WH W D WH W D AREA CALCULATIONS - ENITRE HOUSE HEATED & COOLED OF: FIRST FLOOR LIVING: GARAGE: FRONT PORCH: BACK PORCH: TOTAL OF: HEATED & COOLED OB: 2934 SF 2934 SF 628 SF 00 SF 224 SF 3786 SF 3046 SF FLOOR PLAN NOTES: 1. THE CONTRACTOR AND SUBCONTRACTOR(S) SHALL THOROUGHLY FAMILIARIZE THEMSELVES WITH THE CONTRACT DOCUMENTS AND SHALL IMMEDIATELY REPORT ALL QUESTIONABLE CONDITIONS TO THE DESIGNER BEFORE STARTING THE WORK. 2. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 3. COORDINATE ALL PORTIONS OF THE WORK. 4. DIMENSIONS SHOWN ON FLOOR PLAN ARE STUD DIMENSIONS - FROM FACE OF STUD TO FACE OF STUDE UNLESS OTHERWISE NOTED. 5. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE WINDOW FOR EMERGENCY EGRESS. ALL EGRESS WINDOWS TO MEET LOCAL CODES AND REGULATIONS. 6. PROVIDE SAFETY GLASS IN ALL THE FOLLOWING LOCATIONS: ANY BATHROOM WINDOWS WHERE THE BOTTOM OF THE GLAZING IS LESS THAN 60" ABOVE THE F.F.E., ALL STAIR CASES, ALL WINDOWS WHERE THE BOTTOM OF THE GLAZING IS LESS THAN 12" ABOVE THE F.F.E., AND ALL EXTERIOR DOORS WITH GLAZING. 7. WINDOWS TO BE SCREWED AND INSTALLED TO MANUFACTURER'S INSTALLATION INSTRUCTIONS. 8. ALL BOTTOM PLATES, INTERIOR AND EXTERIOR, TO BE TREATED LUMBER. 9. WALLS LESS THAN 5' TO PROPERTY LINE ARE REQUIRED TO HAVE A ONE HOUR FIRE RATING. 10. BATHROOM EXHAUST FANS SHOULD BE TERMINATED AT LEAST 10" ABOVE INSULATION OR VENTED THROUGH ROOF IF SPRAY FOAM IS USED. 11. SHOWER WALLS MUST USE CEMENT BACKER BOARD WHEN TILE IS INSTALLED. A 4' - 0" L= B 1' - 8" L= BRACED WALL PANEL ALTERNATE BRACED WALL PANEL LAMINATED BEAM SEE WALL BRACING DETAILS ON SHEET A3 WALL PANEL BRACING 9' x7' OH DR 9' x7' OH DR (2) 2068 3060 SH GARAGE 15' - 0" X 24' - 0" 9' FLAT CEILING GARAGE 15' - 0" X 24' - 0" 9' FLAT CEILING GREAT ROOM 15' - 2" X 21' - 0" 9' CLG LVP FLOOR BDRM #2 11' - 10" X 9' - 5" 9' FLAT CEILING CARPET BATH 9' CLG LVP BDRM #3 12' - 0" X 10' - 4" VAULTED CLG CARPET MASTER BEDRM 12' - 0" X 13' - 2" VAULTED CEILING CARPET WIC BATH 9' CEILING LVP FLOOR KITCHEN & DINING AREA 13' - 10" X 21' - 0" CATHEDRAL CEILING LVP FLOOR ATTIC STAIR LOCATION TBD ON SITE ATTIC STAIR LOCATION TBD ON SITE 3060 SH 2860 SH 2860 SH 3080 BN DR 2868 3050 3050 3068 2468 FRIDGE LAMINATED BEAM LAMINATED BEAM 1HR FIRE WALL, RE: 2/A1 and 3/A1 WIC 2068 2850 SH DW SEAT SEAT GREAT ROOM 15' - 2" X 21' - 0" 9' CLG LVP FLOOR KITCHEN & DINING AREA 13' - 10" X 21' - 0" CATHEDRAL CLG LVP FLOOR MASTER BEDRM 12' - 0" X 13' - 2" VAULTED CLG CARPET BATH 9' CLG LVP FLOOR WIC WIC 3068 FRIDGE 2868 3068 3080 BN DR PANTRY 2868 (2) 2068 2868 2868 2868 2850 SH 3050 3050 3068 2850 SH PANTRY 2468 3068 3068 2868 5FT FIBERGLASS 2868 2868 2868 (2) 2068 (2) 2068 BEDRM #2 11' - 10" X 9' - 5" 9' CLG CARPET BEDRM #3 12' - 0" X 10' - 4" CATHEDRAL CLG CARPET BATH 9' CLG LVP 3'X7' C/O 3'X7' C/O 2070 C/O 2070 C/O 