cprt series - electromec · ss-gcprt 5 product specifications performance ratings 1) certifi ed...

8
PRODUCT SPECIFICATIONS SS-GCPRT www.goodmanmfg.com 7/05 Supercedes 2/05 Split System Heat Pump The CPRT split system heat pump is designed for ground-level or rooftop mount applications. Standard Features • High-efciency Copeland ® scroll compressor • Louvered guard protects coil from damage and adds strength to the unit • Bottom pan rails elevate the unit above slab • 8-pole, 850-RPM motor • 4-bladed fan • Copper tube, aluminum n coil • Brass liquid and suction service valves mounted at a 45° angle with sweat connections and service ports • Fully charged for 15’ of tubing length • Factory-installed liquid line lter drier • Discharge line mufer • Suction line accumulator • Check-owrater expansion device • Time-initiated, temperature-terminated defrost control • Low-pressure control for loss-of-charge protection • Contactor with lug connection • Ground lug connection Air Handler and Coil Compatibilities • AEPT, ARPT and ARUF multi-position electric heat air handlers • MBR/MBE modular blower • CA, CH and H indoor coils CPRT SERIES 13 SEER Cabinet Construction • Polyester powder paint provides premium durability and improved UV protection • Heavy-gauge, zinc-clad, G90 galvanized steel • When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds Accessories • Standard Room Thermostat with 1-stage cool/2-stage heat (HPT18-60) • Digital Room Thermostat with 1-stage cool/ 2-stage heat (CHTP18-60HD) • Outdoor Lockout Thermostat/Emergency Heat Relay Kit for staging electric heat (OT/ EHR18-60) • Outdoor Thermostat (OT18-60); required for all heat pumps if outdoor ambient temperature is 0˚F with 50% or higher relative humidity 2 to 5 Ton

Upload: phamdang

Post on 08-Jun-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CPRT SERIES - ELECTROMEC · SS-GCPRT 5 PRODUCT SPECIFICATIONS Performance Ratings 1) Certifi ed per ARI 210/240 @ 80 °F/67 °F/95 °F 2) TVA Rating 3) Seasonal Energy Effi ciency

PRODUCT SPECIFICATIONS

SS-GCPRT www.goodmanmfg.com 7/05 Supercedes 2/05

Split SystemHeat Pump

The CPRT split system heat pump is designed for ground-level or rooftop mount applications.

Standard Features• High-effi ciency Copeland® scroll compressor• Louvered guard protects coil from damage

and adds strength to the unit• Bottom pan rails elevate the unit above slab• 8-pole, 850-RPM motor• 4-bladed fan• Copper tube, aluminum fi n coil• Brass liquid and suction service valves

mounted at a 45° angle with sweat connections and service ports

• Fully charged for 15’ of tubing length• Factory-installed liquid line fi lter drier• Discharge line muffl er• Suction line accumulator• Check-fl owrater expansion device• Time-initiated, temperature-terminated

defrost control• Low-pressure control for loss-of-charge

protection• Contactor with lug connection• Ground lug connection

Air Handler and Coil Compatibilities• AEPT, ARPT and ARUF multi-position

electric heat air handlers• MBR/MBE modular blower• CA, CH and H indoor coils

CPRT SERIES13 SEER

Cabinet Construction• Polyester powder paint provides premium

durability and improved UV protection• Heavy-gauge, zinc-clad, G90 galvanized

steel• When properly anchored, meets the

2001 Florida Building Code unit integrity requirements for hurricane-type winds

Accessories• Standard Room Thermostat with 1-stage

cool/2-stage heat (HPT18-60)• Digital Room Thermostat with 1-stage cool/

2-stage heat (CHTP18-60HD)• Outdoor Lockout Thermostat/Emergency

Heat Relay Kit for staging electric heat (OT/EHR18-60)

• Outdoor Thermostat (OT18-60); required for all heat pumps if outdoorambient temperature is 0˚F with 50%or higher relative humidity

2 to 5 Ton

Page 2: CPRT SERIES - ELECTROMEC · SS-GCPRT 5 PRODUCT SPECIFICATIONS Performance Ratings 1) Certifi ed per ARI 210/240 @ 80 °F/67 °F/95 °F 2) TVA Rating 3) Seasonal Energy Effi ciency

