Metalux Safe and convenient means of disconnecting power Catalog # Type Date Project Comments Prepared by SPECIFICATION FEATURES Construction Housing consists of die formed cold rolled steel with decorative white opaque injection molded end plates. Reflector/channel wireway cover secured by fasteners for easy wireway access. Channel back has numerous KO’s for easy installation. Controls The SWLED is Powered by Fifth Light, with a standard 0-10V continuous dimming driver that works with any 0-10V control/ dimmer. Combine with energy saving products like occupancy sensors, daylighting controls and lighting relay panels to maximize energy savings. In addition, the SWLED can include a factory- installed integrated sensor system for occupancy and daylight dimming control and manual control from an optional handheld remote. Or, specify the Digital Addressable Lighting Interface (DALI) drivers (consult factory for 1% dimming), for use with Fifth Light controls. See ordering information for details on all three options. Electrical Long-Life LED system coupled with electrical driver to deliver optimal performance. LED’s available in 3500K, 4000K or 5000K with a typical CRI 85. Projected life is 60,000 hours at 70% lumen output. Electronic drivers are available for 120-277V applications. A 0-10V dimming driver is standard. Emergency Battery Pack Option Optional 120v-277v integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 90-minute batteries provide constant power to the LED system, ensuring code- compliance. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. See ordering information for details. Finish Highly reflective post painted finish (PAF) standard offering customers the optimal finish and handling. Additionally, each housing is treated in a multistage iron phosphate pretreatment, insuring maximum bonding and rust inhibitor. Shielding Specially designed LED lens blends and linear optics allows us to offer three different lens versions - LC (clear), LN (Semi-Frost with narrow distribution) and LW (full frost with wide distribution). This lenses provide different lighting distribution allowing customers to choice between smooth even illumination. Lens is securely held in place by removable injection molded white end caps that can be easily removed for installation and maintenance. Installation Fixture may be surface (wall or ceiling) and suspended mounted. See accessories below for ordering information. Compliance Modules are UL recognized components and indoor luminaires are cULus listed for up to 40ºC ambient environments, RoHS compliant, and LED modules comply with IESNA LM-79 and LM-80 standards. DesignLights Consortium™ Qualified and classified for DLC Standard, refer to www.designlights.org for details. SWLED LED Surface and Wall LED ADF142352 2016-09-27 07:58:10 SWLED is a versatile LED surface or wall mount luminaire which can be used in a broad range of commercial and industrial applications. This series provides customers with a high quality luminaire utilizing the latest LED, solid state lighting and electronic driver technology for optimal performance and maximized energy efficiency. Offered with three different lens distributions and three different lens options which provides uniform light distribution that is an ideal choice for general purpose lighting where customers want to move away from traditional fluorescent solutions. DESCRIPTION CERTIFICATION DATA cULus - 1598 Damp Location Listed LM79/LM80 Compliant ROHS Compliant DesignLights Consortium™ Qualified NOM Compliant 4-11/16" [120mm] 4-1/2" [114mm] 4-11/16" [120mm] 52" [1320mm] 45-3/16" [1148mm] Lensed 4' 2' 4-11/16" [120mm] 21-3/16" [538mm] Lensed 28" [711mm] MOUNTING DATA D E S I G N J O U R N A L PLATINUM 2016

Upload: vankiet

Post on 10-Jul-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

Metalux

Safe and convenient means of disconnecting power

Catalog # Type

Date

Project

Comments

Prepared by

SPECIFICATION FEATURES

ConstructionHousing consists of die formed cold rolled steel with decorative white opaque injection molded end plates. Reflector/channel wireway cover secured by fasteners for easy wireway access. Channel back has numerous KO’s for easy installation.

ControlsThe SWLED is Powered by Fifth Light, with a standard 0-10V continuous dimming driver that works with any 0-10V control/ dimmer. Combine with energy saving products like occupancy sensors, daylighting controls and lighting relay panels to maximize energy savings. In addition, the SWLED can include a factory-installed integrated sensor system for occupancy and daylight dimming control and manual control from an optional handheld remote. Or, specify the Digital Addressable Lighting Interface (DALI) drivers (consult factory for 1% dimming), for use with Fifth Light controls. See ordering information for details on all three options.

ElectricalLong-Life LED system coupled with electrical driver to deliver optimal performance. LED’s available in 3500K, 4000K or 5000K with a typical CRI 85. Projected life is 60,000 hours at 70% lumen output. Electronic drivers are available for 120-277V applications. A 0-10V dimming driver is standard.

Emergency Battery Pack OptionOptional 120v-277v integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 90-minute batteries provide constant powerto the LED system, ensuring code-compliance. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. See ordering information for details.

