compact - wydział farmaceutycznylc-ms/ms. now, the benefits of full-scan data and precise mass...

8
LC-MS/MS Innovation with Integrity Instant expertise in accurate mass LC-MS/MS compact

Upload: others

Post on 24-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

  • LC-MS/MSInnovation with Integrity

    Instant expertise in accurate mass LC-MS/MS

    compact

    Bru

    ker

    Dal

    toni

    cs is

    con

    tinua

    lly im

    prov

    ing

    its p

    rodu

    cts

    and

    rese

    rves

    the

    rig

    ht

    to c

    hang

    e sp

    ecifi

    catio

    ns w

    ithou

    t no

    tice.

    © B

    DA

    L 0

    3-2

    013,

    181

    626

    0

  • Research-Grade Technology Meets High Productivity

    Instant expertise

    You expect the fullest possible insight into your sample. compact delivers the highest quality of results without compromise. All specified performance parameters simultaneously delivered in a single run with no need for tuning or optimization is what makes compact unique.

    Bruker‘s „one-shot analysis“ philosophy is embodied in compact, accelerating productivity by enabling every analyst to deliver expert calibre results even on the first run.

    compact is teamed with world leading application solution software. Your expert partner, whatever your challenge. Synthetic chemistry confirmation, advanced screening and identification, proteomics and metabolomics, or intact protein and biopharmaceutical analysis compact delivers instant expertise to your laboratory.

    The Ultra-High Resolution (UHR) TOF technology pioneered by Bruker sets new standards and expectations as to what can be achieved using accurate mass LC-MS/MS.

    The power of technology demanded for research applications is now available in a com-pact, robust and economic bench-top system. Research-grade technology applied to every routine analytical task. The new Bruker compact QqTOF features:

    • 50 GBit/sec sampling technology maintain-ing full specification resolution even during ultrafast chromatography

    • Increased dynamic range for definitive trace analysis from complex, high-background matrices

    • Low picogram sensitivity to rival the best triple-quadrupole sensitivity while delivering full scan, precise mass data

    • Superior 1 ppm mass accuracy ensured by automated calibration

  • Engineered for Dependable Precision

    Optimize your LCMS methods without compromising: compact™ delivers all specified performance parameters simultaneously to solve your analytical challenges.

    Full Sensitivity Resolution – Having to choose between resolution and sen-sitivity on other instruments restricts depth to which you can understand your sample.

    Enhanced dynamic range during real LC time scales – Greatly increased robustness to sample variation allowing reduced sample pretreatment especially desirable in high throughput quantitative applications.

    One shot plug & play acquisition with triple-quad standard sensitivity –Ensuring qualitative and quantitative results in one LC run with fastest time-to-success.

    Let the compact™ achieve your goals in:

    Synthetic chemistry support Forensics and doping control Drug metabolite, degradant and

    impurity identification and quantitation Biomarker discovery and validation in

    proteomics and metabolomics Intact protein analysis and characteriza-

    tion of biopharmaceuticals

    Flight Tube with in-flight focussing for full sensitivity resolution

    New 10bit ADC digitizer

    High Transmission CID Cell

    Quadrupole

    Patented Dual Ion Funnel

    ESI Source

    Dual Stage Reflector

    Don‘t accept compromise – Go for Instant Expertise!

    There is more to successful analysis than hitting the mark on one performance parameter at a time.

  • 5 orders of magnitude intrascan dynamic range at LC speed

    Advantages of new compact™ Time-of-Flight detection system

    Very fast detection and digitizing techno-logy is key to maintaining full resolution at all acquisition speeds and provide high dynamic range to detect the smallest peaks in the presence of high-abundance background matrix. The new 10bit ADC digitizer also delivers Bruker’s renowned true isotopic pattern, an essential feature for de-novo chemical identification using Smartformula3D™.

    Ultimate sensitivity

    Groundbreaking sensitivity improvements bring compact’s trace analysis capabi-lities to levels usually associated only with targeted assays on triple quadrupole LC-MS/MS. Now, the benefits of full-scan data and precise mass confirmation can be brought to all routine screening assays.

    The Key to Sensitivity and High Dynamic Range

    Repetitive injection of reserpine displayed as BPC of m/z 609

    11 12 13 14 15 Time [min]0.0

    0.5

    1.0

    1.5

    4x10Intens.

    msSensitivity_DionexLC_QT3-pp03_HESI_000002.d: BPC 609.2807±0.008 +All MS

    100 fg absolute reserpine withionbooster sourceS/N > 100:1 RMS

    Intensity ratio = 7 155 285 / 46 = 1.6 x 105 @ 1Hz acquisition speed

    195.0878

    217.0696

    233.0436

    +MS, 4.2-4.3min #247-256

    0

    2

    4

    6

    6x10Intens.

    0 25 50 75 100 125 150 175 200 225 m/z

    Caffeine 0.6ppm I = 7 155 285cts

    90.0550

    +MS, 4.2-4.3min #247-256

    0

    10

    20

    30

    40

    50

    Intens.

    86 88 90 92 94 96m/z

    Alanine 0.5ppm I = 46ctsS/N > 8:1

  • The Key to Sensitivity and High Dynamic Range

    Your Partner in Chemistry Support

    Your in-lab, publication-ready facility for synthetic chemical confirmation delivered and managed!

