cover 6 & 14 cladding · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and...
TRANSCRIPT
COVER 6 amp 14 CLADDINGChannel cladding with high fire resistance up to B-s3d0 and invisible fixing
for ventilated facades with or without external thermal insulation
TECHNICAL DATA SHEETref BFFT 092018-011-EN
PRODUCT ADVANTAGES
2
DESIGN amp ENVIRONMENTAL FRIENDLY
LENGTHS AND PROFILES
325 m long and 30 cm wide board 1 sqm per board
4 ribs of 6 cm (COVER 6) 2 ribs of 14 cm (COVER 14) Shadow line width 1 cm
Shadow line depth 2 cm Possible combination of all boards
AESTHETIC The striated surface enhances the light with a change of intensity
throughout the day
Marked slatted look with regular grooving
Invisible fixing
Only 6mm expansion joint at the end of the board
NATURAL Made of VESTAreg a unique Mineral Reinforced Wood Fiber
Contains 75 wood fibres sourced from sustainably managed European
forests
Does not contain any toxic products adhesives coupling agents or heavy
metals
100 French design amp production
Environmental Product Declaration issued by VERITAS
Environmental assessment issued by the Swiss Eco-Bau laboratory
suitable for green building projects (like MINERGIE BREEAM LEED)
Cover 14 2 ribs of 14 cm
Cover 6 4 ribs of 6 cm
RESISTANCE
ACCREDITED Product approval certificates issued by the French
building office (CSTB)
STABLE AND ROT-PROOF
Exceptional dimensional stability with only 15mm
expansion per linear meter over 50degC temperature
variation or 2mmm over 80degC equal to aluminium
Rot-proof does not absorb humidity
100 insect-resistant (including termites)
Stability to UVs stabilisation on the mineral
pigmentrsquos colour
Graffiti and scratches can be easily brushed out or
cleaned off
RATINGS
FIRE REACTION COVER 6 Class B-s3 d0 (EN 13501-12007)
COVER 14
Horizontal installation Class B-s3 d0 (EN 13501-12007)
Vertical installation on metal framework Class B s3 d0 (EN 13501-12007)
on wooden framework Class C s3 d0 (EN 13501-12007)
IMPACT TEST No damages after hard and soft body impact
max impact energy 50kg-130J 3kg-20J 1kg 3J
SEISMIC TEST Highest seismic behaviour following EN 1998 amp Eurocode 8 no risk of falling
boards after static and or dynamic test
WIND LOAD Up to max 237 kN sqm shearing pressure following EN 1991 1-4
with 400mm batten spacing
THERMAL CONDUCTIVITY Low conductivity Lambda von 007 Wmk
Thermal conductivity lower than natural wood
EASY TO INSTALL
FAST amp ACCURATE IMPLEMENTATION
Can be fitted vertically or horizontally on wood or metal
structure
Wide boards of 1sqm for a fast implementation
Fast installation on ventilated batten structure with a 40 to
60cm distance
Interlocking of the boards for guaranteed regular amp parallel
grooves
Fixing by invisible steel hooks screwed into the wood
or metal structures
CORNERS AND DETAILS
Horizontal fitting 45deg mitre-cut for perfect regular corners or
aluminium corner profile with adapted RAL colour
Vertical fitting and soffits aluminium corner profile with
adapted RAL colour
NATURAL COLOURS
Due to the inherent disparities in the standardisation of screens and printing inks the shades depicted onthis sheet may appear slightly different to those of the actual samples
EarthRAL 8019
OceanRAL 7046
SandRAL 1019
HeatRAL 8017
NightRAL 9004
RAL EQUIVALENCESAbove mentioned RAL colours are matching the best to VESTAreg eco-materialrsquos tint but can not be
considered as exactly similar The given indications are informative the responsibility lies with the
customer to determine whether the RAL color fits to its project or doesnrsquot
SunRAL 1011
SIX NATURAL COLOURS TINTED THROUGHOUT WITH MINERAL PIGMENTS(Informative RAL colours for accessories)
AGEING
bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour
bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end
colourbull Final patina will be achieved within 10 weeks in average
BOARDS AGEING PROCESS
The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint
NIG
HT
OC
EacuteAN
SAN
DSU
NH
EAT
Day 1 Installation After 10 weeks
EAR
TH
PROFILES amp ACCESSORIES
References Products Profiles Dimension
BF4O325O5 Cover 6 - 4 waves Ocean
BF4O325H5 Cover 6 - 4 waves Heat
BF4O325S5 Cover 6 - 4 waves Sand
BF4O325U5 Cover 6 - 4 waves Sun
BF4O325N5 Cover 6 - 4 waves Night
BF4O325E5 Cover 6 - 4 waves Earth
BF2O325O5 Cover 14 - 2 waves Ocean
BF2O325H5 Cover 14 - 2 waves Heat
BF2O325S5 Cover 14 - 2 waves Sand
BF2O325U5 Cover 14 - 2 waves Sun
BF2O325N5 Cover 14 - 2 waves Night
BF2O325E5 Cover 14 - 2 waves Earth
CORNER PROFILEReferences Products Profiles Dimension
BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean
BAPA300H1 Aluminium Corner - pack of 2 pcs Heat
BAPA300S1 Aluminium Corner - pack of 2 pcs Sand
BAPA300U1 Aluminium Corner - pack of 2 pcs Sun
BAPA300N1 Aluminium Corner - pack of 2 pcs Night
BAPA300E1 Aluminium Corner - pack of 2 pcs Earth
PIERCED STARTING PROFILEReferences Products Profiles Dimension
BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness
300 x 43 x 4 cm(L x W x H)
Colours
COVER 6 amp COVER 14Colours
Colours
Neutral
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
300 x 6 x 6 cm(L x W x H)
FIXINGS
Number of hooks msup2 COVER 614
60 cm centre-to-centre spacing 10 msup2
40 cm 60 cm centre-to-centre spacing 15 msup2
FIXING HOOKSReferences Products Profiles Dimension
BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)
A2 STAINLESS STEEL SCREWReferences
VIS BA RAL ndeg
VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Colours
Products colours
RAL color
RAL color
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
VIS INOX A2 - A2 STAINLESS STEEL SCREW
VIS BA NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
VIS ME NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
Reference Profiles Dimcm Weight in kgProduct
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
4kg
4kg
INSTALLATIONKEY PRINCIPLES
10
IMPLEMENTATION ON EXTERNAL THERMAL INSULATION
Horizontal fitting
Vertical fitting
TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS
Timber frame wall
Concrete wall
Timber frame wall
Concrete wall
Insulation
Insulation
IMPORTANT
Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm
Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight
This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation
In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)
IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)
Horinzontal fitting
IMPORTANT
Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm
Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height
This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation
In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)
Steelstructure
Liner trays
Vertical fitting
Insulation
Insulation
Steelstructure
Liner trays
REMARQUES IMPORTANTES SUR LA POSE
BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)
Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)
Thickness 285 mm (tolerance of plusmn 115 mm)
Squaring has to be done on site
Boards have to be calibrated according to layout
START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the
boards in the same orientation in order to obtain a uniform colour Indeed the random brushing
creates an effect on the surface that capture the lights differently according the boards orientation
Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top
IMPORTANT NOTICES
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
Groove at the bottom
Horizontal intallation
Tongue at the top
Verticalinstallation
Profil alu de deacutepart visseacute
Screwed aluminium starting profile
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
PRODUCT ADVANTAGES
2
DESIGN amp ENVIRONMENTAL FRIENDLY
LENGTHS AND PROFILES
325 m long and 30 cm wide board 1 sqm per board
4 ribs of 6 cm (COVER 6) 2 ribs of 14 cm (COVER 14) Shadow line width 1 cm
Shadow line depth 2 cm Possible combination of all boards
AESTHETIC The striated surface enhances the light with a change of intensity
throughout the day
Marked slatted look with regular grooving
Invisible fixing
Only 6mm expansion joint at the end of the board
NATURAL Made of VESTAreg a unique Mineral Reinforced Wood Fiber
Contains 75 wood fibres sourced from sustainably managed European
forests
Does not contain any toxic products adhesives coupling agents or heavy
metals
100 French design amp production
Environmental Product Declaration issued by VERITAS
Environmental assessment issued by the Swiss Eco-Bau laboratory
suitable for green building projects (like MINERGIE BREEAM LEED)
Cover 14 2 ribs of 14 cm
Cover 6 4 ribs of 6 cm
RESISTANCE
ACCREDITED Product approval certificates issued by the French
