d-lab.2, d-lab.2plus, netlab - saal-group. · pdf fileagfaphoto is used under license of...
TRANSCRIPT
Service Manual
Digital Minilabs
Preinstallation Order number DD+18060A192D0 Edition 2005-05-01 Version English, 04100_01
d-lab.2: 8060/260, 8060/803, 8060/804, 8060/270, 8060/272, 8060/157 + 8060/255
d-lab.2plus: 8060/261 8060/813, 8060/814 8060/271, 8060/273 8060/158 + 8060/255
netlab.2plus: 8060/505
Modification History
Version Edition Modifications
04100_00 2004-10-01 Combination of the Service Manuals – Preinstallation for the machines d-lab.2, d-lab.2plus, and netlab.2plus; Additions and update for the order aid
04100_01 2005-05-01 Migration AgfaPhoto
© 2005 AgfaPhoto GmbH. Alle Rechte vorbehalten.
No part of these instructions may be reproduced, copied, or transmitted in any form or by any means without prior written permission by AgfaPhoto GmbH.
AgfaPhoto is used under license of Agfa-Gevaert AG
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Contents
AgfaPhoto 2005-05-01 / PN 04100_01 i
Contents
1 General ................................................................................................................................1 1.1 Validity of this documentation ....................................................................................................................................1 1.2 Preparation by the Customer........................................................................................................................................1 1.3 Measures by the AgfaPhoto Technician ...................................................................................................................1
2 Machine Dimensions and Weight ...........................................................................................2 2.1 Machine Dimensions and Weight, Packed..............................................................................................................2 2.2 Machine Dimensions, Unpacked.................................................................................................................................3 2.3 Weight, Unpacked.............................................................................................................................................................6
3 Transport..............................................................................................................................7 4 Operation Site ......................................................................................................................7
4.1 Separation of the Food Section ...................................................................................................................................7 4.2 Room Requirements.........................................................................................................................................................7 4.3 Required Space for Operation, Maintenance, and Service ................................................................................8 4.4 Room Lighting ....................................................................................................................................................................9 4.5 Water Connection, Cleaning Sink...............................................................................................................................9 4.6 Chemicals.......................................................................................................................................................................... 10
4.6.1 Legal Regulations....................................................................................................................................... 10 4.6.2 Safety Notes ................................................................................................................................................. 10
4.7 Emissions during Operation ....................................................................................................................................... 11 4.8 Air Conditioning.............................................................................................................................................................. 11
4.8.1 Air Conditioning System.......................................................................................................................... 11 4.8.2 Room ventilation ........................................................................................................................................ 11 4.8.3 Connection of an Exhaust on the Laser Exhaust Duct
(only for machines with gaslaser) ........................................................................................................ 12 4.9 Operating Conditions.................................................................................................................................................... 13 4.10 Conditions for Storage and Transport..................................................................................................................... 13 4.11 Network Connection ..................................................................................................................................................... 13
5 Power Supply......................................................................................................................14 5.1 On-Site Connections ..................................................................................................................................................... 14 5.2 Connection Values, Connection Voltages, Connection Types ...................................................................... 15 5.3 Fuse Protection ............................................................................................................................................................... 16 5.4 Grounding / Earth Connection.................................................................................................................................. 16
6 Checklist ............................................................................................................................17 6.1 Machine ............................................................................................................................................................................. 17 6.2 Delivery and Transport ................................................................................................................................................. 17 6.3 Supply Facilities.............................................................................................................................................................. 18 6.4 Training .............................................................................................................................................................................. 20 6.5 Consumables.................................................................................................................................................................... 21 6.6 Accessories / Hardware / Software ........................................................................................................................ 21 6.7 Preinstallation – Customer ........................................................................................................................................ 23
6.7.1 Supply systems – contractors ............................................................................................................... 23 6.7.2 Ordered consumables ............................................................................................................................... 24 6.7.3 Additional parts / hardware / software, ordered ........................................................................... 24 6.7.4 Scheduled installation date.................................................................................................................... 24
7 Ordering Aid .......................................................................................................................25 7.1 Ordering Aid d-lab.2/d-lab.2plus – Features and Accessories for 'basic' and 'select' Models ........ 25 7.2 Ordering Aid d-lab.2 ...................................................................................................................................................... 26
Contents d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
ii 2005-05-01 / PN 04100_01 AgfaPhoto
7.3 Ordering Aid d-lab.2plus.............................................................................................................................................. 30 7.4 Order Aid d-lab.2 & d-lab.2plus special version for 70mm film .................................................................. 34 7.5 Ordering Aid netlab.2plus basic ............................................................................................................................... 35 7.6 Ordering Aid for Network-Connected Image Processing Systems on the Minilab with
Remote Service............................................................................................................................................................... 36 7.7 Operation Manuals ........................................................................................................................................................ 37 7.8 Consumables ................................................................................................................................................................... 37
8 Technical Data.................................................................................................................... 41 8.1 Machine versions ........................................................................................................................................................... 41 8.2 Complete System........................................................................................................................................................... 41 8.3 Main Computer ............................................................................................................................................................... 45 8.4 Prescanner / Scanner
Applies only to d-lab.2/2plus......................................................................................................................................... 46 8.5 Printer................................................................................................................................................................................. 47 8.6 Paper Processor .............................................................................................................................................................. 48 8.7 Heat Emission.................................................................................................................................................................. 49 8.8 Other Data ........................................................................................................................................................................ 49
9 Index.................................................................................................................................. 50
■
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation General
AgfaPhoto 2005-05-01 / PN 04100_01 1
1 General
1.1 Validity of this documentation
The Service Manual Preinstallation applies to the following machines:
Machines with gas laser:
d-lab.2 type 8060/260
d-lab.2plus type 8060/261
Machines with solid state laser:
d-lab.2 select type 8060/803 and type 8060/804
d-lab.2 basic type 8060/270 and type 8060/272
d-lab.2 (70mm) type 8060/157 + 8060/255
d-lab.2plus select type 8060/813 and type 8060/814
d-lab.2plus basic type 8060/271 and type 8060/273
d-lab.2plus (70mm) type 8060/158 + 8060/255
netlab.2plus basic type 8060/505
1.2 Preparation by the Customer
The preinstallation is under the responsibility of the customer as well as of an authorized local electrician. They must provide for a smooth installation by carrying out the following preliminary jobs in the given order:
– Preinstallation jobs carried out with care and completely terminated.
– All connections and facilities checked.
– Checklist (see further back) fully completed and returned to the AgfaPhoto Service about two weeks before the installation.
1.3 Measures by the AgfaPhoto Technician
The AgfaPhoto Technician performs the following assignments at the agreed time:
– Installation of the machine
– Mixing and filling in the chemistry (in collaboration with the customer and/or operator).
– Mechanical and electrical functional tests of the machine.
– Production check
– Brief introduction of the handling for the customer or operator. Explanation of the measures required in case of problems.
