daikin air conditioners for small rooms in multi application...daikin products are distributed by:...

6
Daikin air conditioners for small rooms in multi application CONCEALED CEILING UNIT FDBQ-B www.daikineurope.com PRELIMINARY

Upload: others

Post on 25-Jun-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Daikin air conditioners for small rooms in multi application...Daikin products are distributed by: Zandvoordestraat 300 B-8400 Oostende, Belgium Daikin’s unique position as a manufacturer

Daik in a i r condi t ioners

for smal l rooms in mul t i app l i cat ion

CONCEALED CE I L ING UN IT

FDBQ-B

ww

w.d

aik

ine

uro

pe

.co

m

PRELIMINARY

hayez_EPLE05-22B_P 19/01/06 10:34 Page 3

mov93585_EPLe05-22B_P

Cyan Magenta Yellow Black

Page 2: Daikin air conditioners for small rooms in multi application...Daikin products are distributed by: Zandvoordestraat 300 B-8400 Oostende, Belgium Daikin’s unique position as a manufacturer

• You have the choice of 2 fan speeds to select: high or low. A high fan speed providesmaximum reach while a low fan speed minimizes draughts.

• The indoor unit is very quiet in operation. The sound levels are as low as 29dB (A),comparable to rustling leaves.

• The indoor unit contains an air filter which removes microscopic particles and dust.

COMFORT

• Since the indoor unit is low in height it fits flush into narrow ceiling voids.

• The outdoor unit can be installed on a roof or terrace or placed against an outside wall.

• Special anti-corrosion treatmentof the outdoor unit’s heat exchangerfin, gives greater resistance againstacid rain and salt corrosion.Additional resistance is provided bya rust proof steel sheet on theunderside of the unit.

FLEXIBLE INSTALLATION AND EASY TO MAINTAIN

Concealed ceiling units are ideal for use in small rooms such as hotel bedrooms.They are built into the false ceiling, leaving only the suction and discharge grillesvisible. The grilles can be placed wherever you want and blend with any interiordécor. Not only are concealed ceiling units visually unobtrusive, they are alsoamong the quietest types of air conditioning.

1

Can be 0.5 m long

An anti-corrosion heatexchanger cutaway view

Aluminium

Hydrophilic film

Corrosion-resistantAcrylic resin

• The air duct between the indoor unit and the discharge grille can be up to 0.5m

• Daikin remote controls give you easy control at your fingertips.

• The wired remote control provides you with a schedule timer, enabling to program theair conditioning daily or weekly.

Heat exchanger

• For hotel applications the indoor unit can be switched off at reception when a guestchecks out and restarted when one checks in. It can also be operated by remote controlto switch off if a window is opened and restart on its closure and similarly, to switch offwhen a guest leaves the room and restart when one enters.

1

hayez_EPLE05-22B_P 19/01/06 10:34 Page 4

mov93585_EPLe05-22B_P

Cyan Magenta Yellow Black

Page 3: Daikin air conditioners for small rooms in multi application...Daikin products are distributed by: Zandvoordestraat 300 B-8400 Oostende, Belgium Daikin’s unique position as a manufacturer

PRELIMINARY INFO

Dimensions HxWxD mmWeight kgAir flow rate cooling H/L m3/min

heating H/L m3/minFan speedSound pressure level cooling H/L dB(A)

heating H/L dB(A)Sound power level cooling H/L dB(A)

heating H/L dB(A)Piping connections liquid mm

gas mmdrain ID mm

OD mmHeat insulation

Capacity and power input

Specifications indoor units

Indoor unit : FDBQ-B

230x652x50217

6.5/5.26.95/5.2

2 steps (direct drive)35/2835/2955/4955/49ø6.35ø9.52ø21.6ø27.2

Both liquid and gas pipes

COOLING ONLY/HEAT PUMP FDBQ25B

FDBQ25B

PRELIMINARYINFO

PRELIMINARYINFO

Notes: - For more detailed information about specifications, capacities, power input, energy labelling and annual energy consumption, please refer to our Multi Model catalogue/Super Multi Plus catalogue or check

with your local dealer.* At least 2 indoor units should be connected to a Multi outdoor unit.

