c.r.i. submersible cables · standards conforming to pvc awg - ul 83, iec 60227, bs 6500, isi 694...
TRANSCRIPT
C .R . I . SUB MERS IB LE CA B LES 1
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
C . R . I . I S O N E A M O N G the few pioneers in the world to produce 100% stainless steel submersible
pumps. Having achieved a record production capacity of over 2 million
pumps per annum, today C.R.I. is rubbing its shoulders with the best brands
in the world, with advanced technology and safety standards as its hallmarks.
T H E B E G I N N I N G of C.R.I., way back in 1961, was a resolute attempt to produce a few irrigation
equipments using the limited facilities of an in-house foundry. Eventually the
founder's dream was coming true as the small production unit he started kept
growing rapidly. Now, after more than five eventful decades, it is an enormous,
widely reputed organization, which produces more than 2300 varieties of
perfectly engineered pumps and motors and sells its products in numerous
countries spread across 6 continents.
T H E I N F R A S T R U C T U R E of C.R.I. is pretty comprehensive with state-of-the-art machineries and
high potential in-house R&D recognised by the ministry of science and
technology, Govt. of India - all within its own covered area of 300,000 square
metres. The production environment is accredited with ISO 9001, ISO 14001
& OSHAS 18001 certifications and the products are CE, UR/UL, TSE & ISI
certified. The R&D team always stays in tune with the changing scenario and
seldom fails in coming up with outstanding solutions every time.
N E E D L E S S T O S A Y ,behind this legendary growth lies the untiring, innovative, enthusiastic and
dedicated team work. and, of course, a flawlessly maintained value system
too. The name C.R.I. itself encapsulates the company's ethos: ‘‘ Commitment,
Reliability, Innovation’’.
Pumping trust. Worldwide.
C.R.I. submersible cables are produced in a well equipped manufacturing plant using high thermal stability, bright electrolytic
copper of 99.95% purity with low conductor resistance for high current carrying capacity with superior grade rubber & PVC
compounds. Outer sheath is made up of special grade water proof PVC / Rubber compound resistant to moisture, abrasion,
grease, oil and other environment effect. C.R.I. produces different types of submersible cables in a wide range to meet the
different needs of customers across the world. C.R.I. supplies cables in both SWG and AWG dimensions. These cables are
produced keeping vagaries of field conditions voltage fluctuations into account to ensure reliability, safety, longevity and
energy saving.
C.R.I. Submersible cables
Description
99.95% EC Grade Copper High Conductivity Better Thermal Stability Abrasion Resistant PVC Compound High Ageing * * * * *property Impervious to water, oil & Grease*
Features
To supply power to submersible motors, pumping equipments & industrial machineries.
Applications
Specifications
Available sizes in Sq.mm 1.5, 2.5, 4, 6,10, 16, 25, 35, 50, 70, 95, 120 & 150 (3 core and 4 core) - 1100 V
Available sizes in AWG 14, 12, 10, 8, 6, 4, 2, 1, 1/0, 2/0, 3/0, 4/0, & 250 MCM (3 core and 4 core) - 600 V
Armoured cables sizes 1.5, 2.5, 4, 6, 10, 16, 25 & 35 (3 core and 4 core) 1100 V
available in Sq.mmO OTemperature Range -40 C to +90 C
Conductor High conductivity annealed and bunched copper
Conductor material Plain / Tinned
Conductor Resistance PVC / Rubber Std - Class 5 of IEC60228, DIN VDE 0295, IS 8130, BS 6360
is as per : PVC / Rubber AWG - Class 5 of IEC60228, UL 83, DIN VDE 0295, IS 8130, BS 6360
Armoured Cable - IS : 1554 (Part 1) 1988
Insulation material Flexible water proof PVC / Rubber
Sheath material Flexible water proof PVC / Rubber
Sheath colour Black / Blue / Green / Any other color as be specified by the customer
PVC Std - CENELEC HD 21, IEC60227, BS 6500, DIN VDE 0281, IS 694
Rubber Std - CENELEC HD 21.152, DIN VDE 0282, PART 810, IEC 245, CEI 20-19 &
BS 6007, BS 6899
Standards conforming to PVC AWG - UL 83, IEC 60227, BS 6500, ISI 694
Rubber AWG - UL 83, IEC 60245, DIN VDE 0282, PART 810, BS 6007 & BS 6899
ARMOURED POWER CABLE - IEC 60502-1, BS 5467, BS 6724
Colour Coding : PVC / Rubber Insulated & Sheathed 3 & 4 core, flat & Round (Single / Double sheathed)
Country Core colour Codes Outer sheath colour code
USA Standard- AWG
4 core - Yellow, Black, Red, Green3 core - Yellow, Black, Red
South Africa4 core - Red, Yellow, Blue, Green with Yellow stripe3 core - Red, Yellow, Blue
4 core Round / Flat - Green3 core Round / Flat - Blue
EuropeanStandard
4 core - Brown, Blue, Black, Yellow with Green stripe3 core - Brown, Blue, Black Blue
Blue
Australia 4 core - Brown, Blue, Black, Yellow with Green stripe3 core - Brown, Blue, Yellow with Green stripe Blue
Note : Do not use single sheath cables for heavy-duty applications like sewage, slurry and de-watering pumps in which the acidic fluids and chemicals may damage the sheath. Double-sheathed cables can be used for these kind of applications, whiich can be supplied on request.
