...affordable quality Consumer Units Catalogue for 2008 - 2009 Including 17th Edition

Upload: dave-holliday

Post on 06-Mar-2016

236 views

Category:

Documents


2 download

DESCRIPTION

Including 17th Edition ...affordable quality C a t a l o g u e f o r 2 0 0 8 - 2 0 0 9

TRANSCRIPT

Page 1: cume2009 final RTM

...affordable quality

Consumer Units

Ca

talo

gu

e fo

r 20

08

- 20

09

Including 17th Edition

Page 2: cume2009 final RTM

2

Consumer unitsThe new consumer unit range from CED

The new Consumer Unit range from CED has been designed with the specifier, installer and user in mind.

Enclosures and devices are coordinated to provide comprehensive circuit protection solutions, ease of installation with a stylish contemporary design to integrate within any home.

For further protection the range includes:-

n High Integrity Dual RCD Split Load Unitsn Split Load Unitsn Main Switch Unitsn Garage Units, Shower Unitsn RCD Units, MCB, RCD & RCBO

To ensure protection on all circuits and to aid usability for all, CED has taken into consideration the need of RNIB and the on - off symbols are now embossed into each unit.

Including 17th Edition High Integrity Split Load Units

From the inception of the design, CED have worked closely with contractors and electricians, to offer the homeowner products that not only provide safety and peace of mind, but that are easy to use and pleasing on the eye.

n RCD protection (will disconnect the protected circuits whenever it detects current leaking from the circuits)

n Safe and secure n MCB, RCD, RCBO to suit most combinationsn Supplied with kit, contains - Pre-printed circuit designations

Labels, Mounting Screws & Blanks

ww

w.ce

d-e

lec.co

.uk

Large Terminals

Easy small knockouts for Trunking entry

Large knockouts for easy wiring entry

Ample wire space for ease of access

Key Holes for easy mounting

Quick 1/4 turn locking mechanism

Transparent Lid

All CED consumer units have been specially designed to have completely removable Pan Assembly and Busbar for easy installation and rapid unit assembly.

Page 3: cume2009 final RTM

3Consumer Unitsn Manufactured in accordance with IEC 60439-3n 230-240v-50Hzn Modern - user friendly design quick and easy to installn Compact and robust constructionn Moulded self extinguishing ABS (flame retardant material) - Off

white colourn Polycarbonate drop down transparent cover to protect against dustn 1/4 turn quick release screw covers - (time saving)n 4 wall mounting large size key holes for easy fixingn Easy knockouts (cut outs) on the base can be removed with sharp

Stanley knife (time saving)n Generous Internal cabling space above RCBO’s (for time saving

wiring)n Easily removable pan assembly (time saving for easy wiring)n Separate earth & neutral terminals at the top for easy wiring &

identificationn Captive terminal screwsn IP20 Busbar shroudsn Easy cut - bus bar offer wider choice to the customer for selecting

split load (consumer units)n 6kA MCB to IEC60898-1 including compliance to 17th Edition

N.B. All consumer units must be fitted with CED circuit breakers.

63A RCD GU563/632

Shower Unit SU363/50

Split Load Unit CU14SL

...simple & easy to use

Consumer Unit SLRRM552

Ca

talo

gu

e fo

r 20

08

- 20

09

Page 4: cume2009 final RTM

Consumer units17th EDITION SPLIT LOAD

With fitted RCD & Main Switch

Typical Configuration

Hall

& St

air L

ight

s

Upst

airs

Lig

hts

Dow

nsta

irs S

ocke

ts

Upst

airs

Soc

kets

Cook

er

Dow

nsta

irs L

ight

s

Upst

airs

Lig

hts

Upst

airs

Soc

kets

Show

er

Burg

lar A

larm

Smok

e al

arm

s

6AMCB

6AMCB

32AMCB

32AMCB

45AMCB

30mARCD

Spare6A

MCB6A

MCB32AMCB

50AMCB

30mARCD

6A30mARCBO

6A30mARCBO

MainIsolator

Uses two RCD protected sections and a number of ways for dedicated (High Integrity Circuits) using 30mA RCBO’s.

