custom signs & printing - icc compliance center · custom signs & printing usa 888.442.9628...
TRANSCRIPT
Custom Signs & Printing
USA 888.442.9628 • CAN 888.977.4834 V0414EC www.thecompliancecenter.com
Advertising and branding are an important part of any successful business. Get your message across in a clear and concise
manner. Stand out from the competition with custom signage and printing from ICC Compliance Center. We have a team of
graphic artists and in-house printing capabilities to deliver what you need.
Vehicle Lettering Window & Door Lettering
HAZARD CLASS
As per classof residue
LimitedQuantity
1.1Explosives
1.2Explosives
1.3Explosives
1.4Explosives
1.4SExplosives
1.5Explosives
1.6Explosives
2.1Flammable
Gases
2.2Non-flammableNon-toxic Gases
2.2(5.1)Oxidizing Gases
2.3Toxic Gases
2.3(8)AnhydrousAmmonia,in large means of
containment
N/A
N/A
For more than 10 drums
Plus the words: Anhydrous AmmoniaInhalation Hazard
N/A
N/A
For more than 1,000 kg, unless UN0301, which must be placarded for more than 75 kg.
LABELS REQUIREDPLACARDS
1
1.2* 1
1.2*
1
1.3* 1
1.3*
1
1.1* 1
1.1*
2 2
or
3Flammable
Liquids
4.1Flammable
Solids
5.1Oxidizing
Substances
5.2Organic
Peroxides
6.1Toxic
Substances
7Radioactive
Materials
8Corrosives
9Miscellaneous
Products, Substances or
Organisms
When Dangerous Goods are placed in a large means of containment (capacity exceeding 450 L), such as a vehicle or freight container, four (4) placards must be displayed if the dangerous goods meet ANY of the following conditions:
1) In a quantity or concentration that requires an emergency response assistance plan (ERAP)2) In any quantity where a class 7 category III label is required3) Liquid or gas in direct contact with the large means of containment (Bulk)4) Total gross mass of dangerous goods exceed 500 kg
6.2Infectious
Substances Category A
6.2Infectious
Substances Category B
4.2Substance Liable to Spontaneous
Combustion
4.3Water Reactive
Substances
3 3
4 4
6 6
6
6
7
7
RADIOACTIVE IIICONTENTS......................................CONTENUACTIVITY.........................................ACTIVITÉ
INDICE DE TRANSPORT INDEX
7
FISSILE
CRITICALITYSAFETY INDEX
6
INFECTIOUS-INFECTIEUXIN CASE OF DAMAGE EN CAS DE DOMMAGE
OR LEAKAGE OU DE FUITE COMMUNIQUERIMMEDIATELY NOTIFY IMMÉDIATEMENT
LOCAL AVEC LES AUTORITESAUTHORITIES LOCALES
OR OUCANUTEC
613-996-6666
6
INFECTIOUS-INFECTIEUXIN CASE OF DAMAGE EN CAS DE DOMMAGE
OR LEAKAGE OU DE FUITE COMMUNIQUERIMMEDIATELY NOTIFY IMMÉDIATEMENT
LOCAL AVEC LES AUTORITESAUTHORITIES LOCALES
OR OUCANUTEC
613-996-6666
8 8
9 9
HAZARD CLASS LABELS REQUIRED
PLACARDS
*
1.4
1*
1.4
1*
1.5
1*
1.5
1*
1.6
1*
1.6
1*
2 2
2 2
2 2
2
4 4
5.1
5.2
5.1
5.25.2 5.2
7
RADIOACTIVE ICONTENTS......................................CONTENUACTIVITY.........................................ACTIVITÉ
7
RADIOACTIVE IICONTENTS......................................CONTENUACTIVITY.........................................ACTIVITÉ
INDICE DE TRANSPORT INDEX
4 4
+
PLACARD OPTIONS
CLASS 1 - EXPLOSIVES CLASS 2 - GASES
PLACARD DESCRIPTIONS
DISPLAY OF UN NUMBERS
OTHER SAFETY MARKS
SUBSIDIARY PLACARDS DANGER PLACARDS ADDITIONAL US PLACARD REQUIREMENTS
