cree engineering services testing laboratory (cestl ... · ccx. nvlap lab code 500077-0 test report...

14
NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D This report contains data that are not covered by the NVLAP accreditation. This report also contains goniometric data that was produced under subcontract by Cree Durham Technology Center, NVLAP Lab Code 500070-0. Cree, Inc | 4600 Silicon Drive | Durham, NC 27703 Page 1 of 14 Report Number: PL04043-001 Model: BXSPCxx3MEE30K-xxxxxx or XSPCxx3MEE30K-xxxxxx Date: 8/02/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Elizabeth Rodgers Cree, Inc 4600 Silicon Drive Durham, NC 27703 Prepared By: Approved By: Siddhartha Kollipara, Photometric Technician Tim Henning, Specialized Testing Manager

Upload: others

Post on 22-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

NVLAP Lab Code 500077-0

Test Report Number: PL04043-001 CESTL-R009 Rev D This report contains data that are not covered by the NVLAP accreditation. This report also contains goniometric data that was

produced under subcontract by Cree Durham Technology Center, NVLAP Lab Code 500070-0.

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 1 of 14

Report Number: PL04043-001

Model: BXSPCxx3MEE30K-xxxxxx or

XSPCxx3MEE30K-xxxxxx

Date: 8/02/2014

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation

Report

Prepared For:

Elizabeth Rodgers

Cree, Inc

4600 Silicon Drive

Durham, NC 27703

Prepared By: Approved By:

Siddhartha Kollipara, Photometric Technician Tim Henning, Specialized Testing Manager

Page 2: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

NVLAP Lab Code 500077-0

Test Report Number: PL04043-001 CESTL-R009 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 2 of 14

Product Information

Manufacturer Cree Inc Model Number (SKU) BXSPCxx3MEE30K-xxxxxx or XSPCxx3MEE30K-xxxxxx Serial Number N/A LED Type MDA

Product Description

Cast finned gray painted metal housing with cast gray painted metal access door, 1 white circuit board with 5 LEDs, 1 clear optic below each LED, formed white plastic lens retaining frame.

Driver Information (Where Applicable)

Philips ADVANCE LE098X04

Aperture Size (in): Length (in): Width (in):

5.5” x 5.5” 23.5” 9.25”

Sample

The following sample was submitted for evaluation

Page 3: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

NVLAP Lab Code 500077-0

Test Report Number: PL04043-001 CESTL-R009 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 3 of 14

Key Photometric Data Sphere Output Goniophotometer

Luminous Flux 6866 7077 lm

Efficacy 68.76 70.63 lm/W

Correlated Color Temperature (CCT) 2975 K

Color Rendering Index (CRI) 80

R9 4

Duv -0.00116

S/P Ratio* 1.27 Sphere Goniophotometer

Electrical Measurements 120V 277V 120V 277V

Input Wattage 99.86 99.15 100.20 98.62 W

Input Current .839 .389 .840 .387 A

Input Voltage 119.89 276.76 120.06 277.47 V

Power Factor .993 .921 .993 .918

Off-State Power 0 0 0 0 W

Total Harmonic Distortion (Voltage) .07 .06 .07 .07 %

Total Harmonic Distortion (Amperage) 6.96 10.11 6.90 10.09 %

Note: All photometric measurements taken at 120VAC.

Luminous Intensity Distribution Goniophotometer

Max Candela 4590.5 Cd

Angle of Max Candela (Horizontal) 45 ˚

Angle of Max Candela (Vertical) 60 ˚

Key Test Parameters Sphere Output Goniophotometer

Stabilization Time 120 69 min

Total Operating Time (Stabilization + Test) 120 89 min

Ambient Temperature 25.0 26.0 ˚C

Page 4: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

NVLAP Lab Code 500077-0

Test Report Number: PL04043-001 CESTL-R009 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 4 of 14

Chromaticity Coordinates

x y u v u’ v’ Duv

.4370 .4012 .2518 .3469 .2518 .5203 -0.00116

Color Rendering Index Details

Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14

80 78 87 94 78 77 83 83 59 4 69 76 65 80 96

Chromaticity Diagram

2700 K

3000 K

3500 K

4000 K

4500 K

5000 K

5700 K

6500 K

2975

0.29

0.31

0.33

0.35

0.37

0.39

0.41

0.43

0.28 0.30 0.32 0.34 0.36 0.38 0.40 0.42 0.44 0.46 0.48 0.50

CC

y

CCx

Page 5: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

NVLAP Lab Code 500077-0

Test Report Number: PL04043-001 CESTL-R009 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 5 of 14

