cs 9000 3d presentation
TRANSCRIPT
INTRODUCING CS 9000 3D
WHY 3D?
Benefits for your practice
Faster and more confident diagnosis:• True anatomical details
• Distortion free images, 1:1 anatomical accuracy
• Eliminate doubts from 2D exams
Predictability in surgery, improved treatment quality
Increased productivity and autonomy • In-office 3D exams– limit patient visits
Improved communication• Show patients images that are easier to understand
Increased treatment plan acceptance
3
Public© Carestream Health, 2012
2D vs. 3D: Sometimes two dimensions don’t tell the whole story
4
Panoramic image shows two supernumerary teeth in maxillary anterior
3D Volumetric view and sagittal view show precise labial location of supernumerary tooth with no resorption of the central incisor root
2D 3D
CS 9000 3D SYSTEM
Innovation, in reach
The advantages at a glance
• Affordable three-in-one solution– 3D, 2D panoramic and optional cephalometric imaging
• Highest resolution (76 µm), low dose 3D images
• Flexible 3D programs– from local exams to full-arch exams
• Compatible with guided surgery systems
6
Three-in-one solution
7
One unit for all your diagnostic needs
Panoramic imaging
3D imaging
Cephalometricimaging
User-friendly, yet powerful
1
3
2
4
5
6
Automatic 2D/3D sensor’s switch
Face-to-face positioning
High-frequency X-ray generator (90 kV)
2D panoramic imaging with variable focal trough
Motorized movements
Computer controlled system for fast and easy exams
1
2
3
4
5
6
8
3D MODALITY
FOV REGION OF INTEREST SAMPLE IMAGES RECOMMENDED APPLICATIONS
Flexible 3D programs
10
• Implantology• Impactions• Other cases involving one
dental arch• Surgical guide production
• Endodontics• Single implants• Impactions• TAD planning• Any applications requiring a
high level of detail (90μm)
5 x
3.7
cmFu
ll ar
ch
Clinical applications
Implants• Assessment of the bone’s volume
• Identify and mark critical anatomy
• Plan treatment using implant module
Endodontics• Diagnose endodontic pathosis
• Assess canal morphology
• Assessment of periapical lesions
• Evaluate root fractures and root resorption
• Plan surgeries
Diagnosis• Calcifications and fractures
• Apex / sinus connexion
• Impactions and misplaced teeth
• TMJ analysis
11
Oral surgery• Extraction
• Relationship of wisdom teeth with mandibular canals
• Cysts and periapical lesions
Orthodontics• Impactions, supernumeraries,
misplacement
• Micro implants
Implantology
12
Implant planning, full arch mode
Volumetric and sagittal views show virtual implant placement
13
Endodontics
Extensive root fracture
3D image reveals fracture not evident on PA
13
14
Endodontics
Missed 4th canal on previous endotreatment (missed MB2)
Alveolar fracture
Root resorption. 3D views show the full extent of the resorption
14
Impaction / Supernumery
15
Location of impaction, relationship to anatomical structures
Others
16
Root fracture and bone loss diagnosis
Root fracture diagnosticprior implant placement
TMJ analysis
Focused field 3D imaging
Lower radiation dose, higher resolution
• Field of view limited to a focused area (50 mm x 37 mm)
• Highest resolution in the industry (76 microns)
• Adapted information even for demanding endodontic treatments
• Exposure is confined only to the area of interest for better patient’s protection
• Aligns with ALARA principle ("As LowAs Reasonable Achievable")
17
18
High resolution advantages0.4 mm voxel
Competitive system0.3 mm voxel9500 system
0.07 mm voxelCS 9000 3D system
Smaller field of view higher resolution more precise visualization of the dental anatomy
18
Focused field 3D imaging
Exam Effective dose µSv
Equivalent daily effective dose (2400 µSv/year)
Panoramic exam * 7 to 22 1 to 3 days
3D exam performed with the CS 9000 3D system *
5 to 19 1 to 3 days
3D exam performed with other 3D systems **
68 to 600 10 to 91 days
19
Radiation dose comparison study
* Sources : Institut de la Radioprotection et de la Sûreté Nucléaire (IRSN) – Rapport 2008-07** Sources : Ludlow JB, Dosimetry of CBCT Units for Oral and Maxillofacial Radiology
Easy and fast operation
• Intuitive user interface for fast and easy exams
• Easy selection of the region of exam
• Preset programs automatically adjust exposure settings and collimation
• Fully motorized movement to easily select the region of exam
20
Easy case review and planning
• Intuitive and comprehensive 3D imaging software
• Includes sophisticated implant planning feature with implant library
• Integrates seamlessly with our other digital imaging solutions
• Fully DICOM-compliant software