2070 C/O 2070 C/O 5FT FIBERGLASS 2850 SH BACK PORCH 9' CLG BACK PORCH 9' CLG 0' - 3 1/2" 3' - 5" 7' - 5" 3' - 5 1/8" 0' - 7 5/8" 3' - 5" 7' - 4 1/2" 3' - 4 1/2" 29' - 4 1/4" 13' - 5 1/2" 4' - 5 1/2" 6' - 3 1/2" 0' - 3 1/2" 17' - 0 1/2" 10' - 9 1/2" 2' - 7" 9' - 9 1/2" 3' - 6" 24' - 9" 24' - 2 1/2" 0' - 3 1/2" 75' - 11" 3' - 8 1/2" 12' - 3 1/2" 14' - 0 1/4" 13' - 3 1/2" 12' - 4" 3' - 8 1/2" 0' - 3 1/2" 59' - 7 3/4" 6' - 3 1/2" 4' - 5 1/2" 13' - 5 1/2" 24' - 9" 3' - 6" 9' - 9 1/2" 2' - 7" 10' - 9 1/2" 0' - 3 1/2" 0' - 3 1/2" 15' - 1 1/2" 29' - 0 3/4" 15' - 2" 7' - 11 1/2" 1' - 10" 2' - 3" 22' - 6" 3' - 3 1/2" 3' - 8" 5' - 7 1/2" 4' - 5" 2' - 10" 10' - 7 1/2" 2' - 6 1/2" 10' - 11" 4' - 1 1/2" 5' - 8" 3' - 8" 3' - 7" 5' - 0 1/2" 4' - 1 1/2" 3' - 1 1/2" 3' - 6 1/2" 3' - 2" 4' - 1 1/2" 5' - 1 1/8" 3' - 6 1/2" 5' - 3 1/2" 4' - 3 1/2" 7' - 10 1/2" 3' - 10" 3' - 4" 10' - 0 5/8" 8' - 9 1/2" 7' - 9" 6' - 0" 6' - 2" 3' - 10" 2' - 3 1/2" 5' - 2 11/16" 21' - 4" A 4 ' - 0 " L = A 4' - 0" L= A 4 ' - 0 " L = A 4 ' - 0 " L = A 4' - 0" L= A 4 ' - 0 " L = A 4 ' - 0 " L = A 4 ' - 0 " L = A 4 ' - 0 " L = A 4 ' - 0 " L = A 4' - 0" L= A 4' - 0" L= A 4' - 0" L= A 4 ' - 0 " L = A 4 ' - 0 " L = A 4 ' - 0 " L = A 4 ' - 0 " L = A 4 ' - 0 " L = A 4' - 0" L= B 1' - 8" L= B 1' - 8" L= B 1' - 8" L= B 1' - 8" L= 3080 BN DR 3' - 10" 3080 BN DR 3' - 1" 2068 3' - 1" AREA CALCULATIONS - EACH SIDE HEATED & COOLED OF: FIRST FLOOR LIVING: GARAGE: FRONT PORCH: BACK PORCH: TOTAL OF: HEATED & COOLED OB: 1467 SF 1467 SF 314 SF 00 SF 112 SF 1893 SF 1523 SF 1/2" GYP. BOARD 2X4 STUD @16" O.C., STAGGER STUDS R22 INSULATION TO FILL CAVITY 1/2" GYP. BOARD R22 INSULATION TO FILL CAVITY NO PENETRATIONS THRU FIRE WALL ALLOWED *FIRE WALL SHOULD RUN VERTICALLY FROM f.f.E. UP TO ROOF DECK 0' - 0 5/8" 0' - 3 1/2" 0' - 0 5/8" 5/8" TYPE X GYP. BD. EACH SIDE 1/2" GYP. BOARD R22 INSULATION TO FILL CAVITY 1/2" GYP. BOARD R22 INSULATION TO FILL CAVITY NO PENETRATIONS THRU FIRE WALL ALLOWED 0' - 0 5/8" 0' - 3 1/2" 0' - 0 5/8" 5/8" TYPE X GYP. BD. EACH SIDE 5/8" TYPE X GYP. BD. EACH SIDE UP TO ROOF DECK NO PENETRATIONS THRU FIRE WALL ALLOWED CEILING JOIST A T T S X E T E F O S A R E G I S T E R E D A R C H I T E C T W A H S A R B R A A S D 5 5 8 2 M. 2 DO NOT REPRODUCE WITHOUT WRITTEN PERMISSION FROM CLEARVIEW CUSTOM HOMES, LLC. PO BOX 64756 LUBBOCK TX 79464 806.777.0421 DATE: DRAWINGS PREPARED BY: [email protected] MAILING ADDRESS: PO BOX 64756 LUBBOCK, TX 79464 SARA BRADSHAW, AIA OFFICE ADDRESS: 10507 QUAKER AVE. SUITE 101 LUBBOCK, TX 79423 PHONE: 806.445.1255 A1 FLOOR PLAN 07-10-17 SPEC DUPLEX STONEBRIDGE - LOT #124 2026 102ND STREET LUBBOCK, TX SIGNED:07-10-17 DUPLEX 1/4" = 1'-0" 1 FLOOR PLAN 1" = 1'-0" 2 DUPLEX 1HR FIRE WALL - PLAN DETAIL 1" = 1'-0" 3 DUPLEX 1HR FIRE WALL - SECTION DETAIL No. Revision Date 1 Revision 1 Date 1