Spectral Distribution

λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm

360 0.000284 530 0.071833 700 0.024683 370 0.000340 540 0.080306 710 0.018524 380 0.000323 550 0.089261 720 0.013984 390 0.000258 560 0.099478 730 0.010359 400 0.000728 570 0.111241 740 0.007675 410 0.003159 580 0.123229 750 0.005737 420 0.012259 590 0.132707 760 0.004236 430 0.029374 600 0.137454 770 0.003245 440 0.053269 610 0.136059 780 0.002460 450 0.065297 620 0.128264 790 0.001858 460 0.037139 630 0.115933 800 0.001459 470 0.022676 640 0.100814 810 0.001072 480 0.018904 650 0.084515 820 0.000823 490 0.023923 660 0.069109 830 0.000666 500 0.035954 670 0.054605 510 0.050195 680 0.042412 520 0.062243 690 0.032495

Dominant Wavelength 583 nm Peak Wavelength: 603 nm

Spectral Power Distribution (W/nm)

0

0.02

0.04

0.06

0.08

0.1

0.12

0.14

0.16

350 400 450 500 550 600 650 700 750 800 850

Ra

dia

nt

Flu

x (

W)

Wavelength (nm)

Page 6: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

NVLAP Lab Code 500077-0

Test Report Number: PL04043-001 CESTL-R009 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 6 of 14

Zonal Lumen Summary

Zone Lumens % of Total Zone Lumens % of Total 0-5 36.0 0.5% 90-95 0 0%

5-10 104.8 1.5% 95-100 0 0% 10-15 170.9 2.4% 100-105 0 0% 15-20 248.2 3.5% 105-110 0 0% 20-25 339.2 4.8% 110-115 0 0% 25-30 420.7 5.9% 115-120 0 0% 30-35 474.2 6.7% 120-125 0 0% 35-40 496.6 7.0% 125-130 0 0% 40-45 527.5 7.5% 130-135 0 0% 45-50 677.3 9.6% 135-140 0 0% 50-55 780.1 11.0% 140-145 0 0% 55-60 751.5 10.6% 145-150 0 0% 60-65 749.4 10.6% 150-155 0 0% 65-70 600.1 8.5% 155-160 0 0% 70-75 391.2 5.5% 160-165 0 0% 75-80 206.8 2.9% 165-170 0 0% 80-85 84.5 1.2% 170-175 0 0% 85-90 17.9 0.3% 175-180 0 0%

Total 7076.8 lm 100%

Page 7: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

Test Report Number:

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7

Candela Plot

Roadway Utilization

NVLAP Lab Code 500077

Test Report Number: PL04043-001

| 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Illuminance Plot

Roadway Summary

Cutoff Classification Distribution Downward Street Side Downward House Side Downward Total Upward Street Side Upward House Side Upward Total Total Lumens

NVLAP Lab Code 500077-0

CESTL-R009 Rev D

Page 7 of 14

Illuminance Plot

Lumens % Lamp

FULL CUTOFF Type III, Short

5272.1 74.5% 1804.4 25.5% 7076.6 100%

0 0% 0 0% 0 0%

7076.8 100%

Page 8: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

NVLAP Lab Code 500077-0

Test Report Number: PL04043-001 CESTL-R009 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 8 of 14

Luminaire Classification System

Page 9: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

NVLAP Lab Code 500077-0

Test Report Number: PL04043-001 CESTL-R009 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 9 of 14

Candela Tabulations **

0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5

0 1542 1542 1542 1542 1542 1542 1542 1542 1542 1542 1542 1542 1542 1542 1542 1542 1542 1542 1542

2.5 1565 1564 1573 1563 1557 1554 1548 1548 1548 1548 1548 1549 1548 1546 1540 1534 1526 1518 1513

5 1606 1612 1612 1588 1570 1556 1544 1542 1541 1540 1539 1538 1535 1532 1524 1515 1505 1494 1487

7.5 1688 1683 1688 1652 1609 1571 1534 1522 1515 1507 1503 1498 1493 1487 1477 1466 1453 1440 1432

