Seite Nilan Presentation /
CTS 700 control
Seite Nilan Presentation /
Agenda
1. Introduction • Which products will receive the CTS 700 control
2. CTS 700 control
• Control panel • New features • User option: User • User options: Super User/Installer
3. Coming updates
Seite Nilan Presentation /
Introduction
From January 1st 2015, CTS 700 will be standard on following products:
• Comfort CT300 • Comfort CT300 Polar
• Compact P
• Compact Polar • Compact P Nordic • AIR 9 (replaces UVP5) (SCOP 5,0) • GEO 3 (SCOP 5,17) • GEO 6 (SCOP 5,15)
Seite Nilan Presentation /
CTS 700 control
Starting point
• The CTS 700 control has the same functions as CTS 602 • Some settings have to set or installed in another way • New and great features
Seite Nilan Presentation /
CTS 700 control
Control Panel
• As default delivered in white casing • It is possible to order a black casing • A mounting bracket and screws for installing is included
Seite Nilan Presentation /
CTS 700 control
Control panel
• The control panel is as standard attached with 3 m cable • A 20 m cable can be ordered as an accessory
• Cable type is: PDS Cat 5e
Seite Nilan Presentation /
CTS 700 control
Display • Larger monitor • Colour display • Great overview • Easy to navigate
• Help text
This gives a more user friendly control
Seite Nilan Presentation /
CTS 700 control
Display
Fan speed
Temperature SHW-tank
Temperatur on the solarpanel
Indoor temperatur Outdoor temperature
Clock
AIR 9
GEO 3 og 6
Main menu
Seite Nilan Presentation /
CTS 700 control
Alarm message
Warning
Seite Nilan Presentation /
CTS 700 control
Alarm message
Alarm
Seite Nilan Presentation /
CTS 700 control
Navigation • Sheer the ”wheel” right/left
• To change between main menus • Navigate up/down in sub-menus • Change setting values
• Press ”OK” to enter a menu
• And to accept an installation • A bip-tone confirms click
• Press “Arrow back” to go backward in menus
• And to exit a setting without making changes
Seite Nilan Presentation /
CTS 700 control
Menu structure
Home
Information
Settings
Standby
Fan
Temperature
Shows current main menu Help text
Sub-menu
Current setting or operation
Seite Nilan Presentation /
CTS 700 control
USB port • Software update
• Control panel • Main board • Slave board
• Language update
New software will be available as download on NilanNet
Seite Nilan Presentation /
CTS 700 control
New features Compact P with • AIR 9 • GEO 3 • GEO 6
Now only one control panel! Before: CTS 602 (Compact P) + LMC 223 (heat pump)
Seite Nilan Presentation /
CTS 700 control
Benefits with one control panel • Settings are conducted the same place • Alarms appears on the same display • The automatic is set so the ventilation and heat pump does
not work against each other • However is it possible to operate with floor heating
during the summer and at the same time ventilate in cooling mode (a ”non critical” alarm will be shown)
Seite Nilan Presentation /
CTS 700 control
New features AIR 9 can cool the home via the central heating just like GEO 3/6.
Seite Nilan Presentation /
CTS 700 control
New features Automatic log of operational data • Logs every 10. minutes
• Memory to store data for 14 days • Also logs data at the alarm time
• Possible to log data on a USB stick
• Logging can be set to a shorter range
Seite Nilan Presentation /
CTS 700 control
New features Night setback It is possible to use the week programme to set the unit to night setback, if desired. It is also possible to set the night setback via an external signal, which is activated by user option. (overrules week program)
Seite Nilan Presentation /
CTS 700 control
New features Legionella control • It is possible to start legionella control manual
• This is an advantage e.g. after a vacation where SHW production has been on standby
• It is still possible to set the unit automatically to run legionella control
Seite Nilan Presentation /
CTS 700 control
New features An expansion PCB is no longer needed. At the CTS 602 control it is often needed to purchase an expansion PCB, if extra functions were wanted. It is no longer necessary with CTS 700 since the circuit board is expanded with the necessary entry and exit points
Entry and exit points can be seen at the I/O-list, which can be downloaded from NilanNet.
