    112007NOV152007NOV15NEC ConfidentialNEC Confidential

    PASOLINK NEO & NEO/cRoadmap & Product Line Up

    For Banglalink

  • 5/26/2018 Copy of Paso Neo Presentation

    2/49

    222007NOV152007NOV15NEC ConfidentialNEC Confidential

    Equipment Menu (PASOLINK NEO)Equipment Menu (PASOLINK NEO)

    Modulation256QAM

    128QAM

    64QAM

    32QAM

    16QAM

    8PSK

    4PSK

    0 3.5 7.0 14.0 28.0 40.0 56.0 [MHz]

    Adjacent CH Spacing

    5E1 10E1 20E1

    5E1 10E1 20E1 40E1

    100MB/48E1

    STM-1

    PASOLINK NEO

    (Standard version)

  • 5/26/2018 Copy of Paso Neo Presentation

    3/49

    332007NOV152007NOV15NEC ConfidentialNEC Confidential

    1.1. EquipmentEquipment MenuMenu

    Interface (NEO)

    PDH : 5/10/20E1, 4PSK

    5/10/20/32/40E1, 16QAM

    48E1, 32QAM

    1/2E3, 4PSK/16QAM

    SDH : STM-1, 128QAM

    2xSTM-1, 128QAM/XPIC

    Ethernet : 10M/20M/40Mbps, 4PSK

    10M/20M/40M/80Mbps, 16QAM

    100Mbps, 32QAM

    100M/50M or 75M/75Mbps, 128QAM

    RF Frequency

    NEO : L6/U6/7/8/10.5/11/13/15/18/23/26/28/32/38/52GHz

    2x40E1=>80E12x48E1=>96E1

    PDH XPIC

  • 5/26/2018 Copy of Paso Neo Presentation

    4/49442007NOV152007NOV15NEC ConfidentialNEC Confidential

    PASOLINK NEO IDU MODULESPASOLINK NEO IDU MODULES

    1

    2

    3

    4 5

    7

    6

    PASOLINK NEO IDU RACK AND MODULES

    NO.

    1

    2

    3

    3

    4

    4 H2960 [B] STM-1 INTFC Optical (S 1.1) SDH Main Slot

    4 H2960 [C] STM-1 INTFC Optical (L 1.1) SDH Main Slot

    4 H2965 [C] LAN / WS INTFC SDH Main Slot (2 Port LAN)

    5 H2965 [C] LAN / WS INTFC SDH Main / Sub-Slot (WS/SC LAN)

    4 H3021 GbE INTFC SDH Main Slot

    5 H2960 [B] STM-1 INTFC Optical (S 1.1) SDH Sub-Slot (APS)

    5 H2960 [C] STM-1 INTFC Optical (L 1.1) SDH Sub-Slot (APS)

    5 H2965 [A] LAN / WS INTFC SDH Sub-Slot (WS/SC LAN)

    6 H2980 [B] 16E1 E/W 2 Way DXC INTFC PDH With 2 Port LAN

    5 H2965 [B] LAN / WS INTFC SDH Sub-Slot (WS)

    6

    6

    6 H3010 E3 INTFC PDH Two E3, up to 8 WS

    6 H3020 4P LAN INTFC PDH With E1s

    7

    CODE NO. MODULE NAME REMARKS

    H2931 RACK COMMON

    H2940 MODEM COMMON (1+0)

    H2940 MODEM COMMON (1+1)

    H3040 DC-DC CONV COMMON (1+0) (with EHG ODU)

    H2960 [A] STM-1 INTFC Electrical SDH Main Slot

    H2980 [A] 16E1 INTFC + 2 Port LAN PDH

    H3000 48E1 INTFC PDH

    H2950 CTRL COMMON

  • 5/26/2018 Copy of Paso Neo Presentation

    5/49552007NOV152007NOV15

    NEC ConfidentialNEC Confidential

    Replaceable Interface Cards

    Interface cards

    Control CardModem

  • 5/26/2018 Copy of Paso Neo Presentation

    6/49662007NOV152007NOV15

    NEC ConfidentialNEC Confidential

    Replaceable Interface Cards

    1. 16E1 + 2 Port LAN

    5. 1xE3/2xE3 + 2port LAN

    2. 48E1

    3. 4 Port LAN + 4/8E1

    4. 32E1 + 2 Port LAN

    6. STM-1(opt)

    7. STM-1(elec)

    8. 2 Port LAN or WS(E1)/LAN

    9. 1 Port GbE

    10. 16E1+2 Port LAN with DXC

    11. Nodal (expandable)

    12. Nodal (expandable: STM-1 termination)

    13. VLAN (4port FE+4E1)

    14. VLAN (3port FE+1port GbE+1E1)

    [NEO Standard]

    [VLAN][Standard Nodal]