10 1660 1675 1719 1712 1661 1585 1511 1478 1461 1444 1431 1417 1405 1393 1381 1368 1354 1341 1331

12.5 1659 1703 1814 1852 1804 1641 1485 1422 1392 1361 1335 1309 1289 1268 1253 1237 1224 1210 1199

15 1726 1770 1936 2053 2028 1789 1500 1387 1337 1287 1249 1210 1180 1151 1130 1109 1095 1081 1072

17.5 1816 1847 2021 2218 2241 2008 1595 1414 1340 1266 1214 1161 1122 1084 1062 1040 1028 1015 1013

20 1926 1938 2102 2369 2432 2235 1767 1515 1412 1310 1240 1169 1123 1077 1055 1033 1025 1018 1022

22.5 1994 2011 2197 2514 2615 2431 1972 1666 1528 1390 1298 1206 1157 1107 1091 1076 1071 1067 1077

25 2044 2059 2260 2577 2769 2596 2135 1809 1640 1472 1354 1237 1183 1129 1123 1118 1127 1135 1152

27.5 2096 2105 2280 2575 2868 2733 2217 1898 1719 1540 1399 1258 1203 1148 1154 1159 1185 1212 1237

30 2164 2159 2281 2566 2868 2808 2232 1908 1737 1567 1418 1268 1218 1168 1179 1189 1230 1271 1310

32.5 2237 2210 2266 2524 2794 2804 2182 1835 1684 1532 1400 1267 1225 1182 1194 1206 1258 1310 1365

35 2266 2226 2242 2424 2674 2725 2116 1745 1599 1454 1350 1246 1219 1191 1205 1218 1277 1336 1407

37.5 2272 2242 2221 2296 2511 2620 2051 1669 1523 1376 1296 1216 1205 1194 1211 1229 1293 1357 1442

40 2307 2278 2226 2178 2340 2512 1989 1623 1483 1343 1273 1202 1195 1187 1210 1234 1306 1377 1467

42.5 2544 2586 2316 2106 2209 2440 2025 1736 1617 1497 1436 1375 1341 1307 1318 1330 1380 1430 1500

45 3293 3289 2826 2195 2263 2583 2285 2016 1900 1783 1734 1684 1636 1588 1588 1589 1603 1618 1625

47.5 3410 3335 3367 2857 2779 3365 2778 2400 2290 2180 2127 2073 2034 1994 1973 1953 1934 1914 1855

50 2982 2938 3344 3494 3460 4085 3498 2952 2829 2707 2619 2531 2450 2370 2339 2308 2281 2255 2130

52.5 2663 2615 2745 2989 3609 4143 4100 3460 3340 3221 3091 2961 2742 2524 2425 2327 2300 2273 2128

55 2662 2614 2605 2474 3303 4003 3874 3630 3395 3160 2943 2726 2495 2264 2128 1991 1931 1872 1790

57.5 2375 2290 2445 2471 3054 4247 3551 3379 3189 2999 2793 2587 2427 2266 2155 2044 1952 1861 1746

60 2012 1956 2037 2236 3043 4590 3969 3714 3536 3359 3149 2939 2765 2592 2466 2340 2215 2089 1904

62.5 1582 1481 1675 1866 2802 4463 4285 3987 3818 3650 3403 3156 2934 2711 2530 2348 2187 2026 1844

65 940 827 1048 1451 2278 3742 4017 3884 3797 3711 3512 3314 3067 2820 2604 2388 2194 2000 1885

67.5 385 355 461 873 1571 2780 3463 3454 3430 3406 3279 3153 2927 2702 2470 2238 2047 1856 1886

70 230 216 236 348 914 1835 2662 2740 2781 2821 2805 2789 2641 2493 2289 2084 1887 1690 1826

72.5 164 154 166 177 423 1109 1921 2182 2212 2241 2246 2252 2139 2027 1869 1711 1526 1341 1469

75 142 134 127 127 175 584 1226 1527 1561 1596 1627 1658 1614 1570 1461 1353 1184 1014 1037

77.5 138 120 111 95 116 287 720 899 949 1000 1058 1116 1083 1049 963 877 768 658 627