FinishHighly reflective post painted finish (PAF) standard offering customers the optimal finish and handling. Additionally, each housing is treated in a multistage iron phosphate pretreatment, insuring maximum bonding and rust inhibitor.

ShieldingSpecially designed LED lens blends and linear optics allows us to offer three different lens versions

- LC (clear), LN (Semi-Frost with narrow distribution) and LW (full frost with wide distribution). This lenses provide different lighting distribution allowing customers to choice between smooth even illumination. Lens is securely held in place by removable injection molded white end caps that can be easily removed for installation and maintenance.

Instal lationFixture may be surface (wall or ceiling) and suspended mounted. See accessories below for ordering information.

ComplianceModules are UL recognized components and indoor luminaires are cULus listed for up to 40ºC ambient environments, RoHS compliant, and LED modules comply with IESNA LM-79 and LM-80 standards. DesignLights Consortium™ Qualified and classified for DLC Standard, refer to www.designlights.org for details.

SWLEDLED

Surface and Wal l LED

ADF1423522016-09-27 07:58:10

SWLED is a versatile LED surface or wall mount luminaire which can be used in a broad range of commercial and industrial applications.This series provides customers with a high quality luminaire utilizing the latest LED, solid state lighting and electronic driver technology for optimal performance and maximized energy efficiency. Offered with three different lens distributions and three different lens options which provides uniform light distribution that is an ideal choice for general purpose lighting where customers want to move away from traditional fluorescent solutions.

DESCRIPTION

C E R T I F I C A T I O N D A T AcULus - 1598

Damp Location Listed

LM79/LM80 Compliant

ROHS Compliant

DesignLights Consortium™ Qualified

NOM Compliant

4-11/16"[120mm]

4-1/2" [114mm]

4-11/16"[120mm]

52" [1320mm]

45-3/16" [1148mm]Lensed

4'

2'

4-11/16"[120mm]

21-3/16" [538mm]Lensed

28" [711mm]

MOUNTING DATA

D

E S I G N J O U R N A L

PLATINUM2 0 1 6

Specifications and dimensions subject to change without notice.

Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting

SWLED

ADF1423522016-09-27 07:58:10

Lens TypeLumen Type

Length Catalog LogicNominal Lumens

Wattage lm/W

Full Frost (LW) Standard 2 ft. 2SWLED-LD4-8SL-LW-UNV-L8XX-CD1-SVPD2-U 800 10.1 105

Full Frost (LW) Standard 2 ft. 2SWLED-LD4-16SL-LW-UNV-L8XX-CD1-SVPD2-U 1600 18.9 99.5

Full Frost (LW) Standard 2 ft. 2SWLED-LD4-20SL-LW-UNV-L8XX-CD1-SVPD2-U 2000 23.5 92

Full Frost (LW) High 2 ft. 2SWLED-LD4-24HL-LW-UNV-L8XX-CD1-SVPD2-U 2400 24.9 94.5

Full Frost (LW) High 2 ft. 2SWLED-LD4-28HL-LW-UNV-L8XX-CD1-SVPD2-U 2800 29.1 89.5

Full Frost (LW) Standard 4 ft. 4SWLED-LD4-16SL-LW-UNV-L8XX-CD1-SVPD2-U 1500 12.8 116.7

Full Frost (LW) Standard 4 ft. 4SWLED-LD4-20SL-LW-UNV-L8XX-CD1-SVPD2-U 2000 17.6 113.6

Full Frost (LW) Standard 4 ft. 4SWLED-LD4-28SL-LW-UNV-L8XX-CD1-SVPD2-U 2800 25.6 109.6

Full Frost (LW) Standard 4 ft. 4SWLED-LD4-32SL-LW-UNV-L8XX-CD1-SVPD2-U 3200 30 101.7

Full Frost (LW) Standard 4 ft. 4SWLED-LD4-36SL-LW-UNV-L8XX-CD1-SVPD2-U 3600 35.2 102.1

Full Frost (LW) Standard 4 ft. 4SWLED-LD4-40SL-LW-UNV-L8XX-CD1-SVPD2-U 4000 40.4 99.1

Full Frost (LW) High 4 ft. 4SWLED-LD4-44HL-LW-UNV-L8XX-CD1-SVPD2-U 4400 39.2 112.2

Full Frost (LW) High 4 ft. 4SWLED-LD4-48HL-LW-UNV-L8XX-CD1-SVPD2-U 4800 43.3 110.9

Full Frost (LW) High 4 ft. 4SWLED-LD4-52HL-LW-UNV-L8XX-CD2-SVPD2-U 5200 46.8 111.0

Full Frost (LW) High 4 ft. 4SWLED-LD4-56HL-LW-UNV-L8XX-CD2-SVPD2-U 5600 51.1 109.6

Full Frost (LW) High 4 ft. 4SWLED-LD4-60HL-LW-UNV-L8XX-CD2-SVPD2-U 6000 55.5 108.1

Full Frost (LW) High 4 ft. 4SWLED-LD4-64HL-LW-UNV-L8XX-CD2-SVPD2-U 6400 60 106.7

Full Frost (LW) High 4 ft. 4SWLED-LD4-72HL-LW-UNV-L8XX-CD2-SVPD2-U 7200 69 104.3

WATTAGE

Specifications and dimensions subject to change without notice.

Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting

SWLED

Series (13)

SWLED=LED Surface and Wall

S A M P L E N U M B E R : 4 S W L E D - L D 4 - 4 0 S L - L W - U N V - L 8 4 0 - C D 1 - S V P D 2 - U

LED TypeLD4=LED 4.0

LED Lumens Output (2)

8SL=800 (3)

16SL=1600 (3)

20SL=200024HL=2400 (3)

28HL=2800 (3)

28SL=2800 (4)

32SL=320036SL=360040SL=400044HL=440048HL=480052HL=5200 (12)

56HL=5600 (12)

60HL=6000 (12)

64HL=6400 (12)

67HL=6700 (12), (16)

72HL=7200 (12), (16)

78HL=7800 (12), (16)

80HL=8000 (12), (17)

Voltage347V=347 Volt (11)

480V=480 Volt (11)

UNV=UniversalVoltage 120-277 (1)

UNC=UniversalVoltage347/480 (4), (11)

Driver TypeCD=0-10V Dimming DriverHCD=0-10V Dimming Driver(1% - 100% Dimming) (11)

SD=Step-dim Driver (19), (20)

5LTD=Fifth Light (DALI) Driver

Number of Drivers1=1 Driver2=2 Drivers

OpticLC=Clear Lens LN=Semi-Frost Lens - Narrow LW=Full Frost Lens - Wide

Length2=2 ft. Length4=4 ft. Length

NOTES: (1) Not available when specifying emergencies, voltage must be specific. (2) Nominal lumen output. (3) 2 ft. model. (4) Only available in 4 ft. models. (5) With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. (6) For mounting heights up to 8 ft. (7) For mounting heights up to 30 ft. (8) For mounting heights up to 12 ft. (9) Integral EL battery pack is rated for 35°C. (10) Product configuration meet ADA. (11) Consult factory. (12) Currently not DLC listed, consult factory. (13) DesignLights Consortium™ Qualified and classified for DLC Standard (some models are not DLC qualified), refer to www.design-lights.org for details. (14) For wall mount applications. (15) For use with CD driver only. (16) Lumen value with LN (30% Frost lens). (17) Lumen value with LC (Clear lens). (18) Used to transfer fixture to secondary power source for life-safety operation. When used with a dimming fixture, two devices are required to ensure control is disabled while operating under emergency power. (19) 4 ft. model only. (20) 4000 and above.

Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information.

Options

Emergency (4), (9)

EL7W=7-watt, 120V-277V emergency battery pack installed (5)

EL14W=14-watt 120V-277V emergency battery pack installed (5)

GTD2=Bodine Generator Transfer Device (18)

ETS2=IOTA Emergency Transfer Switch (18)

CCTL835=3500KL840=4000KL850=5000K

Occupancy SensorSVPD1=Integrated occupancyand daylight dimming sensor,500 sq. ft. coverage (6), (8), (10), (15)

SVPD2=Integrated occupancy anddaylight dimming sensor,900 sq. ft. coverage (8), (14), (15)

SVPD3=Integrated occupancy anddaylight dimming sensor,1200 sq. ft. coverage (7), (15)

PackagingU=Unit Pack

A C C E S S O R I E S

(Order Separately)SCF=Fixed Stem Set (Specify Length)SCS=Swivel Stem Set (Specify Length)SCA=Adjustable 48" Stem SetA1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 Per Fixture) ISHH-01=Programming Remote for Integrated SensorISHH-02=Personal Control Remote for Integrated Sensor

ORDERING INFORMATION

4SWLED-LD4-40SL-LW-UNV-L835-CD1

Electronic Driver

Linear LED 3500K

Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.2 x mounting height

Lumens: 4087

Input Watts: 42.5W

Effi cacy: 96.2 lm/W

Test Report: 4SWLED-LD4-40SL-LW-UNV-L835-CD1.IES

051015202530354045505560657075808590

C a n d l e p owe r

Angle Along II 45° Across ⊥

1194 1194 11941203 1188 11731184 1159 11421153 1123 11101110 1080 10741058 1032 1031996 978 983926 918 933849 855 878766 786 816678 713 754588 639 690495 564 626400 491 563302 419 503207 352 445125 291 39055 236 3374 188 285