Moulded Split Load Consumer Units17th Edition Moulded High Integrity Dual RCD Load Units (without MCB)

Code Description Specification Isolator RCDWxHxD

Dimensions (mm) MCB

SLRRM552

2x80A RCD 1x100A Main Switch 5+5 MCB on RCD 2 MCB/RCBO on Main Switch12 Way Board

BOARD-IEC604393MCB-IEC60898RCD-IEC61008

100A DP 80A DP 30mA 399x230x120 None

Moulded Dual RCD Split Load Units (without MCB)

Code Description Specification Isolator RCDWxHxD

Dimensions (mm) MCB

SLRRM662x80A RCD 1x100A Main Switch 6+6 MCB on RCD12 Way Board

BOARD-IEC604393MCB-IEC60898RCD-IEC61008

100A DP 80A DP 30mA 399x230x120 None

SLRRM44 2x80A RCD 1x100A Main Switch 4+4 MCB on RCD 8 Way Board

BOARD-IEC604393MCB-IEC60898RCD-IEC61008

100A DP 80A DP 30mA 327x230x120 None

“MCB’s supplied separately and as required by customer”.

4

Please refer to the back page of the catalogue for 17th Edition specification.

SLRRM552

ww

w.ce

d-e

lec.co

.uk

Page 5: cume2009 final RTM

Consumer unitsSPLIT LOAD

Complete with MCB

Accessory Packs Included contains: n Pre-printed circuit identification labelsn Blanksn Phase insulator

Split Load Consumer Units - 10 Way 5+5 c/w MCB - 100A Main Switch & 80Amp 2P RCD 30mA

Code Description Specification Isolator RCDWxHxD

Dimensions (mm)B Type MCB

SLRM55CB80A RCD 1x100A Main Switch 10-MCB10 Way Board

Board-IEC604393MCB-IEC60898RCD-IEC61008

100A DP 80A DP 30mA 327x230x120

3x6A MCB2x16A MCB4x32A MCB1x40A MCB

SLRM55CB/63 **

63A RCD 1x100A Main Switch 10-MCB10 Way Board

Board-IEC604393MCB-IEC60898RCD-IEC61008

100A DP 63A DP 30mA 327x230x120

3x6A MCB2x16A MCB4x32A MCB1x40A MCB

Typical Example

Outs

ide

Ligh

ts

Upst

airs

Lig

hts

Imm

ersi

on H

eate

r

Dow

nsta

irs S

ocke

ts

Show

er

Bath

room

Lig

hts

Dow

nsta

irs L

ight

s

Upst

airs

soc

kets

Kitc

hen

sock

ets

Cook

er

6AMCB

6AMCB

16AMCB

32AMCB

32AMCB

30mARCD

6AMCB

6AMCB

32AMCB

32AMCB

40AMCB

MainIsolator

With one RCD protected section with MCB’s and RCBO’s on the switch side.** To special order (available on request).

5

...affordable qualityPlease refer to the back page of the catalogue for 17th Edition specification.

Ca

talo

gu

e fo

r 20

08

- 20

09SLRM55CB

Page 6: cume2009 final RTM

6

Garage & Shower unitsComplete with MCB (Ready to use)

n RCD to BSEN61008-1n Terminal Capacity upto 352mmn MCB 6kA IEC60898-1 Single Polen IP55

Moulded Garage UnitsGarage Unit - 5 Way with 63A DP RCD 30mA & MCB

Code Description Specification Rated ConstructionWxHxD

Dimensions (mm)

GU563/632

5 Module 3 Way Moulded Garage Unit c/w 63A DP RCD 30mA 1xB6-MCB & 1B32 – MCB

IEC60439-3 IP55Moulded ABS base

TransparentPolycarbonate Cover

136x184x103

Moulded Shower Unit - 3 Way with 63A DP 30mA RCD & MCB

Code Description Specification Rated ConstructionWxHxD

Dimensions (mm)