80 95 85 81 87 93 140 343 439 468 497 542 587 570 554 491 428 374 320 304

82.5 64 57 54 61 64 76 159 222 247 272 290 309 298 287 255 222 199 176 179

85 35 29 30 30 36 42 88 118 126 135 143 150 147 144 126 108 96 85 83

87.5 12 8 6 7 8 15 28 33 35 37 40 43 43 42 36 30 27 24 23

90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Page 10: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

NVLAP Lab Code 500077-0

Test Report Number: PL04043-001 CESTL-R009 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 10 of 14

Candela Tabulations **

90 95 105 115 125 135 145 155 165 175 180

0 1542 1542 1542 1542 1542 1542 1542 1542 1542 1542 1542

2.5 1507 1506 1515 1497 1479 1472 1465 1463 1470 1458 1444

5 1480 1472 1472 1440 1411 1391 1379 1379 1386 1372 1365

7.5 1423 1411 1412 1387 1368 1356 1346 1344 1350 1340 1330

10 1321 1311 1326 1330 1336 1337 1330 1323 1327 1317 1310

12.5 1188 1186 1236 1281 1311 1324 1333 1337 1329 1321 1315

15 1063 1076 1163 1243 1306 1355 1377 1375 1360 1348 1338

17.5 1011 1038 1153 1252 1348 1417 1415 1391 1363 1345 1330

20 1026 1069 1213 1326 1432 1459 1429 1367 1312 1287 1266

22.5 1088 1142 1313 1432 1498 1475 1386 1278 1210 1188 1164

25 1169 1240 1411 1518 1526 1437 1276 1165 1105 1089 1062

27.5 1263 1352 1503 1568 1498 1316 1152 1056 993 976 948

30 1350 1458 1571 1563 1402 1176 1034 948 900 886 862

32.5 1420 1537 1612 1509 1253 1047 925 852 812 809 791

35 1478 1595 1619 1412 1107 929 825 767 738 740 726

37.5 1528 1639 1577 1275 982 828 742 695 654 638 613

40 1558 1655 1499 1126 873 748 661 578 521 497 470

42.5 1570 1637 1399 996 785 645 528 442 406 390 372

45 1633 1596 1278 884 673 513 404 353 330 319 308

47.5 1795 1628 1141 760 540 400 332 298 281 274 267

50 2004 1766 1014 634 425 328 284 261 250 244 240

52.5 1982 1709 892 524 353 281 250 235 229 229 225

55 1708 1498 733 424 298 246 225 217 212 210 207

57.5 1630 1354 589 343 256 220 206 203 197 195 193

60 1719 1300 492 290 229 201 194 195 186 186 188

62.5 1662 1205 500 292 232 203 199 197 192 194 197

65 1770 1266 571 325 239 206 202 203 201 204 208

67.5 1917 1476 621 307 221 196 201 214 222 241 252

70 1962 1687 524 259 201 198 216 241 271 296 300

72.5 1598 1528 393 228 206 212 237 265 288 273 260

75 1060 1149 339 244 225 223 245 270 256 234 230

77.5 596 675 348 256 239 224 239 249 222 201 193

80 287 373 350 252 226 184 194 195 170 148 137

82.5 182 303 294 206 145 106 139 136 110 97 88

85 82 157 159 96 78 66 76 76 75 66 58

87.5 22 45 49 26 21 20 32 39 37 14 3

90 0 0 0 0 0 0 0 0 0 0 0

Page 11: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

NVLAP Lab Code 500077-0

Test Report Number: PL04043-001 CESTL-R009 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 11 of 14

Candela Tabulations **

0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5

92.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

97.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

102.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

107.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

112.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

117.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

122.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

127.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

130 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

132.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

137.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

142.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Page 12: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

NVLAP Lab Code 500077-0

Test Report Number: PL04043-001 CESTL-R009 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 12 of 14