building office (CSTB)
STABLE AND ROT-PROOF
Exceptional dimensional stability with only 15mm
expansion per linear meter over 50degC temperature
variation or 2mmm over 80degC equal to aluminium
Rot-proof does not absorb humidity
100 insect-resistant (including termites)
Stability to UVs stabilisation on the mineral
pigmentrsquos colour
Graffiti and scratches can be easily brushed out or
cleaned off
RATINGS
FIRE REACTION COVER 6 Class B-s3 d0 (EN 13501-12007)
COVER 14
Horizontal installation Class B-s3 d0 (EN 13501-12007)
Vertical installation on metal framework Class B s3 d0 (EN 13501-12007)
on wooden framework Class C s3 d0 (EN 13501-12007)
IMPACT TEST No damages after hard and soft body impact
max impact energy 50kg-130J 3kg-20J 1kg 3J
SEISMIC TEST Highest seismic behaviour following EN 1998 amp Eurocode 8 no risk of falling
boards after static and or dynamic test
WIND LOAD Up to max 237 kN sqm shearing pressure following EN 1991 1-4
with 400mm batten spacing
THERMAL CONDUCTIVITY Low conductivity Lambda von 007 Wmk
Thermal conductivity lower than natural wood
EASY TO INSTALL
FAST amp ACCURATE IMPLEMENTATION
Can be fitted vertically or horizontally on wood or metal
structure
Wide boards of 1sqm for a fast implementation
Fast installation on ventilated batten structure with a 40 to
60cm distance
Interlocking of the boards for guaranteed regular amp parallel
grooves
Fixing by invisible steel hooks screwed into the wood
or metal structures
CORNERS AND DETAILS
Horizontal fitting 45deg mitre-cut for perfect regular corners or
aluminium corner profile with adapted RAL colour
Vertical fitting and soffits aluminium corner profile with
adapted RAL colour
NATURAL COLOURS
Due to the inherent disparities in the standardisation of screens and printing inks the shades depicted onthis sheet may appear slightly different to those of the actual samples
EarthRAL 8019
OceanRAL 7046
SandRAL 1019
HeatRAL 8017
NightRAL 9004
RAL EQUIVALENCESAbove mentioned RAL colours are matching the best to VESTAreg eco-materialrsquos tint but can not be
considered as exactly similar The given indications are informative the responsibility lies with the
customer to determine whether the RAL color fits to its project or doesnrsquot
SunRAL 1011
SIX NATURAL COLOURS TINTED THROUGHOUT WITH MINERAL PIGMENTS(Informative RAL colours for accessories)
AGEING
bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour
bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end
colourbull Final patina will be achieved within 10 weeks in average
BOARDS AGEING PROCESS
The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint
NIG
HT
OC
EacuteAN
SAN
DSU
NH
EAT
Day 1 Installation After 10 weeks
EAR
TH
PROFILES amp ACCESSORIES
References Products Profiles Dimension
BF4O325O5 Cover 6 - 4 waves Ocean
BF4O325H5 Cover 6 - 4 waves Heat
BF4O325S5 Cover 6 - 4 waves Sand
BF4O325U5 Cover 6 - 4 waves Sun
BF4O325N5 Cover 6 - 4 waves Night
BF4O325E5 Cover 6 - 4 waves Earth
BF2O325O5 Cover 14 - 2 waves Ocean
BF2O325H5 Cover 14 - 2 waves Heat
BF2O325S5 Cover 14 - 2 waves Sand
BF2O325U5 Cover 14 - 2 waves Sun
BF2O325N5 Cover 14 - 2 waves Night
BF2O325E5 Cover 14 - 2 waves Earth
CORNER PROFILEReferences Products Profiles Dimension
BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean
BAPA300H1 Aluminium Corner - pack of 2 pcs Heat
BAPA300S1 Aluminium Corner - pack of 2 pcs Sand
BAPA300U1 Aluminium Corner - pack of 2 pcs Sun
BAPA300N1 Aluminium Corner - pack of 2 pcs Night
BAPA300E1 Aluminium Corner - pack of 2 pcs Earth
PIERCED STARTING PROFILEReferences Products Profiles Dimension
BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness
300 x 43 x 4 cm(L x W x H)
Colours
COVER 6 amp COVER 14Colours
Colours
Neutral
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
300 x 6 x 6 cm(L x W x H)
FIXINGS
Number of hooks msup2 COVER 614
60 cm centre-to-centre spacing 10 msup2
40 cm 60 cm centre-to-centre spacing 15 msup2
FIXING HOOKSReferences Products Profiles Dimension
BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)
A2 STAINLESS STEEL SCREWReferences
VIS BA RAL ndeg
VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Colours
Products colours
RAL color
RAL color
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
VIS INOX A2 - A2 STAINLESS STEEL SCREW
VIS BA NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
VIS ME NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
Reference Profiles Dimcm Weight in kgProduct
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
4kg
4kg
INSTALLATIONKEY PRINCIPLES
10
IMPLEMENTATION ON EXTERNAL THERMAL INSULATION
Horizontal fitting
Vertical fitting
TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS
Timber frame wall
Concrete wall
Timber frame wall
Concrete wall
Insulation
Insulation
IMPORTANT
Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm
Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight
This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation
In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)
IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)
Horinzontal fitting
IMPORTANT
Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm
Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height
This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation
In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)
Steelstructure
Liner trays
Vertical fitting
Insulation
Insulation
Steelstructure
Liner trays
REMARQUES IMPORTANTES SUR LA POSE
BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)
Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)
Thickness 285 mm (tolerance of plusmn 115 mm)
Squaring has to be done on site
Boards have to be calibrated according to layout
START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the
boards in the same orientation in order to obtain a uniform colour Indeed the random brushing
creates an effect on the surface that capture the lights differently according the boards orientation
Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top
IMPORTANT NOTICES
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
Groove at the bottom
Horizontal intallation
Tongue at the top
Verticalinstallation
Profil alu de deacutepart visseacute
Screwed aluminium starting profile
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
DESIGN amp ENVIRONMENTAL FRIENDLY
LENGTHS AND PROFILES
325 m long and 30 cm wide board 1 sqm per board
4 ribs of 6 cm (COVER 6) 2 ribs of 14 cm (COVER 14) Shadow line width 1 cm
Shadow line depth 2 cm Possible combination of all boards
AESTHETIC The striated surface enhances the light with a change of intensity
throughout the day
Marked slatted look with regular grooving
Invisible fixing
Only 6mm expansion joint at the end of the board
NATURAL Made of VESTAreg a unique Mineral Reinforced Wood Fiber
Contains 75 wood fibres sourced from sustainably managed European
forests
Does not contain any toxic products adhesives coupling agents or heavy
metals
100 French design amp production
Environmental Product Declaration issued by VERITAS
Environmental assessment issued by the Swiss Eco-Bau laboratory
suitable for green building projects (like MINERGIE BREEAM LEED)
Cover 14 2 ribs of 14 cm
Cover 6 4 ribs of 6 cm
RESISTANCE
ACCREDITED Product approval certificates issued by the French
building office (CSTB)
STABLE AND ROT-PROOF
Exceptional dimensional stability with only 15mm
expansion per linear meter over 50degC temperature
variation or 2mmm over 80degC equal to aluminium
Rot-proof does not absorb humidity
100 insect-resistant (including termites)
Stability to UVs stabilisation on the mineral
pigmentrsquos colour
Graffiti and scratches can be easily brushed out or
cleaned off
RATINGS
FIRE REACTION COVER 6 Class B-s3 d0 (EN 13501-12007)
COVER 14
Horizontal installation Class B-s3 d0 (EN 13501-12007)
Vertical installation on metal framework Class B s3 d0 (EN 13501-12007)
on wooden framework Class C s3 d0 (EN 13501-12007)
IMPACT TEST No damages after hard and soft body impact
max impact energy 50kg-130J 3kg-20J 1kg 3J
SEISMIC TEST Highest seismic behaviour following EN 1998 amp Eurocode 8 no risk of falling
boards after static and or dynamic test
WIND LOAD Up to max 237 kN sqm shearing pressure following EN 1991 1-4
with 400mm batten spacing
THERMAL CONDUCTIVITY Low conductivity Lambda von 007 Wmk
Thermal conductivity lower than natural wood
EASY TO INSTALL
FAST amp ACCURATE IMPLEMENTATION
Can be fitted vertically or horizontally on wood or metal
structure
Wide boards of 1sqm for a fast implementation
Fast installation on ventilated batten structure with a 40 to
