corp brochure 2011
TRANSCRIPT
-
8/3/2019 Corp Brochure 2011
1/16
Smart Building Solutions
PROVIDING SMART BUILDING SOLUTIONS FOR OVER 25 YEARS
HVAC CONTROL ACCESS CONTROL CRITICAL ENVIRONMENTS
DURABLE FUNCTIONAL FLEXIBLE
-
8/3/2019 Corp Brochure 2011
2/16
"Through the years, American Auto-Matrix has
positioned itself as a worldwide leader in providing
Smart Building Solutions."
Our Mission is to be the premier market-driven
designer, developer, and manufacturer of Smart Building
Solutions. We are uncompromising in our quest to
provide the most comprehensive products, technology,
service, and support to the people and facilities we
serve.
OurVision is to build mutually beneficial relationships
with those who share our core values of Excellence,
Honesty, Integrity and those who focus on exceeding
the expectations of the customer.
American Auto-Matrix was founded in Pittsburgh,
Pennsylvania, U.S.A. in 1979 as Innovative Technology,
Inc. and began as a custom engineering and consulting
group manufacturing specialty electronic equipment for
its European customer base.
In 1982 the company became American Auto-Matrix,
Inc. and introduced the AI2100 Building Brain
. It wasthe first facilities automation system in the world to
offer an open communications protocol,
generation-to-generation compatibility, distributed
intelligence, direct digital control, and object-oriented
programming.
Through the years, American Auto-Matrix has positioned itself as a worldwide leader in providing Smart
Building Solutions. AAM provides solutions for HVAC, Access, Lighting, Light Process and Laboratory and
Fume Hood control as well as unparalleled support, service and training facilities.
2
Our Mission and Vision
-
8/3/2019 Corp Brochure 2011
3/16
In December 2002, American Auto-Matrix was purchased by Jordan Acquisition Group,
LLC, a group of private U.S. Investors. In 2006, the company officially became a
Service-Disabled Veteran-Owned Small Business, Woman Owned Business(SDVOSB/WOB), opening more opportunities for growth and strategic development to
an already expanding American owned company. This is directly a result of the
American Auto-Matrix philosophy to create multiple venues for our network of Solution
Integrators to succeed. Just as with our product technology, AAM wants our strategies
to be flexible to fit the needs of almost any situation.
We pledge to make the relationship with American Auto-Matrix your most valuable
asset.
Our Mission is to be the premier market-driven designer, developer,and manufacturer of Smart Building Solutions. We pledge to make therelationship with American Auto-Matrix your most valuable asset.
Our Mission and Vision
-
8/3/2019 Corp Brochure 2011
4/16
"Auto-Matrix products can be found in small-to-large
structures and throughout multiple building networks,
across the nation and around the world ."
Durable, Funtional, Flexible
BACnet is a registered trademark of ASHRAE.ASHRAE does not endorse, approve or test
products for compliance with ASHRAE standards.
Compliance of listed products to requirements
of ASHRAE Standard 135 is the responsibility
of the BACnet International. BTL is a registered
trademark of the BACnet International.
4
Durable, Functional, Flexible
-
8/3/2019 Corp Brochure 2011
5/16
000000000000000000000000000000000
222222221111111111111111111000000
American Auto-Matrix has always realized the importance of open systems architecture for Building Automation
Systems. We pioneered the concept of open protocols for building automation systems in the mid 1980s with
our Public Host Protocol (PHP) and Public Unitary Protocol (PUP) systems. AAM's philosophy of open
communication systems finally became widely accepted and specified in the industry decades later with the
emergence of BACnet and LonMark. Today American Auto-Matrix manufactures product which adheres to
these industry standards and continues to lead the way in the world of open architectures.
The American Auto-Matrix system architecture is built upon the notion of open protocols and backwards
compatibility. Our controllers have a legacy of innovation and performance - a legacy that continues today. All
of our products feature generation-to-generation compatibility, which means each new product is carefully
engineered to build on and function smoothly with its predecessors. This built-in non-obsolescence means
greater economy for owners and managers of buildings and networks where our products are in use.
AAM Unitary controllers can operate stand-alone or networked together to form a complete system. From small
stand-alone buildings, to multiple building networks, to enterprise wide applications, the AAM system offers the
same level of durability, functionality, and flexibility wherever they are found.
