8
SS-340D PRODUCT SPECIFICATIONS www.goodmanmfg.com 8/04 Supercedes 5/04 Split System Heat Pump The CPLJ split system heat pump is designed for ground-level or rooftop mount application. CPLJ SERIES 12 SEER 1½ to 5 Ton Air Handler and Coil Compatibilities • ARUF, ARPT and AEPT multi-position electric heat air handlers • ARPF dedicated downflow electric heat air handler • AWB vertical wall-mounted electric heat air handler • AH vertical wall-mounted hydronic heat air handler • AC ceiling-mounted electric heat air handler • ACHP ceiling-mounted hydronic heat air handler • MBR/MBE modular blower • CA, CH and H indoor coils Accessories • Standard Room Thermostat with 1-stage cool/2- stage heat (HPT18-60) • Digital Room Thermostat with 1-stage cool/2-stage heat (CHTP18-60HD) • Outdoor Lockout Thermostat/Emergency Heat Relay Kit for staging electric heat (OT/EHR18-60) • Outdoor Thermostat (OT18-60); required for all heat pumps if outdoor ambient temperature is 0˚F with 50% or higher relative humidity Standard Features • Energy-efficient compressor with internal high- pressure relief • Louvered guard protects coil from damage and adds strength to unit • Bottom pan rails elevate unit above slab • Quiet operating top discharge • Totally enclosed, permanently lubricated condenser motor • Copper tube, aluminum fin coil • Brass liquid and suction service valves with sweat connections • Fully charged for 15’ of tubing length • Factory-installed bi-flow liquid line filter drier • Discharge line muffler • Suction line accumulator • Check-flowrater expansion device • Time-initiated, temperature-terminate defrost • Low-pressure control for loss of charge protection • Crankcase heater (where indicated) Cabinet Construction • Polyester powder paint provides premium durability and improved UV protection • Heavy-gauge, zinc-clad, G90 galvanized steel • When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds

Upload: others

Post on 08-Dec-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CPLJ SERIES - Alpine Home Air

SS-340D

PRODUCT SPECIFICATIONS

www.goodmanmfg.com 8/04Supercedes 5/04

Split SystemHeat Pump

The CPLJ split system heat pump is designed for ground-level or rooftop mount

application.

CPLJ SERIES12 SEER

1½ to 5 Ton

Air Handler and Coil Compatibilities• ARUF, ARPT and AEPT multi-position electric heat

air handlers• ARPF dedicated downflow electric heat air handler• AWB vertical wall-mounted electric heat air handler• AH vertical wall-mounted hydronic heat air handler• AC ceiling-mounted electric heat air handler• ACHP ceiling-mounted hydronic heat air handler• MBR/MBE modular blower• CA, CH and H indoor coils

Accessories• Standard Room Thermostat with 1-stage cool/2-

stage heat (HPT18-60)• Digital Room Thermostat with 1-stage cool/2-stage

heat (CHTP18-60HD)• Outdoor Lockout Thermostat/Emergency Heat

Relay Kit for staging electric heat (OT/EHR18-60)• Outdoor Thermostat (OT18-60); required for all

heat pumps if outdoor ambient temperature is 0˚F with 50% or higher relative humidity

Standard Features• Energy-efficient compressor with internal high-

pressure relief• Louvered guard protects coil from damage and adds

strength to unit• Bottom pan rails elevate unit above slab• Quiet operating top discharge• Totally enclosed, permanently lubricated

condenser motor• Copper tube, aluminum fin coil• Brass liquid and suction service valves with

sweat connections• Fully charged for 15’ of tubing length• Factory-installed bi-flow liquid line filter drier• Discharge line muffler• Suction line accumulator• Check-flowrater expansion device• Time-initiated, temperature-terminate defrost• Low-pressure control for loss of charge protection• Crankcase heater (where indicated)

Cabinet Construction• Polyester powder paint provides premium durability

and improved UV protection• Heavy-gauge, zinc-clad, G90 galvanized steel• When properly anchored, meets the 2001 Florida

Building Code unit integrity requirements for hurricane-type winds

Page 2: CPLJ SERIES - Alpine Home Air

PRODUCT SPECIFICATIONS

2

Electrical Data

1) Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes2) May use fuses or HACR type Circuit Breakers of the same size as noted3) The -*B models are painted Architectural Gray. All other models are painted Bahama Beige.* With Crankcase Heat**Uses Scroll Compressor