60cm distance
Interlocking of the boards for guaranteed regular amp parallel
grooves
Fixing by invisible steel hooks screwed into the wood
or metal structures
CORNERS AND DETAILS
Horizontal fitting 45deg mitre-cut for perfect regular corners or
aluminium corner profile with adapted RAL colour
Vertical fitting and soffits aluminium corner profile with
adapted RAL colour
NATURAL COLOURS
Due to the inherent disparities in the standardisation of screens and printing inks the shades depicted onthis sheet may appear slightly different to those of the actual samples
EarthRAL 8019
OceanRAL 7046
SandRAL 1019
HeatRAL 8017
NightRAL 9004
RAL EQUIVALENCESAbove mentioned RAL colours are matching the best to VESTAreg eco-materialrsquos tint but can not be
considered as exactly similar The given indications are informative the responsibility lies with the
customer to determine whether the RAL color fits to its project or doesnrsquot
SunRAL 1011
SIX NATURAL COLOURS TINTED THROUGHOUT WITH MINERAL PIGMENTS(Informative RAL colours for accessories)
AGEING
bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour
bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end
colourbull Final patina will be achieved within 10 weeks in average
BOARDS AGEING PROCESS
The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint
NIG
HT
OC
EacuteAN
SAN
DSU
NH
EAT
Day 1 Installation After 10 weeks
EAR
TH
PROFILES amp ACCESSORIES
References Products Profiles Dimension
BF4O325O5 Cover 6 - 4 waves Ocean
BF4O325H5 Cover 6 - 4 waves Heat
BF4O325S5 Cover 6 - 4 waves Sand
BF4O325U5 Cover 6 - 4 waves Sun
BF4O325N5 Cover 6 - 4 waves Night
BF4O325E5 Cover 6 - 4 waves Earth
BF2O325O5 Cover 14 - 2 waves Ocean
BF2O325H5 Cover 14 - 2 waves Heat
BF2O325S5 Cover 14 - 2 waves Sand
BF2O325U5 Cover 14 - 2 waves Sun
BF2O325N5 Cover 14 - 2 waves Night
BF2O325E5 Cover 14 - 2 waves Earth
CORNER PROFILEReferences Products Profiles Dimension
BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean
BAPA300H1 Aluminium Corner - pack of 2 pcs Heat
BAPA300S1 Aluminium Corner - pack of 2 pcs Sand
BAPA300U1 Aluminium Corner - pack of 2 pcs Sun
BAPA300N1 Aluminium Corner - pack of 2 pcs Night
BAPA300E1 Aluminium Corner - pack of 2 pcs Earth
PIERCED STARTING PROFILEReferences Products Profiles Dimension
BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness
300 x 43 x 4 cm(L x W x H)
Colours
COVER 6 amp COVER 14Colours
Colours
Neutral
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
300 x 6 x 6 cm(L x W x H)
FIXINGS
Number of hooks msup2 COVER 614
60 cm centre-to-centre spacing 10 msup2
40 cm 60 cm centre-to-centre spacing 15 msup2
FIXING HOOKSReferences Products Profiles Dimension
BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)
A2 STAINLESS STEEL SCREWReferences
VIS BA RAL ndeg
VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Colours
Products colours
RAL color
RAL color
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
VIS INOX A2 - A2 STAINLESS STEEL SCREW
VIS BA NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
VIS ME NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
Reference Profiles Dimcm Weight in kgProduct
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
4kg
4kg
INSTALLATIONKEY PRINCIPLES
10
IMPLEMENTATION ON EXTERNAL THERMAL INSULATION
Horizontal fitting
Vertical fitting
TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS
Timber frame wall
Concrete wall
Timber frame wall
Concrete wall
Insulation
Insulation
IMPORTANT
Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm
Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight
This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation
In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)
IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)
Horinzontal fitting
IMPORTANT
Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm
Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height
This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation
In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)
Steelstructure
Liner trays
Vertical fitting
Insulation
Insulation
Steelstructure
Liner trays
REMARQUES IMPORTANTES SUR LA POSE
BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)
Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)
Thickness 285 mm (tolerance of plusmn 115 mm)
Squaring has to be done on site
Boards have to be calibrated according to layout
START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the
boards in the same orientation in order to obtain a uniform colour Indeed the random brushing
creates an effect on the surface that capture the lights differently according the boards orientation
Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top
IMPORTANT NOTICES
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
Groove at the bottom
Horizontal intallation
Tongue at the top
Verticalinstallation
Profil alu de deacutepart visseacute
Screwed aluminium starting profile
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
RESISTANCE
ACCREDITED Product approval certificates issued by the French
building office (CSTB)
STABLE AND ROT-PROOF
Exceptional dimensional stability with only 15mm
expansion per linear meter over 50degC temperature
variation or 2mmm over 80degC equal to aluminium
Rot-proof does not absorb humidity
100 insect-resistant (including termites)
Stability to UVs stabilisation on the mineral
pigmentrsquos colour
Graffiti and scratches can be easily brushed out or
cleaned off
RATINGS
FIRE REACTION COVER 6 Class B-s3 d0 (EN 13501-12007)
COVER 14
Horizontal installation Class B-s3 d0 (EN 13501-12007)
Vertical installation on metal framework Class B s3 d0 (EN 13501-12007)
on wooden framework Class C s3 d0 (EN 13501-12007)
IMPACT TEST No damages after hard and soft body impact
max impact energy 50kg-130J 3kg-20J 1kg 3J
SEISMIC TEST Highest seismic behaviour following EN 1998 amp Eurocode 8 no risk of falling
boards after static and or dynamic test
WIND LOAD Up to max 237 kN sqm shearing pressure following EN 1991 1-4
with 400mm batten spacing
THERMAL CONDUCTIVITY Low conductivity Lambda von 007 Wmk
Thermal conductivity lower than natural wood
EASY TO INSTALL
FAST amp ACCURATE IMPLEMENTATION
Can be fitted vertically or horizontally on wood or metal
structure
Wide boards of 1sqm for a fast implementation
Fast installation on ventilated batten structure with a 40 to
60cm distance
Interlocking of the boards for guaranteed regular amp parallel
grooves
Fixing by invisible steel hooks screwed into the wood
or metal structures
CORNERS AND DETAILS
Horizontal fitting 45deg mitre-cut for perfect regular corners or
aluminium corner profile with adapted RAL colour
Vertical fitting and soffits aluminium corner profile with
adapted RAL colour
NATURAL COLOURS
Due to the inherent disparities in the standardisation of screens and printing inks the shades depicted onthis sheet may appear slightly different to those of the actual samples
EarthRAL 8019
OceanRAL 7046
SandRAL 1019
HeatRAL 8017
NightRAL 9004
RAL EQUIVALENCESAbove mentioned RAL colours are matching the best to VESTAreg eco-materialrsquos tint but can not be
considered as exactly similar The given indications are informative the responsibility lies with the
customer to determine whether the RAL color fits to its project or doesnrsquot
SunRAL 1011
SIX NATURAL COLOURS TINTED THROUGHOUT WITH MINERAL PIGMENTS(Informative RAL colours for accessories)
AGEING
bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour
bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end
colourbull Final patina will be achieved within 10 weeks in average
BOARDS AGEING PROCESS
The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint
NIG
HT
OC
EacuteAN
SAN
DSU
NH
EAT
Day 1 Installation After 10 weeks
EAR
TH
PROFILES amp ACCESSORIES
References Products Profiles Dimension
BF4O325O5 Cover 6 - 4 waves Ocean
BF4O325H5 Cover 6 - 4 waves Heat
BF4O325S5 Cover 6 - 4 waves Sand
BF4O325U5 Cover 6 - 4 waves Sun
BF4O325N5 Cover 6 - 4 waves Night
BF4O325E5 Cover 6 - 4 waves Earth
BF2O325O5 Cover 14 - 2 waves Ocean
BF2O325H5 Cover 14 - 2 waves Heat
BF2O325S5 Cover 14 - 2 waves Sand
BF2O325U5 Cover 14 - 2 waves Sun
BF2O325N5 Cover 14 - 2 waves Night
BF2O325E5 Cover 14 - 2 waves Earth
CORNER PROFILEReferences Products Profiles Dimension
BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean
BAPA300H1 Aluminium Corner - pack of 2 pcs Heat
BAPA300S1 Aluminium Corner - pack of 2 pcs Sand
BAPA300U1 Aluminium Corner - pack of 2 pcs Sun
BAPA300N1 Aluminium Corner - pack of 2 pcs Night
BAPA300E1 Aluminium Corner - pack of 2 pcs Earth
