consumer switchboards and circuit protection - nhp · pdf filepower distribution and...

28
POWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial NHP Electrical Engineering Products Pty Ltd 1300 NHP NHP 0800 NHP NHP nhp.com.au nhp-nz.com NZ AUS

Upload: hanhan

Post on 06-Mar-2018

268 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

POWER DISTRIBUTION AND PROTECTION

Consumer Switchboards and Circuit ProtectionFlexible range designed for domestic and commercial

NHP Electrical Engineering Products Pty Ltd1300 NHP NHP0800 NHP NHP

nhp.com.aunhp-nz.comNZ

AUS

Page 2: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

SURGE DIVERTERS• Standard IEC 61643-1 (Class 2)

• Status indication (via flag)

• DIN rail mounting

• Thermal disconnection

DIN RAIL MOUNTING

VOLT FREE CONTACT FOR REMOTE INDICATION

I, 2, 4 POLE

NHP MOD6 is a flexible range of products to cater for the ever changing demands of switchboard design.

MCBs

• Standard AS / NZS 60898

• DIN rail mounting

• Suits both loadcentres and panelboards

• General light and power applications

6 - 63 A

6 kA

1, 2, 3 POLE

PANELBOARDS• Standard AS / NZS 3439.3

• Compact 160 A or 250 A main switch

• 24, 36, 48, 60 and 84 way

• 400 mm high accessory module

NEW WIDTH NOW 530 mm

HINGED ESCUTCHEON

ACCESSORY MODULE

ENCLOSURES (SWITCHBOARDS)• Surface mount or flush mount

• Transparent door or white door

• Metal backing plate option - mechanical protection

• Neutral bars suit either RCCB or RCBO

SURFACE OR FLUSH MOUNT

12 - 36 WAY

PRELOADED MODELS

RCDs and MAIN SWITCHES• Standard AS / NZS 61008 RCCBs, AS / NZS 61009 RCBOs

• Compact RCBO - same size as MCB

• 30 mA sensitivity

• Retrofittable with MCB

6 - 63 A

6 kA

COMPACT VERSION

Page 3: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

3

CONTENTS

5 6

MCBs RCDs

MOD6PACKS

14

7ACCESSORIES

12

ACCESSORIES

11

PANELBOARDS

10

TECHNICAL DATA DIMENSIONS (mm) CURVES

MCBs ............................................16RCCBs ..........................................182 Pole RCBOs ..........................18Compact RCBOs ...................191 Pole RCBOs ..........................19Surge Diverters ......................22Panelboards .............................24

MCBs ............................................20RCCBs ...........................................201 & 2 Pole RCBOs ..................21Compact RCBOs ....................21Surge Diverters ......................23Panelboards .............................24Enclosures ................................25

MCBs .............................................26

RCBOs ..........................................27Compact RCBOs ...................27

ACCESSORIES

12

SURGE DIVERTERS

8

12

ENCLOSURES

12

MAIN SWITCHES

Page 4: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

4

The NHP MOD6 range of consumer switchboards and circuit protection are a flexible range of products designed

for domestic and commercial installations.