Upload: others

Post on 21-Aug-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: C:UsersSaraDropbox01-Residential Projects 6 102ndStonebridge - …aarondanielhomesofwesttexas.townsquareinteractive.com/... · 2017. 12. 18. · master bedrm 12' - 0" x 13' - 2" vaulted

WH

WD WHW

D

AREA CALCULATIONS -ENITRE HOUSE

HEATED & COOLED OF:

FIRST FLOOR LIVING:GARAGE:

FRONT PORCH:BACK PORCH:

TOTAL OF:

HEATED & COOLED OB:

2934 SF

2934 SF628 SF00 SF224 SF

3786 SF

3046 SF

FLOOR PLAN NOTES:

1. THE CONTRACTOR AND SUBCONTRACTOR(S) SHALL THOROUGHLY FAMILIARIZE THEMSELVES WITH THE CONTRACT DOCUMENTS AND SHALL IMMEDIATELY REPORT ALL QUESTIONABLE CONDITIONS TO THE DESIGNER BEFORE STARTING THE WORK.

2. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.

3. COORDINATE ALL PORTIONS OF THE WORK.4. DIMENSIONS SHOWN ON FLOOR PLAN ARE STUD DIMENSIONS - FROM FACE

OF STUD TO FACE OF STUDE UNLESS OTHERWISE NOTED.5. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE WINDOW

FOR EMERGENCY EGRESS. ALL EGRESS WINDOWS TO MEET LOCAL CODES AND REGULATIONS.

6. PROVIDE SAFETY GLASS IN ALL THE FOLLOWING LOCATIONS: ANY BATHROOM WINDOWS WHERE THE BOTTOM OF THE GLAZING IS LESS THAN 60" ABOVE THE F.F.E., ALL STAIR CASES, ALL WINDOWS WHERE THE BOTTOM OF THE GLAZING IS LESS THAN 12" ABOVE THE F.F.E., AND ALL EXTERIOR DOORS WITH GLAZING.

7. WINDOWS TO BE SCREWED AND INSTALLED TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.

8. ALL BOTTOM PLATES, INTERIOR AND EXTERIOR, TO BE TREATED LUMBER.9. WALLS LESS THAN 5' TO PROPERTY LINE ARE REQUIRED TO HAVE A ONE

HOUR FIRE RATING. 10. BATHROOM EXHAUST FANS SHOULD BE TERMINATED AT LEAST 10" ABOVE

INSULATION OR VENTED THROUGH ROOF IF SPRAY FOAM IS USED. 11. SHOWER WALLS MUST USE CEMENT BACKER BOARD WHEN TILE IS

INSTALLED.

A4' - 0"L=

B1' - 8"L=

BRACED WALL PANEL

ALTERNATE BRACED WALL PANEL

LAMINATED BEAM

SEE WALL BRACING DETAILS ON SHEET A3

WALL PANEL BRACING

9' x7' OH DR

9' x7' OH DR

(2) 2068

3060 SH

GARAGE15' - 0" X 24' - 0"9' FLAT CEILING GARAGE

15' - 0" X 24' - 0"9' FLAT CEILING

GREAT ROOM15' - 2" X 21' - 0"

9' CLGLVP FLOOR

BDRM #211' - 10" X 9' - 5"9' FLAT CEILING

CARPET

BATH9' CLGLVP

BDRM #312' - 0" X 10' - 4"VAULTED CLG

CARPET

MASTER BEDRM12' - 0" X 13' - 2"VAULTED CEILING

CARPET

WIC

BATH9' CEILING

LVP FLOOR

KITCHEN & DININGAREA

13' - 10" X 21' - 0"CATHEDRAL CEILING

LVP FLOOR

ATTIC STAIR LOCATION TBD ON SITE

ATTIC STAIR LOCATION TBD ON SITE

3060 SH 2860 SH 2860 SH

3080 BN DR

2868

3050 3050

3068

2468

FR

IDG

E

LAMINATED BEAM

LAMINATED BEAM

1HR FIRE WALL, RE: 2/A1 and 3/A1

WIC

20

68

2850

SH

DW

SEATSEAT

GREAT ROOM15' - 2" X 21' - 0"

9' CLGLVP FLOOR

KITCHEN & DININGAREA

13' - 10" X 21' - 0"CATHEDRAL CLG

LVP FLOOR

MASTER BEDRM12' - 0" X 13' - 2"VAULTED CLG

CARPET

BATH9' CLG

LVP FLOOR

WIC WIC

30

68

FR

IDG

E

2868

3068

3080 BN DR

PANTR

Y

2868

(2) 2068

2868

2868

2868

2850

SH

3050 3050

3068

2850

SH

PANTR

Y

24683068

30

68

2868

5FT

FIB

ER

GLASS

2868

2868

2868

(2) 2068

(2) 2068

BEDRM #211' - 10" X 9' - 5"

9' CLGCARPET

BEDRM #312' - 0" X 10' - 4"CATHEDRAL CLG

CARPET

BATH9' CLGLVP

3'X7' C/O 3'X7' C/O

20

70

C/O

20

70

C/O

20

70

C/O

20

70

C/O

5FT

FIB

ER

GLASS

2850

SH

BACK PORCH

9' CLGBACK PORCH

9' CLG

0' - 3 1/2"

3' - 5" 7' - 5" 3' - 5 1/8"

0' - 7 5/8"

3' - 5" 7' - 4 1/2" 3' - 4 1/2"

29' - 4 1/4"

13' -

5 1

/2"

4' -

5 1

/2"

6' -

3 1

/2"

0' -

3 1

/2"

17' - 0 1/2"

10' -

9 1

/2"

2' -

7"

9' -

9 1

/2"

3' -

6"

24' -

9"

24' -

2 1

/2"

0' -

3 1

/2"

75' -

11"