Specifications

ModelService Valve

Type ApproximateShipping Weight (pounds)Liquid Suction

CPLJ18-1A/-1B 3/8” 3/4” Sweat 127CPLJ24-1A/-1B 3/8” 3/4” Sweat 147CPLJ30-1A/-1B 3/8” 3/4” Sweat 142CPLJ36-1A/-1B 3/8” 3/4” Sweat 152 CPLJ42-1A/-1B 3/8” 7/8” Sweat 162CPLJ48-1A/-1B 3/8” 7/8” Sweat 178CPLJ60-1A/-1B 3/8” 7/8” Sweat 182

Model Volts Ph Hz Minimum Circuit Amps1

Maximum Overcurrent Protection2

Minimum Volts

Maximum Volts

Compressor Condenser Fan

RLA LRA FLA HP

*CPLJ18-1A/-1B 208/230 1 60 11.7 20 197 253 8.6 49 .9 1/6*CPLJ24-1A/-1B 208/230 1 60 13.2 20 197 253 9.8 56.0 .9 1/6**CPLJ30-1A/-1B 208/230 1 60 18.0 30 197 253 13.5 72.5 1.1 1/6**CPLJ36-1A/-1B 208/230 1 60 19.3 30 197 253 14.7 83.0 .9 1/6**CPLJ42-1A/-1B 208/230 1 60 24.8 40 197 253 18.4 95.0 1.8 1/4**CPLJ48-1A/-1B 208/230 1 60 24.7 40 197 253 18.3 109.0 1.8 1/4**CPLJ60-1A/-1B 208/230 1 60 33.8 50 197 253 25.0 148.0 2.5 1/3

Page 3: CPLJ SERIES - Alpine Home Air

3

PRODUCT SPECIFICATIONS

Dimensions

ELEVATED CHANNEL

ADDITIONAL 1-1/2“

LIQUID CONN.

SMALL CHASSIS = 23" MEDIUM CHASSIS = 29"

CPLJ24, 30 = 25’’ CPLJ18 = 32.5’’

CPLJ42 = 37.5’’ CPLJ48, 60 = 40’’

7/8" DIA. CONTROL

CPLJ36 = 30’’

1-1/8" DIA. POWER

SUCTION CONN.

SMALL CHASSIS = 23’’ MEDIUM CHASSIS = 29’’

SMALL CHASSIS

MEDIUM CHASSIS

Page 4: CPLJ SERIES - Alpine Home Air

PRODUCT SPECIFICATIONS

4

Performance Ratings

Model Evaporator CoilTotal

Cooling BTUH1

Sensible Cooling BTUH

BTUH @75 ºF/63 ºF to 95 ºF2 Cooling

SEER3Cooling

EER4

Heating BTUH @

47°F

HeatingCOP @ 47ºF

Heating BTUH @

17ºF

Heating COP @17ºF

Heating HSPF5 Decibels

Total Sensible

CPLJ18-1A/-1B

AC18-XXAC24-XXARUF018AWB18-XXAWB24-XX

U/UC32+EEP6

HT3236/H36F+EEPARPF036/ARPT032/ARUF032

AEPT030CA*F030*2*+EEPCHPF030A2*+EEP

16,40016,80017,00017,00017,40018,00018,00018,00018,00018,00018,000

12,30012,60012,70012,70013,10014,20014,20014,20014,20014,20014,200

15,50015,80016,00016,00016,40017,00017,00017,00017,00017,00017,000

11,80012,00012,20012,20012,60013,70013,70013,70013,70013,70013,700

11.5012.0011.0011.0012.0012.0012.0012.0013.0012.0012.00

10.5011.0010.0010.0011.0011.0011.0011.0012.0011.0011.00

16,00016,40017,00017,00017,40018,00018,00018,00018,00018,00018,000

2.803.003.003.003.003.503.503.503.503.503.50

9,0009,4009,4009,4009,60010,00010,00010,00010,00010,00010,000

2.002.002.002.002.002.202.202.202.202.202.20

7.007.007.007.007.507.307.307.507.807.307.30

72

CPLJ24-1A/-1B

AC24-XXAC30-XX

AWB24-XXARPT024/ARUF024

U/UC32+EEPU/UC42+EEP

HT3236/H36F+EEPAWB36-XX

ARPF036/ARPT032/ARUF032ARPT042/ARUF042

AEPT030CA*F030*2*+EEPCA*F042*2*+EEPCHPF030A2*+EEP

21,20022,00022,40022,40023,00023,00023,00023,00023,00023,00023,00023,00023,00023,000