Page 5: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

5

6 kA 1 POLE MINIATURE CIRCUIT BREAKERS CATALOGUE NUMBER DESCRIPTION WIDTH

MOD6 1 06 MCB 6 kA 1 P 6 A C CURVE MOD6 1

MOD6 1 10 MCB 6 kA 1 P 10 A C CURVE MOD6 1

MOD6 1 16 MCB 6 kA 1 P 16 A C CURVE MOD6 1

MOD6 1 20 MCB 6 kA 1 P 20 A C CURVE MOD6 1

MOD6 1 25 MCB 6 kA 1 P 25 A C CURVE MOD6 1

MOD6 1 32 MCB 6 kA 1 P 32 A C CURVE MOD6 1

MOD6 1 40 MCB 6 kA 1 P 40 A C CURVE MOD6 1

MOD6 1 50 MCB 6 kA 1 P 50 A C CURVE MOD6 1

MOD6 1 63 MCB 6 kA 1 P 63 A C CURVE MOD6 1

6 kA 2 POLE MINIATURE CIRCUIT BREAKERS CATALOGUE NUMBER DESCRIPTION WIDTH

MOD6 2 06 MCB 6 kA 2 P 6 A C CURVE MOD6 2

MOD6 2 10 MCB 6 kA 2 P 10 A C CURVE MOD6 2

MOD6 2 16 MCB 6 kA 2 P 16 A C CURVE MOD6 2

MOD6 2 20 MCB 6 kA 2 P 20 A C CURVE MOD6 2

MOD6 2 25 MCB 6 kA 2 P 25 A C CURVE MOD6 2

MOD6 2 32 MCB 6 kA 2 P 32 A C CURVE MOD6 2

MOD6 2 40 MCB 6 kA 2 P 40 A C CURVE MOD6 2

MOD6 2 50 MCB 6 kA 2 P 50 A C CURVE MOD6 2

MOD6 2 63 MCB 6 kA 2 P 63 A C CURVE MOD6 2

6 kA 3 POLE MINIATURE CIRCUIT BREAKERS CATALOGUE NUMBER DESCRIPTION WIDTH

MOD6 3 06 MCB 6 kA 3 P 6 A C CURVE MOD6 3

MOD6 3 10 MCB 6 kA 3 P 10 A C CURVE MOD6 3

MOD6 3 16 MCB 6 kA 3 P 16 A C CURVE MOD6 3

MOD6 3 20 MCB 6 kA 3 P 20 A C CURVE MOD6 3

MOD6 3 25 MCB 6 kA 3 P 25 A C CURVE MOD6 3

MOD6 3 32 MCB 6 kA 3 P 32 A C CURVE MOD6 3

MOD6 3 40 MCB 6 kA 3 P 40 A C CURVE MOD6 3

MOD6 3 50 MCB 6 kA 3 P 50 A C CURVE MOD6 3

MOD6 3 63 MCB 6 kA 3 P 63 A C CURVE MOD6 3

MCBs

MOD6 1

MOD6 2

MOD6 3

Page 6: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

6

6 kA RCBOs (SAFETY SWITCH + MCB) 1 POLE

PANELBOARD MODEL*

CATALOGUE NUMBER DESCRIPTION WIDTH

MOD6 RCBO 1 1030 RCBO 6 kA 1 P 10 A 30 mA MOD6 1

MOD6 RCBO 1 1630 RCBO 6 kA 1 P 16 A 30 mA MOD6 1

MOD6 RCBO 1 2030 RCBO 6 kA 1 P 20 A 30 mA MOD6 1

MOD6 RCBO 1 2530 RCBO 6 kA 1 P 25 A 30 mA MOD6 1

MOD6 RCBO 1 3230 RCBO 6 kA 1 P 32 A 30 mA MOD6 1

LOADCENTRE AND PANELBOARD MODEL (COMPACT VERSION)

CATALOGUE NUMBER DESCRIPTION WIDTH

M6 RCBS 0630C RCBO 6 kA 1 P 06 A 30 mA MOD6 1

M6 RCBS 1030C RCBO 6 kA 1 P 10 A 30 mA MOD6 1

M6 RCBS 1630C RCBO 6 kA 1 P 16 A 30 mA MOD6 1

M6 RCBS 2030C RCBO 6 kA 1 P 20 A 30 mA MOD6 1

M6 RCBS 2530C RCBO 6 kA 1 P 25 A 30 mA MOD6 1

M6 RCBS 3230C RCBO 6 kA 1 P 32 A 30 mA MOD6 1

RCDs and MAIN SWITCHES

M6 RCBD

MOD6 RCBO 1

M6 RCBS

LOADCENTRE MODEL (COMPACT VERSION)

CATALOGUE NUMBER DESCRIPTION WIDTH

M6 RCBD 0630C RCBO 6 kA 1 P 06 A 30 mA MOD6 1

M6 RCBD 1030C RCBO 6 kA 1 P 10 A 30 mA MOD6 1

M6 RCBD 1630C RCBO 6 kA 1 P 16 A 30 mA MOD6 1

M6 RCBD 2030C RCBO 6 kA 1 P 20 A 30 mA MOD6 1

M6 RCBD 2530C RCBO 6 kA 1 P 25 A 30 mA MOD6 1

M6 RCBD 3230C RCBO 6 kA 1 P 32 A 30 mA MOD6 1

COMPACT M6 RCBD

Page 7: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

7

6 kA RCBOs (SAFETY SWITCH + MCB) 2 POLE *

CATALOGUE NUMBER DESCRIPTION WIDTH

MOD6 RCBO 2 1030 RCBO 6 kA 2 P 10 A 30 mA MOD6 2

MOD6 RCBO 2 1630 RCBO 6 kA 2 P 16 A 30 mA MOD6 2

MOD6 RCBO 2 2030 RCBO 6 kA 2 P 20 A 30 mA MOD6 2

MOD6 RCBO 2 2530 RCBO 6 kA 2 P 25 A 30 mA MOD6 2

MOD6 RCBO 2 3230 RCBO 6 kA 2 P 32 A 30 mA MOD6 2

RCCBs (SAFETY SWITCHES) *

CATALOGUE NUMBER DESCRIPTION WIDTH

MOD6 RCCB 2 4030 RCCB 6 kA 2 P 40 A 30 mA MOD6 2

MOD6 RCCB 2 6330 RCCB 6 kA 2 P 63 A 30 mA MOD6 2

MOD6 RCCB 4 4030 RCCB 6 kA 4 P 40 A 30 mA MOD6 4

MOD6 RCCB 4 6330 RCCB 6 kA 4 P 63 A 30 mA MOD6 4

MAIN SWITCHES (ISOLATORS)

CATALOGUE NUMBER DESCRIPTION WIDTH

MOD6 MS 1 80 MAIN SWITCH 1 P 80 A MOD6 1

MOD6 MS 1 100 MAIN SWITCH 1 P 100 A MOD6 1

MOD6 MS 2 100 MAIN SWITCH 2 P 100 A MOD6 2

MOD6 MS 3 100 MAIN SWITCH 3 P 100 A MOD6 3

MOD6 RCBO 2

MOD6 RCCB 4

MOD6 MS 1

IBD218P

DTTLT25PN2

IBD213P

ACCESSORIES FOR M6 RCBD

CATALOGUE NUMBER DESCRIPTION WIDTH

DTTLT25PN2 PIN TERMINAL 25 MM 1

IBD213P 13 WAY BUSBAR 1P+N 1

IBD218P 18 WAY BUSBAR 1P+N 1

IBD255P 55 WAY BUSBAR 1P+N 1

IBDEC2 ENCP SUIT IBD218P 1

* For Type A device please add A to end of Catalogue Number eg. MODRCB021030A

Page 8: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

[8]