MULTI - COOLING ONLY

4MKS58E4MKS75E5MKS90EMULTI - HEAT PUMP

2MXS52E*3MXS52E*4MXS68E*4MXS80E*5MXS90E*SUPER MULTI PLUS - HEAT PUMP

RMXS112E*RMXS140E*RMXS160E*

Max. n° Max. cooling Max. PI coolingof indoor units capacities (kW) (kW)

4 6.6 2.474 9.27 3.714 10 2.58

Max. n° Max. cooling Max. PI cooling Max. heating Max. PI heatingof indoor units capacities (kW) (kW) capacities (kW) (kW)

2 6.5 2.69 7.34 2.423 6.5 2.69 7.34 2.424 8.68 3.69 10.64 3.414 8.5 2.16 10 2.595 10.5 2.47 11.5 2.65

Max. n° Max. cooling Max. PI cooling Max. heating Max. PI heatingof indoor units capacities (kW) (kW) capacities (kW) (kW)

7 11.2 3.57 12.5 4.018 14 5.23 16 5.319 15.5 5.55 17.5 5.56

hayez_EPLE05-22B_P 19/01/06 10:34 Page 5

mov93585_EPLe05-22B_P

Cyan Magenta Yellow Black

Page 4: Daikin air conditioners for small rooms in multi application...Daikin products are distributed by: Zandvoordestraat 300 B-8400 Oostende, Belgium Daikin’s unique position as a manufacturer

PREL

IMIN

ARY

INFO

PREL

IMIN

ARY

INFO

2MXS/3MXS/4MKS/5MKS/4MXS/5MXS-E RMXS-E

KPW945A4 KPW945A4- KKPJF180- KHRQ22M20TA- BPMKS967A2B- BPMKS967A3B

PRELIMINARY

INFOPRELIMINARY

INFO

735x936x300 770x900x32055 58 68

ivory white46/43 48/- 48/45

59 61 61hermetically sealed swing

R-410Acharge less

45 60 752515

7.5 15-10~46

3MXS52E 4MXS68E 4MXS80E 5MXS90E RMXS112E RMXS140E RMXS160E

735x936x300 770x900x320 770x900x320 1,345x900x32055 59 73 68 127

Ivory white Ivory white46/43 48/- 48/46 52/49 51 52 5447/44 49/- 49/46 52/49 53 54 56

59 61 61 65 67 68 7060 62 62 65 - - -

hermetically sealed scroll hermetically sealed scrollR-410A R-410A

0.02 (30m or more) 0.02(30m or more) charge less -45 60 75 115 (total system) 135 (total system) 145 (total system)

25 55 (total outdoor unit - BP)15 307.5 30 (outdoor - BP)- 15- 15

-10~46 -5~46-15~15 -15~15.5

COOLING ONLY 4MKS58E 4MKS75E 5MKS90E

Specifications outdoor units

Accessories: control systems

Accessories

INDOOR UNITS FDBQ25B

Wired remote control BRC1D52Adapter for wiring (hour meter)* EKRP1B2Remote ON/OFF, forced OFF EKRORO

* Possibility to connect an hour meter (field supply). This part should not be installed inside the equipment.

- Information is not available

OUTDOOR UNITS

Air direction adjustment grilleDrain plugRefnet jointBranch provider (2 rooms)Branch provider (3 rooms)

Dimensions HxWxD mmWeight kgCasing colourSound pressure level H/L dB(A)Sound power level H dB(A)CompressorRefrigerant typeAmount of additinal charge kg/mMaximum piping length for total of each room m

for one room mMaximum level difference between ind. and outd. unit m

between indoor units mOperation range cooling from ~ to °CDBHEAT PUMP

Dimensions HxWxD mmWeight kgCasing colourSound pressure level cooling H/L dB(A)

heating H/L dB(A)Sound power level cooling H dB(A)

heating H dB(A)CompressorRefrigerant typeAmount of additinal charge kg/mMaximum piping length for total of each room m

for one room mMaximum level difference between ind. and outd. unit m

between indoor units mBP - BP mindoor - indoor m

Operation range cooling from ~ to °CDBheating from ~ to °CWB

Notes:1) V1 = 1~,230V,50Hz; VM = 1~, 220-240V/220-230V, 50Hz/60Hz2) Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB • outdoor temperature 35°CDB • refrigerant piping length 7.5m • level difference 0m.3) Nominal heating capacities are based on: indoor temperature 20°CDB • outdoor temperature 7°CDB/6°CWB • refrigerant piping length 7.5m • level difference 0m.4) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.5) Units should be selected on nominal capacity. Max. capacity is limited to peak periods.6) The sound pressure level is measured at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment.7) The sound power level is an absolute value indicating the "power" which a sound source generates.

hayez_EPLE05-22B_P 19/01/06 10:34 Page 6

mov93585_EPLe05-22B_P

Cyan Magenta Yellow Black

Page 5: Daikin air conditioners for small rooms in multi application...Daikin products are distributed by: Zandvoordestraat 300 B-8400 Oostende, Belgium Daikin’s unique position as a manufacturer

Wired remotecontrol (Optional)

ENERGY EFFICIENT

• This model can be used both in cooling only or heating.