Pumping trust. Worldwide.
C .R . I . SUB MERS IB LE CA B LES C .R . I . SUB MERS IB LE CA B LES 32
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N Pumping trust. Worldwide.
PVC 3 & 4 CORE FLAT CABLES
CONDUCTOR
Nominal Area inSq.mm.
1.50
2.50
4.00
6.00
10.00
16.00
25.00
35.00
50.00
70.00
95.00
120.00
150.00
22/0.30
36/0.30
56/0.30
84/0.30
140/0.30
224/0.30
350/0.30
490/0.30
703/0.30
988/0.30
1349/0.30
608/0.50
760/0.50
0.80
0.90
1.00
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.80
2.20
3.25
3.80
4.50
5.25
6.50
8.00
10.10
11.30
13.30
15.30
18.00
19.80
22.00
1.15
1.15
1.15
1.15
1.40
1.40
2.00
2.00
2.20
2.20
2.40
2.80
4.00
6.20
6.40
7.40
8.00
9.90
11.80
14.70
16.80
18.30
20.00
23.50
25.00
30.70
12.80
14.60
16.80
18.70
23.70
28.00
35.50
39.50
45.50
51.00
60.00
65.00
76.10
12.10
7.41
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.129
14
18
26
31
42
57
72
90
115
143
165
188
216
Nominal Thickness
(in mm)
Nominal Core Dia(in mm)
Nominal Thickness
(in mm)HW
Approx. OverallDimensions (in mm)
Nos. & Diaof wire
Nos./mm.
PVC INSULATION PVC SHEATH ConductorResistance
at 20°C(max)
ohms/km
CURRENTRating at
40°CAmps.
PVC 3 CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)
CONDUCTOR
1.50
2.50
4.00
6.00
10.00
16.00
25.00
35.00
50.00
70.00
95.00
120.00
22/0.30
36/0.30
56/0.30
84/0.30
140/0.30
224/0.30
350/0.30
490/0.30
703/0.30
988/0.30
1349/0.30
608/0.50
0.80
0.90
1.00
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.80
3.25
3.80
4.50
5.25
6.50
8.00
10.10
11.30
13.30
15.30
18.00
19.80
1.30
1.30
1.45
1.50
1.80
1.95
2.00
2.00
2.20
2.20
2.40
3.50
6.20
6.40
7.40
8.00
9.90
11.80
14.70
16.80
18.30
20.00
23.50
27.40
15.80
18.00
21.00
24.50
29.70
36.00
45.10
50.10
58.10
66.50
77.30
87.00
12.10
7.41
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
14
18
26
31
42
57
72
90
115
143
165
188
PVC INSULATION PVC SHEATHConductorResistance
at 20°C(max)
ohms/km
CURRENTRating at
40°CAmps.
PVC 4 CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)
Nominal Area inSq.mm.
Nominal Thickness
(in mm)
Nominal Core Dia(in mm)
Nominal Thickness
(in mm)HW
Approx. OverallDimensions (in mm)
Nos. & Diaof wire
Nos./mm.
CONDUCTOR
1.50
2.50
4.00
6.00
10.00
16.00
25.00
35.00
50.00
70.00
95.00
120.00
150.00
22/0.30
36/0.30
56/0.30
84/0.30
140/0.30
224/0.30
350/0.30
490/0.30
703/0.30
988/0.30
1349/0.30
608/0.50
760/0.50
0.80
0.90
1.00
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.90
2.00
3.25
3.80
4.50
5.25
6.50
8.00
10.10
11.30
13.30
15.30
18.00
19.80
22.00
1.50
1.50
1.60
1.60
2.00
2.00
2.40
2.60
3.10
3.20
3.50
3.80
4.00
10.00
11.00
13.00
14.60
18.00
21.20
26.50
29.50
34.80
39.30
45.70
50.20
55.30
12.10
7.41
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.129
14
18
26
31
42
57
72
90
115
143
165
188
216
Approx. OverallDimensions
(in mm)
PVC INSULATION PVC SHEATH ConductorResistance
at 20°C(max)
ohms/km
CURRENTRating at
40°CAmps.