SURGE DIVERTERS

SURGE DIVERTERS 1 POLE

MODULES CATALOGUE NUMBER DESCRIPTION (18MM WIDE)

MOD6-SD1-20-230 1P 20 kA MOD6 SURGE DIVERTER 1

MOD6-SD1-40-230 1P 40 kA MOD6 SURGE DIVERTER 1

SURGE DIVERTERS 2 POLE

MODULES CATALOGUE NUMBER DESCRIPTION (18MM WIDE)

MOD6-SD2-20-230 1P+N 20 kA MOD6 SURGE DIVERTER 2

MOD6-SD2-40-230 1P+N 40 kA MOD6 SURGE DIVERTER 2

SURGE DIVERTERS 4 POLE

MODULES CATALOGUE NUMBER DESCRIPTION (18MM WIDE)

MOD6-SD4-20-400 3P+N 20 kA MOD6 SURGE DIVERTER 4

MOD6-SD4-40-400 3P+N 40 kA MOD6 SURGE DIVERTER 4

• Standard IEC 61643-1 (Class 2)

• Status indication (via flag)

• DIN rail mounting

• Thermal disconnection

• Remote indication (via volt free contact)

Page 9: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

YOUR FIRST CHOICE

The brands you know & trust available through your local wholesaler.

Australian owned and with over 40 years of industry experience, NHP have the knowledge and expertise to service the electrical industry with quality products and solutions.

Sure to satisfy your domestic and commercial project needs, NHP can deliver the right product for the right

application from circuit protection and signaling equipment through to pushbuttons and enclosures.

When it comes to your electrical product and solution needs, make NHP your first choice.

Page 10: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

10

M6PB36

M6PB36M160

Refer page 11 for accessory modules, flush kits and gear trays

PANELBOARDS NO MAINSWITCH (SUITS MOD6 MCB AND RCBOs)

POLE CAP BOX SIZE HEIGHT (MM) CATALOGUE NUMBER

24 1 650 M6PB24

36 2 750 M6PB36 48 3 850 M6PB48

60 4 950 M6PB60

84 5 1200 M6PB84

PANELBOARDS 160 A MAINSWITCH(SUITS MOD6 MCB AND RCBOs)

POLE CAP BOX SIZE HEIGHT (MM) CATALOGUE NUMBER

24 1 650 M6PB24M160

36 2 750 M6PB36M160 48 3 850 M6PB48M160

60 4 950 M6PB60M160

84 5 1200 M6PB84M160

PANELBOARDS 250 A MAINSWITCH (SUITS MOD6 MCB AND RCBOs)

POLE CAP BOX SIZE HEIGHT (MM) CATALOGUE NUMBER

24 1 650 M6PB24M250

36 2 750 M6PB36M250

48 3 850 M6PB48M250

60 4 950 M6PB60M250

84 5 1200 M6PB84M250

PANELBOARDS

• Standard AS / NZS 3439.3

• Compact 160 A or 250 A main switch

• Neutral colour scheme - Oyster grey (RAL 7035)

• The door and escutcheon are field changeable from right to left hand hinged

• Accessory modules

• 16 modules extra DIN equipment

Page 11: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

11

M6ACCS0

Flush Kit

PANELBOARD ACCESSORIES

ACCESSORIES

CATALOGUE NUMBER DESCRIPTION

IBC112P 12 WAY SINGLE PHASE PIN BUSBAR

IBC118P 18 WAY SINGLE PHASE PIN BUSBAR

ICL102 10 WAY TWO PHASE PIN BUSBAR

ICL123 12 WAY THREE PHASE PIN BUSBAR

ICL183 18 WAY THREE PHASE PIN BUSBAR

DTPF POLE FILLER - 4 MODULES

DTTAX16PN3 3 WAY NEUTRAL LINK SUIT RCCB

ICL561F 57 WAY SINGLE PHASE FORK BUSBAR

DTLD LOCK DOG (NON-CAPTIVE)

CPELK1W EMERGENCY LIGHTING KIT

Accessory modules(SUITS MOD6 MCB AND RCBOs)