SU363/50

3 Module 1 Way Moulded Shower Unit c/w 63A DP RCD 30mA 1xB50-MCB

IEC60439-3 IP55Moulded ABS base

TransparentPolycarbonate Cover

100x184x103

SU363/50

SU363/50GU563/632

ww

w.ce

d-e

lec.co

.uk

Page 7: cume2009 final RTM

10 Way Moulded Consumer Unit - Split Load (without MCB)c/w (A) 100A 2P Main Switch (B) 80A 2P - RCD - 30mA

Code Specification Isolator RCDWxHxD

Dimensions (mm) MCB/RCBO

CU10SL Board IEC-60439-3 100A DPIEC60947-3

80A DP 30mAEEC 61008 255x230x120

None MCB-IEC 60898RCBO-IEC61009

14 Way Moulded Consumer Unit - Split Load (without MCB)c/w (A) 100A 2P Main Switch (B) 80A 2P - RCD - 30mA

CU14SL Board IEC-60439-3 100A DP IEC60947-3

80A DP 30mA EEC 61008 327x230x120

None MCB-IEC 60898RCBO-IEC61009

18 Way Moulded Consumer Unit - Split Load (without MCB)c/w (A) 100A 2P Main Switch (B) 80A 2P - RCD - 30mA

CU18SL Board IEC-60439-3 100A DP IEC60947-3

80A DP 30mAEEC 61008 399x230x120

None MCB-IEC 60898RCBO-IEC61009

7

...simple & easy to use

CU10SLn 10 Way Consumer Unit Split Load -100A

2P Switch 80A - 2P RCD (without MCB)n 6 Spaces for MCB/RCBO

CU14SLn 14 Way Consumer Unit Split Load -100A

2P Switch 80A - 2P RCD (without MCB)n 10 Spaces for MCB/RCBO

CU18SLn 18 Way Consumer Unit Split Load -100A

2P Switch 80A - 2P RCD (without MCB)n 14 Spaces for MCB/RCBO

Consumer unitsSPLIT LOAD

Without MCB

For greater flexibility to suit your own combination of MCB/RCBO

Typical Example

Outs

ide

Ligh

ts

Upst

airs

Lig

hts

Imm

ersi

on H

eate

r

Dow

nsta

irs S

ocke

ts

Show

er

Bath

room

Lig

hts

Dow

nsta

irs L

ight

s

Upst

airs

soc

kets

Kitc

hen

sock

ets

Cook

er

30mARCD

6AMCB

6AMCB

16AMCB

32AMCB

45AMCB

6ARCBO

6ARCBO

32ARCBO

32ARCBO

40ARCBO

MainIsolator

With one RCD protected section with MCB’s and RCBO’s on the switch side.

N.B. Fitted with continuous Busbar for configuration required by the customer.

Ca

talo

gu

e fo

r 20

08

- 20

09

Page 8: cume2009 final RTM

Moulded Consumer Unit with 80A DP RCD 30mA as Main Switchfor Garage Unit or Shower Unit Application (without MCB)

Code Description Specification Rated ConstructionWxHxD

Dimensions (mm) MCB

CU4R4 Modules 2 Way Moulded Consumer Unit c/w 80A - DP RCD as Switch (MCB not included)

IEC60439-3 IP20Moulded ABS Base

Transparent Polycarbonate Cover

145x230x120 None

Moulded Consumer Unit with 100A - Main Switch as an (Isolator)

Code Description Specification Rated ConstructionWxHxD

Dimensions (mm)

VerticalKeyholeDistance

CU4S4 Module 2 Way Moulded Consumer Unit c/w 100A Switch (MCB not included)

IEC60439-3CE IP20

Moulded ABS BaseTransparent

PolycarbonateCover

145x230x120 168mm

CU8S8 Module 6 Way Moulded Consumer Unit c/w 100A Switch (MCB not included)

IEC60439-3CE IP20

Moulded ABS BaseTransparent

PolycarbonateCover

220x230x120 168mm

CU10S10 Module 8 Way Moulded Con-sumer Unit c/w 100A Switch (MCB not included)

IEC60439-3CE IP20

Moulded ABS BaseTransparent

PolycarbonateCover

255x230x120 168mm

CU14S14 Module 12 Way Moulded Consumer Unit c/w 100A Switch (MCB not in-cluded)

IEC60439-3CE IP20

Moulded ABS BaseTransparent

PolycarbonateCover

327x230x120 168mm

CU18S18 Module 16 Way Moulded Consumer Unit c/w 100A Switch (MCB not in-cluded)

IEC60439-3CE IP20

Moulded ABS BaseTransparent

PolycarbonateCover

399x230x120 168mm

Consumer unitsMAIN

With Main Switch & RCD

For low budget and flexible choice of MCB/RCBO

Metal Consumer Units -100A DP Main Switch - Isolator

Code Description Specification Rated ConstructionWxHxD

Dimensions (mm)