The American Auto-Matrix system can communicate and coordinate functions among multiple and differing
control systems within a building or network. The AAM system interfaces directly with our Auto-Flow Laboratory
and Fume Hood control system through both PUP and BACnet. In addition, our more than 30 BTL (BACnet Testing
Laboratory) listed Native BACnet controllers offer an open choice. By offering systems that not only communicate
with earlier Auto-Matrix legacy systems, but also with other control systems, the AAM advantage means much
higher cost effectiveness, system reliability, ease of installation and fast, economical upgrades to building
controls systems without vendor lock-in.
End users will find our web-enabled area control solutions powerful and intuitive. The AspectFT product family
enables users to monitor and control their building automation system in real time from anywhere in the world.
AspectFT is a Linux and Java based runtime engine found on an array of AAM devices for small to large
building control and integration applications that performs a wide variety of building management functions,
including Alarm Management, Trend Management, and Scheduling. AspectFT serves user defined web pages
that allow for the transfer of information through web browsers like Internet Explorer, Google Chrome, Mozilla
Firefox, and Apple Safari. Users can also receive critical information to their smart devices, computers, and
phones through applications like Twitter, RSS, and email. AspectFT even integrates scheduling with the
iCalendar protocol, giving the end-user the ability to schedule their building through familiar programs like
Microsoft Outlook 2007 and Google Calendar.
The power and flexibility of AAM's products, combined with backward compatibility and constant future
innovation, assures our customers that American Auto-Matrix will always be their system of choice.
Durable, Functional, Flexible
-
8/3/2019 Corp Brochure 2011
6/166
The American Auto-Matrix System Architecture provides the capability to achieve ecient and powerful Building
Automation Control. Utilizing the power of AspectFT, our system architecture provides a robust platform for
integrating multiple data sources into one unied solution. With the AspectFT control engine, you are not limited
to just one solution. As the Facilitating Technology (FT), this software platform is based upon open-standards used
within multiple industries. Designed to perform control sequences and building management routines from an
array of device platforms, AspectFT can communicate utilizing drivers such as BACnet, PUP, and Modbus. Through
varying aspects of the software, a solution can be scaled based on size and control they expect.
Engineering SoftwareStudio
FacilityLinux Based MYSQL DatabaseData storageFor server applicationsHardware provided by AAM
- BACnet IP- BACnet Ethernet- PUP IP- FTnet
- Modbus TCP- MySQL-HTTP-XML-NTP-DHCP
Ethernet PortProtocols Supported
- BACnet MSTP- PUP- Modbus RTU- and others
EIA 485 PortsProtocols Supported
NB-GPC3General Purpose I/OController
SBC-STAT3
SSB-FI1
SBC-STAT3
SSB-AO1
SSB-DO1
SSB-IOX1-1
SSB-IOX1-2SSB-IOX2-1
SSB-IOX2-2
F
NB-GPC2RTU'sAHU'sGeneral Purpose
NB-SDColor TouchscreenDisplay
NB-GPC1Chilled Water SystemsLarge AHU'sMultizone AHU'sCentral PlantGeneral Purpose
SSB-IOX1
NB-V3TVVT Application
NB-ASCePackaged Equipment
SBC-RHT
NB-GPC4General Purpose I/OController
NB-VAVVAV Boxes
F
F
NB-GPCFHC
Fume HoodControllerFHC-SDColor TouchscreenDisplay
60.3 fpm
PUPEIA-485
BACnet MS/TP EIA-485
STATbus Protocol
Ethernet / Internet
AM System Architecture
Linux BasedMYSQL DatabaseData storageFor large server applicationsHardware qualified by AAM
Enterprise
-
8/3/2019 Corp Brochure 2011
7/16
Third PartyBACnet IP Workstation***
EIA-485 Ports
Protocols Supported:
PUP (Public Unitary Protocol)
BACnet MS/TP
PHP (STAR)
Modbus
And Others*
Ethernet Port
Protocols Supported:
BACnet IP
BACnet Ethernet
Modbus TCP
SNMP
OPC FTT-10A
LonWorks Network
Port (1)
Note:This System Architecture represents multiple
design scenarios. For more detailed architectural
information please reference our System
Architectures brochure. As with all architectural
representations, functionality and performance are