    Just released

    2008 1Qust released

  • 5/26/2018 Copy of Paso Neo Presentation

    7/49772007NOV152007NOV15

    NEC ConfidentialNEC Confidential

    32E1 & 2PORT LAN INTFC FOR PDH

    80/96E1 PDH XPIC SYSTEM

  • 5/26/2018 Copy of Paso Neo Presentation

    8/49

    882007NOV152007NOV15NEC ConfidentialNEC Confidential

    32E1 + LAN32E1 + LAN

    E1 x 32 Channels (MDR68(68pin) x 2, 75/120 ohm S/W selectable)

    10/100BASE-T(X) x 2 Ports (RJ-45 x 2, Auto-Negotiation / Auto-MDI/MDIX)

    System : PDH

    N/AN/AO

    E1 Protection (SNCP)2Way DXCTERMINAL

    Transmission Capacity & Modulation

    10M 20M 40M 80M 100M 156M

    QPSK/16QAM 16QAM 32QAM 128QAM

    O O O O O N/A

    Mapping Interface Speed

    MAIN SC 10M 100M 1000MRMON

    O O O O N/A O N/A

    VLAN

    LAN Specification

    .

  • 5/26/2018 Copy of Paso Neo Presentation

    9/49

    992007NOV152007NOV15NEC ConfidentialNEC Confidential

    PDH XPIC (CCDP)PDH XPIC (CCDP)

    FeaturesFeaturesSuper PDH

    80E1/ 16QAM in 28MHz band width

    96E1/ 32QAM in 28MHz band width

    Good XPIF (Cross Polarize Interference Improvement Factor)

    16QAM 15 dB (1dB degradation C/I 25dB

  • 5/26/2018 Copy of Paso Neo Presentation

    10/49

    10102007NOV152007NOV15NEC ConfidentialNEC Confidential

    XPIC ConfigurationXPIC Configuration

    Two ODUs and Dual polarized Antenna

    Vertical

    Horizontal Cancel and Control signals

    40/48E1

    28 MHz

    Vertical(11-38GHz Direct Mount Antenna Available.

    6-10GHz feeder connect ion between Antenna

    and ODU)Horizontal

    Two IDUs 40/48E1

  • 5/26/2018 Copy of Paso Neo Presentation

    11/49

    11112007NOV152007NOV15NEC ConfidentialNEC Confidential

    80/96E1 PDH XPIC System80/96E1 PDH XPIC System

    1+0 IDU40/48E1 ODU

    f1

    ODU

    f1

    1+0 IDU40/48E1

    V

    H

    1+0 IDU40/48E1ODU

    f1

    ODU

    f1

    1+0 IDU40/48E1

    VH

    HV

    -H

    -V

    V

    H

    V

    H

    Cancellation

    XPIC System configuration

    TX SIDE RX SIDE

    40E1/16QAM or 48E1/32QAM40E1/16QAM or 48E1/32QAM

    28MHz

    40/48E1

    40/48E128MHz

    40/48E1

    IDU ODU

    40/48E1

    40/48E1

    40/48E1

    PDH XPIC S t P tPDH XPIC S t P t

  • 5/26/2018 Copy of Paso Neo Presentation

    12/49

    12122007NOV152007NOV15NEC ConfidentialNEC Confidential

    PDH XPIC System ParameterPDH XPIC System Parameter

    System parameters are the same as normal equipment

    Frequency band 6-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28GHz 32GHz 38GHz

    Range(GHz) 5.925-8.5 10.15-11.7 12.75-13.25 14.2-15.35 17.7-19.7 21.2-23.6 24.25-27.0 27.5-29.5 31.8-33.4 37.0-40.0

    Tx pow er(dBm)

    32QAM 25 21 21 21 19 19 18 18 17 14.5

    16QAM 26 21.5 22.5 22.5 22 22 20 18 17 14.5

    Receive r thre shold(dBm ) at 10-6 BER

    100M/32Q -75.5 -74.5 -74.5 -75.0 -75.0 -75.0 -74.5 -74.5 -73.0 -73.0

    80M/16Q -77.0 -76.0 -76.0 -76.5 -76.5 -76.5 -76.0 -76.0 -74.5 -74.5

    System Gain(dB) at 10-6 BER

    100M/32Q 100.5 95.5 95.5 96.0 94.0 94.0 92.5 92.5 90.0 87.5

    80M/16Q 103.0 97.5 98.5 99.0 98.5 98.5 96.0 94.0 91.5 89.0

    Regarding QPSK, CCDP can be applied without XPIC.

    NEO/

  • 5/26/2018 Copy of Paso Neo Presentation

    13/49

    13132007NOV152007NOV15NEC ConfidentialNEC Confidential

    NEO/c

    Main FeaturesMain Features

    Common platform design (PDH, LAN)

    16E1 + 2FE INTFC Card

    Bitrate Free10MB/ 20MB/ 40MB (Same Module)

    Modulation Selectable

    4PSK/ 16QAM

    Compact size/ Low power

    IDU :1+0/1+1 @ 1U without FAN , ODU : 2 LTR(13G~)

    Bandwidth and Modulation Free ODU

    Coverage from 5E1 to 16E1 or from 10M to 40Mbps.