    Compass OpenAccess™ provides an automated walk-up accurate-mass system for chemical formula identification, confirmation and general LC-MS measurements. The client-server based software supports a wide variety of workflows especially for synthetic and medicinal chemists with no MS expertise required. Immediate, publication quality accurate mass data reports are automatically emailed to the user, transmitted to e-labbook and archived. Compass OpenAccess has full group facility management tools vastly reducing the management burden of a multi-user core facility, whether in industry or university settings.

    SmartFormula determination

    Three dimensions of information simultaneously raise your analytical tasks to unrivaled heights of confidence:

    Measure with superior accurate mass Validate with True Isotopic Pattern

    (TIP) analysis Also benefit from accurate mass

    and TIP in analysis of fragments in MS/MS mode

    Mass accuracy, chemical knowledge and SmartFormula 3DTM clearly limit the number of possible formulae in molecular formula generation: for confident deter-mination of the elemental composition of a given peak.

    Compass OpenAccess job results

    # possible formulae

    Mass Accuracyseveral ppm accuracy

    plus Chemical Expertiseadditional confidence

    plus SmartFormula (Mass Accuracy+TIP)

    sub-ppm confidence

    plus SmartFormula3D (fragments-based TIP)unambiguous formula ID

    numerous

    medium

    few

    single

  • One Run Discovery and Validation of ...

    5 orders of magnitude intrascan dynamic range at LC speedMulti-target screening on 10 ppb level

    hrEIC of m/z 72.0444∆m/z = 0.5 ppm

    High resolution Extracted Ion Chromatogram (hrEIC) identifying 60 pesticides in a single LC-TOF run. All analytes across the entire mass range of 70 m/z up to 900 m/z are detected with highest sensitivity maintaining full resolution at U-HPLC speed. The new CID cell with uncompromised mass transfer and sensitivity allows for small molecule screening, confirmation and quantitation in a single LC-TOF run.

    Confirmation of molecular formula with instant accurate mass and isotopic fidelity

    Measured (top) against theoretical spectrum (bottom) of Penconazole (C13H15Cl2N3) out of the same data set showing a perfect fit of isotopic ratios and spacing. SmartFormula™ does confirm the identification in spite of matrix background signals.

    hrEIC of m/z 890.5267∆m/z = 1.7 ppm

  • One Run Discovery and Validation of ... Biomarkers and Small Molecules

    In-depth identification analysis of complex proteomics samples

    LC auto MS/MS survey plot: A 3µg digest of human Hela cells was separated on a 50 cm column with 4 h gradient on a compact LC-MSMS system. The instrument was operated with new IDAS™ (Intensity Dependent Acquisition Speed) parent selection and acquisition strategies to obtain optimum results independent from sample complexity or amount (read Bruker App-Note LCMS-81 for more details about IDAS). This strategy enables a higher quality of acquired spectra (> 50% peptide identification rate) while the corresponding method can deliver optimum results from any samples with no adjustments.

    IDAS: Illustration showing an example of time cycle handling with the Independent Data Acquisition Strategy: the number of precur-sors is chosen dynamically to maintain the constant cycle time and the MS/MS spectra rate is adapted to each precursor intensity.

    400

    600

    800

    1000

    1200

    1400

    m/z

    25 50 75 100 125 150 175 200 225 Time [min]

    ID more than 2570 proteins with FDR < 1%

    One Method Fitting All Samples

    Sample amount 3µg 20ng

    Gradient 4h 90min

    ID @ 1% FDR 2575 631

    IDAS

    New parent acquisition / selection

    Intensity Dependant Acquisition Strategy

    20Hz 2Hz

    MSMS spectra rate

    0.00

    1.00

    2.00

    3.00

    4.00

    5.00

    1 2 3 4

    MS MS MS MS

    40 MSMS

    39 MSMS

    27 MSMS

    30 MSMS

    Aut

    oMS

    MS

    cyc

    le ti

    me

    [s]

    AutoMSMS cycles18 19

    Introducing new universal acquisition strategies – best results run over run

  • Bru

    ker

    Dal

    toni

    cs is

    con

    tinua

    lly im

    prov

    ing

    its p

    rodu

    cts

    and

    rese

    rves

    the

    rig

    ht

    to c

    hang

    e sp

    ecifi

    catio

    ns w

    ithou

    t no

    tice.

    © B

    DA

    L 0

    3-2

    013,

    181

    626

    0

    For research use only. Not for use in diagnostic procedures.

    Bruker Daltonik GmbH

    Bremen · GermanyPhone +49 (0)421-2205-0 Fax +49 (0)421-2205-103 [email protected]

    Bruker Daltonics Inc.

    Billerica, MA · USA Fremont, CA · USAPhone +1 (978) 663-3660 Phone +1 (510) 683-4300 Fax +1 (978) 667-5993 Fax +1 (510) 490-6586 [email protected] [email protected]

    www.bruker.com/compact

    Source Options

    Wide choice of ionization and coupling techniques for a broad range of sampling including insoluble compounds:

    IonBooster source GC-MS coupling APCI II (atmospheric pressure chemical ionization) source Direct probe option for solids APPI II (atmospheric pressure photo ionization) source CE-MS coupling with grounded needle CaptiveSpray NanoElectrospray source CryoSpray source

    LC Options

    Bruker fully supports and integrates a wide range of leading HPLC systems, autosamplers and accessories.

    GC-MS coupling

    Direct probe mounted on an APCI II source

    APPI II source