COSEC DOORDoor Controller
Quick Start
S E C U R I T Y S O L U T I O N S
HID R10/RW100Reader
Red
Black
Green
White
Orange
Brown
Yellow
Blue
1
20
T1 T2
21
40
COMNC
NO
GND
D0D1
DATA RTN
Green LED
Red LED
Beeper
Hold
COM
Tamper
RS-232 R
RS-232 T
Status LED
Alarm LED
Exit SW
COM
Rdr pwr
COMNC
NO
0V
0VLock Tamper
COM
Door STS In+
COM
Aux In+
COM
A
B
Shield
+12VDC
0V
+12V
A
B
Shield
LoopIn
LoopOut
T Rex
Door Magnet
DoorContact
Terminals of Premium DOOR
Connection Diagram for the COSEC DOOR
Terminals of Standard DOOR
1
20
T1
+12V
0V
A-Loop In
Shield
Aux In
COM
STS In
COM
Data RTN
D0
D1
Green LED
Red LED
Beeper
Hold
Tamper NC/NO
B-Loop In
A-Loop Out
Shield
B-Loop Out
PANEL Terminal Strip
A
DoorContact
To A of Door 2
To B of Door 2
HID R10/RW100Reader
(External)
To pin 34
Green
White
Orange
Brown
Yellow
Blue
To pin 33Black
Red
-
8/13/2019 COSEC DOOR Quick Start Booklet
4/16
Introduction
CongratulationsonchoosingtheMatrixCOSECDOOR
Controller.Thisquickstartguideismeanttohelpyouin
completingtheinstallationoftheCOSECDOORController
Hardwarecomponents.Fordetailedinformationonthe
installationandconfigurationoftheCOSECsystem,youmay
referthe'COSECSystemManual'acopyofwhichisavailable
ontheCDROM
BeforeYouStart
VerifyPackageContent
Unpackthesystem.Makesurethatyourpackagecontainsall
thebelowitems.Ifanyitemismissingordamaged,please
contactthesourcefromwhereyouhavepurchasedthesystem.
COSECDOORUnit
QuickStartandUserCard
Adapter12VDC(CountrySpecific)
FourScrewsM7/30
FourScrewGrips
ThreadedScrewM3x6
MountingPlateWarrantyCardSet
EthernetportwithanEthernetcrossover/Straightcable.A
crossovercableisacablethatmapsalloutputsignalson
oneconnectortotheinputsignalsontheotherconnector.
ThisallowsthecomputerandtheDoortoperformfull-
duplexEthernetcommunication.
DIRECTDOOR COSECMonitorPC
Crossover/StraightCable
OncetheIPaddressoftheDIRECTDOORhasbeen
changedfromitsdisplayoritswebpageasexplained,
proceedwiththefurtherconfigurationoftheDOOR
ControllerasexplainedintheCOSECSystemManual.
However,theuserneedstokeepanoteoftheIPsettingsassetontheDIRECTDOORasthesamewouldhavetobe
enteredintheNetworkparameterssectionontheDoors
optionpageoftheCOSECapplication.
ThePANELDOORsontheotherhandareassignedtheirIP
addressesbythePANELbasedontheControllerNetwork
ParametersasdefinedintheNetworkParameterspageof
theCOSECJeevesapplicationasexplainedintheCOSEC
PANELQuickStartaswellastheCOSECSystemmanual.
-
8/13/2019 COSEC DOOR Quick Start Booklet
5/16
Know your COSEC DOOR
The COSEC DOOR can be configured as a PANEL DOOR or
DIRECT DOOR and are designed to control a single Door. The
PANEL DOOR, as the name suggests connects to the COSECPANEL which in turn connects to the COSEC Monitor
application.
PANEL DOORs depend on the PANEL for configuration while
DIRECT DOORs are configured directly from the COSEC
application platform. The COSEC DIRECT DOOR configuration
has limited functionalities compared to the PANEL DOOR
configuration as explained in the COSEC System manual.
The COSEC PANEL DOOR Controller supports the followingoptions:
1 Ethernet and RS485 communication port
LCD Display1
4 LEDs. (Status, Alarm, Allow, Deny)
2 Internal Readers
1 External Reader port
1 Door Relay
1 Aux input and output ports
Touch sense Keypad1
Door Sense and Exit Switch Inputs.