3' - 8 1/2" 12' - 3 1/2" 14' - 0 1/4" 13' - 3 1/2" 12' - 4" 3' - 8 1/2"0' - 3 1/2"

59' - 7 3/4"

6' -

3 1

/2"

4' -

5 1

/2"

13' -

5 1

/2"

24' -

9"

3' -

6"

9' -

9 1

/2"

2' -

7"

10' -

9 1

/2"

0' -

3 1

/2"

0' - 3 1/2" 15' - 1 1/2" 29' - 0 3/4" 15' - 2"

7' -

11 1

/2"

1' -

10

"2' -

3"

22' -

6"

3' - 3 1/2" 3' - 8" 5' - 7 1/2" 4' - 5"

2' -

10"

10' -

7 1

/2"

2' -

6 1

/2"

10' -

11"

4' - 1 1/2" 5' - 8" 3' - 8" 3' - 7"

5' - 0 1/2" 4' - 1 1/2" 3' - 1 1/2"

3' - 6 1/2"

3' - 2" 4' - 1 1/2" 5' - 1 1/8"

3' - 6 1/2"

5' -

3 1

/2"

4' - 3 1/2" 7' - 10 1/2" 3' - 10" 3' - 4" 10' - 0 5/8"

8' -

9 1

/2"

7' -

9"

6' - 0" 6' - 2" 3' - 10"

2' - 3 1/2"

5' -

2 1

1/16

"21' -

4"

A4' - 0"

L=

A4' - 0" L=

A4' - 0"

L=

A4'

- 0"

L=

A4' - 0" L=

A4'

- 0"

L=A

4' -

0"L=

A4'

- 0"

L=

A4'

- 0"

L=

A4'

- 0"

L=

A4' - 0"L=

A4' - 0"L=

A4' - 0"L=

A4' - 0"

L=

A4' - 0"

L=

A4' - 0"

L=A

4' - 0"L=

A4' - 0"

L=

A4' - 0" L=

B1' - 8" L=

B1' - 8" L= B1' - 8" L=

B1' - 8" L=

3080 BN DR

3' - 10"

3080 BN DR

3' - 1"

20

68

3' - 1"

AREA CALCULATIONS -EACH SIDE

HEATED & COOLED OF:

FIRST FLOOR LIVING:GARAGE:

FRONT PORCH:BACK PORCH:

TOTAL OF:

HEATED & COOLED OB:

1467 SF

1467 SF314 SF00 SF112 SF

1893 SF

1523 SF

1/2" GYP. BOARD

2X4 STUD @16" O.C., STAGGER STUDSR22 INSULATION TO FILL CAVITY

1/2" GYP. BOARD

R22 INSULATION TO FILL CAVITY

NO PENETRATIONS THRU FIRE WALL ALLOWED

*FIRE WALL SHOULD RUN VERTICALLY FROM f.f.E. UP TO ROOF DECK

0' - 0 5/8"

0' - 3 1/2"

0' - 0 5/8"

5/8" TYPE X GYP. BD. EACH SIDE

1/2" GYP. BOARD

R22 INSULATION TO FILL CAVITY

1/2" GYP. BOARD

R22 INSULATION TO FILL CAVITY

NO PENETRATIONS THRU FIRE WALL ALLOWED

0' - 0 5/8"

0' - 3 1/2"

0' - 0 5/8"

5/8" TYPE X GYP. BD. EACH SIDE

5/8" TYPE X GYP. BD. EACH SIDE UP TO ROOF DECK

NO PENETRATIONS THRU FIRE WALL ALLOWED

CEILING JOIST

AT

TS

XETE FO

SA

REG

IS

TERED ARCHITEC

TWAHS

ARB

RAAS

D

55 82

M.

2

DO NOT REPRODUCE WITHOUT WRITTEN PERMISSION FROM

CLEARVIEW CUSTOM HOMES, LLC.PO BOX 64756 LUBBOCK TX 79464

806.777.0421

DATE:

DR

AW

ING

S P

RE

PA

RE

D B

Y:

SA

RA

@C

LE

AR

VIE

WC

US

TO

MH

OM

ES

.CO

M

MA

ILIN

G A

DD

RE

SS

:P

O B

OX

64

75

6

LU

BB

OC

K,

TX

79

46

4

SA

RA

BR

AD

SH

AW

, AIA

OF

FIC

E A

DD

RE

SS

:1

05

07

QU

AK

ER

AV

E.

SU

ITE

10

1L

UB

BO

CK

, T

X 7

94

23

PH

ON

E:

80

6.4

45

.12

55

A1FLOOR PLAN

07-10-17

SP

EC

DU

PLE

XS

TO

NE

BR

IDG

E -

LO

T #

124

2026

102

ND

ST

RE

ET

LUB

BO

CK

, TX

SIGNED:07-10-17

DUPLEX

1/4" = 1'-0"1

FLOOR PLAN

1" = 1'-0"2

DUPLEX 1HR FIRE WALL - PLANDETAIL

1" = 1'-0"3

DUPLEX 1HR FIRE WALL - SECTIONDETAIL

No. Revision Date1 Revision 1 Date 1

Page 2: C:UsersSaraDropbox01-Residential Projects 6 102ndStonebridge - …aarondanielhomesofwesttexas.townsquareinteractive.com/... · 2017. 12. 18. · master bedrm 12' - 0" x 13' - 2" vaulted

F.F.E.0' - 0"

10' PLATE HIEGHT10' - 0"

9' PLATE HIEGHT9' - 0"

2860 SH 2860 SH3060 SH3060 SH 9' x7' OH DR 9' x7' OH DR

COMPOSITE SHINGLE

BRICK

BRICK

6"

12"

CEDAR HEADER

CEDAR HEADER

8"

12"

8"

12"

6"

12"6"

12"

3068 2850 SH2850 SH

6"

12"

30682850 SH 2850 SH

6"

12"

COMPOSITE SHINGLE

BRICK

306830503050 3050 30503068

COMPOSITE SHINGLE

BRICK

6"

12"

AT

TS

XETE FO

SA

REG

IS

TERED ARCHITEC

TWAHS

ARB

RAAS

D

55 82

M.