Machine Dimensions and Weight d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
2 2005-05-01 / PN 04100_01 AgfaPhoto
2 Machine Dimensions and Weight
2.1 Machine Dimensions and Weight, Packed
The shipment comprises of several boxes:
Applies to d-lab.2
Length Width Height Weight
Printer 1,560 mm 1,130 mm 1,840 mm 614 kg
Paper Processor 1,870 mm 1,170 mm 1,710 mm 544 kg
Accessory Box: 1,200 mm 800 mm 1,000 mm approx. 50 kg
Applies to d-lab.2plus
Length Width Height Weight
Printer 1,560 mm 1,130 mm 1,840 mm 637 kg
Paper Processor 1,870 mm 1,170 mm 1,710 mm 544 kg
Accessory Box: 1,200 mm 800 mm 1,000 mm approx. 50 kg
Applies to netlab.2plus
Length Width Height Weight
Printer 1,560 mm 1,130 mm 1,840 mm 540 kg
Paper Processor 1,870 mm 1,170 mm 1,710 mm 540 kg
Accessory Box: 1,200 mm 800 mm 1,000 mm approx. 50 kg
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Machine Dimensions and Weight
AgfaPhoto 2005-05-01 / PN 04100_01 3
2.2 Machine Dimensions, Unpacked Applies to d-lab.2
Printer
– Length: 1,280 mm
– Width: Applies to d-lab.2 with gas laser (Printer type 8060/150) 770 mm without table 870 mm with mounted table 1,010 mm with film collecting box and laser exhaust Applies to d-lab.2 with solid state laser (Printer type 8060/155 and 8060/157) 770 mm without table 870 mm with mounted table 920 mm with film collecting box
– Height: 1,530 mm
Paper Processor
– Length: 1,160 mm (incl. sorter 1560 mm)
– Width: 880 mm
– Height: 1,450 mm (opened 1,860 mm)
G_GG201
Complete machine
– Length: 2,840 mm (incl. Sorter) + 350 mm optional working table
– Width: Applies to d-lab.2 with gas laser (type 8060/260) 1,010 mm with film collecting box and laser exhaust Applies to d-lab.2 with solid state laser (Type 8060/803, 8060/804, 8060/270, 8060/272 and 8060/157+8060/255) 920 mm with film collecting box
– Height: 1,530 mm
Machine Dimensions and Weight d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
4 2005-05-01 / PN 04100_01 AgfaPhoto
Applies to d-lab.2plus
Printer
– Length: 1,280 mm
– Width: Applies to d-lab.2plus with gas laser (Printer type 8060/151) 770 mm without table 870 mm with mounted table 1,010 mm with film collecting box and laser exhaust Applies to d-lab.2plus with solid state laser (Printer type 8060/156 and 8060/158) 770 mm without table 870 mm with mounted table 920 mm with film collecting box
– Height: 1,530 mm
Paper Processor
– Length: 1,160 mm (incl. sorter 1560 mm)
– Width: 880 mm
– Height: 1,450 mm (opened 1,860 mm)
G_GG101
Complete machine
– Length: 2,840 mm (incl. Sorter) + 350 mm optional working table
– Width: Applies to d-lab.2plus with gas laser (type 8060/261) 1,010 mm with film collecting box and laser exhaust Applies to d-lab.2plus with solid state laser (type 8060/813, 8060/814, 8060/271, 8060/273 and 8060/158+8060/255) 920 mm with film collecting box
– Height: 1,530 mm
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Machine Dimensions and Weight
AgfaPhoto 2005-05-01 / PN 04100_01 5
Applies to netlab.2plus
Printer
– Length: 1,280 mm
– Width: 770 mm without table 870 mm with mounted table
– Height: 1,450 mm mm (with Monitor 1500mm)
Paper Processor
– Length: 1,160 mm (incl. sorter 1560 mm)
– Width: 880 mm
– Height: 1,450 mm (opened 1,860 mm)
G_GG101b
Complete machine
– Length: 2,840 mm (incl. Sorter) + 350 mm optional working table
– Width: 770 mm without table 870 mm with mounted table 1060 mm at the sorter
– Height: 1,500 mm (with monitor)
Machine Dimensions and Weight d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
6 2005-05-01 / PN 04100_01 AgfaPhoto
2.3 Weight, Unpacked Applies to d-lab.2
Complete machine: empty: approx. 910 kg filled: approx. 1,055 kg
Printer part: approx. 500 kg
Paper Processor part: empty approx. 410 kg filled approx. 555 kg
Applies to d-lab.2plus
Complete machine: empty: approx. 922 kg filled: approx. 1,067 kg
Printer part: approx. 512 kg
Paper Processor part: empty approx. 410 kg filled approx. 555 kg
Applies to netlab.2plus
Complete machine: empty: approx. 855 kg filled: approx. 1,000 kg
Printer part: approx. 445 kg
Paper Processor part: empty approx. 410 kg filled approx. 555 kg
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Transport
AgfaPhoto 2005-05-01 / PN 04100_01 7
3 Transport Printer and Paper Processor are supplied separately and can be pushed separately to the installation site. The following prerequisites must be checked and satisfied prior to delivery:
– Doors at least 0.95 m wide and 1.85 m high
4 Operation Site
4.1 Separation of the Food Section
CAUTION! Food must not be contaminated by photo-chemicals, or the waste or the emissions thereof (risk of poisoning). The operation site of the Minilab must be kept separate from the sales and stock area for foods and snacks, e.g. by a separating wall or facilities having a similar effect.
4.2 Room Requirements
– Room height at least 2.15 m (for removal of racks)
– Minimum floor load capacity 500 kg/m²
– The floor and the walls should be easy to clean
– Floor conditions:
– preferably waterproof concrete
– resistant to water and photo-chemicals
– even (no inclination, uneven spots, etc.)
Operation Site d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
8 2005-05-01 / PN 04100_01 AgfaPhoto
4.3 Required Space for Operation, Maintenance, and Service
320 cm 60 cm110 cm
77 cm
15 cm
87 cm
90 cm
AB
G_GG129
A Hot air extraction (for laser exhaust = 220 m³/h (only machines with Gaslaser: d-lab.2 Type 8060/260 d-lab.2plus Type 8060/261)
B Power connection
The following free space must be reserved for operation, maintenance, and service: – Complete floor space: 4.90 m x 1.82 m, approx. 9 m²
– Free space around the machine (for operation):
– Left: 110 cm
– Right: 60 cm
– Front: 90 cm
– Rear: 15 cm
Note Installation and Service require a distance from the wall of approx. 60 cm.
Note The power connection for the machine is located on the Paper Processor (B).
Furthermore storage space is required for photo-paper and photo-chemicals. Storage conditions:
– All photographic papers must always be stored in a cool and dry place. An ideal storage temperature is between +2 °C and +10 °C. Storage at 20 °C is possible for a few days without any problems. Storage temperatures above 30 ºC should be avoided as they will cause visible changes after only a few days.
– Opened packages have to be stored at a relative humidity of 50-60%.
Loading the paper in paper magazines requires a darkroom or a comparable facility (e.g. dark-tent).
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Operation Site
AgfaPhoto 2005-05-01 / PN 04100_01 9
4.4 Room Lighting
The room must be sufficiently illuminated and – if there is no daylight available – a light source comparable to daylight must be provided to be able to evaluate the color rendering in the prints.
The use of daylight fluorescent lamps is recommended (400-1,000 Lux).
Direct sunlight must be avoided.
The maximum illumination of 10,000 Lux must not be exceeded.
4.5 Water Connection, Cleaning Sink
Water connection and cleaning sink on the operation site are required for mixing the chemical solutions and for cleaning routines. We also recommend to provide for a warm water connection (approx. 30 °C), however, this is not a must.
The Minilab does not need a direct water connection, but this option is an available accessory (order number see Ordering Aid / Optional Accessories).
Operation Site d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
10 2005-05-01 / PN 04100_01 AgfaPhoto
4.6 Chemicals
4.6.1 Legal Regulations
The machine is subject to the legal regulations for water. Make sure that the following conditions can be satisfied:
– Chemicals must not be drained into the public sewage system.
– Check whether residual substances can be avoided, reduced or recycled.
– All photographic solutions, chemical filter cartridges, as well as plastic containers with harmful residues are considered hazardous waste and must be disposed of in compliance with legal regulations.
– Keep exhausted chemicals in suitable containers until their final disposal.
– When storing exhausted processing solutions, ensure that no waters are polluted, e.g. by unintentional leakage.
Note The regulations for handling and correct disposal of chemicals vary from country to country. Information about the regulations in force can be obtained from:
– the country’s authorities in charge;
– the nearest AgfaPhoto subsidiary.
4.6.2 Safety Notes
CAUTION! In the working area of the machine there are some slightly poisonous, irritating and caustic substances. The owner (employer)
– has to elaborate operation instructions for the handling of dangerous substances and
– provides for the instruction of his staff at least once a year;
– ensures sufficient ventilation: The air in industrial workrooms should be exchanged at least eight to ten times per hour.
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Operation Site
AgfaPhoto 2005-05-01 / PN 04100_01 11
4.7 Emissions during Operation
Photochemical solutions may discharge gases into the air. Some gases have a very low odor level. In unfavorable cases this may result in bad odor although the maximum working site concentration (max. value) has not yet been reached. Bad odors may be avoided by sufficient room ventilation and/or air conditioning.
4.8 Air Conditioning
4.8.1 Air Conditioning System
During operation the minilab produces heat (details see Technical data)
Machines with gas laser:
d-lab.2 Type 8060/260 d-lab.2plus Type 8060/261
appr. 5.500 kcal/h
Machines with solid state laser:
d-lab.2 select Type 8060/803 and Type 8060/804 d-lab.2 basic Type 8060/270 and Type 8060/272 d-lab.2 (70mm) Type 8060/157 + 8060/255 d-lab.2plus select Type 8060/813 and Type 8060/814 d-lab.2plus basic Type 8060/271 and Type 8060/273 d-lab.2plus (70mm) Type 8060/158 + 8060/255 netlab.2plus basic Type 8060/505
appr. 4.640 kcal/h
Therefore we recommend to install air conditioning, which guarantees for the required room climate (room temperature and humidity) (see sections Room ventilation and Operating conditions).
The laser exhaust (only d-lab.2 with gas laser, Type 8060/260, and d-lab.2plus with gas laser, Type 8060/261) can be extracted separately (see Connection of an exhaust on the laser exhaust duct)
Regular exchange of the air volume in the work rooms is necessary.
Note The wet section of the Paper Processor is sealed. The exhaust air generated here is negligible. Hence, the connection of an air exhaust is not necessary in this area.
