Phone: (800) 421-6144 • Fax: (866) 921-0531crlaurence.com • usalum.com • crl-arch.com

crlaurence.com

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

02crlaurence.com | usalum.com

PARTS IDENTIFICATION ............................................................................................................................................. 03 - 04

DOOR PREPARATION ........................................................................................................................................................05

LAYOUT SELECTION .................................................................................................................................................. 06 - 08

DOOR HARDWARE INSTALLATION .......................................................................................................................... 09 - 11

INSTALLATION OF RIM KEYED CYLINDER ..............................................................................................................09

INSTALLATION OF EXTERIOR TRIM (OPTIONAL) ...................................................................................................10

INSTALLATION OF 2095E ELECTRIC RIM LATCH ...................................................................................................11

FRAME PREPARATION AND STRIKE INSTALLATION ............................................................................................. 12 - 13

ATTACH THE STRIKE .................................................................................................................................................13

CONNECTING THE ELECTRICAL/ELECTRICAL SCHEMATICS ............................................................................. 14 - 16

PREPARE NON-ACTIVE DOOR JAMB SIDE ............................................................................................................17

CONNECTING ELECTRICAL COMPONENTS ........................................................................................................... 18 - 19

CONNECTING THE WIRES ...................................................................................................................................... 18

ARMORED DOOR LOOP INSTALLATION ................................................................................................................ 19

PACKAGE PARTS AVAILABLE .......................................................................................................................................... 20

ORDER OF ASSEMBLY AND INSTALLATION

TOOLS REQUIREDDrill Bits: 1/8", 9/32", 5/16", 7/32", 5/8", 11/16", 1-3/8"Taps: 1/4-20, 10-32, 8-32Tape MeasureSaw HorsesCordless DrillPhillips Head Screwdriver

Framing Square3/4" Masking TapeCenter PunchFlat Metal File Round Metal File Jigsaw with Metal Cutting BladeStraight Edge

NOTE:Anymodifications,otherthanthosespecifiedinthisdocument,couldresultinthisproduct'sfailuretomeetULsafetyratings andvoidthemanufacturer’swarranties.

The rapidly changing technology within the architectural aluminum products industry demands that C.R. Laurence/U.S. Aluminum reservetherighttorevise,discontinue,orchangeanyproductline,specification,orelectronicmediawithoutpriorwrittennotice.

NOTE: Dimensions in parentheses ( ) are millimeters unless otherwise noted.

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

03crlaurence.com | usalum.com

PARTS IDENTIFICATION FASTENERS PROVIDED USED WITH

CALL OUT QTY. FASTENER FASTENER

DESCRIPTION PART PART NUMBER AND DESCRIPTION

A 2 1/4"-20 x 1/4" Shoulder Stud Screws

302622 Active Head Assembly

302627 Active Head Cover Package

1 1/4"-20 x 1/4" Shoulder Stud Screw

301266 Base End

Cap Package

2 1/4"-20 x 5/16" Set Screw

302622 Active Head Assembly

302627 Active Head Cover Package

1 1/4"-20 x 5/16" Set Screw

301266 Base End

Cap Package

2 #10-32 x 5/8" Oval Head Machine Screw

302436 "C" Type SurfaceMountedStrike

2 #1/4"-20 x 1-3/4" Breakaway Screws

DL911 Rim Keyed Cylinder

2 #10-32 x 2-1/8" FHMS9500LV01 or 9500LV02

Optional Exterior Trim with Lever Assembly

8 #8 x 1-1/4" Flat Head Sheet Metal Screw

Optional MLDL101 Armored Door Loop Kit

A

B

B

C

D

E

F

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

04crlaurence.com | usalum.com

PARTS LISTCALL OUT PART PART NO. DESCRIPTION

G DL911 Optional Rim Cylinder

302436 "C"TypeSurface Mounted Strike

MLD83N Programmable Digital Keypad

302521 Wood Door Mounting Kit

MLDL101 Armored Door Loop

302616301420

Power Supply SeePages14-16forcorrectPowerSupply

301406PSC 24VDC Power Supply Converter Module

302989 Signal Switch Kit

PARTS IDENTIFICATION

1 2 3

654

7 8 9

#0*

H

I

J

K

L

M

N

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

05crlaurence.com | usalum.com

NOT TO SCALE

DOOR PREPARATION

1. Place the door horizontally on the stands interior side up. 2. Markthestilecenterlines1-1/8"(28.6)fromtheinsideedgeofthestile.(Fig. 1) 3. Markthecorrespondinglayoutsontothestileusingtheverticalcenterlinesatthespecifiedheight.(Fig. 2)