PVC 3 CORE ROUND CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)
Nominal Thickness
(in mm)
Nominal Core Dia(in mm)
Nominal Thickness
(in mm)
Nominal Area inSq.mm.
Nos. & Diaof wire
Nos./mm.
PVC 3 & 4 CORE ROUND CABLES
CONDUCTOR
1.50
2.50
4.00
6.00
10.00
16.00
25.00
35.00
50.00
70.00
95.00
120.00
150.00
22/0.30
36/0.30
56/0.30
84/0.30
140/0.30
224/0.30
350/0.30
490/0.30
703/0.30
988/0.30
1349/0.30
608/0.50
760/0.50
0.80
0.90
1.00
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.90
2.00
3.25
3.80
4.50
5.25
6.50
8.00
10.10
11.30
13.30
15.30
18.00
19.80
22.00
1.50
1.65
1.65
1.65
2.00
2.00
2.40
2.60
3.10
3.20
3.50
3.80
4.00
10.80
12.50
14.10
16.00
20.35
23.40
29.20
32.40
38.25
43.30
50.40
55.30
61.00
12.10
7.41
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.129
14
18
26
31
42
57
72
90
115
143
165
188
216
PVC INSULATION PVC SHEATH ConductorResistance
at 20°C(max)
ohms/km
CURRENTRating at
40°CAmps.
PVC 4 CORE ROUND CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)
Approx. OverallDimensions
(in mm)
Nominal Thickness
(in mm)
Nominal Core Dia(in mm)
Nominal Thickness
(in mm)
Nominal Area inSq.mm.
Nos. & Diaof wire
Nos./mm.
C .R . I . SUB MERS IB LE CA B LES C .R . I . SUB MERS IB LE CA B LES 54
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N Pumping trust. Worldwide.
RUBBER 3 & 4 CORE FLAT CABLES
CONDUCTOR
1.50
2.50
4.00
6.00
10.00
16.00
25.00
35.00
50.00
70.00
95.00
120.00
150.00
22/0.30
36/0.30
56/0.30
84/0.30
140/0.30
224/0.30
350/0.30
490/0.30
703/0.30
988/0.30
1349/0.30
608/0.50
760/0.50
0.80
0.90
1.00
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.80
2.20
3.25
3.80
4.50
5.25
6.50
8.00
10.10
11.30
13.30
15.30
18.00
19.80
22.00
1.15
1.15
1.15
1.15
1.40
1.40
2.00
2.00
2.20
2.20
2.40
2.80
4.00
6.20
6.40
7.40
8.00
9.90
11.80
14.70
16.80
18.30
20.00
23.50
25.00
30.70
12.80
14.60
16.80
18.70
23.70
28.00
35.50
39.50
45.50
51.00
60.00
65.00
76.10
12.10
7.41
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.129
RUBBER INSULATION
RUBBER SHEATH ConductorResistance
at 20°C(max)
ohms/km
CURRENTRating at
40°CAmps.
RUBBER 3 CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)
14
18
26
31
42
57
72
90
115
143
165
188
216
Nominal Area inSq.mm.
Nominal Thickness
(in mm)
Nominal Core Dia(in mm)
Nominal Thickness
(in mm)HW
Approx. OverallDimensions
(in mm)
Nos. & Diaof wire
Nos./mm.
CONDUCTOR
1.50
2.50
4.00
6.00
10.00
16.00
25.00
35.00
50.00
70.00
95.00
120.00
22/0.30
36/0.30
56/0.30
84/0.30
140/0.30
224/0.30
350/0.30
490/0.30
703/0.30
988/0.30
1349/0.30
608/0.50
0.80
0.90
1.00
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.80
3.25
3.80
4.50
5.25
6.50
8.00
10.10
11.30
13.30
15.30
18.00
19.80
1.30
1.30
1.45
1.50
1.80
1.95
2.00
2.00
2.20
2.20
2.40
3.50
6.20
6.40
7.40
8.00
9.90
11.80
14.70
16.80
18.30
20.00
23.50
27.40
15.80
18.00
21.00
24.50
29.70
36.00
45.10
50.10
58.10
66.50
77.30
87.00
12.10
7.41
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
RUBBER INSULATION RUBBER SHEATHConductorResistance
at 20°C(max)
ohms/km
CURRENTRating at
40°CAmps.
