compatibility rolling stock – track circuits: test...
TRANSCRIPT
emkamatikCompatibility rolling stock – track circuits:
Test Campaigns and Results
(Presentation shown at RAILCOM
final conference, Paris, 21.4.2009)
Markus Lerjen, Markus Meyer
(emkamatik GmbH, on an SBB contract in RAILCOM project)
emkamatik
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 2
emkamatik Test campaigns
Tests in different countries:
• Germany: ICE-S (test train for Railcom)
• Switzerland: Re 460 (scheduled IC train)
• France: TGV DASYE (test train for Railcom)
• Italy: Several trains (test trains for Railcom)
• Czech Rep. / Poland: CD 163 (scheduled trains)
Total more than 10‘000 km of test runs
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 3
emkamatik Test Setup
Measurement setup:
• line voltage at pantograph
• primary current of vehicle
• (speed, position)
Sampling rate 50 kHz
Offline: Bandpass-filtering and
evaluation for 324 frequencies
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 4
emkamatik SBB: Measurements with loco Re 460
RH
WF
BR
LBT
SP
BN
OLZUE Romanshorn:
far from substation
Weinfelden:
GTW trains, low traffic
Zürich:
largest station,
many trainsOlten:
FLIRT trains
Bern:
NINA trains
Spiez:
close to Wimmis
converter station
Lötschberg Base Tunnel:
extreme cabling,
low resonancesBrig:
close to Simplon tunnel
(strong 132-kV network resonance)
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 5
emkamatik SBB: Measurements with loco Re 460
Re 460:
• Transformer only
(no filter or cable)
15 kV / 16.7 Hz
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 6
emkamatik SBB: Voltages at different locations
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 7
emkamatik SBB: Comparison
voltages / currents at 8 different locations (max. values)
U
Inearly no differences
very large differences
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 8
emkamatik DB: Measurements with ICE-S
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 9
emkamatik DB: Results for different locations
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 10
emkamatikvoltages / currents at different locations (max. values)
DB: Comparison
U
Idifferences as well – why?
large differences
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 11
emkamatik DB: Measurements with ICE-S
ICE-S:
• Transformer
+ input Filter
+ some cable
Picture: Railfaneurope.net/Christoph Schmitz
15 kV / 16.7 Hz
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 12
emkamatik SNCF: Measurements with TGV Dasye
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 13
emkamatikSNCF: Results for different locations (AC)
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 14
emkamatik SNCF: Measurements with TGV Dasye
TGV Dasye:
• Transformer
+ roof cable to
2nd power head
25 kV / 50 Hz
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 15
emkamatik TGV Dasye: AC Measurement setup
Allows comparison with / without roof cable for AC
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 16
emkamatikTGV Dasye: Voltage, Current own Power Head (AC)
U
I
voltages / currents at different locations (max. values)
nearly no difference
very large differences
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 17
emkamatikTGV Dasye: Current own and 2nd Power Head (AC)
Own power head (without cable):
2nd power head (with cable):
I
I more differences
very small differences
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 18
emkamatikSNCF: Results for different locations (DC 1500 V)
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 19
emkamatik SNCF: Voltage, Current (DC 1500 V)
U
I
voltages / currents at different locations (max. values)
Substation harmonics dominating
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 20
emkamatik PKP: Measurements with CD 163
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 21
emkamatik PKP: Measurements with CD 163
CD 163:
• Thyristor chopper
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 22
emkamatikPKP: Results for different locations (DC 3000 V)
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 23
emkamatik PKP: Comparison (DC 3000 V)
U
I
voltages / currents at different locations (max. values)
Substation harmonics dominating
Compatibility rolling stock – track circuits: Test Campaigns and Results (Paris 21.4.2009) 24
emkamatik Input to TS 50238–2
Results of the test campaigns are included in the
TS 50238–2 :
• Infrastructure requirements for measurements
• Special conditions or AC trains with capacitive
input impedance
• Interface voltages in
Annex B (Informative):