POLE CAP BOX SIZE HEIGHT (MM) CATALOGUE NUMBER

- 0 400 M6ACCS0*

- 1 650 M6ACCS1*

- 2 750 M6ACCS2*

- 3 850 M6ACCS3*

- 4 950 M6ACCS4*

- 5 1200 M6ACCS5*

21 0 400 M6ACC21

42 0 400 M6ACC42

63 1 650 M6ACC63

DTTAX16PN3

DTLD

BOX SIZE CATALOGUE NUMBER

0 M6PBFK0

1 M6PBFK1

2 M6PBFK2

3 M6PBFK3

4 M6PBFK4

5 M6PBFK5

BOX SIZE CATALOGUE NUMBER

0 M6PBGTS0

1 M6PBGTS1

2 M6PBGTS2

3 M6PBGTS3

4 M6PBGTS4

5 M6PBGTS5

FLUSH KITS GEAR TRAYS

* complete with gear tray and blank escutcheon

IBC112P

Page 12: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

12

ENCLOSURES (SWITCHBOARD) IP 40

POLE COVERS

DESCRIPTION CATALOGUE NUMBER

POLE COVER 1P DIN CSPC1

POLE COVER 2P DIN CSPC2

POLE COVER 4P DIN CSPC4

No Earth or Neutral bars

DIMENSIONS

WIDTH (W) HEIGHT (H) DEPTH (D) CATALOGUE NUMBER

32 mm 130 mm 62 mm CSPC1

50 mm 130 mm 62 mm CSPC2

86 mm 130 mm 62 mm CSPC4

185 mm 130 mm 94 mm CSB08

LOADCENTRES

DESCRIPTION CATALOGUE NUMBER

8 WAY SURFACE TRANSPARENT DOOR CSB08ST

8 WAY SURFACE WHITE DOOR CSB08SW Split neutral bar - 4/4 earth bar - 8 way

Comes with busbar comb

Page 13: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

13

CSB-12-SW

CSB-18-SW

CSB-24-SW

CSB-36-SW

12 WAY *

CATALOGUE NUMBER DESCRIPTION

CSB-12-ST 12 WAY SURFACE TRANSPARENT DOOR

CSB-12-SW 12 WAY SURFACE WHITE DOOR

CSB-12-FT 12 WAY FLUSH TRANSPARENT DOOR

CSB-12-FW 12 WAY FLUSH WHITE DOOR

Split neutral bar - 5 / 3 / 3 Earth bar - 12 way

18 WAY *

CATALOGUE NUMBER DESCRIPTION

CSB-18-ST 18 WAY SURFACE TRANSPARENT DOOR

CSB-18-SW 18 WAY SURFACE WHITE DOOR

CSB-18-FT 18 WAY FLUSH TRANSPARENT DOOR

CSB-18-FW 18 WAY FLUSH WHITE DOOR

Split neutral bar - 9 / 3 / 3 / 3 Earth bar - 18 way

24 WAY *

CATALOGUE NUMBER DESCRIPTION

CSB-24-ST 24 WAY SURFACE TRANSPARENT DOOR

CSB-24-SW 24 WAY SURFACE WHITE DOOR

CSB-24-FT 24 WAY FLUSH TRANSPARENT DOOR

CSB-24-FW 24 WAY FLUSH WHITE DOOR

Split neutral bar - 10 / 3 / 3 / 3 / 3 Earth bar - 24 way

36 WAY *

CATALOGUE NUMBER DESCRIPTION

CSB-36-ST 36 WAY SURFACE TRANSPARENT DOOR

CSB-36-SW 36 WAY SURFACE WHITE DOOR

CSB-36-FT 36 WAY FLUSH TRANSPARENT DOOR

CSB-36-FW 36 WAY FLUSH WHITE DOOR

Split neutral bar - 12 / 12 / 12 Earth bar - 36 way

METAL BACKING PLATES (for flush enclosure - mechanical protection)**

CAT. NO. DESCRIPTION

CSB-12-FMPL FLUSH MOUNT PLATE 12 WAY LONG

CSB-18-FMPL FLUSH MOUNT PLATE 18 WAY LONG

CSB-24-FMPL FLUSH MOUNT PLATE 24 WAY LONG

CSB-36-FMPL FLUSH MOUNT PLATE 36 WAY LONG * Switchboards supplied complete with busbar comb **For short version delete L. e.g. CSB12FMP

ENCLOSURES (SWITCHBOARD) IP 40

Page 14: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

14

MAINSWITCH - ISOLATOR

MOD612PKV1 DESCRIPTION CAT. NO. QTY

12 WAY SURFACE MOUNT CSB-12-ST 1

1 P 80 A MAIN SWITCH MOD6 MS1 80 1

MCB 6 kA 1 P 16 A MOD6 1 16 2

MCB 6 kA 1 P 10 A MOD6 1 10 2

RCCB 6 kA 2 P 40 A 30 mA MOD6 RCCB 2 40 30 1

MOD612PKV3

DESCRIPTION CAT. NO. QTY

12 WAY SURFACE MOUNT CSB-12-ST 1

1 P 80 A MAIN SWITCH MOD6 MS1 80 1

RCBO 6 kA 1 P 16 A 30 mA M6 RCBS 1630C 3

RCBO 6 kA 1 P 10 A 30 mA M6 RCBS 1030C 2

MOD612PKV2 12 WAY SURFACE MOUNT CSB-12-ST 1

1 P 80 A MAIN SWITCH MOD6 MS1 80 1

MCB 6 kA 1 P 16 A MOD6 1 16 3

MCB 6 kA 1 P 10 A MOD6 1 10 2

RCCB 6 kA 2 P 40 A 30 mA MOD6 RCCB 2 40 30 2

MOD618PKV1 18 WAY SURFACE MOUNT CSB-18-ST 1

1 P 80 A MAIN SWITCH MOD6 MS1 80 1

MCB 6 kA 1 P 32 A MOD6 1 32 1

MCB 6 kA 1 P 16 A MOD6 1 16 4

RCCB 6 kA 2 P 40 A 30 mA MOD6 RCCB 2 40 30 1

RCBO 6 kA 2 P 10 A 30 mA MOD6 RCBO 2 10 30 1

MOD618PKV2 18 WAY SURFACE MOUNT CSB-18-ST 1

1 P 80 A MAIN SWITCH MOD6 MS1 80 1

MCB 6 kA 1 P 32 A MOD6 1 32 1

MCB 6 kA 1 P 16 A MOD6 1 16 5

RCCB 6 kA 2 P 40 A 30 mA MOD6 RCCB 2 40 30 2

RCBO 6 kA 2 P 10 A 30 mA MOD6 RCBO 2 10 30 2 For flush mount versions add ‘F’ to the end of the part number when ordering.