• It is possible to use the indoor unit in multi application. This system allows you to haveair conditioning in several rooms. In fact, up to 9 different indoor units can be connectedto 1 outdoor unit operating individually.

APPLICATION OPTIONS

When you go out pushthe “Home leaveoperation” button, andthe air conditioner willadjust capacity to reachthe preset temperaturefor “Home leaveoperation”.

When you return, youwill be welcomed bya comfortableair-conditioned room.

Push the “Home leaveoperation” button again,and the air conditionerwill adjust capacity tothe set temperature fornormal operation.

While out of the home

Inverter air conditioning

Non inverterair conditioning

Set point

Large temperaturedifference

Repeats hot and cold cycles

Keeps temperature stable

Startup time reducedby about 1/3

Slow start-up

Improved comfort:The rapid start up time provided by the inverter increases comfort by reducing the leadtime in obtaining the required indoor temperature. As soon as the required temperatureis reached, the inverter unit continuously scans the room for small changes and adjuststhe room temperature in seconds, thereby increasing comfort once again.

• The ‘home leave’ operation button prevents large temperature differences bycontinuously operating at a minimum (heating mode) or maximum (cooling mode) presetlevel while you’re out or sleeping. It also allows the indoor temperature to return quicklyto your favourite comfort level.

Smallertemperaturedifference

PUSH AGAIN

• Inverter technologyImproved energy efficiency:The use of integrated inverter control ensures maximum energy efficiency by supplyingonly the required heating or cooling load where a standard non inverter unit would supplymaximum load in an on/off regime.

ONE PUSH

hayez_EPLE05-22B_P 19/01/06 10:34 Page 1

mov93585_EPLe05-22B_P

Cyan Magenta Yellow Black

Page 6: Daikin air conditioners for small rooms in multi application...Daikin products are distributed by: Zandvoordestraat 300 B-8400 Oostende, Belgium Daikin’s unique position as a manufacturer

EPLE

05-2

2B_P

/ 1,1

00 /

01/0

6 / L

a M

ovid

aPr

inte

d o

n n

on

-ch

lori

nat

ed p

aper

/ P

rin

ted

in

Bel

giu

m

Daikin products are distributed by:

Zandvoordestraat 300

B-8400 Oostende, Belgium

www.daikineurope.com

Daikin’s unique position as a manufacturerof air conditioning equipment, compressorsand refrigerants has led to its closeinvolvement in environmental issues. Forseveral years Daikin has had the intention tobecome a leader in the provision ofenvironmental friendly products. Thischallenge demands the eco design anddevelopment of a wide range of productsand an energy management system; whichinvolves energy conservation and reductionof waste.

“The present leaflet is drawn up by way of information only anddoes not constitute an offer binding upon Daikin Europe N.V..Daikin Europe N.V. has compiled the content of this leaflet tothe best of its knowledge. No express or implied warranty isgiven for the completeness, accuracy, reliability or fitness forparticular purpose of its content and the products and servicespresented therein. Specifications are subject to change withoutprior notice. Daikin Europe N.V. explicitly rejects any liability forany direct or indirect damage, in the broadest sense, arisingfrom or related to the use and/or interpretation of this leaflet.All content is copyrighted by Daikin Europe N.V.”

Daikin Europe N.V. is approved by LRQA for itsQuality Management System in accordance withthe ISO9001 standard.ISO9001 pertains to quality assurance regardingdesign, development, manufacturing as well as toservices related to the product.

ISO14001 assures an effective environmentalmanagement system in order to help protect humanhealth and the environment from the potentialimpact of our activities, products and services andto assist in maintaining and improving the qualityof the environment.

Daikin units comply with the European regulationsthat guarantee the safety of the product.

Daikin Europe N.V. participates in the EuroventCertification Programme for Air Conditioners (AC),Liquid Chilling Packages (LCP) and Fan Coil Units(FC); the certified data of certified models are listedin the Eurovent Directory. Multi units are Euroventcertified for combinations up to 2 indoor units.

hayez_EPLE05-22B_P 19/01/06 10:35 Page 2

mov93585_EPLe05-22B_P

Cyan Magenta Yellow Black