2

DO NOT REPRODUCE WITHOUT WRITTEN PERMISSION FROM

CLEARVIEW CUSTOM HOMES, LLC.PO BOX 64756 LUBBOCK TX 79464

806.777.0421

DATE:

DR

AW

ING

S P

RE

PA

RE

D B

Y:

SA

RA

@C

LE

AR

VIE

WC

US

TO

MH

OM

ES

.CO

M

MA

ILIN

G A

DD

RE

SS

:P

O B

OX

64

75

6

LU

BB

OC

K,

TX

79

46

4

SA

RA

BR

AD

SH

AW

, AIA

OF

FIC

E A

DD

RE

SS

:1

05

07

QU

AK

ER

AV

E.

SU

ITE

10

1L

UB

BO

CK

, T

X 7

94

23

PH

ON

E:

80

6.4

45

.12

55

A2ELEVATIONS

07-10-17

SP

EC

DU

PLE

XS

TO

NE

BR

IDG

E -

LO

T #

124

2026

102

ND

ST

RE

ET

LUB

BO

CK

, TX

SIGNED:07-10-17

DUPLEX

1/4" = 1'-0"1

FRONT - NORTH

3/16" = 1'-0"2

LEFT - EAST

3/16" = 1'-0"3

RIGHT - WEST

3/16" = 1'-0"4

BACK - SOUTH

No. Revision Date

Page 3: C:UsersSaraDropbox01-Residential Projects 6 102ndStonebridge - …aarondanielhomesofwesttexas.townsquareinteractive.com/... · 2017. 12. 18. · master bedrm 12' - 0" x 13' - 2" vaulted

CRICKET DIMENSIONS

ROOF SLOPE H

12 - 12 1/2 OF W

8 - 12 1/3 OF W

6 - 12 1/4 OF W

4 - 12 1/6 OF W

3 - 12 1/8 OF W

H

ROOF LINE

1" M

IN. AIR

SPAC

E

W

FLUE LINERPLAN VIEW

ELEVATION VIEW

CLR

.0

' -

2"

MIN.

1' - 4"

INTERIOR LOAD BEARING WALL

MIN

.

1' -

0"

CONCRETE SLAB-ON-GRADE PER CITY OF LUBBOCK REQUIREMENTS

#3 TIES @ 32" O.C.

COMPACTED FILL

6 MIL VAPOR RETARDER, OVERLAP 6" AND TAPE PER MFR. RECOMENDATION

2-#4 BARS CONT. SET ON REBAR CHAIRS

UNIFORMED CONTINUOUS FOOTING

CLR.0' - 3"

MIN.

1' - 4"

FOR ONE AND TWO-STORY CONSTRUCTION

2X FRAMING AS REQUIRED

GARAGE DOOR OPENING

SLO

PE

MIN.

1' - 0"

FACE BRICK

CONCRETE CURB

FOOTING SHALL BE CONTINUOUS AT GARAGE DOOR OPENING

9

A3

Sim

0' - 5 1/2"

MIN

.

1' -

0"

MIN.

1' - 4"

STUD LINE

CLR

.0

' -

3"

CONTINUOUS FOOTING BEYOND (REINFORCEING CONTINUOUS THROUGH SPREAD FOOTING)

MIN

.

2' -

0"

4-#4 BARS EACH WAY

COMPACTED FILL

(X VARIES)

2' - 6"

0' -

4"

0' - 2"

CHAMFER OR TOOLED EDGE

EXPANSION JOINT FILLER MATERIAL WITH CAULKING

#3 U-SHAPED DOWELS @ 32" O.C.

SLOPE

6"

6"#3 BAR CONT.

CLR

.0

' -

2"

0' - 5 1/2"

MIN

.

1' -

0"

MIN.

1' - 4"

MIN.

0' - 8"

8" MIN.

INSULATION

STUD LINE

FACE BRICK WITH BRICK TIES @ 24" O.C. MAX EACH WAY (BRICK TIES TO SUPPORT NO MORE THAN 2.67 SQUARE FEET OF BRICK AREA

BUILDING WRAP

THROUGH WALL FLASHING

MORTAR NET

WEEP HOLES @ 33" O.C. MAX

FILL GRAVITY WITH GROUT

CLR

.0

' -

3"

CLR.0' - 3"

UNIFORM CONTINUOUS FOOTING

MIN

.

2' -

0"

LAP SHEATHING OVER JOINT

CONCRETE SLAB-ON-GRADE PER CITY OF LUBBOCK REQUIREMENTS

#3 TIES @ 24" O.C.