NHPs flexible range of competitively priced standard switchboards in one easy to order part number.

FLUSH OR SURFACE MOUNT

FAULT RATING OF 6 kAWHITE OR TRANSPARENT DOORS

12 &18 POLE

MOD6PACKS

a

a a

a

MOD612PKV2T 12 WAY SURFACE MOUNT CSB-12-ST 1

1 P 80 A MAIN SWITCH MOD6 MS1 80 1

MCB 6 kA 1 P 20 A MOD6 1 20 3

MCB 6 kA 1 P 10 A MOD6 1 10 2

RCCB 6 kA 2 P 40 A 30 mA MOD6 RCCB 2 40 30 2

Page 15: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

15

MAINSWITCH - MCB 63 A

For flush mount versions add ‘F’ to the end of the part number when ordering.

ENCLOSURESMAIN SWITCH

& RCDs MCBs

MOD612PK1 DESCRIPTION CAT. NO. QTY

12 WAY SURFACE MOUNT LOADCENTRE CSB-12-ST 1

MCB 6 kA 1 P 63 A main switch MOD6 1 63 1

MCB 6 kA 1 P 16 A MOD6 1 16 2

MCB 6 kA 1 P 10 A MOD6 1 10 2

RCCB 6 kA 2 P 40 A 30 mA MOD6 RCCB 2 40 30 1

MOD612PK2 12 WAY SURFACE MOUNT LOADCENTRE CSB-12-ST 1

MCB 6 kA 1 P 63 A main switch MOD6 1 63 1

MCB 6 kA 1 P 16 A MOD6 1 16 3

MCB 6 kA 1 P 10 A MOD6 1 10 2

RCCB 6 kA 2 P 40 A 30 mA MOD6 RCCB 2 40 30 2

MOD612PK3 12 WAY SURFACE MOUNT LOADCENTRE CSB-12-ST 1

MCB 6 kA 1 P 63 A main switch MOD6 1 63 1

RCBO 6 kA 1 P 16 A 30 mA M6 RCBS 1630C 3

RCBO 6 kA 1 P 10 A 30 mA M6 RCBS 1030C 2

MOD618PK1 DESCRIPTION CAT. NO. QTY

18 WAY SURFACE MOUNT LOADCENTRE CSB-18-ST 1

MCB 6 kA 1 P 63 A main switch MOD6 1 63 1

MCB 6 kA 1 P 32 A MOD6 1 32 1

MCB 6 kA 1 P 16 A MOD6 1 16 4

RCCB 6 kA 2 P 40 A 30 mA MOD6 RCCB 2 40 30 1

RCBO 6 kA 2 P 10 A 30 mA MOD6 RCBO 2 10 30 1

MOD618PK2 18 WAY SURFACE MOUNT LOADCENTRE CSB-18-ST 1

MCB 6 kA 1 P 63 A main switch MOD6 1 63 1

MCB 6 kA 1 P 32 A MOD6 1 32 1

MCB 6 kA 1 P 16 A MOD6 1 16 5

RCCB 6 kA 2 P 40 A 30 mA MOD6 RCCB 2 40 30 2

RCBO 6 kA 2 P 10 A 30 mA MOD6 RCBO 2 10 30 2

Page 16: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

16

TECHNICAL DATA (MCBs)

Approval No. N17481Standards AS/NZS 60898 Tripping characteristics C Nominal current 6 - 63 A Calibration temperature 30 oC Number of poles 1 / 2 / 3 Nominal voltage AC 1 P 240 VAC 2 P / 3 P 415 VDC 1 P 48 V DCDC 2 P (poles in series) 110 V DCFrequency 50/60 Hz Max voltage between two wires 250/440 V Min service voltage 12 V Dielectric class 3 Isolation application (AS/NZS 60947-2) Yes Rated insulation voltage pollution degree 2 500 V pollution degree 3 400 V Impulse withstand test voltage 6 kV Insulation resistance (Mohm) 10,000 Dielectric rigidity (V) 2.500 Vibration resistance 3 g Endurance (operations) electrical 10,000 mechanical 20,000 Utilisation category A Protection degree outside enclosure IP 20 inside enclosure IP 40 Self extinguishing degree (UL94) V 2 Tropicalisation (IEC 60068-2) °C/RH +55 / 95 % Operating temperature -25 / +55 oC Storage temperature -55 / +55 oCTemperature derating Refer NHP Terminal capacity (top and bottom) min / max 1 / 25 mm Terminal torque 4.5 Nm Busbar systems Fork or Pin Accessories No Dimensions (mm) 76 (H) 86 (L) 18 (W) Weight 120 g per pole

SHORT CIRCUIT CAPACITY AC IN kAIcn 1 P 6 2 P 6 3 P 6 Ics 100 % Icu

1 P, 2 P & 3 P MCBs

Page 17: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

PLUGS & SOCKETS FOR ANY APPLICATION

Available at your local Gemcell branch.

*Deconnector is a trademark of NHP.

Industrial Plugs and Sockets:For all your industrial, commercial and

domestic single and three phase applications think ISO plugs and sockets.

The ISO range is available in 10 A to 50 A; 3, 4 and 5 pin configurations.

