1
Production Status: Service Replacement Model CFC, R-12, Mid Point, 60 Hz, 3 - Phase, 208/230 V KATA-015E-TAC Power (Watts): Current (Amps): EER (Btu/Wh): Mass Flow (lbs/hr): 230.0 7.1 6.2 1630 1280 4.9 6.0 144.0 Overall Length (in): Overall Width (in): Overall Height (in): 9.5 10.44 8.19 6.38 Mounting Height (in): 11.19* Mounting Width(in): Mounting Length (in): 14.38 1.156 Stroke (in): 7640 11500 Capacity (Btu/hr): Bore Size (in): 1.875 Displ (ft^3/hr): 387.8944 6.384 Displ (in^3/Rev): 2 Number of Cylinders: 65 / 110 65 / 120 Mechanical Performance Sound Power(dBA): Vibration (mils(peak-peak)): 0 Ave 0 Max 0.0 Ave 0.0 Max 22 20 Oil Recharge (oz): Initial Oil Charge (oz): Discharge Size (in): Suction Size (in): 93.0 Net Weight (lbs): 7.0 MCC (Amps): RPM: CSA File No.: 35.5 LRA-Half Winding: LRA-High*: LRA-Low*: UL File Date: 23-Jul-1984 UL File No.: Electrical Max Operating Current: 0 / 110 20 / 120 1/2 Flare 7/8 Sweat Medium Temperature Evap F )/ Cond F ) RG F )/ Liq F ) Internal Free Volume (in^3): * HorsePower *Low and High refer to the low and high nominal voltage ranges for which the motor is approved. Overall compressor height on Copeland Brand Product's specified mounting grommets. RLA(=MCC/1.4; use for contactor selection): 5 RLA (=MCC/1.56; use for breaker & wire size selection): 4.5 2007-02-09 Record Date: Alternate Applications Application Voltage Phase Refrigerant Frequency(Hz) 200/220 3 R-12 CFC 50 Medium Temperature 200/220 3 R-134a HFC 50 200/220 3 R-404A HFC 50 200/220 3 R-404A HFC 50 200/220 3 R-507 HFC 50 200/220 3 R-507 HFC 50 208/230 3 R-134a HFC 60 208/230 3 R-404A HFC 60 208/230 3 R-404A HFC 60 Extra-Low Temperature 208/230 3 R-507 HFC 60 208/230 3 R-507 HFC 60 Extra-Low Temperature Charles, Bartlett. Page 1 of 1 6/22/2009 Copyright © 2008 Emerson Climate Technologies, Inc. All rights reserved.

Upload: payo55

Post on 21-Apr-2015

93 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Copeland Kata 015e Tac

Production Status: Service Replacement Model

CFC, R-12, Mid Point, 60 Hz, 3 - Phase, 208/230 V

KATA-015E-TAC

Power (Watts):Current (Amps):EER (Btu/Wh):Mass Flow (lbs/hr): 230.0

7.16.21630 1280

4.96.0144.0

Overall Length (in):Overall Width (in):Overall Height (in):

9.510.44

8.196.38

Mounting Height (in): 11.19*Mounting Width(in):Mounting Length (in):14.38

1.156Stroke (in):764011500Capacity (Btu/hr):

Bore Size (in): 1.875 Displ (ft^3/hr): 387.89446.384Displ (in^3/Rev):2Number of Cylinders:

65/11065/120

MechanicalPerformance

Sound Power(dBA):Vibration (mils(peak-peak)):

0 Ave 0 Max0.0 Ave 0.0 Max 22

20Oil Recharge (oz):Initial Oil Charge (oz):Discharge Size (in):Suction Size (in):

93.0Net Weight (lbs):

7.0 MCC (Amps):

RPM: CSA File No.:

35.5 LRA-Half Winding:

LRA-High*:

LRA-Low*: UL File Date: 23-Jul-1984

UL File No.:

Electrical

Max Operating Current:

0/11020/120

1/2 Flare 7/8 Sweat

Medium Temperature

Evap(°F)/Cond(°F)RG(°F)/Liq(°F)

Internal Free Volume (in^3):

*HorsePower

*Low and High refer to the low and high nominal voltage ranges for which the motor is approved.

Overall compressor height on Copeland Brand Product's specified mounting grommets.

RLA(=MCC/1.4; use for contactor selection): 5RLA (=MCC/1.56; use for breaker & wire size selection): 4.5

2007-02-09Record Date:

Alternate Applications

ApplicationVoltagePhaseRefrigerant Frequency(Hz)

200/2203R-12 CFC 50 Medium Temperature200/2203R-134a HFC 50200/2203R-404A HFC 50200/2203R-404A HFC 50200/2203R-507 HFC 50200/2203R-507 HFC 50208/2303R-134a HFC 60208/2303R-404A HFC 60208/2303R-404A HFC 60 Extra-Low Temperature208/2303R-507 HFC 60208/2303R-507 HFC 60 Extra-Low Temperature