RUBBER 4 CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)
14
18
26
31
42
57
72
90
115
143
165
188
Nominal Area inSq.mm.
Nominal Thickness
(in mm)
Nominal Core Dia(in mm)
Nominal Thickness
(in mm)HW
Approx. OverallDimensions
(in mm)
Nos. & Diaof wire
Nos./mm.
CONDUCTOR
1.50
2.50
4.00
6.00
10.00
16.00
25.00
35.00
50.00
70.00
95.00
120.00
150.00
22/0.30
36/0.30
56/0.30
84/0.30
140/0.30
224/0.30
350/0.30
490/0.30
703/0.30
988/0.30
1349/0.30
608/0.50
760/0.50
0.80
0.90
1.00
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.90
2.00
3.25
3.80
4.50
5.25
6.50
8.00
10.10
11.30
13.30
15.30
18.00
19.80
22.00
1.50
1.50
1.60
1.60
2.00
2.00
2.40
2.60
3.10
3.20
3.50
3.80
4.00
10.00
11.00
13.00
14.60
18.00
21.20
26.50
29.50
34.80
39.30
45.70
50.20
55.30
12.10
7.41
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.129
RUBBER INSULATION RUBBER SHEATH ConductorResistance
at 20°C(max)
ohms/km
CURRENTRating at
40°CAmps.
RUBBER 3 & 4 CORE ROUND CABLES
RUBBER 3 CORE ROUND CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)
Rubber
Rubber
Rubber
Rubber
Rubber
Rubber
14
18
26
31
42
57
72
90
115
143
165
188
216
Nominal Area inSq.mm.
Nominal Thickness
(in mm)
Nominal Core Dia(in mm)
Nominal Thickness
(in mm)
Approx. OverallDimensions
(in mm)
Nos. & Diaof wire
Nos./mm.
CONDUCTOR
1.50
2.50
4.00
6.00
10.00
16.00
25.00
35.00
50.00
70.00
95.00
120.00
150.00
22/0.30
36/0.30
56/0.30
84/0.30
140/0.30
224/0.30
350/0.30
490/0.30
703/0.30
988/0.30
1349/0.30
608/0.50
760/0.50
0.80
0.90
1.00
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.90
2.00
3.25
3.80
4.50
5.25
6.50
8.00
10.10
11.30
13.30
15.30
18.00
19.80
22.00
1.50
1.65
1.65
1.65
2.00
2.00
2.40
2.60
3.10
3.20
3.50
3.80
4.00
10.80
12.50
14.10
16.00
20.35
23.40
29.20
32.40
38.25
43.30
50.40
55.30
61.00
12.10
7.41
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.129
RUBBER INSULATION RUBBER SHEATH ConductorResistance
at 20°C(max)
ohms/km
CURRENTRating at
40°CAmps.
RUBBER 4 CORE ROUND CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)
14
18
26
31
42
57
72
90
115
143
165
188
216
Nominal Area inSq.mm.
Nominal Thickness
(in mm)
Nominal Core Dia(in mm)
Nominal Thickness
(in mm)
Approx. OverallDimensions
(in mm)
Nos. & Diaof wire
Nos./mm.
C .R . I . SUB MERS IB LE CA B LES C .R . I . SUB MERS IB LE CA B LES 76
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N Pumping trust. Worldwide.