2-#4 BARS CONT. TOP AND BOTTOM (LAP 18" AT SPLICES)

6 MIL VAPOR RETARDER

COMPACTED FILL

10"

10"

2' - 6"

1' - 0"1' - 0"1' -

0"

0' -

4"

MINIMUM (3) #4 BARS

#4 BARS @ 16" O.C.

CONT. REINF. IN SHELTER WALLS PER PLAN DETAIL

ALTERNATE DIRECTION ON EVERY OTHER BENT #4 BAR

CONCRETE FLOOR SLAB

2'-8"

N.T

.S.

FURRING STRIPS AND INTERIOR FINISHES (TYP.)

MAX DOOR SIZE 3'-0", MAY SWING IN OR OUT

6" CMU MIN.

#4 VERTICAL BAR IN EACH CELL

GROUT ALL CELLS SOLID

REINFORCE BOND BEAM ABOVE DOOR W/(2) #4 HORIZONTAL BARS

10 GA. METAL DOOR FRAME

TEE ANCHOR (4) PER JAMB

GROUT SOLID

AT

TS

XETE FO

SA

REG

IS

TERED ARCHITEC

TWAHS

ARB

RAAS

D

55 82

M.

2

DO NOT REPRODUCE WITHOUT WRITTEN PERMISSION FROM

CLEARVIEW CUSTOM HOMES, LLC.PO BOX 64756 LUBBOCK TX 79464

806.777.0421

DATE:

DR

AW

ING

S P

RE

PA

RE

D B

Y:

SA

RA

@C

LE

AR

VIE

WC

US

TO

MH

OM

ES

.CO

M

MA

ILIN

G A

DD

RE

SS

:P

O B

OX

64

75

6

LU

BB

OC

K,

TX

79

46

4

SA

RA

BR

AD

SH

AW

, AIA

OF

FIC

E A

DD

RE

SS

:1

05

07

QU

AK

ER

AV

E.

SU

ITE

10

1L

UB

BO

CK

, T

X 7

94

23

PH

ON

E:

80

6.4

45

.12

55

A3DETAILS

07-10-17

SP

EC

DU

PLE

XS

TO

NE

BR

IDG

E -

LO

T #

124

2026

102

ND

ST

RE

ET

LUB

BO

CK

, TX

SIGNED:07-10-17

DUPLEX

1/4" = 1'-0"1

BRACED WALL PANEL - A 1/4" = 1'-0"

2BRACED WALL PANEL - B

1/4" = 1'-0"3

BRACED WALL PANEL - C 1/4" = 1'-0"

4BRACED WALL PANEL - D

1/2" = 1'-0"5

IRC WALL BRACING PROVISIONS

1 1/2" = 1'-0"6

CRICKET DIMENSIONS

3/4" = 1'-0"7

FOOTING - INTERIOR LOADBEARING WALL

3/4" = 1'-0"8

FOOTING - SPOT FOOTING ATGARAGE DOOR CORNER - PLAN

3/4" = 1'-0"9

FOOTING - SPOT FOOTING ATGARAGE DOOR CORNER -SECTION

3/4" = 1'-0"10

FOOTING - TYPICAL TWO POUREXTERIOR FOOTING

3/4" = 1'-0"11

SAFEROOM DETAIL - FOOTING 3/4" = 1'-0"

12SAFEROOM DETAIL - PLAN

No. Revision Date

Page 4: C:UsersSaraDropbox01-Residential Projects 6 102ndStonebridge - …aarondanielhomesofwesttexas.townsquareinteractive.com/... · 2017. 12. 18. · master bedrm 12' - 0" x 13' - 2" vaulted

GFI

WP

TV

M

W

G

WH

WD WHW

D

TV

TV

TV

TV

TV

TV

TV

TV

ELECTRICAL NOTES:

1. ELECTRICAL COMPONENTS & EQUIPMENT SHALL MEET OR EXCEED ALL N.E.C. AND LOCAL CODES.

2. INSTALLATIONS SHALL COMPLY WITH ALL ENTITIES HAVING JURISDICTION.3. CONTRACTOR SHALL OBTAIN OWNER APPROVAL FOR ALL FIXTURE

SELECTIONS AND LOCATIONS.4. VERIFY APPLIANCE AND EQUIPMENT ELECTRICAL REQUIREMENTS.5. VERIFY SECURITY SYSTEM & INTERCOM W/BUILDER.6. VERIFY CABLE/DATA/TELEVISION JACK LOCATIONS PRIOR TO

INSTALLATION. 7. VERIFY ALL FLOOR OUTLETS AS PER OWNER.8. VERIFY ALL LIGHTING IN KITCHEN, BREAKFAST, & LIVING ROOM.9. VERIFY ALL STEREO, INTERCOM, & COMPUTER WIRERING AS PER OWNER.10. VERIFY ALL OUTLETS ON EXTERIOR OF HOUSE.11. ALL EXTERIOR ELECTRICAL OUTLETS/FIXTURES TO BE WEATHER PROOF. 12. VERIFY ALL OUTLETS IN SOFFITS. 13. VERIFY ALL EXTERIOR TREE LIGHING & LANDSCAPE LIGHTING.14. PROVIDED LIGHTING THROUGHOUT ATTIC.15. VERIFY ELECTRICAL FOR ATTIC FANS.16. FIELD VERIFY LOCATION OF POWER TO BE BROUGHT TO HOUSE.17. ELECTRICAL AND LIGHTING LAYOUT IS REFERENCE ONLY. FINAL LAYOUT

TO BE VERIFIED BY CONTRACTOR PRIOR TO PERFORMING WORK.