  • 5/26/2018 Copy of Paso Neo Presentation

    14/49

    14142007NOV152007NOV15NEC ConfidentialNEC Confidential

    1+0 Equipment Configuration1+0 Equipment Configuration

    ODU(13G-38G)

    CTRL

    1U

    IDU Dim. :482x44x190mm

    vs PASO V4 : 76%

    vs NEO standard : 84%

    IDU E1 Interface

    ALM INTFC (Opt ion)

    DC -48VSC/ALM

    Fuse (same as V4/PASO+)

    LCT

    1+0 @ 1U

    Bitrate free (5E1 16E1)

    Modulation free (4PSK, 16QAM)

    ODU(7G/8G)

    1+1 Equipment Configuration1+1 Equipment Configuration

  • 5/26/2018 Copy of Paso Neo Presentation

    15/49

    15152007NOV152007NOV15NEC ConfidentialNEC Confidential

    1+1 Equipment Configuration1+1 Equipment Configuration

    INTFC Card 16E1 INTFC only

    MD UNIT (for NEO/c)CTRL Card (for NEO/c)

    1U

    ODU / Hybrid

    IDU

    IDU Dim.482x44x230mm1+0 exp / 1+1 @ 1U

    Bitrate free (5E1 16E1)

    Modulation free (4PSK, 16QAM)

    same as NEO standard

    vs PASO V4 : 92%

    NEO/c IDU MenuNEO/c IDU Menu

  • 5/26/2018 Copy of Paso Neo Presentation

    16/49

    16162007NOV152007NOV15NEC ConfidentialNEC Confidential

    NEO/c IDU MenuNEO/c IDU Menu

    Type System

    Config.

    Capacity Modulation LAN Form

    1-1 1+0 5xE1 Fix 4PSK Fix N/A

    1-2 1+0 5/10/16 xE1

    Selectable

    4PSK Fix N/A

    1-3 1+0 5/10/16 xE1

    Selectable

    4PSK/16QAM

    Selectable

    N/A

    2-1 1+1

    /1+0 exp.

    5/10/16 xE1

    Selectable

    4PSK Fix Up to

    40MB

    2-2 1+1

    /1+0 exp.

    5/10/16 xE1

    Selectable

    4PSK/16QAM

    Selectable

    Up to

    40MB

    *1) e/w Alarm Interface Option

    *1)

    *1)

    *1)

    ODU Menu (Comparison with V4/Mx)ODU Menu (Comparison with V4/Mx)

  • 5/26/2018 Copy of Paso Neo Presentation

    17/49

    17172007NOV152007NOV15NEC ConfidentialNEC Confidential

    ODU Menu (Comparison with V4/Mx)ODU Menu (Comparison with V4/Mx)

    o:released -:N/A

    Current Menu L6 U6 7 8 10 10.5 11 13 15 18 23 26 28 32 38 52

    - - - - - - -

    - - - - - - - -

    New Menu

    - - - - - - - -NEO/c

    Mx

    NEO standard

    V4

    7G/8G 13G -- 38G

    SUB Band :same as V4 ODU

    Application of NEO standard/compactApplication of NEO standard/compact

  • 5/26/2018 Copy of Paso Neo Presentation

    18/49

    18182007NOV152007NOV15NEC ConfidentialNEC Confidential

    Application of NEO standard/compactApplication of NEO standard/compact

    NEO/cNEO/c

    NEO standardNEO standard5E1-16E1

    4PSK/16QAM

    5E1-48E1 / STM-1 (XPIC)

    4PSK-128QAM

    Fixed Upgrade

    with LAN NEO standardODU

    1+1,1+0 exp.

    NEO compact

    For future upgrade

    without LAN

    NEO standard IDU

    1+1,1+0 exp.

    1+0 fixed

    NEO compact

  • 5/26/2018 Copy of Paso Neo Presentation

    19/49

    19192007NOV152007NOV15NEC ConfidentialNEC Confidential

    NECs Nodal Radio

    IDU Type 2Way Fixed Type 2Way Expandable Type 6Way Box Type

    Max. Air Capacity 80Mbps (40E1) 100Mbps (48E1) 100Mbps (48E1)

    155Mbps (STM-1)

    310Mbps (2xSTM-1)

    Interface E1 16ch 16ch / unit 32ch / card

    STM-1 (opt)

    STM-4 (opt)

    LAN

    Cooling Natural Forced (FAN) Forced (FAN)

    N.A 1ch / unit 1 ~ 4ch / card

    N.A N.A 1ch / card

    No. of branching 2-Way / Rack 2-Way / IDU(max.8-way / 4IDU)

    6-Wa y /Rack(max. 12-Way / 2Rack)

    2xFE

    N/A

    1U

    N.A 4FE + 1GbE

    Redundant system of DXC N/A Available

    Unit Size 1U x 4 + Fan unit 6U ~ 8U

    12-Way

    8-Way (Max.)