PIERCED STARTING PROFILEReferences Products Profiles Dimension
BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness
300 x 43 x 4 cm(L x W x H)
Colours
COVER 6 amp COVER 14Colours
Colours
Neutral
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
300 x 6 x 6 cm(L x W x H)
FIXINGS
Number of hooks msup2 COVER 614
60 cm centre-to-centre spacing 10 msup2
40 cm 60 cm centre-to-centre spacing 15 msup2
FIXING HOOKSReferences Products Profiles Dimension
BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)
A2 STAINLESS STEEL SCREWReferences
VIS BA RAL ndeg
VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Colours
Products colours
RAL color
RAL color
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
VIS INOX A2 - A2 STAINLESS STEEL SCREW
VIS BA NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
VIS ME NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
Reference Profiles Dimcm Weight in kgProduct
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
4kg
4kg
INSTALLATIONKEY PRINCIPLES
10
IMPLEMENTATION ON EXTERNAL THERMAL INSULATION
Horizontal fitting
Vertical fitting
TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS
Timber frame wall
Concrete wall
Timber frame wall
Concrete wall
Insulation
Insulation
IMPORTANT
Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm
Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight
This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation
In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)
IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)
Horinzontal fitting
IMPORTANT
Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm
Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height
This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation
In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)
Steelstructure
Liner trays
Vertical fitting
Insulation
Insulation
Steelstructure
Liner trays
REMARQUES IMPORTANTES SUR LA POSE
BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)
Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)
Thickness 285 mm (tolerance of plusmn 115 mm)
Squaring has to be done on site
Boards have to be calibrated according to layout
START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the
boards in the same orientation in order to obtain a uniform colour Indeed the random brushing
creates an effect on the surface that capture the lights differently according the boards orientation
Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top
IMPORTANT NOTICES
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
Groove at the bottom
Horizontal intallation
Tongue at the top
Verticalinstallation
Profil alu de deacutepart visseacute
Screwed aluminium starting profile
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
EASY TO INSTALL
FAST amp ACCURATE IMPLEMENTATION
Can be fitted vertically or horizontally on wood or metal
structure
Wide boards of 1sqm for a fast implementation
Fast installation on ventilated batten structure with a 40 to
60cm distance
Interlocking of the boards for guaranteed regular amp parallel
grooves
Fixing by invisible steel hooks screwed into the wood
or metal structures
CORNERS AND DETAILS
Horizontal fitting 45deg mitre-cut for perfect regular corners or
aluminium corner profile with adapted RAL colour
Vertical fitting and soffits aluminium corner profile with
adapted RAL colour
NATURAL COLOURS
Due to the inherent disparities in the standardisation of screens and printing inks the shades depicted onthis sheet may appear slightly different to those of the actual samples
EarthRAL 8019
OceanRAL 7046
SandRAL 1019
HeatRAL 8017
NightRAL 9004
RAL EQUIVALENCESAbove mentioned RAL colours are matching the best to VESTAreg eco-materialrsquos tint but can not be
considered as exactly similar The given indications are informative the responsibility lies with the
customer to determine whether the RAL color fits to its project or doesnrsquot
SunRAL 1011
SIX NATURAL COLOURS TINTED THROUGHOUT WITH MINERAL PIGMENTS(Informative RAL colours for accessories)
AGEING
bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour
bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end
colourbull Final patina will be achieved within 10 weeks in average
BOARDS AGEING PROCESS
The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint
NIG
HT
OC
EacuteAN
SAN
DSU
NH
EAT
Day 1 Installation After 10 weeks
EAR
TH
PROFILES amp ACCESSORIES
References Products Profiles Dimension
BF4O325O5 Cover 6 - 4 waves Ocean
BF4O325H5 Cover 6 - 4 waves Heat
BF4O325S5 Cover 6 - 4 waves Sand
BF4O325U5 Cover 6 - 4 waves Sun
BF4O325N5 Cover 6 - 4 waves Night
BF4O325E5 Cover 6 - 4 waves Earth
BF2O325O5 Cover 14 - 2 waves Ocean
BF2O325H5 Cover 14 - 2 waves Heat
BF2O325S5 Cover 14 - 2 waves Sand
BF2O325U5 Cover 14 - 2 waves Sun
BF2O325N5 Cover 14 - 2 waves Night
BF2O325E5 Cover 14 - 2 waves Earth
CORNER PROFILEReferences Products Profiles Dimension
BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean
BAPA300H1 Aluminium Corner - pack of 2 pcs Heat
BAPA300S1 Aluminium Corner - pack of 2 pcs Sand
BAPA300U1 Aluminium Corner - pack of 2 pcs Sun
BAPA300N1 Aluminium Corner - pack of 2 pcs Night
BAPA300E1 Aluminium Corner - pack of 2 pcs Earth
PIERCED STARTING PROFILEReferences Products Profiles Dimension
BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness
300 x 43 x 4 cm(L x W x H)
Colours
COVER 6 amp COVER 14Colours
Colours
Neutral
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
300 x 6 x 6 cm(L x W x H)
FIXINGS
Number of hooks msup2 COVER 614
60 cm centre-to-centre spacing 10 msup2
40 cm 60 cm centre-to-centre spacing 15 msup2
FIXING HOOKSReferences Products Profiles Dimension
BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)
A2 STAINLESS STEEL SCREWReferences
VIS BA RAL ndeg
VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Colours
Products colours
RAL color
RAL color
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
VIS INOX A2 - A2 STAINLESS STEEL SCREW
VIS BA NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
VIS ME NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
Reference Profiles Dimcm Weight in kgProduct
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
4kg
4kg
INSTALLATIONKEY PRINCIPLES
10
IMPLEMENTATION ON EXTERNAL THERMAL INSULATION
Horizontal fitting
Vertical fitting
TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS
Timber frame wall
Concrete wall
Timber frame wall
Concrete wall
Insulation
Insulation
IMPORTANT
Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm
Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight
This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation
In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)
IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)
Horinzontal fitting
IMPORTANT
Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm
Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height
This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation
In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)
Steelstructure
Liner trays
Vertical fitting
Insulation
Insulation
Steelstructure
Liner trays
REMARQUES IMPORTANTES SUR LA POSE
BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)
Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)
Thickness 285 mm (tolerance of plusmn 115 mm)
Squaring has to be done on site
Boards have to be calibrated according to layout
START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the
boards in the same orientation in order to obtain a uniform colour Indeed the random brushing
creates an effect on the surface that capture the lights differently according the boards orientation
Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top
IMPORTANT NOTICES
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
Groove at the bottom
Horizontal intallation
Tongue at the top
Verticalinstallation
Profil alu de deacutepart visseacute
Screwed aluminium starting profile
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
NATURAL COLOURS
Due to the inherent disparities in the standardisation of screens and printing inks the shades depicted onthis sheet may appear slightly different to those of the actual samples
EarthRAL 8019
OceanRAL 7046
SandRAL 1019
HeatRAL 8017
NightRAL 9004
RAL EQUIVALENCESAbove mentioned RAL colours are matching the best to VESTAreg eco-materialrsquos tint but can not be
considered as exactly similar The given indications are informative the responsibility lies with the
customer to determine whether the RAL color fits to its project or doesnrsquot
SunRAL 1011
SIX NATURAL COLOURS TINTED THROUGHOUT WITH MINERAL PIGMENTS(Informative RAL colours for accessories)