SPOT LIGHT

2 LIGHT FLUORESCENT

CHANDELIER

FAN

CEILING MOUNTED FIXTURE

RECESSED CAN

VANITY LIGHT

110 OUTLET

220 OUTLET

HOSE BIB

FLOOR OUTLET

4 LIGHT FLUORESCENT

110 OUTLET - GROUND FAULT INTERUPT

110 OUTLET - WATER PROOF

HEAT/VENT/LIGHT COMBINATION

VENT/LIGHT COMBINATION

TELEPHONE JACK

TV/DATA JACK

SPOT LIGHT MOTION ACTIVATED

WALL SWITCH

SHOWER FIXTURE

THERMOSTAT

DOORBELL CHIME

PRE-WIRE GARAGE DOOR OPENER

WALL MOUNTED FIXTURE

WALL WASH RECESSED CAN

GAS BARB

ELECTRCAL LEGEND

ELECTRICAL SPECIFICATIONS:

1. PROVIDE UPLIGHTING ON TIMER IN GARAGE2. PROVIDE EAVE OUTLETS ON TIMER IN GARAGE3. PROVIDED UPLIGHTING AS PER CLEARVIEW SPECS

AT

TS

XETE FO

SA

REG

IS

TERED ARCHITEC

TWAHS

ARB

RAAS

D

55 82

M.

2

DO NOT REPRODUCE WITHOUT WRITTEN PERMISSION FROM

CLEARVIEW CUSTOM HOMES, LLC.PO BOX 64756 LUBBOCK TX 79464

806.777.0421

DATE:

DR

AW

ING

S P

RE

PA

RE

D B

Y:

SA

RA

@C

LE

AR

VIE

WC

US

TO

MH

OM

ES

.CO

M

MA

ILIN

G A

DD

RE

SS

:P

O B

OX

64

75

6

LU

BB

OC

K,

TX

79

46

4

SA

RA

BR

AD

SH

AW

, AIA

OF

FIC

E A

DD

RE

SS

:1

05

07

QU

AK

ER

AV

E.

SU

ITE

10

1L

UB

BO

CK

, T

X 7

94

23

PH

ON

E:

80

6.4

45

.12

55

E1ELECTRICAL

PLAN

07-10-17

SP

EC

DU

PLE

XS

TO

NE

BR

IDG

E -

LO

T #

124

2026

102

ND

ST

RE

ET

LUB

BO

CK

, TX

SIGNED:07-10-17

DUPLEX

1/4" = 1'-0"1

ELECTRICAL PLAN

No. Revision Date

Page 5: C:UsersSaraDropbox01-Residential Projects 6 102ndStonebridge - …aarondanielhomesofwesttexas.townsquareinteractive.com/... · 2017. 12. 18. · master bedrm 12' - 0" x 13' - 2" vaulted

WH

WD WHW

D

FOOTING NOTES:

FOLLOWING ARE ADDITIONAL COMMENT TO BUILDERS AS A REMINDER TO CONSIDER WHEN SELECTING FOUNDATION DETAILS:

1. ON LOTS THAT REQUIRE MORE THAN TWO FEET OF FILL AT ANY POINT, CHECK WITH THE INSPECTION DEPARTMENT FOR DIRECTION AS TO NEEDS FOR ENGINEERED FOUNDATION DETAILS.

2. REQUIREMENT OF SAND FILL3. REQUIREMENT OF VAPOR RETARDER4. REQUIREMENT OF PROPER FILL MATERIAL AND COMPACTION OF ALL

TRENCHES IN FOUNDATION.5. CONSIDER WHERE CONCENTRATED LOAD POINTS WILL OCCUR AND

CONSIDER ADDITIONAL CONCRETE SUPPORT AT THOSE LOCATIONS.6. ADJUST FOOTINGS AT ZERO LOT LINES NOT TO ENCROACH ON

ADJACENT LOT.7. CONSIDER FOOTINGS AND FOUNDATION DETAILS AT BASEMENT

LOCATIONS AND IT'S IMPACT ON MAIN FLOOR FOUNDATION ABOVE.8. NOTE REQUIREMENTS FOR TERMITE TREATMENT9. BUILDER SHOULD BE KNOWLEDGEABLE ABOUT EXISTING NATURAL

SOILS, INFORMATION FROM DEVELOPER OR PERFORM TEST TO DETERMINE SOILS INFORMATION PRIOR TO CONSTRUCTION ON LOT.

