conquest firespray fire rated ductwork warren michigan

18
Conquest FireSpray Fire Rated Ductwork Warren Michigan Warren Michigan

Upload: beverly-henry

Post on 21-Dec-2015

220 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Conquest FireSprayFire Rated Ductwork

Warren Michigan Warren Michigan

Page 2: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Manufacturing Capabilities

• Two fabrication facilities (130,000 + sq. ft.)• History of large projects (Ohio State Univ.)• Full 3D modeling & project management staff• All styles of duct (spiral, flat oval, rectangular,

welded)

Page 3: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Enclosure by Design:

• In the USA the predominate method for fire protection is subdivided into categories:• Compartments• Detection• Alarm/Notification• Evacuation• Sprinklers• Smoke Removal

Page 4: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Enclosure by Design:

• What about smoke removal?• Are we engineering a smoke removal

system tested for that use?• Or are we utilizing the existing

systems to perform a function they are not tested to provide?

Page 5: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Enclosure by Design:

• According to SMACNA and the corresponding British standard ventilation and exhaust ductwork have no tested fire resistive standard in their respective designs.

• That means the SMACNA tables are not designed to include a fire rating.

• HVAC systems with openings will introduce hot gasses into the duct that is not designed to handle.

Page 6: Conquest FireSpray Fire Rated Ductwork Warren Michigan

What is Fire Rated Ductwork

• Search of 2009 IBC and 2009 IMC• No mention in the code of Fire

Resistive Ductwork• How do we handle Fire Resistive

Ductwork?

Page 7: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Enclosure by Design:

• There is no USA (ASTM) test today that recognizes fire rated duct systems.

• There is however an International Standard ISO 6944 (1985 and 2008) .

Page 8: Conquest FireSpray Fire Rated Ductwork Warren Michigan

ISO 6944

• ISO 6944• Test Fire Resistive performance of

ductwork.• Test follows time temperature

curve in E119• Developed in EU for Fire Duct and

Smoke Extraction Ductwork.

Page 9: Conquest FireSpray Fire Rated Ductwork Warren Michigan

ISO 6944

• ISO 6944• Tests Ductwork for 2 conditions

• Fire inside a duct Type B• Fire outside a duct Type A

• Conditions of the Test• Integrity• Stability• Insulation

Page 10: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Type A and Type B Duct(Wrap is only rated for Type A)

THE DUCT IS THE ENCLOSURE

Page 11: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Alternate Systems Drywall Enclosures

• Conventional Shaft Riser with 2 hour Rated Gypsum Enclosure (3 layers)

• Fire dampers must be in wall

Page 12: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Firewrap Insulated Duct• Insulated Fire Wrap•1 and 2 hr protection•Type A only (fire outside

the duct)•Upgraded Duct•Upgraded Supports•Multiple Trades

Alt. Wrap Enclosures

Page 13: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Classified for up to 2 & 4 hours as a smoke and fire duct (ISO-6944) and complies with NFPA 96

Fire Rated DuctTested and Classified by UL &

ETL

Page 14: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Fire Rated Ductwork

• US Codes are evolving to accept a duct as an enclosure.

• ASTM E2816-11 Metallic Fire Resistive Duct Enclosures.

• Passed Committee July 2011• ICC Evaluation Services

• Acceptance Criteria November 2011

Page 15: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Fire Rated Ductwork & Metalic Enclosure

• Test Procedure based on ISO 6944 (2008) standard• Tests Ductwork for both conditions

• Horizontal Condition A, C• Vertical Condition B, D

• Test for fire inside and outside the duct. You cannot guarantee a fire will remain outside the duct.

Page 16: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Fire Rated Ductwork & Metalic Enclosure

• Test Procedure based on ISO 6944 (2008) standard• Conditions of the Test

• Integrity• Stability• Insulation

• Test includes Hangers, Supports and Firestop conditions.

• Inserts and structural connections not inlcuded.

Page 17: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Grease Duct

• June 2012• ICC ES issued Acceptance Criteria

AC101.2 • Recognized galvanized duct without

porcelain coating.• Tested to conditions of UL1978

except for those related to coating.• Field enclosure

Page 18: Conquest FireSpray Fire Rated Ductwork Warren Michigan

Conquest FireSpray