AGEING
bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour
bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end
colourbull Final patina will be achieved within 10 weeks in average
BOARDS AGEING PROCESS
The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint
NIG
HT
OC
EacuteAN
SAN
DSU
NH
EAT
Day 1 Installation After 10 weeks
EAR
TH
PROFILES amp ACCESSORIES
References Products Profiles Dimension
BF4O325O5 Cover 6 - 4 waves Ocean
BF4O325H5 Cover 6 - 4 waves Heat
BF4O325S5 Cover 6 - 4 waves Sand
BF4O325U5 Cover 6 - 4 waves Sun
BF4O325N5 Cover 6 - 4 waves Night
BF4O325E5 Cover 6 - 4 waves Earth
BF2O325O5 Cover 14 - 2 waves Ocean
BF2O325H5 Cover 14 - 2 waves Heat
BF2O325S5 Cover 14 - 2 waves Sand
BF2O325U5 Cover 14 - 2 waves Sun
BF2O325N5 Cover 14 - 2 waves Night
BF2O325E5 Cover 14 - 2 waves Earth
CORNER PROFILEReferences Products Profiles Dimension
BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean
BAPA300H1 Aluminium Corner - pack of 2 pcs Heat
BAPA300S1 Aluminium Corner - pack of 2 pcs Sand
BAPA300U1 Aluminium Corner - pack of 2 pcs Sun
BAPA300N1 Aluminium Corner - pack of 2 pcs Night
BAPA300E1 Aluminium Corner - pack of 2 pcs Earth
PIERCED STARTING PROFILEReferences Products Profiles Dimension
BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness
300 x 43 x 4 cm(L x W x H)
Colours
COVER 6 amp COVER 14Colours
Colours
Neutral
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
300 x 6 x 6 cm(L x W x H)
FIXINGS
Number of hooks msup2 COVER 614
60 cm centre-to-centre spacing 10 msup2
40 cm 60 cm centre-to-centre spacing 15 msup2
FIXING HOOKSReferences Products Profiles Dimension
BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)
A2 STAINLESS STEEL SCREWReferences
VIS BA RAL ndeg
VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Colours
Products colours
RAL color
RAL color
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
VIS INOX A2 - A2 STAINLESS STEEL SCREW
VIS BA NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
VIS ME NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
Reference Profiles Dimcm Weight in kgProduct
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
4kg
4kg
INSTALLATIONKEY PRINCIPLES
10
IMPLEMENTATION ON EXTERNAL THERMAL INSULATION
Horizontal fitting
Vertical fitting
TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS
Timber frame wall
Concrete wall
Timber frame wall
Concrete wall
Insulation
Insulation
IMPORTANT
Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm
Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight
This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation
In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)
IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)
Horinzontal fitting
IMPORTANT
Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm
Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height
This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation
In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)
Steelstructure
Liner trays
Vertical fitting
Insulation
Insulation
Steelstructure
Liner trays
REMARQUES IMPORTANTES SUR LA POSE
BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)
Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)
Thickness 285 mm (tolerance of plusmn 115 mm)
Squaring has to be done on site
Boards have to be calibrated according to layout
START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the
boards in the same orientation in order to obtain a uniform colour Indeed the random brushing
creates an effect on the surface that capture the lights differently according the boards orientation
Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top
IMPORTANT NOTICES
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
Groove at the bottom
Horizontal intallation
Tongue at the top
Verticalinstallation
Profil alu de deacutepart visseacute
Screwed aluminium starting profile
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
AGEING
bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour
bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end
colourbull Final patina will be achieved within 10 weeks in average
BOARDS AGEING PROCESS
The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint
NIG
HT
OC
EacuteAN
SAN
DSU
NH
EAT
Day 1 Installation After 10 weeks
EAR
TH
PROFILES amp ACCESSORIES
References Products Profiles Dimension
BF4O325O5 Cover 6 - 4 waves Ocean
BF4O325H5 Cover 6 - 4 waves Heat
BF4O325S5 Cover 6 - 4 waves Sand
BF4O325U5 Cover 6 - 4 waves Sun
BF4O325N5 Cover 6 - 4 waves Night
BF4O325E5 Cover 6 - 4 waves Earth
BF2O325O5 Cover 14 - 2 waves Ocean
BF2O325H5 Cover 14 - 2 waves Heat
BF2O325S5 Cover 14 - 2 waves Sand
BF2O325U5 Cover 14 - 2 waves Sun
BF2O325N5 Cover 14 - 2 waves Night
BF2O325E5 Cover 14 - 2 waves Earth
CORNER PROFILEReferences Products Profiles Dimension
BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean
BAPA300H1 Aluminium Corner - pack of 2 pcs Heat
BAPA300S1 Aluminium Corner - pack of 2 pcs Sand
BAPA300U1 Aluminium Corner - pack of 2 pcs Sun
BAPA300N1 Aluminium Corner - pack of 2 pcs Night
BAPA300E1 Aluminium Corner - pack of 2 pcs Earth
PIERCED STARTING PROFILEReferences Products Profiles Dimension
BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness
300 x 43 x 4 cm(L x W x H)
Colours
COVER 6 amp COVER 14Colours
Colours
Neutral
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
300 x 6 x 6 cm(L x W x H)
FIXINGS
Number of hooks msup2 COVER 614
60 cm centre-to-centre spacing 10 msup2
40 cm 60 cm centre-to-centre spacing 15 msup2
FIXING HOOKSReferences Products Profiles Dimension
BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)
A2 STAINLESS STEEL SCREWReferences
VIS BA RAL ndeg
VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Colours
Products colours
RAL color
RAL color
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
VIS INOX A2 - A2 STAINLESS STEEL SCREW
VIS BA NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
VIS ME NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
Reference Profiles Dimcm Weight in kgProduct
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
4kg
4kg
INSTALLATIONKEY PRINCIPLES
10
IMPLEMENTATION ON EXTERNAL THERMAL INSULATION
Horizontal fitting
Vertical fitting
TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS
Timber frame wall
Concrete wall
Timber frame wall
Concrete wall
Insulation
Insulation
IMPORTANT
Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm
Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight
This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation
In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)
IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)
Horinzontal fitting
IMPORTANT
Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm
Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height
This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation
In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)
Steelstructure
Liner trays
Vertical fitting
Insulation
Insulation
Steelstructure
Liner trays
REMARQUES IMPORTANTES SUR LA POSE
BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)
Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)
Thickness 285 mm (tolerance of plusmn 115 mm)
Squaring has to be done on site
Boards have to be calibrated according to layout
START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the
boards in the same orientation in order to obtain a uniform colour Indeed the random brushing
creates an effect on the surface that capture the lights differently according the boards orientation
Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top
IMPORTANT NOTICES
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
Groove at the bottom
Horizontal intallation
Tongue at the top
Verticalinstallation
Profil alu de deacutepart visseacute
Screwed aluminium starting profile
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
PROFILES amp ACCESSORIES
References Products Profiles Dimension
BF4O325O5 Cover 6 - 4 waves Ocean
BF4O325H5 Cover 6 - 4 waves Heat
BF4O325S5 Cover 6 - 4 waves Sand
BF4O325U5 Cover 6 - 4 waves Sun
BF4O325N5 Cover 6 - 4 waves Night
BF4O325E5 Cover 6 - 4 waves Earth
BF2O325O5 Cover 14 - 2 waves Ocean
BF2O325H5 Cover 14 - 2 waves Heat
BF2O325S5 Cover 14 - 2 waves Sand
BF2O325U5 Cover 14 - 2 waves Sun
BF2O325N5 Cover 14 - 2 waves Night
BF2O325E5 Cover 14 - 2 waves Earth
CORNER PROFILEReferences Products Profiles Dimension
BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean
BAPA300H1 Aluminium Corner - pack of 2 pcs Heat
BAPA300S1 Aluminium Corner - pack of 2 pcs Sand
BAPA300U1 Aluminium Corner - pack of 2 pcs Sun
