COMPUTER SIMULATION OF BLOOD FLOW
WITH COMPLIANT WALLS
2004-2010 ITC Software All rights reserved.
![Page 2: COMPUTER SIMULATION OF BLOOD FLOW WITH COMPLIANT WALLS 2004-2010 ITC Software All rights reserved](https://reader036.vdocuments.mx/reader036/viewer/2022083009/5697bfd21a28abf838cabd78/html5/thumbnails/2.jpg)
THE FLUID-STRUCTURE INTERACTION ALGORITHM(LOOSE COUPLING)
CFD Solver
Geometry of interface surfaces
and velocity
Load transfer
INTERFACE
Surface tracking
Loads
CSD Solver
Information exchange for the coupled fluid-structure interaction problem
![Page 3: COMPUTER SIMULATION OF BLOOD FLOW WITH COMPLIANT WALLS 2004-2010 ITC Software All rights reserved](https://reader036.vdocuments.mx/reader036/viewer/2022083009/5697bfd21a28abf838cabd78/html5/thumbnails/3.jpg)
Finite element mesh for fluid domain of the carotid artery bifurcation
Blood density =1.05 g/cm3
Kinematic viscosity =0.035 cm2/sRe=300
![Page 4: COMPUTER SIMULATION OF BLOOD FLOW WITH COMPLIANT WALLS 2004-2010 ITC Software All rights reserved](https://reader036.vdocuments.mx/reader036/viewer/2022083009/5697bfd21a28abf838cabd78/html5/thumbnails/4.jpg)
Finite element mesh for solid domain (shells) of the carotid artery bifurcation Young’s modulus E=3.61 x106g/s2cm
Density of wall =1.1 g/cm3
Thickness:common carotid 0.031 cm distal segment internal carotid 0.022cm external carotid 0.020 cm Geometrical non-linearity (Updated Lagrangian)
![Page 5: COMPUTER SIMULATION OF BLOOD FLOW WITH COMPLIANT WALLS 2004-2010 ITC Software All rights reserved](https://reader036.vdocuments.mx/reader036/viewer/2022083009/5697bfd21a28abf838cabd78/html5/thumbnails/5.jpg)
Velocity distribution for t/tp=0.1
![Page 6: COMPUTER SIMULATION OF BLOOD FLOW WITH COMPLIANT WALLS 2004-2010 ITC Software All rights reserved](https://reader036.vdocuments.mx/reader036/viewer/2022083009/5697bfd21a28abf838cabd78/html5/thumbnails/6.jpg)
Effective stress distribution at the carotid bifurcation walls, t/tp=0.325
![Page 7: COMPUTER SIMULATION OF BLOOD FLOW WITH COMPLIANT WALLS 2004-2010 ITC Software All rights reserved](https://reader036.vdocuments.mx/reader036/viewer/2022083009/5697bfd21a28abf838cabd78/html5/thumbnails/7.jpg)
Wall shear stress field at t/tp=0.1 (deformable walls)
![Page 8: COMPUTER SIMULATION OF BLOOD FLOW WITH COMPLIANT WALLS 2004-2010 ITC Software All rights reserved](https://reader036.vdocuments.mx/reader036/viewer/2022083009/5697bfd21a28abf838cabd78/html5/thumbnails/8.jpg)
Blood velocity field in the carotid artery bifurcation for t/tp=0.1
![Page 9: COMPUTER SIMULATION OF BLOOD FLOW WITH COMPLIANT WALLS 2004-2010 ITC Software All rights reserved](https://reader036.vdocuments.mx/reader036/viewer/2022083009/5697bfd21a28abf838cabd78/html5/thumbnails/9.jpg)
ANIMATION
![Page 10: COMPUTER SIMULATION OF BLOOD FLOW WITH COMPLIANT WALLS 2004-2010 ITC Software All rights reserved](https://reader036.vdocuments.mx/reader036/viewer/2022083009/5697bfd21a28abf838cabd78/html5/thumbnails/10.jpg)
We hope you enjoyed our presentation !
ITC Software
Tel.: +1 978 287 4855
[email protected]://www.itcsoftware.com
We hope you enjoyed our presentation !
ITC Software
Tel.: +1 978 287 4855
[email protected]://www.itcsoftware.com