DAIKIN ALTHERMA 11-16kW ERLQ…CA: the heatpump for heating and
domestic hot water preparation in severe winter conditions
High capacity at low ambient
Increased operation range
High efficient defrost
High efficient domestic hot water production
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
outdoor unit indoor units
heat emissionheat generation
OPTIONAL DHW tank
* Nominal heating capacity at Ta=7°C / EWC=30°C / LWC=35°C
** Nominal cooling capacity at Ta=35°C / EWC=23°C / LWC=18°C
( cooling function is only available in combination with reversible type hydrobox
These models will replace all previous ERLQ---BA models
11.2kW* 16kW*
15.0kW** 16.8kW**
14kW*
16.1kW**
ERLQ011CAV3ERLQ014CAV3ERLQ016CAV3
1P230V
3P400V
HeatingCooling
Heatingonly
16kW*
Wall hang Floor standing‘integrated design’
EKHB EKHV
Enamel / Stainless steelStainless steel
‘integrated design’
150 – 200 – 300 L 200 – 260 L
EKHW EKHTERLQ011CAW1ERLQ014CAW1ERLQ016CAW1
concept explanation
Layout of the product
layout
UFH
HP convector
NEW
OROR
▪ extended operation range on 1-phase units▪ improved efficiency of DHW-production
2 - Avoid blockage of bottom plate
▪ increase holes in bottom frame▪ improve bottom plate heater (smaller capacity, intelligent control)
3 - Avoid ice accumulation
▪ remove grid from side plate▪ software update
▪ development of snowcover option
▪ hot gas defrosting
▪ adding sub cool pass
▪ increased capacity at low ambient conditions
1 - Improve performance
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
Outdoor T (°C)
product features
improved capacity operation range domestic hot water cold ambient
Improved capacity
Higher compressor frequency improved capacity compared to previous model
new model ERLQ016CAW1 compared to previous ERLQ016BAW1 installed in a 14kW house at Vienna, Austria.
Less need of backup heater=
higher system COP
Integrated CO
P
Less BUH support needed!
Example
HP and system capacity are higher at low ambient temperatures.
ERLQ016CERLQ016B
ERLQ016CERLQ016B
1/2
+2 kW @ -15°C
Increased heating capacity
NO BUH support needed!
Therm
al o
utp
ut
(kW
h/C
°)
Outdoor T (°C)
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
product features
improved capacity operation range domestic hot water cold ambient
Improved capacity
Higher compressor frequency improved capacity compared to previous model
2/2
Changes in piping diagram
HIGH PRESSURE SIDE
LOW PRESSURE SIDE
HEATING CYCLE
Daikin scroll compressor
Animation of Daikin scroll compressor operation
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
Design improvements to increase operation range: EEV injection
product features
improved capacity operation range domestic hot water cold ambient
Tlw
Ta
25 40 55
-25
0
35
-20
Ta
25 40 55
-25
0
35
-20
Previous single phase ERLQ unit New ERLQ unit
( single and 3phase)
Max. leaving water temp. is independent of the ambient temp.Compressor operation till -25°C
EXTENDED OPERATION RANGE HEATING MODE
Tlw
At low ambient + high leaving water temperature, the liquid injection prevents the compressor from getting too hot due to high discharge temperature.
New in this model is an electronic expansion valve with optimized injection quantity.
Avoid too high discharge temp by low liquid injection
Liquid injection by EEV (precise control)
Pre
ssur
e (
Bar
)
Enthalpy (KJ/KG)
X X
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
High efficient DHW production
PREVIOUS MODEL NEW MODEL FROM BB SERIES ONWARDS
product features
improved capacity operation range domestic hot water cold ambient
higher leaving water temperature of HP due to optimised liquid injection and improved software control (only for DHW heating)
DHW tank temp. (°C)
Outdoor temp. (°CDB)
35
-20
25 50 80
DHW tank temp. (°C)
Outdoor temp. (°CDB)
35
-20
25 50 80x
-25
CURRENT NEW
-10
X = 50 °Ccombined with Hydrobox up to BA-series X = 55 °C combined with Hydrobox from BB-series onwards
25
Booster heater operation only*
Operation possible but no guarantee of capacity.
If outdoor T < -25°C, the heat pump will stop.