dependent upon controller capabilities and
Integra Workplace
Web Browser Hand-held device
Web Browser
SBC-GPC3General Purpose I/OController
SBC-STAT3
SSB-FI1
SBC-STAT3
SSB-AO1
SSB-DO1
F
SBC-GPC2RTU'sAHU'sGeneral Purpose
SBC-SDColor TouchscreenDisplay
SBC-GPC1Chilled Water SystemsLarge AHU'sMultizone AHU'sCentral PlantGeneral Purpose
SSB-IOX1
SBC-V3TVVT Application
SBC-ASCePackaged Equipment
SBC-RHT
SBC-VAVVAV Boxes
F
F
SBC-GPCFHCFume HoodController
FHC-SDColor TouchscreenDisplay
60.3 fpm
SOLO-DX1Chilled Water SystemsLarge AHU'sMultizone AHU'sCentral PlantGeneral Purpose
SOLO-GX1
RTU'sAHU'sGeneral Purpose
SOLO-MC1Terminal Equipment
SOLO-GC1Small AHU'SRTU'sUnit Ventilators
SSB-IOX1-1
SSB-IOX1-2
SSB-IOX2-1
SSB-IOX2-2
AAM System Architecture
-
8/3/2019 Corp Brochure 2011
8/16
Flexibility through Proven Methodologiesand a Widely Accepted Open Protocol
For decades the laboratory control engineering
community has been forced to select between
various control philosophies for fume hoods when
choosing a product line. These include open loop
control utilizing calibrated pressure independent
venturi valves, hood pressure schemes, and closed
loop control based on actual face velocity flowmeasurement.
With the Auto-Flow Critical Environments product
line, the choice is easy. We offer safe and effective
means for accurate and precise control of fume
hood applications through controls and peripherals
designed to meet your specification needs.
Through patented technologies as well as other
methodologies, combined with Native BACnet
control, installations can connect seamlessly to any
American-AutoMatrixHVACcontrol system,aswell as
most Native BACnet compliant system. Installations
can also utilize either Face Velocity measurement or
Sash Areacalculation methods. This, in combination
with a full color touch-screen display, which offers
unique set-up capabilities, as well as visible and
audible multi-stage alarming, creates a solution that
offers flexibility found in no other product line.
Auto-Flow provides solutions that encompass
the needs of all parties involved in the Critical
Environment process. This is achieved through
providing a solution that not only communicates in
a widely accepted open protocol, but offers a level
of flexibility in which multiple familiar and proven
methodologies are available. This, in turn, createsan environment whereby retrofits, new installations,
and additions can be achieved without increasing
the learningcurve or introducingunfamiliarmethods
or technologies, increasingsafetyaswell assavings.
Only Native BACnet solution in the industry
Unprecedented flexibility in fume hood andlaboratory control
A revolutionary level of operator interface
Integrated building management flexibility using
Native BACnet system; proprietary gateway not
required
Familiar, trusted, and proven methodologies
8
Auto-Flow Critical Environments
-
8/3/2019 Corp Brochure 2011
9/16
FV
COM
EXF
AVP
COM
EMG
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(19)
(20)
(21)
(22)
SP1
COM
SP2
SP3
COM
SP4
FVEXF
AVPEMG
SP1SP2
+24 VDC OUTCOMMON
CF -CF+
CASCADEFLOW
RESET
(0607a) PATENTPENDING
R X T X PE BE
N+ N- N+ N-
INPUTSMADE IN U S A
POWER SUPPLY STATUS
STATBUS BYTE ERROR
STATBUS PROTOCOL ERROR
+3.3V+5V
+24V
MAINPOWER
CONTACTCLOSED
K1 ALM
DIGITAL OUTPUTS
X124VACIN
EXD
COM
CFO
COMEXD
SSB ACTIVITY
IOX1 DISPLAYONLY IOX3
MAIN PROCESSOR
IO PROCESSOR
I V R ANALOG OUTPUTS
AO STATUS
X2TERM
Product Designation:
(TB1)
(TB2)
(TB4)
TB6
(TB5)
RS-485
(23) (24) (25) (26) (27) (28) (29) (30) (31) (32) (33) (34) (35) (36) (37) (38) (43) (44)
X1X2
TB9 TB10 TB12
(45)
(46)
(47)
(48)
(57)
(58)
(69)
(70)
(TB13)
(TB15)
(TB17)
24VACOUT
80M7,OPEN ENERGYMANAGEME NTEQUIPMENT.SeeReferenceManualNo.1E-04-00-0xxxfor Instructionsfor use
ELECTRICALRATINGS:PowerInputs:Class2
24VAC50/60HzNominal 4.17Amaximum1.85APTC Protection
PowerOutputs:Class224VAC1.3A maximum1.35APTC Protection24VDCOut .15Amaximum.2APTC ProtectionIOX24VACOUT.9APTC ProtectionTotal
TriacOutputs:Class21A30VAC maximumSignalInputs/Outputs: Class2
30VDCmaximumCommunicationSignals: Class2
EIA-485,5VDC maximumSSB,12VDC 50mAmaximum
ENVIRONMENTRATINGS:Temperature:
0to50CHumidity:
0to80%RH non-condensing
NET TOOL
UR
ThisdevicecomplieswithPart15 ofthe FCCRules.