- Must placard for any amount of Class 1.1, 1.2, 1.3 or 1.5 not subject to special provision 85 or 86, that exceeds 10 kg net explosives quantity.- Must placard for any amount of Class 1.1, 1.2, 1.3 or 1.5 subject to special provision 85 or 86, if the number of articles exceeds 1,000. - Mixed load of EXPLOSIVES use placards with the lowest division number except when:
The four-digit UN number must be displayed on or next to the primary class placards in the following cases:
In addition to the primary class placards, subsidiary placards are required for goods that require an ERAP and have the following:
The Danger placard can replace two or more separate primary class placards, except for:
a) Goods requiring an ERAPb) Class 1c) Class 7
LARGE MEANS OF CONTAINMENT (BULK) (GREATER THAN 450 L CAPACITY)
OTHER MEANS OF CONTAINMENT
For mixed loads of gases, use:• Placard that corresponds to the primary class – OR –• DANGER placard and the primary class placard that corresponds to the most dangerous gas in this following order:
IBCs, portable tanks, cargo tanks, tank cars and other bulk packagings that are in direct contact with a liquid or a gas.
- Dangerous goods that require an ERAP- Dangerous goods with the same UN number in a quantity greater than 4000 kg o§ered for transport by one consignor (optional)
Class 1.2 is transported with Class 1.5, use Class 1.1 placards. Class 1.5 and Class 1.4 are transported together, use Class 1.5 placards.
2
2
2
2
The Oxidizing Gas placard must be displayed for the following UN numbers:
UN1072 OXYGEN, COMPRESSED UN1073 OXYGEN, REFRIGERATED LIQUID UN3156 COMPRESSED GAS, OXIDIZING, N.O.S. UN3157 LIQUEFIED GAS, OXIDIZING, N.O.S. 2
Note: A UN Number is not required to be displayed for Class 1 Explosives.
Subsidiary class (1) Subsidiary class (4.3) Subsidiary class (6.1), PG I, Inhalation toxicity
UN2977 or UN2978 Radioactive Material, Uranium Hexafluoride
In addition to the Canadian placards, Poison Gas (Class 2.3) or Poison Inhalation Hazard (Class 6.1) placards are required on dangerous goods that meet the definition of “materials toxic by inhalation” in 49 CFR when transported into the United States.
The Marine Pollutant Mark is required for dangerous goods that are marine pollutants transported by ship, (other than roll-on roll-o§ ship and short run ferry) except if they:
- Do not contain Class 1 (other than 1.4), 5.2, 6.1 or 7; AND
i) Are in a large means of containment with a capacity less than or equal to 500 kg
AND are transported between two points in Canada; - OR -
ii) Are in a small means of containment with quantities less than or equal to 500 mL or 500 g for severe marine pollutants or less than or equal to 5 L or 5 kg for marine pollutants.
MARINE POLLUTANT
The Elevated Temperature Sign is required in addition to the primary class placard for the following products:
UN3256 ELEVATED TEMPERATURE LIQUID, FLAMMABLE, N.O.S. UN3257 ELEVATED TEMPERATURE LIQUID, N.O.S. UN3258 ELEVATED TEMPERATURE SOLID, N.O.S.
The Fumigation Sign is required at each entryway of a large means of containment that has been fumigated.
WWW.THECOMPLIANCECENTER.COM © 2013 COMPLIANCE CENTER V0913 | PART NUMBER: PO-MS26E
1
1.1*
Placards on both sides and on both ends
Placards on both sides and on both ends
Placards on both sides and on both ends
Placards on both sides and on both ends
Wide Format & Poster Printing Banners & Banner Stands
Sandwich Boards Real Estate Signage
WE ALSO OFFER SIGNS ON ALUMINUM, CORRUGATED PLASTIC,MAGNETIC, AND PLYWOOD