FIG. 2

Bottom Rail

Y

REMOVE DOOR AND PREPARE PER TEMPLATES

INTERIOR VIEW

SEE TEMPLATES FOR

HEIGHT DIMENSIONS

YFIG. 1

Y

Y

Y

X

X

X

Y

X

Y

1-1/8"(28.6)

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

06crlaurence.com | usalum.com

NOT TO SCALE

DOOR PREPARATION – LAYOUT SELECTION2095E EXIT DEVICE INSTALLATION - ACTIVE STILE

FIG. 3

FIG. 4

EdgeofDoor

EdgeofDoor

38-5

/32"

(969

) To

Bot

tom

ofJam

bFrom

ThisLine

Drill and Tap fora1/4"-20Machine Screw (2) Places

Drill and Counter Sinkfora7/32"Machine Screw (2) Places

Drill a 19/32" Dia. Hole

Gla

ss S

top

Gla

ss S

top

INTERIOR VIEW

ACTIVE STILE

Use Template from Box2"

(50

)

1-3/16" (30)

38-5/32" (969) To Bottom ofJambFromThis Line

EdgeofDoor

Gla

ss S

top

EdgeofDoor

Gla

ss S

top

EXTERIOR VIEW

ACTIVE STILE

Use Template from Box

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

07crlaurence.com | usalum.com

NOT TO SCALE

FIG. 5

DOOR PREPARATION – LAYOUT SELECTION2095E EXIT DEVICE INSTALLATION - INACTIVE STILE

EdgeofDoor

EdgeofDoor

Drill and Tap fora1/4"-20Machine Screw

38-5

/32"

(969

) To

Bot

tom

ofJam

bFrom

ThisLine

5/16" Dia. Hole (3) Places

1/8" Dia. Pilot Hole (4) Places

Gla

ss S

top

Gla

ss S

top

INTERIOR VIEW

INACTIVE STILE

Use Template from Box

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

08crlaurence.com | usalum.com

NOT TO SCALEFIG. 7

DOOR PREPARATION – LAYOUT SELECTION

EdgeofDoor

EdgeofDoor

Drill and Counter Sinkfora10-24FHMS (2) Places

EdgeofDoor

FIG. 6

2095E EXIT DEVICE INSTALLATION WITH EXTERIOR LEVER TRIM.

38-5

/32"

(969

) To

Bot

tom

ofJam

bFrom

ThisLine

DrillandTapfora 10-24 FHMS (2) Places

EdgeofDoor

Drill and Tap fora1/4"-20Machine Screw (2) Places

Gla

ss S

top

Gla

ss S

top

Drill a 19/32" Dia. Hole

38-5

/32"

(969

) To

Bot

tom

ofJam

bFrom

ThisLine

Gla

ss S

top

Gla

ss S

top

INTERIOR VIEW

ACTIVE STILE

Use Template from Box

Use Template from Box

EXTERIOR VIEW

ACTIVE STILE

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

09crlaurence.com | usalum.com

NOT TO SCALE

DOOR HARDWARE INSTALLATION

INSTALLATION OF RIM KEYED CYLINDER

FIG. 8

1. Inserttherimkeyedcylinderassemblyintotheactivestileandfastenwith(2)1/4"-20x1-3/4" breakaway screws (Fig. 8).

2. Attach the (2) 1/4"-20 x 1/4" shoulder stud screws to the active stile. (Fig. 8)

3. Attach (1) 1/4"-20 x 1/4" shoulder stud screw on the inactive stile. (Fig. 8)

A

D

(2) 1/4"-20 x 1/4" Shoulder Stud Screws

ACTIVE STILE

A

INACTIVE STILE

(1) 1/4"-20 x 1/4" Shoulder Stud ScrewA

Rim Keyed Cylinder

Cylinder Ring

1/4"-20 x 1-3/4" Breakaway ScrewsD

A

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

10crlaurence.com | usalum.com

NOT TO SCALE

DOOR HARDWARE INSTALLATION (CONTINUED)

FIG. 9

Attach the exterior trim to the active stile with (2) #10 x 2-1/8" FHMS.

INSTALLATION OF OPTIONAL EXTERIOR LEVER TRIM

#10 x 2-1/8" FHMS

E

E

NOTE: Exterior Trim requires useofstandard1"Mortise Cylinder with AR-MS Type Cam.

9500LV02 Flat Handle Lever Trim 9500LV01 Round Handle Lever Trim

NOTE:Exteriortrimmustbeinstalledbeforeattachingexitdevice.