Operationofthisequipmentissubject tothefollowing
twoconditions:1)Thisdevicemay notcauseharmful
interference,and2)Thisdevicemust acceptany
interferencereceived,includinginterferencethatmay
causeundesiredoperation.
Caution:ImproperWiring willcause damage.Refer toManual
JUMPERCONFIGURATION
[TYPICAL UI]
I: 0-20mA
V: 0-10VDC
R: 0-250K ohm
I V R
TB7 TB8
SSBCOMX1X2
ACOUT
SSBCOMX1X2
ACOUT
SSBCOMX1X2
ACOUT
V: 0-10VDCI: 0-20mA
JUMPER CONFIGURATION[TYPICAL FOR AO]
V I
V I
UseCopperConductorsOnlyCaution:TerminalBlock Torque3Inch-pounds maximum
SP3SP4
SBC-GPCFHC1
NB-GPCFHC1
SBC-GPCFHC2
NB-GPCFHC2
CRITICAL ENVIRONMENTS
Fume Hood Controller
FHC-SD
Native BACnet control utilizing American Auto-Matrix state-of-the-art GPCtechnology
Complies with ANSI/ASHRAEStandard 110-1995
32 bit microprocessor utilizing tunable high speed PID ControlAlgorithms
PIDcontrol, loop cycles every50ms, for exhaust damperoutput
Inputs and Outputs updated 20 times per second
Stand Alone or Networked operation
Reliable high-speed communication over twisted pair (EIA485)wire; up to 115.2k Baud (note: exceeds BACnet specification)
Controls using measured Face Velocity or Sash Position
Pre-programmed function blocks
Configurable set-points, multistage alarms, and alarm delays
SeparateFlow Totalization Networkformultiplehoodvolumetricoffset flow control of laboratories
18 bit input resolution enables use of various measuredvariable inputs such as sash position, face velocity, hood staticpressure, or side wall velocity
Emergency saving setback mode via sensor input or network
NB-GPCFHC
Custom icon-based,256 Bit Color LCDTouchScreen Local UserInterface for displaying and modification of system informationspecific to the NB-GPCFHC
Multi level numerical password based control
High Speed ARM Processor
8MB RAM
Comes standard with SD/MMC card socket accessible byremoving casing giving the ability to:
Flash program upgrades
Flash hood set-up to multiple displays
Store debugging information for multiple hoodapplications
Hood calibration and adjustments through touch-screeninterface without need for external software
Programmable Alarming:
Cautionary alarms of several parameters-flashes yellow with specific audible alarmsequence; mutable
Extreme alarm- flashes red with specificaudible alarm sequence; mutable
Emergency activation with password protecteddeactivation
Set-up and display English or Metric units
Chemical resistant Kydex plastic case, mountable on both USand Euro switch boxes; available with IP44 protection
Alarms HoodSetpoints
Inputs
+
Outputs Configure Hood Setup
Diagnostics Logout Home
Face Velocity
60.3 fpm
Face Velocity
85.1 fpmMenu Screen
Default Home Screen(In Alarm Mode)
Auto-Flow Critical Environments
-
8/3/2019 Corp Brochure 2011
10/16
The Face Velocitymethod represents a complete engineered solutiondesigned to accurately control face velocity through measurement in the
plane of the sash. Conforming to ASHRAE Standard 110, this method
combines ultra Low Pressure Sensors, high accuracy Air Velocity Sensors,
BACnet DDC control, high speed Electronic Actuators, and precision
Control Dampers, to create a safe and energy ecient critically controlled
environment. The patented Auto-Flow Face Velocity method is the only
method that actually oers complete closed loop control. Auto-Flow Patent
Numbers: 5,764,579; 6,272,399; 5,920,488; 5,946,221.