3 CORE
EPDM RUBBER INSULATED & EPDM / NBR RUBBER SHEATHED ROUND CABLES 3 & 4 CORE - DOUBLE SHEATHED
Conductor Area
(in Sq.mm)Nominal)
No. of strands and
Diameter(Nominal)
Thickness ofInsulation (in mm)
(Nominal)
Thickness ofSheath(in mm)
(Nominal)
Maximum Overall
Dimensions(in mm)
Maximum Conductor Resistance
Oat 20 C Ohms/km
Current Carrying Capacity
Oat 40 C in Amps
1.50
2.50
4.00
6.00
10.00
16.00
25.00
35.00
50.00
70.00
95.00
22/0.30
36/0.30
56/0.30
84/0.30
140/0.30
226/0.30
354/0.30
495/0.30
703/0.30
440/0.45
475/0.50
0.80
0.90
1.00
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.50
1.50
1.60
1.60
2.00
2.00
2.15
2.15
2.25
2.45
2.40
10.00
11.00
13.00
14.60
18.00
21.20
26.00
28.30
33.50
37.80
43.50
12.10
7.41
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
14
18
26
31
42
57
72
90
115
143
165
4 CORE
Conductor Area
(in Sq.mm)Nominal)
No. of strands and
Diameter(Nominal)
Thickness ofInsulation (in mm)
(Nominal)
Thickness ofSheath(in mm)
(Nominal)
Maximum Overall
Dimensions(in mm)
Maximum Conductor Resistance
Oat 20 C Ohms/km
Current Carrying Capacity
Oat 40 C in Amps
1.50
2.50
4.00
6.00
10.00
16.00
25.00
35.00
50.00
70.00
95.00
22/0.30
36/0.30
56/0.30
84/0.30
140/0.30
226/0.30
354/0.30
495/0.30
703/0.30
440/0.45
475/0.50
0.80
0.90
1.00
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.50
1.65
1.65
1.65
2.00
2.00
2.20
2.20
2.30
2.60
2.65
10.80
12.50
14.10
16.00
20.35
23.40
28.80
31.50
37.30
42.20
48.80
12.10
7.41
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
14
18
26
31
42
57
72
90
115
143
165
NBR - Nitrile butadiene rubber.Cables with EPDM Insulation & NBR Sheath is equivalent to H07RN-F Standards.Cables on request with lead free NBR Sheath also can be supply on additional cost.
Note : The number of strands are approximate and strands diameter is nominal ; Conductor resistance is as per class 5 of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360 In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.
ConductorSize
(AWG)
No. ofConductor
Nos. & Dia.of wire
Core Dia.(mm)
Nominal Sheth
Thickness (mm)
MaximumOverall
Dimenssions (in mm)
Current CarryingCapacity
at 40°C in Amps
W H
3
3
3
3
3
3
3
3
3
3
3
3
3
41 x 0.254
65 x 0.254
105 x 0.254
168 x 0.254
226 x 0.254
420 x 0.254
665 x 0.254
817 x 0.254
1045 x 0.254
1330 x 0.254
1672 x 0.254
2116 x 0.254
646 x 0.5
3.60
4.30
5.10
6.30
7.60
9.90
11.10
13.60
13.60
15.60
18.00
19.80
20.60
1.15
1.15
1.15
1.40
1.40
2.00
2.00
2.20
2.20
2.20
2.40
2.65
2.80
13.30
15.60
17.70
22.30
26.30
32.30
35.90
45.50
45.50
51.00
61.00
65.00
68.00
6.20
7.00
7.40
9.30
10.60
13.10
14.30
18.30
18.30
20.00
23.50
25.50
28.00
15
20
30
50
65
85
115
130
150
175
175
230
255
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250 MCM
HEAVY DUTY PVC JACKETED FLAT SUBMERSIBLE PUMP CABLES ( WITHOUT GROUND)
PVC Jacket
PVC Jacket
PVC insulation of cores
PVC AWG SUBMERSIBLE PUMP CABLES
PVC
without ground flat cable with ground flat cable
ConductorSize
(AWG)
No. ofConductor
Nos. & Dia.of wire
Ground ConductorSize (AWG)
Core Dia.(mm)
Nominal Sheath
Thickness(mm)
Maximum Overall
Dimensions (in mm)
Current CarryingCapacityat 40°C in AmpsW H
3
3
3
3
3
3
3
3
3
3
3
3
41 x 0.254
65 x 0.254
105 x 0.254
168 x 0.254
226 x 0.254
420 x 0.254
665 x 0.254
817 x 0.254
1045 x 0.254
1330 x 0.254
1672 x 0.254
2116 x 0.254
3.85
4.50
5.30
6.50
8.00
10.10
11.30
13.60
15.60
18.00
18.00
19.80
1.15
1.15
1.15
1.40
1.40
2.00
2.00
2.20
2.20
2.20
2.65
3.85
15
20
30
50
65
85
115
130
150
175
175
230
18.00
21.00
24.30
29.70
36.00
45.10
50.10
58.10
58.10
66.50
77.30
87.00
6.50
7.60
7.90
9.90
11.80
14.70
16.20
19.00
19.00
21.50
23.50
27.80
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
14
12
10
10
8
8
6
6
6
6
2
2
HEAVY DUTY PVC JACKETED FLAT SUBMERSIBLE PUMP CABLES ( WITH GROUND)
C .R . I . SUB MERS IB LE CA B LES C .R . I . SUB MERS IB LE CA B LES 98
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N Pumping trust. Worldwide.