BAPA300N1 Aluminium Corner - pack of 2 pcs Night
BAPA300E1 Aluminium Corner - pack of 2 pcs Earth
PIERCED STARTING PROFILEReferences Products Profiles Dimension
BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness
300 x 43 x 4 cm(L x W x H)
Colours
COVER 6 amp COVER 14Colours
Colours
Neutral
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
325 x 30 x 285 cm(L x W x H)
1 pcs = 0975 sqm
300 x 6 x 6 cm(L x W x H)
FIXINGS
Number of hooks msup2 COVER 614
60 cm centre-to-centre spacing 10 msup2
40 cm 60 cm centre-to-centre spacing 15 msup2
FIXING HOOKSReferences Products Profiles Dimension
BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)
A2 STAINLESS STEEL SCREWReferences
VIS BA RAL ndeg
VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Colours
Products colours
RAL color
RAL color
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
VIS INOX A2 - A2 STAINLESS STEEL SCREW
VIS BA NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
VIS ME NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
Reference Profiles Dimcm Weight in kgProduct
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
4kg
4kg
INSTALLATIONKEY PRINCIPLES
10
IMPLEMENTATION ON EXTERNAL THERMAL INSULATION
Horizontal fitting
Vertical fitting
TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS
Timber frame wall
Concrete wall
Timber frame wall
Concrete wall
Insulation
Insulation
IMPORTANT
Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm
Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight
This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation
In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)
IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)
Horinzontal fitting
IMPORTANT
Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm
Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height
This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation
In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)
Steelstructure
Liner trays
Vertical fitting
Insulation
Insulation
Steelstructure
Liner trays
REMARQUES IMPORTANTES SUR LA POSE
BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)
Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)
Thickness 285 mm (tolerance of plusmn 115 mm)
Squaring has to be done on site
Boards have to be calibrated according to layout
START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the
boards in the same orientation in order to obtain a uniform colour Indeed the random brushing
creates an effect on the surface that capture the lights differently according the boards orientation
Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top
IMPORTANT NOTICES
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
Groove at the bottom
Horizontal intallation
Tongue at the top
Verticalinstallation
Profil alu de deacutepart visseacute
Screwed aluminium starting profile
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
FIXINGS
Number of hooks msup2 COVER 614
60 cm centre-to-centre spacing 10 msup2
40 cm 60 cm centre-to-centre spacing 15 msup2
FIXING HOOKSReferences Products Profiles Dimension
BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)
A2 STAINLESS STEEL SCREWReferences
VIS BA RAL ndeg
VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Colours
Products colours
RAL color
RAL color
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
VIS INOX A2 - A2 STAINLESS STEEL SCREW
VIS BA NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
VIS ME NdegRAL Laqueacutee RALRAL color
16 x 11 x 7 cm(L x l x H L x W x H ) 15kg
Reference Profiles Dimcm Weight in kgProduct
Wood amp Alu screw tinted head - Box of 500 units
42 x 32mm - Inox A2 A2 stainless steel
Bi-metal Steel screw tinted head - Box of 500 units
48 x 21mm - Inox A2 A2 stainless steel
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019
4kg
4kg
INSTALLATIONKEY PRINCIPLES
10
IMPLEMENTATION ON EXTERNAL THERMAL INSULATION
Horizontal fitting
Vertical fitting
TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS
Timber frame wall
Concrete wall
Timber frame wall
Concrete wall
Insulation
Insulation
IMPORTANT
Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm
Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight
This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation
In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)
IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)
Horinzontal fitting
IMPORTANT
Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm
Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height
This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation
In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)
Steelstructure
Liner trays
Vertical fitting
Insulation
Insulation
Steelstructure
Liner trays
REMARQUES IMPORTANTES SUR LA POSE
BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)
Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)
Thickness 285 mm (tolerance of plusmn 115 mm)
Squaring has to be done on site
Boards have to be calibrated according to layout
START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the
boards in the same orientation in order to obtain a uniform colour Indeed the random brushing
creates an effect on the surface that capture the lights differently according the boards orientation
Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top
IMPORTANT NOTICES
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
Groove at the bottom
Horizontal intallation
Tongue at the top
Verticalinstallation
Profil alu de deacutepart visseacute
Screwed aluminium starting profile
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
INSTALLATIONKEY PRINCIPLES
10
IMPLEMENTATION ON EXTERNAL THERMAL INSULATION
Horizontal fitting
Vertical fitting
TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS
Timber frame wall
Concrete wall
Timber frame wall
Concrete wall
Insulation
Insulation
IMPORTANT
Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm
Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight
This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation
In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)
IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)
Horinzontal fitting
IMPORTANT
Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm
Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height
This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation
In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)
Steelstructure
Liner trays
Vertical fitting
Insulation
Insulation
Steelstructure
Liner trays
REMARQUES IMPORTANTES SUR LA POSE
BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)
Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)
Thickness 285 mm (tolerance of plusmn 115 mm)
Squaring has to be done on site
Boards have to be calibrated according to layout
START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the
boards in the same orientation in order to obtain a uniform colour Indeed the random brushing
creates an effect on the surface that capture the lights differently according the boards orientation
Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top
IMPORTANT NOTICES
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
Groove at the bottom
Horizontal intallation
Tongue at the top
Verticalinstallation
Profil alu de deacutepart visseacute
Screwed aluminium starting profile
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
IMPLEMENTATION ON EXTERNAL THERMAL INSULATION
Horizontal fitting
Vertical fitting
TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS
Timber frame wall
Concrete wall
Timber frame wall
Concrete wall
Insulation
Insulation
IMPORTANT
Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm
Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight
This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation
In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)
IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)
Horinzontal fitting
IMPORTANT
Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm
Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height
This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation
In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)
Steelstructure
Liner trays
Vertical fitting
Insulation
Insulation
Steelstructure
Liner trays
REMARQUES IMPORTANTES SUR LA POSE
BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)
Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)
Thickness 285 mm (tolerance of plusmn 115 mm)
Squaring has to be done on site
Boards have to be calibrated according to layout
START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the