The COSEC DIRECT DOOR connects directly to the COSEC
Monitor application.
The COSEC DIRECT DOOR Controller supports the following
options:
1 Variants available without these options.
The user can now edit the Ethernet or wireless IP settings
based on the communication type being used by the DOOR
in the right pane of the web page.
Connect ing the COSEC DIRECT DOOR to the
Monitoring PCConnect your computer's Ethernet port and the DOOR's
Ethernet Port by using either of two below mentioned
methods.
1. Connect both the computer's and the DOOR's Ethernet
port to an Ethernet hub with standard straight-through
Ethernet patch cables as shown.
Ethernet Switch
DIRECT DOOR
COSECMonitor PC
-
8/13/2019 COSEC DOOR Quick Start Booklet
6/16
1Ethernetcommunicationport
LCDdisplay
4LEDs.(Status,Alarm,Allow,Deny)
2InternalReaders
1ExternalReaderport
1DoorRelay,1AuxinputandAuxoutputport
TouchsenseKeypad
DoorSenseandExitSwitchinputs.
TheCOSECDOORisequippedwithmultiplereaderinterfaces
toreadvariouscredentialinputsasprovidedbytheuser.
ADoorrelayportisavailabletocontrolanaccesspointasalso
adoorsenseinputtomonitortheaccesspointstatusthrougha
doorsensedevice.TheCOSECDOORControllerissupported
withmultipleuserinterfaceslikeKeypad,multi-colorLED,
BuzzerandLCDdisplayinadditiontotheReadersto
communicatewithuser.Withinputdevicesupportthiscontroller
canreadusercredentialsfromcardreaders,FPIDfromfingerprintidentificationmodulesandPINcodeinputthroughthe
touchsensekeypad.
Inadditiontotheabove,theCOSECDOORisdesignedto
supportRequestforExitthroughEXITswitchorthroughanExit
reader(interfacedthroughRS232/Wiegandport).
TheCOSECPANELDOORalsoprovidesanAuxinputand
outputport.TheAuxinputportcanbeusedtointerfacewith
suitablesensorstodetectanalarmcondition.TheAuxoutputcanbeusedforactivatingsomealarmdeviceslikehooter,
energizesomedevicesortocontrolsomeannunciation
devices.BoththeAuxinputandAuxoutputportsareuser
configurableandcanbegrouped&linkedwithotherCOSEC
PANELDOORControllerportsaspertherequiredaction.
thenewSubnetMask.
TochangetheGatewaySettingsoftheDIRECTDOOR,
presstheNumberkey3toselecttheSMoptionorscroll
totheoptionandpresstheENTkey.Thesystemwill
promptforthenewGatewayIPaddress.Similarly,the
administratorcanalsoconfiguretheDNSaswellasthe
ListeningPortsettingsbyselectingtheappropriate
optionsfromtheLANsettingsoptionoftheDIRECTDOOR.
KeyinthenewIPsettingsfortheaboveparametersas
shownintheabovedisplay.Thesystemwilldisplaythe
statusoftheupdatedsettingsandreturntothedefault
screen.
ConfiguringfromtheDIRECTDOORDISPLAY:
TheadministratorcanconfiguretheIPaddressofthe
DIRECTDOORbyaccessingthewebpageoftheDIRECTDOOR.
ToconnecttotheDIRECTDOORsconnecttheDOORson
theNetworkasexplainedinthenextsection:
StarttheInternetExplorer.
Typeinhttp://192.168.50.50intheAddressfield.
ClickEntertocontinue.
Theloginpageoftheonboardwebpageappears.
EnteradminastheUserandtypeinthedefaultpasswordadmininthepasswordfieldand
clickLogin.
TheCOSECDOORwebpageappears.Clickon
NetworkConfigurationoptionintheleftpaneas
shown.
-
8/13/2019 COSEC DOOR Quick Start Booklet
7/16
The DIRECT DOOR communicates with the COSEC Monitor
application over the TCP/IP network. The PANEL DOOR
Controller communicates with PANEL in either of the following
two ways:
1. Serial port communication using the RS 485 interface.
2. Ethernet based packet communication using the LANinterface.
Though the PANEL DOOR Controller supports both RS 485 and
Ethernet communication ports, only one of the two interfaces
can be activated through configuration.