C o e ffi c i e n t s o f U t i l i z a t i o n

Effective fl oor cavity refl ectance 20%

rc 80% 70% 50% 30% 10% 0%rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR0123456789

10

117 117 117 117 113 113 113 113 106 106 106 100 100 100 94 94 94 91105 99 94 90 101 96 91 87 90 86 83 85 82 79 80 77 75 7295 85 78 71 91 83 76 70 78 72 67 73 68 64 69 65 61 5986 74 66 59 82 72 64 58 68 61 55 64 58 53 60 56 51 4978 66 56 49 75 64 55 49 60 53 47 57 50 45 54 48 44 4172 58 49 42 69 57 48 42 54 46 40 51 44 39 48 42 38 3566 53 43 37 64 51 42 36 48 41 35 46 39 34 44 38 33 3161 48 39 32 59 46 38 32 44 36 31 42 35 30 40 34 29 2757 43 35 29 55 42 34 28 40 33 28 38 32 27 36 31 26 2453 40 31 26 51 39 31 25 37 30 25 35 29 24 34 28 24 2250 37 29 23 48 36 28 23 34 27 22 33 26 22 31 26 21 20

Z o n a l L u m e n S u m m a r y

Zone Lumens % Fixture0-30

0-40

0-60

0-90

0-180

905 22.1

1480 36.2

2656 65.0

3738 91.5

4087 100.0

450

0˚ 15˚ 30˚

45˚

60˚

75˚

90˚

900

1350

PHOTOMETRICS

ADF1423522016-09-27 07:58:10

Catalog No. Wt.

2SWLED-LD4 6 lbs.

4SWLED-LD4 12 lbs.

SHIPPING DATA

Specifications and dimensions subject to change without notice.

Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting

The SWLED with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The SWLED delivers superior lighting with integrated occupancy and daylighting controls.

Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the SWLED delivers automatic ON to an energy saving light level, ensuring lighting is turned OFF when the space is unoccupied.

The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method.

Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02) provides code compliant manual raise, lower, ON, OFF control.

The SWLED with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings.

How it works:

• As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level.

• Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 20 minutes).

• If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable light level is typically half of the occupied daylight level.

• At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting.

Coverage Patterns next page

100

0

Lig

ht

Leve

l (DO)Daylight Level

(DO)Daylight Level

Timeout Value

OccupiedUnoccupiedOccupiedUnoccupied

Energy SavingsOpportunities

(DU)Unoccupied Level

Target light level default: 500 lux at 8 ft.

INTEGRATED SENSOR

SWLED

ADF1423522016-09-27 07:58:10

Specifications and dimensions subject to change without notice.

Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting

CL

Top View

9.1m[30 ft.]

6.1m[20 ft.]

4.5m[15 ft.]

3m[10 ft.]

1.5m[5 ft.]

0

1.5m[5 ft.]

3m[10 ft.]4.5m

[15 ft.]

6.1m[20 ft.]

9.1m[30 ft.]

Side View

0

2.4m[8 ft.]

6.1m[20 ft.]

4.5m[15 ft.]

3m[10 ft.]

1.5m[5 ft.]

0 9.1m[30 ft.]

6.1m[20 ft.]

4.5m[15 ft.]

3m[10 ft.]

1.5m[5 ft.]

Side View0

6.1m[20 ft.]

9.1m[30 ft.]

12.2m[40 ft.]

9.1m[30 ft.]

6.1m[20 ft.]

3m[10 ft.]

0 12.2m[40 ft.]

9.1m[30 ft.]

6.1m[20 ft.]

3m[10 ft.]

SVPD2 Coverage Pattern

SVPD3 Coverage Pattern

CL

Top View Side View

4m[12 ft.]

4m[12 ft.]

0m[0 ft.]

Coverage

Major Motion

3.3m[10 ft.]

0m[0 ft.]

0m[0 ft.]

4m[12 ft.]

4m[12 ft.]

Reccomended Mounting Height 8–12 ft.

SVPD1 Coverage Pattern

Optional RemoteControls

ISHH-01 Programming Remote

Programming Remote

ISHH-01

To Set Output

1. Raise, Lower or Press Min.

50, 75, Max.

2. To save press SET

3. Select Occ or Un Occ

Raise/Lower

TimeOut5

10

15

20

HI

LO

ES

SET

Occ

50

MIN

UnOcc

MAX

75

Personal Remote

ISHH-02

Raise/Lower

SCENEMAX

75

50

MIN

UnOcc

ES

OccTo Select Scenes

Press the SCENE button.

The lighti ng wi ll adjust to

stored light levels. .

ISHH-02 Personal Control Remote

SENSOR DETAILS - SWLED

SWLED

ADF1423522016-09-27 07:58:10