    RCPMCP

    MODEMMODEM

    MODEMMODEM

    MODEMMODEM

    C ONV C ON V

    APAP

    APAP

    C ONV C ON V

    C ONV CO NV

    P-INF

    AUX/SV

    DXCDXC

    P-INF

    FAN

    FAN

    RCPMCP

    MODEMMODEM

    MODEMMODEM

    MODEMMODEM

    C ONV C ON V

    APAPAPAP

    C ONV C ON V

    CO NV CO NV

    P-INF

    AUX/SV

    DXCDXC

    P-INF

    FAN

    FAN

    RCPMCP

    MODEMMODEM

    MODEMMODEM

    MODEMMODEM

    C ONV C ON V

    APAP

    APAP

    C ONV C ON V

    CO NV CO NV

    P-INF

    AUX/SV

    DXCDXC

    P-INF

    FAN

    FAN6-Way2-Way

    2Way Expandable Type2Way Fixed Type 6Way Box Type

    2 W NODAL PDH CROSS CONNECT

  • 5/26/2018 Copy of Paso Neo Presentation

    20/49

    20202007NOV152007NOV15NEC ConfidentialNEC Confidential

    2 Way NODAL - PDH CROSS CONNECT

    Max. 80Mbps(40E1)

    Air Capacity

    16E1+LAN

    2x8E1(D-Sub)

    Dir-A

    A) Term DXC

    D/I for A

    DXC

    Dir-A

    A) Term DXC

    D/I for A

    DXC

    DXC

    Dir-A

    B) 2way-StarDir-B

    D/I for AD/I for B

    Dir-A >= Dir-BDXCDXC

    Dir-A

    B) 2way-StarDir-B

    D/I for AD/I for B

    Dir-A >= Dir-BDXC

    Dir-A

    C) 2way-tree

    Dir-B

    D/I for A

    Rep

    Dir-A > Dir-BDXC

    Dir-A

    C) 2way-tree

    Dir-B

    D/I for A

    Rep

    Dir-A > Dir-BDXC

    Dir-A

    D) 2way-Rep

    Dir-BRep

    Dir-A = Dir-B

    D/I = 0

    Dir-A

    D) 2way-Rep

    Dir-BRep

    Dir-A = Dir-B

    D/I = 0

    2 WAY -TREETERMINAL - DXC

    2 WAY -STAR 2 WAY -REPEATER

    EQUIPMENT SETUPEQUIPMENT SETUP PDH XC INTFCPDH XC INTFC

  • 5/26/2018 Copy of Paso Neo Presentation

    21/49

    21212007NOV152007NOV15NEC ConfidentialNEC Confidential

    EQUIPMENT SETUPEQUIPMENT SETUP PDH XC INTFCPDH XC INTFC

    Dir -ADir -BRep

    DXC

    Dir -ADir -BRep

    DXC

    Dir -A

    D/I for A

    DXC

    Dir -A

    D/I for A

    DXC

    TERMINAL

    REPEATER

    TERMINAL REPEATER

    User Interface PDH E1 with LAN PDH E1 with LAN

    Redundancysetting

    (1+0) (Term) 2-way PDH

    INTFC Main 16E1 2-Way/XC PKG(E/W LAN) 16E1 2-Way/XC PKG(E/W LAN)

    Modulation QPSK 16 QAM QPSK QPSK 16QAM 16QAM

    10 10 10 10 10 10

    80 80 80

    TRANSMISSION

    CAPACITY

    20 20 20 20 20 20

    40 40 40 40 40 40

    DIR-A DIR-B DIR-A DIR-B

    1. Select PDH E1 with LAN as User Interface

    2. For Redundancy Setting

    Select (1+0) TERM for Terminal Configuration

    Select (2-WAY PDH for Repeater Configuration

    3. Interface Main: 16E1 2-Way/XC PKG (E/W LAN)

    4. Interface Main: 16E1 2-Way/XC PKG (E/W LAN)

    5. Select the Modulation scheme. For repeater select

    for DIR-A & DIR-B

    6. Select the Transmission Capacity. For repeaterselect for DIR-A & DIR-B (Depends on the selected

    Modulation scheme

    PROVISIONINGPROVISIONING XC SETTING (TERMINAL)XC SETTING (TERMINAL)

  • 5/26/2018 Copy of Paso Neo Presentation

    22/49

    22222007NOV152007NOV15NEC ConfidentialNEC Confidential

    PROVISIONINGPROVISIONING XC SETTING (TERMINAL)XC SETTING (TERMINAL)

    Dir -A

    Tributary LB

    DXC

    Dir -A

    DXC

    D/I for A

    Select XC Function Enabled to Map the DIR-A and Tributary

    Channels as required.