Face Velocity Method
Press For Emergency
Main Menu
Face Velocity
100.1 fpm
Fume Hood Display 272 X 480 pixel, color LCD display
Icon driven touch screen interface
Audible and visual alarm
indications
Monitor and modify inputs and
control parameters
Displays real time fume hood
operating conditions
Hood set-up routines built in with
no need for secondary software
Electronic Damper
Actuator High speed 1.5 second traveltime through 90 rotation Exclusive long-life design Non-constant internal controlfeedback Capacitance-based fail safeposition control
Precision Damper Assembly High precision PVC control damper with stainless steel damper blade
High turn down ratio, low pressure drop
Linear control through DDC controller
Long life, high speed actuator provides fast, precise movement
High speed Damper Actuator with a 90 degree end-to-end stroke
time of 1.5 seconds
Face Velocity Transmitter Ultra low dierential pressure
sensing of 0.0015 in. w.c. full
scale
Slack Membrane with optical
sensing
Fast 100mS response time
Used with airfoil pitot for face
velocity measurement
Airfoil Pitot Instantaneous, direct
measurement of actual face
velocity
Applicable to various sash
congurations
Measurement out of
contaminated air stream
Responds to obstructions to
hood face and external pressure
variations
P atentP endingMadeintheU.S .A.(0608a)
TheAmericanAuto-Matrixlogoisaregisteredtrademark of
AmericanAuto-Matrix,LLC.AmericanAuto-Matrix,LLC.2006
CRITICAL ENVIRONMENTS
Fume Hood Controller
SBC-GPCFHC1 NB-GPCFHC1 SBC-GPCFHC2 NB-GPCFHC2
*
BACnet Fume
Hood Controller 150mS response time
18-bit input resolution
Dedicated full color display
Native BACnet
PID control of face velocity
(optional)
*
Instantaneousdirect measurement of the actuface velocity taken at the plane of sash througthe use of the patented Airfoil Pitot
High speed tunable PID control algorithms
Complete closed loop control
Constant display of actual face velocity
Compatible with horizontal, vertical, orcombination sash conguration
Responds to obstructions of hood face
Face Velocity measurement not hindered large apparatus left in the hood
System corrects for high molecular weightgases
Single blade, high precision Control Dampermanufactured from rigid PVC and stainlesssteel
Face Velocity
10
Auto-Flow Critical Environments
-
8/3/2019 Corp Brochure 2011
11/16
Flixible by DesignThe Sash Position method represents a widely accepted methoddesigned to control face velocity based on calculations congured directly
into the controller. Face velocity is controlled by calculating the ow
area based on sash position and then controlling a calibrated air valve.
Secondary ow feedback is also possible. The Sash Position Method
uses polymer coated string pots, a linear airow valve, and a dierential
pressure switch to regulate face velocity.
