conventional heat tracing (1)inko.com.sg/image/data/catalog/csi/csi-9.pdf · 2018-09-19 ·...
TRANSCRIPT
![Page 1: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/1.jpg)
Conventional heat tracing (1)
• The best heat
transfer ever !
• But it is
EXPENSIVE !
• And difficult to
maintain !
![Page 2: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/2.jpg)
ST
EA
M D
IS
TR
IB
UT
IO
N
MA
NIF
OL
D
CO
ND
EN
SA
TE
C
OL
LE
CT
IO
N
MA
NIF
OL
D
Steam heat tracing tube
Conventional heat tracing (2)
![Page 3: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/3.jpg)
Conventional heat tracing (2)
• Product flow in the main pipeline
• Steam filled tracing tube is at the
outside of the main pipe (could be
more than one tube depend the
size of the main pipe)
• To prevent burning of the product
inside of the main pipe Tracer tube
with a thin insulation !
![Page 4: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/4.jpg)
CSI (ControTrace®) heat tracing
![Page 5: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/5.jpg)
CSI (ControTrace®) heat tracing
Conventional steam
tracing tube ControTrace® steam
tracing
![Page 6: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/6.jpg)
CSI (ControTrace®) heat tracing
![Page 7: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/7.jpg)
ControTrace® for piping
![Page 8: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/8.jpg)
ControTrace® heat tracing is called also bolt-on
type of heat tracing Because it is using clamp to
tie it to the pipe or vessel.
CLAMP CLAMP
ControTrace® for piping
BOLT
![Page 9: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/9.jpg)
ControTrace® for tank/vessel
![Page 10: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/10.jpg)
ControTrace® for tank/vessel
![Page 11: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/11.jpg)
ControHeat® jacket
CSI makes ControHeat Bolt-On
Jackets for virtually any valve.
Generally, there are two types of
jacket construction offered:
• One-piece jackets, called
Uni-Jacket, for valves sizes
3-inch and smaller; and
• Two-piece jackets for valves
sizes 4-inch and larger.
• Very large valves like 20-inch
gate valves may utilize more
than two-pieces to
accommodate ease of
installation
![Page 12: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/12.jpg)
ControHeat® jacket
How The ControHeat Jacket Works:
1. Pressurized heating fluid enters the
pressure chamber embedded in the
aluminium casting. The pressure
chamber may be either carbon steel or
stainless steel.
2. The pressure chamber is designed,
manufactured and tested in accordance
with the ASME Boiler and Pressure
Vessel Code, Sec. VIII, Div.1.
3. The aluminium casting, which never
contacts the pressurized heating fluid,
rapidly transfers heat from the pressure
chamber to the external surface of the
valve.
4. Normally, heat transfer cement is used
with the jacket to minimize any air gap
between the casting and the valve
body. The cement promotes efficient
heat transfer
![Page 13: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/13.jpg)
ControHeat® jacket
![Page 14: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/14.jpg)
ControHeat® jacket
![Page 15: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/15.jpg)
ControHeat® jacket
![Page 16: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/16.jpg)
ControHeat® jacket
![Page 17: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/17.jpg)
ControHeat® jacket
![Page 18: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/18.jpg)
ControHeat® jacket
![Page 19: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/19.jpg)
No Cross-Contamination.
• In conventional heat tracing Effects in castings
or cracks in core piping can cause cross-
contamination.
• The double-wall design of the bolt-on heating
system eliminates the possibility of cross-
contamination.
• The heating fluid can’t reach the process, and the
process can’t flood the heating system.
ControHeat® & ControTrace® benefit
![Page 20: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/20.jpg)
Economical Temperature Control.
• Depending on the thermal requirements of the
process, the CSI Bolt-On Heating System can
offer significant cost savings compared to a fully
jacketed processing system.
• In general, the cost of the clamp-on system
increases as the required temperature of the
process approaches the temperature of the
heating fluid.
• When the design temperature envelope is very
narrow, say 2-4°F, designers must carefully
analyse potential chill spots to determine the
optimum heat coverage.
ControHeat® & ControTrace® benefit
![Page 21: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/21.jpg)
Component Selection Versatility.
• Because components of the system most often
are line-size components, project engineers can
select from a very broad range of standard
products.
• The base component, of course, must be able to
operate at elevated design temperatures.
• More than 3500 typical processing components
are represented in the ControHeat Jacket
pattern inventory.
• Several new patterns are added to this inventory
each week
ControHeat® & ControTrace® benefit
![Page 22: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/22.jpg)
Low Maintenance Costs.
• Practically any piece of equipment or process
component can be economically heated with a
bolt-on jacket.
• Because standard line-size components can be
used throughout the system, the replacement of
individual components like a valve can be made
without concerns for long lead times and “crises”
expediting.
ControHeat® & ControTrace® benefit
![Page 23: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/23.jpg)
Jump-over hose
To connect one section of bolt-on of ControTrace® heat tracer
with the other ControTrace® heating tracer OR
To connect one section of bolt-on of ControTrace® heat tracer
with the ControHeat® heat jacket
It needs a Jump-over hose
![Page 24: Conventional heat tracing (1)inko.com.sg/image/data/CATALOG/CSI/CSI-9.pdf · 2018-09-19 · Conventional heat tracing (2) • Product flow in the main pipeline • Steam filled tracing](https://reader033.vdocuments.mx/reader033/viewer/2022042013/5e7310d8a379675e8c6c1cbd/html5/thumbnails/24.jpg)
Jump-over hose & Steam trap
For steam tracing system
There will be a steam trap at the end of the line to drain the
condensate out of the heat tracing system.