    To set all DIR-A channels to

    Tributary, one-to-one click

    this button

    Click and select DIR-A to assign

    the radio channels to Tributary

    Channels

    Click and select Tributary to

    assign the Tributary channels to

    radio Channels

    Click and select for each radio

    channel the mapping Tributary or

    space (No Assignment)

    Click and select the Tributary

    Channel number to be assigned

    to the radio channel

    Click the CH MAP

    button to see theconnection graphically

    Mapping displayMapping display

  • 5/26/2018 Copy of Paso Neo Presentation

    23/49

    23232007NOV152007NOV15NEC ConfidentialNEC Confidential

    Mapping displayMapping display

    Assign the channel mapping.

    Indicate the mapping

    CH MAP : Graphical display of thechannel mapping

    LAN ASSIGNMENT NOT SHOWN HERE

    Indicate the mapping for each type of channel

    Dir-A, DIR-B and Tributary

    PROVISIONINGPROVISIONING XC SETTING (REPEATER)XC SETTING (REPEATER)

  • 5/26/2018 Copy of Paso Neo Presentation

    24/49

    24242007NOV152007NOV15NEC ConfidentialNEC Confidential

    PROVISIONINGPROVISIONING XC SETTING (REPEATER)XC SETTING (REPEATER)

    Show the connection between the radio channels and

    the tributary channels

    Dir -ADir -BRep

    DXC

    Dir -ADir -BRep

    DXC

    Click this button to set all DIR-A channels to Tributary

    Channels

    Click this button to set all DIR-A channels to DIR-B

    Channels (No drop & Insert)

    22 Way Expandable Type (4x2Way Expandable Type (4x2 Way)Way)

  • 5/26/2018 Copy of Paso Neo Presentation

    25/49

    25252007NOV152007NOV15NEC ConfidentialNEC Confidential

    22--Way Expandable Type (4x2Way Expandable Type (4x2--Way)Way)

    Digital Cross Connect function Max. 8-Way Configuration using 4 IDUs

    Max. 48E1 (100Mbps) Air Capacity

    Air Compatibility with STD PDH menu STM-1 Termination

    FAN Unit is necessary

    FAN UNIT

    Structure ofStructure of 6 Way Box6 Way Box Nodal Radio EquipmentNodal Radio Equipment

  • 5/26/2018 Copy of Paso Neo Presentation

    26/49

    26262007NOV152007NOV15NEC ConfidentialNEC Confidential

    yy q pq p

    AP (Interface Card)

    MODEM

    CS(DXC)

    OAM&P

    RA (Radio Access Card)

    AUX

    P_INF (Power Supply Card)

    F

    A

    N

    AUX : Auxiliary interface Card

    OAM&P : Operation, Administration,

    Maintenance and Provisioning

    Interface Card lineInterface Card line--upup

  • 5/26/2018 Copy of Paso Neo Presentation

    27/49

    27272007NOV152007NOV15NEC ConfidentialNEC Confidential

    Interface Card lineInterface Card line upup

    Interface Card line-up is as follows.Card Function

    32xE1 Interface 32x E1, (2x MDR 68pin)

    STM-4 (OPT) Interface 1x STM-4 (SFP)

    PDH Fast Ethernet Interface 6x FE (for PDH Radio)

    SDH Fast Ethernet Interface 6x FE (for SDH Radio)

    SDH Giga-bit Ethernet Interface 2x GbE (for SDH Radio)

    STM-1 (OPT/ELE) Interface 4x STM-1 (SFP)

    Combination of Interface CardCombination of Interface Card

  • 5/26/2018 Copy of Paso Neo Presentation

    28/49

    28282007NOV152007NOV15NEC ConfidentialNEC Confidential

    Combination of Interface CardCombination of Interface Card

    Different interface cards are mountable in a same box.

    Interface Card

    (32E1 INTFC)

    (FE INTFC)

    (STM-1 ELE)

    (STM-1 OPT)

    FAIL

    PWR

    1000BASEPORT1

    ACT2ACT1

    LINK2LINK1

    PORT1P ORT4 P ORT3 P ORT2OUT IN

    1000BASEPORT2

    OUT IN

    FAIL

    PWR

    PORT1PORT6 PORT5 PORT4 PORT3 PORT2

    FAIL

    PWR

    ONLINEOUT IN

    STM-1CH4

    1

    4 2

    3

    OUT IN

    STM-1CH3

    OUT IN

    STM-1/4CH2

    OUT IN

    STM-1/4 CH1

    FAIL

    PWR

    2M IN/ OUT-A 2M IN/OUT-B

    FAIL

    PWR

    ONLINEOUT IN

    STM-1CH4

    1

    4 2

    3

    OUT IN

    STM-1CH3

    OUT IN

    STM-1/4 CH2

    OUT IN

    STM-1/4CH1

    (GbE INTFC) (STM-4)