ConductorSize
(AWG)
No. ofConductor
Nos. & Dia.of wire
CoreDia.
(mm)
Nominal Sheath
Thickness(mm)
3
3
3
3
3
3
3
3
3
3
3
3
3
41 x 0.254
65 x 0.254
105 x 0.254
168 x 0.254
226 x 0.254
420 x 0.254
665 x 0.254
817 x 0.254
1045 x 0.254
1330 x 0.254
1672 x 0.254
2116 x 0.254
2503 x 0.254
3.85
4.50
5.30
6.50
8.00
10.10
11.30
13.60
13.60
15.60
18.00
19.80
20.60
1.15
1.15
1.15
1.40
1.40
2.00
2.00
2.20
2.20
2.20
2.40
2.65
2.80
14.60
16.80
18.70
23.70
28.00
35.50
39.50
45.50
45.50
51.00
60.00
65.00
68.00
6.40
7.40
7.90
9.90
11.40
14.70
16.20
18.30
18.30
20.00
23.50
25.00
28.00
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250 MCM
Heavy Duty Rubber Jacketed Flat Submersible Pump Cables ( Without Ground)
Rubber Jacket
without ground flat cable with ground flat cable
Rubber Jacket
Rubber insulation of cores
RUBBER AWG SUBMERSIBLE PUMP CABLES
Maximum OverallDimenssions
(in mm)
W H
Current CarryingCapacityat 40°C in Amps
15
20
30
50
65
85
115
130
150
175
175
230
255
ConductorSize
(AWG)
No. ofConductor
Nos. & Dia.of wire
Ground ConductorSize (AWG)
Core Dia.(mm)
Nominal Sheath
Thickness(mm)
3
3
3
3
3
3
3
3
3
3
3
3
41 x 0.254
65 x 0.254
105 x 0.254
168 x 0.254
266 x 0.254
420 x 0.254
665 x 0.254
817 x 0.254
1045 x 0.254
1330 x 0.254
1672 x 0.254
2116 x 0.254
3.85
4.50
5.30
6.50
8.00
10.10
11.30
13.60
15.60
18.00
19.80
19.80
1.15
1.15
1.15
1.40
2.00
2.00
2.20
2.20
2.20
2.20
3.85
3.85
18.00
21.00
24.30
29.70
36.00
45.10
50.10
58.10
58.10
66.50
77.30
87.00
6.50
7.60
7.90
9.90
11.80
14.70
16.20
19.00
19.00
21.50
23.50
27.80
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
14
12
10
10
8
8
6
6
6
4
2
2
Heavy Duty Rubber Jacketed Flat Submersible Pump Cables ( With Ground)
Maximum Overall
Dimenssions (in mm)
W H
Current CarryingCapacityat 40°C in Amps
15
20
30
50
65
85
115
130
150
175
175
230
ARMOURED POWER CABLES
3 Core Copper conductor XLPE Insulated PVC sheathed Armoured Cable
Size (No. of
Core x Nom.Area of
Conductor)
ConductorConfiguration
No./Dia ofWire
Max. ConductorResistance
oat 20 C Ohm/Km.
NominalInsulationThickness
in mm
Armour Size in mm
Nominal Sheath
Thickness in mm
OverallDiameter
in mm
Current Carrying Capacity in Amps
Ground Air
3C x 1.5
3C x 2.5
3C x 4
3C x 6
3C x 10
3C x 16
3C x 25
3C x 35
3C x 50
3C x 70
3C x 95
3C x 120
3C x 150
3C x 185
3C x 240
3C x 300
3C x 400
1/1.38
1/1.79
1/2.24
1/2.78
7/1.35
7/1.72
7/2.18
7/2.52
7/3.02
19/2.18
19/2.52
19/2.85
19/3.21
37/2.52
37/2.85
37/3.21
61/2.88
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.047
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2
-
-
-
-
-
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
1.8
1.8
1.8
1.8
1.8
1.8
2
2
2
2.2
2.2
2.2
2.4
2.6
2.8
3
3.4
14
15
16
17
19.5
21.5
22.5
24
27.5
31
35.5
38.5
42
46.5
52
61.5
64
26
27
45
56
74
95
122
146
173
212
254
287
321
362
418
469
528
23
24
41
52
70
89
119
147
179
226
279
320
365
422
500
574
662
1100 Volts grade, Copper Flexible Conductor, XLPE Insulated, Cores Laid up, PVC extruded inner-sheath, Galvanized Steel Wire /
Strip Armoured. Extruded PVC Sheathed power cables.