boards in the same orientation in order to obtain a uniform colour Indeed the random brushing
creates an effect on the surface that capture the lights differently according the boards orientation
Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top
IMPORTANT NOTICES
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
Groove at the bottom
Horizontal intallation
Tongue at the top
Verticalinstallation
Profil alu de deacutepart visseacute
Screwed aluminium starting profile
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)
Horinzontal fitting
IMPORTANT
Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm
Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height
This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation
In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)
Steelstructure
Liner trays
Vertical fitting
Insulation
Insulation
Steelstructure
Liner trays
REMARQUES IMPORTANTES SUR LA POSE
BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)
Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)
Thickness 285 mm (tolerance of plusmn 115 mm)
Squaring has to be done on site
Boards have to be calibrated according to layout
START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the
boards in the same orientation in order to obtain a uniform colour Indeed the random brushing
creates an effect on the surface that capture the lights differently according the boards orientation
Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top
IMPORTANT NOTICES
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
Groove at the bottom
Horizontal intallation
Tongue at the top
Verticalinstallation
Profil alu de deacutepart visseacute
Screwed aluminium starting profile
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
REMARQUES IMPORTANTES SUR LA POSE
BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)
Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)
Thickness 285 mm (tolerance of plusmn 115 mm)
Squaring has to be done on site
Boards have to be calibrated according to layout
START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the
boards in the same orientation in order to obtain a uniform colour Indeed the random brushing
creates an effect on the surface that capture the lights differently according the boards orientation
Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top
IMPORTANT NOTICES
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
Groove at the bottom
Horizontal intallation
Tongue at the top
Verticalinstallation
Profil alu de deacutepart visseacute
Screwed aluminium starting profile
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
REMARQUES IMPORTANTES SUR LA POSE
ALWAYS KEEP A 6 MM EXPANSION JOINT
A minimum space of 6mm between the 325m boards
and contiguous elements (joinery wall other cladding
boards) should be left to enable the natural expansion
of the NEOLIFEreg cladding boards
Always maintain 15 mm expansion per linear meter
(or 2mm in case of high temperature variations)
IMPORTANT NOTICES
NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes
The professional rules and recommendations governing the cladding installation must be followed
NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade
They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing
element in compliance with the local Building Regulations
FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing
Anything fixed to the facade must be attached to the supporting structure behind the cladding
6mm
CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at
wwwneolife-solutionscom website are not a substitute to regulations concerning safety
environment and regulatory installation specifications
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES
The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge
both in horizontal and vertical installations
EPDM strip
Concrete wall
1 Batten min size 60mmOr 2 battens min size 27x40mm
6 mm expansion joint
PREPARATION OF THE STRUCTURE
CAUTION
Make sure to respect the cladding installation steps recommended by the local professional guidelines
IMPORTANT ADVICES
The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of
27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance
following the buildingrsquos category and height
The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without
external insulation
Always keep a minimum 2cm air gap for ventilation behind the cladding (check the
recommendations of the local regulations )
The supporting structure has to be placed perpendicular to the cladding For vertical installation
the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following
the local recommendations)
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
Wide board With 300 mm width
KEY INSTALLATION PRINCIPLES
Mitre cut with perfectly aligned grooving
Horizontal or vertical fitting with various layouts
Invisible fixing using steel hooks screwed into the wood or metal supporting structures
Fast fixing using screwed steel hooks
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories
Vertical fitting with a corner profile
6mm open expansion gapat the end of the board
Horizontal fittingwith a mitre cut
or with a corner profile
Metal CopingWindow revealwith metal profile
Outside corner or window reveal with Neolife corner profile
KEY INSTALLATION PRINCIPLES
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
DESIGN GUIDELINES
When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)
Flat metall elements without watertightnessmanagement Dirty water runoff causes stains
Advice
Leave space between cladding and the signand fix it on the load-bearing wall
INSTALLATION OF SHOP SIGN
OTHERS
Sign stuck onto the wall Sign away from the wall
Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding
infiltration Seal and fixing
Cutting for expansion
Flat Casquette
Fixing againstthe wall
Absence of water drop Water drop
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
DESIGN GUIDELINES
BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide
available on our website wwwneolife-solutionscom
Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation
Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining
WINDOW SILL
Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding
Flat metal window sill
30mm
Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile
no ventilation
Visible screwWater storage
Hidden screw
Perforated closure profile ventilation and water runoff
5mm
ENDINGS JUNCTIONS
Absence of water drop Water drop
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
REMARQUES IMPORTANTES SUR LA POSECAUTION
THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT
wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
MAINTENANCE
21
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the
grooves rain stains can appear on the surface
NEOLIFE strongly recommend to clean the boards after implementation with a pressure
washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT
USE a rotary nozzle)
Recommendations
Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the
cladding after the first rain (windows are frequently dusty during construction)
All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in
order to limit the water runoff on the cladding Shop signs or any other elements installed on
the cladding have to be moved forward (space left between cladding and the element) to
avoid any stains
Caution
If any operation involving the use of asphalt or concrete occurs after facade completion
NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains
Indeed if not protected a greasy steam can spread on the surface and in the grooves In that
case a grease-removing product will be needed to clean the boards and all the surrounding
elements
BUILDING SITE CLEANING
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
LONG LASTING
VERY LIMITED MAINTENANCE
The material does not require any wood preservative (oils varnishes saturators hellip)
bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)
bull Highly hydrophobic and rot-proof no algae fungi or moss development
bull Insect-resistant does not require any treatments against termites
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
STAIN REMOVAL
STAINS
Tanin stains
During the first weeks after installation tannin rings may occur because of the rain especially
on claddings with a light colour They will be washed off and fade during the next rain to
lessen until they completely disappear Be careful not to mistake these stains with dust or
pollution stains which appear on all cladding types