FR

IDG

E

FR

IDG

E

DW

DW

5FT

FIB

ER

GLASS

5FT

FIB

ER

GLASS

RECESSFLOOR 4" RECESS

FLOOR 4"

3' - 8 1/2" 12' - 7" 13' - 8 3/4" 13' - 3 1/2" 12' - 7 1/2" 3' - 8 1/2"

59' - 7 3/4"

10' -

9 1

/2"

40

' -

11"

13' -

2"

11' -

0 1

/2"

75' -

11"

15' - 1 1/2" 29' - 4 1/4" 15' - 2"

11' -

0 1

/2"

13' -

2"

40

' -

11"

10' -

9 1

/2"

1' - 10 1/2"

17' - 0"

1' - 10 1/2"

17' - 0 1/2"

4' -

6 1

3/16

"

1' -

6"

3' -

0 1

3/16

"

13' - 0 1/2" 0' - 11 3/4" 13' - 0"

18' -

3 1

/2"

19' -

9 1

/2"

9' - 3"

9' - 3"

5' - 11 1/4"

17' -

11 1

/4"

18' -

10 1

/2"

21' -

3 1

/2"

4' - 5 1/4"

12' - 3 3/4"

8' -

4 1

5/16

"

4' -

7"

2' -

5"

10' -

2 1

/4" 15

' -

4 1

/4"

15' -

11"

12' -

11 1

/4"

2' -

5 1

/4"

22' - 4 3/16" 7' - 1 5/16"

4' -

7 1

/4"

1' - 10"

3' - 7 1/2" 3' - 5"

5' - 6"

5' - 6 1/2" 3' - 5 1/2" 3' - 8 1/4"

1' - 10 1/4"

4' - 5 1/4"

12' - 3 3/4"

17' -

11 1

/4"

5' - 11 1/4"

6' -

9 1

1/16

"

19' -

7 1

/2"

8' -

4 1

5/16

"

3' - 1 3/4"

2' -

5"

4' -

7"

6' -

0"

16' - 10 1/4" 16' - 10 3/4"

6' -

0"

SLOPE AS PER SPEC SLOPE AS PER SPEC

96' - 6

1/2"

RECESSFLOOR 4"

RECESSFLOOR 4"

3' - 1"

6' -

0"

3' - 1 1/2"

6' -

0"

AT

TS

XETE FO

SA

REG

IS

TERED ARCHITEC

TWAHS

ARB

RAAS

D

55 82

M.

2

DO NOT REPRODUCE WITHOUT WRITTEN PERMISSION FROM

CLEARVIEW CUSTOM HOMES, LLC.PO BOX 64756 LUBBOCK TX 79464

806.777.0421

DATE:

DR

AW

ING

S P

RE

PA

RE

D B

Y:

SA

RA

@C

LE

AR

VIE

WC

US

TO

MH

OM

ES

.CO

M

MA

ILIN

G A

DD

RE

SS

:P

O B

OX

64

75

6

LU

BB

OC

K,

TX

79

46

4

SA

RA

BR

AD

SH

AW

, AIA

OF

FIC

E A

DD

RE

SS

:1

05

07

QU

AK

ER

AV

E.

SU

ITE

10

1L

UB

BO

CK

, T

X 7

94

23

PH

ON

E:

80

6.4

45

.12

55

F1FOUNDATION

PLAN

07-10-17

SP

EC

DU

PLE

XS

TO

NE

BR

IDG

E -

LO

T #

124

2026

102

ND

ST

RE

ET

LUB

BO

CK

, TX

SIGNED:07-10-17

DUPLEX

1/4" = 1'-0"1

FOUNDATION PLAN

No. Revision Date

Page 6: C:UsersSaraDropbox01-Residential Projects 6 102ndStonebridge - …aarondanielhomesofwesttexas.townsquareinteractive.com/... · 2017. 12. 18. · master bedrm 12' - 0" x 13' - 2" vaulted

25' FR

ONT S

ETB

ACK

5' SIDE SETBACK

5' SIDE SETBACK

6" / 12"

6" / 1

2"

6" / 12"

6" / 12"

6" / 12"

8" / 12"

6" / 1

2"

6" / 1

2"

6" / 12"

6" / 1

2"

6" / 1

2"

DR

IVEW

AY

15' R

EAR

SETB

ACK

FENCE L

INE

36' -

0"

SID

EW

ALK T

O M

ATCH E

XIS

TIN

G

8" / 1

2"

8" / 1

2"

8" / 12"

6" / 12"

6" / 1

2"

6" / 1

2"

60

' -

5 3

/4"

30

' -

2 1

/4"

13' - 10 3/16"

18' - 0"

123.48

71.57

114.40

70

.49

5.0

0

5.0

0

15.00

13.85

23.80

6" / 1

2"

AT

TS

XETE FO

SA

REG

IS

TERED ARCHITEC

TWAHS

ARB

RAAS

D

55 82

M.

2

DO NOT REPRODUCE WITHOUT WRITTEN PERMISSION FROM

CLEARVIEW CUSTOM HOMES, LLC.PO BOX 64756 LUBBOCK TX 79464

806.777.0421

DATE:

DR

AW

ING

S P

RE

PA

RE

D B

Y:

SA

RA

@C

LE

AR

VIE

WC

US

TO

MH

OM

ES

.CO

M

MA

ILIN

G A

DD

RE

SS

:P

O B

OX

64

75

6

LU

BB

OC

K,

TX

79

46

4

SA

RA

BR

AD

SH

AW

, AIA

OF

FIC

E A

DD

RE

SS

:1

05

07

QU

AK

ER

AV

E.

SU

ITE

10

1L

UB

BO

CK

, T

X 7

94

23

PH

ON

E:

80

6.4

45

.12

55

S1SITE PLAN

07-10-17

SP

EC

DU

PLE

XS

TO

NE

BR

IDG

E -

LO

T #

124

2026

102

ND

ST

RE

ET

LUB

BO

CK

, TX

SIGNED:07-10-17

DUPLEX

3/16

" =

1'-0

"1

SIT

E P

LAN

No. Revision Date