2.416.5)
11.9 (2.316.0)
12.0 (2.415.0)12.1 (2.514.5)
12.0 (2.315.2)
12.1 (2.414.6)
11.9 (2.514.3)
11.9 (2.514.3)
11.7 (2.614.3)
11.1 (2.615.7)
11.9 (2.715.9)
11.9 (2.715.3)
11.9 (2.814.4)
11.7 (2.914.4)
11.9 (2.815.2)
11.9 (2.814.5)
11.7 (2.914.2)
11.3 (3.113.7)
11.5 (2.814.5)
11.2 (2.814.0)
11.9 (3.014.5)
11.7 (2.914.3)
11.4 (3.113.8)
11.2 (2.913.8)
11.1 (2.914.4)11.3 (3.113.9)
11.1 (3.114.0)
11.0 (3.313.8)
11.2 (3.313.8)
11.0 (3.313.7)
11.1 (3.513.7)
Notes:1. Cooling operation data is based on the following conditions: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB. 2. Heating operation data is based on the following conditions: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB. 3. The total capacity of connected indoor units to the 3MXD68B is up to 11.0 kW, and to the 4MXD80B is up to 13.5 kW. 4. A single indoor unit cannot be connected.