The Ethernet port uses standard IP address scheme to identify
the Controller and they can be changed depending on the site
requirement.
The RS 485 address on the PANEL DOOR is set using the 5
DIP switches located at the rear of the DOOR enclosure and
they support address range of 00 to 31. On the other hand, the
DIP switches on the DIRECT DOORs are used to default the
various settings on the DIRECT DOOR as explained in the
COSEC System manual.
The COSEC Access control system is designed to support up to
32 COSEC PANEL DOORs using RS485 communication underone PANEL and 75 PANEL DOORs with Ethernet interface.
However, the system supports a total of 75 PANEL DOORs in a
heterogeneous network under one PANEL.
Mounting and Wiring the COSEC DOOR
Before installing the COSEC DOOR:
The COSEC DOOR has been designed to be mounted on a wall
in a single box without any additional enclosure.
MON 21-DEC 15:22 MON 21-DEC 15:22
1 LAN Settings2 Set Date and Time3 Door4 Password
5 Communication TypeAdmi n
1 IP: 192.168.50.502 SM: 255.255.255.03 GW:
4 DNS:5 Listening Port
LAN Setting
Select the LAN Settingsoption by pressing the ENT key at
the above display or pressing the Number key 1. The
DIRECT DOOR displays the IP settings window as shown.
To change the IP address of the DIRECT DOOR, press the
Number key 1to select the IP option or just press the ENT
key.
The system will prompt for the new IP address as shown.
MON 21-DEC 15:22 MON 21-DEC 15:22
IP Address
192.168.50.50New:
LAN SettingLAN Setting
IP Address
192.168.50.50New: 010.001.050.100
To change the Subnet Mask of the DIRECT DOOR, press
the Number key 2 to select the SM option or scroll to the
option and press the ENTkey. The system will prompt for
-
8/13/2019 COSEC DOOR Quick Start Booklet
8/16
Step1:UnpackingtheDoorController
1.UnpacktheCOSECDOORControllerpackage.The
followingitemsarerequiredtoinstallthedoorcontroller:
COSECDOORControllerwithaccessorykit(included)as
mentionedearlier.
MatrixCOSECDoorPSBB(13.8VDC@2AUniversal
MainsPSwithBatteryBackup)isnotincludedwiththe
packagebuthastobeorderedseparatelyintheeventofarequirementforbatterybackupfortheCOSECDOOR.
2.Verifythecontentforanymissingitem/partordamaged
component.Anymissingordamageditemshouldbe
reportedimmediately.
Step2:SelectingaMountingLocation
TheCOSECDOORControllershouldbeaccessibleforease
ofinstallationandmaintenance.TheDOORControllerunithasinbuiltreadersandthusitismandatorythatitshouldbe
installednexttotheaccesspoint.
Selectanideallocationusingthefollowingguidelines:
Stayawayfromelectricalorcommunicationdevices:
DOORControllersmustbelocatedataminimumdistance
of
2m(6feet)fromanyhighvoltageequipmentor
wiring(>230Volts)andfromelectricalequipment
susceptibleofgeneratingelectricalinterference1meter(3feet)fromtelephoneequipmentorlines
8meters(25feet)fromanytransmittingequipment.
TheDOORControllershouldbemountedadjacenttothe
doorprovidingnormaltemperatureandhumiditylevels.
DOORControllersshouldbelocatedadjacenttothe
controlleddoor.
DIRECTDOORwebpage
ConfiguringfromtheDIRECTDOORDISPLAY:
AfterpoweringuptheDIRECTDOORtheuserneedsto
navigatetotheAdminoptionontheDOORusingthe
keypad
anddisplay.TheAdminoptionispasswordprotectedand
givesaccesstothefollowingadministrativefunctionsontheDIRECTDOOR:
LANSettings
SetDateandTime
Door
Password
ToaccesstheAdminfunctionspresstheENTkeyonthe
DIRECTDOORkeypadandthenpressthenumerickey3or
scrolldowntotheAdminoptionandpresstheENTkey.Thesystempromptsfortheadminuserpasswordasshown.