Sash Position Method
Sash Position Sensor Compact, durable, longcable life Withstands impacts andchemicals Designed for high-cycleapplications
BACnet Fume Hood Controller 150mS response time
18-bit input resolution
Dedicated full color display
Native BACnet
PID control of face velocity (optional)
*
P atentP endingMadeintheU.S .A.(0608a)
TheAmericanAuto-Matrixlogoisaregisteredtrademark ofAmericanAuto-Matrix,LLC.AmericanAuto-Matrix,LLC.2006
CRITICAL ENVIRONMENTS
Fume Hood Controller
SBC-GPCFHC1 NB-GPCFHC1 SBC-GPCFHC2 NB-GPCFHC2
Press For Emergency
Main Menu
Face Velocity
100.1 fpm
Fume Hood Display 272 X 480 pixel, color LCD display
Icon driven touch screen interface
Audible and visual alarm
indications
Monitor and modify inputs and
control parameters
Displays real time fume hood
operating conditions
Hood set-up routines built in with
no need for secondary software
Venturi Air Valve Available in a range of sizes
Stainless steel control rod
Baked phenolic P403 Heresite
powder coating
Zero leakage model available
Teon (optional)
Venturi Valve is a factory calibrated
device
Electronic Damper Actuator
High speed 1.5 second travel timethrough 90 rotation
Exclusive long-life design
Non-constant internal control
feedback
Capacitance-based fail safeposition control
Sash PositionFace velocity calculated by congured sashposition; also considers bypass ow and hood
leakage
Complete closed loop control based on exhaust
ow is made possible using secondary owmeasurement (optional)
High speed tunable PID control algorithms; thefastest response time in the industry
Auto-Flow Critical Environm
-
8/3/2019 Corp Brochure 2011
12/16
What truly separates one company from another is the commitment to developing a strong relationship with
its partners. Our industry is built upon it, and it is those
relationships that foster success. American Auto-Matrix sets
the standard from which all others are measured when itcomes to building strong, mutually beneficial relationships
with our Solution Integrator (SI) partners. Our technical
support, training, marketing and dealer programs
complement our building automation systems and
complete the Smart Building Solution.
AAM Technical Support
American Auto-Matrix has a full support staff available towork with our network of Solution Integrators. Our
technicians are focused on providing realistic solutions with
each and every call received. AAM guarantees a 24-hour
response to technical inquiries and works diligently to solve
every issue.
Our technical support team has the resources to resolve
issues that range from simple questions such as what kind
of wire should be used, to application assistance across thelife of a project. Technical support is available to assist in
the setup and programming for the complete line of
American Auto-Matrix products.
Our staff also supports the web tools we offer direct from
the Internet. All of our Solution Integrators are registered for
our AAM Toolbox. This is an electronic toolbox and
web-board that is available 24-hours a day through our
secure web-site. The toolbox contains information that theSolution Integrators may find useful such as Engineering drawings, custom programs, documentation,
technical tips, and other files that help reduce the overall engineering, programming and commissioning of
projects in the field.
se
ts
itps
al
s
nd
tour
ith
ur
ve
ve
nd
hein
o
m
or
nd
ur
he
12
The AAM Advantage
-
8/3/2019 Corp Brochure 2011
13/16
Educational Services
Education and training are the stepping-stones to the
success of any new Solution Integrator or end-user. The
Training Center for Smart Building Solutions, located at
the American Auto-Matrix headquarters in Export, PA, is a
state-of the art training center that offers a wide range of
workshops surrounding the AAM product line.
The training center offers theoretical and hands-on
workshops that allow students to become competent
with the use of AAM products and technologies. The
workshops are not only provided for the success of the
Solution Integrator, but also for the success of their customers as well. End-users are welcome and receive
the same level of instruction as the Solution Integrators.
Also included in the AAM training repertoire is the new AspectFT & Matrix Network Area Controller on-line
training course. For years the training center has exclusively offered on-site and off-site training, but now is
offering this web-based workshop. Look for more classes to follow.
Sales & Marketing Support
The American Auto-Matrix / Solution Integrator relationship is a co-operative process between many people.
We believe the success of any relationship is predicated on this cooperation and strive to do our part.
Our Sales and Marketing departments are
committed to providing support to all of
our Solution Integrators. The co-operative
sales and marketing efforts available
include visits from corporate personnel to
your customers, engineers, and end-users,
project reference listings, custom
company store items, links to our website,
lunch and learn sessions, and sales calls.
American Auto-Matrix also offers the
Co-Op Marketing plan. AAM's Co-Op
Marketing is an opportunity for Solution
Integrators to customize AAM promotional materials to reflect their business and image. American
Auto-Matrix will work with Solution Integrators to develop custom content to create a cohesive marketing
presentation.
Co Op Marketing
-
8/3/2019 Corp Brochure 2011
14/16
-
8/3/2019 Corp Brochure 2011
15/16
Smart means our products are designed to think like people, not like machines. We continually strive to design
and develop technologies for the building automation industry which change the way people think about their
buildings. Our products provide comfort, safety, and cost effective design for the future.