* No booster heater in EKHTS…AC tank
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
HOT GAS PASS
Improved resistance at colder Tambient: hot gas pass
Hot gas pass in bottom plate to keep the temperature of the bottom plate positive. All drain holes are open so drain can get out of the unit
1/5
Limited operation (only shortly before and during defrost cycle hot gas will pass through the hot gas pipe)
product features
improved capacity operation range domestic hot water cold ambient
Pre
ssur
e (
Bar
)
Enthalpy (KJ/KG)
X
Hot gas injection valve
Hot gas pipe
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
Improved resistance at colder Tambient: sub cool pass
2/5
product features
improved capacity operation range domestic hot water cold ambient
Solution against ice build up from bottom
TEST RESULT
(48 hrs, -15℃, 100RH%
+ 12 hrs, -10℃, 100RH%)
Bottom of H/E is free from ice
SUB COOL PASS
Current system New system
sealing
distributor
Additional sealing at the bottom of the heat exchanger to reduce the cooling by airflow
Before the refrigerant pipe is split up by the distributer to the hairpins, the pipe passes through the bottom of the coil.
Current system
New system
capacity: 100Wcontinuous operation if Ta is below 5°C
capacity: 35Woperation only during defrost (3 min.) and max. 3 times per hour
Estimated Yearly consumption = 241.7 kWh/y
Estimated Yearly consumption = 17.1 kWh/y
In extreme conditions, still the electrical bottom plate heater is needed, but smaller size (from 100W reduced to 35 W)
Bottom heater
Consumption of the electrical bottom plate heater:
-90 %
Example for 14kW house at Vienna, Austria
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
(48 hrs, -15℃, 100RH% + 12 hrs, -10℃, 100RH%)
• All drain holes are open
• Inside bottom plate free from ice (only small snow)
Heated bottom plate
TEST RESULT
Improved resistance at colder Tambient: bottom plate
3/5
5 drain holes
More height difference
NEW BOTTOM PLATE
product features
improved capacity operation range domestic hot water cold ambient
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
Improved resistance at colder Tambient: side plate
Ice can build up on metal grid.(48 hrs, -15℃, 100RH%
+ 12 hrs, -10℃, 100RH%)Air flow rate (heat exchange) through side of coil is still OK
4/5
OLD NEW Solution against ice build up starting from grid
TEST RESULT
product features
improved capacity operation range domestic hot water cold ambient
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
Improved resistance at colder Tambient: snow cover and sensor position
5/5
product features
improved capacity operation range domestic hot water cold ambient
SNOW COVER
60
70
10
Advised to install in areas with excessive snowfall
OPTIONAL
AMBIENT SENSOR POSITION
To optimize the accuracy of the ambient sensor, we advise the installer to modify the position of the sensor. An adaptor tool for easy and fast modification can be found in the accessory bag.
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
technical data
1/2
specifications performancecombination table capacity
SPECIFICATIONS TABLE
unit of frequency Outdoor related specs measure compr. 011 014 016 011
OutlookDimensions outdoor unit width mm
depth mmheight mm
Sound power Outdoor unit - Heating mode dBA t.b.c. t.b.c. t.b.c. t.b.c.Outdoor unit - Cooling mode dBA 64,00 66,00 69,00 64,00
Sound pressure Outdoor unit - Heating mode - Nominal dBA 53,00 53,00 53,00 53,00Outdoor unit - Heating mode - maximum dBA 58,00 58,00 58,00 58,00Outdoor unit - Cooling mode dBA 50,00 52,00 54,00 50,00Outdoor unit - night quiet mode dBA 44,00 44,00 45,00 44,00
F-gas compliance factory charge R410A kgpiping length m
011 014 016
t.b.c. t.b.c. t.b.c.64,00 66,00 69,0053,00 53,00 53,0058,00 58,00 58,0050,00 52,00 54,0044,00 44,00 45,00
chargeless: 10 m / max: 50 m3,4
1345320900
ERLQ***CAW1NEW MODEL
3 PHASESPECIFICATIONS TABLE