EntertheAdminuserpassword(defaultis"1234").
MON21-DEC15:22
1TAOptions
2HRD
3Admin
MON21-DEC15:22
EnterPassword:
Thefollowingdisplayappears.
-
8/13/2019 COSEC DOOR Quick Start Booklet
9/16
In the event of the MATRIX COSEC RF module also being
included in the ordered items, the module needs to be
mounted on the COSEC DOOR prior to starting the wall
mounting procedure as shown.
Step 3:Power Supply
There are three options for providing the 12VDC @ 1 amppower input to the COSEC DOOR Controller.
A 2 conductor cable can be drawn from the terminals on
the Power supply unit of the COSEC PANEL. These can
be connected to terminals 39 & 40 of the terminal strip on
the COSEC DOOR Controller. Up to 4 COSEC DOORs
can be powered this way.
Place the threaded screw M 3x6 as provided in the
package in this slot and tighten the same to fix the Door
Controller unit to the mounting plate.
Step 9:Powering up the Door Controller
Once all the connections are checked, power up the Door
Controller which in turn will go through the booting process.
The LCD display will first display the Matrix logo followed by
the firmware version, RS485 address of the controller as set
on the dip switch and the MAC address of the door controller
for a few seconds. Make a note of this address as it will be
used in the COSEC application in the event of an Ethernet
network.
Power up all the DOOR Controllers once after they have
been defined and configured in the COSEC application as
described in the COSEC System manual. Also ensure that
the PANELS if any on the network are also powered up
prior to powering up the DOOR Controllers. This is to
ensure that the PANEL can start downloading the PANEL
DOOR firmware to all DOORs on the network which have
been configured as PANEL DOORs as this operation only
when the DOORs are in the reboot process.
Setting the IP address of the DIRECT DOOR:
The DIRECT DOORs come preconfigured with a default IP
address. The System Engineer would need to connect the
DIRECT DOORs one at a time on the network and configure
their IP address as explained in this section. There are two
ways to configure the IP settings of the DIRECT DOOR. From
the:
Direct DOOR display
-
8/13/2019 COSEC DOOR Quick Start Booklet
10/16
PowerSupply
J1
J2
J3
J5
0
12V
0
12V
0
0
12V
12V
DoorController
39
0
12V
Upto4DoorControllers
40
2.Connecttheadaptergivinganoutputof12VDC@
1~1.5Atotheterminals39and40ontheCOSECDOOR
Controllerunit.However,caremustbetakentomaintain
thecorrectpolarity.
T2
21
40
COM
NC
NO
0V
0VLockTamper
COM
DoorSTSIn+
COM
AuxIn+
COM
A
B
Shield
+12VDC
0V
+12V
A
BShield
LoopIn
LoopOut
PlacetheMountingplateonthewallandmarkthepointsfor
drillingholesforthefourwallmountingscrewsM7/30.Drilla
holeofappropriatesizeandplacethenailgripsintheholes.
Nowplacethemountingplateonthewallandmountitusing
the4wallmountingscrewsM7/30.
TheDoorControllerunitcannowbefixedontothemounting
plateusingthematchingslotsasaguide.Amatchingslotis
alsoprovidedonthebottomrightoftheDoorControllerunit
andthemountingplateforascrewasshowninthefigure.
-
8/13/2019 COSEC DOOR Quick Start Booklet
11/16
3. Connect the two cables coming from the Matrix PSBB-
Universal Mains Power supply (13.8 VDC @ 2A) with
battery backup to the terminals 39 and 40 on the COSEC
DOOR terminal strip. Here again, care must be taken to
maintain the correct polarity.
DoorController
39
0
12V
40
COSEC DOORPSBB
Power should only be applied to the unit when all
connections are completed and tested.
Step 4:Installing the COSEC DOOR Unit
The following diagram illustrates a typical door layout:
Lock Device
REX
Reader
Ethernet/RS485
COSEC PANEL
PANELDOOR
DOOR Mounting Guide
-
8/13/2019 COSEC DOOR Quick Start Booklet
12/16
Doorcloser:Astandardhydraulicdoorcloserisalmost
mandatorytoinsurethatthedoorclosesautomaticallyafter
anentryorexitandtoprevent"dooropentoolong"or"door
leftopen"alarms.