Seite Nilan Presentation /
CTS 700 control
New features Control of EHD/BAH damper • EHD for energy tubes • BAH for water pre-heating element
• Measures temperature after set period e.g. every 6 hours
• Chooses the optimum intake adjusted to operation state
Roof cap
EHD damper
Energy tubes
Seite Nilan Presentation /
CTS 700 control
User – User access
Home • Standby – turn the unit on or off
(is not advisable)
Seite Nilan Presentation /
CTS 700 control
User – User access
Information • Event log (List of alarms)
• Browse log • Acknowledge event log • Event list sort mode
• Units • System state • Software version • Product
Seite Nilan Presentation /
CTS 700 control
User – User access
Settings • General settings
• Time and date
• Units • Legionella function • Filter change
• Change user level
Seite Nilan Presentation /
CTS 700 control
User – User access
Standby • Compact P
• Pause ventilation • Pause SHW production • Pause all • Standby • Auto manual operate • Heating manual operate • Cooling manual operate
• AIR 9 • Pause • Standby
Seite Nilan Presentation /
CTS 700 control
User – User access
Fan • Ventilation
• 20 – 100 %
Seite Nilan Presentation /
CTS 700 control
User – User access
Temperature • Compact P
• Air • Hot water
• AIR
• Central heating • Hot water
Seite Nilan Presentation /
CTS 700 control
Super user/installer
Home • Week programs • Compac
• Extended programs • User on/off capability* • Standby
* Only for Installer
Seite Nilan Presentation /
CTS 700 control
Super user/installer
Information • Event log (List of alarms)
• Browse log • Acknowledge event log • Delete event log* • Event list sort mode
• Units • System state • Devices • Software version • Product
*Only for Installers
Seite Nilan Presentation /
CTS 700 control
Super user/installer
Settings • Network settings • General settings
• Time and date • Language • Display • Buzzer mode
• Setings for units • Solar settings • Change user level • Service
• Software update • Super user validation • Log off to user level • Save current settings • Restore saved settings • Restore factory default • USB drive
Seite Nilan Presentation /
AllowHeat deadband – 3 °C
CTS 700 control
Super user/installer
Settings
AllowHeat deadband (°C) Allows external heating system when: Room temp (T3) < Temp. set point +/- ”AllowHeat deadband” – 1 °C Blocks external heating system when: Room temp (T3) > Temp. set point +/- ”AllowHeat deadband”
20 °C
- 1 °C
< 16 °C Allows external heating system > 17 °C Blocks external heating system
Seite Nilan Presentation /
CTS 700 control
Super user/installer
Standby • Compact P
• Pause ventilation • Pause SHW production • Pause all • Standby • Auto manual operate • Heating manual operate • Cooling manual operate
• AIR 9 • Pause • Standby
Seite Nilan Presentation /
CTS 700 control
Super user/installer
Fan • Fan speed • Fan speed offset • High fan speed enable • Low outdoor temperature • Low air humidity • High air humidity
Seite Nilan Presentation /
CTS 700 control
Super user/installer
Temperature • Summer / Winter T (°C) • Summer / Winter offset T (°C) • Night setback temp (°C) • Compact • AIR • Tpanel (°C)
Seite Nilan Presentation /
Summer/winter offset 2 °C
CTS 700 control
Super user/installer
Temperature
Summer/winter mode change
12 °C
Summer/winter offset 2 °C
Outdoor temp (T1) < 10 °C winter mode starts
Outdoor temp (T1) > 14 °C summer mode starts
Seite Nilan Presentation /
Regulate deadband 2 °C
CTS 700 control
Super user/installer
Temperature
Regulate deadband
20 °C
Regulate deadband 2 °C
Offset for cooling 2 °C Offset for bypass 1 °C
Room temp < 18 °C active heating or heating element starts
Room temp > 23 °C bypass opens
Room temp > 24 °C active cooling starts
Seite Nilan Presentation /
CTS 700 control
Coming updates • PC applikation for installers
• Give you the possebility to make a service-contract • Option for weather compensation with pre-selected graphs • Flow alarm for GEO and AIR plus common alarm • Acoustic alarm at a critical alarm • Setup guide
Seite Nilan Presentation /
CTS 700 control
Do you have further questions?