DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanation technical data product features Tentative data – Daikin Europe NV design dpt has the right to change the data R4 Daikin launches a heatpump for colder climates START Daikin Europe NV is applying to obtain the Ecolabel for this unit. DAIKIN ALTHERMA 11-16kW ERLQ…CA: the heatpump for heating and domestic hot water preparation in severe winter conditions High capacity at low ambient Increased operation range High efficient defrost High efficient domestic hot water production

Upload: gordon-paul

Post on 21-Dec-2015

239 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

Daikin launches a heatpump for colder climates

START

Daikin Europe NV is applying to obtain the Ecolabel for this unit.

DAIKIN ALTHERMA 11-16kW ERLQ…CA: the heatpump for heating and

domestic hot water preparation in severe winter conditions

High capacity at low ambient

Increased operation range

High efficient defrost

High efficient domestic hot water production

Page 2: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

outdoor unit indoor units

heat emissionheat generation

OPTIONAL DHW tank

* Nominal heating capacity at Ta=7°C / EWC=30°C / LWC=35°C

** Nominal cooling capacity at Ta=35°C / EWC=23°C / LWC=18°C

( cooling function is only available in combination with reversible type hydrobox

These models will replace all previous ERLQ---BA models

11.2kW* 16kW*

15.0kW** 16.8kW**

14kW*

16.1kW**

ERLQ011CAV3ERLQ014CAV3ERLQ016CAV3

1P230V

3P400V

HeatingCooling

Heatingonly

16kW*

Wall hang Floor standing‘integrated design’

EKHB EKHV

Enamel / Stainless steelStainless steel

‘integrated design’

150 – 200 – 300 L 200 – 260 L

EKHW EKHTERLQ011CAW1ERLQ014CAW1ERLQ016CAW1

concept explanation

Layout of the product

layout

UFH

HP convector

NEW

OROR

▪ extended operation range on 1-phase units▪ improved efficiency of DHW-production

2 - Avoid blockage of bottom plate

▪ increase holes in bottom frame▪ improve bottom plate heater (smaller capacity, intelligent control)

3 - Avoid ice accumulation

▪ remove grid from side plate▪ software update

▪ development of snowcover option

▪ hot gas defrosting

▪ adding sub cool pass

▪ increased capacity at low ambient conditions

1 - Improve performance

Page 3: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

Outdoor T (°C)

product features

improved capacity operation range domestic hot water cold ambient

Improved capacity

Higher compressor frequency improved capacity compared to previous model

new model ERLQ016CAW1 compared to previous ERLQ016BAW1 installed in a 14kW house at Vienna, Austria.

Less need of backup heater=

higher system COP

Integrated CO

P

Less BUH support needed!

Example

HP and system capacity are higher at low ambient temperatures.

ERLQ016CERLQ016B

ERLQ016CERLQ016B

1/2

+2 kW @ -15°C

Increased heating capacity

NO BUH support needed!

Therm

al o

utp

ut

(kW

h/C

°)

Outdoor T (°C)

Page 4: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

product features

improved capacity operation range domestic hot water cold ambient

Improved capacity

Higher compressor frequency improved capacity compared to previous model

2/2

Changes in piping diagram

HIGH PRESSURE SIDE

LOW PRESSURE SIDE

HEATING CYCLE

Daikin scroll compressor

Animation of Daikin scroll compressor operation

Page 5: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

Design improvements to increase operation range: EEV injection

product features

improved capacity operation range domestic hot water cold ambient

Tlw

Ta

25 40 55

-25

0

35

-20

Ta

25 40 55

-25

0

35

-20

Previous single phase ERLQ unit New ERLQ unit

( single and 3phase)

Max. leaving water temp. is independent of the ambient temp.Compressor operation till -25°C

EXTENDED OPERATION RANGE HEATING MODE

Tlw

At low ambient + high leaving water temperature, the liquid injection prevents the compressor from getting too hot due to high discharge temperature.

New in this model is an electronic expansion valve with optimized injection quantity.

Avoid too high discharge temp by low liquid injection

Liquid injection by EEV (precise control)

Pre

ssur

e (

Bar

)

Enthalpy (KJ/KG)

X X

Page 6: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

High efficient DHW production

PREVIOUS MODEL NEW MODEL FROM BB SERIES ONWARDS

product features

improved capacity operation range domestic hot water cold ambient

higher leaving water temperature of HP due to optimised liquid injection and improved software control (only for DHW heating)

DHW tank temp. (°C)

Outdoor temp. (°CDB)

35

-20

25 50 80

DHW tank temp. (°C)

Outdoor temp. (°CDB)

35

-20

25 50 80x

-25

CURRENT NEW

-10

X = 50 °Ccombined with Hydrobox up to BA-series X = 55 °C combined with Hydrobox from BB-series onwards

25

Booster heater operation only*

Operation possible but no guarantee of capacity.