• Compatible with third-party imaging software (NobelGuide™, Simplant®)
• Easy image sharing for better communication
21
Surgical guide production
Dual-scan compatible
• Compatible with guided surgery systems using double scan protocol (Simplant® and NobelGuide™)
• Exclusive user-friendly interface and scanning platform for scanning appliance
• Optimized data integration in third-party guided surgery software
• Very high image accuracy (+/- 0.5% in stitching mode)
Dedicated acquisition interface
Dedicated scanning platform
Data integration in guided surgery software
22
2D PANORAMIC IMAGING
A high-end panoramic system
• State-of-the-art technology for excellent image quality:
– Adaptable focal trough– High frequency generator– CCD sensor– Powerful image processing
• Convenient and practical face to face positioning
• 6 programs available for all examination needs
• Open design, accessible by all patients including patients in wheelchair
• Upgradeable to one shot cephalometric imaging
24
Easy and precise positioning
• Face to face positioning
–Convenient, fast and precise
–Direct visual control
• Double laser beam alignment
– Helps position the patient inside the focal trough for sharp images
• Lateral holders
– Ensure patient stability
– Prevent motion blur and retake
• Open patient positioning
–Comfortable for the patient
–Accessible by all patients, including patients in wheelchair
25
High-grade results
• Focal trough adaptable to jaw morphology for optimized image quality:
– Jaw shape
– Jaw size
– Incisor tilt
• 12 pre-programmed anatomical settings
26
Clinical results
27
Size 1 image,Bitewing
Clinical results
28
Complete set of 2D programs
29
Standard panoramic
Pediatric program
Complete set of 2D programs
30
Segmented panoramic
Maxillary sinus
Complete set of 2D programs
31
TMJx4
TMJx2
Complete set of 2D programs
32
Optional cephalometricimaging
CUSTOMER TESTIMONIALS
34
Testimonials
“The CS 9000 3D system can be considered a unique category of imaging system, rather than simply a “me too” large-field cone beam CT machine. It combines the advantages of high-resolution, low dose, limited volume 3D imaging at an affordable price.”
Allan G. Farman, BDS, PhD, DSc, Oral and Maxillofacial Radiologist, Louisville, Kentucky
“The CS 9000 3D system provides an affordable, easy-to-use ‘three-in-one’ solution. High-resolution 3D images, combined with very low dose to patients, make this system an essential contribution to dentistry.”
Prof. Dr. U. J. Rother, Imaging Diagnosis of Facial Bones, Hamburg, Germany.
34
Testimonials
35
“I don’t know how I could do without the CS 9000 3D system today. It has changed my practice from a diagnostic standpoint, and also from a therapeutic one. It even helps me with patient communication and student education.”
Dr. Jean-Yves Doukhan, Ph.D., DDS, (France) and Paris VII University Professor.
“Although we initially acquired the CS 9000 3D system for implant surgeries, we discovered a range of additional applications for the unit, such as endodontics, periodontics, and surgeries. It has significantly improved our workflow and reduced treatment time, while increasing treatment quality and patient satisfaction.”
Dr. Eduardo Salvo, Dr. José Luís Saldaña, Ph.D., DDS, Coso Medical/Dental Centre, Zaragoza (Spain).
36
Testimonials
“Because 3D exams performed with the CS 9000 3D system are low dose, the unit offers a broader range of orthodontic applications. It can be used for impactions, supernumerary teeth, wisdom teeth, or micro-implants. Focused-field 3D exams are an ideal complement to panoramic and cephalometric exams.”
Jean-Michel Foucart, Ph.D., DDS, specialised in Orthodontics and DentofacialOrthopedics. Professor at Paris 7 University in maxillo-facial imaging.
“The CS 9000 3D system, with its low dose and remarkable resolution, is an essential tool for modern endodontics. We can now visualize root canal anatomy beforehand and identify lesions or lateral canals that are not visible with periapical radiographs. Having a 3D unit that can deliver this level of anatomic details in my practice has literally changed my life.”
David Bensoussan, Ph.D., DDS, specialised in Endodontics, Paris.
36
37
Testimonials
“3-D visualization of orthodontic problems is something we used to reserve for only the most challenging of problems due to cost and radiation exposure. The CS 9000C 3D system allows us to use site-specific 3-D technology to not only treat the most complex problems, but also to improve diagnostic capability of the routine problems we treat each and every day.”