*Deconnector™ Plugs and Sockets:Proconect is a world leader in

industrial plugs and sockets for manufacturing, commercial

and arduous industries.The 3PS isolating plugs from Proconect are

available in five sizes from 16 A to 200 A.

CAUTION WIDE RANGE

AHEAD

Visit http://www.nhp.com.au/ Page/Media/Catalogues-and-Literature/Brochures /Plugs-and-Sockets or scan the QR code to the left to download your FREE copy of the Plugs & Sockets catalogue today.

Page 18: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

18

RCCBs 2 POLE RCBOs 1 POLE RCBOs 1 POLE RCBSs 1 POLE RCBDs

Approval No. N17482 N17482 N21915 NSW24576 NSW24576

Standards AS/NZS 61008 - 1 AS/NZS 61009 - 1 AS/NZS 61009 - 1 AS/NZS 61009 - 1 AS/NZS 61009 - 1

Magnetic tripping characteristics - C C C C

Residual tripping characteristics AC AC AC AC AC

Rated current (A) 40 - 63 10 - 32 10 - 32 6 - 32 6 - 32

Rated residual current 30 mA 30 mA 30 mA 30 mA 30 mA

Calibration temperature 30 oC 30 oC 30 oC 30 oC 30 oC

Rated voltage 2 P 240 V 240 V 240 V (1 P) 240 V (1 P) 240 V (1 P) 4 P 415 V - - - -

Frequency (HZ) 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60

Maximum service voltage 2 P=265, 4 P=455 255 255 255 255

Minimum service voltage 2 P=110, 4 P=190 100 100 85 85

Power supply (line side) Top / Bottom Top / Bottom Bottom Bottom Bottom

Selectivity class - 3 3 3 3

Residual making and breaking capacity 500 A 6 kA 6 kA 3 kA 3 kA

Short circuit capacity - 6 kA 6 kA 6 kA 6 kA

Isolation application (IEC 60947-2) Yes Yes Yes Yes Yes

Insulation resistance (Mohm) 1,000 1,000 1,000 1,000 1,000

Insulation voltage (V) 500 500 500 500 500

Dielectric rigidity (V) 2,500 2,500 2,500 2,500 2,500

Vibration resistance 1.5 g 1.5 g 1.5 g 1.5 g 1.5 g

Endurance (operations) electrical 10,000 10,000 10,000 10,000 10,000 mechanical 20,000 20,000 20,000 20,000 20,000

Protection degree outside IP 20 IP 20 IP 20 IP 20 IP 20 inside enclosure IP 40 IP 40 IP 40 IP 40 IP 40

Self extinguishing degree (UL 94) V 2 V 2 V 2 V 2 V 2

Tropicalisation (IEC 60068-2) +55 oC / 95 % RH +55 oC / 95 % RH +55 oC / 95 % RH +55 oC / 95 % RH +55 oC / 95 % RH

Operating temperature -5 / +55 oC -5 / +55 oC -5 / +55 oC -5 / +55 oC -5 / +55 oC

Storage temperature -25 / +70 oC -25 / +70 oC -25 / +70 oC -25 / +70 oC -25 / +70 oC

Terminal capacity (top & bottom) min / max 1.5 / 50 mm 1 / 25 mm 1 / 25 mm 1 / 16 & 1 / 25 mm 1 / 16 & 1 / 16 mm

Terminal torque (top / bottom) (Nm) 5 / 5 3 / 4 3 / 3 3 / 3 3 / 3

Busbar systems Yes Yes Yes Yes Yes

Accessories No No No No No

Dimensions (mm) 76 (H) 86 (L) 36/72 (W) 76 (H) 86 (L) 36 (W) 76 (H) 112 (L) 18 (W) 76 (H) 86 (L) 18 (W) 76 (H) 86 (L) 18 (W)

Weight (g) 2 P=250, 4 P=368 250 350 125 125

TECHNICAL DATA (RCDs)

Page 19: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

19

RCCBs 2 POLE RCBOs 1 POLE RCBOs 1 POLE RCBSs 1 POLE RCBDs

Approval No. N17482 N17482 N21915 NSW24576 NSW24576

Standards AS/NZS 61008 - 1 AS/NZS 61009 - 1 AS/NZS 61009 - 1 AS/NZS 61009 - 1 AS/NZS 61009 - 1

Magnetic tripping characteristics - C C C C

Residual tripping characteristics AC AC AC AC AC

Rated current (A) 40 - 63 10 - 32 10 - 32 6 - 32 6 - 32

Rated residual current 30 mA 30 mA 30 mA 30 mA 30 mA

Calibration temperature 30 oC 30 oC 30 oC 30 oC 30 oC

Rated voltage 2 P 240 V 240 V 240 V (1 P) 240 V (1 P) 240 V (1 P) 4 P 415 V - - - -

Frequency (HZ) 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60

Maximum service voltage 2 P=265, 4 P=455 255 255 255 255

Minimum service voltage 2 P=110, 4 P=190 100 100 85 85

Power supply (line side) Top / Bottom Top / Bottom Bottom Bottom Bottom

Selectivity class - 3 3 3 3

Residual making and breaking capacity 500 A 6 kA 6 kA 3 kA 3 kA

Short circuit capacity - 6 kA 6 kA 6 kA 6 kA

Isolation application (IEC 60947-2) Yes Yes Yes Yes Yes

Insulation resistance (Mohm) 1,000 1,000 1,000 1,000 1,000

Insulation voltage (V) 500 500 500 500 500

Dielectric rigidity (V) 2,500 2,500 2,500 2,500 2,500

Vibration resistance 1.5 g 1.5 g 1.5 g 1.5 g 1.5 g

Endurance (operations) electrical 10,000 10,000 10,000 10,000 10,000 mechanical 20,000 20,000 20,000 20,000 20,000