unit of frequency Outdoor related specs measure compr. 011 014 016 011
OutlookDimensions outdoor unit width mm
depth mmheight mm
Sound power Outdoor unit - Heating mode dBA t.b.c. t.b.c. t.b.c. t.b.c.Outdoor unit - Cooling mode dBA 64,00 66,00 69,00 64,00
Sound pressure Outdoor unit - Heating mode - Nominal dBA 53,00 53,00 53,00 53,00Outdoor unit - Heating mode - maximum dBA 58,00 58,00 58,00 58,00Outdoor unit - Cooling mode dBA 50,00 52,00 54,00 50,00Outdoor unit - night quiet mode dBA 44,00 44,00 45,00 44,00
F-gas compliance factory charge R410A kgpiping length m
chargeless: 10 m / max: 50 m chargeless: 10 m / max: 50 m3,4 3,4
1345 1345320 320900 900
ERLQ***CAV3 ERLQ***CAW1NEW model NEW MODEL
1 PHASE 3 PHASE
Refrigerant charge
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
2/2
technical data
specifications performance
unit of frequency measure compr. 011 014 016 011 014 016
ERLQ***CAV3 ERLQ***CAW1NEW model NEW MODEL
1 PHASE 3 PHASE
11,20 14,00 16,00 11,20 14,00 16,004,66 4,46 4,18 4,66 4,46 4,186,63 7,84 8,77 6,63 7,84 8,772,69 2,52 2,41 2,69 2,52 2,418,50 10,50 11,20 8,50 10,50 11,202,24 2,20 2,16 2,24 2,20 2,1615,05 16,06 16,76 15,05 16,06 16,763,39 3,01 2,76 3,39 3,01 2,7610,30 13,10 15,20 10,30 13,10 15,203,48 3,29 3,29 3,48 3,29 3,296,26 7,99 8,73 6,26 7,99 8,732,05 2,06 2,02 2,05 2,06 2,027,27 9,32 10,19 7,27 9,32 10,191,90 1,87 1,81 1,90 1,87 1,8110,00 12,50 13,10 10,00 12,50 13,102,78 2,51 2,32 2,78 2,51 2,323,35 3,32 3,20 3,35 3,32 3,20
5 520 20
See further See further
10 103 3
standard : 5 m standard : 5 m30 30
> 2,6 > 2,6
50 50
Performance on set-baseHeating capacity kW Nominal (*3)minimum COP (heating) Nominal (*3)Heating capacity kW Nominal (*3)minimum COP (heating) Nominal (*3)Heating capacity kW Maximum (*3)minimum COP (heating) Maximum (*3)Cooling capacity (only in comb. With EKHBX) kW Nominal (*3)minimum EER (Cooling) Nominal (*3)Heating capacity kW Nominal (*3)minimum COP (heating) Nominal (*3)Heating capacity kW Nominal (*3)minimum COP (heating) Nominal (*3)Heating capacity kW Maximum (*3)minimum COP (heating) Maximum (*3)Cooling capacity (only in comb. With EKHBX) kW Nominal (*3)minimum EER (Cooling) Nominal (*3)
Ta = 2 °CDB / 1°CWB ; EWC=30°C / LWC = 35 °C minimum COP (heating) Nominal (*3)Ta = 2 °CDB / 1°CWB ; EWC=40°C / LWC = 45 °C minimum COP (heating) Nominal (*3)
PISystem related specs
piping restrictionsmax piping length between outdoor unit and hydro-box m
max height difference between outdoor unit and hydro-box mmin piping length between outdoor unit and hydro-box mmax distance between 3W-valve and hydrokit mmax distance between hydrokit and sanitary tank m
operating rangemin water volume content of the system lmax height difference between heighest and lowest point in the installation at water-side m
Other
FCU
Rated condition: Ta = 7 °CDB / 6°CWB ; EWC=40°C / LWC = 45 °C
low abmient: Ta = -7 °CDB / -8°CWB ; EWC= (*1) / LWC = 45 °C
low abmient: Ta = -7 °CDB / -8°CWB ; EWC= (*1) / LWC = 45 °C
Rated condition: Ta = 35 °CDB ; EWC=12°C / LWC = 7 °C
Floor
Rated condition: Ta = 7 °CDB / 6°CWB ; EWC=30°C / LWC = 35 °C
low abmient: Ta = -7 °CDB / -8°CWB ; EWC= (*1) / LWC = 35 °C
low abmient: Ta = -7 °CDB / -8°CWB ; EWC= (*1) / LWC = 35 °C
Rated condition: Ta = 35 °CDB ; EWC=23°C / LWC = 18 °C
(*1) Temperature based on output indentical to the heating mode test at + 7 °C outdoors.(*2) maximum possible COP should be published from competition point of view; indicated value (2,5) = minimum value to pass Vivrelec / NF-pac condition for FCU(*3) According to Nominal conditions, with refrigerant piping length : 5 m - Integrated values
Performance data according to GWWA008-X B
(*4) : For the countermeasure models (V38 / W18 / ERLQ), the performance will be influenced by the heater tape.However, the inpact of the Power input on EER / COP, should not influence the compliance to DACH certification.
