Booth Lighting www.ldpi-inc.com LDPI has lighting for all areas of your booth! Surface Mount Installation Recess Mount Installation Non-Classified Fixtures are designed and listed to be surface mounted inside an area where flammable gases/vapors are always present.* Fixtures are designed and listed to be recess mounted into the booth walls or ceiling and are considered to be integral to the wall or ceiling after installation.* Class 1, Division 1 Paint/Spray Listed Explosion-Proof Class 1, Division 2 Paint/Spray Listed Hazardous 1 2 3 Paint / Powder Booths Mix Rooms Paint / Powder Booths Paint Storage Blast Booths Fixtures that are designed and listed to be mounted outside a classified area where flammable gases or vapors are present. Fixtures are separated from the spray area by a glass panel and meet the requirements of that area.* Paint Booths (Behind Glass) Prep Areas *Always reference NFPA 33 & NEC codes and standards for correct compliance

Upload: others

Post on 22-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: D-1333 Booth Flyer - LDPI Inc · booth walls or ceiling and are considered to be integral to the wall or ceiling after installation.* Class 1, Division 1 Paint/Spray Listed Explosion-Proof

BoothLighting

www.ldpi-inc.com

LDPI has lighting for all areas of your booth!

Surface MountInstallation

Recess MountInstallation

Non-Classified

Fixtures are designed and listed to be surface mounted inside an area where flammable gases/vapors are always present.*

Fixtures are designed and listed to be recess mounted into the booth walls or ceiling and are considered to be integral to the wall or ceiling after installation.*

Class 1, Division 1Paint/Spray ListedExplosion-Proof

Class 1, Division 2Paint/Spray ListedHazardous

1

2

3

Paint / Powder BoothsMix Rooms

••

Paint / Powder BoothsPaint StorageBlast Booths

•••

Fixtures that are designed and listed to be mounted outside a classified area where flammable gases or vapors are present. Fixtures are separated from the spray area by a glass panel and meet the requirements of that area.*

Paint Booths (Behind Glass)Prep Areas

••

*Always reference NFPA 33 & NEC codes and standards for correct compliance

Page 2: D-1333 Booth Flyer - LDPI Inc · booth walls or ceiling and are considered to be integral to the wall or ceiling after installation.* Class 1, Division 1 Paint/Spray Listed Explosion-Proof

Non-Classified / Listed for use outside a paint booth behind a glass panel

Hazardous / Class I, Div. 2

Explosion-Proof / Class I, Div. 1

LDPI, Inc.4404 Anderson DriveEau Claire, WI 54703

(800)[email protected]

Bright Ideas. Innovative Solutions.

www.ldpi-inc.com

ARSHAZARDOUS

LIGHTING SOLUTIONS

Durable lighting for paint booths, paint storage and mix rooms

3

2

1

LEXS3,800 to 10,260Lm40W & 80W

LE5512,474 to 14,328Lm24W to 128W

380LED3,820 to 9,880Lm35W to 98W

LEXF1 (coming soon)3,000 to 9,000Lm20W, 40W, 50W & 60W

LE4848,270 & 9,070Lm75W

LE4826,985 to 21,075Lm58W to 218WRear Access

LE4816,985 to 21,075Lm58W to 218WFront Access

390440-LED5,470, 6,150 & 8,850Lm64W, 70W & 97W

LE1806,640 to 11,400Lm53W & 75W

LE155H3,140 to 51,710Lm28W to 413W