If outdoor T < -25°C, the heat pump will stop.

* No booster heater in EKHTS…AC tank

Page 7: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

HOT GAS PASS

Improved resistance at colder Tambient: hot gas pass

Hot gas pass in bottom plate to keep the temperature of the bottom plate positive. All drain holes are open so drain can get out of the unit

1/5

Limited operation (only shortly before and during defrost cycle hot gas will pass through the hot gas pipe)

product features

improved capacity operation range domestic hot water cold ambient

Pre

ssur

e (

Bar

)

Enthalpy (KJ/KG)

X

Hot gas injection valve

Hot gas pipe

Page 8: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

Improved resistance at colder Tambient: sub cool pass

2/5

product features

improved capacity operation range domestic hot water cold ambient

Solution against ice build up from bottom

TEST RESULT

(48 hrs, -15℃, 100RH%

+ 12 hrs, -10℃, 100RH%)

Bottom of H/E is free from ice

SUB COOL PASS

Current system New system

sealing

distributor

Additional sealing at the bottom of the heat exchanger to reduce the cooling by airflow

Before the refrigerant pipe is split up by the distributer to the hairpins, the pipe passes through the bottom of the coil.

Current system

New system

capacity: 100Wcontinuous operation if Ta is below 5°C

capacity: 35Woperation only during defrost (3 min.) and max. 3 times per hour

Estimated Yearly consumption = 241.7 kWh/y

Estimated Yearly consumption = 17.1 kWh/y

In extreme conditions, still the electrical bottom plate heater is needed, but smaller size (from 100W reduced to 35 W)

Bottom heater

Consumption of the electrical bottom plate heater:

-90 %

Example for 14kW house at Vienna, Austria

Page 9: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

(48 hrs, -15℃, 100RH% + 12 hrs, -10℃, 100RH%)

• All drain holes are open

• Inside bottom plate free from ice (only small snow)

Heated bottom plate

TEST RESULT

Improved resistance at colder Tambient: bottom plate

3/5

5 drain holes

More height difference

NEW BOTTOM PLATE

product features

improved capacity operation range domestic hot water cold ambient

Page 10: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

Improved resistance at colder Tambient: side plate

Ice can build up on metal grid.(48 hrs, -15℃, 100RH%

+ 12 hrs, -10℃, 100RH%)Air flow rate (heat exchange) through side of coil is still OK

4/5

OLD NEW Solution against ice build up starting from grid

TEST RESULT

product features

improved capacity operation range domestic hot water cold ambient

Page 11: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

Improved resistance at colder Tambient: snow cover and sensor position

5/5

product features

improved capacity operation range domestic hot water cold ambient

SNOW COVER

60

70

10

Advised to install in areas with excessive snowfall

OPTIONAL

AMBIENT SENSOR POSITION

To optimize the accuracy of the ambient sensor, we advise the installer to modify the position of the sensor. An adaptor tool for easy and fast modification can be found in the accessory bag.

Page 12: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

technical data

1/2

specifications performancecombination table capacity

SPECIFICATIONS TABLE

unit of frequency Outdoor related specs measure compr. 011 014 016 011

OutlookDimensions outdoor unit width mm

depth mmheight mm

Sound power Outdoor unit - Heating mode dBA t.b.c. t.b.c. t.b.c. t.b.c.Outdoor unit - Cooling mode dBA 64,00 66,00 69,00 64,00

Sound pressure Outdoor unit - Heating mode - Nominal dBA 53,00 53,00 53,00 53,00Outdoor unit - Heating mode - maximum dBA 58,00 58,00 58,00 58,00Outdoor unit - Cooling mode dBA 50,00 52,00 54,00 50,00Outdoor unit - night quiet mode dBA 44,00 44,00 45,00 44,00