2 SS-GCPRT

PRODUCT SPECIFICATIONSSpecifi cations

Model

CPR

T24-

1

CPR

T30-

1

CPR

T36-

1

CPR

T42-

1

CPR

T48-

1

CPR

T60-

1

ServiceValve

Liquid 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”

Suction 3/4” 3/4” 7/8” 7/8” 7/8” 7/8”

Type Sweat Sweat Sweat Sweat Sweat Sweat

Shipping Weight (lbs) 137 142 152 162 249 337

Electrical Data

Volts 208/230 208/230 208/230 208/230 208/230 208/230

Phase 1 1 1 1 1 1

Hz 60 60 60 60 60 60

Minimum Circuit Amps1 14.5 17.8 20.1 23 24.6 29.2

Maximum Overcurrent Protection2 20 30 30 40 40 50

Minimum Volts 197 197 197 197 197 197

Maximum Volts 253 253 253 253 253 253

CompressorRLA 10.9 13.5 14.8 17.1 18.4 22.1

LRA 54 72.5 83 95 109 137

Condenser Fan

FLA 0.9 0.9 1.6 1.6 1.6 1.6

HP 1/6 1/6 1/6 1/6 1/6 1/6

1) Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes

2) May use fuses or HACR type Circuit Breakers of the same size as noted

Page 3: CPRT SERIES - ELECTROMEC · SS-GCPRT 5 PRODUCT SPECIFICATIONS Performance Ratings 1) Certifi ed per ARI 210/240 @ 80 °F/67 °F/95 °F 2) TVA Rating 3) Seasonal Energy Effi ciency

SS-GCPRT 3

PRODUCT SPECIFICATIONSDimensions for CPRT24-42 Models

FORMED INTO BOTTOM PAN ELEVATED CHANNEL

ADDITIONAL 1-1/2"

LIQUID CONN.

29"

CPRT24 = 30" CPRT36 = 27.5" CPRT42 = 30"

7/8" DIA. CONTROL

CPRT30 = 25"

1-1/8" DIA. POWER

SUCTION CONN.

29"

Page 4: CPRT SERIES - ELECTROMEC · SS-GCPRT 5 PRODUCT SPECIFICATIONS Performance Ratings 1) Certifi ed per ARI 210/240 @ 80 °F/67 °F/95 °F 2) TVA Rating 3) Seasonal Energy Effi ciency

4 SS-GCPRT

PRODUCT SPECIFICATIONS

CPRT48-1 = 30" CPRT60-1 = 35"

35.5" 35.5"

ADDITIONAL 1-1/2" ELEVATED CHANNELFORMED INTO BOTTOM PAN

SUCTION CONN.

LIQUID CONN.

1-1/8" DIA. POWER7/8" DIA. CONTROL

Dimensions for CPRT48-60 Models

Page 5: CPRT SERIES - ELECTROMEC · SS-GCPRT 5 PRODUCT SPECIFICATIONS Performance Ratings 1) Certifi ed per ARI 210/240 @ 80 °F/67 °F/95 °F 2) TVA Rating 3) Seasonal Energy Effi ciency

SS-GCPRT 5

PRODUCT SPECIFICATIONSPerformance Ratings

1) Certifi ed per ARI 210/240 @ 80 °F/67 °F/95 °F2) TVA Rating3) Seasonal Energy Effi ciency Ratio4) Energy Effi ciency Ratio @ 80 °F/67 °F/95 °F5) HSPF = Heating Seasonal Performance Factor6) Order the EEP from the Service Department using Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38

is not interchangeable with B13707-35S.XX designates electric heat quantityWhen mix-matching outdoor and indoor units, the indoor unit check-fl owrator must match the outdoor unit size.