Protection degree outside IP 20 IP 20 IP 20 IP 20 IP 20 inside enclosure IP 40 IP 40 IP 40 IP 40 IP 40

Self extinguishing degree (UL 94) V 2 V 2 V 2 V 2 V 2

Tropicalisation (IEC 60068-2) +55 oC / 95 % RH +55 oC / 95 % RH +55 oC / 95 % RH +55 oC / 95 % RH +55 oC / 95 % RH

Operating temperature -5 / +55 oC -5 / +55 oC -5 / +55 oC -5 / +55 oC -5 / +55 oC

Storage temperature -25 / +70 oC -25 / +70 oC -25 / +70 oC -25 / +70 oC -25 / +70 oC

Terminal capacity (top & bottom) min / max 1.5 / 50 mm 1 / 25 mm 1 / 25 mm 1 / 16 & 1 / 25 mm 1 / 16 & 1 / 16 mm

Terminal torque (top / bottom) (Nm) 5 / 5 3 / 4 3 / 3 3 / 3 3 / 3

Busbar systems Yes Yes Yes Yes Yes

Accessories No No No No No

Dimensions (mm) 76 (H) 86 (L) 36/72 (W) 76 (H) 86 (L) 36 (W) 76 (H) 112 (L) 18 (W) 76 (H) 86 (L) 18 (W) 76 (H) 86 (L) 18 (W)

Weight (g) 2 P=250, 4 P=368 250 350 125 125

Page 20: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

20

DIMENSIONS IN MM (MCBs)

2 pole 4 pole

DIMENSIONS IN MM (RCCBs)

Page 21: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

21

DIMENSIONS IN MM(RCBOs)

1 pole 2 pole

DIMENSIONS IN MM (COMPACT RCBOs)

M6 RCBS M6 RCBD

Page 22: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

22

TECHNICAL DATA (SURGE DIVERTERS)

MOD6-SD1-20-230 MOD6-SD1-40-230 MOD6-SD2-20-230

EN61643-11 / IEC61643-1 Type 2 / Class 2 Type 2 / Class 2 Type 2 / Class 2

Nominal Voltage 230 V 230 V 230/400 V

Maximum Continuous operating voltage(L-N) 320 V 275 V 320 V

Maximum Continuous operating voltage(N-PE) - - 255 V

Maximum discharge current 20 kA 40 kA 20 kA

Nominal discharge current 10 kA 20 kA 10 kA

Voltage protection level (L-N) ≤1.4 kV ≤1.3 kV ≤1.4 kV

Voltage protection level (N-PE) - - ≤1.5 kV

Maximum backup fuse 63 A 80 A 63 A

Short circuit withstand 25 kA 25 kA 25 kA

Response time (L-N) 25 ns 25 ns 25 ns

Response time (N-PE) - - 100 ns

Remote monitoring Included in all models

End of life indication Included in all models

MOD6-SD2-40-230 MOD6-SD4-20-400 MOD6-SD4-40-400

EN61643-11 / IEC61643-1 Type 2 / Class 2 Type 2 / Class 2 Type 2 / Class 2

Nominal Voltage 230/400 V 230/400 V 230/400 V

Maximum Continuous operating voltage(L-N) 275 V 320 V 275 V

Maximum Continuous operating voltage(N-PE) 265 V 255 V 265 V

Maximum discharge current 40 kA 20 kA 40 kA

Nominal discharge current 20 kA 10 kA 20 kA

Voltage protection level (L-N) ≤1.3 kV ≤1.4 kV ≤1.3 kV

Voltage protection level (N-PE) ≤1.5 kV ≤1.5 kV ≤1.5 kV

Maximum backup fuse 80 A 63 A 80 A

Short circuit withstand 25 kA 25 kA 25 kA

Response time (L-N) 25 ns 25 ns 25 ns

Response time (N-PE) 100 ns 100 ns 100 ns

Remote monitoring Included in all models

End of life indication Included in all models

Page 23: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

23

DIMENSIONS IN MM (SURGE DIVERTERS)

SURGE DIVERTERS 1 POLE

SURGE DIVERTERS 2 POLE

SURGE DIVERTERS 4 POLE

MOD6-SD1-20-230

MOD6-SD1-40-230

MOD6-SD2-20-230

MOD6-SD2-40-230

MOD6-SD4-20-400

MOD6-SD4-40-400

Page 24: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

24

TECHNICAL DATA AND DIMENSIONS IN MM (PANELBOARDS)

Size 1 650 2 750 3 850 4 950 5 1200

530 131 20

400

530 131 20

Material type 1 mm steelFinish Polyester powder coated Colour Oyster grey (RAL 7035) Protection degree IP 30 without door IP 40 with door Busbar ratings 250 A 20 kA for 0.2 secondsMain switches 160 A 3 pole 415 V AC top mount 250 A 3 pole 415 V AC top mount