    FAIL

    PWR

    ONLINEOUT IN

    STM-1CH4

    1

    4 2

    3

    OUT IN

    STM-1CH3

    OUT IN

    STM-1/4CH2

    OUT IN

    STM-1/4 CH1

    Five interface card slots

    Upgradeable

    Scalable

    Low initial cost

    Network Application (1)Network Application (1)

  • 5/26/2018 Copy of Paso Neo Presentation

    29/49

    29292007NOV152007NOV15NEC ConfidentialNEC Confidential

    4x STM-1

    NxE1 NxE1

    NxE1

    NxE1

    NxE1

    NxE1NxE1NxE1

    XPIC

    4x STM-1

    NEO Nodal

    N-way solution for high density site

    NEO Standard

    NxE1

    NxE1

    NxE1

    NxE1

    NxE1

    NxE1

    NxE1

    NxE1

    BSC

    NEO Standard

    Network Application (1)Network Application (1)

    - NEO Nodal and NEO Standard can be connected by air.- Different frequencies, capacities, and modulation types are supported in the same box.

    Network Application (2)Network Application (2)

  • 5/26/2018 Copy of Paso Neo Presentation

    30/49

    30302007NOV152007NOV15NEC ConfidentialNEC Confidential

    STM-4

    NxE1

    NxE1

    NxE1

    NxE1

    STM-1STM-1

    NEO Nodal

    N-Way solution for high capacity site

    NEO Standard

    NxE1

    STM-1

    NxE1

    NxE1

    NxE1

    STM-1

    STM-4

    (optical cable)

    BSC

    Network Application (2)Network Application (2)

    NEO Standard

    - Planned Support for STM-4 Interface.

    - Connection to the core network (BSC, etc.) by Radio, Optical or Ethernet.

    Nodal Radio Road Map MenuNodal Radio Road Map Menu

  • 5/26/2018 Copy of Paso Neo Presentation

    31/49

    31312007NOV152007NOV15NEC ConfidentialNEC Confidential

    Nodal Radio Road Map Menup

    Currently AvailableCurrently Available

    2 Way Fixed Type2 Way Fixed Type

    2 Way Expandable Type (8 Way)2 Way Expandable Type (8 Way)

    ReleaseRelease--11 1Q 20081Q 2008

    6-Way Radio

    Baseband Interface : STM-1 (OPT/ELE), 32E1

    Air Capacity : STM-1, 5-48E1 (Bitrate free)DXC Function (Capacity : 1008x1008E1)

    1+0, 1+1 Hot Standby

    ReleaseRelease

    --22

    Under schedulingUnder scheduling

    Baseband Interface : FE(SDH), FE(PDH)

    CS & RA Module Redundancy

    AUX Interface

    1+1 Twin Path

  • 5/26/2018 Copy of Paso Neo Presentation

    32/49

    32322007NOV152007NOV15NEC ConfidentialNEC Confidential

    PASOLINK NEOPASOLINK NEO

    LANLAN (Ethernet)(Ethernet) FunctionFunction SummarySummary

    LANLAN (Ethernet)(Ethernet) FunctionFunction SummarySummary

  • 5/26/2018 Copy of Paso Neo Presentation

    33/49

    33332007NOV152007NOV15NEC ConfidentialNEC Confidential

    Interface Card 16E1+2LAN INTFC 4LAN +8E1 INTFC E3+2LAN INTFCLAN/WSINTFC

    2Way DXC (16E1+2LAN)

    System PDH(10~80MB) PDH(80MB) PDH(40~80MB) SDH(156MB) PDH(10~80MB)

    10Base-T

    100Base-TX

    2 (RJ-45)

    ~80Mbps

    N.A

    ~256Kbps

    1548 bytes

    1024, 5min

    512Kbit

    RMON Supported Supported Supported Supported Supported Supported

    SDH(156MB)

    Address Table / Aging 1024, 5min 1024, 5min 1024, 5min 1024, 5min N.A

    Frame Buffer 512Kbit 512Kbit 512Kbit 512Kbit 336Kbit

    10Base-T

    100Base-TX

    2 (RJ-45)

    Main N.A

    WS N.A N.A ~16Mbps 2Mbps N.A

    SC ~256Kbps N.A ~256Kbps ~256Kbps N.A

    1548 bytes

    GbEINTFC

    Interface10Base-T

    100Base-TX

    10Base-T

    100Base-TX

    10Base-T

    100Base-TX

    1000Base-T

    1000Base-SX

    1000Base-LX

    1 (SFP/RJ-45)

    150Mbps

    9600 bytes

    Number of LAN Port 2 (RJ-45) 4 (RJ-45) 2 (RJ-45)

    ~80Mbps ~100Mbps 150Mbps

    Maximum Frame Length 1548 bytes 1548 bytes 1548 bytes

    MaximumThroughput

    *

    *2*2 *2*2 *2

    N.A: Not Available*1 1000BASE-LX/SX and 1000BASE-T are exclusive use. (It is not possible to use at the same time.)

    *2 When VLAN is enabled, maximum frame length is limited to 1522 bytes.