F-gas compliance factory charge R410A kgpiping length m

011 014 016

t.b.c. t.b.c. t.b.c.64,00 66,00 69,0053,00 53,00 53,0058,00 58,00 58,0050,00 52,00 54,0044,00 44,00 45,00

chargeless: 10 m / max: 50 m3,4

1345320900

ERLQ***CAW1NEW MODEL

3 PHASESPECIFICATIONS TABLE

unit of frequency Outdoor related specs measure compr. 011 014 016 011

OutlookDimensions outdoor unit width mm

depth mmheight mm

Sound power Outdoor unit - Heating mode dBA t.b.c. t.b.c. t.b.c. t.b.c.Outdoor unit - Cooling mode dBA 64,00 66,00 69,00 64,00

Sound pressure Outdoor unit - Heating mode - Nominal dBA 53,00 53,00 53,00 53,00Outdoor unit - Heating mode - maximum dBA 58,00 58,00 58,00 58,00Outdoor unit - Cooling mode dBA 50,00 52,00 54,00 50,00Outdoor unit - night quiet mode dBA 44,00 44,00 45,00 44,00

F-gas compliance factory charge R410A kgpiping length m

chargeless: 10 m / max: 50 m chargeless: 10 m / max: 50 m3,4 3,4

1345 1345320 320900 900

ERLQ***CAV3 ERLQ***CAW1NEW model NEW MODEL

1 PHASE 3 PHASE

Refrigerant charge

Page 13: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

2/2

technical data

specifications performance

unit of frequency measure compr. 011 014 016 011 014 016

ERLQ***CAV3 ERLQ***CAW1NEW model NEW MODEL

1 PHASE 3 PHASE

11,20 14,00 16,00 11,20 14,00 16,004,66 4,46 4,18 4,66 4,46 4,186,63 7,84 8,77 6,63 7,84 8,772,69 2,52 2,41 2,69 2,52 2,418,50 10,50 11,20 8,50 10,50 11,202,24 2,20 2,16 2,24 2,20 2,1615,05 16,06 16,76 15,05 16,06 16,763,39 3,01 2,76 3,39 3,01 2,7610,30 13,10 15,20 10,30 13,10 15,203,48 3,29 3,29 3,48 3,29 3,296,26 7,99 8,73 6,26 7,99 8,732,05 2,06 2,02 2,05 2,06 2,027,27 9,32 10,19 7,27 9,32 10,191,90 1,87 1,81 1,90 1,87 1,8110,00 12,50 13,10 10,00 12,50 13,102,78 2,51 2,32 2,78 2,51 2,323,35 3,32 3,20 3,35 3,32 3,20

5 520 20

See further See further

10 103 3

standard : 5 m standard : 5 m30 30

> 2,6 > 2,6

50 50

Performance on set-baseHeating capacity kW Nominal (*3)minimum COP (heating) Nominal (*3)Heating capacity kW Nominal (*3)minimum COP (heating) Nominal (*3)Heating capacity kW Maximum (*3)minimum COP (heating) Maximum (*3)Cooling capacity (only in comb. With EKHBX) kW Nominal (*3)minimum EER (Cooling) Nominal (*3)Heating capacity kW Nominal (*3)minimum COP (heating) Nominal (*3)Heating capacity kW Nominal (*3)minimum COP (heating) Nominal (*3)Heating capacity kW Maximum (*3)minimum COP (heating) Maximum (*3)Cooling capacity (only in comb. With EKHBX) kW Nominal (*3)minimum EER (Cooling) Nominal (*3)

Ta = 2 °CDB / 1°CWB ; EWC=30°C / LWC = 35 °C minimum COP (heating) Nominal (*3)Ta = 2 °CDB / 1°CWB ; EWC=40°C / LWC = 45 °C minimum COP (heating) Nominal (*3)

PISystem related specs

piping restrictionsmax piping length between outdoor unit and hydro-box m

max height difference between outdoor unit and hydro-box mmin piping length between outdoor unit and hydro-box mmax distance between 3W-valve and hydrokit mmax distance between hydrokit and sanitary tank m

operating rangemin water volume content of the system lmax height difference between heighest and lowest point in the installation at water-side m

Other

FCU

Rated condition: Ta = 7 °CDB / 6°CWB ; EWC=40°C / LWC = 45 °C

low abmient: Ta = -7 °CDB / -8°CWB ; EWC= (*1) / LWC = 45 °C

low abmient: Ta = -7 °CDB / -8°CWB ; EWC= (*1) / LWC = 45 °C

Rated condition: Ta = 35 °CDB ; EWC=12°C / LWC = 7 °C

Floor

Rated condition: Ta = 7 °CDB / 6°CWB ; EWC=30°C / LWC = 35 °C

low abmient: Ta = -7 °CDB / -8°CWB ; EWC= (*1) / LWC = 35 °C

low abmient: Ta = -7 °CDB / -8°CWB ; EWC= (*1) / LWC = 35 °C

Rated condition: Ta = 35 °CDB ; EWC=23°C / LWC = 18 °C

(*1) Temperature based on output indentical to the heating mode test at + 7 °C outdoors.(*2) maximum possible COP should be published from competition point of view; indicated value (2,5) = minimum value to pass Vivrelec / NF-pac condition for FCU(*3) According to Nominal conditions, with refrigerant piping length : 5 m - Integrated values