Size 1 650 2 750 3 850 4 950 5 1200

530 131 20

400

530 131 20

Size 1 650 2 750 3 850 4 950 5 1200

530 131 20

400

530 131 20

ACCESSORY MODULE FLUSH KIT

Page 25: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

25

DIMENSIONS IN MM (ENCLOSURES)

H

W

H

W

HH

W

D

12 WAYENCLOSURE TYPE WIDTH (W) HEIGHT (H) DEPTH (D)

SURFACE 256 200 97FLUSH - BASE 270 211 66FLUSH - COVER 304 246 29

18 WAYENCLOSURE TYPE WIDTH (W) HEIGHT (H) DEPTH (D)

SURFACE 363 220 97FLUSH - BASE 380 232 76FLUSH - COVER 412 267 29

24 WAYENCLOSURE TYPE WIDTH (W) HEIGHT (H) DEPTH (D)

SURFACE 269 326 97FLUSH - BASE 270 304 76FLUSH - COVER 305 358 29

36 WAYENCLOSURE TYPE WIDTH (W) HEIGHT (H) DEPTH (D)

SURFACE 306 473 102FLUSH - BASE 308 470 76FLUSH - COVER 342 503 29

FLUSH ENCLOSURE - CUTOUT DIMENSIONS

ENCLOSURE TYPE WIDTH (W) HEIGHT (H)

12 WAY 259 19918 WAY 365 213

ENCLOSURE TYPE WIDTH (W) HEIGHT (H)

24 WAY 259 31136 WAY 296 458

Page 26: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

26

TIME/CURRENT I2t LET THROUGH ENERGY

Ip LIMITED PEAK CURRENT

CURVES (MCBs)

Page 27: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

27

I2t LET THROUGH ENERGY 1 AND 2 POLE RCBOs

I2t 1 POLE COMPACT RCBOs AT 230 V

CURVES (RCBOs)

CURVES (COMPACT RCBOs)

Page 28: Consumer Switchboards and Circuit Protection - NHP · PDF filePOWER DISTRIBUTION AND PROTECTION Consumer Switchboards and Circuit Protection Flexible range designed for domestic and

AUSTRALIAnhp.com.au

SALES 1300 NHP NHP

[email protected]

VICTORIA

Melbourne 43-67 River Street Richmond VIC 3121 Tel +61 3 9429 2999

Laverton 104-106 William Angliss Drive Laverton North VIC 3026 Tel +61 3 9368 2901

Dandenong Unit 1/80 Monash Drive Dandenong South VIC 3175 Tel +61 3 8773 6400 Fax 1300 647 329

TASMANIA

Hobart 29B Lampton Ave Derwent Park TAS 7009 Tel +61 3 6228 9575 Fax +61 3 6228 9757

Launceston Unit 3 13-17 Merino Street Kings Meadows TAS 7249 Tel +61 3 6345 2600 Fax +61 3 6344 6324

SOUTH AUSTRALIA

Adelaide 36-38 Croydon Road Keswick SA 5035 Tel +61 8 8297 9055

NEW SOUTH WALES

Sydney 30-34 Day Street North Silverwater NSW 2128 Tel +61 2 9748 3444

Newcastle 575 Maitland Road Mayfield West NSW 2304 Tel +61 2 4960 2220 Fax +61 2 4960 2203

Wollongong Unit 3 1 Resolution Drive Unanderra NSW 2526 Tel 1300 647 647 Fax 1300 647 329

Albury / Wodonga 847 Ramsden Drive Albury NSW 2640 Tel +61 2 6049 0600 Fax +61 3 6025 0592

ACT

Canberra Unit 1 187 Gladstone Street Fyshwick ACT 2609 Tel +61 2 6280 9888 Fax +61 2 6280 9588

WESTERN AUSTRALIA

Perth 38 Belmont Ave Rivervale WA 6103 Tel +61 8 9277 1777

NORTHERN TERRITORY

Darwin 3 Steele Street Winnellie NT 0820 Tel +61 8 8947 2666 Fax +61 8 8947 2049

QUEENSLAND

Brisbane 16 Riverview Place Murarrie QLD 4172 Tel +61 7 3909 4999

Townsville 5 Leyland Street Garbutt QLD 4814 Tel +61 7 4779 0700 Fax +61 7 4775 1457

Rockhampton 1 Lawson Street Parkhurst QLD 4702 Tel +61 7 4927 2277 Fax +61 7 4922 2947

Toowoomba Cnr Carroll Street and Struan Court QLD 4350 Tel +61 7 4634 4799 Fax +61 7 4633 1796

Cairns Unit 2 1 Bramp Close Portsmith QLD 4870 Tel +61 7 4035 6888 Fax +61 7 4035 6999

NEW ZEALANDnhp-nz.com

SALES 0800 NHP NHP

[email protected]

PO Box 62-009 Sylvia Park Auckland 1644 New Zealand

Auckland 118a Carbine Road Mt Wellington 1060

Hamilton 78 Rostrevor Street Hamilton 3204

Napier 126 Taradale Road Onekawa 4110

Wellington Unit B4, 59 Marsden Street Melling Lower Hutt 5010

Christchurch 27 Iversen Terrace Waltham 8011

Dunedin 30 Fox StreetSouth Dunedin 9012

For more information, scan to download the NHP eCatalogues App o�ering exclusive video content, catalogues and literature!

NHP Electrical Engineering Products Pty LtdA.B.N. 84 004 304 812

NHPMOD6PLAUS 9/15 © Copyright NHP 2015