4.8.2 Room ventilation
Ventilation should be sufficient so that the maximum working site concentration is not exceeded.
Observe national regulations!
Operation Site d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
12 2005-05-01 / PN 04100_01 AgfaPhoto
4.8.3 Connection of an Exhaust on the Laser Exhaust Duct (only for machines with gaslaser)
Applies only to d-lab.2 type 8060/260 and d-lab.2plus type 8060/261
not applicable for machines with solid state laser (d-lab.2 type 8060/803, 8060/804, 8060/270, 8060/272 und 8060/157+8060/255, d-lab.2plus type 8060/813, 8060/814, 8060/271, 8060/273 und 8060/158+8060/255) netlab.2plus type 8060/505)
5
3
3
4
6
2
1
7
G_GG402
1 Air supply for Printer power supply
2 Exhaust laser and Printer power supply
3 Air supply laser
4 Air supply Printer
5 Exhaust laser
6 Exhaust Printer
7 Exhaust Paper Processor
Pos. 3 and 5 are omitted in machines with solid state lasers
The fan of the laser power supply generates an air stream of 220 m³/h.
An exhaust hose can be connected on rectangular connection piece (5) located on the Printer rear panel.
An adapter for the connection to an air exhaust hose with a diameter of 125 mm is available: Type 8060/350, order number (ABC-Code) 5GVP2.
CAUTION! Never use an exhaust hose smaller than 125 mm in diameter. This would cause heat accumulation resulting in a reduced life span of the laser!
Note The wet section of the Paper Processor is sealed. The exhaust air generated here is negligible. Hence, the connection of an air exhaust is not necessary in this area.
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Operation Site
AgfaPhoto 2005-05-01 / PN 04100_01 13
4.9 Operating Conditions
The following conditions must be met for operation of the Minilab:
Room temperature: +15 °C to +30 °C
Relative humidity: 15% to 85%
Noise level: < 70 dB(A)
Maximum ambient light:
Printer + Paper Processor: 10,000 Lux
Paper magazines: 20,000 Lux
CAUTION! This machine is a Class A equipment according to EN 55022. This equipment may cause radio interference in residential areas. In this case the user may be required to initiate respective measures and pay for those.
4.10 Conditions for Storage and Transport
The following conditions must be met for storage and transport of the Minilab:
Temperature range: -50 °C to +60 °C
Relative humidity: 15% to 90%
4.11 Network Connection
The Minilab can be connected to one Workstation in the lab. For communication it uses the Software d-workflow / d-bridge, which must be installed in the Workstation. A Workstation with this installation provides printable, externally created orders, which were sent to the d-workflow / d-bridge, for collection by the Minilab.
And vice versa the Minilab can send image files to a workstation and save the files there.
Network setup is the responsibility of the customer. AgfaPhoto supplies the required software (see Ordering aid for network-connected image processing systems).
Power Supply d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
14 2005-05-01 / PN 04100_01 AgfaPhoto
5 Power Supply
5.1 On-Site Connections
CAUTION! The permanent on-site connection must be made by an authorized electrician who is also responsible for this job.
The connections for the machine must be installed by a local electrician according to the data listed in the following sections. Thereby the following facts should be considered: – The power connecting cable must be run up to the Minilab.
– Plan for a circuit breaker to cut the machine off the mains.
– If you want to use the integrated strain-relief consider the outer diameter of the power cable. This must be within a range of at least 13 mm to maximum 18 mm.
– For the connection of the PE conductor, a cable lug with a hole diameter of about 6 mm must be used or, if solid conductors (wires) are used, an appropriate lug must be bent.
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Power Supply
AgfaPhoto 2005-05-01 / PN 04100_01 15
5.2 Connection Values, Connection Voltages, Connection Types
We recommend a 3-phase operation, single-phase operation is possible.
CAUTION! Make sure that the line section of the on-site installation and the connecting cable is sufficient! In case of an insufficient cable cross-section the cable get hot: risk of fire.
Connection type
Pictograph Nominal supply voltage
Nominal frequency
Nominal current Site connection, fuse protection
3W + N + PE
220/380 V 230/400 V 240/415 V
50/60 Hz 16 A 3 x 16 A
3W + PE
200 V 210 V 220 V 230 V 240 V
50/60 Hz 25 A 3 x 25 A
2W + PE 1W + N + PE
200 V 210 V 220 V 230 V 240 V
50/60 Hz 32 A 1 x 32 A
CAUTION! Only the values listed in the table above may be applied between phase and neutral, or if there is no neutral, between phase and phase.
CAUTION! For operation with 50 Hz mains: single-phase connection is only permitted for industrial networks. If the machine is connected to a public low-voltage network the connection must always be a 3-phase connection (as required by IEC 61000-3-3).
Power Supply d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
16 2005-05-01 / PN 04100_01 AgfaPhoto
5.3 Fuse Protection
Fuse protection for the on-site connection: see table on previous page.
Note Due to induction the intensity of the current flowing at the moment of switch-on is a multiple of the normal current. The magnetizing current (rush effect) of the transformer rises considerably and may trigger the lab fuse. We recommend to use a safety circuit breaker with slow trigger characteristics.
5.4 Grounding / Earth Connection
The Minilabmust be earthed directly and correctly.
HOHER ABLEITSTROM
Vor Inbetriebnahme
Erdverbindung herstellen!
HIGH LEAKAGE CURRENT
Earth connection before
connecting supply !
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Checklist
AgfaPhoto 2005-05-01 / PN 04100_01 17
6 Checklist The completed checklist must be returned to the AgfaPhoto Service in charge no later than two weeks prior to the scheduled installation date. Only if all conditions listed below have been satisfied and this has been confirmed by the customer writing, the installation can be made at the scheduled date.
If individual points or all of the conditions below have been neglected this causes a delay and/or additional expenditure for the Service, which can be charged to the customer.
6.1 Machine
The following machine should be delivered and installed:
d-lab.2
d-lab.2plus
netlab.2plus
6.2 Delivery and Transport
Yes No
Delivery
The customer ensures free access for the delivery day
Can the delivery truck drive up to the entrance?
Transport
Access to the operation site on ground floor? If NOT, describe the delivery and transport situation:
Machine must transported upstairs / downstairs: Number of floors / stairs _____ / _____
Freight elevator present?
Loading zone present?
Fork lift / crane required?
Doors must be removed?
Windows must be removed?
Transport across uneven floor, thresholds, etc.?
Inspection by forwarder required prior to the installation?
Remarks: __________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
Access to the operation site: Height and width of hallways and doors meet the minimum requirements? (door width min. 0.95 m, height 1.85 m)
Checklist d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
18 2005-05-01 / PN 04100_01 AgfaPhoto
6.3 Supply Facilities
Yes No
Illumination
Maximum light intensity of 10,000 Lux is not exceeded?
Production area is sufficiently illuminated for evaluation of the printed production? (day light fluorescent light)
Machine is not exposed to direct sunlight at the operation site?
Remarks: ______________________________________________________________________
______________________________________________________________________________
Space requirements for operation and service
Enough space available around the machine for operation and service (at least. 4.90 m x 1.82 m – see drawing and Required Space for Operation, Maintenance, and Service)?
320 cm 60 cm110 cm
77 cm
15 cm
87 cm
90 cm
AB
G_GG129
A Hot air extraction (for laser exhaust = 220 m³/h (only machines with Gaslaser: d-lab.2 Type 8060/260, d-lab.2plus Type 8060/261)
B Power connection
Ceiling height meets the requirements (at least 2.15 m)?
Darkroom or dark tent present?
Remarks: __________________________________________________________________
______________________________________________________________________________
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Checklist
AgfaPhoto 2005-05-01 / PN 04100_01 19
Yes No
Floor conditions
Floor load meats the requirements (at least 500 kg/m²)?
Floor covering meets the requirements? (resistant to water and chemicals; no carpet)
Even floors? (no inclination, raised or uneven spots, et.)
Remarks: __________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
Darkroom / dark tent
Is a darkroom or dark tent available to load the paper rolls?
Disposal of chemicals
The customer is familiar with the local regulations regarding the disposal and made the required preparations?
Air conditioning and room aeration
Operating area has sufficient aeration / air conditioning to ensure the required room temperature and humidity?
Applies only to machines with gas laser (d-lab.2 type 8060/260 and d-lab.2plus type 8060/261) Warm air extraction for laser exhaust (220 m³ / h; connection position see A in the illustration, previous page) or air conditioning.
Air exhaust adapter ∅ 125 mm, Type 8060/350
The customer is familiar with the local regulations regarding the regular exchange of air in working rooms and made the required preparations?
Remarks: __________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
Checklist d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
20 2005-05-01 / PN 04100_01 AgfaPhoto
Yes No
Water supply
Customer wants a direct water connection to the machine? Order the water connection kit (optional accessory) before the installation!