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

11crlaurence.com | usalum.com

NOT TO SCALE

INSTALL 2095E ELECTRIC RIM LATCHDOOR HARDWARE INSTALLATION (CONTINUED)

FIG. 10

1. Insert the wires through the 5/16" Dia. hole on the inactive stile.

2. Installtheexitdeviceonthedoorstilesasyoufeedthewiresthroughtheupper5/16"hole.Tightenthe (1)1/4"x5/16"setscrewand(2)1/4"x5/16"setscrewoneachsideofthedoorstiles.(Fig. 10)

3. Pull the wires back through the lower 5/16" Dia. hole located below the exit device. (Fig. 11)

B B

5/16" Dia. Hole

(2) 1/4"-20 x 1/4" Shoulder Stud Screws

A

(1) 1/4"-20 x 1/4" Shoulder Stud Screw

A

Wires

(2) 1/4"-20 x 5/16" Set Screws B

ACTIVE STILE

INACTIVE STILE

(1) 1/4"-20 x 5/16" Set Screw

B

FIG. 11

5/16" Dia. Hole

Wires

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

12crlaurence.com | usalum.com

NOT TO SCALE

FRAME PREPARATION

1. Make sure that the panic exit device is in the dogged position.

2. Withthedoorintheclosedposition,markthecenterlinelocationofthePanicDeviceontheStrikeJamb.

3. Position the Strike over the center line and mark the screw hole locations. (Fig. 12)

FIG. 12

RE-ATTACH DOOR TO FRAME

Mark

Mark

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

13crlaurence.com | usalum.com

NOT TO SCALE

FRAME PREPARATION (CONTINUED)ATTACH THE STRIKE

Drillandtapfor(2)10-32x5/8"OHMSonthemarksmadeinstep3oftheframepreparationonpage12. Attach the strike to the door jamb using (2) 10-32 x 5/8" OHMS. (Fig. 13)

10-32 x 5/8" OHMS

C

CC

FIG. 13

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

14crlaurence.com | usalum.com

NOT TO SCALE

CONNECTING THE ELECTRICAL

When the exit device works properly, connect the wires to the power supply as shown in Figure 17, once the wires are properlyattachedtothepowersupplyyouneedtofeedtheproperwiresthroughthe5/16"Dia.holepreppedonthe non - active door jamb as shown on Figure 17 on Page 17.

POWER SUPPLY

ACTIVATION SWITCH

FUSE

AUTOMATIC DOOROPERATOR PANIC #1

OPERATOR PANIC #2AUTOMATIC DOOR

TO "FUSE" PANIC DEVICE #2

ACTIVATION SWITCH(REMOTE) PANIC #2

PANIC DEVICE #1

MICROSWITCHN/C YELLOW

N/O GRAYCOM RED

BLACK

RED

BLACK

RED

L1

L2

HOT120 VAC

NEUTRAL FUSE

CONDUIT REQ'DFOR GROUNDINGPULL BOX.

1406-04-AO

SOLENOID ASSY

314-28-01

REMOTE PANIC #1

+

+

24VDC (5A)10A IN-RUSH

NOTES1.) WHEN CONTACTS OF TIME CLOCK OR OVERRIDE SWITCH CLOSE. EXIT DEVICE LATCH BOLTS WILL CLOSE.2.) DENOTES A FIELD WIRE CONNECTION.

3.) RECOMMENDED WIRE Ga FROM POWER SUPPLY TO PANIC:16 Ga UP TO 40'14 Ga UP TO 60'12 Ga UP TO 100'

OUTPUT VOLTAGE FROM 110vac/120vac INPUT

FIG. 14

POWER SUPPLY NO. 302616/1406 ELECTRICAL SCHEMATICNOTE:UsedwithallJackson20ESeriesElectrifiedSolenoidLatchRetractionPanicDevicesManufacturedpriortoAugust15,2016.

ForusewithMotorizedLatchRetractionmanufacturedafterAugust15,2016,seepage15. For Power Supply No. 301420 used with Motorized Latch Retraction, See page 16.

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

15crlaurence.com | usalum.com

NOT TO SCALE

CONNECTING THE ELECTRICAL (CONTINUED)POWER SUPPLY NO. 302616/1406 ELECTRICAL SCHEMATIC

FIG. 15

The1406/1426-PSM-24VDCPowerSupplyModuleconvertsdeviceoutputvoltagefromJackson302616,ACSI Series1406suppliestoafiltered,regulated24VDCoutputforusewithJacksonSeries20EMotorDriveElectric LatchRetractionExitDevices.Uptotwodevicescanbeconnectedtothemodule'sregulatedoutput.