combination table capacity
(*1) Temperature based on output indentical to the heating mode test at + 7 °C outdoors.(*2) maximum possible COP should be published from competition point of view; indicated value (2,5) = minimum value to pass Vivrelec / NF-pac condition for FCU(*3) According to Nominal conditions, with refrigerant piping length : 5 m - Integrated values
Performance data according to GWWA008-X B
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
Combination table
technical data
specifications combination table performance
outdoor unit indoor units
heat emissionheat generation
OPTIONAL DHW tank
UFH
HP convectorNEW
OR OR
These models will replace all previous ERLQ…BA models
ERLQ011CAV3ERLQ014CAV3ERLQ016CAV3ERLQ011CAW1ERLQ014CAW1ERLQ016CAW1
1P
3P
* 6 kW BUH can be installed as 3 kW** 6 kW BUH can be installed as 2 kW***9 kW BUH can be installed as 3 kW
Mass production from Sept 2010 onwards
BB software units will replace BA software units from okt 2010 onwards
NOT in combination with wall mounted HB BA software
capacity
inst
alla
tion
wal
l
200 300 150 200 300 200 260
mo
del
nam
e
EK
HW
ET
150A
-
EK
HW
E15
0A-
EK
HW
E20
0A-
EK
HW
E30
0A-
EK
HW
S15
0B-
EK
HW
S20
0B-
EK
HW
S30
0B-
EK
HT
S20
0AC
EK
HT
S26
0AC
boos
ter
heat
er
pow
er s
uppl
y
O O O O O O O -3V3 3kW 1P, 230VO O O O -3Z2 3kW 2P, 400V
O O no
water volume
materialenamel stainless steel
150flo
or s
tand
ing
floor
sta
ndin
g
inte
grat
ed d
esig
n
hea
tin
g o
nly
reve
rsib
le
hea
tin
g o
nly
reve
rsib
le
hea
tin
g o
nly
reve
rsib
le
mo
del
nam
e
EK
HB
H01
6BA
-
EK
HB
X01
6BA
-
EK
HB
H01
6BB
-
EK
HB
X01
6BB
-
EK
HV
H01
6BB
-
EK
HV
X01
6BB
-
BU
H c
ap (
kW)
Pow
er s
uppl
y
O O O O -3V3 3 1P, 230VO O O* O* O* O* -6V3 1P, 230VO O O** O** O** O** -6WN 3P, 400VO O O** O** -6T1 3P, 230VO O O*** O*** O*** O*** -9WN 3P, 400VO O O*** -9T1 3P, 230V
6
9
wall wall floor
BA BB BB
installation
software
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
Outdoor T (°C)
0-7 7
ERLQ011CA – 35°CERLQ014CA – 35°CERLQ016CA – 35°C
COP
Performance at nominal compressor frequency
technical data
specifications combination table performance capacity
ERLQ011CA – 45°CERLQ014CA – 45°CERLQ016CA – 45°C
2
3.5
4.5
4
3
2.5
DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW
concept explanation technical dataproduct features
Tentative data – Daikin Europe NV design dpt has the right to change the data R4
technical data
specifications combination table performance capacity
-20° 0° 16°
16
14
Outdoor T (°C)
Heating capacity
(kW)
12
ERLQ016CA
ERLQ014CA
ERLQ011CA
7°-7°
SYSTEM HEATING INTEGRATED CAPACITY
Improved capacity
10
8
6
Maximal integrated heating capacity EWC=30°C / LWC=35°C