Doorcontact:Whenthedoorisclosed,theaccess
controllersupervisesthedoorcontactandwillreporta"door
forcedopen"alarmifthedoorisopenedwithouttheuseofa
card.Whenthedoorisopenedforavalidcredential,theconditionofthedoorcontactisstillsupervisedbutnoalarms
aregenerated.
Step5:ConnectingtheDoorLockingDevice
ThelockNO,COM,NCand+12VDCterminalsarelocated
atterminalnos.21,throughto24onthetoprightofthe
COSECDOORterminalstrip.Thelockingdeviceoutputis
controlledbythesoftwareaccordingtopresetparametersfor
allowingaccessorunlockingdoorsaccordingtoschedulesandaccesslevels.TheNOorNCoutputcanoperateDC
poweredlockingdevicessuchaselectromechanicalstrikes
andMagneticLocks.Themaximumpermittedcurrentis500
external12/24VDCpowersupplyhastobeusedbasedon
thetechnicalspecificationsofthemagneticlock.
T2
21 COM
NC
NO
0V
+12V
DoorMagnet
0V
initializetheIPsettings,PasswordandSystem
ParametersoftheDIRECTDOORtofactorydefaults.
2.TheEthernetRJ45connectorislocatedjustabovethe
terminalstriponthebackoftheDoorController.Connect
themaleRJ45connectorhereintheeventofthe
DIRECTDOORsortheEthernetconnectivityoption
beingusedforthePANELDOORs.
EthernetCable
StandardDOORPremiumDOOR
Step8:MountingtheDoorController
Oncealltheconnectionshavebeencompleteditistimeto
mountthedoorcontrollerunitnexttotheaccesspointsuch
asadoororturnstileasmentionedearlier.
Drillholesinthewallforinsertionofthescrewsprovided
withthedoorcontroller.Theholesaretobedrilledin
accordancewiththefollowingdimensionsofthe
mountingplateoftheDoorcontrollerunit.
-
8/13/2019 COSEC DOOR Quick Start Booklet
13/16
21COM
NC
NO
Door Magnet
12V/24VUsing an External Power Supply
For using the 12VDC of the Door controller, short the
terminals 24 (12+) and 21 (COM) as shown, prior to
connecting the NC/NO and the 0V (terminal 25) to the
Door locking device.
Step 6:Hooking up Inputs
The COSEC DOOR has on-board capacity of 4 inputs (2 inthe case of a DIRECT DOOR configuration). Except for the
Request to Exit Input, each input can be supervised with
end-of-line resistors (4.7K ohm).
19
20/30
29
Door Egress
Common
Door Status4.7 K
4.7 K
NC
NO
The maximum distance of one line is 600 m (2,000 feet) with
AWG#22 grade conductors.
of-line resistor. This is located at the lower right on
the rear of the COSEC DOOR as shown.
SW3
Also set the number of the door controller by setting
the dip switch provided at the top right on the back of
the PANEL DOOR Controller as shown.
DIP Switch to set thePhysical RS485address of the Door
On the other hand, the COSEC DIRECT DOOR
configuration uses the DIP switches numbered 1 to 3 to
-
8/13/2019 COSEC DOOR Quick Start Booklet
14/16
Bydefault,2oftheinputsarereservedforthedoor
contact
andtherequesttoexit.Thedoorcontactisassignedto
input
DoorSTSIN+atterminals29&30,andtheassociated
request-to-exitdetectortoinputExitSWatterminals19&
20.Itisadvisabletousethesepre-assignedinputsforthe
relevantapplicationasitwouldmaketheconfiguringand
servicingofthesitesimpler.
ExternalReaderWiring
TheCOSECDOORsupportsamaximumof3readers(2
internalandoneExternal).TheExternalreaderportsupports
asinglereaderwithWiegand/Serialinterface.Tofullyutilize
Wiegandreaderport,ashielded11-conductorcable(18-22
AWG)isrequired.Themaximumrecommendedlengthof
wiringis500feetperreader.
ConnectingtheWiegandHIDR10/RW100ProxReader: TheHIDR10andRW100readerscomewiththePigtail
optionwhichhascolorcodedconductorsasspecifiedinthe
followingconnectiondiagram.
