conceal area
DESCRIPTION
Conceal AreaTRANSCRIPT
CONCEAL AREA
Assumptions :-
Given high pressure water hose jet power flowrate is 38 m/s
From the layout provided:
Total Area = 20m x 8m =160m²
Assume Covered Area for closed zone = 5m x 2m =10m²
Total Area Flowrate; Q = Total Covered Area x No. Hose x Hose Flowrate = (10m x 1 x 38 m/s)/1000 L/sec = 0.38 L/sec
Maximum Capacity = 0.38 L/sec x 20% = 0.456 L/sec
=15 GPM (nearest available sizing)
Recommended AEP Oil Interceptor Sizing = 15 GPM
Recommended AEP Oil Collection Tank Sizing = 150 L