Building originates from our focus on relationships. The success of each project is based on the relationships
that are developed with our Solution Integrators and their customers. This relationship is key to how well our
products serve the needs of people.
Solutions reflects our many technological innovations including the first to offer direct digital control (DDC) and
open communication protocols, generation-to-generation compatibility, patented laboratory and fume hood
controls, and access control systems, as well as unparalleled support and service to our Solution Integrators.
AAM installations include places such as the American Museum of Natural History where exhibits such as
Leonardo da Vinci's Codex Leicester: A Masterpiece of Science required controls to regulate climate to preserve
the last privately held manuscript of Leonardo da Vinci; and the Zeiss Star Projector, one of the most advanced
projectors in the world, that utilizes AAM controls to regulate temperature and humidity. Installed sites also
include the University of Maryland, ranked by the Carnegie Foundation in the top tier of national research
universities, which uses the Auto-Flow laboratory control system because of its unique capability to provide a
total fume hood control solution that "allows for maximum efficiency and increased energy savings while
providing precise temperature, humidity, and pressure control throughout the day for students and faculty alike." *
Our American made products, approach to open systems, commitment to backwards compatibility, and
continuous technological innovation, coupled with the best customer service and support, makes American
Auto-Matrix the premier institution for Smart Building Solutions
* University Known for IT Experiences Advantages of Single Source Controls. Engineered Systems Magazine: Copyright 2008 AAM Installations: Stating at the top right (CCW):Independence Blue Cross Hospital, New York City PubliLibrary, St. Bonaventure University, Anglo Platinum,Haverford College, University of Maryland, AmericanMuseum of Natural History
Smart Building Solutions
-
8/3/2019 Corp Brochure 2011
16/16
Corporate Headquarters: One Technology Lane Export, PA 15632 Phone: 724-733-2000 Fax: 724-327-6124
American Auto-Matrix is a Service-Disabled Veteran-Owned Small Business / Woman-Owned Business (CCR Cage #4LL80)
Warning: Appropriate safety precautions must always be taken when operating or maintaining equipment connected to any American Auto-Matrix product or otheLicensed Materials or Hardware. AAM assumes no responsibility or liability for any injuries or damage to any persons or property resulting from the use of theseproducts. As always, these products should be used in the manner they are intended.
American Auto-Matrix, the American Auto-Matrix logo, the Rocket A and Smart Building Solutions are registered trademarks of American Auto-Matrix. Windows is a registeredtrademark of the Microsoft Corporation. Modbus is a trademark of Schneider Electric. OPC is a trademark of the OPC Foundation. BACnet is a registered trademark of ASHRAEBTL is a registered trademark of BACnet International. Niagara and NiagaraAX Framework are registered trademarks of Tridium, Inc. MODBUS, MODBUS RTU, and MODBUS TCP/IP are registered trademarks of Schneider Electric. Java, JavaScript, MySQL and JavaBeans are either registered trademarks or trademarks of Oracle Corporation, Inc in theUnited States and other countries; Google is a trademark of Google Inc.; Microsoft, Windows, Windows NT, Microsoft Excel are registered trademarks of Microsoft; Rhino is anopen-source implementation of JavaScript and is managed by Mozilla. Mozilla is a registered trademark of the Mozilla Foundation; Linux is a registered trademark oLinus Torvalds. Apple and iCal are registered trademarks of Apple, Inc. The Twitter name, logo, Twitter T, Tweet, and Twitter blue bird are trademarks of Twitter, Inc. in theUnited States and other countries. BACnet is registered trademark of ASHRAE.
2011 American Auto-Matrix.(Part no. IE-06-00-0002)
www.aamatrix.com
Smart Building Solutions
At American Auto-Matrix, we believe in providing Smart Building Solutions. We chosethis tag line deliberately and thoughtfully, and we take it seriously. Smart means ourproducts are designed to think like people, not like machines. Building originates fromour focus on relationships. Solutions reflects our many technological innovations and
unparalleled support.
Made in the U.S.A.
American Made American Owned
AAM Products and Systems are manufactured and installed under one or more of the following US Patents and/or others that may apply. 5,481,919; 5,764,579; 6,272,399; 5,402,687; 5,415,583