HIDR10Reader
Red
Black
Green
White
OrangeBrown
Yellow
Blue
ReaderPower
Ground
D0
D1
GreenLED
RedLED
Beeper
Hold
DataReturn
IntheabsenceofthepigtailoptionontheRW100readerthe
Referthereaderinstallationprocedureforproperpower
connection.
Step7:ConnectingtheDOORControllertotheRS-485Bus
DoorControllersarelinkedtogetherthroughtheirRS-485
LoopINandLoopOutterminalsortheEthernetportinthe
eventofusingtheTCP/IPconnectivityoption.
Themaximumcommunicationlooplengthinthecaseofan
RS485optionwiththeappropriatecableis1.2kilometers
(4,000feet)fromthelastcontrollertotheworkstation.The
RS-485communicationloopshouldbewiredwithEthernet
Category3doubletwistedpairnetworkcable(seecable
specificationsBelden1227Aorequivalent).TheRS-485loop
canoperateat115,200baud,undernormalconditions.
TolinkCOSECPANELDOORs:
1.ConnecttheincomingRS-485cabletotheLoopINAand
Bterminals(33and34respectively).Theoutgoing
RS485conductorswillconnecttotheLoopOutAandB
terminals(36and37respectively).
PANELDOORPANELDOOR PANEL
ABShield
ABShield
ABShield
RS485LoopInRS485LoopOut
A
B
ABShield
ABShield
RS485LoopInRS485LoopOut
ForthelastdoorcontrollerintheRS485loop,push
theSW3switchtotheONpositiontoenabletheend-
-
8/13/2019 COSEC DOOR Quick Start Booklet
15/16
following are the connection diagrams for the serial and the
wiegand readers.
1
2
34
5
6
7 1
2
3
45
6
7Beep
Grn
RTN+VDC
Shld
Red
Hold
GPIO1
GPIO2
OC/TmpD1
D0
GPIO3
GPIO4
1 20
T1
COMNCNO
GNDD
0D1
DATARTN
GreenLED
RedLED
Beeper
Hold
COM
Tamper
RS-232R
RS-232T
StatusLED
AlarmLED
ExitSW
COM
Rdrpwr
Terminal Strip of Door Controller
1 2 3 4 5 6 7
1234567
P1
P2
P1 P2
Terminal Strip of
RW100
Serial Reader
1
20
T1
COM
NC
NO
GND
D0D1
DATA RTN
Green LED
Red LED
Beeper
Hold
COM
Tamper
RS-232 R
RS-232 T
Status LED
Alarm LED
Exit SW
COM
Rdr pwr
Terminal Strip of Door Controller
ExternalSerial Reader
1
20
T1
COM
NC
NO
GND
D0
D1
DATA RTN
Green LED
Red LED
Beeper
Hold
COM
TamperRS-232 R
RS-232 T
Status LED
Alarm LED
Exit SW
COM
Rdr pwr
Terminal Strip of Door Controller
ExternalWiegand Reader
Connecting the red wire lead (or power lead) of a 5
VDC
reader to the 12 VDC terminal may damage the reader.
-
8/13/2019 COSEC DOOR Quick Start Booklet
16/16
P1P2
TerminalStripof
RW100
WiegandReader
ConnectingtheExternalSerialReaders:
ConnecttheMatrixCOSECReaderstotheCOSECDOOR
terminalstripasshowninthefigurebelow.Theterminalson
thebackoftheCOSECreaderunitarenumbered1through
11/15(dependingonthereader)asshownandaretobe
connectedtotheterminalstripoftheDOORusingatleasta
11conductor22AWGcable.
TerminalConnectionsforExternalReaderoptions
120
T1
COM
NC
NO
GND
D
0
D
1
DATARTN
GreenLED
RedLED
Beepe
r
Hold
COM
Tampe
r
RS-232R
RS-232T
StatusLED
AlarmLED
ExitSW
COM
Rdrpw
r
COSECREADERFPR
TerminalStripofDoorController
TheCOSECMifareandtheProximityreadermodulescanbeconnectedinthefollowingwaysdependingonthekindontheinterfacetypeofthereader.