MCU4S 4 Ways Metal Consumer Unit c/w 100A DP isolator IEC60439-3 IP20

Metal sheet greyEpoxy painted base

TransparentPolycarbonate Cover

130x190x110

MCU14S 14 Ways Metal Consumer Unit c/w 100A DP Isolator IEC60439-3 IP20

Metal sheet greyEpoxy painted base

TransparentPolycarbonate Cover

310x190x110

8

Typical Example

Smok

e al

arm

s

Burg

lar A

larm

Upst

airs

Lig

hts

Dow

nsta

irs L

ight

s

Imm

ersi

on H

eate

r

Kitc

hen

Sock

ets

Upst

airs

Soc

kets

Dow

nsta

irs S

ocke

ts

Show

er

Cook

er

6A

30mA

RCBO

6A

30mA

RCBO

6A

30mA

RCBO

6A

30mA

RCBO

16A

30mA

RCBO

32A

30mA

RCBO

32A

30mA

RCBO

32A

30mA

RCBO

32A

30mA

RCBO

40A

30mA

RCBO

Main

Isolator

Utilising RCBO’s throughout would provide a secure dedicated 30mA protected supply to every circuit.

ww

w.ce

d-e

lec.co

.uk

CU4R

MCU4S

Page 9: cume2009 final RTM

9

...affordable quality

MCBn IEC 60898-1n Breaking Capacity -6kAn B Type Seriesn Safety Finger Proof Terminalsn Terminal Capacity Up To 35mm2 Cablen Various Rating - 6A-63A SPn Protection Against Overload / Short-Circuitn Dimension 40x18x80mm (45mm Projection)

RCBOn RCBO is a combination of RCD and MCBn RCBO to IEC61009n 30mA 6A-40Ampn Single Modulen B Type Series

MCB, RCBO & RCD unitsFor consumer units

RCD25BR

RCD40BR RCD63BR

RCD80BR

RCDSK2

RCDMSSK2

RCBO20

Ca

talo

gu

e fo

r 20

08

- 20

09

MCB - B Type 6kA SPCode Description

CUB6SP 6A-SP MCB - B Type

CUB10SP 10A-SP MCB - B Type

CUB16SP 16A-SP MCB - B Type

CUB20SP 20A-SP MCB - B Type

CUB32SP 32A-SP MCB - B Type

CUB40SP 40A-SP MCB - B Type

CUB50SP 50A-SP MCB - B Type

CUB63SP 63A-SP MCB - B Type

CUBLANK Blank for Consumer Unit

RCBO 1 Module (single module)Code Description

RCBO6 Single Modular RCBO 6A 30mA

RCBO10 Single Modular RCBO 10A 30mA

RCBO16 Single Modular RCBO 16A 30mA

RCBO20 Single Modular RCBO 20A 30mA

RCBO25 Single Modular RCBO 25A 30mA

RCBO32 Single Modular RCBO 32A 30mA

RCBO40 Single Modular RCBO 40A 30mA

RCD SocketsCode Description

RCDMSSK2 RCD Metal Clad Twin Switched Socket

RCDSK2 RCD Twin Unswitched Socket

N.B. All consumer units must be fitted with CED circuit breakers.

Page 10: cume2009 final RTM

RCD & BusbarFor consumer units

10 2 Pole RCD 25A-80ACode Description Poles Sensitivity

RCD25BR 25A DP RCD 30mA 2 30mA

RCD40BR 40A DP RCD 30mA 2 30mA

RCD63BR 63A DP RCD 30mA 2 30mA

RCD80BR 80A DP RCD 30mA 2 30mA

Busbar for Split Load/Standard Consumer UnitsCode Description Dimensions (mm)

BB3 Busbar for 3 Way -

BB10 Busbar for 10 Way 206x28x2

BB14 Busbar for 14 Way 278x28x2

BB18 Busbar for 18 Way 366x28x2

RCD (Residual Current Devices)n BSEN61008-1n RCD - Prevent fatal electric shock on a person by

reducing to “safe” levels the value and the time a person is exposed to current flowing through the body

n RCD - Protect plant & machinery from fire by a current passing from live to earth that a fuse or circuit break may not detect

n RCD should be used along with MCB to detect, short circuit and overload current

n 30mA Trip Double Polen 25A -80Amp optionsn Available in 2 Pole

General Featuresn IMQ, IEC670-1,94 Double Insulatedn Colour - Standard (RAL7035) - Whiten Material - Insulating and self extinguishing (ABS) material

for longer lifen Temperature - (-15°C to + 60°C)

