croton water filtration plant - fudrcroton wfp 18 flocculation, air scour and pipe gallery...
TRANSCRIPT
![Page 1: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/1.jpg)
Croton Water Filtration Plant
Dissolved Air Flotation, Filtration, and UV Facility
October 15, 2013
![Page 2: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/2.jpg)
2 Croton WFP
Existing New York City Aqueduct System
![Page 3: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/3.jpg)
3 Croton WFP
New York City Water Supply System
Croton Watershed
Croton Lake
Gate House
![Page 4: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/4.jpg)
4 Croton WFP
Croton Lake Gate House
Croton Watershed and Gate House
Croton Aqueduct - NDT Corp
![Page 5: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/5.jpg)
5 Croton WFP
New Croton Aqueduct and Jerome Park Reservoir
New Croton Lake and Dam
Croton Lake Gate House
New Croton Aqueduct (NCA)
Horseshoe Shaped 16 ft high
48 km (30 miles) long
Gravity flow (mostly not pressurized)
Approx. 16 hour delay for flow changes at GH to reach JPR
Jerome Park Reservoir (JPR)
Balances flow conveyed down NCA and WFP flow rate
Enables WFP to change flow rates to match system demands
Acts as settling basin during high turbidity events
![Page 6: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/6.jpg)
6 Croton WFP 6
Croton Water Filtration Plant
Jerome Park Reservoir
NYC Primary Aqueducts and Tunnels
![Page 7: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/7.jpg)
7 Croton WFP
Croton Dam - Old Croton Aqueduct 340 ML/d (90 mgd),
Reservoir in Manhattan 1842, decommissioned in 1950s
New Croton Dam, New Croton Aqueduct 1,135 ML/d (300 mgd),
Jerome Park Reservoir,1906
Unfiltered water - chlorine, fluoride, corrosion inhibitor,
~10% of 4,540 ML/d (1,200 mgd) average demand
Safe Drinking Water Act 1974 mandated filtration
Ozone / Diatomaceous Earth (DE) Filtration 1980s, pilot and
design
Ozone / GAC / DE Filtration early 1990s, demo and design
DAF / Ozone / Dual Media Filtration late 1990s, pilot and design
DAF / Filtration (DAFF) / UV, 2000 onwards, now under
construction in The Bronx, NYC
Completion of $2.1 billion construction project - late 2013
Croton Water System History
![Page 8: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/8.jpg)
8 Croton WFP
Plant Under Construction (July 2007)
~213 m (700 ft)
~170 m (560 ft)
Croton Water Filtration Plant (WFP) is designed to be compact and to merge
with Mosholu Golf Course, which is part of Van Cortlandt Park, in the Bronx
~30 m (100 ft)
![Page 9: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/9.jpg)
9 Croton WFP
Plant Under Construction (November 2008)
![Page 10: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/10.jpg)
10 Croton WFP
Plant Under Construction (August 2010)
![Page 11: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/11.jpg)
11 Croton WFP
Plant Under Construction (March 2011)
![Page 12: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/12.jpg)
12 Croton WFP
High Service High Pressure System (Cat/Del)
Low Service Low Pressure Gravity System
Croton WFP Process Schematic
Plant Capacity Maximum 1,100 ML/d (290 mgd)
Minimum 340 ML/d (90 mgd)
To Sewer
Coagulant (1st)
3 Stage
Mixing
Sulfuric Acid
Coagulant Aid Polymer
Coagulant (2nd)
Sodium Hypochlorite (intermittent)
Backwash Air Scour
Filtration
Dissolved Air
Flotation Flocculation
Fluoride
Filter Aid Polymer
Sodium Hypochlorite
Sodium Hydroxide
Corrosion Inhibitor
Sodium
Hypochlorite
Mix Weir
Waste Water Tank
Solids Tank
UV Wet
Well
Low Service
High Service
Recycle to Raw Water Wet Well
Raw Water
![Page 13: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/13.jpg)
13 Croton WFP
Raw Water Pump Station
Pump Data
• Six Vertical Axial Flow - 1
Stage