Installing the ModuleThe power supply module can simply be placed inside the enclosure on the bottom side at the locations shown inFigures15.Ventholesmustfaceupward,asindicatedinFigure15,toallowformaximumheatdissipation.

Vent Holes

1406-04-AO1426-04-AO

WIRE DIAGRAM

Remote Panic #1

Remote Panic #2

NOTE:UsedwithJackson20ESeriesElectrifiedMotorizedLatchRetractionPanicDevicesManufacturedafter August 15, 2016, only when powered by Power Supply model No. 302616/1406

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

16crlaurence.com | usalum.com

NOT TO SCALE

FIG. 16

POWER SUPPLY NO. 301420 ELECTRICAL SCHEMATIC

CONNECTING THE ELECTRICAL (CONTINUED)

NOTE:UsedwithJackson20ESeriesElectrifiedMotorizedLatchRetractionPanicDevicesManufacturedafterAugust15,2016. ForSolenoidLatchRetractionManufacturedbeforeAugust15,2016,SeePage14.

.

PANIC DEVICE #1

MICROSWITCHN/C YELLOW

N/O GRAYCOM RED

Motor

314-28-01WHITEWHITE

NOTES: 1.) The sum of all outputs cannot exceed 2 AMPS. 2.) When contacts of time clock or overide switch close. 3.) Denotes a Field Wire Connection. 4.) Recommended Wire Ga. from Power Supply to Panic:

WIRE GAUGE MAX. LENGTH 2-COND. CABLE

22 70 FEET

20 110 FEET

18 180 FEET

15 280 FEET

14 450 FEET

12 720 FEET

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

17crlaurence.com | usalum.com

NOT TO SCALE

Drill a 5/16" Dia. hole and Drill (4) 1/8" Dia. pilot holes. (Fig. 17)

PREPARE THE NON-ACTIVE DOOR JAMB SIDE

1/8" Dia. Pilot Hole (4 Places)

5/16" Dia. Hole

Prepped Non-Active Door Jamb 36

-1/4

" (92

0) T

o B

otto

m

ofJam

bFrom

ThisLine

FIG. 17

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

18crlaurence.com | usalum.com

NOT TO SCALE

CONNECTING ELECTRICAL COMPONENTS

CONNECTING THE WIRES

FIG.19FIG. 18

Afterpreparingnon-activedoorjamb.(Fig.17) Route the wires through the the hole on the door jamb. (Fig. 18) NextfeedthewiresthroughtheArmoredDoorLoop,andsecuretheArmoredDoorLooptothedoorjambusing (4) #8 x 1-1/4" FHSMS. (Fig. 19) OnceyouhavesecuredtheArmoredDoorLoop,connectthewiresfromtheArmoredDoorLooptotheexitdevice wires using Twist-On Wire connectors. (Fig.19)

F

Armored Door Loop

#8 x 1-1/4" FHSMS

F

Twist-On Wire Connectors

Door StileDoor Jamb

Electrical Wires

Door StileDoor Jamb

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

19crlaurence.com | usalum.com

NOT TO SCALE

CONNECTING ELECTRICAL COMPONENTS (CONTINUED)

FIG. 20

ARMORED DOOR LOOP INSTALLATIONAfterthewiresareconnected,sliptheremainingslackingwiresandtwist-onconnectorsbackintothedoorstileandintothepocketofthedoorloop.(Fig 20) Secure the door loop to the door stile using (4) #8 x 1-1/4" FHSMS. (Fig. 21)F

FIG. 21

Door StileDoor Jamb

Armored Door Loop

Pocket

Armored Door Loop

#8 x 1-1/4" FHSMS

F

Electrical Wires

Twist-On Wire Connectors

CRL JACKSON PANIC/EXIT DEVICES - 2095E ELECTRIC RIM LATCH

20crlaurence.com | usalum.com

Assembly No. Part No. Description

1 302622 Active Head Assembly-Complete

2 302627 Active Head Cover Package

3 302635 Active Head Base Plate Assembly

4 302610 Head Assembly Hardware Package

5 301064 Control Arm Hardware Package

6 302480PKG Push-Pad Package

7 301063 Base Cover Plate Package

8 301265 Push-Pad End Cap Package

9 301266 Base End Cap Package

17 302436628 "C"Type-SurfaceMountedStrike

18 302501 "S"Type-SurfaceMountedStrike

20 30SBPKG Mounting Shoulder Bolt and Set Screw Package (12 Pkg.)

PACKAGED PARTS AVAILABLE

1

2

3

4

6

7

7

8

9MECHANICAL ONLY

1817

5

20