Performance data according to GWWA008-X B

(*4) : For the countermeasure models (V38 / W18 / ERLQ), the performance will be influenced by the heater tape.However, the inpact of the Power input on EER / COP, should not influence the compliance to DACH certification.

combination table capacity

(*1) Temperature based on output indentical to the heating mode test at + 7 °C outdoors.(*2) maximum possible COP should be published from competition point of view; indicated value (2,5) = minimum value to pass Vivrelec / NF-pac condition for FCU(*3) According to Nominal conditions, with refrigerant piping length : 5 m - Integrated values

Performance data according to GWWA008-X B

Page 14: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

Combination table

technical data

specifications combination table performance

outdoor unit indoor units

heat emissionheat generation

OPTIONAL DHW tank

UFH

HP convectorNEW

OR OR

These models will replace all previous ERLQ…BA models

ERLQ011CAV3ERLQ014CAV3ERLQ016CAV3ERLQ011CAW1ERLQ014CAW1ERLQ016CAW1

1P

3P

* 6 kW BUH can be installed as 3 kW** 6 kW BUH can be installed as 2 kW***9 kW BUH can be installed as 3 kW

Mass production from Sept 2010 onwards

BB software units will replace BA software units from okt 2010 onwards

NOT in combination with wall mounted HB BA software

capacity

inst

alla

tion

wal

l

200 300 150 200 300 200 260

mo

del

nam

e

EK

HW

ET

150A

-

EK

HW

E15

0A-

EK

HW

E20

0A-

EK

HW

E30

0A-

EK

HW

S15

0B-

EK

HW

S20

0B-

EK

HW

S30

0B-

EK

HT

S20

0AC

EK

HT

S26

0AC

boos

ter

heat

er

pow

er s

uppl

y

O O O O O O O -3V3 3kW 1P, 230VO O O O -3Z2 3kW 2P, 400V

O O no

water volume

materialenamel stainless steel

150flo

or s

tand

ing

floor

sta

ndin

g

inte

grat

ed d

esig

n

hea

tin

g o

nly

reve

rsib

le

hea

tin

g o

nly

reve

rsib

le

hea

tin

g o

nly

reve

rsib

le

mo

del

nam

e

EK

HB

H01

6BA

-

EK

HB

X01

6BA

-

EK

HB

H01

6BB

-

EK

HB

X01

6BB

-

EK

HV

H01

6BB

-

EK

HV

X01

6BB

-

BU

H c

ap (

kW)

Pow

er s

uppl

y

O O O O -3V3 3 1P, 230VO O O* O* O* O* -6V3 1P, 230VO O O** O** O** O** -6WN 3P, 400VO O O** O** -6T1 3P, 230VO O O*** O*** O*** O*** -9WN 3P, 400VO O O*** -9T1 3P, 230V

6

9

wall wall floor

BA BB BB

installation

software

Page 15: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

Outdoor T (°C)

0-7 7

ERLQ011CA – 35°CERLQ014CA – 35°CERLQ016CA – 35°C

COP

Performance at nominal compressor frequency

technical data

specifications combination table performance capacity

ERLQ011CA – 45°CERLQ014CA – 45°CERLQ016CA – 45°C

2

3.5

4.5

4

3

2.5

Page 16: DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW concept explanationtechnical dataproduct features Tentative data – Daikin Europe NV design dpt has

DAIKIN ALTHERMA ERLQ…CA – capacity range 011 – 016 kW

concept explanation technical dataproduct features

Tentative data – Daikin Europe NV design dpt has the right to change the data R4

technical data

specifications combination table performance capacity

-20° 0° 16°

16

14

Outdoor T (°C)

Heating capacity

(kW)

12

ERLQ016CA

ERLQ014CA

ERLQ011CA

7°-7°

SYSTEM HEATING INTEGRATED CAPACITY

Improved capacity

10

8

6

Maximal integrated heating capacity EWC=30°C / LWC=35°C