Strips(Width x
Thickness)mm
Round Diameterof wire in
mm
1.4
1.4
1.4
1.4
1.4
-
-
-
-
-
-
-
-
-
-
-
-
+Overall diameter of cable has a tolerance (±) 3mm for the above 30mm / othrewise (±) 2mm below 30mm
4 Core Copper conductor XLPE Insulated PVC sheathed Armoured Cable
Size (No. of
Core x Nom.Area of
Conductor)
ConductorConfiguration
No./Dia ofWire
Max. ConductorResistance
oat 20 C Ohm/Km.
NominalInsulationThickness
in mm
Armour Size in mm
Nominal Sheath
Thickness in mm
OverallDiameter
in mm
Current Carrying Capacity in Amps
Ground Air
4C x 1.5
4C x 2.5
4C x 4
4C x 6
4C x 10
4C x 16
4C x 25
4C x 35
4C x 50
4C x 70
4C x 95
4C x 120
4C x 150
4C x 185
4C x 240
4C x 300
4C x 400
1/1.38
1/1.79
1/2.24
1/2.78
7/1.35
7/1.72
7/2.18
7/2.52
7/3.02
19/2.18
19/2.52
19/2.85
19/3.21
37/2.52
37/2.85
37/3.21
61/2.88
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.047
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2
-
-
-
-
-
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
1.8
1.8
1.8
1.8
2
2
2
2
2.2
2.2
2.4
2.4
2.6
2.8
3.0
3.2
3.4
15
16
17
18
21
23
27
30
34
38.5
43
47.5
52.5
58
64.5
70.5
79
26
34
45
56
74
95
122
146
173
212
254
287
321
362
418
469
528
23
30
41
52
70
89
119
147
179
226
279
320
365
422
500
574
662
Strips(Width x
Thickness)mm
Round Diameterof wire in
mm
1.4
1.4
1.4
1.4
1.4
-
-
-
-
-
-
-
-
-
-
-
-
+Overall diameter of cable has a tolerance (±) 3mm for the above 30mm / othrewise (±) 2mm below 30mm
C .R . I . SUB MERS IB LE CA B LES C .R . I . SUB MERS IB LE CA B LES 1110
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N Pumping trust. Worldwide.
C.R.I. Z FIRE FR BUILDING WIRES
C.R.I. Z FIRE FR Building Wires are manufactured at its state of the art manufacturing facility located in Coimbatore, India. The
systems at the manufacturing facility are certified for ISO-9001 and the product manufactured to meet the relevant PVC cables
standards IS 694.
Conductor
These wires are manufactured using Electrolytic Grade 99.97% purity copper with more than 100% conductivity. The
conductors are drawn using state-of-the-art multiwire drawing machine as fine wires and bunched with concentricity according
to IS 8130. High purity and conductivity of copper ensures greater saving of electrical energy which helps to reduce electricity
bills.
Insulation
The bunched conductors are insulated with specially formulated and in-house manufactured FR-(Flame Retardant) PVC
compound with high oxygen index and temperature index. These properties help in restricting the spread of fire even at very
high temperatures. Wires are insulated with double layer, Natural FR PVC compound as first layer and Natural + Skin color
as second layer which gives double protection in insulation.
All wires are tested with online high voltage spark tester to ensure that there are no weak spots in the insulation, pin holes,
black spots and any other defects during extrusion. These wires meet the requirements of IS 694 with latest amendments with
improved fire performance for category C1. This ensures extra protection against electrical shocks, short circuits and fire.
Nominal Area of
Conductor
No. of strands/
Nominal Dia of wire**
Thickness ofinsulation
(Nom.)
Approx. Overall
Diameter
Current Carrying Capacity#2 Cables, Single Phase
In Conduit/Trunking
Unenclosed-Clipped directly to
a surface or oncable tray
Max. Resistance
per km O@ 20 C as
per IS 8130
sq. mm.
1.0
1.5
2.5
4.0
6.0
mm
14/0.30
22/0.30
36/0.30
56/0.30
84/0.30
mm
0.70
0.70
0.80
0.80
0.80
mm
2.70
3.00
3.60
4.00
4.60
Amps.
11
13
18
24
31
Amps.
12
16
22
29
37
ohms
18.10
12.10
7.41
4.95
3.30
Single Core, unsheathed cables in voltage grade 1100v IS 694 ISI CM/L-3406447
Standard Colours: Red, Yellow, Blue, Black, Green, Grey & White. Can also be supplied in any colour based on the request.