Water connection for chemical mixing and for cleaning or maintenance work available? Distance to the machine: ________
Cleaning sink available near the machine?
Remarks: __________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
Power connection
The customer is familiar with requirements and ensures that all preparations are made prior to the installation (supply cable must be installed all the way to the machine; connection position: see
B, drawing in section Supply Facilities)? Configuration: _____________________
Remarks: __________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
Telephone connection
The customer is familiar with the requirements and makes sure that the respective work is completed prior to the installation?
Remarks: __________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
Network connection
The customer is familiar with the requirements and makes sure that the respective work is completed prior to the installation?
Remarks: __________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
6.4 Training
Yes No
Training
Necessary training has been discussed with the customer?
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Checklist
AgfaPhoto 2005-05-01 / PN 04100_01 21
6.5 Consumables
Yes No
Consumables
The customer uses AgfaPhoto paper and chemicals?
In case of Yes: In case of No:
Tank kits ordered?
Easy paper boxes ordered?
Chemical control strips ordered?
Paper ordered?
Requirements discussed with the customer? The customer is informed about the consumables which must be present at the time of installation?
Remarks: __________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
6.6 Accessories / Hardware / Software
Yes No
Accessories / Hardware / Software
Requirements have been discussed with the customer? The customer is informed about the prerequisites for the installation?
Remarks: __________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
General remarks:_________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
Scheduled delivery date:___________________________
Scheduled installation date:______________________
___________________________________________ ____________________________________________
AgfaPhoto representative Customer
Checklist d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
22 2005-05-01 / PN 04100_01 AgfaPhoto
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Checklist
AgfaPhoto 2005-05-01 / PN 04100_01 23
6.7 Preinstallation – Customer
6.7.1 Supply systems – contractors
Electrical connections
Contractor appointed to do the installation:
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
Date: __________________________________________________________
Water / waste water
Contractor appointed to do the installation:
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
Date: __________________________________________________________
Air conditioning / room ventilation
Contractor appointed to do the installation:
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
Date: __________________________________________________________
Telephone connection
Contractor appointed to do the installation:
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
Date: __________________________________________________________
Network connection
Contractor appointed to do the installation:
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
Date: __________________________________________________________
Checklist d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
24 2005-05-01 / PN 04100_01 AgfaPhoto
6.7.2 Ordered consumables
Delivery date
Tank kits ordered? ____________________
Easy paper boxes ordered? ____________________
Chemical control strips ordered? ____________________
Paper ordered? ____________________
6.7.3 Additional parts / hardware / software, ordered
Delivery date
_________________________________________ ____________________
_________________________________________ ____________________
_________________________________________ ____________________
_________________________________________ ____________________
_________________________________________ ____________________
_________________________________________ ____________________
_________________________________________ ____________________
_________________________________________ ____________________
_________________________________________ ____________________
_________________________________________ ____________________
6.7.4 Scheduled installation date
____________________
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Ordering Aid
AgfaPhoto 2005-05-01 / PN 04100_01 25
7 Ordering Aid
7.1 Ordering Aid d-lab.2/d-lab.2plus – Features and Accessories for 'basic' and 'select' Models
d-lab.2/d-lab.2plus basic
d-lab.2/d-lab.2plus select
scanner/printer/paper processor ● ● 2 paper magazines ○ ● negative carrier 135 ● ● negative carrier APS ○ ● auxiliary shelf ○ ● reorder keyboard ○ ● passport/combi print option ○ ● slide film option (135/120 unmounted) ○ ● slide carrier (135 mounted) ○ ○ scratch correction for CN film ● ● scratch correction for slide film ○ ● a-REDC red eyes correction ○ ● 6"x12" sorter * ● ● 10"x12" sorter * ● ●
Legend: ● = standard feature/accessory
○ = optional feature/accessory * = depending on the ordered type, 6" or 10" sorter
Ordering Aid d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
26 2005-05-01 / PN 04100_01 AgfaPhoto
7.2 Ordering Aid d-lab.2
d-lab.2 select (6" Sorter)1 Type no.
8060/804 Order no. 5LTJF
consists of number
d-lab.2 Printer 2004*, Paper Processor, Sorter 6" 10 Trays 1
Auxiliary Shelf 1
Paper Magazine 8" incl. 4,5" 1
Paper Magazine 12" incl. 4,5" 1
Reorder Keyboard 1
Neg. Carrier IX240 (APS) 1
passport/combi print 1
slide film unmounted**** 1
scratch correction slide 1
red eyes correction (a-RECD) 1
d-lab.2 select (10" Sorter)1 Type no. 8060/803
Order no. 5LKW4
consists of number
d-lab.2 Printer 2004*, Paper Processor, Sorter 10" 10 Trays 1
Auxiliary Shelf 1
Paper Magazine 8" incl. 4,5" 1
Paper Magazine 12" incl. 4,5" 1
Reorder Keyboard 1
Neg. Carrier IX240 (APS) 1
passport/combi print 1
slide film unmounted**** 1
scratch correction slide 1
red eyes correction (a-RECD) 1
1 d-lab.2 select does not include monitor! Please choose one of the two following items:
type no. Order no. number
Touch Screen Monitor LCD (Flat Screen) 8060/341 5FLPM 1
Touch Screen Monitor CRT1 8060/340 5FLOK 1
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Ordering Aid
AgfaPhoto 2005-05-01 / PN 04100_01 27
Options for d-lab.2 select type no. Order no. number
USB Modem for Remote Service Access (CE/ENEC) 8060/311 5H1U7 1
Paper Magazine 8" incl. 4,5" 8060/361 5H9LN
Paper Magazine 12" incl. 4,5" 8060/362 5J4J5
Pricing Unit (CE/TÜV)*** 8506/181 B7256
Pricing Unit (UL)*** 8506/182 B9M81
Neg. Carrier 135H 8506/136 B72N5
Neg. Carrier 110 8506/139 B72QC
Mirror Box 120 8060/380 5HTEG
Neg. Carrier 120 6x4,5 8506/165 B72TJ
Neg. Carrier 120 6x6 8506/166 B72UL
Neg. Carrier 120 6x7 8506/167 B72VN
Neg. Carrier 120 6x8 8506/168 B72WP
Neg. Carrier 120 6x9 8506/169 B72XR
Slide Carrier (incl. scanner filters) 8060/330 5FLNH
Software Licences for d-lab
Pricing d-lab (w/o label printer) 8060/400 5HUBE
Index Print Import d-lab 8060/401 5HUCG
Statistics Save d-lab 8060/403 5H1A2
External water connection d-lab.2 8060/351 5H12N
1 d-lab.2 select does not include monitor
* includes 135 negative carrier and universal lens
*** additional billable software licence "Pricing d-lab" 8060/400 (5HUBE) required
**** option requires either slide carrier (incl. scanner filters) 8060/330 (5FLNH) or slide scanner filters (available as single service spare parts)
Ordering Aid d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
28 2005-05-01 / PN 04100_01 AgfaPhoto
d-lab.2 basic (6" Sorter) type no. Order no. number
The following 4 items are required to run a d-lab.2:
d-lab.2 Printer 2004*, Paper Processor, Sorter 6" 10 Trays
8060/270 5LKSV 1
Paper Magazine 8" incl. 4,5" 8060/361 5H9LN 1
Paper Magazine 12" incl. 4,5" 8060/362 5J4J5 1
Touch Screen Monitor CRT 8060/340 5FLOK 1
d-lab.2 basic (10" Sorter) type no. Order no. number
The following 4 items are required to run a d-lab.2:
d-lab.2 Printer 2004*, Paper Processor, Sorter 10" 10 Trays
8060/272 5LKUZ 1
Paper Magazine 8" incl. 4,5" 8060/361 5H9LN 1
Paper Magazine 12" incl. 4,5" 8060/362 5J4J5 1
Touch Screen Monitor CRT 8060/340 5FLOK 1
Options for d-lab.2 basic type no. Order no. number
USB Modem for Remote Service Access (CE/ENEC) 8060/311 5H1U7
Touch Screen Monitor LCD (Flat Screen)** 8060/341 5FLPM
Auxiliary Shelf 8060/320 5FDHC
Reorder Keyboard 8070/700 5KXZN
Paper Magazine 8" incl. 4,5" 8060/361 5H9LN
Paper Magazine 12" incl. 4,5" 8060/362 5J4J5
Pricing Unit (CE/TÜV)*** 8506/181 B7256
Pricing Unit (UL)*** 8506/182 B9M81
Neg. Carrier 135H 8506/136 B72N5
Neg. Carrier 110 8506/139 B72QC
Neg. Carrier IX240 (APS) 8506/140 B72RE
Mirror Box 120 8060/380 5HTEG
Neg. Carrier 120 6x4,5 8506/165 B72TJ
Neg. Carrier 120 6x6 8506/166 B72UL
Neg. Carrier 120 6x7 8506/167 B72VN
Neg. Carrier 120 6x8 8506/168 B72WP
Neg. Carrier 120 6x9 8506/169 B72XR
Slide Carrier (incl. scanner filters) 8060/330 5FLNH
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Ordering Aid
AgfaPhoto 2005-05-01 / PN 04100_01 29
Options for d-lab.2 basic (cont.) type no. Order no. number
Software Licences for d-lab
Pricing d-lab (w/o label printer) 8060/400 5HUBE
Index Print Import d-lab 8060/401 5HUCG
Passport/Combi Print d-lab 8060/402 5HZ9X
Statistics Save d-lab 8060/403 5H1A2
passport/combi print 8060/402 5HZ9X
slide film unmounted**** 8070/604 5LRG2
scratch correction slide 8070/605 5LRH4
red eyes correction (a-RECD) 8070/606 5LRJ6
External water connection d-lab.2 8060/351 5H12N
* includes 135 negative carrier and universal lens
** LCD Monitor will be delivered instead of the CRT Monitor.
*** additional billable software licence "Pricing d-lab" 8060/400 (5HUBE) required
**** option requires either slide carrier (incl. scanner filters) 8060/330 (5FLNH) or slide scanner filters (available as single service spare parts)
Ordering Aid d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
30 2005-05-01 / PN 04100_01 AgfaPhoto
7.3 Ordering Aid d-lab.2plus
d-lab.2plus select (6" Sorter)1 Type no. 8060/814
Order no. 5LTKH
consists of number
d-lab.2plus Printer 2004*, Paper Processor, Sorter 6" 13 Trays 1
Auxiliary Shelf 1
Paper Magazine 12" incl. 4,5" 2
Reorder Keyboard 1
Neg. Carrier IX240 (APS) 1
passport/combi print 1
slide film unmounted**** 1
scratch correction slide 1
red eyes correction (a-RECD) 1
d-lab.2plus select (10" Sorter)1 Type no. 8060/813
Order no. 5LKX6
consists of number
d-lab.2plus Printer 2004*, Paper Processor, Sorter 10" 10 Trays 1
Auxiliary Shelf 1
Paper Magazine 12" incl. 4,5" 2
Reorder Keyboard 1
Neg. Carrier IX240 (APS) 1
passport/combi print 1
slide film unmounted**** 1
scratch correction slide 1
red eyes correction (a-RECD) 1
1 d-lab.2plus select does not include monitor! Please choose one of the two following items:
type no. Order no. number
Touch Screen Monitor LCD (Flat Screen) 8060/341 5FLPM 1
Touch Screen Monitor CRT1 8060/340 5FLOK 1
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Ordering Aid
AgfaPhoto 2005-05-01 / PN 04100_01 31
Options for d-lab.2plus select type no. Order no. number
USB Modem for Remote Service Access (CE/ENEC) 8060/311 5H1U7
Paper Magazine 12" incl. 4,5" 8060/362 5J4J5
Pricing Unit (CE/TÜV)*** 8506/181 B7256
Pricing Unit (UL)*** 8506/182 B9M81
Neg. Carrier 135H 8506/136 B72N5
Neg. Carrier 110 8506/139 B72QC
Mirror Box 120 8060/380 5HTEG
Neg. Carrier 120 6x4,5 8506/165 B72TJ
Neg. Carrier 120 6x6 8506/166 B72UL
Neg. Carrier 120 6x7 8506/167 B72VN
Neg. Carrier 120 6x8 8506/168 B72WP
Neg. Carrier 120 6x9 8506/169 B72XR
Slide Carrier (incl. scanner filters) 8060/330 5FLNH
Software Licences for d-lab
Pricing d-lab (w/o label printer) 8060/400 5HUBE
Index Print Import d-lab 8060/401 5HUCG
Statistics Save d-lab 8060/403 5H1A2
External water connection d-lab.2plus 8060/351 5H12N
1 d-lab.2plus select does not include monitor
* includes 135 negative carrier and universal lens
*** additional billable software licence "Pricing d-lab" 8060/400 (5HUBE) required
**** option requires either slide carrier (incl. scanner filters) 8060/330 (5FLNH) or slide scanner filters (available as single service spare parts)
Ordering Aid d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
32 2005-05-01 / PN 04100_01 AgfaPhoto
d-lab.2plus basic (6" Sorter) type no. Order no. number
The following 3 items are required to run a d-lab.2plus:
d-lab.2plus Printer 2004*, Paper Processor, Sorter 6" 13 Trays
8060/271 5LKTX 1
Paper Magazine 12" incl. 4,5" 8060/362 5J4J5 2
Touch Screen Monitor CRT 8060/340 5FLOK 1
d-lab.2plus basic (10" Sorter) type no. Order no. number
The following 3 items are required to run a d-lab.2plus:
d-lab.2plus Printer 2004*, Paper Processor, Sorter 10" 10 Trays
8060/273 5LKV2 1
Paper Magazine 12" incl. 4,5" 8060/362 5J4J5 2
Touch Screen Monitor CRT 8060/340 5FLOK 1
Options for d-lab.2plus basic type no. Order no. number
USB Modem for Remote Service Access (CE/ENEC) 8060/311 5H1U7
Touch Screen Monitor LCD (Flat Screen)** 8060/341 5FLPM
Auxiliary Shelf 8060/320 5FDHC
Reorder Keyboard 8070/700 5KXZN
Paper Magazine 12" incl. 4,5" 8060/362 5J4J5
Pricing Unit (CE/TÜV)*** 8506/181 B7256
Pricing Unit (UL)*** 8506/182 B9M81
Neg. Carrier 135H 8506/136 B72N5
Neg. Carrier 110 8506/139 B72QC
Neg. Carrier IX240 (APS) 8506/140 B72RE
Mirror Box 120 8060/380 5HTEG
Neg. Carrier 120 6x4,5 8506/165 B72TJ
Neg. Carrier 120 6x6 8506/166 B72UL
Neg. Carrier 120 6x7 8506/167 B72VN
Neg. Carrier 120 6x8 8506/168 B72WP
Neg. Carrier 120 6x9 8506/169 B72XR
Slide Carrier (incl. scanner filters) 8060/330 5FLNH
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Ordering Aid
AgfaPhoto 2005-05-01 / PN 04100_01 33
Options for d-lab.2plus basic (cont.) type no. Order no. number
Software Licences for d-lab
Pricing d-lab (w/o label printer) 8060/400 5HUBE
Index Print Import d-lab 8060/401 5HUCG
Passport/Combi Print d-lab 8060/402 5HZ9X
Statistics Save d-lab 8060/403 5H1A2
passport/combi print 8060/402 5HZ9X
slide film unmounted**** 8070/604 5LRG2
scratch correction slide 8070/605 5LRH4
red eyes correction (a-RECD) 8070/606 5LRJ6
External water connection d-lab.2plus 8060/351 5H12N
* includes 135 negative carrier and universal lens
** LCD Monitor will be delivered instead of the CRT Monitor.
*** additional billable software licence "Pricing d-lab" 8060/400 (5HUBE) required
**** option requires either slide carrier (incl. scanner filters) 8060/330 (5FLNH) or slide scanner filters (available as single service spare parts)
Ordering Aid d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
34 2005-05-01 / PN 04100_01 AgfaPhoto
7.4 Order Aid d-lab.2 & d-lab.2plus special version for 70mm film
d-lab.2 special version for 70mm film
type no. Order no. number
d-lab.2 Printer 70mm 2004** 8060/157 5LD82 1
d-lab.2(plus) Paper Processor (w/o sorter) 8060/255 5LKON 1
Sorter 6" 10 Trays 8060/290 5LKPP 1
Paper Magazine 8" incl. 4,5" 8060/361 5H9LN 1
Paper Magazine 12" incl. 4,5" 8060/362 5J4J5 1
Negative Carrier 70mm 6x6 8060/166 5K3G5 1
Touch Screen Monitor CRT 8060/340 5FLOK 1
Options type no. Order no. number
Sorter 10" 10 Trays* 8060/291 5LKQR
For further options please see "Options" on sheet "d-lab.2 basic"
d-lab.2plus special version for 70mm film
type no. Order no. number
d-lab.2plus Printer 70mm 2004** 8060/158 5LENY 1
d-lab.2(plus) Paper Processor (w/o sorter!) 8060/255 5LKON 1
Sorter 6" 13 Trays 8060/293 5LKRT 1
Paper Magazine 12" incl. 4,5" 8060/362 5J4J5 2
Negative Carrier 70mm 6x6 8060/166 5K3G5 1
Touch Screen Monitor CRT 8060/340 5FLOK 1
Options type no. Order no. number
Sorter 10" 10 Trays* 8060/291 5LKQR
For further options please see "Options" on sheet "d-lab.2plus basic"
* 10" sorter will be delivered instead of 6" sorter
** includes 135 negative carrier and universal lens
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Ordering Aid
AgfaPhoto 2005-05-01 / PN 04100_01 35
7.5 Ordering Aid netlab.2plus basic
The following 3 items are required to a run netlab.2plus:
type no. Order no. number
netlab.2plus Printer (w/o Paper Magazines), Paper Processor, 10" Sorter (10 Trays)
8060/505 5LL5Q 1
Paper Magazine 12" incl. 4,5" 8060/362 5J4J5 2
Touch Screen Monitor CRT 8060/340 5FLOK 1
Options type no. Order no. number
USB Modem for Remote Service Access (CE/ENEC) 8060/311 5H1U7
Touch Screen Monitor LCD (Flat Screen)** 8060/341 5FLPM
Auxiliary Shelf 8060/320 5FDHC
Paper Magazine 12" incl. 4,5" 8060/362 5J4J5
Pricing Unit (CE/TÜV)*** 8506/181 B7256
Pricing Unit (UL)*** 8506/182 B9M81
Software Licences for d-lab Pricing d-lab (w/o label printer) 8060/400 5HUBE
Index Print Import d-lab 8060/401 5HUCG
Passport/Combi Print d-lab 8060/402 5HZ9X
Statistics Save d-lab 8060/403 5H1A2
External water connection d-lab.2/.2plus 8060/351 5H12N
** LCD Monitor will be delivered instead of the CRT Monitor. *** additional billable software licence "Pricing d-lab" 8060/400 (5HUBE)
required
Ordering Aid d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
36 2005-05-01 / PN 04100_01 AgfaPhoto
7.6 Ordering Aid for Network-Connected Image Processing Systems on the Minilab with Remote Service
Type Order no.
Transfer Software for PC/Mac 8060/370 5GVQ4
Pixtasy 4.0 9975/170 5F5S3
d-workflow Software (only PC) —
AgfaPhotonet Print Service —
e-box 9977/100
USB modem 8060/311 5H1U7
Analog modem 56k (230 V, 50 Hz) DE+2984338
8-port Hub, 100 Mbps CM+7.0486.1344.0
Ethernet cable available lengths
5 m 10 m 15 m 20 m
CM+9.9999.1114.0 CM+9.9999.1115.0 CM+9.9999.1116.0 CM+9.9999.1117.0
Ethernet cable (cross connect) available lengths
2 m 5 m 10 m 15 m
CM+9.9999.1121.0 CM+9.8508.1294.0 CM+9.9999.1119.0 CM+9.9999.1120.0
Image editing/processing withoutPixtasy or e-box
Workstation PC/MAC must beprovided by the customerd-workflow (only PC)
Transfer Software forPC/MAC Cross Connect
Ethernet cable
Pixtasyd-workflow
e-box
AgfaNet + Pixtasyd-workflow
Remote Service,Net SupportManager (NSM)
d-lab
Cross ConnectEthernet cable
Cross ConnectEthernet cable
Cross ConnectEthernet cable
Ethernet8-port Hub 100 MbpsEthernet
Modem
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Ordering Aid
AgfaPhoto 2005-05-01 / PN 04100_01 37
7.7 Operation Manuals
The Operation Manuals – Operation sections, available by the order numbers mentioned below, apply to all minilabs d-lab.2, d-lab.2plus, and netlab.2plus.
Minilab Order no.
German DD+18060A161D0
English DD+18060A162D0
French DD+18060A163D0
Italian DD+18060A164D0
Spanish DD+18060A165D0
7.8 Consumables
Chemicals
The chemical kits mentioned below are used in all minilabs d-lab.2, d-lab.2plus, and netlab.2plus.
Order no.
d-lab.2 Easy Paper Box for 110 m² (2 boxes) 5KPGL
MSC 200/300/d-lab.2/d-lab.3 tank kit 5FFYK
MSC/d-lab tank CD for 2 x 18.5 liters: contains concentrate for two CD tank fillings
5HX5G
MSC/d-lab tank BX for 2 x 18 liters: contains concentrate for two BX tank fillings
5HX7L
MSC/d-lab tank SB for 12 x 11-12.5 liters: contains concentrate for three SB tank fillings
5HX8N
Ordering Aid d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
38 2005-05-01 / PN 04100_01 AgfaPhoto
Agfacolor Splendix Paper 310 glossy
Width [cm]
x Length [cm]
Width [inch]
x Length [inch]
Order number
Barcode (EAN)
Rolls per packing unit *
Packing units per pallet
8.9 x 183 3.5 x 600 5K5XD 4006353 427569 4 24
10.2 x 183 4 x 600 5K5YF 4006353 427576 4 24
12.7 x 183 5 x 600 5K5ZH 4006353 427583 2 36
15.2 x 183 6 x 600 5K51K 4006353 427590 2 30
17.8 x 91.5 7 x 300 5K52M 4006353 427606 4 24
20.3 x 91.5 8 x 300 5K53O 4006353 427613 4 18
25.4 x 91.5 10 x 300 5K54Q 4006353 427620 4 18
27.9 x 91.5 11 x 300 5K55S 4006353 427637 2 24
30.5 x 91.5 12 x 300 5K57W 4006353 427651 2 24
* minimum order amount: one packing unit
Agfacolor Splendix Paper 319 lustre
Width [cm]
x Length [cm]
Width [inch]
x Length [inch]
Order number
Barcode (EAN)
Rolls per packing unit *
Packing units per pallet
8.9 x 183 3,5 x 600 5K6Q2 4006353 427835 4 24
10.2 x 183 4 x 600 5K6R4 4006353 427842 4 24
12.7 x 183 5 x 600 5K6S6 4006353 427859 2 36
15.2 x 183 6 x 600 5K6T8 4006353 427866 2 30
17.8 x 91.5 7 x 300 5K6UB 4006353 427873 4 24
20.3 x 91.5 8 x 300 5K6VD 4006353 427880 4 18
25.4 x 91.5 10 x 300 5K6WF 4006353 427897 4 18
27.9 x 91.5 11 x 300 5K6XH 4006353 427903 2 24
30.5 x 91.5 12 x 300 5K6YK 4006353 427910 2 24
* minimum order amount: one packing unit
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Ordering Aid
AgfaPhoto 2005-05-01 / PN 04100_01 39
Agfacolor Sensatis Paper 510 glossy
Width [cm]
x Length [cm]
Width [inch]
x Length [inch]
Order number
Barcode (EAN)
Rolls per packing unit *
Packing units per pallet
8.9 x 158 3,5 x 518 5K4NN 4006353 427125 4 24
10.2 x 158 4 x 518 5K4OP 4006353 427132 4 24
11.4 x 158 4,5 x 518 5K4PR 4006353 427149 2 30
12.7 x 158 5 x 518 5K4QT 4006353 427156 2 36
15.2 x 158 6 x 518 5K4RV 4006353 427163 2 30
17.8 x 79 7 x 259 5K4SX 4006353 427170
20.3 x 79 8 x 259 5K4TZ 4006353 427187 4 18
25.4 x 79 10 x 259 5K4U2 4006353 427194
30.5 x 79 12 x 259 5K4V4 4006353 427200 2 24
* minimum order amount: one packing unit
Agfacolor Sensatis Paper 519 lustre
Width [cm]
x Length [cm]
Width [inch]
x Length [inch]
Order number
Barcode (EAN)
Rolls per packing unit *
Packing units per pallet
8.9 x 158 3,5 x 518 5K5EA 4006353 427385 4 24
10.2 x 158 4 x 518 5K5FC 4006353 427392 4 24
12.7 x 158 5 x 518 5K5GE 4006353 427408 2 36
15.2 x 158 6 x 518 5K5HG 4006353 427415 2 30
17.8 x 79 7 x 259 5K5JJ 4006353 427422
20.3 x 79 8 x 259 5K5KL 4006353 427439 4 18
25.4 x 79 10 x 259 5K5LN 4006353 427446
30.5 x 79 12 x 259 5K5MP 4006353 427453 2 24
* minimum order amount: one packing unit
Ordering Aid d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
40 2005-05-01 / PN 04100_01 AgfaPhoto
Air filter Order no.
Lamphouse (only d-lab.2/2plus) CM+9.8061.LHL5.0
CCD(only d-lab.2/2plus) CM+9.8061.FEL4.0
Cutter area CM+9.7075.2731.0
Door to print engine (PE, d-lab.2) resp. print machine (PM, d-lab.2plus, netlab.2plus)
CM+9.8060.MUL8.1
Paper outlet (PO) CL+P4-4071(3/1)
Dryer CL+P4-E9249
AC supply CL+P4-E9249
Chemical filters and control strips Order no.