15,90016,50016,80016,80018,00018,00018,00018,00018,00018,00018,00018,00018,00018,000

20,00020,70021,10021,10021,70021,70021,70021,70021,70021,70021,70021,70021,70021,700

15,50016,00016,40016,40017,40017,40017,40017,40017,40017,40017,40017,40017,40017,400

11.5012.0011.5011.5012.0012.0012.0012.0012.0012.0013.0012.0012.0012.00

10.5011.0010.5010.5011.0011.0011.0011.0011.0011.0012.0011.0011.0011.00

20,20021,00022,00022,00023,00023,00023,00023,00023,00023,00023,00023,00023,00023,000

2.802.803.003.003.303.303.303.303.303.303.303.303.303.30

11,80012,00012,10012,10013,60013,60013,60013,60013,60013,60013,60013,60013,60013,600

2.002.202.202.202.602.602.602.602.602.602.602.602.602.60

7.007.007.007.007.507.507.507.507.807.808.107.507.507.50

73

CPLJ30-1A/-1B

AC30-XXAC36-XX

AWB30-XXARUF030

HT3236/U/UC32+EEPU/UC42+EEP

HT4248/H36F+EEPAWB36-XX

ARPF036/ARPT032/ARUF032ARPT042/ARUF042

AEPT030AEPT036

CA*F030*2*+EEPCA*F042*2*+EEPCHPF030A2*+EEPCHPF042B2*+EEP

27,00027,40027,20027,20029,00029,00029,00029,00029,00029,00029,00030,00029,00029,00029,00029,000

20,20020,50020,40020,40021,60021,60021,60021,60021,60021,60021,60022,30021,60021,60021,60021,600

24,60025,00024,80024,80027,40027,40027,40027,40027,40027,40026,80029,30027,40027,40027,40027,400

18,90019,10019,10019,10020,70020,70020,70020,70020,70020,70021,20019,00020,70020,70020,70020,700

11.5012.0011.3011.3012.0012.0012.0012.0012.0012.0012.5013.0012.0012.0012.0012.00

10.5011.0010.5010.5011.0011.0011.0011.0011.0011.0011.5012.0011.0011.0011.0011.00

26,00026,40027,00027,00029,40029,40029,40029,40029,40029,40029,40030,00029,40029,40029,40029,400

2.802.803.003.003.303.303.303.303.303.303.303.503.303.303.303.30

14,00014,60014,80014,60017,00017,00017,00017,00017,00017,00017,00018,00017,00017,00017,00017,000

2.202.202.202.202.402.402.402.402.402.402.402.402.402.402.402.40

7.007.007.007.007.507.507.507.507.507.507.807.807.507.507.507.50

80

1) Certified per ARI 240 @ 80 °F/67 °F/95 °F2) TVA Rating3) Seasonal Energy Efficiency Ratio4) Energy Efficiency Ratio @ 80 °F/67 °F/95 °F5) HSPF = Heating Seasonal Performance Factor6) Order the EEP from the Service Department using Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not

interchangeable with B13707-35S.When mix-matching outdoor and indoor units, the indoor unit check-flowrator must match the outdoor unit size.See the AR series air handler for coil instructions.