Weatherproof Moulded Enclosuresn Approval IP55n Surface Mounting with hinged lid (clear tinge of Blue)n Suitable for interior and exterior use

Moulded Enclosuresn Approval IP44n Surface Mounting - Open typen Suitable for indoor use

PE5WP

PE2 PE4

ww

w.ce

d-e

lec.co

.uk

Moulded Wall Mounted (ABS) Enclosures for RCD/CB CE IMQ Approved

Code Description Modules RatedWxHxD

Dimensions (mm) No. KnockoutsFixing Centre

(mm)

PE3WP PVC Enclosure with Lid 3 IP55 83x175x114 1 (each side) 131

PE5WP PVC Enclosure with Lid 5 IP55 125x175x114 2 (each side)2 (top & bottom) 131

Moulded Wall Mounted (ABS) Enclosures for RCD/CBPE2 PVC Enclosure 2 IP44 51x130x 60 - -

PE4 PVC Enclosure 4 IP44 88x130x60 - -

PE6 PVC Enclosure 6 IP44 140x165x72 2 (each side)2 (top & bottom) -

Wall Mounted EnclosuresMOULDED

For RCD / MCB

PE6

Page 11: cume2009 final RTM

...simple & easy to use

11

Ca

talo

gu

e fo

r 20

08

- 20

09

CED Consumer Units and the 17th Edition

Under the 17th edition wiring regulations (from January 2008) the following will apply to all domestic and residential installations.

1. All socket outlets should be protected by 30mA RCD whether on ground floor of a house or the top floor of high rise apartment block.2. All circuits in a room with a fixed bath or shower should be protected by one or more 30mA RCD’s.2. All cables concealed in metal stud partitions (common in new build) should be protected by 30mA RCD’s.3. All cables buried beneath the plaster surface of a wall or partition (at less than 50mm) should be protected by 30mA RCD’s.4. Installations should be divided up into circuits so as to take account of danger and inconvenience caused by a single fault - e.g. such as a lighting circuit.4. Installations should be designed and arranged so as to prevent unwanted tripping of the RCD’s.

Note: Additional protection is provided as additional protection. It does not obviate the need for circuit protection by circuit breakers or fuses.1. Regulation 411.3.3 socket outlets with rated current not exceeding 20A that are for general use by ordinary persons.2. Regulation 701.411.3.3 Additional protection shall be provided for all circuits of the location by use of one or more 30mA RCD.3. Regulations 522.6.6 522.6.7 522.6.8 cables concealed in a wall or partition at less than 50mm depth and without earthed mechanical protection e.g. conduit.4. Regulation 314.1 Every installation shall be divided into circuits as necessary to avoid danger and inconvenience in the event of a fault. Take account of danger that may arise from failure of a single such as a lighting circuit, reduce the possibility of unwanted tripping of RCD etc.4. Regulation 314.2 Separate circuits to be provided for parts of the installation that need to be separately controlled in such a way that those circuits are not affected by the failure of other circuits.

REGULATION SUMMARY

Regulation Relating To Examples Additional Protection

411.3.3Sockets up to 20A rating

for general use by ordinary persons

Upstairs SocketsDownstairs Sockets

Kitchen SocketsCooker Outlets with Integral 13A Socket

Garage SocketsPlus and other sockets up to 20A rated

30mA RCD

701.411.3.3 All circuits in a room with a fixed bath or shower

Shower CircuitLighting CircuitHeating Circuit

Ventilation CircuitShaver Socket

Plus other Circuits

30mA RCD

522.6.6522.6.7

and522.6.8

All circuits buried in a wall or partition at less than 50mm

and without mechanical protection

Downstairs LightingUpstairs LightingImmersion Heater

Burglar AlarmsSmoke Alarms

Plus other circuits

30mA RCD

British Standards and IEE regulations are subject to change and amendments. This guide is not a substitute for the regulations which should always be used for all types of electrical installation work.