• Capacity 12,580 m3/h
(55,400 gpm, 80 mgd) at
14.0 m (46 ft)
• Motor – 750 kW (1,000
HP) Totally Enclosed
Water-to-Air Cooled
• Variable Frequency Drive
![Page 14: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/14.jpg)
14 Croton WFP
Raw Water Pump Station
![Page 15: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/15.jpg)
15 Croton WFP
Treated Water Pump Station
Pump Data
• Six Vertical Axial Flow - 2 Stage
• Capacity 9,150 m3/h (40,300 gpm,
58 mgd) at 51.8 m (170 ft)
• Motor – 1,865 kW (2,500 Hp)
Totally Enclosed Water-to-Air
Cooled
• Variable Frequency Drive
![Page 16: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/16.jpg)
16 Croton WFP
Treated Water Pumps
![Page 17: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/17.jpg)
17 Croton WFP
Rapid Mixing Top Entry Turbine - 3 Stages
Mixing Number of Trains and Mixing Stations - 4 (2 per half plant), 3 stages per train
Dimensions - 4.57 m by 4.57 m in plan, 3.81 m water depth
Top entry turbine type, 3 in series - Radial flow impellers, adjustable speed
Hydraulic Detention Time (HDT) - 22 seconds at maximum flow
Mixing Intensity - G = 1,000 sec-1 maximum
![Page 18: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/18.jpg)
18 Croton WFP
Flocculation, Air Scour and Pipe Gallery
Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant), 2 stages each
Dimensions - 3.96 m by 3.20 m, 3.66 m water depth
Top entry turbine type - Axial flow hydrofoil impellers, adjustable
speed
Number of stages - 2 close-coupled to DAF
HDT - 2.4 min. per stage, 4.8 min. total
Mixing Intensity – G =100 sec-1 maximum
![Page 19: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/19.jpg)
19 Croton WFP
Flocculation
![Page 20: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/20.jpg)
20 Croton WFP
DAF Recycle System
Dissolved Air Flotation - Above Filters Number of DAF Units - 48 (24 per half plant)
Dimensions - 13.41 m long by 6.71 m wide, 4.48 m
to top of media
Loading Rate - 12.2 m/h (5 gpm/ft2)
Floated Solids Removal - Rotating Skimmer
Recycle Injection - 3 manifolds per tank, fixed
orifice nozzles
![Page 21: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/21.jpg)
21 Croton WFP
DAF Recycle System
![Page 22: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/22.jpg)
22 Croton WFP
Filtration and UV – Pipe Gallery
![Page 23: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/23.jpg)
23 Croton WFP
Filters, Media, Backwash and Underdrains
Filtration (Located below DAF) Number of Filters - 48 (24 per half plant)
Dimensions -10.97 m long by 6.71 m wide
Loading Rate -15.9 m/h (6.5 gpm/ft2)
Media type and depth 0.61 m anthracite and 0.30 m silica
sand
Filter Floor/ Underdrain - Concrete monolithic plenum with
plastic nozzles
Backwash - Air scour, air/low rate wash and high rate wash
Backwash Pumps Backwash Troughs and Underdrain
Air Scour Blowers
![Page 24: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/24.jpg)
24 Croton WFP
Filtration and UV Pipe Gallery
Filtered Water
UV Unit
UV Effluent Header
![Page 25: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/25.jpg)
25 Croton WFP
UV Disinfection
UV Disinfection – Trojan UV Number of Units - 20 (10 per half plant)
Capacity and Size - 75.7 ML/d (20 mgd), 0.91 m
dia. inlet and outlet
UV System Type - Low pressure high output –
narrow spectrum
UV Transmittance > 95%
UV Reduction Equivalent Dose (RED) -
40 mJ/cm2 > 2 log Cryptosporidium inactivation
![Page 26: Croton Water Filtration Plant - FUDRCroton WFP 18 Flocculation, Air Scour and Pipe Gallery Flocculation (Close-coupled to DAF) Number of Trains and Stages - 48 (24 per half plant),](https://reader036.vdocuments.mx/reader036/viewer/2022071105/5fdef66bf389ff38473179f5/html5/thumbnails/26.jpg)
26 Croton WFP
Thank You - Questions