Standard Length: 90 Meter Coils in Protective Carton. Project Coils of 180 / 270 mtrs also available.# As per IS 3961(Part V) : 1968.** Nominal Dia to meet the Specified resistance.
FR PROPERTIES
TEST
Critical OxygenIndex
TemperatureIndex
Meets requirement of Flammability Test as per IS 694
TEST METHOD
IS 10810 : 1984;Part 58
IS 10810 : 1984;Part 64
Oxygen IndexMinimum 29%
MinimumTemperatureIndex 250°C
SPECIFIED VALUES
C .R . I . SUB MERS IB LE CA B LES C .R . I . SUB MERS IB LE CA B LES12
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N Pumping trust. Worldwide.
CONVERSION TABLE - Sq.mm, Sq.Inch , CIRCULAR MILS & AWG
Sq.mm Sq.Inch Cir.Mils AWG
1000975950
925900875
850825800
775750725
700675650
625600575
550525500
475450425
400375350
325300275
250225200
175150125
-10095
90-
85
1.5501.5111.472
1.4341.3951.356
1.3171.2791.240
1.2011.1631.124
1.0851.0461.008
0.9690.9300.891
0.8530.8140.775
0.7360.6980.659
0.6200.5810.542
0.5040.4650.526
0.3880.3490.310
0.2710.233
0.1938
-0.15500.1472
0.1395-
0.1317
197400019247001875300
82600017766001727300
167790016286001579200
152990014805001431200
138180013325001283100
123380011844001135100
10857001036400987000
937700888300839000
789600740300690900
641600592200542900
493500444200394800
345500296100246800
211600197400187530
177660167800167790
---
---
---
---
---
---
---
---
---
---
---
---
4/0--
-3/0-
Sq.mm Sq.Inch Cir.Mils AWG
807570
-6560
55-
50
45-
40
35-
30
-25-
2019.519.0
18.518.017.5
17.0-
16.5
16.015.515.0
14.514.013.5
-13.012.5
12.011.511.0
-10.510.0
0.12400.11630.1085
-0.10080.0930
0.0853-
0.0775
0.0698-
0.0620
0.0542-
0.0465
-0.0388
-
0.03100.03020.0294
0.02870.02790.0271
0.0264-
0.0256
0.02480.02400.0233
0.02250.02170.0209
-0.02010.0194
0.01860.01780.0171
-0.01630.0155
157920148050138180
133100128310118440
10857010560098700
888308369078960
690906636059220
526204935041740
394803849037510
365203552034550
335603309032560
315803060029610
286202764026650
262402566024680
236902270021710
208202073019740
-
2/0
1/0
1
2
3
4
-
-
5
-
-
6
-
7
Sq.mm Sq.Inch Cir.Mils AWG
9.59.08.5
-8.07.5
7.0-
6.5
6.05.5-
5.04.754.50
4.25-
4.0
3.753.50
-
3.253.0
2.75
-2.502.25
-2.0
1.75
-1.50
-
1.25-
1.0
0.9-
0.8
0.750.7-
0.6-
0.5
0.014720.013950.01317
-0.012400.01163
0.01085-
0.01008
0.009300.00853
-
0.007750.007360.00698
0.00659-
0.00620
0.005810.00542
-
0.005040.004650.00426
-0.003880.00349
-0.003100.00271
-0.00233
-
0.00194-
0.00155
0.00140-
0.00124
0.001160.00109
-
0.00093-
0.000775
187531776616779
165101579214805
138181309012831
118441085710380
987093778883
839082307896
740369096530
641659225429
518049354442
411039483455
326029612580
246820501974
177716201579
148113821290
11841029987
-
8
9
10
-
11
12
-
13
14
15
16
17
18
19
20To Convert :
Meters to feet
Kilometers to feet
Feet to meters
Feet to kilometers
Kilograms to pounds
Pounds to kilograms
Pounds 1000 ft. to pounds 1000 meters
Pounds 1000 ft to kilograms 1000 meters
Kilograms 1000 meters to pounds 1000 feetO OC = 5/9 ( F - 32)
Multiply by :
3.2808
3280.8
0.3048
0.0003048
2.205
0.4536
3.2808
1.4882
0.6719O OF = 32 + 5/9 ( C)
When you have a good thing going it is quite
in the fitting of things that recognitions come
our way. Several prestigious awards, which
decorate our shelf, say it all. These rewards
not only acknowledge our position as a leader
in the water pump industry but also serve as
reminders about what the customer expects
from a winner. And we, as ever, have our ears
perfectly tuned to customer expectations.
W I N N I N G W A Y S