Mark Yanosky, D.D.S., M.S., Sarver and Yanosky Orthodontics, Birmingham, AL
37
More than 4,000 satisfied customers
38
With more than 4,000 sytems installed, the CS 9000 3D is probably the most popular 3D systems in the world
2010 2010 2011 20112009
New 3D module interface and 3D rendering
New full arch mode (extended mode)
New head support
New implant library New compatibility with dual scan protocol
New Film composer
2011
Evolving to meet your growing needs
39
A comprehensive range of solutions
40
2D + 3D IMAGING PAN / CEPH /
LARGE FIELD 3D
2D IMAGINGPAN / CEPH
2D + 3D IMAGINGPAN / CEPH /
FOCUSED FIELD 3D
2D + 3D IMAGING PAN / CEPH / MID FIELD 3D
Price
Field of view size / Features
CS 9300C Select (ceph)
CS 9300 Select
CS 8100
8000C (ceph)
CS 9000
CS 9000 3D
CS 9300
CS 9000C 3D (ceph)
CS 9000 C (ceph)
CS 9300C (ceph)
Technical Specifications
41
Tube voltage 60 - 90 kV (max) Pulsed mode for 3D modality
Tube current 2 - 15 mA (max)
Frequency 140 kHz (max)
Tube focal spot 0.5 mm (IEC 336)
Total filtration > 2.5 mm eq. Al
3D Modality
Technology Digital Volumetric Tomography (DVT)
Sensor technology CMOS sensor with optical fibre
Gray scale 16384 - 14 bits
Volume size Standard program 50 x 37 mmExtended mode: ~ 85mm (width) x 66mm (depth) x 37mm (height)
Voxel size 76 x 76 x 76 μm (isotropic voxel)
Reconstruction time Depends on the PC
Panoramic Modality
Sensor technology CCD Optical fibre sensor
Gray scale 16384 (14 bits)
Magnification 1.27
Exposure time Adult pan. 13.9 sec. / Pediatric pan. 13.2 sec.
Programs 12 anatomical settings
Radiological exam options • Panoramic / Segmented panoramic / Maxillary sinus / LA TMJ x2 / LA TMJ x4
Input voltage • 230-240 V - 50/60 Hz / 100-110-130V - 50/60 Hz
Weight 160 kg
Dimensions
42
CEPHALOMETRIC MODALITY
CS 9000C
p 44
The advantages at a glance
• One-shot cephalometric imaging
• Optimized image quality and radiation dose
• Broadest range of image formats
• Exclusive automatic tracings
One-shot cephalometric imaging
• Images are acquired in a single shot and in less than a second
• Minimizes distortion that is common with units using scanning technology
• Optimized image quality and reduced exposure time
• Prevents patient movement
p 45
X-ray X-ray
8 to 14 seconds +/- 1 second
SCANNING SYSTEMS CS 9300C’S ONE-SHOT
Broadest range of image formats
• Broadest range of image formats including our exclusive full skull option (30 x 30 cm)
- 30 x 30 cm, 24 x 24 cm, 24 x 24 cm, 18 x 24 cm, 18 x 18 cm
• Addresses all orthodontic diagnostic and tracing needs
• Collimation limits the exposure zone according to patient morphology or diagnostic needs
p 46
30 x 30 cm (12 x 12 in.)24 x 30 cm (10 x 12 in.)
24 x 24 cm (10 x 10 in.)18 x 24 cm (8 x 10 in.)
18 x 18 cm (8 x 8 in.)
Broadest range of image formats
p 47
Multiple image formats- 30 x 30 cm- 24 x 24 cm- 24 x 24 cm- 18 x 24 cm- 18 x 18 cm
Exclusive automatic tracings
• A software that automatically recognizes anatomical structures and landmarks and traces them in two minutes or less*
• Time saving feature allows you and your staff to focus on tasks of greater importance
• Covers the most common analysis needs (Ricketts, McNamara, Steiner, Tweed)
• Tracings can be exported to other cephalometricsoftware
p 48
Orthodontic enhancement filters
• Improve clarity and/or outline soft tissue with just one click
p 49
Optimized contrast for a primary image analysis
Bone density enhancement for clear visualization of bone and cartilage
Edges enhancement for uniform gray shades on hard and soft tissue for a fast tracing
Clinical results
p 50
Full range of cephalometric images
p 51
Lateral, frontal AP/PA, Submento-vertex, carpus views
Technical Specifications
52
Cephalometric Modality
Technology One shot
Sensor technology CCD with Optical Fiber
Gray scale 14 bits
Magnification 1.14
Exam optionsLateral, Oblique, Frontal (AP/PA), Submento-Vertex, Carpus
Multiple Cephalometric Field Choices: 30 cm x 30 cm, 24 cm x 30 cm, 24 cm x 24 cm, 18 cm x 24 cm, 18 cm x 18 cm.
Weight 438 lb (199 kg)