Candela Tabulations **

90 95 105 115 125 135 145 155 165 175 180

92.5 0 0 0 0 0 0 0 0 0 0 0

95 0 0 0 0 0 0 0 0 0 0 0

97.5 0 0 0 0 0 0 0 0 0 0 0

100 0 0 0 0 0 0 0 0 0 0 0

102.5 0 0 0 0 0 0 0 0 0 0 0

105 0 0 0 0 0 0 0 0 0 0 0

107.5 0 0 0 0 0 0 0 0 0 0 0

110 0 0 0 0 0 0 0 0 0 0 0

112.5 0 0 0 0 0 0 0 0 0 0 0

115 0 0 0 0 0 0 0 0 0 0 0

117.5 0 0 0 0 0 0 0 0 0 0 0

120 0 0 0 0 0 0 0 0 0 0 0

122.5 0 0 0 0 0 0 0 0 0 0 0

125 0 0 0 0 0 0 0 0 0 0 0

127.5 0 0 0 0 0 0 0 0 0 0 0

130 0 0 0 0 0 0 0 0 0 0 0

132.5 0 0 0 0 0 0 0 0 0 0 0

135 0 0 0 0 0 0 0 0 0 0 0

137.5 0 0 0 0 0 0 0 0 0 0 0

140 0 0 0 0 0 0 0 0 0 0 0

142.5 0 0 0 0 0 0 0 0 0 0 0

145 0 0 0 0 0 0 0 0 0 0 0

147.5 0 0 0 0 0 0 0 0 0 0 0

150 0 0 0 0 0 0 0 0 0 0 0

152.5 0 0 0 0 0 0 0 0 0 0 0

155 0 0 0 0 0 0 0 0 0 0 0

157.5 0 0 0 0 0 0 0 0 0 0 0

160 0 0 0 0 0 0 0 0 0 0 0

162.5 0 0 0 0 0 0 0 0 0 0 0

165 0 0 0 0 0 0 0 0 0 0 0

167.5 0 0 0 0 0 0 0 0 0 0 0

170 0 0 0 0 0 0 0 0 0 0 0

172.5 0 0 0 0 0 0 0 0 0 0 0

175 0 0 0 0 0 0 0 0 0 0 0

177.5 0 0 0 0 0 0 0 0 0 0 0

180 0 0 0 0 0 0 0 0 0 0 0

Page 13: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

NVLAP Lab Code 500077-0

Test Report Number: PL04043-001 CESTL-R009 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 13 of 14

Integrating Sphere Equipment List

Description Manufacturer Model Serial Number

3M Sphere Labsphere CSTM-CSLMS-3M98-HDS 82456

CCD Array Spectrometer Otsuka MC-9801 98010165

Programmable AC Source Quadtech 31005 QT3100500136

Power Analyzer Xitron 2801 28011012004

Goniophotometer Equipment List

Description Manufacturer Model Serial Number

AC Power Source Adaptive FC210 2300229 AC Power Source Elgar CW1251 1126A06399

Type C Goniophotometer LSI / UL 6440T 6440TE0192T

Spectroradiometer Gooch & Housego 770VIS/NIR 11414155

Test Methods Used:

Title Description

ANSI C82.77:2002 Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment

CIE Pub. 13.3:1995 Method of Measuring and Specifying Color Rendering of Light Sources

CIE Pub. 15:2004 Colorimetry

IES LM-58:1994 Spectroradiometric Measurements

IES LM-65:2001 Single-Ended Compact Fluorescent Lamps – Life Test Performance

IES LM-79:2008 Electrical and Photometric Measurements of Solid-State Lighting Products

Reference Standard Used:

Equipment Description

3m Sphere Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number H111

Type C Goniophotometer Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Number 97A

Page 14: Cree Engineering Services Testing Laboratory (CESTL ... · CCx. NVLAP Lab Code 500077-0 Test Report Number: PL04043-001 CESTL-R009 Rev D C r e e , I n c | 4 6 0 0 S i l i c o n D

NVLAP Lab Code 500077-0

Test Report Number: PL04043-001 CESTL-R009 Rev D

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Page 14 of 14

Disclaimers:

This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.

The results contained in this report pertain only to the tested sample.

This report shall not be reproduced, except in full, without written approval of the CESTL.

Items marked with an asterisk are not covered by the NVLAP accreditation.

In the event that the recorded temperature is outside of 25 + 1˚C, this is considered a non-standard condition

** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as “Goniophotometer”, were performed by the subcontracted laboratory identified in the footer on the first page of this report. Subcontracted testing is strictly goniophotometer based. All other tests are performed using an integrating sphere.

The goniophotometer information in the equipment list, report items marked with **, or results specifically identified as “Goniophotometer”, are the actual equipment used, and test results produced, by the subcontracted laboratory.

Additional Comments: This luminaire was tested in the Base Up orientation.

Integrating Sphere setup Goniophotometer setup