    When VLAN is disabled, ISL transparency transmitting is supported.

    Transmission modeTransmission mode (PDH)(PDH)

  • 5/26/2018 Copy of Paso Neo Presentation

    34/49

    34342007NOV152007NOV15NEC ConfidentialNEC Confidential

    1. Separated mode

    Each Port is completely

    independent.

    2. Shared mode

    All Port are transmitted by

    using the same band.

    3. Shared mode + Switching Function

    PORT 1

    PORT 2

    PORT 1

    PORT 2

    A A

    B

    A B

    B

    BA

    B

    A

    ST -1 ST -2

    Signals can pass between

    local ports too.

    Transmission modeTransmission mode (SDH)(SDH)

  • 5/26/2018 Copy of Paso Neo Presentation

    35/49

    35352007NOV152007NOV15NEC ConfidentialNEC Confidential

    1. 2Port LAN

    A : B

    a. 75M : 75M

    b. 100M : 50M

    c. 100M : disable

    d. Best Effort

    PORT1

    PORT2

    PORT1

    PORT2

    A A

    B

    A

    B

    ST- 1 ST- 2

    150Mbps B

    Each Port is completely

    independent.

    2. GbE LAN

    GbE INTFC supports only

    one port.

    Application exampleApplication example (4port LAN)(4port LAN)

  • 5/26/2018 Copy of Paso Neo Presentation

    36/49

    36362007NOV152007NOV15NEC ConfidentialNEC Confidential

    pp ppp p ( p )( p )

    Guaranteed bandwidth service

    (P1-4 Separated mode)

    4 ports are completely separated and guaranteed

    maximum throughput for each port.

    Data distribution service 1: 4 asymmetrical network, like as connecting datacenter and terminals.(P1-4 Shared mode)

    Adaptive Modulation Radio

  • 5/26/2018 Copy of Paso Neo Presentation

    37/49

    37372007NOV152007NOV15NEC ConfidentialNEC Confidential

    Two types of AMR (Hit type and Hitless type) are under development.

    Even hit type, the interruption time is small (

  • 5/26/2018 Copy of Paso Neo Presentation

    38/49

    38382007NOV152007NOV15NEC ConfidentialNEC Confidential

    28MHz

    QPSK

    20E1

    (40Mbps)

    Normal conditionCritical condition

    28MHz

    32QAM

    48E1

    (100Mbps)

    28MHz

    16QAM

    40E1

    (80Mbps)

    or

    Modulation scheme and Traffic capacity are automatically selected in accordance with the pathcondition.

    or LAN

    or LAN

    Example

    IDU Standard

    Additional capacity in clear sky conditionby using high density modulation(16QAM/32QAM) in the same channel bandwidth.

    Dynamic Modulation Radio

  • 5/26/2018 Copy of Paso Neo Presentation

    39/49

    39392007NOV152007NOV15NEC ConfidentialNEC Confidential

    Dynamic Modulation Radio (DMR)

    There is interruption when switching

    Interruption time : 400msec (NECs specification)

    300msec (typical value)

    - Dynamic Modulation Radio with 48E1 Interface

    Supported Modulation Schemes

  • 5/26/2018 Copy of Paso Neo Presentation

    40/49

    40402007NOV152007NOV15NEC ConfidentialNEC Confidential

    Sunny conditionRainy condition

    bandwidth

    Menu 1: 7MHz

    10E1 / 16QAM5E1 / QPSK

    Menu 2: 14MHz

    20E1 / 16QAM10E1 / QPSK

    Menu 3: 28MHz

    40E1 / 16QAM20E1 / QPSK

    Menu 4: 28MHz

    48E1 / 32QAM20E1 / QPSK

    SwitchSwitch--over process Exampleover process Example

  • 5/26/2018 Copy of Paso Neo Presentation

    41/49

    41412007NOV152007NOV15NEC ConfidentialNEC Confidential

    (48E1/32QAM(48E1/32QAM 20E1/QPSK20E1/QPSK, 28MHz band, 28MHz band))

    Switch from

    32QAM to QPSK

    Switch from

    QPSK to 32QAM

    32QAM QPSK 32QAM

    -73dBm

    (48E1/32Q

    BER=10-9)

    -65dBm

    -85dBm

    (20E1/QPSK

    BER=10-3)

    RSL

    -76.5dBm

    (48E1/32Q

    BER=10-3)

    Tx power difference(5 dB)

    Outage Area(48E1/32QAM)

    -70dBm

    -60dBm

    48E1 20E1 48E1

    Operation threshold

    Outage Area(20E1/QPSK)

    Recovery threshold

  • 5/26/2018 Copy of Paso Neo Presentation

    42/49

    42422007NOV152007NOV15NEC ConfidentialNEC Confidential

    Development item

    to be made in/after 2008

    Traffic ShapingVLAN CARD

  • 5/26/2018 Copy of Paso Neo Presentation

    43/49

    43432007NOV152007NOV15NEC ConfidentialNEC Confidential

    QoS Support (802.1p COS)

    Data with h igh priority is transmitted

    IDU

    GbEe.g. STM-1/155Mbps

    Queuing

    Switch/Router

    VL2VL3VL1VL1

    VL2

    VL3

    VLAN with high priority is s tored in

    high priority queue buffer.