Model Coil / Air Handler

Cooling Capacity Heating CapacityARI

Ref. #

Dec

ibel

s

Total BTUH

Sens

ible

B

TUH

SEER

EER 47°F

(BTUH)47°F COP H

SPF 17°F

(BTUH)17°F COP

CPR

T24-

1

AEPT030-00*-1* 22,800 17,000 14 12.6 23,000 3.5 7.5 11,500 2.5 539694

74

ARPT032-00*-1* 22,800 17,000 13 11.6 23,000 3.3 7.7 11,500 2.3 539735

ARUF032-00*-1* 22,800 17,000 13 11.6 23,000 3.3 7.7 11,500 2.3 539765

CA*F030*2*+EEP 22,800 17,000 13 11.6 23,000 3.3 7.3 11,500 2.28 539685

CA*F042*2*+EEP 22,800 17,000 13 11.6 23,000 3.3 7.3 11,500 2.28 539746

CHPF030A2*+EEP 22,800 17,000 13 11.6 23,000 3.3 7.3 11,500 2.28 539717

CHPF042B2*+EEP 22,800 17,000 13 11.6 23,000 3.3 7.3 11,500 2.28 539808

H36F+EEP 22,800 17,000 13 11.6 23,000 3.3 7.5 11,500 2.3 539771

CPR

T30-

1

AEPT030-00*-1* 29,000 22,300 13.5 12 30,000 3.42 8 18,000 2.52 539719

79

AEPT036-00*-1* 30,000 26,000 14 12.5 31,000 3.5 8.5 19,000 2.6 539708

ARPT032-00*-1* 29,000 22,300 13 11.6 30,000 3.3 8 18,000 2.4 539801

ARUF032-00*-1* 29,000 22,300 13 11.6 30,000 3.3 8 18,000 2.4 539793

CA*F030*2*+EEP 30,000 23,000 13 11.6 30,000 3.3 7.8 18,000 2.4 539762

CA*F042*2*+EEP 30,000 23,000 13 11.6 30,000 3.3 7.8 18,000 2.4 539751

CHPF030A2*+EEP 30,000 22,300 13 11.6 30,000 3.3 7.8 18,000 2.4 539757

CHPF042B2*+EEP 30,000 22,300 13 11.6 30,000 3.3 7.8 18,000 2.4 539752

H36F+EEP 29,000 22,300 13 11.6 30,000 3.3 7.8 18,000 2.4 539761

CPR

T36-

1

AEPT036-00*-1* 35,000 25,300 14 12.6 37,000 3.5 8.5 21,000 2.3 539780

79

ARPT049-00*-1* 35,000 25,300 13 11.6 36,000 3.5 8 20,000 2.3 539787

ARUF048-00*-1* 35,000 25,300 13 11.6 36,000 3.5 8 20,000 2.3 539809

ARUF049-00*-1* 35,000 25,300 13 11.6 36,000 3.5 8 20,000 2.3 539775

CA*F048*2*+EEP 35,000 25,300 13 11.6 36,000 3.48 8 20,000 2.28 539807

CHPF048D2*+EEP 35,000 25,300 13 11.6 36,000 3.48 8 20,000 2.28 539736

H60F+EEP 35,000 25,300 13 11.6 36,000 3.5 8 20,000 2.3 539792

Page 6: CPRT SERIES - ELECTROMEC · SS-GCPRT 5 PRODUCT SPECIFICATIONS Performance Ratings 1) Certifi ed per ARI 210/240 @ 80 °F/67 °F/95 °F 2) TVA Rating 3) Seasonal Energy Effi ciency