Page 5: CPLJ SERIES - Alpine Home Air

5

PRODUCT SPECIFICATIONS

Model Evaporator CoilTotal

Cooling BTUH1

Sensible Cooling BTUH

BTUH @75 ºF/63 ºF to 95 ºF2 Cooling

SEER3Cooling

EER4

Heating BTUH @

47°F

HeatingCOP @ 47ºF

Heating BTUH @

17ºF

Heating COP @17ºF

Heating HSPF5 Decibels

Total Sensible

CPLJ36-1A/-1B

AC36-XXAWB36-XX/ARPT036/ARUF036

U/UC42+EEP6

HT4248/H49F+EEPARPT042/ARUF042

AEPT036ARPF048

CA*F042*2*+EEPCHPF042B2*+EEP

32,00033,00034,00034,00034,00035,00035,00034,00034,000

23,00023,80024,50024,50024,50025,90025,90024,50024,500

30,20031,15032,10032,10032,10034,00034,00032,10032,100

24,00024,90023,30023,30023,30024,60024,60023,30023,300

11.0011.3012.0012.0012.0013.0012.0012.0012.00

10.0010.3011.0011.0011.0012.0011.0011.0011.00

31,00033,00035,00035,00035,00035,00035,00035,00035,000

2.803.203.503.503.503.503.503.503.50

17,00019,00020,00020,00020,00020,00020,00020,00020,000

2.002.102.302.302.302.302.302.302.30

7.007.507.807.807.808.007.807.807.80

80

CPLJ42-1A/-1B

ARPT042/ARUF042U/UC60+EEP

HT61/H61F+EEPARPF048/ARPT049/ARUF049

AEPT060-00A-1CA*F060*2*+EEPCHPF060D2*+EEP

38,50040,00040,00040,00041,00040,00040,000

27,60030,40030,40030,40031,00030,40030,400

36,20037,80037,80037,80037,80037,80037,800

29,30029,30029,00029,30029,90029,30029,300

11.3012.0012.0012.0013.0012.0012.00

10.3011.0011.0011.0012.0011.0011.00

38,50040,00040,00040,00040,00040,00040,000

3.303.503.503.503.503.503.50

21,00022,40022,40022,40023,00022,40022,400

2.102.302.302.302.302.302.30

7.508.008.008.008.308.008.00

80

CPLJ48-1A/-1B

ARUF048ARPT049/ARUF049

U/UC60+EEPHT61/H61F+EEP

AEPT060ARPF060/ARPT061/ARUF061

CA*F060*2*+EEPCHPF060D2*+EEP

44,00044,00044,00044,00046,00046,00044,00044,000

32,50032,50032,50032,50035,00035,00032,50032,500

41,50041,50041,50041,50043,40043,40041,50041,500

31,00031,00031,00031,00033,60033,60031,00031,000

11.5012.0012.0012.0012.5012.0012.0012.00

10.5011.0011.0011.0011.5011.0011.0011.00

44,00045,00045,00045,00046,00046,00045,00045,000

3.303.503.503.503.603.603.503.50

24,00025,00025,00025,00027,00027,00025,00025,000

2.202.302.302.302.402.402.302.30

7.508.008.008.008.508.008.008.00

80

CPLJ60-1A/-1B

ARUF060U/UC62+EEP

ARPF060/ARPT061/ARUF061HT61/U/UC61+EEP

H61F+EEPAEPT060

CA*F061*2*+EEPCHPF060D2*+EEP

55,00055,00056,00056,00056,00056,00056,00056,000

39,60039,60040,30040,30040,30040,30040,30040,300

51,90051,90052,60052,60052,60052,60052,60052,600

37,00037,00037,70037,70037,70037,70037,70037,700

11.3011.5012.0012.0012.0012.0012.0012.00

10.3010.5011.0011.0011.0011.0011.0011.00

55,00055,00056,00056,00056,00056,00056,00056,000

3.203.203.303.303.303.303.303.30

30,00030,00031,00031,00031,00031,00031,00031,000

2.102.102.302.302.302.302.302.30

7.507.508.008.008.008.508.008.00

80

Performance Ratings (cont.)

1) Certified per ARI 240 @ 80 °F/67 °F/95 °F2) TVA Rating3) Seasonal Energy Efficiency Ratio4) Energy Efficiency Ratio @ 80 °F/67 °F/95 °F5) HSPF = Heating Seasonal Performance Factor6) Order the EEP from the Service Department using Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not

interchangeable with B13707-35S.When mix-matching outdoor and indoor units, the indoor unit check-flowrator must match the outdoor unit size.

Page 6: CPLJ SERIES - Alpine Home Air

PRODUCT SPECIFICATIONS

6

Heating Performance Expanded Ratings @ 70 °F Indoor Ambient

Page 7: CPLJ SERIES - Alpine Home Air

7

PRODUCT SPECIFICATIONS

Heating Performance Expanded Ratings @ 70 °F Indoor Ambient (cont.)

Page 8: CPLJ SERIES - Alpine Home Air

PRODUCT SPECIFICATIONS

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.Copyright © 2004 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. • Goodman® brand products are made proudly in the USA.