Bleach-based cleaning products
Slight discolouration Clean with water and complete if needed with slight brushing in the
boards orientation
Graffities oil paint and ink
Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)
Bitumen grease
Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)
Oxidation stains after contact with a corroded metal
Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)
Caution
- Analyse properly the substance to clean so to use the right stain removing product
- Always test the stain removing product on a small and discrete surface before cleaning the
entire board
- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the
solution you choose will not react with the cladding and therefore produce unsightly effects
DAMAGES
bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
TECHNICAL CHARACTERISTICS
25
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
SYSTEM PERFORMANCES
DESIGNATIONTEST
METHODS amp STANDARDS
CLADDING OUTLIFE COVER 6 amp 14
WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)
Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing
pressure Test results Maximum shearingpressure
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
4 900 Pa
(degradation)140 kNm2 5 200 Pa
(degradation) 148 kNm2
Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2
IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)
Fixings description NF P 08302 Test results Test results
Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction
No damage with the impact energies below
Soft impacts 50Kg 130J
Soft impacts 3Kg 20J
Hard impacts 1Kg 3J
No damage with the impact energies below Soft impacts 50Kg 130J
Soft impacts 3Kg 20JHard impacts 1Kg 3J
SEISMIC RESISTANCE COVER 6 amp14
COVER 6 amp 14can be installed in seismic zones and buildings according to the following details
Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test
FIRE RESISTANCE COVER 6 COVER 14
Tests description EN 13823 et EN 13501-12007
Fire rating
(on A2-s1d0 wall)
Fire rating
(on A2-s1d0 wall)
SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide
dihedral wedge Assembly on air board and horizontal wood batten Valable contre un
substrat A2-s1d0
B-s3d0
Equivalent UK class 0
FIGRA average 1151Ws
THR average 6MJ
SMOGRA average 371 m2s2
B-s3d0
Equivalent UK class 0
FIGRA average 1924Ws
THR average 112MJ
SMOGRA average 592m2s2
Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
PHYSICAL AND MECHANICAL FEATURES
DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING
FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ
APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14
Test descriptionNF EN 927-6 (2006)
FCBA‐ LBO6-PHY‐001
Test results
Artificial ageing test under QUV allowing an assessment of durability and decorative
properties modification Total duration 10 weeks comprising
condensation UV radiation and water spray phases
Stable products according to the EN 927-2
No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0
THERMAL EXPANSION COVER 6 amp 14
Test description
ISO 11359-2 adapted to
FCBA - LBO6PHY-001
Test results
Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils
thermal expansion coefficient in solid state
Coefficient de dilatation thermique moyen
Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards
WATER UPTAKE DETERMINATION COVER 6 amp 14
Test description FCBA‐LBO‐MECA‐014 Test results
Water uptake determination after immersion in cold water during 28 days Measure of the
mass in its initial state and after 124714 et 28 days
Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143
ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14
Test description
FCBA‐LBO‐MECA‐008
NF EN 310 modifiedWPC profiles
Test results
3 point flexion under normal conditions 20degCand 65 RH
Eaverage = 904 Nmm2fm = 40 Nmm2
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
ENVIRONMENTAL CHARACTERISTICS
28
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
VESTAreg ECO-MATERIAL
VESTAreg (Vegetal Ecological Stable Timber
Advantage) is an innovative and eco-friendly compound
with exceptional properties It was developed by
NEOCOreg NEOLIFEreglsquos Research Centre specialising in
green technologies in partnership with European experts
EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of
environmental solutions for construction projects and the
landscaping of outside spaces It finally brings a response
to the architects landscapers and design officesrsquo
demands working on eco-construction and sustainable
development projects
ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively
from sawmills offcuts the wood coming from sustainably
managed European forests The production of our material
does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover
NEOLIFE does not use any toxic additives in the production process of the material
VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled
components for which establishing a traceability is impossible)
CLEANDoes not contain solvents adhesives or phthalates and does not generate
toxic emissions
STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The
formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as
well as an outstanding design
The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the
exposure
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
SOURCE
Raw material VESTAreg
X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests
Board Production France
COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments
PHYSICAL PROPERTIES
Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2
Density 1500 kgm3
Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites
Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free
Scratches resistance Equivalent to natural wood - Brushing possible without discolouration
Thermal inertia Low thermal inertia due to the high wood fibres content
ENVIRONMENTAL PROPERTIES
Recycling 100 recyclable 75 renewable and combustible (75 biomass)
Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)
Chemical fire retardant substance None
Solvents None
Heavy metals None lead-and mercury-free stabilization
Phthalates adhesives None
Formaldehydes and VOCs Lower than or equal to natural wood
VESTAreg REINFORCED WOOD FIBER
VESTA X-FIRE
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
ENVIRONMENTAL PRODUCT DECLARATION
1 - Values describing the environmental impacts
Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507
Publication 10072015 Validity 10072020
Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN
Environmental Declaration of the COVER productavailable on request
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
ENVIRONMENTAL PRODUCT DECLARATION
2 ndash Values describing the use of primary energetic sources other resources and water
3 ndash Complementary values describing the outflows
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
FURTHER DETAILS
33
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
TECHNICAL DESCRIPTION
French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)
Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex
VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres
Boards with a slatted aspect featuring 6 cm or 14 cm ribs
Fire rating with natural mineral salts following EN 13501-12007
COVER 6 B-s3-d0 minimum
COVER 14 B-s3-d0 minimum
Invisible fixing with stainless steel hooks screwed into wood or metal battens
Fast and accurate fitting thanks to the interlocking board system
Outside corners catered for by using 45deg miter cuts or aluminium corner profile
Dimensional stability of maximum 2mm m over ∆80degC
rot-proof not sensitive to moss and mould
Insect-resistant termites included
Stable colors after natural patina is acquired
Contact us to get the full technical specification sheet
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom
CONTACT
CAUTION
This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom
NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters
disposal for any clarifications concerning the installation procedure of its products
The specifications and recommendations given in the installation guide are not a
substitute to regulations concerning safety environment and professional regulatory
dispositions
All instructions concerning the installation of our cladding are to be followed
Assembly errors are not covered by the NEOLIFEreg guarantee
An approved fitter shall be able to assess the construction conformity to the local
professional installation guidelines
304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47
wwwneolife-solutionscom