Key symbols used for codesn SL = Split Loadn CU = Consumer Unitn R = RCDn M = Main Switchn S = Main Switch

Page 12: cume2009 final RTM

Other materialWe have a range of literature that we have produced including:- LED Lighting, Site Electric’s, Professional Test Instruments and our Main Catalogue all of which can be requested. If you require a copy then please contact us at the address below.

Introducing our new 2008/2009 catalogue for our completely new range of Consumer Units, specifically manufactured to meet the very high standards required by electricians and structural engineers. Designed to provide the widest versatility whilst being robust and durable.

44-48 Freshwater Road, Dagenham Essex RM8 1RX (England)Telephone. 020 8503 8500Facsimile. 020 8503 8900www.ced-elec.co.uk - email. [email protected]

ww

w.ce

d-e

lec.co

.uk

Branch Stamp:

CED | edc1301 | 08/09

Sales Office.

44-48 Freshwater Road,

Dagenham Essex RM8 1RX. (England).

On-line.

Website. http://www.ced-elec.co.uk

E-mail. [email protected]

EDC | 002 | 05

Local Distributor

Telephone 020 8503 8500

Facsimile 020 8503 8900

PVC Tape, Fixing & Fasteners

Industrial Range

MCB/ RCD Range

Wiring Accessories

Security Systems

Testers Instruments & CableConduit Fittin

gs Metal &PVC

Desk & Ceiling Fans

Heating/Ventilation

Hand Dryers

Starters & Lamps

Battens, Floodlights & Downlighters

Site Electrics

Data Products

ASingle Source For Electrical Products!

CEDE

LECTRICAL- FEBRUARY

2005 EDITION

NO. 2

44-48 Freshwater Road, Dagenham Essex RM8 1RX.

Telephone. (020) 8503 8500 Facsimile. (0

20) 8503 8900

Website. www.ced-elec.co.uk - Email. in

[email protected]

A Single Source For Electrical products!FEBRUARY 2005 EDITION NO. 2

Buye

rs &

Spec

ifiers

Gui

de

Cover2

005.qx

d 12/

29/200

4 18:

35 Pa

ge 1

Ca

talo

gu

e fo

r 20

07

- 20

08

Professional

Test Instruments

ww

w.ce

d-e

lec.co

.uk

SITE ELECTRICS

Ca

talo

gu

e fo

r 20

07

- 20

08

Ca

talo

gu

e fo

r 20

07

- 20

08

Ca

talo

gu

e fo

r 20

07

- 20

08

44-48 Freshwater Road, Dagenham Essex RM8 1RX (England)

Telephone. 020 8503 8500 - Facsimile. 020 8503 8900

www.ced-elec.co.uk - email. [email protected]

VOLTAGE TESTERS

Professional

Test Instruments

ww

w.ce

d-e

lec.co

.uk

ww

w.ce

d-e

lec.co

.uk Branch Stamp:

MULTIMETERS

CLAMP METERS

LIGHT METERS

Introducing our new 2007/2008 catalogue with

a completely new range of professional test

instruments, specifically manufactured to meet the

very high standards required by electrical engineers.

Designed to provide the highest accuracy with many

easy to use features.

Tester Cover2.indd 2-3

11/07/2007 12:15:35

Catalo

gu

e for 2

00

7 - 2

00

8

Catalo

gu

e for 2

00

7 - 2

00

8

44-48 Freshwater Road, Dagenham Essex RM8 1RX (England)

Telephone. 020 8503 8500 - Facsimile. 020 8503 8900

www.ced-elec.co.uk - email. [email protected]

VOLTAGE TESTERS

ProfessionalTest Instruments

ww

w.ced

-elec.co.u

k

ww

w.ced

-elec.co.u

k

Branch Stamp:

MULTIMETERS

CLAMP METERS

LIGHT METERS

Introducing our new 2007/2008 catalogue with

a completely new range of professional test

instruments, specifically manufactured to meet the

very high standards required by electrical engineers.

Designed to provide the highest accuracy with many

easy to use features.

Tester Cover2.indd 2-3

11/07/2007 12:15:35

Page 13: cume2009 final RTM

Consumer Units / Moulded EnclosuresArtwork & Design by edci - copyright ©2008