    VL1VL1

    .

    .

    VLAN

    tagging

    Vo IP

    Data-P2

    Data-P1

    IDU

    VL1

    VL2

    VL3Priority

    high

    Low VL4

    VLAN

    tagging

    Vo IP

    Data-P2

    Data-P1

    * COS : Class of Service* TOS : Type of Service

    Tag-based VLANVLAN CARD

  • 5/26/2018 Copy of Paso Neo Presentation

    44/49

    44442007NOV152007NOV15NEC ConfidentialNEC Confidential

    - Tag-based VLAN (802.1Q VLAN)The connection between each clients can be set-up by using VLAN ID.

    Connection Example

    High Capacity RadioNEO Enhanced

  • 5/26/2018 Copy of Paso Neo Presentation

    45/49

    45452007NOV152007NOV15NEC ConfidentialNEC Confidential

    IDUXPIC ODU

    STM-2/128QAM

    (310MB)

    ODUIDUXPIC

    28MHz

    STM-1

    56MHz

    STM-2310MB

    56MHz28MHz

    STM-1

    STM-1

    V

    H

    STM-2310MBSTM-2

    310MB

    STM-1 2xSTM-1/XPIC STM-2 / Carrier 2xSTM-2 / XPIC

    STM-2/128QAM

    (310MB)

    IDU ODUSTM-1

    STM-1

    STM-1

    STM-1

    STM-1

    STM-1

    One Box (IDU)

    STM-2/128QAM(310MB)

    NEO Enhanced

  • 5/26/2018 Copy of Paso Neo Presentation

    46/49

    46462007NOV152007NOV15NEC ConfidentialNEC Confidential

    IDUXPIC

    STM-1ODU

    STM-2/128QAM(310MB)

    ODU

    IDUXPICSTM-1 ODU

    STM-1/128QAM

    XPIC

    IDU ODUSTM-1

    V

    H

    IDUXPIC

    STM-1

    STM-1

    STM-1

    IDU

    replacementonly

    IDU

    replacement

    only

    Same ODU

    for V and H

    Same ODU

    for V and H

    STM-1/128QAM

    STM-2/128QAM(310MB)

    2xSTM-1/XPIC 2xSTM-1/Carrier/XPIC

    One Box (IDU)

    V

    H

    High Capacity RadioNEO Enhanced

  • 5/26/2018 Copy of Paso Neo Presentation

    47/49

    47472007NOV152007NOV15NEC ConfidentialNEC Confidential

    IDUXPIC ODU

    STM-2/128QAM

    (310MB)

    ODUIDUXPIC

    56MHz

    STM-2310MB

    56MHz

    STM-2310MBSTM-2

    310MB

    STM-2 / Carrier

    STM-2/128QAM

    (310MB)

    IDU ODU

    2xSTM-2 /XPIC

    GbE

    GbE

    GbE

    GbE over STM-4One Box (IDU)

    V

    H

    STM-2/128QAM

    (310MB)

    High Capacity RadioNEO Enhanced

  • 5/26/2018 Copy of Paso Neo Presentation

    48/49

    48482007NOV152007NOV15NEC ConfidentialNEC Confidential

    IDUXPIC ODU

    STM-2/128QAM(310MB)

    ODUIDUXPIC

    56MHz

    STM-2310MBSTM-2

    310MB

    2xSTM-2 / XPIC / STM-4 Interface

    STM-4

    One Box (IDU)

    V

    H

    STM-2/128QAM(310MB)

    Available 2007

    Products Road Map

    2008

  • 5/26/2018 Copy of Paso Neo Presentation

    49/49

    49492007NOV152007NOV15NEC ConfidentialNEC Confidential

    Available 2007 2008 2009

    High Capacity

    IP Transport

    Nodal Radio

    Dynamic

    Modulation

    Radio

    16E1+2LAN(80MB)

    48E1, 4por t LAN1E3/2E3

    STM-1(opt/elec), STM-1(2LAN)

    WS/LAN, APS, XPIC

    GbE

    16E1+2LAN DXC (2Way Repeater)

    Standard

    Functionality

    2xSTM-1/XPIC

    80/96E1

    /XPIC 2xSTM-2

    /XPIC

    2Way Repeater

    FE, GbE

    VLAN/QoS

    (4FE, 3FE+GbE)

    32E1+2LAN

    (100MB)

    2/3/4x2Way 4xSTM-1

    /XPIC

    STM-4 Interface

    GbE(620MB)6Way/2x6Way

    48E1/DXC

    63E1PDH SNCP

    Dynamic

    Modulation

    (hit-type