cooling tower improvement study using pepse - …famos.scientech.us/pdfs/2013 epri...
TRANSCRIPT
![Page 1: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/1.jpg)
Cooling Tower Improvement Study Using PEPSE
EPRI Heat Rate Improvement ConferenceFebruary 5-7, 2013
Justin StruppScientech, a business unit of Curtiss-Wright Flow Control
Scott ProkopetzSaskPower
![Page 2: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/2.jpg)
Shand Power Station
Single-Unit Lignite Coal PlantEstevan, Saskatchewan, CanadaCommissioned in 1992 305 MW GrossB&W BoilerHitachi Steam Turbine
![Page 3: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/3.jpg)
Cooling System
![Page 4: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/4.jpg)
Main Cooling Towers
OEM – Ceramic Cooling Tower, installed in 1992 Induced Draft, Counterflow, Clay Tile Fill
![Page 5: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/5.jpg)
Auxiliary Cooling Towers
OEM – Psychrometric Systems Inc, installed 2000 Induced Draft, Counterflow, PVC Fill
![Page 6: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/6.jpg)
Problem
Since construction, Shand Power Station has had historically higher than design condenser backpressure Auxiliary towers were added in 2000 but the
problem remainedCauses
– Cooling Water (CW) flow slightly lower than design 92 – 95% design flow to condenser
– Cooling Towers performing lower than design 70 – 80% capability
– Condenser cleanliness slightly lower than design average 80% (design 90%)
![Page 7: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/7.jpg)
Effects of Problem
Forced Plant De-rates– In the summer, back pressure increases to a point near
the maximum allowable for the turbine– MW output must be lowered to stay within the back
pressure limits of the turbine– De-rates cost $800,000 per year in replacement energy
costs
Increased Heat Rate– As back pressure increases, the boiler must fire harder– Heat rate effect has not been quantified
![Page 8: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/8.jpg)
Possible Improvement Areas
Increase cooling water flow Increase air flow to the main cooling towersAdditional cooling tower cellsUpgrade water distribution system in main towersUpgrade fill in main towers
First three can be modeled with PEPSE
![Page 9: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/9.jpg)
Modeling of Possible Improvement Areas
CW Flow– 15% under design flow– 30% over design flow
Main Cooling Tower Air Flow– 15% under design flow– 25% over design flow
Adding cooling tower cells– One cell to auxiliary cooling tower– Two cells to auxiliary cooling tower– One cell to main cooling tower– Two cells to main cooling tower
![Page 10: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/10.jpg)
Turbine Cycle Modeling
Turbine Cycle– Heat Balance Tuned– Plant Data– Design mode Condenser
![Page 11: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/11.jpg)
Cooling Tower Modeling
Cooling Towers – Main and AuxiliaryCooling Tower Performance CurvesCooling Tower Tuning
![Page 12: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/12.jpg)
Merged Model
![Page 13: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/13.jpg)
Turbine Cycle Assumptions
MCR Main Steam and Reheat Conditions Feedwater Heater TTD and DCA ConstantOther ConditionsDesign Condenser Cleanliness FactorDe-rate Conditions
– LP Turbine Exhaust above 50°C– Main steam flow reduced
![Page 14: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/14.jpg)
Cooling Tower Assumptions
Five wet-bulb temperatures – 24°C, 23°C, 21°C, 18°C, and 17°C– 50% Humidity– 94.5 kPa Pressure
Cooling Tower ConditionsCCCW System
![Page 15: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/15.jpg)
CW Flow Calculations
Change the CW flow from 85% to 130% of design CW Flow
![Page 16: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/16.jpg)
CW Flow Results - MW
265
270
275
280
285
290
295
300
85 90 95 100 105 110 115 120 125 130
Gro
ss O
utpu
t (M
W)
CW Flow (%)
Gross MW Output for CW Flow Change
24°C21°C17°C
![Page 17: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/17.jpg)
CW Flow Results - HR
1019010200102101022010230102401025010260102701028010290
85 90 95 100 105 110 115 120 125 130
GU
HR
(kJ/
kWh)
CW Flow (%)
Gross Unit HR for CW Flow Change
24°C21°C17°C
![Page 18: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/18.jpg)
Fan Air Flow Calculations
Main Cooling Tower Only Fan Affinity Law
100150200250300350400450500
1.5E+07
1.7E+07
1.9E+07
2.1E+07
2.3E+07
2.5E+07
85 95 105 115 125
Fan
Pow
er (k
W)
Air
Flow
Rat
e (k
g/hr
)
Air Flow of Design (%)
Fan Air Flow Rate and Power
Air Flow Rate (kg/hr) Fan Power (kW)
![Page 19: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/19.jpg)
Fan Air Flow Results - MW
265
270
275
280
285
290
295
300
85 90 95 100 105 110 115 120 125
Gro
ss O
utpu
t (M
W)
Air Flow (%)
Gross MW Output for Air Flow Change
24°C21°C17°C
![Page 20: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/20.jpg)
Fan Air Flow Results - HR
1019010200102101022010230102401025010260102701028010290
85 90 95 100 105 110 115 120 125
GU
HR
(kJ/
kWh)
Air Flow (%)
Gross Unit HR for Air Flow Change
24°C21°C17°C
![Page 21: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/21.jpg)
Additional Cells Calculations
Flow Split to each cooling towerNumber of CellsSource Air FlowCTI CW Flows
![Page 22: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/22.jpg)
Adding Cooling Tower Cells Results - MW
280
282
284
286
288
290
292
294
296
Base 1 Aux. 2 Aux. 1 Main 2 Main
Gro
ss O
utpu
t (M
W)
Gross MW Output for Adding Cells
24°C21°C17°C
![Page 23: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/23.jpg)
Adding Cooling Tower Cells Results - HR
10170
10190
10210
10230
10250
10270
10290
Base 1 Aux. 2 Aux. 1 Main 2 Main
GU
HR
(kJ/
klW
h)
Gross Unit HR for Adding Cells
24°C21°C17°C
![Page 24: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/24.jpg)
The use of the PEPSE Data
Review which options were worth exploring further:– Feasibility of implementation– Cost of implementation– Effects on other parts of the system
Provide benefits found to the second part of the study:– Potential benefits– Cost justification
![Page 25: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/25.jpg)
Conclusion
Study to choose best improvement option(s) is still ongoingSo far, indications are that a distribution system /
fill upgrade in the main towers will offer the greatest improvementStudy will provide which option or combination of
options is best suited to improve the back pressure issue
![Page 26: Cooling Tower Improvement Study Using PEPSE - …famos.scientech.us/PDFs/2013 EPRI Papers/Cooling_Tower_Improveme… · Cooling Tower Improvement Study Using PEPSE ... Single-Unit](https://reader031.vdocuments.mx/reader031/viewer/2022021818/5aae422d7f8b9aa8438bd050/html5/thumbnails/26.jpg)
Questions?