comfort of hot water - taco - hvac · 2019. 2. 4. · 0011-cf 0011-cf-usk 10 11 14 15 1/25 1/25 1/8...

2
Taco TacoGenie is the Perfect Match. Combining the TacoGenie with a tankless water heater will save your customers energy dollars and preserve warranty longevity. So if you’re going tankless, Go TacoGenie. and a Tankless Water Heater Enjoy the soothing convenience and comfort of hot water

Upload: others

Post on 01-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Taco TacoGenie™ is the PerfectMatch.Combining the TacoGenie with a tankless water heater will save your customers energy dollars and preserve warranty longevity.

    So if you’re going tankless,Go TacoGenie.

    and a TanklessWater Heater

    Enjoy the soothing convenience and

    comfort of hot water

  • CITY WATER SUPPLY COLD WATER LINE

    HOT WATER LINE

    RETURN LINE

    RemoteActivation

    RemoteActivation

    RemoteActivation

    HotWaterSupplyValve

    ColdWater

    SupplyValve

    Motion Sensor orStarter Button

    Activation

    TacoGenie

    ElectronicControls

    HeatSensor Remote

    Receiver

    HotWaterSupplyValve

    ColdWater

    SupplyValve

    TanklessWaterHeater

    TacoGeniefor ReCirc Piping

    TanklessWaterHeater

    CITY WATER SUPPLY COLD WATER LINE

    HOT WATER LINERemoteActivation

    HotWaterSupplyValve

    ColdWater

    SupplyValve

    RemoteActivation

    Motion Sensor orStarter Button

    Activation

    TacoGenie

    ElectronicControls

    HeatSensor

    RemoteReceiver

    TacoGeniefor Standard Piping(Non-ReCirc)

    Taco Inc., 1160 Cranston Street, Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360 Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436

    www.taco-hvac.com

    ProductNumber

    008-CT

    008-CT-USK

    0011-CF

    0011-CF-USK

    10

    11

    14

    15

    1/25

    1/25

    1/8

    1/8

    3250

    3250

    3250

    3250

    115/60/1

    115/60/1

    115/60/1

    115/60/1

    1/2” Male NPT

    1/2” Male NPT, with plumbing kit

    3/4” Shut-o� Flange

    3/4” Shut-o� Flange, with plumbing kit

    ShipWeight

    ConnectionSizes

    MotorVoltage RPM HP

    TacoGenie Water Recirculation System

    ProductNumber

    554-7

    554-8

    554-3

    554-4

    Remote transmitter, receiver kit

    Individual remote transmitter

    Individual starter button

    Motion Sensor Starter Kit

    To start system with wireless remote control

    For wireless remote control at multiple locations

    For hard-wired starter control at multiple locations

    For automatic motion detection start

    Description What it does

    TacoGenie — Accessories

    Standard Plumbing & Distance between tankless waterheater and �xture where TacoGenie is installed

    Re-circulation plumbing AND Square Footage of house

    Over 60 ft.

    Over 2,500 sq. ft.

    Under 60 ft.

    Under 2,500 sq. ft.

    Description 008-CT-USK 0011-CF-USK

    SIZING CHART

    NOTE: Standard plumbing and distance requires that TacoGenie be installed between the hot and cold water line at the most distant hot water location.

    Contact your local Taco wholesaler or local Taco sales representative agency.

    If you’re going tankless...Go TacoGenie™.Leading tankless water heater manufacturers now recommend use of their products with a quality water recirculation system like TacoGenie. In fact, some of those manufacturers may reduce the warranty coverage period if their product is used with a conventional timer-controlled recirculation system. Conventional water recirculation systems fitted with temperature sensors and timers don’t always provide hot water when you want it... that’s why choosing the TacoGenie is always the right choice.

    TacoGenie eliminates the need for a conventional recirculation system, and has been engineered to provide the head pressure needed to overcome the high pressure drops experienced with tankless water heaters.

    TacoGenie delivers hot water by push button or motion sensing – not by temperature sensor or a timer. There are no standby losses, no stack losses and no need for extra storage tanks.

    ©Taco Catalog # 100-49Supercedes: 05/28/14

    Effective Date: 12/08/14Printed in USA

    Standard TacoGenie with USK*(Under Sink Kit) option

    RF Wireless Starter Kit(554-7)

    Motion Sensor(554-4)

    C = TacoGenieT = ThreadedF = FlangedUSK = under sink kit

    *

    *

    Included with USK*