6 SS-GCPRT

PRODUCT SPECIFICATIONS

Model Coil / Air Handler

Cooling Capacity Heating CapacityARI

Ref. #

Dec

ibel

s

Total BTUH

Sens

ible

B

TUH

SEER

EER 47°F

(BTUH)47°F COP H

SPF 17°F

(BTUH)17°F COP

CPR

T42-

1

AEPT060-00*-1* 40,000 30,400 14 12.6 41,000 3.8 8.5 23,000 2.5 539742

79

ARPT049-00*-1* 39,000 29,600 13 11.6 40,000 3.6 8.4 22,400 2.3 539709

ARUF049-00*-1* 39,000 29,600 13 11.6 40,000 3.6 8.4 22,400 2.3 539802

CA*F060*2*+EEP 39,000 29,600 13 11.6 40,000 3.6 8.4 22,400 2.28 539776

CHPF060D2*+EEP 39,000 29,600 13 11.6 40,000 3.6 8.4 22,400 2.28 539723

H61F+EEP 39,000 29,600 13 11.6 40,000 3.6 8.4 22,400 2.3 539806

CPR

T48-

1

AEPT060-00*-1* 46,500 33,500 13.5 12 46,000 3.5 8.6 30,400 2.6 531554

79

ARPT061-00*-1* 46,500 33,500 13 11.6 46,000 3.5 8.5 30,400 2.5 531549

ARUF061-00*-1* 46,500 33,500 13 11.6 46,000 3.5 8.5 30,400 2.5 531544

CA*F048*2*+EEP 42,500 30,600 12 10.6 42,000 3.48 8 28,000 2.28 531542

CA*F060*2*+EEP 43,500 31,400 12.5 11 43,000 3.48 8.2 28,000 2.28 531559

CA*F061*2*+EEP 46,000 33,000 13 11.6 45,000 3.48 8.4 30,000 2.28 532778

CHPF060D2*+EEP 46,000 33,000 13 11.6 45,000 3.48 8.4 33,000 2.28 531545

H61F+EEP 46,000 33,000 13 11.6 45,000 3.5 8.4 30,000 2.3 531536

CPR

T60-

1

AEPT060-00*-1* 55,000 40,000 13 11.6 55,000 3.5 8.5 35,000 2.6 531533

79

ARPT061-00*-1* 55,000 40,000 13 11.6 55,000 3.5 8.4 35,000 2.5 531532

ARUF061-00*-1* 55,000 40,000 13 11.6 55,000 3.5 8.4 35,000 2.5 531547

CA*F061*2*+EEP 54,000 39,400 13 11.6 54,000 3.4 8.4 34,000 2.4 531548

CHPF060D2*+EEP 54,000 39,400 13 11.6 54,000 3.48 8.4 34,000 2.4 531551

H61F+EEP 54,000 39,400 13 11.6 54,000 3.5 8.4 34,000 2.4 531541

1) Certifi ed per ARI 210/240 @ 80 °F/67 °F/95 °F2) TVA Rating3) Seasonal Energy Effi ciency Ratio4) Energy Effi ciency Ratio @ 80 °F/67 °F/95 °F5) HSPF = Heating Seasonal Performance Factor6) Order the EEP from the Service Department using Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38

is not interchangeable with B13707-35S.XX designates electric heat quantityWhen mix-matching outdoor and indoor units, the indoor unit check-fl owrator must match the outdoor unit size.

Performance Ratings

Page 7: CPRT SERIES - ELECTROMEC · SS-GCPRT 5 PRODUCT SPECIFICATIONS Performance Ratings 1) Certifi ed per ARI 210/240 @ 80 °F/67 °F/95 °F 2) TVA Rating 3) Seasonal Energy Effi ciency

SS-GCPRT 7

PRODUCT SPECIFICATIONS

Heating Performance Expanded Ratings@ 70 °F Indoor Ambient

CP * T 3 0 - 1 V S . AEPT030/AE30-XX

0 50 00 1 00 00 1 50 00 2 00 00 2 50 00 3 00 00 3 50 00 4 00 00 4 50 00

62 5 7 52 47 4 2 3 7 32 27 2 2 17 1 2 7 2 - 3 OU T S I D E

de g F

0 1 2 3 4 5

CP*T30-1 VS.

U/ UC32+EEP, U/ UC42+EEP,

H 36F + E E P ,

0 5000 1 0000 1 5000 2 0000 2 5000 3 0000 3 5000 4 0000 4 5000

62 57 52 47 42 37 32 27 22 17 12 7 2 - 3 OU T S I D E

d e g F 0 1 2 3 4 5

CP* T24-1 VS. AEPT024, AE24XX

0 5 000

1 0 000 1 5 000 2 0 000 2 5 000 3 0 000 3 5 000

62 57 52 47 42 3 7 32 2 7 22 17 12 7 2 - 3 OU T S I D E

d e g F 0 1 2 3 4 5

C P * T 2 4- 1

VS.

U / U C 32 + E E P ,

U / U C 4 2 + EEP,

H 3 6 F + E EP, ARPF036, A RPT032, ARUF032

0 50 00

1 00 00 1 50 00 2 00 00 2 50 00 3 00 00 3 50 00

62 57 5 2 47 4 2 3 7 32 27 2 2 17 1 2 7 2 - 3 OU T S I D E

d e g F 0 1 2 3 4 5

C P * T 3 6 - 1 VS.

U / U C 4 9 + E E P , H 6 0 F + EEP , ARUF048

0 1 000 0 2 000 0 3 000 0 4 000 0 5 000 0 6 000 0

62 5 7 52 47 4 2 37 32 2 7 2 2 17 1 2 7 2 - 3 OU T S I D E

d e g F

0 1 2 3 4 5

C P * T 36 - 1 V S . AEPT036/AE36-XX

0 1 0000 2 0000 3 0000 4 0000 5 0000 6 0000

62 57 52 47 42 37 32 27 22 17 12 7 2 - 3 O U T S I D E

de g F

0 1 2 3 4 5

C P * T 4 2 - 1 VS.