Chemical filters CD, BX, SB1, SB2, SB3, SB4 CL+P4-E0364
Chemical control strip 5HWGX
Other consumables Order no.
Back printer ink ribbon CM+9.8060.LDZF.1
Scanner lamp (only d-lab.2/2plus) CM+7.0450.6545.0
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Technical Data
AgfaPhoto 2005-05-01 / PN 04100_01 41
8 Technical Data
8.1 Machine versions
Machines with gas laser:
d-lab.2 Type 8060/260
d-lab.2plus Type 8060/261
Machines with solid state laser:
d-lab.2 select Type 8060/803 and Type 8060/804
d-lab.2 basic Type 8060/270 and Type 8060/272
d-lab.2 (70mm) Type 8060/157 + 8060/255
d-lab.2plus select Type 8060/813 and Type 8060/814
d-lab.2plus basic Type 8060/271 and Type 8060/273
d-lab.2plus (70mm) Type 8060/158 + 8060/255
netlab.2plus basic Type 8060/505
8.2 Complete System
Dimensions Applies to d-lab.2
Length: 2,840 mm (including sorter) + 350 mm for optional work table
Width: Applies to d-lab.2 with gas laser (type 8060/260) 1,010 with film collecting box and laser exhaust Applies to d-lab.2 with solid state laser(Type 8060/803, 8060/804, 8060/270, 8060/272 and 8060/157+8060/255) 920 mm with film collecting box
Height: 1,530 mm
Weight empty: approx. 910 kg
Weight filled: approx. 1, 055 kg
Technical Data d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
42 2005-05-01 / PN 04100_01 AgfaPhoto
Applies to d-lab.2plus
Length: 2,840 mm (including sorter) + 350 mm for optional work table
Width: Applies to d-lab.2plus with gas laser (Printer type 8060/261) 1,010 mm with film collecting box and air exhaust laser Applies to d-lab.2plus with solid state laser (type 8060/813, 8060/814, 8060/271, 8060/273 and 8060/158+8060/255) 920 mm with film collecting box
Height: 1,530 mm
Weight empty: approx. 922 kg
Weight filled: approx. 1,067 kg
Applies to netlab.2plus
Length: 2,840 mm (including sorter) + 350 mm for optional work table
Width: 770 mm without table top 870 mm with mounted table top) at the sorter 1060mm)
Height: 1,530 mm
Weight empty: approx. 855 kg
Weight filled: approx. 1,000 kg
General Applies to d-lab.2/2plus
Digital minilab to print negative films, slides, reversal films and images from digital sources (storage medium or network) and to save digital data on digital storage media or in a connected network
Prescan with AgfaPhoto TFS Total Film Scanning
Mainscan with high resolution CCD chip (2,000 x 3,000 pixels)
Printer with digital print system (laser)
Scanner and Printer integrated in one housing
Paper Processor with AgfaPhoto-specific laser paper chemicals
Applies to netlab.2plus
Digital minilab to print images from digital sources (storage medium or network) and to save digital data on digital storage media or in a connected network
Printer with digital print system (laser)
Paper Processor with AgfaPhoto-specific laser paper chemicals
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Technical Data
AgfaPhoto 2005-05-01 / PN 04100_01 43
Print sizes Applies to d-lab.2
Minimum: 82 mm x 117 mm (3.25" x 4.6") on 82 mm / 3.25" paper width
Maximum: 305 mm x 457 mm (12" x 18") on 305 mm / 12" paper width
Applies to d-lab.2plus/netlab.2plus
Minimum: 82 mm x 89 mm (3.25" x 3.5") on 82 mm / 3.25" paper width
Maximum: 305 mm x 457 mm (12" x 18") on 305 mm / 12" paper width
Electrical requirements Connection specifications: 3W+N+PE 220/380V, 230/400V, 240/415V 50/60 Hz 3 x 16 A 3W+PE 200V, 210V, 220V, 230V, 240V 50/60 Hz 3 x 25 A 2W+PE 200V, 210V, 220V, 230V, 240V 50/60 Hz 1 x 32 A 1W+N+PE 200V, 210V, 220V, 230V, 240V 50/60 Hz 1 x 32 A
Film and negative / slide formats Applies only to d-lab.2/2plus
Film size Negative / slide formats
110 negatives Format 110 (color)
135 negatives Full frame, half frame, panorama (color and B/W)
135 slides mounted 5x5 cm and reversal film strips, color and black-and -white
IX240 negatives Classic, HighVision, Panorama (color and B/W)
120/220 negatives 6x4.5 cm, 6x6 cm, 6x7 cm, 6x8 cm, 6x9 cm
120/220 slides reversal film strips, color and black-and-white
Noise level 65 dB(A) standby 68 dB(A) printing
Main control Integrated main computer for the main control of the Minilab
Operating system Windows 2000, at least SP4
Touchscreen monitor (LCD or CRT) as user interface
Optional accessories Additional table for a larger working area
External label printer for price labels
Film carriers for different negative sizes and slides (only d-lab.2/2plus)
LCD touch-screen monitor
Options for further image processing functions
Space requirements for operation and service
Right 600 mm
Left 1,100 mm
Front 900 mm
Minimum distance to the wall: for operation 150 mm for service 600 mm
Technical Data d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
44 2005-05-01 / PN 04100_01 AgfaPhoto
Production capacity
Film format 135-24
Print format (mm)
Print format (inch)
Applies to d-lab.2
Prints/h (actual)
Orders (incl. index print)
Applies to d-lab.2plus
Prints/h (actual)
Orders (incl. index print)
89 x 127 102 x 152 127 x 178 203 x 305 305 x 457
3.5 x 5 4 x 6 5 x 7 8 x 12 12 x 18
1250 1200 1000 450
50 48 40 18
1.800 1.700 1.000 500 240
72 68 40 20 10
Paper width (mm)
Paper width (inch)
Applies to d-lab.2
Orders (incl. index print)
Applies to d-lab.2plus
Orders (incl. index print)
Film format IX240-25
89 102
3.5 4
32 30
40 35
Print format (mm)
Print format (inch)
Applies to d-lab.2
Prints/h (actual)
Applies to d-lab.2plus/ netlab.2plus
Prints/h (actual)
Digital images, file print from CD-ROM
89 x 127 102 x 152 114 x 152 127 x 178 203 x 305
3.5 x 5 4 x 6 4.5 x 6 5 x 7 8 x 12
1200 1100 – 900 450
1800 1700 1500 1000 500
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Technical Data
AgfaPhoto 2005-05-01 / PN 04100_01 45
Interfaces 1 GB Ethernet connection for data exchange and connection of an external workstation or a lab network
Modem
Label printer for price labels
Ambient conditions Ambient conditions for storage / transport: Temperature -50 °C to +60 °C Relative humidity 15% to 90%
Ambient conditions for operation: Room temperature +15 °C to +30 °C Relative humidity 15% to 85%
Maximum ambient light: Printer / Paper Processor 10,000 Lux Paper magazines 20,000 Lux
Chemical waste 250–375 ml waste per square meter of developed paper (1 m2 roughly corresponds to 65 prints of size 10x15 (4x6”)) The exact value depends on the set replenishment rate.
8.3 Main Computer
Operating system Windows 2000 OEM English, at least SP4
Mainboard
CPU
Applies to d-lab.2
GA-8GE800 PRO
Intel Pentium IV>2.5GHz
512 MB RAM
Motherboard Applies to d-lab.2plus and netlab.2plus
Dual Processor Motherboard
2x Intel Xeon 2.8 GHz
512 MB RAM
Image Processing Board To generate the digital images
Hard disk capacity ≥ 40 GByte
Graphics board Applies to d-lab.2
Onboard 82845G graphic controller
Applies to d-lab.2plus and netlab.2plus
Resolution: 1,024x768 pixels
Image recurrence frequency: >75Hz
Drives Applies to d-lab.2
Integrated drives for floppy disk, ZIP, CD-ROM/DVD, and memory cards (PCMCIA, Compact Flash, MicroDrive, SmartMedia, Memory Stick, SD/MMC memory card)
Applies to d-lab.2plus and netlab.2plus
Integrated FDD
External drive bay with CD-ROM, Zip, 5-fold PCMCIA drive (PCMCIA, Compact Flash, , MicroDrive, Smart Media, Sony Memory Stick, SD-memory board) connected to the main computer.