U / U C 6 0 + EEP, H 6 1 F +EEP,

0 10000 20000 30000 40000 50000 60000

62 57 52 47 42 37 32 27 22 17 12 7 2 -3 O U T S I D E

de g F

0 1 2 3 4 5

C P * T 42- 1 V S .

0 1 000 0 2 000 0 3 000 0 4 000 0 5 000 0 6 000 0

6 2 5 7 5 2 4 7 42 37 32 27 22 17 12 7 2 - 3 O U T S I D E de g F

0 1 2 3 4 5

HEA TING BTUH COP

TING

CP * T 3 0 - 1 V AEPT036/AE36 -XX S.

0 5 000 1 0 000 1 5 000 2 0 000 2 5 000 3 0 000 3 5 000 4 0 000 4 5 000

62 57 5 2 47 42 3 7 32 27 22 1 7 12 7 2 - 3 OU T S I D E

d e g F 0 1 2 3 4 5

C P * T 48- 1 V S . U/ U C 61+ E E P ,

H 61F + E E P

0 1 0000 2 0000 3 0000 4 0000 5 0000 6 0000 7 0000

62 57 52 47 42 37 32 27 22 17 12 7 2 -3 O U T S I D E

de g F 0. 0 0 1. 0 0 2. 0 0 3. 0 0 4. 0 0 5. 0 0

C P * T 48 - 1 VS .

0 1 000 0 2 000 0 3 000 0 4 000 0 5 000 0 6 000 0 7 000 0

62 57 5 2 4 7 4 2 37 32 27 22 17 12 7 2 -3 O U T S I D E

de g F

0. 0 0 1. 0 0 2. 0 0 3. 0 0 4. 0 0 5. 0 0

C P * T 48 - 1 V S . A E / /AEPT060

0 1 0 000 2 0 000 3 0 000 4 0 000 5 0 000 6 0 000 7 0 000

62 57 52 47 42 37 32 27 2 2 1 7 1 2 7 2 -3 O U T S I D E

de g F

0. 0 0 1. 0 0 2. 0 0 3. 0 0 4. 0 0 5. 0 0

C P * T 60- 1 V S . U / U C 61+ E E P , H 61F + E E P

0 1 00 00 2 00 00 3 00 00 4 00 00 5 00 00 6 00 00 7 00 00 8 00 00

62 57 5 2 47 42 37 32 27 22 17 12 7 2 - 3 OU T S I D E

de g F 0. 0 0 1. 0 0 2. 0 0 3. 0 0 4. 0 0 5. 0 0

CP * T 6 0 - 1 V S .

0 1 000 0 2 000 0 3 000 0 4 000 0 5 000 0 6 000 0 7 000 0 8 000 0

62 57 5 2 47 42 3 7 32 27 2 2 17 12 7 2 - 3 OU T S I D E

de g F 0. 0 0 1. 0 0 2. 0 0 3. 0 0 4. 0 0 5. 0 0

C P * T 6 0 - 1 VS.

0 1 00 0 0 2 00 0 0 3 00 0 0 4 00 0 0 5 00 0 0 6 00 0 0 7 00 0 0 8 00 0 0

62 5 7 52 4 7 4 2 3 7 32 27 2 2 17 1 2 7 2 - 3 OU T S I D E

d e g F 0. 0 0 1. 0 0 2. 0 0 3. 0 0 4. 0 0 5. 0 0

ARPF036, AR PT032, ARUF032

ARPF048, ARPT049, ARUF049 AEPT048/AE48-XX

A E /AEPT060

ARPF060, ARPT061, ARUF061

ARPF060, ARPT061, ARUF061

Page 8: CPRT SERIES - ELECTROMEC · SS-GCPRT 5 PRODUCT SPECIFICATIONS Performance Ratings 1) Certifi ed per ARI 210/240 @ 80 °F/67 °F/95 °F 2) TVA Rating 3) Seasonal Energy Effi ciency

Goodman Manufacturing Co., L.P., reserves the right to discontinue, or change at any time, specifi cations or designs without notice or without incurring obligations.Copyright © 2005 Goodman Manufacturing Co, L.P. • Houston, Texas Goodman® brand products are made proudly in the USA. Printed in the USA.

8 SS-GCPRT

PRODUCT SPECIFICATIONS