Technical Data d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
46 2005-05-01 / PN 04100_01 AgfaPhoto
Network connection 1 Applies to d-lab.2
1000 Mbit/s for external network connection
Applies to d-lab.2plus and netlab.2plus
1000 Mbit/s onboard for external network connection
Network Board 2 100 Mbit/s onboard for internal communication
Timer Board To control the switch-on and switch-off procedures
8.4 Prescanner / Scanner Applies only to d-lab.2/2plus
Resolution for negative size 135
Prescanner: approx. 500 pixels per color
Main scanner: approx. 6,000,000 pixels per color
Filter Optimized filter set for negative films
Optimized filter set for slides (optional)
Sensor type Monochrome CCD sensor 2k x 3k pixels
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Technical Data
AgfaPhoto 2005-05-01 / PN 04100_01 47
8.5 Printer
Laser recorder Exposure by a laser recorder
Paper transport speed 67 mm/s
Scanning width 305 mm / 12 inches
Resolution 400 dpi
Laser wavelength gas laser d-lab2: Type 8060/260 d-lab.2plus: Type 8060/261:
Blue 458 nm Green 514 nm Red 685 nm
Laser wavelength solid state laser d-lab2: type 8060/803, 8060/804, 8060/270, 8060/272 and 8060/157+8060/255 d-lab.2plus: type 8060/813, 8060/814, 8060/271, 8060/273 and 8060/158+8060/255 netlab.2plus: type 8060/505:
Blue 473 nm Green 532 nm Red 685 nm
Paper magazines 2 Paper magazines
Applies to d-lab.2 RH side: up to 305 mm / 12 inch paper width LH side: up to 210 mm / 8.25 inch paper width
Applies to d-lab.2plus and netlab.2plus RH and LH side: up to 305 mm / 12 inch paper width
Maximum paper length when using AgfaPhoto Splendix Paper: at a paper width up to 8.25 inch: 183 m for paper widths above 8.25 inches: 91.5 m
Maximum paper length when using AgfaPhoto Sensatis Paper: at a paper width up to 8.25 inch: 158 m for paper widths above 8.25 inches: 79.0 m
Paper transport Single sheet transport on one track, paper cut prior to the exposure
Sheet centering
Lane distributor to distribute the exposed paper on several tracks in the Paper Processor
Technical Data d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
48 2005-05-01 / PN 04100_01 AgfaPhoto
8.6 Paper Processor
Space requirement Length: 1,160 mm (incl. sorter 1,560 mm)
Width: 880 mm
Height: 1,450 mm (opened 1,860 mm)
Floor space for operation / service
Right: 600 mm
Distance to the wall: 150 mm (operation) / 600 mm (service)
Processor type Paper Processor for transport on several tracks (depending on the format)
Automatic replenishment system
Docking System for automatic replenisher tank filling
Astor system for reduction of chemical waste and water consumption
Automatic rinsing of the crossovers to avoid crystalline deposits
1 CD, 1 BX and 4 SB tanks
Integrated print sorter
6“ Sorter: Print formats up to 152 mm (6 inch) length are stacked in the sorter, bigger formats are not sorted and placed on the tray for large print formats.
10“ Sorter: Print formats up to 254 mm (10 inch) length are stacked in the sorter, bigger formats are not sorted and placed on the tray for large print formats.
Integrated Densitometer
Process specifications
Solution CD BX SB
Temperature 40 °C ± 0.3 38 °C ± 3 37 °C ± 3
Process time (in seconds) 33 33 total 69
Replenishment rates (ml / m2) (recommended values when using the AgfaPhoto Easy Paper Box 110 chemicals) Chemicals Water Chemicals Water Chemicals Water
Standard 41 10 68 0 41 159
increased Factor 1.4 14 Factor 1.4 0 Factor 1.4 223
maximum Factor 1.6 16 Factor 1.6 0 Factor 1.6 254
Tank – Automatic preparation of replenisher solutions
– Automatic mixing
– Automatic water replenishment
Tank capacity in liters CD BX SB
Processing tank 18.4 18.4 4 x 11.2
Replenisher tank 4.5 7.5 4.5
Effluent tank 10 10 7 (for Astor system)
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Technical Data
AgfaPhoto 2005-05-01 / PN 04100_01 49
Transport system – Two-lane transport by means of rollers
– Single sheet: minimum length 117 mm (Applies to d-lab.2) 89 mm (Applies to d-lab.2plus and netlab.2plus) maximum width 305 mm
– Sheet distribution: 2 lanes up to 203 mm (8 inch) paper width (up to 10x15 on alternating lanes) 1 lane up to 305 mm (12 inch) paper width
Paper transport speed approx. 34 mm/s
Dryer Warm air drying
8.7 Heat Emission
Input voltage (V) 200 210 220 230 240
Laser (machine with gas laser) 1) no value for machine with solid state laser1)
(kcal/h) 860 860 860 860 860
Solution heater Developer solution (CD)
(kcal/h) 251 277 304 332 362
Solution heater Bleachfix solution (BX)
(kcal/h) 251 277 304 332 362
Solution heater Stabilizer solution (SB1-4)
(kcal/h) 597 658 723 790 860
Dryer heater (kcal/h) 2,867 3,161 2,911 3,181 3,464
Total for machine with gas laser1) (kcal/h) 4,826 5,233 5,101 5,495 5,907
Total for machine with solid state laser1) (kcal/h) 3,966 4,373 4,241 4,635 5,047
1) Machines with gas laser: d-lab.2: type 8060/260
d-lab.2plus: type 8060/261 2) Machines with solid state laser: d-lab.2: type 8060/803, 8060/804, 8060/270, 8060/272 and
8060/157+8060/255
d-lab.2plus: type 8060/813, 8060/814, 8060/271, 8060/273 and 8060/158+8060/255
netlab.2plus: type 8060/505
8.8 Other Data
Operating conditions: see Operating conditions
Storage and Transport see Conditions for storage and transport
Index d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
50 2005-05-01 / PN 04100_01 AgfaPhoto
9 Index
1 1-phase operation 15
3 3-phase operation 15
A Accessories (optional 43
Additional parts / hardware / software, ordered 24
Air conditioning 11
Ambient conditions 45
Ambient light 13
B basic 25
C Checklist 17
accessories / hardware / software 21
consumables 21
customer 23
supply facilities 18
training 20
transport 17
Chemical waste 45
Chemicals
legal regulations 10
safety notes 10
Temperatures 48
Connection voltages and connection types 15
Consumables 37
Consumables, ordered 24
D Dimensions 41
Door opening
minimum size for transport 7
Drives 45
Dryer 49
E Easy paper Box 37
Electrical requirements 43
Emissions during operation 11
Exhaust 12
F Film and negative formats (only d-lab.2/2plus) 43
Floor
conditions 7
load capacity 7
G Graphics board 45
Grounding 16
I Image Processing Board 45
Installation date 24
Interfaces 45
L Laser recorder 47
M Machine
storage and transport 13
Machine dimensions packed
d-lab.2 2
d-lab.2plus 2
netlab.2plus 2
Machine dimensions unpacked
d-lab.2 3
d-lab.2plus 4
netlab.2plus 5
Main computer 45
Main control 43
Minilab
Machine versions 41
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation Index
AgfaPhoto 2005-05-01 / PN 04100_01 51
N Network board 46
Network connection 13
Noise level 13, 43
O Operating conditions 13
machine storage 13
transport 13
Operating system 45
Operation Manuals 37
Operation site 7
Options 43
Order numbers
consumables 37
Minilab
d-lab.2 basic 28
d-lab.2 select 26
d-lab.2/2plus Spezial-Version 70mm 34
d-lab.2plus basic 32
d-lab.2plus select 30
netlab.2plus basic 35
Operation Manuals 37
remote service 36
P Paper magazines
Technical data 47
Paper transport
Paper Processor 49
Printer 47
Paper, storage 8
Preinstallation measures 1
Print sizes 43
Process specifications 48
Production capacity 44
R Remote service 36
Replenishment rates
Default values 48
Required space
machine 8
operation, service 8
Room height 7
Room lighting 9
Room temperature 13
Room ventilation 11
S select 25
Slide formats (only d-lab.2/2plus) 43
Space requirement
operation, service 43
Storage (paper) 8
Storage and transport (machine) 13
Supply systems
contractors 23
T Tank capacity 48
Technical data
Complete system 41
electrical requirements 43
heat emission 49
Main computer 45
noise level 43
Paper magazines 47
Paper Processor 48
prescanner / scanner 46
Printer 47
Temperatures
Chemical solutions 48
Timer Board 46
Transport system 49
Type numbers 41
W Water connection 9
Weight empty
d-lab.2 6
d-lab.2plus 6
netlab.2plus 6
Weight filled
Index d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
52 2005-05-01 / PN 04100_01 AgfaPhoto
d-lab.2 6
d-lab.2plus 6
netlab.2plus 6
Weight packed
d-lab.2 2
d-lab.2plus 2
netlab.2plus 2
Weight unpacked
d-lab.2 6
d-lab.2plus 6
netlab.2plus 6
■